Gir 1002 Pt100 Gir 1002 Ns

   EMBED


Share

Transcript

Digital temperature controller with 2 relays Digital controller for standard signals with 2 relays In accordance with EN50081-1 and EN50082-2 for unrestricted use in residential and industrial areas Microprocessor-2-level controller Pt 100, with min./max. alarm 3-level controller, min./max. value memory, RS485 interface Freely adjustable 2-level controller for standard signal with min./ max. alarm, 3-level contr., min./max. value memory, RS485 interface GIR 1002 Pt100 GIR 1002 NS Specification: Specification: Measuring range: -199,9 ... +650,0 °C (standard) -199,9 ... +999,9 °F (please specify when ordering) Resolution: 0,1 °C Accuracy: ± 0,03 % FS ± 1 digit (at nominal temperature = 25°C) Measuring rate: approx 3 measurements / sec. Linearisation: parameter memorized digitally Sensor: not included (please order separately) see page 94 Pt 100, 4-wire (any probe or cable length possible wihout recalibration). Probes fully interchangeable (any Pt 100 sensors in 2 or 3-wire design existing at customers’ can also be connected, as GIR1002Pt100 is equipped with a digital zero-offset adjustment) Self-diagnosis: permanent self-diagnosis of device to ensure troublefree operation by means of integrated precision reference resistor. Measuring range: -1999 ... +9999 digit, first and last value freely adjustable Resolution: any decimal point possible Measuring rate: approx 3 measurements / sec. (at .../FAST: 40 meas. / sec.) Accuracy (at nominal temperature): ± 0.1% FS ± 1 digit (at .../FAST: ± 0,5 % FS ± 1 digit) Standard signal input: (freely selectable) 0 to 20 mA (Ri=50 Ohm) 0 to 1 V (Ri=30 kOhm) 4 to 20 mA (Ri=50 Ohm) 0 to 10 V (Ri=300 kOhm) 2-, 3- or 4-wire. Other input values or extra high Ri upon request. Power supply for sensor: integrated isolated power supply for measuring transducer: 18 V DC ±5 %, 20 mA. Tare function: (upon request). Please specify when ordering. Self-diagnosis: permanent self-diagnosis to ensure trouble-free operation. Filter: software filter to suppress interference signal. Delay in display approx. 1.5 s. If necessary, filter can be switched off. Min./Max. value memory: both the highest and lowest value recorded during operation can be called up by pressing a button. Fault indication: probe damage, probe short-circuit, values no longer within measuring range. Interface: compatible to RS 485 (up to 16 devices linkable via one 2-wire interface). Connection to RS 232 by means of optional GRS485. Analog output [optional]: 4-20mA, 0-20mA or 0-10V, scale to be selected individually, electrically isolated. Controller configuration: (freely selectable - 9 different types available): Type 0: display Type 3: same as type 2, alarm has to be cleared manually Type 6: same as type 5, alarm has to be cleared Type 1: 3-level controller Type 4: 2-level controller with pre-selectable hysteresis manually Type 2: 2-level controller with min./max. Type 5: same as type 4, in addition min./max. alarm, auto- Type 7: 2-level controller alarm self-clearing matically following set-point value, alarm self-clearing Type 8: 3-level controller with pre-selectable hysteresis Type 9: special type, to customer’s specifications - no adjustments OPTION: additional Min/Max alarm relay: max. 42VDC/AC, 0.5A Setting of set-point value: via front side keyboard (lockable upon request) Control range: can be limited by manufacturer upon request Setting of alarm: via front side keyboard or automatically following Alarm delay: 0 to 99 min., pre-programmed by manufacturer (if you want to set yourself, please specify, too) Hysteresis: digital setting of any value (depending on switch on / switch off values set). Minimum hysteresis: 0.1 °C resp. 1 digit. Relay: 2 volt-free relays , 1 changeover contact and 1 normally-open contact, switching output: 10 A (ohmic load) 250 V 50/60 Hz. (optional 2 changeover contact available). Please specify preferred relay fault position (eg sensor not working): open (standard) or closed. The second relay is principally energised (eg for type 2); in case of alarm (i.e. values above/below min./max. value set) the contact will be broken. Semiconductor relay: (optionally - against upcharge - please order separately) if desired, one or two relays can be taken out to allow control of one or two external semiconductor relays (eg. 50A). Control voltage 12 V DC for external semiconductor relay will then be provided. (refer to options) Display: 4 digit red LED, 13 mm high Front: membrane keyboard IP65. Add. sealing for panel-mounting (option) Housing: standard rack type housing 48 x 96 x 100 mm (H x W x D) Panel cutout: 43 x 90.5 mm (H x W) Clamping terminals: screw-type/plug-in terminals Working temperature: 0 to 50°C (permissible ambient temperature for operation of GIR1002...). If temperatures fall below 0°C, device may however be used for permanent operation (please contact us). Power supply: standard 230 V AC 50/60 Hz, approx. 3 VA, for other voltages please refer to options. Options - against upcharge: FAST: fast sampling (only for GIR1002NS) 12VDC: Power supply: 12VDC 1) 24VDC: Power supply: 24VDC 1) 24VAC: Power supply: 24VAC 115VAC: Power supply: 115VAC AAG020: Analog output 0-20mA 1) (scale freely adjustable), electr. isolated AAG420: Analog output 4-20mA 1) (scale freely adjustable), electr. isolated AAG010: Analog output 0-10V 1) (scale freely adjustable), electr. isolated 1) For analog output with option 12VDC o. 24VDC add. upcharge ALR: additional alarm relais: (for 3-level controllers with alarm) (not possible in addition with analog output or fast measuring option) HLR1: control output for external semiconductor relay 12VDC (instead of relay 1) HLR2: control output for external semiconductor relay 12VDC (instead of relay 1 and 2) 2WREL: 2 Changer (1 x Contact additional fed out as stranded wire) TARA: Tare function (only for GIR1002NS) SWV: Setting of set-point value locked AVE: Alarm delay selectable Accessories: HLR 50A External semiconductor relay, 50A (p.r.t. page 52) GRS 485 interface converter converting RS485 to RS232 (p.r.t. page 44) GRS 485 ISO optically isolated interface converter RS485 to RS232 - with data direction detection (p.r.t. page 44) (for programming your own software we recommend to use the GRS485ISO instead of GRS485) EBS 9M Windows-software 9-channel (p.r.t. page 34) EASYControl Windows-software for recording, monitoring and archiving of values obtained from up to 15 GIA/GIR devices (p.r.t. p. 65) GGD 4896 additional sealing for panel mounting IP65 EAK 36 Unit stickers (black with white text) for 36 different units for lettering of display devices. (Units p.r.t. page 44) Suitable temperature probe for GIR1002Pt100: p.r.t. page 94 Ordering examples: GIR1002Pt100 / 12VDC, AAG420, SWV: GIR1002Pt100 with 12VDC supply, analog output 4-20mA, set value locked GIR1002NS / FAST, 24VAC, ALR, HLR2: GIR1002NS fast measuring option with 24VAC supply, additional alarm relais and two semiconductor relais connections. 45