Preview only show first 10 pages with watermark. For full document please download

Gigabit Lx To Tx Tap

   EMBED


Share

Transcript

GigaBit LX to TX Tap Get total traffic visibility for monitoring and security devices by placing Net Optics GigaBit LX to TX Taps on critical network links. GigaBit LX to TX Taps support passive monitoring of GigaBit links at speeds at 1000 Mbps. Technical Specifications: Splitter: Split Ratio: 50/50, 60/40, 70/30 Fiber Type: Corning Singlemode 8.5/125µm For superior reliability, the GigaBit LX to TX Tap features Link Fault Signaling which gives the devices connected to the Tap critical information about link status. If either side of the bi-directional link fails, the Tap immediately communicates the fault to both devices. Wave Length: 1310nm The GibaBit LX to TX Taps establish permanent passive access ports without introducing a point of failure or disturbing other network connections. Without an IP address, monitoring devices are isolated from the network, dramatically reducing their exposure to attacks. However, the monitoring device connected to the Tap still sees all full-duplex traffic, including Layer 1 and Layer 2 errors. Storage Temperature: -10ºC to 70ºC For extra uptime protection, Net Optics GigaBit LX to TX Taps offer redundant power connections. Should the primary power source fail, the Tap automatically switches to the backup power source. Full-duplex monitoring is a snap with supplied cables. All network and monitoring cables necessary for plug-and-play deployment are included. Passive, Secure Technology • Provides passive access at speeds at 1000 Mbps without data stream interference or introducing a point of failure • Link Fault Signaling prevents undetected link failures • Permanent in-line installation without affecting network performance • Passes all full-duplex traffic (including errors) from all layers for comprehensive troubleshooting • No IP address is needed for the Tap or monitoring device, enhancing monitoring security • Redundant power ensures monitoring uptime Ease of Use • • • • • LED indicators show redundant power and link status Front-mounted connectors make installation and operation quick and easy Silk-screened application diagram illustrates all connections for easy deployment Optional 19-inch rack frames hold up to 3 or 12 Taps Tested and compatible with all major manufacturers’ monitoring devices, including protocol analyzers, probes, and intrusion detection/prevention systems Max Insertion Loss: Network Port: 3.7dB, 2.8dB, 2.0dB Operating: Operating Temperature: 0ºC to 40ºC Relative Humidity: 10% min, 95% max, non-condensing Mechanical: Power Supply: Input: 100-240V, 0.5A, 47-63Hz, Output: 12V 1.5A Dimensions: 1.125” high x 6.5” deep x 4.5” wide Fiber Optic Interface: Connector: Class I, eye-safe, laser emitter type. These Class I Lasers conform to the applicable requirements per US 21 CFR (J) and EN 60825-1, also UL 1950 applications. Optical Transmitter Wave Length: 1310nm nominal Output Power: -10 dB min, -3 dB max Optical Reciever Input Sensitivityr: -3 dB min, -20 dB max Cable Interface: Copper Cable Type: 22-24 AWG unshielded twisted pair cable, CAT5/CAT5e Link Distance Supported: 100 meters Connectors: Monitoring Ports: (2) RJ45, 8-pin connectors Network Ports: (2) Singlemode Duplex LC connectors Certifications: Fully RoHS compliant Part Number Description CVT-LX5/GCU CVT-LX4/GCU CVT-LX3/GCU RK-12V2 RK-3V2 GigaBit LX to TX Tap, 50/50 GigaBit LX to TX Tap, 60/40 GigaBit LX to TX Tap, 70/30 Twelve-Slot Rackmount Frame Three-Slot Rackmount Frame All products include a 1 year manufacturer’s warranty. An additional 1 or 2 year extended warranty may also be purchased. 5303 Betsy Ross Drive • Santa Clara, CA 95054 Tel: +1 (408) 737-7777 • www.netoptics.com Net Optics® is a registered trademark of Net Optics, Inc. Copyright 1996-2010 Net Optics, Inc. All rights reserved. Additional company and product names may be trademarks or registered trademarks of the individual companies and are respectfully acknowledged. PUBCVTLXTXD Rev. 1, 06/06 GigaBit SX to TX Tap Net Optics GigaBit SX to TX Tap simplifies connecting GigaBit copper monitoring and security devices to SX fiber network links. Convert SX to TX and tap into the link with one device, reducing cost and complexity at the same time.GigaBit SX to TX Taps support passive monitoring of GigaBit links at speeds at 1000 Mbps. The GibaBit SX to TX Taps establish permanent passive access ports without introducing a point of failure or disturbing other network connections. Without an IP address, monitoring devices are isolated from the network, dramatically reducing their exposure to attacks. However, the monitoring device connected to the Tap still sees all full-duplex traffic, including Layer 1 and Layer 2 errors. For extra uptime protection, Net Optics GigaBit SX to TX Taps offer redundant power connections. Should the primary power source fail, the Tap automatically switches to the backup power source. Full-duplex monitoring is a snap with supplied cables. All network and monitoring cables necessary for plug-and-play deployment are included. Passive, Secure Technology • Provides passive access at speeds at 1000 Mbps without data stream interference or introducing a point of failure • Access SX links with GigaBit copper devices without a separate converter • Permanent in-line installation without affecting network performance • Passes all full-duplex traffic (including errors) from all layers for comprehensive troubleshooting • No IP address is needed for the Tap or monitoring device, enhancing monitoring security • Redundant power ensures monitoring uptime Ease of Use • • • • • • LED indicators show redundant power and link status Front-mounted connectors make installation and operation quick and easy Connectors are perfectly angled to reduce cable strain Silk-screened application diagram illustrates all connections for easy deployment Optional 19-inch rack frames hold up to 3 or 12 Taps Tested and compatible with all major manufacturers’ monitoring devices, including protocol analyzers, probes, and intrusion detection/prevention systems Certifications: Fully RoHS compliant Technical Specifications: Splitter Specifications: Split Ratio: 50/50, 60/40, 70/30 Fiber Type: Corning Multimode 62.5/125µm Wave Length: 850nm Insertion Loss: Network Port: 4.5dB Operating Specifications: Operating Temperature: 0ºC to 40ºC Storage Temperature: -10ºC to 70ºC Relative Humidity: 10% min, 95% max, non-condensing Mechanical Specifications: Power Supply: Input: 100-240V, 0.5A, 47-63Hz, Output: 12V 1.5A -48V DC typical, -36V DC min, -75V DC max Dimensions: 1.125” high x 6.5” deep x 4.5” wide Fiber Optic Interface: Connector: Class I, eye-safe, laser emitter type. These Class I Lasers conform to the applicable requirements per US 21 CFR (J) and EN 60825-1, also UL 1950 applications. Optical Transmitter Wave Length: 850nm nominal Output Power: -9.5 dB min, -4 dB max Optical Reciever Input Sensitivity: 0 dB min, -17 dB max Cable Interface: Copper Cable Type: 22-24 AWG unshielded twisted pair cable, CAT5/CAT5e Link Distance Supported: 100 meters Connectors: Monitoring Ports: (2) RJ45, 8-pin connectors Network Ports: (2) Multimode Duplex LC connectors Part Number Description CVT-SXn*/GCU CVT-SXn*/GCU-48V RK-12V2 RK-3V2 GigaBit SX to TX Tap GigaBit SX to TX Tap -48V DC Twelve-Slot Rackmount Frame Three-Slot Rackmount Frame * “n” is the split ratio where 5 is 50/50, 4 is 60/40, and 3 is 70/30. All products include a 1 year manufacturer’s warranty. An additional 1 or 2 year extended warranty may also be purchased. 5303 Betsy Ross Drive • Santa Clara, CA 95054 Tel: +1 (408) 737-7777 • www.netoptics.com Net Optics® is a registered trademark of Net Optics, Inc. Copyright 1996-2010 Net Optics, Inc. All rights reserved. Additional company and product names may be trademarks or registered trademarks of the individual companies and are respectfully acknowledged. PUBCVTGSXTXD Rev. 1, 06/06