Torrent GreenHeat
Open vented thermal store providing heating and mains pressure hot water
S U P P L I E R S
T O
T H E
M E R C H A N T
T R A D E
F O R
O V E R
3 5
Y E A R S
The final piece in your renewable energy solution
Torrent Cylinders The ultimate alternative energy cylinder
where you will only get an alternative energy contribution to
The heart of an alternative energy system
the hot water. The new range of Torrent GreenHeat thermal stores offer the opportunity to use the widest range of renewable energy
Homeowners can now choose to combine economical
sources to provide safe, cost effective and environmentally
green energy sources including but not limited to:
friendly domestic heating and hot water, in both open • solar panels
vented and sealed primary configurations.
• wood burning stoves, biomass boilers and other Torrent GreenHeat thermal store offers more options
uncontrolled heat sources
than any other store or cylinder, and is designed to
• air source or ground source heat pumps
reduce heating costs by offering complete flexibility for
• electricity from renewable or low carbon sources
householders to use renewable energy or fossil fuels. If the renewable heat source is insufficient to maintain If the system is configured appropriately the heat from the
the best operating temperature for the store, then the
alternative energy source will be available for both hot water
conventional gas, oil or lpg boiler will be switched on to
AND heating. This is only possible with a thermal store such
boost the store, and switched off when it is no longer
as the Torrent and is not possible with an unvented cylinder
needed.
2
Why use a thermal store? Alternative energy fuel sources are typically low grade, inherently unpredictable and are often available in plentiful supply but not when the heat energy is needed! A thermal store provides the means to harness the energy when it is available for later conversion into both hot water AND heating. The alternative energy feeds into the thermal store which is also the water that circulates around the heating system. This means that the energy available from solar panels or a wood burning stove, for example, can be used to provide energy into the heating circuit to decrease the use of fossil fuel based boilers, and hence reduce household running costs. It is very problematic and inherently unsafe to connect
In-built upgrade potential
wood burning stoves or other uncontrolled heat sources to an unvented cylinder, and not easily possible to combine
The Torrent GreenHeat is available with a full array of
alternative energy heat sources to provide energy to the
tappings so that, for example, a wood burning stove or solar
heating circuit, hence the unique advantage of a thermal
panels can be added as an upgrade to the property at a
store.
later stage and the hot water cylinder will be ready to work with it.
Thermal stores also provide many other benefits including: The new Torrent GreenHeat provides the ability to specify • inherently safe with the cylinder being open vented
exactly what position and which tappings are needed at the
• provides mains pressure hot water
time of order, including optional extras, giving you a fully
• provides both hot water and heating
bespoke cylinder when required.
• no requirement for discharge pipework, negating the requirement for G3
Legionella and scald protection by design The domestic hot water is generated via a plate heat exchanger. As hot water is demanded, it is mains cold water which is instantaneously heated as it passes through the heat exchanger and delivered to the taps. This method of generating the hot water completely removes the risk of legionella. Gledhill’s patented hot water control system goes one step further. Its intelligent controls, in conjunction with the sensors, modulate the speed of the pump drawing water into the heat exchanger from the store. This regulates the temperatures being delivered to the taps or shower, preventing the risk of scalding.
3
Environmental credentials throughout
Water main requirements
The Torrent range is insulated to a very high standard with
The Torrent is a mains pressure hot water system, therefore
our revolutionary insulation across the full range of Torrent
it is important to check and ensure that the performance of
cylinders, which has an industry leading Ozone Depletion
the incoming mains cold water supply is adequate before
Potential (ODP) and Global Warming Potential of zero.
choosing to use it. To achieve the best performance it is recommended that a dynamic pressure of between 2 and
The Torrent cylinders are manufactured from copper, a fully
4 bar is available at the appliance although it will work
recyclable resource, and made at any of our nationwide
adequately at pressures as low as 1.5 bar. A minimum flow
network of super depot manufacturing units local to the
rate of 30 litres/minute is recommended for small properties
customer, meaning we are not shipping a heavy cylinder full
although in properties with more than 1 bathroom the
of fresh air half way around the country! We think this makes
required flow rate should be calculated using the method set
perfect environmental sense and makes the Torrent the
out in British Standard BS6700 or other suitable design guide.
lowest carbon-footprint alternative energy cylinder available in the UK. They are also fully recyclable at the end of their
Building Regulations compliance
extensive working life. In addition, where a copper cylinder is being replaced as part of the installation of a Torrent we
The Torrent range is Building Regulations Part L1 compliant
are willing to take it back and provide a credit for the scrap
for both new build and refurbishment projects. It is also
copper which will then be recycled.
fully compliant with the Hot Water Association (HWA) Performance Specification for Thermal Stores.
4
Torrent Model Selection Guide Primary Energy Source
Immersion Heaters 5
Solar Thermal System
Solid Fuel
Primary Heating System Source 1
Secondary Heating System Source
Torrent GreenHeat OV
Open vented boiler or immersion heaters
2 or 3
No
Yes
Store and / or boiler
n/a
Torrent GreenHeat SP
Sealed primary boiler
1
No
Yes
Boiler only
Store 2,4
Torrent GreenHeat SOL
Open vented and / or sealed primary boiler
1
Yes
Yes
Store and / or boiler
n/a
Torrent GreenHeat HP
Heat pump
1-46
No
Yes
Store and / or heat pump 3
n/a
Torrent GreenHeat HP SOL
Heat pump
1-46
Yes
Yes
Store and / or heat pump 3
n/a
Please note the F&E tank does not come as standard with the unit. Notes: 1 The Primary Energy Source must be sized to heat the thermal store and the heating system. 2 The Auxiliary Central Heating System Output must be no greater than the Auxiliary Energy Sources Input. 3 The Heat Pump supplies the store with water at a lower temperature, therefore the radiators must be sized to account for this. Under-floor heating is the ideal Central Heating System when using a Heat Pump as the primary energy source. 4 If the Sealed Primary Coil is used for Under-floor heating, the heat output of the Under-floor heating is limited by the efficiency of the Coil and the Auxiliary Energy Source Input, which in addition, must be able to keep the Store hot enough for domestic hot water purposes. 5 Immersion heaters on the OV models may be used as the main heat source and will heat the whole cylinder. On all other Torrent models they are back up heat sources or can be used to heat the store if a low-carbon electricity source is available. 6 See installation instructions for further details.
Product selection
Full technical details including typical wiring diagrams are provided in the Torrent GreenHeat Design, Installation and
The model selection guide shown above will allow you
Servicing Instructions. These must be read in conjunction
to choose the model type that is suitable for the heating
with this guide and all installations must comply fully with their
system and energy sources being used. Once you have
requirements as well as the appropriate Building Regulations.
done this refer to the section in this brochure dealing with each model type and also the installation manual for typical details including some system arrangement diagrams and the selection guide for the size of appliance you will need for a range of property types.
The complete range of Torrent cylinder options is explained in this brochure:
The most common energy supply and heating system options are shown, but there are so many more possible combinations.
Page 6
Torrent GreenHeat OV
If you have any queries we will be pleased to comment on any
Page 8
Torrent GreenHeat SP
arrangements you are considering if you forward a detailed
Page 10 Torrent GreenHeat SOL
diagram outlining your proposals.
Page 12 Torrent GreenHeat HP Page 14 Torrent GreenHeat HP SOL
5
Torrent GreenHeat OV
Open vented thermal store providing open vented heating and mains pressure hot water The Torrent GreenHeat OV utilises an open vented boiler and
Electric-only option
/ or direct electric immersion heaters as its primary energy source. The standard configuration comes fitted with a wide
Where no gas or solid fuel source is available, the Torrent
range of tappings, but if not required, any of these can be
GreenHeat OV can be heated by the two 3kW electric
removed, or optional extras added at the time of ordering.
immersion elements. Domestic hot water can be generated from one or both immersion heaters.
One of the benefits of the open vented boiler configuration is that the whole output of the boiler is available to the thermal
It is possible for the central heating to be supplied from the
store, unlike the indirect Sealed Primary (SP) version where the
store but this is only powered by the lowest immersion. It is
output from the boiler is limited by the heat exchanger. This
important to note that the design heat loss, of the rooms to be
will provide an improvement in the operational efficiency of the
heated, must be less than the lowest immersion power. If the
boiler, reducing the primary energy usage and running costs.
design heat loss is greater than this, the heating will need to be supplemented by another heat source. However, it is when a combination of renewable resources are available, that the true
Hot water and heating
benefits of the Torrent GreenHeat OV can be achieved. The Torrent GreenHeat OV provides high-performance mains pressure hot water. The heat energy provided from the primary
If connected to the standard grid then the thermal store is the
heat source and / or solid fuel input is circulated from the
perfect solution to maximise usage of an off peak tariff where
store to the central heating circuit, allowing rapid heat-up of a
arrangements should be made to power the lower immersion
radiator system.
element in order to minimise the running costs.
Open Vent Store Overheat
Plate Heat Exchanger Flow Domestic Hot Water Store Sensor
Immersion Heater Solid Fuel Flow (Optional) Hot Supply
Boiler Flow OV Central Heating Flow
Control Thermostat Cold Mains
Immersion Heater
Cold Feed
Central Heating Return
Plate Heat Exchanger Return
Open Vented Boiler Return
Solid Fuel Return (Optional)
6
Torrent GreenHeat OV showing how the cylinder can utilise numerous heat sources (including optional extras) at the same time
Central heating supplied from store
Mains pressure hot water
Cold mains water
Underfloor heating supplied from store
Multi-fuel stove
Open vented boiler
Torrent GreenHeat OV Technical Specification Description
TGH140-OV
TGH170-OV
TGH210-OV
TGH250-OV
TGH350-OV
Unit height
mm
1219
1449
1414
1654
1874
Unit diameter
mm
530
530
580
580
630
Domestic hot water volume
litres
140
170
210
250
350
litres/ minute
35
35
35
35
35
Bath
1
1
2
2
3
Shower room
-
1
1
2
2
Bed
1-2
2-4
3-4
3-5
3-5
Max. hot water flow rate
Maximum dwelling type
Notes: • • • • •
Please note the diagrams shown include optional extra components. Additional height for F&E tank will need to be allowed if it is to be sited in the same cupboard Vent pipes shown through the side of the feed and expansion tank may not be suitable for all systems. Installers must check suitability. The standard open vented store relies on an F&E (feed & expansion) tank suitably sited above the highest radiator point to provide sufficient head for the system. The feed and expansion tank must be sized to take the water expansion of the whole system (ie. solid fuel boiler, cylinder, open flue boiler and auxiliary heating).
7
Torrent GreenHeat SP
Open vented thermal store providing mains pressure hot water with a sealed heating system The Torrent GreenHeat SP utilises a sealed system boiler as
be limited to the energy input from the solid fuel appliance.
its primary energy source. The standard configuration comes
This sealed primary (SP) model permits the use of a smaller
fitted with a wide range of tappings, but if not required, any of
feed and expansion tank because the main central heating
these can be removed, or optional extras added at the time of
circuit does not need to be catered for. This can make
ordering.
positioning the F&E tank more straightforward.
Hot water and heating
Electric back-up
The Torrent GreenHeat SP provides high-performance mains
An immersion element is provided and it is normally envisaged
pressure hot water.
that this will be used as an emergency electric back-up for hot water and to provide emergency energy to the auxiliary heating
The central heating circuit is normally supplied directly from the
circuit. However, if a low carbon or renewable electricity source
boiler although an auxiliary heating circuit can be connected
is available then this could be connected to the immersion
from the store in which case the solid fuel source will provide
element to provide heat input to the thermal store, decreasing
energy to the auxiliary heating circuit. Obviously, the energy
the use of the fossil fuel boiler and hence reducing running
output that can be provided by the auxiliary heating circuit will
costs.
Open Vent Store Overheat
Plate Heat Exchanger Flow Domestic Hot Water Store Sensor
Solid Fuel Flow (Optional) Hot Supply Central Heating Flow (Optional) Immersion Heater Control Thermostat Sealed Primary Boiler Flow
Cold Mains
Sealed Primary Boiler Return
Cold Feed
Central Heating Return (Optional)
Plate Heat Exchanger Return Solid Fuel Return (Optional)
8
Torrent GreenHeat SP showing how the cylinder can utilise numerous heat sources (including optional extras) at the same time Auxiliary central heating supplied from store limited to heat input provided by auxiliary heat source
Mains pressure hot water
Cold mains water Underfloor heating supplied from store
Multi-fuel stove
Central heating supplied by boiler
Sealed boiler
Sealed system kit
Torrent GreenHeat SP Technical Specification Description
TGH140-SP
TGH170-SP
TGH210-SP
TGH250-SP
TGH350-SP
Unit height
mm
1219
1449
1414
1654
1874
Unit diameter
mm
530
530
580
580
630
Domestic hot water volume
litres
140
170
210
250
350
litres/ minute
35
35
35
35
35
Bath
1
1
2
2
3
Shower room
-
1
1
2
2
Bed
1-2
2-4
3-4
3-5
3-5
Max. hot water flow rate
Maximum dwelling type
Notes: • • • •
Please note the diagrams shown include optional extra components. Additional height for F&E tank will need to be allowed if it is to be sited in the same cupboard Vent pipes shown through the side of the F&E tank may not be suitable for all systems. Installers must check suitability. The F&E tank must be sized to take the water expansion of the whole system (ie. solid fuel boiler, cylinder, open flue boiler and auxiliary heating).
9
Torrent GreenHeat SOL
Solar compatible open vented thermal store providing mains pressure hot water with either an open vented or sealed heating system The Torrent GreenHeat SOL utilises either an open vented
Alternatively, the central heating circuit can be supplied
boiler and / or a sealed system boiler as its primary energy
directly from a sealed system boiler via an optional SP coil,
source. It also has a high-efficiency solar coil to allow the
and an auxiliary heating circuit can be fed from the store.
homeowner to benefit from a wide variety of alternative
In which case both the solar and solid fuel energy can also
energy inputs. The standard configuration comes fitted with a
provide an input to the auxiliary heating circuit.
wide range of tappings, but if not required, any of these can be removed, or optional extras added at the time of ordering.
Electric back-up
Hot water and heating
An immersion element is provided and it is normally envisaged that this will be used as an emergency electric
The Torrent GreenHeat SOL provides high-performance
back-up for hot water and to provide emergency energy
mains pressure hot water.
to the auxiliary heating circuit. However, if a low carbon or renewable electricity source is available then this could be
An open vented boiler can be used to directly heat the store
connected to the immersion element to provide heat input to
so that the energy will be available for both hot water and
the thermal store, decreasing the use of the fossil fuel boiler
auxiliary central heating circuit.
and hence reducing running costs.
Open Vent Store Overheat
Plate Heat Exchanger Flow Domestic Hot Water Store Sensor
Solar Sensor
Open Vented Boiler Flow
Solid Fuel Flow (Optional)
Central Heating Flow
Control Thermostat Hot Supply
Sealed Primary Boiler Flow (Optional)
Sealed Primary Boiler Return (Optional) Central Heating Return
Immersion Heater
Open Vented Boiler Return
Cold Mains
Solid Fuel Return (Optional) Solar Coil Flow Solar Sensor
Cold Feed
Solar Coil Return
Plate Heat Exchanger Return Solid Fuel Return (Optional)
10
Torrent GreenHeat Solar showing how the cylinder can utilise numerous heat sources (including optional extras) at the same time
Sensor circuit Solar controller
Solar pumping station
Expansion vessel
Pressure relief
If using an SP boiler, the auxiliary central heating supplied from the store is limited to the heat input provided by the auxiliary heat source
Mains pressure hot water
Open vented boiler
Multi-fuel stove
Cold mains water
Either an open vented, sealed primary or a combination Sealed boiler of the two boilers can be used
Underfloor heating supplied from store Central heating supplied by boiler
Sealed system kit
Torrent GreenHeat Solar Technical Specification Description
TGH210-SOL
TGH250-SOL
TGH350-SOL
TGH450-SOL
Unit height
mm
1414
1654
1874
1764
Unit diameter
mm
580
580
630
730
Domestic hot water volume
litres
210
250
350
450
Dedicated solar volume 2
litres
60
71
100
128
Max. solar collector area 1
m2
2.40
2.84
4.00
5.12
Solar heat exch. surface area 1
m2
0.27
0.34
0.40
0.54
litres/ minute
35
35
35
35
Bath
1
1
2
3
Shower room
1
2
2
2
Bed
2-4
2-4
3-5
4-6
Max. hot water flow rate
Maximum dwelling type
Notes: 1 To comply with the Building Regulations ADL1 Domestic Heating Compliance Guide. 2 This can be adjusted at the time of specification. • • • •
Please note the diagrams shown include optional extra components. Additional height for F&E tank will need to be allowed if it is to be sited in the same cupboard. Vent pipes shown through the side of the feed and expansion tank may not be suitable for all systems. Installers must check suitability. The standard open vented store relies on an F&E (feed & expansion) tank suitably sited above the highest radiator point to provide sufficient head for the system. As the domestic hot water is at mains pressure, the Torrent GreenHeat Solar itself can be sited anywhere in the property. • Provision is also made within the design for a sealed heating/boiler circuit with the heat exchanger provided which would then operate as a conventional cylinder. Although this would reduce the potential for utilising the solar energy in the HEATING CIRCUIT, it would mean that both the Torrent and the F&E tank can then be sited anywhere in the property, as the F&E is only being used to fill the store with water. • The F&E tank must be sized to take the water expansion of the whole system (ie. solid fuel boiler, cylinder, open flue boiler and auxiliary heating).
11
Torrent GreenHeat HP
Thermal store for use with a heat pump to provide heating and mains pressure hot water Rather than operating with a conventional carbon fuel boiler
of which ensure that less boost is required to achieve an
as the main energy source this appliance has been designed
acceptable hot water temperature at the tap.
to operate with an air or ground source heat pump. However it still provides mains pressure hot water from an open
In fact, the ease with which renewable energy systems such
vented thermal store and enjoys all the other benefits outlined
as wood burning stoves can be connected to a Torrent
previously for the other Torrent GreenHeat appliances.
thermal store means that these are often chosen to provide the boost in preference to electricity. However, separate
The main difference when using a heat pump compared to a
immersions can be fitted to boost both the central heating
conventional boiler is the lower temperatures generated by the
and domestic hot water sections of the thermal store.
heat pump. This can lead to health problems in conventional storage/unvented cylinders with low storage temperatures. For
The standard configuration comes fitted with a wide range of
this reason it is necessary to constantly boost the hot water
tappings, but if not required, any of these can be removed, or
temperature using electricity to meet the Regulations regarding
optional extras added at the time of ordering.
the quality and suitability of the hot water being delivered. The low temperatures delivered by the heat pump also With a Torrent GreenHeat there are no health issues
mean that the radiators need to be sized to take account
because the hot water is heated indirectly and the lack of
of this or an underfloor heating system that operates at
a heat exchanger/coil for the heat pump means that the
the temperatures that can be achieved by the Heat Pump
full output is delivered directly to the thermal store. Both
should be used.
Open Vent Store Overheat
Plate Heat Exchanger Flow Domestic Hot Water Store Sensor
Hot Supply
Solid Fuel Flow (Optional)
Heat Pump Cylinder Sensor Control Thermostat
Cold Mains Domestic Hot Water Immersion Heater Heat Pump Flow Sensor
Heat Pump Flow Central Heating Flow
Cold Feed Central Heating Immersion Heater
Central Heating Return
Plate Heat Exchanger Return
Heat Pump Return Sensor Heat Pump Return
Solid Fuel Return (Optional)
12
Torrent GreenHeat HP showing how the cylinder can utilise numerous heat sources (including optional extras) at the same time
Mains pressure hot water
Cold mains water
Multi-fuel stove Central heating Heat pump
Torrent GreenHeat HP Technical Specification Description
TGH170-HP
TGH210-HP
TGH250-HP
TGH350-HP
TGH450-HP
Unit height
mm
1449
1414
1654
1874
1764
Unit diameter
mm
530
580
580
630
730
Domestic hot water volume
litres
170
210
250
350
450
litres/ minute
15
15
15
15
15
Bath
1
1
2
2
3
Shower room
1
2
1
2
2
Bed
2-3
2-3
3-4
3-4
4-5
Max. hot water flow rate
Maximum dwelling type
Notes: • Please note the diagrams shown include optional extra components. • The suggested model sizes in the selection chart are based on a store temperature of 75°C. If the intention is that the heat pump will be used to provide the majority of the hot water with minimum boost from another heat source then consideration should be given to choosing a larger model of Torrent GreenHeat HP appliance. See the Design Installation and Servicing Instructions for equivalent volumes at different charge temperatures. • If the immersion heater is to be used as the hot water boost a suitable control system should be installed to ensure that the heat pump has fully charged the appliance before the boost immersion heater is allowed to operate. This will ensure the most efficient and cost effective use of the system. • Additional height for F&E tank will need to be allowed if it is to be sited in the same cupboard. • The F&E tank must be sized to take the water expansion of the whole system (ie. solid fuel boiler, cylinder, open flue boiler and auxiliary heating).
13
Torrent GreenHeat HP SOL
Thermal store for utilising both heat pump and solar technology to provide heating and mains pressure hot water Combining all the benefits of the Torrent GreenHeat HP, Low temperature renewable heat energy recovered by the heat pump
the Torrent GreenHeat HP SOL allows the combination of heat pump, solar energy and wood burning stove in the same system, making what must be the ultimate alternative energy cylinder. The standard configuration comes fitted with a wide range of tappings, but if not required, any of these can be removed, or
Electrical power in
optional extras added at the time of ordering.
Torrent HP Solar
Hot water and heat output
Alternative energy source such as wood burning stove or solar panels
Open Vent Store Overheat
Plate Heat Exchanger Flow Domestic Hot Water Store Sensor
Solar Sensor Solid Fuel Flow (Optional)
Heat Pump Cylinder Sensor Control Thermostat
Hot Supply Domestic Hot Water Immersion Heater Heat Pump Flow Sensor
Heat Pump Flow Central Heating Flow Central Heating Return
Central Heating Immersion Heater
Heat Pump Return Sensor
Solid Fuel Return (Optional) Cold Mains
Heat Pump Return Solar Coil Flow
Solar Sensor Cold Feed Solar Coil Return
Plate Heat Exchanger Return Solid Fuel Return (Optional)
14
Torrent GreenHeat HP SOL showing how the cylinder can utilise numerous heat sources (including optional extras) at the same time
Sensor circuit Solar controller
Solar pumping station
Expansion vessel
Pressure relief
Mains pressure hot water
Multi-fuel stove Central heating
Cold mains water
Heat pump
Torrent GreenHeat HP SOL Technical Specification Description
TGH210-HPSOL
TGH250-HPSOL
TGH350-HPSOL
TGH450-HPSOL
Unit height
mm
1414
1654
1874
1764
Unit diameter
mm
580
580
630
730
Domestic hot water volume
litres
210
250
350
450
Dedicated solar volume 2
litres
60
71
100
128
Max. solar collector area 1
m2
2.40
2.84
4.00
5.12
Solar heat exch. surface area 1
m2
0.27
0.34
0.40
0.54
litres/ minute
15
15
15
15
Bath
1
1
2
2
Shower room
1
2
1
2
Bed
2-3
2-3
3-4
3-4
Max. hot water flow rate
Maximum dwelling type
Notes: 1 To comply with the Building Regulations ADL1 Domestic Heating Compliance Guide 2 This can be adjusted at the time of specification. • Please note the diagrams shown include optional extra components. • The suggested model sizes in the selection chart are based on a store temperature of 75°C. If the intention is that the heat pump will be used to provide the majority of the hot water with minimum boost from another heat source then consideration should be given to choosing a larger model of Torrent GreenHeat HP SOL appliance. See table 1b in the Design Installation and Servicing Instructions for equivalent volumes at different charge temperatures. • If the immersion heater is to be used as the hot water boost a suitable control system should be installed to ensure that the heat pump has fully charged the appliance before the boost immersion heater is allowed to operate. This will ensure the most efficient and cost effective use of the system. • Additional height for F&E tank will need to be allowed if it is to be sited in the same cupboard. • The F&E tank must be sized to take the water expansion of the whole system (ie. solid fuel boiler, cylinder, open flue boiler and auxiliary heating).
15
UK Super Depot Infrastructure Blackpool Head Office and Stainless Steel Manufacturing Site
Liverpool Telephone: 0151 227 1574 Fax: 0151 236 0898
Blackburn Telephone: 01254 693844 Fax: 01254 673615
Maidstone Telephone: 01622 714770 Fax: 01622 882286
Bristol Telephone: 01179 820814 Fax: 01179 820821
Nottingham Telephone: 01773 580684 Fax: 01773 581129
Dudley Telephone: 01384 636245 Fax: 01384 413700
Paignton Telephone: 01803 557470 Fax: 01803 559213
Hemel Hempstead Telephone: 01442 862233 Fax: 01442 862234
Reading Telephone: 01189 669990 Fax: 01189 669696
Huntingdon Telephone: 01480 415980 Fax: 01480 413331
Southampton Telephone: 01329 846601 Fax: 01329 845881
Inverkeithing Telephone: 01383 414133 Fax: 01383 413123
For technical advice call 01253 474584
SUPPLIERS TO THE MERCHANT TRADE FOR OVER 35 YEARS
Gledhill Building Products Limited Sycamore Estate, Squires Gate, Blackpool FY4 3RL Tel: 01253 474550 Fax: 01253 474551
[email protected] Gledhill Building Products produce cylinders for use with a wide range of heat sources including;
Gas and oil boilers Ground source heat pumps
Electricity Solar energy
Air source heat pumps Wood burning stoves
For further information of Gledhill products can be found on the internet at www.gledhill.net
“Only the best is acceptable”
FM 2057 Gledhill cylinders are produced under an ISO 9001:2008 Quality System accepted by BSI
Due to a programme of continuous improvement Gledhill Building Products reserve the right to modify products without prior notice. It is advisable to check the product technical detail by using the latest design and installation manuals available from our technical support team or on our website. It is an offence to copy or adapt this document without consent of the owner. Spec 134/01 04/13