Preview only show first 10 pages with watermark. For full document please download

Goodman 14seer Hp Specs

   EMBED


Share

Transcript

SSZ14 HIGH-EFFICIENCY, R-410A SPLIT SYSTEM HEAT PUMP P RODUCT S PECIFICATIONS The Goodman® SSZ14 uses the environmentally friendly refrigerant R-410A and features operating sound levels that are among the best in the heating and cooling industry. R-410A is chlorine-free to help prevent damage to the ozone layer. With its 14 SEER rating, the SSZ14 will help reduce energy consumption throughout the life of the system. Standard Features • • • • • • • • • • 14 SEER • • • 1½ TO 5 TON R-410A environmentally friendly refrigerant High-efficiency scroll compressor High-quality compressor sound blanket High- and low-pressure switches 850 RPM condenser fan motor Liquid refrigerant return protection Factory-installed, bi-flow liquid line filter dryer Service valves with sweat connections and easy-access gauge ports Copper tube/enhanced aluminum fin coil Reliable time-initiated, temperature-terminated defrost control Contactor with lug connection Ground lug connection ARI Certified; ETL Certified Cabinet Features COOLING CAPACITY: 18,000 TO 57,600 BTU/H HEATING CAPACITY: 18,000 TO 59,000 BTU/H • • • • Unique Goodman® sound control top design Steel louver coil guard Heavy-gauge galvanized-steel cabinet Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval • Top and side maintenance access • Service ports and controls are accessible while unit is operating • When properly anchored, meets the 2001 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.) Contents Nomenclature.......................................................... 2 Accessories ............................................................... 2 Product Specifications.......................................... 3 Expanded Cooling Data ....................................... 4 Expanded Heating Data.....................................18 ARI Performance Ratings ...................................20 Dimensions.............................................................35 Wiring Diagram .....................................................36 SS-SSZ14 www.goodmanmfg.com 7/08 Supersedes 6/08 PRODUCT SPECIFICATIONS NOMENCLATURE S S Z 14 036 1 A A 1 2 3 4,5 6,7,8 9 10 11 Brand G Goodman® (Standard Feature Set Models) S Goodman® (High Feature Set Models) Engineering * Minor Revision Engineering * Major Revision Product Category S Split System 1 2 3 4 5 Unit Type C Condenser R-22 X Condenser R-410A H Heat Pump R-22 Z Heat Pump R-410A Efficiency 13 13 SEER 14 14 SEER 16 16 SEER 018 024 030 036 042 Electrical 208/230 V, 1 Phase, 60 Hz 220/240 V, 1 Phase, 50 Hz 208/230 V, 3 Phase, 60 Hz 460 V, 3 Phase, 60 Hz 380/415 V, 3 Phase, 50 Hz 1½ Tons 2 Tons 2½ Tons 3 Tons 3½ Tons Nominal Capacity 048 4 Tons 060 5 Tons 090 7½ tons 120 10 Tons * Neither used for order entry or inventory management. ACCESSORIES Model SSZ14 SSZ14 SSZ14 SSZ14 SSZ14 SSZ14 SSZ14 018 024 030 036 042 048 060 Description ABK-20 Anchor Bracket Kit * X X X X X X X AFE18-60A ASC-01 CSR-U-1 CSR-U-2 CSR-U-3 FSK01A¹ OT/EHR18-60 OT18-60A² TX2N4³ All-fuel Kit Anti-Short Cycle Kit Hard-start Kit Hard-start Kit Hard-start Kit Freeze Protection Kit Emergency Heat Relay kit Outdoor Thermostat w/ Lockout Stat TXV Kit X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X TX3N4³ TX5N4³ TXV Kit TXV Kit X X X X X X X * ¹ ² ³ 2 Contains 20 brackets; four brackets needed to anchor unit to pad Installed on indoor coil Required for heat pump applications where ambient temperatures fall below 0 °F with 50% or higher relative humidity. Condensing units and heat pumps with reciprocating compressors require the use of start-assist components when used in conjunction with an indoor coil using a non-bleed thermal expansion valve refrigerant metering device www.goodmanmfg.com SS-SSZ14 PRODUCT SPECIFICATIONS SPECIFICATIONS Nominal Capacities Cooling (BTU/h) Heating (BTU/h) Decibels Compressor RLA LRA Condenser Fan Motor Horsepower FLA Refrigeration System Refrigerant Line Size¹ Liquid Line Size (“O.D.) Suction Line Size (“O.D.) Refrigerant Connection Size Liquid Valve Size (“O.D.) Suction Valve Size (“O.D.) Valve Connection Type Refrigerant Charge Electrical Data Volts / Hz / Phase Minimum Circuit Ampacity ² Max. Overcurrent Protection ³ Min / Max Volts Electrical Conduit Size Ship Weight (lbs) SSZ14 0181A SSZ14 0241A SSZ14 0301A SSZ14 0361A SSZ14 0421A SSZ14 0481A SSZ14 0601A 18,000 18,000 70 24,000 24,000 72 28,800 29,000 72 35,000 35,000 73 40,000 41,000 73 46,000 47,000 74 57,000 58,000 75 9.0 48.0 12.8 58.3 14.1 73.0 16.6 79.0 17.9 112.0 19.8 109.0 26.4 134.0 1 1 1 /12 0.6 /6 1.50 /6 1.10 ¼ ¼ ¼ ¼ 1.60 1.60 1.60 1.60 ⅜” ¾” ⅜” ¾” ⅜” ¾” ⅜” ⅞” ⅜” 1⅛” ⅜” 1⅛” ⅜” 1⅛” ⅜” ¾” ⅜” ¾” ⅜” ¾” ⅜” ⅞” ⅜” ⅞” ⅜” ⅞” ⅜” ⅞” Sweat 150 Sweat 170 Sweat 195 Sweat 220 Sweat 220 Sweat 280 Sweat 285 11.8 20 197 / 253 208/230-60-1 17.5 18.7 30 30 197 / 253 197 / 253 22.4 30 197 / 253 208/230-60-1 24.0 26.4 34.6 40 40 60 197 / 253 197 / 253 197 / 253 ½” or ¾” ½” or ¾” ½” or ¾” ½” or ¾” ½” or ¾” ½” or ¾” ½” or ¾” 199 207 219 242 242 266 280 ¹ Tested and rated in accordance with ARI Standard 210/240 ² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes ³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted. Notes • Always check the S&R plate for electrical data on the unit being installed. • Installer will need to supply ⅞” to 1⅛” adapters for suction line connections. • Unit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure. • Installation of these units requires the speci ed TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT NOT THE INDOOR COIL. Important EnergyStar Notice: Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet EnergyStar criteria. Ask your contractor for details or visit www.energystar.gov. SS-SSZ14 www.goodmanmfg.com 3 4 www.goodmanmfg.com 17.9 0.84 20 1.18 4.2 215 108 17.4 0.80 21 1.17 4.2 213 107 16.1 0.77 22 1.14 4.1 206 103 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR 525 600 675 59 17.6 0.74 18 1.17 4.2 213 107 17.1 0.70 18 1.16 4.2 210 105 15.8 0.68 19 1.13 4.1 204 102 Airflow MBh S/T ∆T 675 kW Amps Hi PR Lo PR MBh S/T ∆T 600 kW Amps Hi PR Lo PR MBh S/T ∆T 525 kW Amps Hi PR Lo PR 18.5 0.75 19 1.20 4.3 231 114 17.9 0.71 20 1.19 4.3 229 113 16.5 0.69 20 1.16 4.2 222 110 63 18.3 0.62 15 1.19 4.3 229 113 17.7 0.59 16 1.18 4.3 227 112 16.4 0.57 16 1.15 4.2 220 109 20.0 0.57 15 1.24 4.5 244 125 19.4 0.54 16 1.23 4.4 242 124 17.9 0.52 16 1.20 4.3 234 120 67 20.0 0.43 12 1.23 4.4 242 124 19.4 0.41 12 1.22 4.4 239 122 17.9 0.39 12 1.19 4.3 232 119 Shaded area is ACCA (TVA) conditions 75 70 IDB* 65ºF 21.5 0.36 11 1.27 4.6 255 133 20.8 0.35 11 1.26 4.6 252 132 19.2 0.34 11 1.24 4.5 244 128 71 18.0 0.78 19 1.29 4.7 259 121 17.5 0.74 20 1.28 4.6 257 120 16.2 0.71 20 1.25 4.5 249 116 63 17.9 0.64 16 1.28 4.6 257 120 17.3 0.61 16 1.27 4.6 254 119 16.0 0.59 16 1.24 4.5 247 115 19.5 0.59 16 1.33 4.8 274 132 19.0 0.56 16 1.32 4.8 271 131 17.5 0.54 17 1.29 4.7 263 127 67 19.6 0.44 12 1.32 4.8 271 131 19.0 0.42 12 1.31 4.8 268 129 17.5 0.41 12 1.28 4.6 260 126 21.0 0.38 11 1.37 5.0 286 141 20.3 0.36 11 1.36 5.0 283 139 18.8 0.35 11 1.33 4.8 274 135 71 17.1 0.89 21 1.34 5.0 274 118 16.6 0.85 22 1.33 4.9 271 117 15.3 0.82 22 1.30 4.8 263 113 17.6 0.80 19 1.37 5.1 295 126 17.1 0.76 20 1.36 5.0 292 124 15.8 0.73 20 1.32 4.9 283 121 19.1 0.60 16 1.41 5.2 311 137 18.5 0.57 16 1.40 5.2 308 136 17.1 0.55 17 1.37 5.1 299 132 20.5 0.39 11 1.46 5.4 325 146 19.9 0.37 11 1.44 5.4 322 145 18.3 0.36 11 1.41 5.2 312 140 17.2 0.82 19 1.44 5.4 336 132 16.7 0.78 20 1.43 5.4 333 131 15.4 0.76 20 1.39 5.2 323 127 18.6 0.62 16 1.48 5.6 355 144 18.1 0.59 16 1.47 5.6 351 143 16.7 0.57 17 1.44 5.4 341 138 20.0 0.40 11 1.53 5.8 370 154 19.4 0.38 11 1.52 5.8 366 152 17.9 0.37 12 1.48 5.6 355 147 71 15.9 0.95 21 1.46 5.6 351 130 15.4 0.91 21 1.45 5.6 348 129 14.2 0.88 22 1.42 5.4 337 125 59 15.6 0.84 18 1.45 5.6 348 129 15.1 0.80 19 1.44 5.5 344 127 14.0 0.77 19 1.41 5.4 334 124 16.3 0.85 19 1.50 5.8 378 138 15.8 0.81 20 1.48 5.7 374 137 14.6 0.78 20 1.45 5.6 363 133 63 16.2 0.70 15 1.48 5.7 374 137 15.7 0.67 16 1.47 5.7 370 136 14.5 0.64 16 1.44 5.5 359 132 17.7 0.65 16 1.54 6.0 399 151 17.2 0.62 16 1.53 5.9 395 150 15.8 0.59 16 1.49 5.7 383 145 67 17.7 0.49 12 1.53 5.9 395 150 17.2 0.46 12 1.52 5.9 391 148 15.9 0.45 12 1.48 5.7 379 144 105ºF 19.0 0.42 11 1.59 6.2 416 161 18.4 0.40 11 1.58 6.1 412 159 17.0 0.38 11 1.54 6.0 400 155 71 14.7 0.96 19 1.51 6.0 388 135 14.3 0.92 20 1.50 5.9 384 133 13.2 0.88 20 1.47 5.7 373 129 59 14.4 0.85 17 1.50 5.9 384 133 14.0 0.81 17 1.49 5.9 380 132 12.9 0.78 18 1.45 5.7 369 128 15.1 0.86 18 1.55 6.1 418 143 14.7 0.82 18 1.53 6.1 413 142 13.5 0.79 19 1.50 5.9 401 137 63 15.0 0.71 14 1.53 6.1 413 142 14.5 0.67 15 1.52 6.0 409 140 13.4 0.65 15 1.48 5.8 397 136 16.4 0.65 15 1.60 6.3 441 156 15.9 0.62 15 1.58 6.3 437 155 14.7 0.60 15 1.54 6.1 423 150 67 16.4 0.49 11 1.58 6.3 436 155 15.9 0.47 11 1.57 6.2 432 153 14.7 0.45 12 1.53 6.0 419 149 115ºF 17.6 0.42 10 1.65 6.5 460 166 17.1 0.40 10 1.64 6.5 455 165 15.7 0.39 11 1.60 6.3 442 160 71 - kW=Total system power Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions 16.7 0.92 21 1.41 5.3 312 124 16.2 0.88 22 1.40 5.3 309 123 15.0 0.84 22 1.36 5.1 300 119 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 16.8 17.4 19.1 16.4 17.0 18.6 0.78 0.65 0.45 0.81 0.67 0.47 18 16 12 18 16 12 1.33 1.36 1.40 1.40 1.43 1.47 4.9 5.0 5.2 5.3 5.4 5.6 271 292 308 309 333 351 117 124 136 123 131 143 16.3 16.9 18.5 15.9 16.5 18.1 0.75 0.62 0.43 0.77 0.64 0.45 19 16 12 19 16 12 1.32 1.35 1.39 1.38 1.41 1.46 4.9 5.0 5.2 5.2 5.3 5.5 269 289 305 306 329 348 116 123 134 122 129 141 15.1 15.6 17.1 14.7 15.2 16.7 0.72 0.60 0.42 0.74 0.62 0.43 19 16 12 19 17 13 1.29 1.31 1.35 1.35 1.38 1.42 4.7 4.9 5.0 5.1 5.2 5.4 261 280 296 297 319 337 112 119 130 118 126 137 IDB: Entering Indoor Dry Bulb Temperature 17.5 0.87 21 1.26 4.6 241 114 17.0 0.83 22 1.25 4.5 239 113 15.7 0.80 22 1.22 4.4 231 109 59 17.2 0.76 18 1.25 4.5 239 113 16.7 0.73 19 1.24 4.5 236 111 15.4 0.70 19 1.21 4.4 229 108 75ºF PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — SSZ140181A* / CA*F3131*6A* +TXV / MBR800**-1 SS-SSZ14 SS-SSZ14 www.goodmanmfg.com 18.6 0.96 24 1.19 4.3 219 110 18.0 0.92 25 1.19 4.3 217 109 16.6 0.89 26 1.16 4.2 210 105 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR 525 600 675 59 18.3 0.92 23 1.19 4.3 217 109 17.7 0.88 24 1.18 4.2 215 108 16.4 0.84 24 1.15 4.1 208 104 Airflow MBh S/T ∆T 675 kW Amps Hi PR Lo PR MBh S/T ∆T 600 kW Amps Hi PR Lo PR MBh S/T ∆T 525 kW Amps Hi PR Lo PR 18.9 0.93 24 1.22 4.4 236 117 18.4 0.89 25 1.21 4.4 233 116 17.0 0.85 25 1.18 4.3 226 112 63 18.7 0.86 22 1.21 4.4 233 116 18.1 0.82 23 1.20 4.3 231 114 16.7 0.79 23 1.17 4.2 224 111 19.8 0.84 23 1.26 4.6 249 127 19.3 0.80 24 1.25 4.5 247 126 17.8 0.77 24 1.22 4.4 239 122 67 19.9 0.70 19 1.25 4.5 247 126 19.4 0.67 20 1.24 4.5 244 125 17.9 0.64 20 1.21 4.4 237 121 Shaded area is ARI Rating Conditions 85 80 IDB* 65ºF 21.2 0.68 20 1.29 4.7 260 136 20.5 0.65 20 1.28 4.7 257 134 19.0 0.63 21 1.25 4.6 249 130 71 21.3 0.52 15 1.28 4.7 257 134 20.7 0.50 16 1.27 4.6 255 133 19.1 0.48 16 1.24 4.5 247 129 18.5 0.96 24 1.31 4.8 265 123 18.0 0.92 25 1.30 4.7 262 122 16.6 0.89 26 1.27 4.6 254 118 63 18.2 0.89 22 1.30 4.7 262 122 17.7 0.85 23 1.29 4.7 259 121 16.3 0.82 23 1.26 4.6 252 117 19.4 0.87 23 1.35 4.9 279 135 18.8 0.83 24 1.34 4.9 277 133 17.4 0.80 24 1.31 4.8 268 129 67 19.5 0.73 19 1.34 4.9 277 133 18.9 0.69 20 1.33 4.8 274 132 17.4 0.67 20 1.30 4.7 266 128 20.7 0.71 20 1.39 5.1 291 143 20.1 0.67 21 1.38 5.1 288 142 18.5 0.65 21 1.35 4.9 280 138 71 20.8 0.54 15 1.38 5.1 288 142 20.2 0.52 16 1.37 5.0 286 141 18.6 0.50 16 1.34 4.9 277 136 17.7 1.00 24 1.36 5.1 280 121 17.2 0.98 26 1.35 5.0 277 119 15.9 0.94 26 1.32 4.9 269 116 18.1 0.99 24 1.39 5.2 301 128 17.5 0.94 25 1.38 5.1 298 127 16.2 0.91 26 1.35 5.0 289 123 18.9 0.89 23 1.43 5.3 318 140 18.4 0.85 24 1.42 5.3 315 139 16.9 0.82 24 1.39 5.2 305 134 20.2 0.72 20 1.48 5.5 331 149 19.6 0.69 21 1.47 5.5 328 148 18.1 0.66 21 1.43 5.3 318 143 17.6 1.00 24 1.46 5.5 343 135 17.1 0.97 25 1.45 5.5 339 133 15.8 0.94 26 1.41 5.3 329 129 18.4 0.92 23 1.51 5.7 362 147 17.9 0.88 24 1.50 5.7 358 146 16.5 0.85 24 1.46 5.5 348 141 19.7 0.75 20 1.56 5.9 377 157 19.1 0.71 21 1.54 5.9 374 155 17.6 0.69 21 1.51 5.7 362 150 5 16.4 1.00 22 1.49 5.7 358 133 15.9 1.00 24 1.48 5.7 355 131 14.7 1.00 26 1.44 5.5 344 127 59 16.1 1.00 22 1.48 5.7 355 131 15.7 1.00 24 1.46 5.6 351 130 14.5 0.96 24 1.43 5.5 341 126 16.7 1.00 23 1.52 5.9 386 141 16.2 1.00 25 1.51 5.8 382 140 15.0 0.97 26 1.47 5.7 370 136 63 16.5 1.00 22 1.51 5.8 382 140 16.0 0.94 23 1.50 5.8 378 138 14.8 0.90 23 1.46 5.6 367 134 18.7 0.77 20 1.62 6.3 425 164 18.2 0.74 21 1.61 6.2 420 162 16.8 0.71 21 1.57 6.1 408 158 71 18.8 0.60 15 1.61 6.2 420 162 18.3 0.57 16 1.59 6.2 416 161 16.9 0.55 16 1.56 6.0 404 156 15.2 1.00 21 1.54 6.1 396 137 14.8 1.00 23 1.53 6.0 392 136 13.6 1.00 24 1.49 5.9 380 132 59 14.9 1.00 20 1.53 6.0 392 136 14.5 1.00 22 1.51 6.0 388 135 13.4 0.97 23 1.48 5.8 376 131 15.5 1.00 21 1.57 6.2 426 146 15.0 1.00 23 1.56 6.2 422 145 13.9 0.98 24 1.52 6.0 409 140 63 15.3 1.00 21 1.56 6.2 422 145 14.8 0.94 21 1.55 6.1 418 143 13.7 0.91 22 1.51 5.9 405 139 16.2 0.96 21 1.62 6.4 450 159 15.8 0.92 22 1.61 6.4 445 158 14.5 0.89 23 1.57 6.2 432 153 67 16.3 0.80 18 1.61 6.4 445 158 15.8 0.77 19 1.60 6.3 441 156 14.6 0.74 19 1.56 6.1 428 152 115ºF 17.3 0.78 18 1.68 6.7 469 170 16.8 0.74 19 1.66 6.6 465 168 15.5 0.72 20 1.62 6.4 451 163 71 17.4 0.60 14 1.66 6.6 465 168 16.9 0.57 15 1.65 6.5 460 166 15.6 0.55 15 1.61 6.4 446 161 Amps = outdoor unit amps (comp.+fan) 17.5 0.95 23 1.57 6.1 407 154 17.0 0.91 24 1.56 6.0 403 153 15.7 0.88 24 1.52 5.8 391 148 67 17.6 0.80 19 1.56 6.0 403 153 17.1 0.76 20 1.54 6.0 399 151 15.8 0.73 20 1.51 5.8 387 147 105ºF Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions kW=Total system power 17.3 1.00 24 1.43 5.4 318 127 16.8 1.00 26 1.42 5.3 315 125 15.5 0.97 26 1.38 5.2 306 122 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 71 17.4 17.8 19.0 20.3 17.0 17.4 18.5 19.8 1.00 0.92 0.75 0.56 1.00 0.94 0.77 0.57 24 22 19 15 23 22 19 16 1.35 1.38 1.42 1.47 1.42 1.45 1.50 1.54 5.0 5.1 5.3 5.5 5.3 5.5 5.7 5.9 277 298 315 328 315 339 358 374 119 127 139 148 125 133 146 155 16.9 17.3 18.5 19.7 16.5 16.8 18.0 19.2 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 24 23 20 16 24 23 20 16 1.34 1.37 1.41 1.46 1.41 1.44 1.48 1.53 5.0 5.1 5.3 5.4 5.3 5.4 5.6 5.8 274 295 311 325 312 336 355 370 118 126 137 146 124 132 144 154 15.6 15.9 17.0 18.2 15.2 15.6 16.6 17.8 0.90 0.84 0.69 0.51 0.93 0.87 0.71 0.53 25 23 20 16 25 24 21 16 1.31 1.34 1.38 1.42 1.37 1.40 1.45 1.49 4.8 4.9 5.1 5.3 5.2 5.3 5.5 5.7 266 286 302 315 303 326 344 359 115 122 133 142 120 128 140 149 IDB: Entering Indoor Dry Bulb Temperature 18.1 1.00 25 1.28 4.7 246 116 17.6 0.95 26 1.27 4.6 243 115 16.3 0.92 26 1.24 4.5 236 111 59 17.8 0.95 23 1.27 4.6 243 115 17.3 0.91 24 1.26 4.6 241 114 16.0 0.88 24 1.23 4.5 234 110 75ºF PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — SSZ140181A* / CA*F3131*6A* +TXV / MBR800**-1 (CONT.) 6 www.goodmanmfg.com 23.9 0.86 20 1.66 10.1 224 111 23.2 0.82 21 1.65 10.1 222 110 21.4 0.79 21 1.61 9.9 215 107 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR 744 850 956 59 23.5 0.75 17 1.65 10.1 222 110 22.8 0.72 18 1.64 10.0 220 109 21.1 0.69 18 1.60 9.8 213 106 Airflow MBh S/T ∆T 956 kW Amps Hi PR Lo PR MBh S/T ∆T 850 kW Amps Hi PR Lo PR MBh S/T ∆T 744 kW Amps Hi PR Lo PR 24.6 0.77 18 1.70 10.2 241 118 23.9 0.73 19 1.68 10.2 239 117 22.1 0.70 19 1.64 10.0 232 114 63 24.4 0.63 15 1.68 10.2 239 117 23.7 0.60 15 1.67 10.1 236 116 21.8 0.58 16 1.63 10.0 229 112 26.7 0.58 15 1.75 10.4 255 129 25.9 0.55 15 1.73 10.4 252 128 23.9 0.53 16 1.69 10.2 245 124 67 26.7 0.44 11 1.73 10.4 252 128 25.9 0.42 12 1.72 10.3 250 127 23.9 0.40 12 1.68 10.2 242 123 Shaded area is ACCA (TVA) conditions 75 70 IDB* 65ºF 28.6 0.37 10 1.80 10.7 266 138 27.8 0.36 11 1.78 10.6 263 136 25.6 0.34 11 1.74 10.4 255 132 71 24.1 0.79 18 1.82 10.7 271 125 23.4 0.76 19 1.80 10.7 268 124 21.6 0.73 19 1.76 10.5 260 120 63 23.8 0.65 15 1.80 10.7 268 124 23.1 0.62 16 1.79 10.6 265 122 21.3 0.60 16 1.75 10.4 257 119 26.0 0.60 15 1.87 10.9 286 136 25.3 0.57 16 1.86 10.9 283 135 23.3 0.55 16 1.82 10.7 275 131 67 26.1 0.45 11 1.86 10.9 283 135 25.3 0.43 12 1.84 10.8 280 134 23.4 0.42 12 1.80 10.6 272 130 27.9 0.39 10 1.93 11.2 298 145 27.1 0.37 11 1.92 11.1 295 144 25.0 0.36 11 1.87 10.9 286 140 71 22.8 0.91 20 1.89 11.1 286 122 22.1 0.87 21 1.87 11.0 283 121 20.4 0.84 21 1.83 10.9 275 117 23.5 0.81 18 1.93 11.3 308 130 22.8 0.78 19 1.91 11.2 305 129 21.0 0.75 19 1.87 11.0 296 125 25.4 0.62 15 1.99 11.5 325 142 24.7 0.59 16 1.97 11.4 322 140 22.8 0.57 16 1.92 11.2 312 136 27.3 0.40 10 2.05 11.8 339 151 26.5 0.38 11 2.03 11.7 336 150 24.4 0.36 11 1.98 11.5 326 145 22.9 0.84 19 2.02 11.8 351 136 22.2 0.80 19 2.01 11.7 347 135 20.5 0.77 20 1.96 11.5 337 131 24.8 0.64 15 2.09 12.0 370 149 24.1 0.61 16 2.07 11.9 367 147 22.2 0.58 16 2.02 11.7 356 143 26.6 0.41 10 2.15 12.3 386 159 25.8 0.39 11 2.13 12.2 382 157 23.8 0.38 11 2.08 12.0 371 152 71 - SS-SSZ14 21.1 0.98 20 2.06 12.0 367 134 20.5 0.93 21 2.04 12.0 363 133 18.9 0.90 21 2.00 11.8 352 129 59 20.8 0.86 17 2.04 12.0 363 133 20.2 0.82 18 2.03 11.9 359 132 18.6 0.79 18 1.98 11.7 349 128 21.8 0.87 18 2.10 12.2 395 143 21.1 0.83 19 2.09 12.2 391 142 19.5 0.80 19 2.04 11.9 379 137 63 21.5 0.72 15 2.09 12.2 391 142 20.9 0.68 15 2.07 12.1 387 140 19.3 0.66 16 2.02 11.9 375 136 25.3 0.42 10 2.24 12.8 435 166 24.5 0.41 11 2.22 12.7 430 165 22.7 0.39 11 2.17 12.5 417 160 71 19.6 0.98 19 2.13 12.5 405 139 19.0 0.94 19 2.11 12.4 401 138 17.5 0.90 20 2.06 12.2 389 133 59 19.3 0.87 16 2.11 12.4 401 138 18.7 0.83 17 2.09 12.3 397 136 17.3 0.80 17 2.04 12.1 385 132 20.2 0.88 17 2.17 12.7 436 148 19.6 0.84 18 2.16 12.6 432 146 18.1 0.81 18 2.10 12.4 419 142 63 20.0 0.72 14 2.16 12.6 432 146 19.4 0.69 14 2.14 12.5 427 145 17.9 0.66 15 2.09 12.3 414 141 21.8 0.67 14 2.24 13.0 460 161 21.2 0.63 15 2.22 12.9 456 160 19.6 0.61 15 2.17 12.7 442 155 67 21.9 0.50 11 2.22 12.9 456 160 21.2 0.48 11 2.21 12.8 451 158 19.6 0.46 11 2.15 12.6 438 153 115ºF 23.4 0.43 10 2.32 13.3 480 172 22.7 0.41 10 2.30 13.2 475 170 21.0 0.39 10 2.24 13.0 461 165 71 - Amps = outdoor unit amps (comp.+fan) 23.6 0.66 15 2.17 12.5 417 156 22.9 0.63 16 2.15 12.4 412 155 21.1 0.61 16 2.10 12.2 400 150 67 23.6 0.50 11 2.15 12.4 412 155 22.9 0.47 12 2.14 12.3 408 153 21.1 0.46 12 2.08 12.1 396 148 105ºF Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions kW=Total system power 22.2 0.94 20 1.98 11.6 326 128 21.6 0.90 21 1.97 11.5 323 127 19.9 0.86 21 1.92 11.3 313 123 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 22.4 23.2 25.5 21.9 22.7 24.8 0.80 0.67 0.46 0.83 0.69 0.48 17 15 11 17 15 11 1.87 1.91 1.97 1.97 2.01 2.07 11.0 11.2 11.4 11.5 11.7 11.9 283 305 322 323 347 367 121 129 140 127 135 147 21.8 22.6 24.7 21.2 22.0 24.1 0.76 0.64 0.44 0.79 0.66 0.46 18 16 12 18 16 12 1.86 1.90 1.95 1.95 1.99 2.05 11.0 11.1 11.4 11.4 11.6 11.9 280 302 319 319 344 363 120 127 139 126 134 146 20.1 20.8 22.8 19.6 20.3 22.3 0.74 0.62 0.43 0.76 0.63 0.44 18 16 12 18 16 12 1.82 1.85 1.91 1.90 1.94 2.00 10.8 11.0 11.2 11.2 11.4 11.7 272 293 309 310 333 352 116 123 135 122 130 142 IDB: Entering Indoor Dry Bulb Temperature 23.4 0.89 20 1.78 10.6 252 117 22.7 0.85 21 1.77 10.5 249 116 20.9 0.82 21 1.73 10.3 242 113 59 23.0 0.78 17 1.77 10.5 249 116 22.3 0.74 18 1.75 10.5 247 115 20.6 0.72 18 1.72 10.3 239 112 75ºF PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — SSZ140241A* / CA*F3636*6A*+TXV / MBR800**-1 SS-SSZ14 www.goodmanmfg.com 24.8 0.98 23 1.69 10.2 229 113 24.0 0.94 24 1.67 10.2 226 112 22.2 0.91 ∆T 1.64 10.0 220 109 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR 744 850 956 59 24.3 0.94 22 1.67 10.2 226 112 23.6 0.90 23 1.66 10.1 224 111 21.8 0.86 23 1.63 9.9 217 108 Airflow MBh S/T ∆T 956 kW Amps Hi PR Lo PR MBh S/T ∆T 850 kW Amps Hi PR Lo PR MBh S/T ∆T 744 kW Amps Hi PR Lo PR 25.2 0.95 23 1.72 10.3 246 121 24.5 0.91 24 1.71 10.3 244 119 22.6 0.87 24 1.67 10.1 236 116 63 24.9 0.88 21 1.71 10.3 244 119 24.1 0.84 22 1.70 10.2 241 118 22.3 0.81 22 1.66 10.1 234 115 26.4 0.86 22 1.77 10.5 260 132 25.7 0.82 23 1.76 10.5 257 130 23.7 0.79 23 1.72 10.3 250 127 67 26.6 0.72 18 1.76 10.5 257 130 25.8 0.68 19 1.75 10.4 255 129 23.8 0.66 19 1.71 10.3 247 125 Shaded area is ARI Rating Conditions 85 80 IDB* 65ºF 28.2 0.70 19 1.83 10.8 271 140 27.4 0.66 20 1.81 10.7 268 139 25.3 0.64 20 1.77 10.5 260 135 71 28.4 0.54 15 1.81 10.7 268 139 27.6 0.51 15 1.80 10.7 266 138 25.5 0.49 16 1.76 10.5 258 133 24.7 0.98 23 1.85 10.8 276 127 23.9 0.94 24 1.83 10.8 273 126 22.1 0.91 25 1.79 10.6 265 122 63 24.3 0.91 21 1.83 10.8 273 126 23.6 0.87 22 1.82 10.7 271 125 21.8 0.84 23 1.78 10.5 263 121 25.8 0.89 22 1.90 11.1 292 139 25.1 0.85 23 1.89 11.0 289 138 23.1 0.82 23 1.84 10.8 280 134 67 26.0 0.74 19 1.89 11.0 289 138 25.2 0.71 19 1.87 10.9 286 136 23.3 0.68 20 1.83 10.7 277 132 27.6 0.72 19 1.96 11.3 304 148 26.8 0.69 20 1.95 11.2 301 147 24.7 0.66 20 1.90 11.0 292 142 71 27.7 0.56 15 1.95 11.2 301 147 26.9 0.53 15 1.93 11.2 298 145 24.9 0.51 16 1.89 11.0 289 141 23.6 1.00 23 1.92 11.2 292 125 22.9 1.00 25 1.90 11.2 289 123 21.2 0.96 25 1.86 11.0 280 120 24.1 1.00 23 1.96 11.4 314 132 23.4 0.96 24 1.94 11.3 311 131 21.6 0.93 25 1.90 11.1 302 127 25.2 0.91 22 2.02 11.6 332 145 24.5 0.87 23 2.00 11.6 328 143 22.6 0.84 23 1.95 11.4 319 139 26.9 0.74 19 2.08 11.9 346 154 26.1 0.71 20 2.06 11.8 343 153 24.1 0.68 20 2.02 11.6 332 148 23.5 1.00 23 2.05 11.9 358 139 22.8 0.99 25 2.04 11.8 354 138 21.0 0.96 25 1.99 11.6 344 134 24.6 0.94 22 2.12 12.1 378 152 23.9 0.90 23 2.10 12.1 374 150 22.0 0.87 24 2.05 11.9 363 146 26.2 0.76 19 2.19 12.4 394 162 25.5 0.73 20 2.17 12.4 390 160 23.5 0.70 20 2.12 12.1 378 155 7 21.9 1.00 21 2.09 12.2 374 137 21.2 1.00 23 2.08 12.1 370 136 19.6 1.00 24 2.03 11.9 359 132 59 21.5 1.00 21 2.08 12.1 370 136 20.9 1.00 23 2.06 12.0 367 134 19.3 0.98 23 2.01 11.8 356 130 22.3 1.00 21 2.14 12.4 402 146 21.7 1.00 23 2.12 12.3 399 144 20.0 0.99 25 2.07 12.1 387 140 63 22.0 1.00 21 2.12 12.3 399 144 21.3 0.96 22 2.10 12.2 395 143 19.7 0.92 22 2.05 12.0 383 139 24.9 0.79 19 2.28 13.0 443 170 24.2 0.76 20 2.26 12.9 439 168 22.3 0.73 20 2.20 12.6 426 163 71 25.1 0.61 15 2.26 12.9 439 168 24.4 0.58 15 2.24 12.8 435 166 22.5 0.56 16 2.19 12.6 422 161 20.3 1.00 19 2.16 12.7 413 142 19.7 1.00 21 2.15 12.6 409 140 18.2 1.00 22 2.09 12.3 397 136 59 19.9 1.00 19 2.15 12.6 409 140 19.3 1.00 21 2.13 12.5 405 139 17.9 0.99 22 2.08 12.3 393 135 20.7 1.00 20 2.21 12.9 445 151 20.1 1.00 22 2.19 12.8 440 149 18.5 1.00 23 2.14 12.5 427 145 63 20.4 1.00 20 2.19 12.8 440 149 19.8 0.96 21 2.17 12.7 436 148 18.2 0.93 21 2.12 12.5 423 143 21.6 0.98 20 2.28 13.1 470 165 21.0 0.94 21 2.26 13.1 465 163 19.4 0.91 22 2.21 12.8 451 158 67 21.8 0.82 17 2.26 13.1 465 163 21.1 0.79 18 2.24 13.0 460 161 19.5 0.76 18 2.19 12.7 447 157 115ºF 23.1 0.80 18 2.35 13.5 490 175 22.4 0.76 18 2.33 13.4 485 174 20.7 0.73 19 2.28 13.1 470 168 71 23.3 0.62 14 2.33 13.4 485 174 22.6 0.59 14 2.32 13.3 480 172 20.8 0.57 15 2.26 13.1 466 167 Amps = outdoor unit amps (comp.+fan) 23.4 0.98 22 2.21 12.6 425 159 22.7 0.93 23 2.19 12.6 421 158 20.9 0.90 23 2.13 12.3 408 153 67 23.5 0.82 18 2.19 12.6 421 158 22.8 0.78 19 2.17 12.5 417 156 21.0 0.75 20 2.12 12.3 404 151 105ºF Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions kW=Total system power 23.0 1.00 22 2.01 11.7 332 131 22.4 1.00 24 2.00 11.6 329 130 20.6 0.99 25 1.95 11.4 319 126 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 71 23.2 23.7 25.3 27.1 22.6 23.1 24.7 26.4 1.00 0.94 0.76 0.57 1.00 0.97 0.79 0.59 22 21 19 15 22 21 19 15 1.90 1.94 2.00 2.06 2.00 2.04 2.10 2.17 11.2 11.3 11.6 11.8 11.6 11.8 12.1 12.4 289 311 328 343 329 354 374 390 123 131 143 153 130 138 150 160 22.5 23.0 24.6 26.3 22.0 22.5 24.0 25.7 0.95 0.89 0.73 0.54 0.98 0.92 0.75 0.56 23 22 19 15 23 22 19 16 1.89 1.93 1.99 2.05 1.98 2.02 2.09 2.15 11.1 11.3 11.5 11.8 11.6 11.8 12.0 12.3 286 308 325 339 326 351 370 386 122 130 142 151 128 136 149 159 20.8 21.3 22.7 24.3 20.3 20.7 22.2 23.7 0.92 0.86 0.70 0.52 0.95 0.89 0.72 0.54 24 23 20 16 24 23 20 16 1.84 1.88 1.94 2.00 1.93 1.97 2.04 2.10 10.9 11.1 11.3 11.6 11.4 11.5 11.8 12.1 278 299 315 329 316 340 359 375 118 126 138 146 124 132 144 154 IDB: Entering Indoor Dry Bulb Temperature 24.2 1.00 23 1.81 10.7 257 120 23.5 0.97 25 1.80 10.6 254 119 21.7 0.94 25 1.75 10.5 246 115 59 23.8 1.00 23 1.80 10.6 254 119 23.1 0.93 23 1.78 10.6 252 117 21.3 0.90 24 1.74 10.4 244 114 75ºF PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — SSZ140241A* / CA*F3636*6A*+TXV / MBR800**-1 (CONT.) 8 www.goodmanmfg.com 59 28.2 0.79 17 1.99 2.3 221 112 27.4 0.75 18 1.98 2.3 218 111 25.3 0.72 18 1.94 2.1 212 107 28.7 0.89 20 2.01 2.4 223 113 27.9 0.85 21 1.99 2.3 221 112 25.7 0.82 21 1.95 2.1 214 109 Airflow MBh S/T ∆T 1181 kW Amps Hi PR Lo PR MBh S/T ∆T 1050 kW Amps Hi PR Lo PR MBh S/T ∆T 919 kW Amps Hi PR Lo PR MBh S/T ∆T kW 1181 Amps Hi PR Lo PR MBh S/T ∆T kW 1050 Amps Hi PR Lo PR MBh S/T ∆T kW 919 Amps Hi PR Lo PR 29.5 0.80 18 2.05 2.5 240 120 28.7 0.76 19 2.03 2.5 237 119 26.5 0.74 19 1.99 2.3 230 115 63 29.3 0.66 15 2.03 2.5 237 119 28.4 0.63 16 2.02 2.4 235 118 26.2 0.60 16 1.97 2.2 228 114 32.0 0.61 15 2.11 2.8 253 131 31.1 0.58 16 2.09 2.7 251 130 28.7 0.56 16 2.05 2.5 243 126 67 32.0 0.46 11 2.09 2.7 251 130 31.1 0.43 12 2.08 2.6 248 129 28.7 0.42 12 2.03 2.4 241 125 Shaded area is ACCA (TVA) conditions 75 70 IDB* 65ºF 34.3 0.39 10 2.17 3.0 264 140 33.3 0.37 11 2.15 3.0 261 138 30.8 0.36 11 2.11 2.8 254 134 71 28.9 0.83 19 2.19 3.1 269 127 28.0 0.79 19 2.18 3.0 266 126 25.9 0.76 20 2.13 2.8 258 122 63 28.6 0.68 15 2.18 3.0 266 126 27.7 0.65 16 2.16 3.0 264 124 25.6 0.63 16 2.11 2.8 256 121 31.2 0.63 15 2.26 3.4 284 139 30.3 0.60 16 2.24 3.3 281 137 28.0 0.58 16 2.19 3.1 273 133 67 31.3 0.47 11 2.24 3.3 281 137 30.4 0.45 12 2.22 3.2 278 136 28.1 0.43 12 2.17 3.0 270 132 33.5 0.40 11 2.33 3.7 296 148 32.6 0.38 11 2.31 3.6 293 146 30.0 0.37 11 2.26 3.4 285 142 71 27.4 0.95 20 2.28 3.6 284 124 26.6 0.91 21 2.26 3.5 281 123 24.5 0.87 21 2.21 3.3 273 119 28.2 0.85 19 2.32 3.8 306 132 27.4 0.81 19 2.30 3.7 303 131 25.2 0.78 20 2.25 3.5 294 127 30.5 0.64 15 2.39 4.0 323 144 29.6 0.61 16 2.37 4.0 320 143 27.3 0.59 16 2.32 3.7 310 138 32.7 0.41 11 2.47 4.4 337 153 31.8 0.39 11 2.45 4.3 334 152 29.3 0.38 11 2.39 4.0 324 147 27.5 0.88 19 2.44 4.3 348 139 26.7 0.84 20 2.42 4.3 345 137 24.6 0.81 20 2.36 4.0 335 133 29.8 0.66 15 2.51 4.6 368 151 28.9 0.63 16 2.49 4.6 364 150 26.7 0.61 16 2.43 4.3 353 145 31.9 0.43 11 2.59 5.0 384 161 31.0 0.41 11 2.57 4.9 380 160 28.6 0.39 11 2.51 4.6 369 155 71 - SS-SSZ14 25.4 1.00 20 2.48 4.7 364 137 24.6 0.97 21 2.46 4.6 361 135 22.7 0.94 21 2.40 4.4 350 131 59 24.9 0.90 17 2.46 4.6 361 135 24.2 0.85 18 2.44 4.5 357 134 22.3 0.82 18 2.38 4.3 346 130 26.1 0.91 19 2.53 4.9 392 145 25.4 0.87 19 2.51 4.8 388 144 23.4 0.84 20 2.45 4.6 376 140 63 25.8 0.75 15 2.51 4.8 388 144 25.1 0.71 16 2.49 4.7 384 142 23.2 0.69 16 2.43 4.5 373 138 30.3 0.44 10 2.69 5.6 432 169 29.5 0.42 11 2.67 5.5 427 167 27.2 0.41 11 2.61 5.2 415 162 71 23.5 1.00 18 2.56 5.2 402 141 22.8 0.98 20 2.54 5.1 399 140 21.1 0.94 20 2.48 4.9 387 136 59 23.1 0.90 16 2.54 5.1 398 140 22.4 0.86 17 2.52 5.1 394 138 20.7 0.83 17 2.46 4.8 383 134 24.2 0.92 17 2.61 5.5 433 150 23.5 0.88 18 2.59 5.4 429 149 21.7 0.84 18 2.53 5.1 416 144 63 23.9 0.75 14 2.59 5.4 429 149 23.2 0.72 15 2.57 5.3 425 147 21.5 0.69 15 2.51 5.0 412 143 26.2 0.69 14 2.70 5.8 457 164 25.4 0.66 15 2.67 5.7 453 162 23.5 0.64 15 2.61 5.4 439 158 67 26.2 0.52 11 2.67 5.7 453 162 25.5 0.50 11 2.65 5.6 448 161 23.5 0.48 11 2.59 5.3 435 156 115ºF 28.1 0.45 10 2.78 6.2 477 175 27.3 0.43 10 2.76 6.1 472 173 25.2 0.41 10 2.69 5.8 458 168 71 - Amps = outdoor unit amps (comp.+fan) 28.3 0.69 15 2.61 5.2 414 159 27.4 0.66 16 2.59 5.1 410 157 25.3 0.63 16 2.53 4.9 398 152 67 28.3 0.52 11 2.59 5.1 410 157 27.5 0.49 12 2.57 5.1 406 155 25.4 0.48 12 2.51 4.8 394 151 105ºF Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions kW=Total system power 26.7 0.98 20 2.39 4.1 324 130 25.9 0.94 21 2.37 4.1 321 129 23.9 0.90 22 2.31 3.8 311 125 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 26.9 27.9 30.6 26.3 27.2 29.8 0.84 0.70 0.48 0.86 0.72 0.50 18 15 11 18 15 12 2.26 2.30 2.37 2.37 2.42 2.49 3.5 3.7 4.0 4.1 4.3 4.6 281 303 320 321 345 364 123 131 143 129 137 150 26.1 27.1 29.7 25.5 26.4 28.9 0.80 0.67 0.46 0.82 0.69 0.48 18 16 12 18 16 12 2.24 2.29 2.36 2.35 2.40 2.47 3.4 3.6 3.9 4.0 4.2 4.5 279 300 317 317 342 361 122 129 141 128 136 148 24.1 25.0 27.4 23.5 24.4 26.7 0.77 0.64 0.44 0.79 0.66 0.46 19 16 12 19 16 12 2.19 2.23 2.30 2.30 2.34 2.41 3.2 3.4 3.7 3.7 3.9 4.2 270 291 307 308 331 350 118 126 137 124 132 144 IDB: Entering Indoor Dry Bulb Temperature 28.0 0.93 20 2.15 2.9 250 119 27.2 0.88 21 2.14 2.9 248 118 25.1 0.85 21 2.09 2.7 240 115 59 27.6 0.82 17 2.13 2.9 247 118 26.8 0.78 18 2.12 2.8 245 117 24.7 0.75 19 2.07 2.6 238 114 75ºF PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — SSZ140301A* / CA*F3642*6A*+TXV / MBR1600**-1 SS-SSZ14 www.goodmanmfg.com 59 29.2 1.00 23 2.02 2.4 225 114 28.4 0.94 23 2.01 2.4 223 113 26.2 0.90 24 1.97 2.2 216 110 29.7 1.00 23 2.04 2.5 227 115 28.9 0.98 25 2.02 2.4 225 114 26.6 0.95 25 1.98 2.3 218 111 Airflow MBh S/T ∆T 1181 kW Amps Hi PR Lo PR MBh S/T ∆T 1050 kW Amps Hi PR Lo PR MBh S/T ∆T 919 kW Amps Hi PR Lo PR MBh S/T ∆T kW 1181 Amps Hi PR Lo PR MBh S/T ∆T kW 1050 Amps Hi PR Lo PR MBh S/T ∆T kW 919 Amps Hi PR Lo PR 30.3 0.99 23 2.08 2.7 245 123 29.4 0.95 24 2.06 2.6 242 121 27.1 0.91 25 2.02 2.4 235 118 63 29.8 0.92 21 2.06 2.6 242 121 29.0 0.88 22 2.05 2.5 240 120 26.7 0.85 23 2.00 2.4 233 117 31.7 0.90 22 2.14 2.9 258 134 30.8 0.85 23 2.12 2.8 256 133 28.4 0.82 23 2.08 2.6 248 129 67 31.9 0.75 19 2.12 2.8 256 133 31.0 0.71 19 2.11 2.8 253 131 28.6 0.69 20 2.06 2.6 246 127 Shaded area is ARI Rating Conditions 85 80 IDB* 65ºF 33.9 0.73 19 2.20 3.2 269 143 32.9 0.69 20 2.19 3.1 267 141 30.3 0.67 20 2.14 2.9 259 137 71 34.1 0.56 15 2.19 3.1 267 141 33.1 0.53 15 2.17 3.0 264 140 30.5 0.51 16 2.12 2.8 256 136 29.6 1.00 23 2.23 3.3 274 130 28.7 0.98 25 2.21 3.2 272 128 26.5 0.95 25 2.16 3.0 264 124 63 29.2 0.95 22 2.21 3.2 272 128 28.3 0.91 23 2.19 3.1 269 127 26.1 0.88 23 2.14 2.9 261 123 31.0 0.93 22 2.29 3.5 290 141 30.1 0.88 23 2.28 3.4 287 140 27.8 0.85 24 2.22 3.2 278 136 67 31.1 0.78 19 2.28 3.4 287 140 30.2 0.74 20 2.26 3.4 284 139 27.9 0.71 20 2.21 3.2 276 135 33.1 0.75 19 2.36 3.8 302 151 32.1 0.72 20 2.35 3.7 299 149 29.6 0.69 21 2.29 3.5 290 145 71 33.3 0.58 15 2.35 3.7 299 149 32.3 0.55 16 2.33 3.7 296 148 29.8 0.53 16 2.27 3.4 287 143 28.3 1.00 22 2.31 3.7 290 127 27.5 1.00 24 2.29 3.7 287 125 25.4 1.00 25 2.24 3.4 279 122 28.9 1.00 22 2.36 3.9 312 135 28.0 1.00 25 2.34 3.9 309 133 25.9 0.97 25 2.29 3.6 300 129 30.3 0.95 22 2.43 4.2 330 147 29.4 0.91 23 2.41 4.1 326 146 27.1 0.87 24 2.35 3.9 317 141 32.3 0.77 19 2.50 4.5 344 157 31.3 0.74 20 2.49 4.5 340 155 28.9 0.71 21 2.43 4.2 330 150 28.2 1.00 22 2.47 4.5 356 141 27.4 1.00 24 2.45 4.4 352 140 25.3 1.00 25 2.40 4.2 341 136 29.5 0.98 23 2.55 4.8 375 154 28.7 0.94 23 2.53 4.7 372 153 26.4 0.90 24 2.47 4.5 361 148 31.5 0.80 20 2.63 5.2 392 164 30.6 0.76 20 2.61 5.1 388 163 28.2 0.73 21 2.55 4.8 376 158 9 26.3 1.00 20 2.52 4.9 372 139 25.5 1.00 22 2.50 4.8 368 138 23.5 1.00 24 2.44 4.5 357 134 59 25.8 1.00 20 2.50 4.8 368 138 25.1 1.00 22 2.48 4.7 364 137 23.1 1.03 24 2.42 4.4 353 133 26.8 1.00 21 2.57 5.1 400 148 26.0 1.00 23 2.55 5.0 396 147 24.0 1.00 24 2.49 4.7 384 142 63 26.4 1.00 21 2.55 5.0 396 147 25.6 1.00 22 2.53 4.9 392 145 23.6 0.96 23 2.47 4.7 380 141 29.9 0.83 19 2.74 5.8 440 172 29.0 0.79 20 2.71 5.7 436 171 26.8 0.76 20 2.65 5.4 423 166 71 30.1 0.64 15 2.71 5.7 436 171 29.2 0.61 16 2.69 5.6 432 169 27.0 0.59 16 2.63 5.3 419 164 24.3 1.00 19 2.60 5.4 411 144 23.6 1.00 21 2.58 5.3 407 143 21.8 1.00 22 2.52 5.1 394 138 59 23.9 1.00 19 2.58 5.3 407 143 23.2 1.00 20 2.56 5.2 403 141 21.4 1.04 22 2.50 5.0 390 137 24.8 1.00 19 2.66 5.7 442 153 24.1 1.00 21 2.64 5.6 438 152 22.2 1.00 22 2.57 5.3 424 147 63 24.4 1.00 19 2.64 5.6 438 152 23.7 1.00 21 2.61 5.5 433 150 21.9 0.97 21 2.55 5.2 420 146 26.0 1.00 20 2.74 6.0 467 167 25.2 0.98 22 2.72 5.9 462 166 23.3 0.94 22 2.65 5.6 448 161 67 26.1 0.86 17 2.72 5.9 462 166 25.3 0.82 18 2.70 5.8 457 164 23.4 0.79 18 2.63 5.5 444 159 115ºF 27.7 0.83 18 2.83 6.4 487 178 26.9 0.80 19 2.80 6.3 482 177 24.8 0.77 19 2.74 6.0 467 171 71 27.9 0.64 14 2.80 6.3 482 177 27.1 0.61 15 2.78 6.2 477 175 25.0 0.59 15 2.72 5.9 463 170 Amps = outdoor unit amps (comp.+fan) 28.0 1.00 22 2.65 5.4 422 162 27.2 0.97 23 2.63 5.3 418 160 25.1 0.94 24 2.57 5.0 406 155 67 28.2 0.85 19 2.63 5.3 418 160 27.4 0.81 19 2.61 5.2 414 159 25.3 0.78 20 2.55 5.0 402 154 105ºF Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions kW=Total system power 27.6 1.00 22 2.42 4.3 330 133 26.8 1.00 24 2.40 4.2 327 132 24.8 1.00 25 2.35 4.0 317 128 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 71 27.9 28.5 30.4 32.5 27.2 27.8 29.7 31.7 1.00 1.00 0.80 0.59 1.00 1.00 0.82 0.61 22 22 19 15 21 22 19 15 2.29 2.34 2.41 2.49 2.40 2.45 2.53 2.61 3.7 3.9 4.1 4.5 4.2 4.4 4.7 5.1 287 309 326 340 327 352 372 388 125 133 146 155 132 140 153 163 27.0 27.6 29.5 31.6 26.4 27.0 28.8 30.8 0.99 0.93 0.76 0.57 1.00 0.96 0.78 0.59 24 23 20 16 23 23 20 16 2.28 2.32 2.39 2.47 2.39 2.44 2.51 2.59 3.6 3.8 4.0 4.4 4.1 4.3 4.6 5.0 284 306 323 337 324 348 368 384 124 132 144 154 130 139 151 161 25.0 25.5 27.2 29.1 24.3 24.9 26.6 28.4 0.96 0.90 0.73 0.55 0.99 0.93 0.75 0.56 24 23 20 16 24 23 20 16 2.22 2.27 2.34 2.41 2.33 2.38 2.45 2.53 3.4 3.5 3.8 4.1 3.9 4.1 4.4 4.7 276 297 313 327 314 338 357 372 120 128 140 149 126 135 147 156 Outdoor Ambient Temperature IDB: Entering Indoor Dry Bulb Temperature 29.0 1.00 23 2.18 3.1 255 122 28.2 1.00 25 2.17 3.0 253 121 26.0 0.98 25 2.12 2.8 245 117 59 28.5 1.00 22 2.17 3.0 253 121 27.7 0.97 24 2.15 2.9 250 119 25.6 0.93 24 2.10 2.7 243 116 75ºF PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — SSZ140301A* / CA*F3642*6A*+TXV / MBR1600**-1 (CONT.) 10 www.goodmanmfg.com 59 33.9 0.72 19 2.34 8.6 218 105 32.9 0.69 20 2.33 8.6 216 104 30.4 0.67 20 2.28 8.4 210 101 34.5 0.82 22 2.36 8.7 221 106 33.5 0.78 23 2.34 8.7 218 105 30.9 0.76 23 2.29 8.4 212 102 Airflow MBh S/T ∆T 1181 kW Amps Hi PR Lo PR MBh S/T ∆T 1050 kW Amps Hi PR Lo PR MBh S/T ∆T 919 kW Amps Hi PR Lo PR MBh S/T ∆T 1181 kW Amps Hi PR Lo PR MBh S/T ∆T 1050 kW Amps Hi PR Lo PR MBh S/T ∆T kW 919 Amps Hi PR Lo PR 35.5 0.74 20 2.41 8.9 237 113 34.5 0.70 21 2.39 8.8 235 112 31.8 0.68 22 2.34 8.6 228 109 63 35.1 0.60 17 2.39 8.8 235 112 34.1 0.58 17 2.37 8.8 233 111 31.5 0.56 18 2.32 8.5 226 107 38.4 0.56 17 2.48 9.2 251 123 37.3 0.53 17 2.46 9.1 248 122 34.4 0.51 18 2.41 8.9 241 119 67 38.5 0.42 13 2.46 9.1 248 122 37.4 0.40 13 2.44 9.0 246 121 34.5 0.38 13 2.39 8.8 238 117 Shaded area is ACCA (TVA) conditions 75 70 IDB* 65ºF 41.2 0.36 11 2.55 9.5 261 131 40.0 0.34 12 2.54 9.4 259 130 37.0 0.33 12 2.48 9.2 251 126 71 34.7 0.76 21 2.58 9.6 266 119 33.7 0.73 21 2.56 9.5 264 118 31.1 0.70 22 2.51 9.3 256 115 63 34.3 0.63 17 2.56 9.5 264 118 33.3 0.60 17 2.54 9.4 261 117 30.8 0.58 18 2.49 9.2 253 114 37.5 0.58 17 2.66 9.9 281 130 36.4 0.55 18 2.64 9.8 279 129 33.6 0.53 18 2.58 9.6 270 125 67 37.6 0.43 13 2.64 9.8 278 129 36.5 0.41 13 2.62 9.7 276 128 33.7 0.40 13 2.56 9.5 267 124 40.3 0.37 12 2.74 10.3 293 139 39.1 0.35 12 2.72 10.2 290 137 36.1 0.34 12 2.66 9.9 282 133 71 32.9 0.87 22 2.68 10.2 282 117 31.9 0.83 23 2.66 10.1 279 116 29.5 0.80 24 2.60 9.8 270 112 33.8 0.78 21 2.74 10.4 303 124 32.9 0.75 21 2.72 10.3 300 123 30.3 0.72 22 2.65 10.0 291 119 36.6 0.59 17 2.82 10.7 320 136 35.6 0.56 18 2.80 10.6 317 134 32.8 0.54 18 2.73 10.4 307 130 39.3 0.38 12 2.91 11.1 334 144 38.2 0.36 12 2.89 11.0 330 143 35.2 0.35 12 2.82 10.7 320 139 33.0 0.81 21 2.87 11.1 345 130 32.1 0.77 22 2.85 11.0 342 129 29.6 0.74 22 2.78 10.7 331 125 35.7 0.61 17 2.96 11.4 364 142 34.7 0.58 18 2.94 11.3 361 141 32.0 0.56 18 2.87 11.0 350 137 38.4 0.39 12 3.06 11.8 380 152 37.2 0.37 12 3.03 11.7 376 150 34.4 0.36 12 2.96 11.4 365 146 71 - SS-SSZ14 30.5 0.94 22 2.93 11.5 361 128 29.6 0.89 23 2.90 11.4 357 127 27.3 0.86 24 2.84 11.1 346 123 59 30.0 0.82 19 2.90 11.4 357 127 29.1 0.79 20 2.88 11.3 354 126 26.9 0.76 20 2.81 11.0 343 122 31.4 0.84 20 2.99 11.8 388 137 30.5 0.80 21 2.97 11.7 384 135 28.1 0.77 22 2.89 11.3 373 131 63 31.1 0.69 17 2.96 11.7 384 135 30.2 0.66 17 2.94 11.6 380 134 27.8 0.63 18 2.87 11.2 369 130 36.4 0.41 12 3.18 12.6 428 159 35.4 0.39 12 3.16 12.5 423 157 32.7 0.37 12 3.08 12.1 411 153 71 28.2 0.94 21 3.02 12.1 399 133 27.4 0.90 22 3.00 12.0 395 132 25.3 0.87 22 2.93 11.7 383 128 59 27.8 0.83 18 3.00 12.0 395 132 26.9 0.79 19 2.98 11.9 391 130 24.9 0.76 19 2.90 11.6 379 126 29.1 0.84 19 3.09 12.4 429 141 28.2 0.81 20 3.06 12.3 425 140 26.0 0.78 20 2.99 12.0 412 136 63 28.8 0.69 16 3.06 12.3 425 140 27.9 0.66 16 3.04 12.2 420 139 25.8 0.64 16 2.97 11.9 408 134 31.5 0.64 16 3.19 12.8 453 154 30.5 0.61 16 3.16 12.7 448 153 28.2 0.59 17 3.08 12.4 435 148 67 31.5 0.48 12 3.16 12.7 448 153 30.6 0.46 12 3.14 12.6 444 151 28.2 0.44 12 3.06 12.3 431 147 115ºF 33.8 0.41 11 3.29 13.3 472 164 32.8 0.39 11 3.26 13.2 468 163 30.3 0.38 11 3.18 12.8 454 158 71 - Amps = outdoor unit amps (comp.+fan) 34.0 0.63 17 3.08 12.1 410 149 33.0 0.60 17 3.06 12.0 406 148 30.4 0.58 18 2.98 11.7 394 143 67 34.0 0.48 13 3.06 12.0 406 148 33.0 0.45 13 3.03 11.9 402 146 30.5 0.44 13 2.96 11.6 390 142 105ºF Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions kW=Total system power 32.1 0.90 23 2.81 10.8 321 123 31.1 0.86 23 2.79 10.7 317 121 28.7 0.83 24 2.73 10.5 308 118 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 32.3 33.5 36.7 31.5 32.7 35.8 0.77 0.64 0.44 0.79 0.66 0.46 19 17 13 19 17 13 2.66 2.72 2.80 2.79 2.85 2.94 10.1 10.3 10.6 10.7 11.0 11.3 279 300 317 317 342 361 115 123 134 121 129 141 31.4 32.5 35.6 30.6 31.7 34.8 0.73 0.61 0.42 0.76 0.63 0.44 20 17 13 20 18 13 2.64 2.69 2.78 2.77 2.83 2.92 10.0 10.2 10.5 10.6 10.9 11.2 276 297 314 314 338 357 114 122 133 120 128 140 29.0 30.0 32.9 28.3 29.3 32.1 0.71 0.59 0.41 0.73 0.61 0.42 20 18 13 21 18 14 2.58 2.63 2.71 2.71 2.76 2.85 9.7 9.9 10.3 10.4 10.6 10.9 268 288 304 305 328 346 111 118 129 117 124 135 IDB: Entering Indoor Dry Bulb Temperature 33.7 0.85 22 2.53 9.4 248 112 32.7 0.81 23 2.51 9.3 245 111 30.2 0.78 24 2.46 9.1 238 108 59 33.1 0.75 19 2.51 9.3 245 111 32.2 0.71 20 2.49 9.2 243 110 29.7 0.69 20 2.44 9.0 235 107 75ºF PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — SSZ140361A* / CA*F4860*6A*+TXV / MBR1600**-1 SS-SSZ14 www.goodmanmfg.com 59 35.09 0.90 25 2.38 8.8 223 107 34.1 0.86 26 2.36 8.7 221 106 31.4 0.83 26 2.31 8.5 214 103 35.71 0.95 26 2.40 8.9 225 108 34.7 0.90 27 2.38 8.8 223 107 32.0 0.87 28 2.33 8.6 216 104 Airflow MBh S/T ∆T 1181 kW Amps Hi PR Lo PR MBh S/T ∆T 1050 kW Amps Hi PR Lo PR MBh S/T ∆T 919 kW Amps Hi PR Lo PR MBh S/T ∆T kW 1181 Amps Hi PR Lo PR MBh S/T ∆T kW 1050 Amps Hi PR Lo PR MBh S/T ∆T kW 919 Amps Hi PR Lo PR 36.40 0.91 26 2.45 9.1 242 115 35.3 0.87 27 2.43 9.0 240 114 32.6 0.84 27 2.37 8.8 233 111 63 35.86 0.85 24 2.43 9.0 240 114 34.8 0.81 25 2.41 8.9 237 113 32.1 0.78 25 2.36 8.7 230 110 38.12 0.82 24 2.52 9.4 256 126 37.0 0.79 25 2.50 9.3 253 125 34.2 0.76 26 2.44 9.0 246 121 67 38.31 0.69 21 2.50 9.3 253 125 37.2 0.66 21 2.48 9.2 251 123 34.3 0.63 22 2.42 9.0 243 120 Shaded area is ARI Rating Conditions 85 80 IDB* 65ºF 40.67 0.67 21 2.59 9.7 267 134 39.5 0.64 22 2.57 9.6 264 133 36.4 0.61 22 2.52 9.4 256 129 71 40.95 0.51 16 2.57 9.6 264 133 39.8 0.49 17 2.56 9.5 261 131 36.7 0.47 17 2.50 9.3 254 127 35.55 0.95 26 2.62 9.8 272 122 34.5 0.90 27 2.60 9.7 269 121 31.9 0.87 28 2.54 9.4 261 117 63 35.03 0.88 24 2.60 9.7 269 121 34.0 0.84 25 2.58 9.6 266 119 31.4 0.81 25 2.52 9.4 258 116 37.23 0.85 25 2.70 10.1 287 133 36.1 0.81 26 2.68 10.0 284 132 33.4 0.78 26 2.62 9.7 276 128 67 37.42 0.71 21 2.68 10.0 284 132 36.3 0.68 22 2.66 9.9 281 130 33.5 0.66 22 2.60 9.6 273 126 39.72 0.69 21 2.79 10.4 299 142 38.6 0.66 22 2.77 10.3 296 140 35.6 0.64 23 2.70 10.1 287 136 71 40.00 0.53 17 2.77 10.3 296 140 38.8 0.51 17 2.74 10.3 293 139 35.8 0.49 18 2.68 10.0 285 135 34.04 1.00 26 2.72 10.3 287 119 33.1 0.96 28 2.70 10.3 284 118 30.5 0.92 28 2.64 10.0 276 114 34.70 0.97 26 2.78 10.6 309 127 33.7 0.92 27 2.76 10.5 306 125 31.1 0.89 28 2.69 10.2 297 122 36.35 0.87 25 2.87 10.9 326 138 35.3 0.83 26 2.84 10.8 323 137 32.6 0.80 26 2.78 10.5 313 133 38.78 0.71 21 2.96 11.3 340 147 37.6 0.68 22 2.93 11.2 337 146 34.7 0.65 23 2.86 10.9 327 141 33.86 1.00 26 2.92 11.3 352 133 32.9 0.95 27 2.90 11.2 349 132 30.3 0.92 28 2.83 10.9 338 128 35.46 0.90 25 3.01 11.6 372 145 34.4 0.86 26 2.99 11.5 368 144 31.8 0.83 26 2.92 11.2 357 139 37.83 0.73 22 3.11 12.1 388 155 36.7 0.70 22 3.08 12.0 384 153 33.9 0.67 23 3.01 11.6 372 149 11 31.55 1.00 25 2.97 11.7 368 131 30.6 1.00 27 2.95 11.6 364 130 28.3 0.99 28 2.88 11.3 353 126 59 31.01 1.00 24 2.95 11.6 364 130 30.1 0.98 26 2.93 11.5 361 128 27.8 0.94 26 2.86 11.2 350 125 32.16 1.00 25 3.04 12.0 396 139 31.2 0.99 27 3.01 11.9 392 138 28.8 0.95 28 2.94 11.6 380 134 63 31.69 0.96 24 3.01 11.9 392 138 30.8 0.92 25 2.99 11.8 388 137 28.4 0.89 25 2.92 11.5 377 133 35.94 0.76 21 3.23 12.8 436 162 34.9 0.73 22 3.21 12.7 432 160 32.2 0.70 23 3.13 12.4 419 156 71 36.19 0.59 16 3.21 12.7 432 160 35.1 0.56 17 3.18 12.6 428 159 32.4 0.54 17 3.10 12.2 415 154 29.23 1.00 23 3.07 12.4 407 136 28.4 1.00 25 3.05 12.3 403 134 26.2 1.00 26 2.98 11.9 391 130 59 28.73 1.00 22 3.05 12.3 403 134 27.9 0.99 24 3.02 12.2 399 133 25.7 0.95 25 2.95 11.8 387 129 29.79 1.00 23 3.14 12.7 438 144 28.9 1.00 25 3.11 12.5 433 143 26.7 0.96 26 3.04 12.2 420 138 63 29.35 0.97 22 3.11 12.5 433 143 28.5 0.93 23 3.09 12.4 429 141 26.3 0.89 23 3.01 12.1 416 137 31.20 0.94 23 3.24 13.1 462 157 30.3 0.90 24 3.21 13.0 457 156 28.0 0.87 24 3.13 12.6 444 151 67 31.36 0.79 19 3.21 13.0 457 156 30.4 0.75 20 3.19 12.8 453 154 28.1 0.73 20 3.11 12.5 439 150 115ºF 33.29 0.77 20 3.34 13.6 482 168 32.3 0.73 21 3.32 13.4 477 166 29.8 0.71 21 3.24 13.1 463 161 71 33.53 0.59 15 3.32 13.4 477 166 32.5 0.56 16 3.29 13.3 472 164 30.0 0.54 16 3.21 13.0 458 159 Amps = outdoor unit amps (comp.+fan) 33.69 0.94 25 3.13 12.4 418 152 32.7 0.89 26 3.11 12.3 414 151 30.2 0.86 26 3.03 11.9 402 146 67 33.86 0.78 21 3.11 12.3 414 151 32.9 0.75 22 3.08 12.1 410 149 30.3 0.72 22 3.01 11.8 398 145 105ºF Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions kW=Total system power 33.21 1.00 26 2.86 11.0 327 125 32.2 0.99 28 2.84 10.9 324 124 29.8 0.95 28 2.77 10.6 314 120 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 71 33.46 34.19 36.53 39.05 32.64 33.36 35.64 38.10 0.96 0.90 0.73 0.55 1.00 0.93 0.75 0.56 25 24 21 17 25 24 21 17 2.70 2.76 2.84 2.93 2.84 2.90 2.99 3.08 10.3 10.5 10.8 11.2 10.9 11.2 11.5 12.0 284 306 323 337 324 349 368 384 118 125 137 146 124 132 144 153 32.5 33.2 35.5 37.9 31.7 32.4 34.6 37.0 0.91 0.86 0.70 0.52 0.94 0.88 0.72 0.54 26 25 22 17 26 25 22 17 2.68 2.74 2.82 2.91 2.81 2.87 2.96 3.06 10.2 10.4 10.7 11.1 10.8 11.1 11.4 11.8 282 303 320 334 321 345 364 380 117 124 136 144 123 130 142 152 30.0 30.6 32.7 35.0 29.3 29.9 31.9 34.1 0.88 0.83 0.67 0.50 0.91 0.85 0.69 0.52 26 25 22 18 27 26 22 18 2.62 2.67 2.76 2.84 2.75 2.81 2.89 2.98 9.9 10.1 10.4 10.8 10.5 10.8 11.1 11.5 273 294 310 324 311 335 353 369 113 120 131 140 119 126 138 147 IDB: Entering Indoor Dry Bulb Temperature 34.88 0.98 27 2.57 9.6 253 115 33.9 0.93 28 2.55 9.5 250 113 31.3 0.90 28 2.49 9.2 243 110 59 34.28 0.93 25 2.55 9.5 250 113 33.3 0.89 26 2.53 9.4 248 112 30.7 0.86 26 2.47 9.1 240 109 75ºF PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — SSZ140361A* / CA*F4860*6A*+TXV / MBR1600**-1 (CONT.) 12 www.goodmanmfg.com 59 39.2 0.77 18 2.65 9.7 218 107 38.1 0.74 18 2.63 9.6 215 106 35.1 0.71 19 2.58 9.4 209 103 39.9 0.88 20 2.67 9.8 220 108 38.7 0.84 21 2.65 9.7 218 107 35.7 0.81 22 2.60 9.4 211 104 Airflow MBh S/T ∆T 1575 kW Amps Hi PR Lo PR MBh S/T ∆T 1400 kW Amps Hi PR Lo PR MBh S/T ∆T 1225 kW Amps Hi PR Lo PR MBh S/T ∆T kW 1575 Amps Hi PR Lo PR MBh S/T ∆T kW 1400 Amps Hi PR Lo PR MBh S/T ∆T kW 1225 Amps Hi PR Lo PR 41.0 0.79 19 2.73 10.0 236 115 39.8 0.75 20 2.71 9.9 234 114 36.8 0.72 20 2.65 9.7 227 111 63 40.6 0.65 15 2.71 9.9 234 114 39.4 0.62 16 2.69 9.8 232 113 36.4 0.59 16 2.63 9.6 225 110 44.4 0.60 15 2.80 10.3 250 126 43.1 0.57 16 2.78 10.2 247 125 39.8 0.55 16 2.72 10.0 240 121 67 44.5 0.45 12 2.78 10.2 247 125 43.2 0.43 12 2.76 10.1 245 123 39.9 0.41 12 2.70 9.9 237 120 Shaded area is ACCA (TVA) conditions 75 70 IDB* 65ºF 47.7 0.38 11 2.89 10.7 260 134 46.3 0.37 11 2.87 10.6 258 133 42.7 0.35 11 2.80 10.3 250 129 71 40.1 0.82 19 2.92 10.8 265 122 38.9 0.78 20 2.90 10.7 263 121 35.9 0.75 20 2.83 10.4 255 117 63 39.7 0.67 16 2.90 10.7 263 121 38.5 0.64 16 2.88 10.6 260 120 35.6 0.62 16 2.81 10.3 252 116 43.4 0.62 16 3.01 11.1 280 133 42.1 0.59 16 2.98 11.0 277 132 38.9 0.57 17 2.92 10.7 269 128 67 43.5 0.46 12 2.98 11.0 277 132 42.2 0.44 12 2.96 10.9 275 130 39.0 0.43 12 2.89 10.6 266 127 46.6 0.40 11 3.10 11.5 292 142 45.2 0.38 11 3.07 11.4 289 140 41.7 0.37 11 3.00 11.1 281 136 71 38.0 0.94 21 3.03 11.4 280 119 36.9 0.89 22 3.01 11.3 278 118 34.1 0.86 22 2.94 11.0 269 114 39.1 0.84 19 3.09 11.7 302 127 38.0 0.80 20 3.07 11.6 299 125 35.1 0.77 20 3.00 11.3 290 122 42.4 0.63 16 3.18 12.1 319 138 41.1 0.60 16 3.16 12.0 316 137 38.0 0.58 17 3.09 11.6 306 133 45.5 0.41 11 3.28 12.5 332 147 44.1 0.39 11 3.26 12.4 329 146 40.7 0.37 11 3.18 12.1 319 142 38.2 0.86 19 3.24 12.5 344 133 37.1 0.82 20 3.22 12.4 340 132 34.2 0.79 20 3.14 12.0 330 128 41.3 0.65 16 3.34 12.9 363 145 40.1 0.62 16 3.32 12.8 359 144 37.0 0.60 17 3.24 12.4 349 140 44.4 0.42 11 3.45 13.3 379 155 43.1 0.40 11 3.42 13.2 375 153 39.7 0.39 12 3.34 12.9 364 149 71 - SS-SSZ14 35.2 1.00 21 3.30 12.9 359 131 34.2 0.96 21 3.28 12.8 356 130 31.6 0.92 22 3.20 12.5 345 126 59 34.6 0.88 18 3.28 12.8 356 130 33.6 0.84 19 3.25 12.7 352 129 31.0 0.81 19 3.17 12.4 342 125 36.3 0.90 19 3.37 13.3 387 140 35.2 0.86 20 3.34 13.1 383 138 32.5 0.82 20 3.27 12.8 371 134 63 35.9 0.74 15 3.34 13.1 383 138 34.9 0.70 16 3.32 13.0 379 137 32.2 0.68 16 3.24 12.7 368 133 42.1 0.44 11 3.58 14.2 426 162 40.9 0.42 11 3.56 14.1 422 161 37.8 0.40 11 3.47 13.7 409 156 71 32.6 1.00 19 3.41 13.7 397 136 31.7 0.96 20 3.38 13.6 393 134 29.2 0.93 20 3.30 13.2 381 130 59 32.1 0.89 17 3.38 13.6 393 134 31.2 0.85 17 3.36 13.4 389 133 28.8 0.82 18 3.28 13.1 377 129 33.6 0.90 18 3.48 14.0 427 144 32.6 0.86 18 3.45 13.9 423 143 30.1 0.83 19 3.37 13.5 410 139 63 33.3 0.74 14 3.45 13.9 423 143 32.3 0.71 15 3.43 13.8 419 141 29.8 0.68 15 3.35 13.4 406 137 36.4 0.68 15 3.59 14.5 451 158 35.3 0.65 15 3.56 14.4 447 156 32.6 0.63 15 3.48 14.0 433 151 67 36.4 0.51 11 3.56 14.4 447 156 35.4 0.49 11 3.53 14.2 442 154 32.7 0.47 12 3.45 13.8 429 150 115ºF 39.0 0.44 10 3.70 15.0 471 168 37.9 0.42 10 3.68 14.9 466 166 35.0 0.40 11 3.59 14.5 452 161 71 - Amps = outdoor unit amps (comp.+fan) 39.3 0.68 16 3.47 13.7 408 152 38.1 0.65 16 3.45 13.6 404 151 35.2 0.62 16 3.37 13.2 392 146 67 39.3 0.51 12 3.45 13.6 404 151 38.2 0.49 12 3.42 13.4 400 149 35.2 0.47 12 3.34 13.1 388 145 105ºF Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions kW=Total system power 37.1 0.97 21 3.18 12.2 319 125 36.0 0.92 22 3.15 12.1 316 124 33.2 0.89 22 3.08 11.7 307 120 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 37.4 38.7 42.4 36.5 37.8 41.4 0.82 0.69 0.48 0.85 0.71 0.49 18 16 12 18 16 12 3.01 3.07 3.16 3.15 3.22 3.31 11.3 11.6 12.0 12.1 12.4 12.8 278 299 315 316 340 359 118 125 137 124 132 144 36.3 37.6 41.2 35.4 36.7 40.2 0.79 0.66 0.45 0.81 0.68 0.47 19 16 12 19 16 12 2.98 3.04 3.14 3.13 3.19 3.29 11.2 11.5 11.8 12.0 12.2 12.6 275 296 312 313 337 356 117 124 136 123 130 142 33.5 34.7 38.0 32.7 33.9 37.1 0.76 0.63 0.44 0.78 0.65 0.45 19 16 13 19 17 13 2.92 2.97 3.06 3.06 3.12 3.21 10.9 11.2 11.5 11.6 11.9 12.3 267 287 303 304 327 345 113 120 132 119 127 138 IDB: Entering Indoor Dry Bulb Temperature 38.9 0.91 21 2.86 10.5 247 115 37.8 0.87 22 2.84 10.4 244 113 34.9 0.84 22 2.78 10.2 237 110 59 38.3 0.80 18 2.84 10.4 244 113 37.2 0.77 19 2.82 10.4 242 112 34.3 0.74 19 2.76 10.1 234 109 75ºF PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — SSZ140421A* / CA*F4860*6A*+TXV / MBR2000**-1 SS-SSZ14 www.goodmanmfg.com 59 40.6 0.97 23 2.69 9.9 222 110 39.4 0.92 24 2.67 9.8 220 109 36.4 0.89 24 2.61 9.5 213 105 41.3 1.00 24 2.71 9.9 224 111 40.1 0.97 25 2.69 9.9 222 110 37.0 0.93 26 2.63 9.6 215 106 Airflow MBh S/T ∆T 1575 kW Amps Hi PR Lo PR MBh S/T ∆T 1400 kW Amps Hi PR Lo PR MBh S/T ∆T 1225 kW Amps Hi PR Lo PR MBh S/T ∆T kW 1575 Amps Hi PR Lo PR MBh S/T ∆T kW 1400 Amps Hi PR Lo PR MBh S/T ∆T kW 1225 Amps Hi PR Lo PR 42.1 0.98 24 2.77 10.2 241 118 40.9 0.93 25 2.75 10.1 239 117 37.7 0.90 25 2.68 9.8 232 113 63 41.5 0.91 22 2.75 10.1 239 117 40.2 0.86 23 2.73 10.0 237 115 37.1 0.83 23 2.67 9.7 229 112 44.1 0.88 23 2.85 10.5 255 129 42.8 0.84 24 2.83 10.4 252 127 39.5 0.81 24 2.76 10.1 245 123 67 44.3 0.74 19 2.83 10.4 252 127 43.0 0.70 20 2.80 10.3 250 126 39.7 0.68 20 2.74 10.0 242 122 Shaded area is ARI Rating Conditions 85 80 IDB* 65ºF 47.0 0.72 20 2.93 10.9 266 137 45.6 0.68 20 2.91 10.8 263 136 42.1 0.66 21 2.84 10.5 255 131 71 47.3 0.55 15 2.91 10.8 263 136 46.0 0.53 16 2.89 10.7 260 134 42.4 0.51 16 2.82 10.4 253 130 41.1 1.00 24 2.96 11.0 271 124 39.9 0.97 25 2.94 10.9 268 123 36.8 0.93 26 2.87 10.6 260 119 63 40.5 0.94 22 2.94 10.9 268 123 39.3 0.90 23 2.92 10.8 265 122 36.3 0.86 24 2.85 10.5 257 118 43.0 0.91 23 3.05 11.3 286 136 41.8 0.87 24 3.03 11.2 283 134 38.6 0.84 24 2.96 10.9 275 130 67 43.3 0.76 19 3.03 11.2 283 134 42.0 0.73 20 3.01 11.1 280 133 38.8 0.70 20 2.94 10.8 272 129 45.9 0.74 20 3.15 11.7 298 145 44.6 0.71 21 3.12 11.6 295 143 41.2 0.68 21 3.05 11.3 286 139 71 46.2 0.57 15 3.12 11.6 295 143 44.9 0.54 16 3.10 11.5 292 142 41.4 0.53 16 3.03 11.2 284 138 39.4 1.00 23 3.08 11.6 286 122 38.2 1.00 25 3.05 11.5 283 120 35.3 0.99 26 2.98 11.2 275 117 40.1 1.00 23 3.14 11.9 308 129 39.0 0.99 25 3.11 11.8 305 128 36.0 0.95 26 3.04 11.5 296 124 42.0 0.94 23 3.23 12.3 325 141 40.8 0.89 24 3.21 12.2 322 140 37.7 0.86 24 3.13 11.8 312 136 44.8 0.76 20 3.33 12.7 339 150 43.5 0.72 21 3.31 12.6 336 149 40.2 0.70 21 3.23 12.3 326 144 39.1 1.00 23 3.29 12.7 351 136 38.0 1.00 25 3.27 12.6 347 134 35.1 0.99 26 3.19 12.2 337 130 41.0 0.97 23 3.39 13.1 370 148 39.8 0.92 24 3.37 13.0 367 147 36.7 0.89 25 3.29 12.6 356 142 43.7 0.78 20 3.50 13.6 386 158 42.5 0.75 21 3.47 13.5 382 156 39.2 0.72 21 3.39 13.1 371 152 13 36.5 1.00 21 3.35 13.2 367 134 35.4 1.00 23 3.33 13.1 363 132 32.7 1.00 25 3.25 12.7 352 128 59 35.9 1.00 21 3.33 13.1 363 132 34.8 1.00 23 3.30 12.9 359 131 32.1 1.01 24 3.22 12.6 349 127 37.2 1.00 22 3.42 13.5 395 142 36.1 1.00 24 3.40 13.4 391 141 33.3 1.00 25 3.32 13.0 379 137 63 36.6 1.00 21 3.40 13.4 391 141 35.6 0.98 23 3.37 13.3 387 140 32.8 0.95 23 3.29 12.9 375 135 41.5 0.81 20 3.64 14.5 434 165 40.3 0.78 21 3.61 14.3 430 164 37.2 0.75 21 3.53 13.9 417 159 71 41.8 0.63 15 3.61 14.3 430 164 40.6 0.60 16 3.59 14.2 426 162 37.5 0.58 16 3.50 13.8 413 157 33.8 1.00 20 3.46 13.9 405 138 32.8 1.00 22 3.44 13.8 401 137 30.3 1.00 23 3.36 13.4 389 133 59 33.2 1.00 19 3.44 13.8 401 137 32.2 1.00 21 3.41 13.7 397 136 29.8 1.02 23 3.33 13.3 385 132 34.4 1.00 20 3.54 14.3 436 147 33.4 1.00 22 3.51 14.2 432 146 30.9 1.00 23 3.43 13.8 419 141 63 33.9 1.00 20 3.51 14.2 432 146 32.9 0.99 21 3.48 14.0 427 144 30.4 0.96 22 3.40 13.6 414 140 36.1 1.00 21 3.65 14.8 460 161 35.0 0.97 22 3.62 14.6 456 159 32.3 0.93 23 3.53 14.2 442 154 67 36.3 0.85 18 3.62 14.6 456 159 35.2 0.81 19 3.59 14.5 451 158 32.5 0.78 19 3.50 14.1 438 153 115ºF 38.5 0.82 18 3.76 15.3 480 171 37.4 0.78 19 3.73 15.2 475 169 34.5 0.76 20 3.64 14.7 461 164 71 38.8 0.63 14 3.73 15.2 475 169 37.6 0.60 15 3.71 15.0 471 168 34.7 0.58 15 3.62 14.6 456 163 Amps = outdoor unit amps (comp.+fan) 38.9 1.00 23 3.53 13.9 417 155 37.8 0.96 24 3.50 13.8 412 154 34.9 0.92 24 3.42 13.4 400 149 67 39.1 0.84 19 3.50 13.8 412 154 38.0 0.80 20 3.48 13.7 408 152 35.1 0.77 20 3.39 13.3 396 148 105ºF Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions kW=Total system power 38.4 1.00 22 3.23 12.4 326 128 37.3 1.00 24 3.20 12.3 323 126 34.4 1.00 26 3.13 12.0 313 123 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 71 38.7 39.5 42.2 45.1 37.7 38.6 41.2 44.0 1.00 0.96 0.78 0.59 1.00 1.00 0.81 0.60 23 22 19 15 22 23 19 16 3.05 3.11 3.21 3.31 3.20 3.27 3.37 3.47 11.5 11.8 12.2 12.6 12.3 12.6 13.0 13.5 283 305 322 336 323 347 367 382 120 128 140 149 126 134 147 156 37.6 38.4 41.0 43.8 36.6 37.4 40.0 42.8 0.98 0.92 0.75 0.56 1.00 0.95 0.77 0.58 24 23 20 16 24 23 20 16 3.03 3.09 3.18 3.28 3.18 3.24 3.34 3.45 11.4 11.7 12.1 12.5 12.2 12.5 12.9 13.3 280 302 319 332 319 344 363 379 119 127 138 147 125 133 145 155 34.7 35.4 37.8 40.5 33.8 34.6 36.9 39.5 0.94 0.89 0.72 0.54 0.97 0.91 0.74 0.56 25 24 20 16 25 24 21 16 2.96 3.02 3.11 3.21 3.10 3.17 3.26 3.36 11.1 11.4 11.7 12.2 11.9 12.1 12.5 13.0 272 293 309 322 310 333 352 367 116 123 134 143 121 129 141 150 IDB: Entering Indoor Dry Bulb Temperature 40.3 1.00 24 2.91 10.7 252 117 39.1 1.00 26 2.88 10.6 249 116 36.1 0.96 26 2.82 10.3 242 112 59 39.6 1.00 23 2.88 10.6 249 116 38.5 0.95 24 2.86 10.5 247 115 35.5 0.92 25 2.80 10.3 239 111 75ºF PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — SSZ140421A* / CA*F4860*6A*+TXV / MBR2000**-1 (CONT.) 14 www.goodmanmfg.com 59 45.1 0.76 18 2.98 5.9 217 106 43.8 0.73 19 2.96 5.8 215 105 40.4 0.70 19 2.89 5.5 208 102 45.8 0.87 21 3.00 6.0 219 107 44.5 0.83 22 2.98 5.9 217 106 41.1 0.80 22 2.91 5.6 210 103 Airflow MBh S/T ∆T 1744 kW Amps Hi PR Lo PR MBh S/T ∆T 1550 kW Amps Hi PR Lo PR MBh S/T ∆T 1356 kW Amps Hi PR Lo PR MBh S/T ∆T kW 1744 Amps Hi PR Lo PR MBh S/T ∆T kW 1550 Amps Hi PR Lo PR MBh S/T ∆T kW 1356 Amps Hi PR Lo PR 47.2 0.78 19 3.06 6.3 236 114 45.8 0.74 20 3.04 6.2 233 113 42.3 0.71 20 2.97 5.9 226 109 63 46.7 0.64 16 3.04 6.2 233 113 45.4 0.61 16 3.02 6.1 231 112 41.9 0.59 17 2.95 5.8 224 108 51.1 0.59 16 3.15 6.6 249 124 49.6 0.56 16 3.13 6.5 247 123 45.8 0.54 17 3.06 6.2 239 119 67 51.2 0.44 12 3.13 6.5 247 123 49.7 0.42 12 3.10 6.4 244 122 45.9 0.41 13 3.04 6.1 237 118 Shaded area is ACCA (TVA) conditions 75 70 IDB* 65ºF 54.8 0.38 11 3.25 7.0 260 132 53.2 0.36 11 3.22 6.9 257 131 49.1 0.35 12 3.15 6.6 249 127 71 46.1 0.80 20 3.28 7.1 265 120 44.8 0.77 20 3.26 7.0 262 119 41.3 0.74 21 3.18 6.7 254 115 63 45.6 0.66 16 3.26 7.0 262 119 44.3 0.63 17 3.23 6.9 259 118 40.9 0.61 17 3.16 6.6 252 114 49.9 0.61 16 3.38 7.5 279 131 48.4 0.58 17 3.36 7.4 277 130 44.7 0.56 17 3.28 7.1 268 126 67 50.0 0.46 12 3.36 7.4 277 130 48.5 0.44 13 3.33 7.3 274 129 44.8 0.42 13 3.25 7.0 266 125 53.6 0.39 11 3.49 8.0 291 140 52.0 0.37 12 3.46 7.9 289 138 48.0 0.36 12 3.38 7.5 280 134 71 43.7 0.92 21 3.41 7.9 280 117 42.4 0.88 22 3.38 7.7 277 116 39.2 0.85 22 3.30 7.4 269 113 45.0 0.82 20 3.48 8.2 301 125 43.7 0.79 20 3.45 8.1 298 124 40.3 0.76 21 3.37 7.7 289 120 48.7 0.62 16 3.58 8.6 318 136 47.3 0.59 17 3.56 8.5 315 135 43.7 0.57 17 3.47 8.1 305 131 52.3 0.40 11 3.70 9.1 331 145 50.8 0.38 12 3.67 9.0 328 144 46.8 0.37 12 3.58 8.6 318 140 43.9 0.85 20 3.65 9.1 343 131 42.6 0.81 21 3.62 8.9 339 130 39.3 0.78 21 3.54 8.6 329 126 47.5 0.64 16 3.76 9.5 362 143 46.1 0.61 17 3.73 9.4 358 142 42.6 0.59 17 3.65 9.0 348 138 51.0 0.41 11 3.88 10.0 378 153 49.5 0.40 12 3.85 9.9 374 151 45.7 0.38 12 3.76 9.5 363 147 71 40.5 0.99 21 3.72 9.6 358 129 39.3 0.94 22 3.69 9.5 355 128 36.3 0.91 22 3.60 9.1 344 124 59 39.8 0.87 18 3.69 9.5 355 128 38.7 0.83 19 3.66 9.3 351 127 35.7 0.80 19 3.57 8.9 341 123 41.7 0.88 19 3.80 9.9 386 138 40.5 0.84 20 3.77 9.8 382 136 37.4 0.81 21 3.68 9.4 370 132 63 41.3 0.73 16 3.77 9.8 382 136 40.1 0.69 16 3.74 9.7 378 135 37.0 0.67 17 3.65 9.3 367 131 45.1 0.67 16 3.92 10.4 407 150 43.8 0.64 17 3.88 10.3 403 149 40.5 0.61 17 3.79 9.9 391 144 67 45.2 0.50 12 3.88 10.3 403 149 43.9 0.48 12 3.85 10.2 399 147 40.5 0.46 13 3.76 9.7 387 143 105ºF 48.5 0.43 11 4.04 11.0 425 160 47.0 0.41 11 4.01 10.9 421 158 43.4 0.40 12 3.91 10.4 408 154 71 37.5 1.00 20 3.84 10.4 396 134 36.4 0.95 21 3.81 10.3 392 132 33.6 0.92 21 3.72 9.9 380 128 59 36.9 0.88 17 3.81 10.3 392 132 35.8 0.84 18 3.78 10.2 388 131 33.1 0.81 18 3.69 9.7 376 127 38.6 0.89 18 3.92 10.8 426 142 37.5 0.85 19 3.89 10.7 422 141 34.6 0.82 19 3.80 10.2 409 137 63 38.2 0.73 15 3.89 10.7 422 141 37.1 0.70 15 3.86 10.5 418 139 34.3 0.67 16 3.77 10.1 405 135 41.8 0.67 15 4.05 11.3 450 155 40.6 0.64 15 4.01 11.2 445 154 37.5 0.62 16 3.92 10.7 432 149 67 41.9 0.51 11 4.01 11.2 445 154 40.7 0.48 12 3.98 11.0 441 152 37.5 0.47 12 3.89 10.6 428 148 115ºF 44.9 0.43 10 4.18 11.9 469 165 43.6 0.41 11 4.14 11.8 465 164 40.2 0.40 11 4.04 11.3 451 159 71 - kW=Total system power Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions 42.6 0.95 21 3.58 8.7 319 123 41.4 0.91 22 3.55 8.6 315 122 38.2 0.87 23 3.46 8.2 306 118 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 43.0 44.5 48.8 41.9 43.5 47.6 0.81 0.68 0.47 0.84 0.70 0.48 18 16 12 18 16 12 3.38 3.45 3.56 3.55 3.62 3.73 7.7 8.0 8.5 8.6 8.9 9.4 277 298 315 315 339 358 116 124 135 122 130 142 41.7 43.2 47.4 40.7 42.2 46.2 0.77 0.65 0.45 0.80 0.67 0.46 19 17 13 19 17 13 3.36 3.42 3.53 3.52 3.59 3.70 7.6 7.9 8.4 8.5 8.8 9.3 274 295 311 312 336 355 115 122 134 121 129 140 38.5 39.9 43.7 37.6 38.9 42.7 0.75 0.62 0.43 0.77 0.64 0.45 19 17 13 20 17 13 3.28 3.34 3.45 3.44 3.51 3.62 7.3 7.6 8.0 8.1 8.4 8.9 266 286 302 303 326 344 112 119 130 117 125 136 IDB: Entering Indoor Dry Bulb Temperature 44.8 0.90 21 3.22 6.9 246 113 43.5 0.86 22 3.19 6.8 243 112 40.1 0.83 22 3.12 6.4 236 109 59 44.0 0.79 18 3.19 6.8 243 112 42.7 0.75 19 3.17 6.7 241 111 39.5 0.73 19 3.10 6.3 234 107 75ºF PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — SSZ140481A* / CA*F4860*6A*+TXV / MBR2000**-1 SS-SSZ14 SS-SSZ14 www.goodmanmfg.com 47.5 1.00 25 3.05 6.2 224 109 46.1 0.95 26 3.03 6.1 221 108 42.5 0.92 26 2.96 5.8 215 105 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR 1356 1550 1744 59 46.7 0.95 23 3.03 6.1 221 108 45.3 0.91 24 3.00 6.0 219 107 41.8 0.87 25 2.94 5.7 213 104 Airflow MBh S/T ∆T 1744 kW Amps Hi PR Lo PR MBh S/T ∆T 1550 kW Amps Hi PR Lo PR MBh S/T ∆T 1356 kW Amps Hi PR Lo PR 48.4 0.96 25 3.11 6.5 241 116 47.0 0.92 26 3.08 6.4 238 115 43.4 0.88 26 3.02 6.1 231 111 63 47.7 0.89 22 3.08 6.4 238 115 46.3 0.85 23 3.06 6.3 236 114 42.7 0.82 24 2.99 6.0 229 110 50.7 0.87 23 3.20 6.8 254 127 49.2 0.83 24 3.18 6.7 252 125 45.4 0.80 25 3.10 6.4 244 122 67 50.9 0.73 19 3.18 6.7 252 125 49.5 0.69 20 3.15 6.6 249 124 45.6 0.67 21 3.08 6.3 242 121 Shaded area is ARI Rating Conditions 85 80 IDB* 65ºF 54.1 0.70 20 3.30 7.2 265 135 52.5 0.67 21 3.27 7.1 262 134 48.5 0.65 21 3.20 6.8 254 130 71 54.4 0.54 16 3.27 7.1 262 134 52.9 0.52 16 3.25 7.0 260 132 48.8 0.50 17 3.17 6.7 252 128 47.3 1.00 25 3.33 7.4 270 123 45.9 0.95 26 3.31 7.3 267 121 42.4 0.92 26 3.23 6.9 259 118 63 46.6 0.92 23 3.31 7.3 267 121 45.2 0.88 24 3.28 7.1 265 120 41.7 0.85 24 3.21 6.8 257 117 49.5 0.90 23 3.43 7.8 285 134 48.1 0.86 24 3.41 7.6 282 133 44.4 0.83 25 3.33 7.3 274 129 67 49.7 0.75 20 3.41 7.6 282 133 48.3 0.72 21 3.38 7.5 279 131 44.6 0.69 21 3.30 7.2 271 127 52.8 0.73 20 3.54 8.2 297 143 51.3 0.70 21 3.51 8.1 294 141 47.3 0.67 22 3.43 7.8 286 137 71 53.2 0.56 16 3.51 8.1 294 141 51.6 0.54 16 3.49 8.0 291 140 47.7 0.52 17 3.40 7.6 283 136 45.3 1.00 24 3.46 8.1 285 120 43.9 1.00 26 3.43 8.0 282 119 40.6 0.97 27 3.35 7.6 274 115 46.1 1.00 24 3.53 8.4 307 127 44.8 0.97 26 3.51 8.3 304 126 41.3 0.94 26 3.42 7.9 295 122 48.3 0.92 24 3.64 8.8 324 139 46.9 0.88 24 3.61 8.7 321 138 43.3 0.85 25 3.53 8.3 311 134 51.6 0.75 20 3.76 9.4 338 148 50.1 0.71 21 3.73 9.2 335 147 46.2 0.69 22 3.64 8.8 325 142 45.0 1.00 24 3.71 9.3 350 134 43.7 1.00 26 3.68 9.2 346 133 40.3 0.97 27 3.59 8.8 336 129 47.1 0.95 24 3.82 9.8 369 146 45.8 0.91 25 3.79 9.6 366 145 42.2 0.88 25 3.70 9.2 355 140 50.3 0.77 20 3.95 10.3 385 156 48.8 0.74 21 3.91 10.2 381 154 45.1 0.71 22 3.82 9.8 370 150 15 42.0 1.00 22 3.78 9.9 366 132 40.7 1.00 24 3.75 9.7 362 131 37.6 1.00 25 3.66 9.3 351 127 59 41.2 1.00 22 3.75 9.7 362 131 40.0 1.00 24 3.72 9.6 358 129 36.9 1.00 25 3.63 9.2 348 125 42.8 1.00 23 3.86 10.2 393 140 41.5 1.00 25 3.83 10.1 390 139 38.3 1.00 26 3.74 9.7 378 135 63 42.1 1.00 22 3.83 10.1 390 139 40.9 0.97 23 3.80 9.9 386 138 37.8 0.93 24 3.71 9.5 374 133 47.8 0.80 20 4.11 11.3 433 163 46.4 0.76 21 4.07 11.2 429 162 42.8 0.74 21 3.97 10.7 416 157 71 48.1 0.62 16 4.07 11.2 429 162 46.7 0.59 16 4.04 11.0 425 160 43.1 0.57 17 3.94 10.6 412 155 38.9 1.00 20 3.90 10.7 404 136 37.7 1.00 22 3.87 10.6 400 135 34.8 1.00 24 3.78 10.2 388 131 59 38.2 1.00 20 3.87 10.6 400 135 37.1 1.00 22 3.84 10.4 396 134 34.2 1.00 23 3.75 10.0 384 130 39.6 1.00 21 3.99 11.1 435 145 38.5 1.00 23 3.95 11.0 430 144 35.5 1.00 24 3.86 10.5 417 139 63 39.0 1.00 21 3.95 11.0 430 144 37.9 0.98 22 3.92 10.8 426 142 35.0 0.94 22 3.83 10.4 413 138 41.5 1.00 22 4.11 11.6 459 158 40.3 0.95 23 4.08 11.5 454 157 37.2 0.92 23 3.98 11.0 441 152 67 41.7 0.83 18 4.08 11.5 454 157 40.5 0.79 19 4.05 11.3 450 155 37.4 0.77 19 3.95 10.9 436 151 115ºF 44.3 0.81 19 4.25 12.3 479 169 43.0 0.77 20 4.21 12.1 474 167 39.7 0.74 20 4.11 11.6 460 162 71 44.6 0.62 15 4.21 12.1 474 167 43.3 0.59 15 4.18 11.9 469 165 39.9 0.57 16 4.08 11.5 455 160 Amps = outdoor unit amps (comp.+fan) 44.8 0.99 23 3.98 10.7 415 153 43.5 0.94 24 3.95 10.6 411 152 40.1 0.91 25 3.85 10.1 399 147 67 45.0 0.83 20 3.95 10.6 411 152 43.7 0.79 20 3.92 10.4 407 150 40.3 0.76 21 3.82 10.0 395 146 105ºF Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions kW=Total system power 44.2 1.00 23 3.63 9.0 325 126 42.9 1.00 25 3.60 8.8 322 125 39.6 1.00 27 3.52 8.5 312 121 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 71 44.5 45.5 48.6 51.9 43.4 44.3 47.4 50.6 1.00 0.95 0.77 0.58 1.00 1.00 0.80 0.60 23 23 20 16 23 23 20 16 3.43 3.51 3.61 3.73 3.60 3.68 3.79 3.91 8.0 8.3 8.7 9.2 8.8 9.2 9.6 10.2 282 304 321 335 322 346 366 381 119 126 138 147 125 133 145 154 43.2 44.1 47.2 50.4 42.1 43.1 46.0 49.2 0.96 0.90 0.74 0.55 0.99 0.93 0.76 0.57 25 24 21 16 25 24 21 17 3.41 3.48 3.58 3.70 3.58 3.65 3.76 3.88 7.9 8.2 8.6 9.1 8.7 9.1 9.5 10.1 280 301 318 332 319 343 362 378 117 125 136 145 123 131 143 153 39.9 40.7 43.5 46.5 38.9 39.7 42.5 45.4 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 25 24 21 17 25 24 21 17 3.33 3.40 3.50 3.61 3.49 3.56 3.67 3.79 7.5 7.8 8.2 8.7 8.4 8.7 9.1 9.6 271 292 308 322 309 333 351 366 114 121 132 141 120 127 139 148 IDB: Entering Indoor Dry Bulb Temperature 46.4 1.00 24 3.27 7.1 251 115 45.0 0.99 26 3.24 7.0 248 114 41.5 0.95 27 3.17 6.7 241 111 59 45.6 1.00 24 3.24 7.0 248 114 44.2 0.94 25 3.22 6.9 246 113 40.8 0.91 25 3.14 6.6 239 110 75ºF PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — SSZ140481A* / CA*F4860*6A*+TXV / MBR2000**-1 (CONT.) 16 www.goodmanmfg.com 59 55.4 0.74 18 3.63 7.6 219 103 53.8 0.71 19 3.60 7.4 217 102 49.6 0.68 19 3.51 7.1 210 99 56.3 0.84 21 3.66 7.7 221 104 54.7 0.80 22 3.63 7.6 219 103 50.5 0.78 22 3.54 7.2 212 100 Airflow MBh S/T ∆T 2081 kW Amps Hi PR Lo PR MBh S/T ∆T 1850 kW Amps Hi PR Lo PR MBh S/T ∆T 1619 kW Amps Hi PR Lo PR MBh S/T ∆T kW 2081 Amps Hi PR Lo PR MBh S/T ∆T kW 1850 Amps Hi PR Lo PR MBh S/T ∆T kW 1619 Amps Hi PR Lo PR 58.0 0.75 19 3.73 8.0 238 111 56.3 0.72 20 3.70 7.9 236 110 51.9 0.69 20 3.61 7.5 229 106 63 57.4 0.62 16 3.70 7.9 236 110 55.7 0.59 16 3.67 7.8 233 108 51.4 0.57 17 3.58 7.4 226 105 62.7 0.57 16 3.85 8.5 251 121 60.9 0.54 16 3.82 8.4 249 120 56.2 0.53 17 3.73 8.0 241 116 67 62.9 0.43 12 3.82 8.4 249 120 61.0 0.41 12 3.79 8.2 246 118 56.3 0.40 13 3.70 7.8 239 115 Shaded area is ACCA (TVA) conditions 75 70 IDB* 65ºF 67.3 0.37 11 3.98 9.1 262 129 65.4 0.35 11 3.95 8.9 260 127 60.3 0.34 12 3.85 8.5 252 124 71 56.6 0.78 20 4.03 9.2 267 117 55.0 0.75 20 3.99 9.1 265 116 50.7 0.72 21 3.90 8.6 257 112 63 56.1 0.64 16 3.99 9.1 264 116 54.4 0.61 17 3.96 8.9 262 115 50.2 0.59 17 3.86 8.5 254 111 61.3 0.59 16 4.16 9.7 282 128 59.5 0.56 17 4.12 9.6 279 126 54.9 0.54 17 4.02 9.1 271 123 67 61.4 0.45 12 4.12 9.6 279 126 59.6 0.42 13 4.09 9.4 276 125 55.0 0.41 13 3.99 9.0 268 121 65.8 0.38 11 4.30 10.3 294 136 63.9 0.36 12 4.26 10.2 291 135 58.9 0.35 12 4.15 9.7 283 131 71 53.7 0.90 21 4.19 10.1 282 114 52.1 0.86 22 4.16 10.0 280 113 48.1 0.82 23 4.06 9.5 271 110 55.3 0.80 20 4.29 10.5 304 122 53.7 0.77 20 4.25 10.4 301 120 49.5 0.74 21 4.14 9.9 292 117 59.8 0.61 16 4.43 11.1 321 133 58.1 0.58 17 4.39 10.9 318 131 53.6 0.56 17 4.28 10.5 308 127 64.2 0.39 11 4.58 11.8 335 141 62.3 0.37 12 4.54 11.6 331 140 57.5 0.36 12 4.42 11.1 321 136 53.9 0.83 20 4.52 11.7 346 128 52.4 0.79 21 4.48 11.5 343 126 48.3 0.76 21 4.36 11.0 332 123 58.4 0.63 16 4.67 12.3 365 139 56.7 0.60 17 4.63 12.1 362 138 52.3 0.58 17 4.51 11.6 351 134 62.6 0.40 11 4.82 13.0 381 148 60.8 0.38 12 4.78 12.8 377 147 56.1 0.37 12 4.66 12.3 366 143 71 49.8 0.96 21 4.61 12.4 362 126 48.3 0.92 22 4.57 12.2 358 125 44.6 0.88 22 4.45 11.7 347 121 59 48.9 0.85 18 4.57 12.2 358 125 47.5 0.81 19 4.53 12.1 355 123 43.8 0.78 19 4.41 11.6 344 120 51.2 0.86 19 4.71 12.9 389 134 49.7 0.82 20 4.67 12.7 385 132 45.9 0.79 21 4.55 12.2 374 129 63 50.7 0.71 16 4.67 12.7 385 132 49.2 0.67 16 4.63 12.5 382 131 45.4 0.65 17 4.51 12.0 370 127 55.5 0.65 16 4.87 13.5 411 146 53.8 0.62 17 4.83 13.3 407 145 49.7 0.60 17 4.70 12.8 395 140 67 55.6 0.49 12 4.83 13.3 407 145 53.9 0.47 13 4.78 13.1 403 143 49.8 0.45 13 4.66 12.6 391 139 105ºF 59.5 0.42 11 5.03 14.3 429 156 57.8 0.40 11 4.99 14.1 425 154 53.3 0.38 12 4.86 13.5 412 149 71 46.1 0.97 20 4.77 13.5 400 130 44.7 0.92 21 4.73 13.3 396 129 41.3 0.89 21 4.61 12.8 384 125 59 45.3 0.85 17 4.73 13.3 396 129 44.0 0.81 18 4.69 13.2 392 128 40.6 0.78 18 4.57 12.6 380 124 47.5 0.87 18 4.88 14.0 430 138 46.1 0.83 19 4.84 13.8 426 137 42.5 0.80 19 4.71 13.3 413 133 63 47.0 0.71 15 4.83 13.8 426 137 45.6 0.68 15 4.79 13.6 422 136 42.1 0.65 16 4.67 13.1 409 132 51.4 0.66 15 5.04 14.7 454 151 49.9 0.63 16 5.00 14.5 450 150 46.0 0.60 16 4.87 13.9 436 145 67 51.5 0.49 11 5.00 14.5 450 150 50.0 0.47 12 4.96 14.3 445 148 46.1 0.45 12 4.83 13.7 432 144 115ºF 55.1 0.42 10 5.22 15.5 474 161 53.5 0.40 11 5.17 15.3 469 159 49.4 0.39 11 5.04 14.7 455 155 71 - kW=Total system power Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions 52.4 0.93 21 4.42 11.3 322 120 50.9 0.88 22 4.38 11.1 318 119 46.9 0.85 23 4.27 10.6 309 115 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 52.8 54.7 59.9 51.5 53.4 58.5 0.79 0.66 0.46 0.81 0.68 0.47 18 16 12 19 16 12 4.16 4.25 4.39 4.38 4.48 4.63 10.0 10.4 10.9 11.1 11.5 12.1 279 301 318 318 343 362 113 120 131 119 126 138 51.3 53.1 58.2 50.0 51.8 56.8 0.75 0.63 0.44 0.78 0.65 0.45 19 17 13 19 17 13 4.12 4.22 4.35 4.34 4.44 4.59 9.8 10.2 10.8 11.0 11.4 12.0 277 298 314 315 339 358 112 119 130 118 125 137 47.3 49.0 53.7 46.2 47.8 52.4 0.73 0.61 0.42 0.75 0.63 0.43 19 17 13 20 17 13 4.02 4.11 4.24 4.23 4.33 4.47 9.4 9.8 10.3 10.5 10.9 11.5 268 289 305 306 329 347 109 116 126 114 121 133 IDB: Entering Indoor Dry Bulb Temperature 55.0 0.87 21 3.94 8.8 248 110 53.4 0.83 22 3.91 8.7 246 109 49.3 0.80 23 3.81 8.3 238 106 59 54.1 0.77 18 3.91 8.7 246 109 52.5 0.73 19 3.88 8.6 243 108 48.5 0.71 19 3.78 8.2 236 105 75ºF PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — SSZ140601A* / CA*F4860*6A*+TXV / MBE2000**-1 SS-SSZ14 SS-SSZ14 www.goodmanmfg.com 59 57.3 0.93 23 3.69 7.8 223 105 55.6 0.88 24 3.66 7.7 221 104 51.4 0.85 25 3.57 7.3 215 101 58.3 0.97 25 3.72 8.0 226 106 56.6 0.93 26 3.69 7.8 223 105 52.2 0.89 26 3.60 7.4 217 102 Airflow MBh S/T ∆T 2081 kW Amps Hi PR Lo PR MBh S/T ∆T 1850 kW Amps Hi PR Lo PR MBh S/T ∆T 1619 kW Amps Hi PR Lo PR MBh S/T ∆T kW 2081 Amps Hi PR Lo PR MBh S/T ∆T kW 1850 Amps Hi PR Lo PR MBh S/T ∆T kW 1619 Amps Hi PR Lo PR 59.4 0.94 25 3.80 8.3 243 113 57.7 0.89 26 3.76 8.2 240 112 53.3 0.86 26 3.67 7.8 233 108 63 58.6 0.87 22 3.76 8.2 240 112 56.9 0.83 23 3.73 8.0 238 111 52.5 0.80 24 3.64 7.6 231 107 62.2 0.85 23 3.92 8.8 256 123 60.4 0.81 24 3.89 8.6 254 122 55.8 0.78 25 3.79 8.2 246 118 67 62.6 0.71 20 3.89 8.6 254 122 60.7 0.67 20 3.85 8.5 251 121 56.1 0.65 21 3.76 8.1 244 117 Shaded area is ARI Rating Conditions 85 80 IDB* 65ºF 66.4 0.69 20 4.05 9.3 268 131 64.5 0.65 21 4.01 9.2 265 130 59.5 0.63 21 3.91 8.8 257 126 71 66.9 0.53 16 4.01 9.2 265 130 64.9 0.50 16 3.98 9.1 262 129 59.9 0.49 17 3.88 8.6 254 125 58.1 0.97 25 4.09 9.5 273 119 56.4 0.93 26 4.06 9.3 270 118 52.0 0.89 26 3.96 8.9 262 115 63 57.2 0.90 23 4.06 9.3 270 118 55.5 0.86 24 4.03 9.2 267 117 51.3 0.83 24 3.93 8.8 259 113 60.8 0.88 24 4.23 10.0 288 130 59.0 0.84 25 4.19 9.9 285 129 54.5 0.81 25 4.09 9.4 276 125 67 61.1 0.73 20 4.19 9.9 285 129 59.3 0.70 21 4.16 9.7 282 128 54.8 0.67 21 4.06 9.3 274 124 64.9 0.71 20 4.37 10.6 300 139 63.0 0.68 21 4.33 10.5 297 137 58.1 0.65 22 4.22 10.0 288 133 71 65.3 0.55 16 4.33 10.5 297 137 63.4 0.52 16 4.30 10.3 294 136 58.5 0.50 17 4.19 9.9 285 132 55.6 1.00 25 4.26 10.4 288 117 54.0 0.98 26 4.23 10.3 285 115 49.8 0.95 27 4.12 9.8 277 112 56.7 1.00 25 4.36 10.9 310 124 55.0 0.95 26 4.32 10.7 307 123 50.8 0.92 26 4.21 10.2 298 119 59.4 0.90 24 4.50 11.4 327 135 57.6 0.86 25 4.47 11.3 324 134 53.2 0.83 25 4.35 10.8 314 130 63.3 0.73 20 4.66 12.1 341 144 61.5 0.69 21 4.62 11.9 338 143 56.7 0.67 22 4.50 11.4 328 138 55.3 1.00 24 4.59 12.0 353 130 53.7 0.98 26 4.55 11.9 350 129 49.5 0.94 27 4.44 11.4 339 125 57.9 0.93 24 4.75 12.7 373 142 56.2 0.88 25 4.71 12.5 369 141 51.9 0.85 25 4.59 12.0 358 137 61.8 0.75 21 4.91 13.4 389 151 60.0 0.72 21 4.87 13.2 385 150 55.4 0.69 22 4.74 12.6 373 145 17 51.5 1.00 23 4.68 12.8 369 128 50.0 1.00 25 4.64 12.6 365 127 46.2 1.00 26 4.53 12.1 354 123 59 50.6 1.00 22 4.64 12.6 365 127 49.2 1.00 24 4.61 12.4 362 126 45.4 0.97 25 4.49 11.9 351 122 52.5 1.00 23 4.79 13.2 397 137 51.0 1.00 25 4.75 13.0 393 135 47.1 0.98 26 4.63 12.5 381 131 63 51.7 1.00 23 4.75 13.0 393 135 50.2 0.94 24 4.71 12.9 389 134 46.4 0.91 24 4.59 12.3 378 130 58.7 0.78 20 5.12 14.7 437 159 57.0 0.74 21 5.08 14.5 433 157 52.6 0.72 21 4.95 13.9 420 152 71 59.1 0.60 16 5.08 14.5 433 157 57.4 0.57 16 5.03 14.3 429 156 53.0 0.55 17 4.90 13.7 416 151 47.7 1.00 21 4.85 13.9 408 133 46.3 1.00 23 4.81 13.7 404 131 42.8 1.00 24 4.69 13.1 392 127 59 46.9 1.00 21 4.81 13.7 404 131 45.5 1.00 23 4.77 13.5 400 130 42.0 0.98 23 4.65 13.0 388 126 48.7 1.00 21 4.96 14.4 439 141 47.2 1.00 23 4.92 14.2 434 140 43.6 0.99 24 4.79 13.6 421 136 63 47.9 1.00 21 4.92 14.2 434 140 46.5 0.95 22 4.88 14.0 430 138 43.0 0.92 22 4.75 13.4 417 134 51.0 0.97 22 5.13 15.1 463 154 49.5 0.93 23 5.09 14.9 459 153 45.7 0.89 23 4.95 14.3 445 148 67 51.2 0.81 18 5.09 14.9 459 153 49.7 0.77 19 5.04 14.7 454 151 45.9 0.75 19 4.91 14.1 441 147 115ºF 54.4 0.79 19 5.31 15.9 483 164 52.8 0.75 20 5.26 15.7 479 163 48.7 0.72 20 5.12 15.1 464 158 71 54.7 0.61 15 5.26 15.7 479 163 53.2 0.58 15 5.22 15.5 474 161 49.1 0.56 16 5.08 14.9 460 156 Amps = outdoor unit amps (comp.+fan) 55.0 0.96 23 4.95 13.9 419 149 53.4 0.92 24 4.91 13.7 415 148 49.3 0.88 25 4.78 13.1 403 143 67 55.3 0.80 20 4.91 13.7 415 148 53.7 0.77 20 4.87 13.5 411 146 49.5 0.74 21 4.74 13.0 399 142 105ºF Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions kW=Total system power 54.2 1.00 24 4.49 11.6 328 122 52.7 1.00 26 4.45 11.4 325 121 48.6 0.98 27 4.34 10.9 315 118 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 71 54.6 55.8 59.6 63.8 53.3 54.5 58.2 62.2 1.00 0.92 0.75 0.56 1.00 0.95 0.78 0.58 24 23 20 16 24 23 20 16 4.23 4.32 4.47 4.62 4.45 4.55 4.71 4.87 10.3 10.7 11.3 11.9 11.4 11.9 12.5 13.2 285 307 324 338 325 350 369 385 115 123 134 143 121 129 141 150 53.0 54.2 57.9 61.9 51.8 52.9 56.5 60.4 0.94 0.88 0.72 0.54 0.97 0.91 0.74 0.55 25 24 21 16 25 24 21 17 4.19 4.29 4.43 4.58 4.42 4.52 4.67 4.82 10.1 10.5 11.1 11.8 11.3 11.7 12.3 13.0 282 304 321 335 322 346 365 381 114 122 133 141 120 128 139 148 49.0 50.0 53.5 57.1 47.8 48.8 52.1 55.7 0.90 0.85 0.69 0.52 0.93 0.88 0.71 0.53 25 24 21 17 25 24 21 17 4.09 4.18 4.32 4.46 4.31 4.40 4.55 4.70 9.7 10.1 10.6 11.3 10.8 11.2 11.8 12.5 274 295 311 325 312 336 354 370 111 118 129 137 116 124 135 144 IDB: Entering Indoor Dry Bulb Temperature 56.9 1.00 25 4.01 9.1 253 112 55.3 0.96 26 3.97 9.0 251 111 51.0 0.92 27 3.88 8.6 243 108 59 56.0 0.96 24 3.97 9.0 251 111 54.3 0.91 25 3.94 8.8 248 110 50.2 0.88 25 3.84 8.4 241 107 75ºF PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — SSZ140601A* / CA*F4860*6A*+TXV / MBE2000**-1 (CONT.) PRODUCT SPECIFICATIONS EXPANDED HEATING DATA SSZ140181A* / CA*F3131*6A* +TXV / MBR800**-1 MBh ∆T kW Amps COP EER Hi PR Lo PR 65 60 55 50 47 45 22.6 34.9 1.56 7.0 4.23 14.5 385 149 21.4 33.1 1.53 6.5 4.09 14.0 369 138 20.2 31.1 1.50 6.1 3.93 13.4 355 129 18.8 29.1 1.47 5.7 3.75 12.8 339 118 18.0 27.8 1.45 5.5 3.62 12.4 331 112 17.4 26.9 1.44 5.4 3.54 12.1 325 108 Outdoor Ambient Temperature 40 35 30 25 20 17 16.2 25.0 1.41 5.1 3.36 11.5 312 99 14.9 23.1 1.38 4.9 3.16 10.8 300 88 12.8 19.7 1.39 4.7 2.70 9.2 287 80 11.8 18.2 1.36 4.5 2.55 8.7 274 71 10.9 16.8 1.32 4.2 2.40 8.2 263 62 15 10 5 0 -5 -10 10.3 9.9 8.9 7.9 6.9 5.9 4.8 15.8 15.3 13.7 12.1 10.6 9.0 7.4 1.31 1.29 1.26 1.23 1.20 1.17 1.14 4.1 4.1 3.9 3.6 3.4 3.2 2.9 2.30 2.24 2.06 1.87 1.67 1.47 1.23 7.9 7.6 7.0 6.4 5.7 5.0 4.2 257 252 243 234 224 216 208 58 56 47 41 34 30 24 High pressure is measured at the suction service valve ( the larger valve). Low pressure is measured at the gauge port connection. Calculations are based on nominal CFM and 70°F indoor dry bulb. Amps = Outdoor unit amps (comp.+fan) kW = Total system power SSZ140241A* / CA*F3636*6A*+TXV / MBR800**-1 MBh ∆T kW Amps COP EER Hi PR Lo PR 65 60 55 50 47 45 30.2 32.9 2.08 8.1 4.24 14.5 373 143 28.6 31.1 2.04 7.9 4.09 14.0 358 133 26.9 29.3 2.00 7.7 3.93 13.4 344 124 25.1 27.4 1.96 7.5 3.74 12.8 329 114 24.0 26.1 1.94 7.4 3.62 12.4 321 108 23.3 25.3 1.92 7.3 3.54 12.1 315 104 Outdoor Ambient Temperature 40 35 30 25 20 17 21.6 23.5 1.89 7.2 3.35 11.4 303 95 19.9 21.7 1.85 7.1 3.16 10.8 290 85 17.9 19.5 1.87 7.0 2.81 9.6 278 77 16.6 18.0 1.82 6.9 2.65 9.1 266 68 15.2 16.6 1.78 6.8 2.50 8.5 255 60 14.4 15.7 1.76 6.7 2.39 8.2 249 56 High pressure is measured at the suction service valve ( the larger valve). Low pressure is measured at the gauge port connection. Calculations are based on nominal CFM and 70°F indoor dry bulb. 15 10 13.9 15.1 1.74 6.7 2.33 7.9 245 54 12.4 13.5 1.70 6.6 2.14 7.3 235 46 5 0 -5 -10 11.0 9.6 8.2 6.7 12.0 10.5 8.9 7.3 1.66 1.62 1.58 1.54 6.5 6.3 6.2 6.1 1.94 1.73 1.52 1.28 6.6 5.9 5.2 4.4 226 217 209 202 39 33 29 23 Amps = Outdoor unit amps (comp.+fan) kW = Total system power SSZ140301A* / CA*F3642*6A*+TXV / MBR1600**-1 MBh ∆T kW Amps COP EER Hi PR Lo PR 65 60 55 50 47 45 36.5 32.1 2.40 11.8 4.44 15.2 360 137 34.5 30.4 2.36 10.6 4.28 14.6 346 127 32.5 28.6 2.32 9.6 4.10 14.0 332 119 30.4 26.8 2.27 8.7 3.91 13.4 318 110 29.0 25.6 2.25 8.2 3.78 12.9 310 104 28.1 24.8 2.23 8.0 3.69 12.6 304 100 Outdoor Ambient Temperature 40 35 30 25 20 17 26.1 23.0 2.19 7.2 3.50 11.9 292 92 24.1 21.2 2.14 6.6 3.29 11.2 281 82 22.6 19.9 2.20 6.1 3.01 10.3 269 74 20.9 18.4 2.15 5.6 2.84 9.7 257 66 19.2 17.0 2.11 5.1 2.67 9.1 247 58 High pressure is measured at the suction service valve ( the larger valve). Low pressure is measured at the gauge port connection. Calculations are based on nominal CFM and 70°F indoor dry bulb. 18 www.goodmanmfg.com 18.2 16.0 2.08 4.9 2.55 8.7 241 54 15 10 5 17.5 15.4 2.06 4.8 2.48 8.5 236 52 15.7 13.8 2.01 4.3 2.28 7.8 227 44 13.9 12.3 1.97 3.6 2.07 7.1 219 38 0 -5 -10 12.1 10.3 8.5 10.7 9.1 7.5 1.92 1.87 1.83 3.1 2.5 1.8 1.85 1.62 1.36 6.3 5.5 4.6 210 202 195 32 28 22 Amps = Outdoor unit amps (comp.+fan) kW = Total system power SS-SSZ14 PRODUCT SPECIFICATIONS EXPANDED HEATING DATA (CONT.) SSZ140361A* / CA*F4860C6A*+TXV / MBR1600**-1 MBh ∆T kW Amps COP EER Hi PR Lo PR 65 43.5 38.4 3.05 13.8 4.17 14.3 384 144 60 41.2 36.3 2.99 12.8 4.02 13.8 368 134 55 38.8 34.2 2.94 12.0 3.86 13.2 353 125 50 36.2 31.9 2.88 11.3 3.68 12.6 338 115 47 34.6 30.5 2.84 10.9 3.56 12.2 330 109 45 33.5 29.6 2.82 10.7 3.48 11.9 324 105 Outdoor Ambient Temperature 40 35 30 25 20 17 31.1 28.7 28.8 26.6 24.5 23.1 27.5 25.3 25.4 23.5 21.6 20.4 2.76 2.71 2.78 2.72 2.66 2.62 10.1 9.6 9.2 8.9 8.4 8.3 3.30 3.11 3.03 2.86 2.70 2.58 11.3 10.6 10.4 9.8 9.2 8.8 311 299 286 273 262 256 96 86 77 69 61 56 15 22.3 19.6 2.60 8.2 2.51 8.6 251 54 10 20.0 17.6 2.53 7.8 2.31 7.9 242 46 5 17.7 15.6 2.47 7.3 2.10 7.2 233 40 0 15.5 13.6 2.41 6.9 1.87 6.4 223 33 -5 -10 13.2 10.8 11.6 9.5 2.35 2.29 6.4 5.8 1.64 1.38 5.6 4.7 215 208 29 23 15 26.5 17.5 2.87 8.9 2.70 9.2 242 53 10 23.8 15.7 2.81 8.5 2.48 8.5 233 45 5 21.1 13.9 2.74 7.9 2.25 7.7 224 39 0 18.4 12.1 2.68 7.5 2.01 6.9 215 33 -5 -10 15.7 12.8 10.4 8.5 2.61 2.54 6.9 6.3 1.76 1.48 6.0 5.1 207 200 29 23 15 28.3 16.9 3.41 9.0 2.43 8.3 267 51 10 25.4 15.2 3.32 8.3 2.24 7.6 257 43 5 22.5 13.4 3.24 7.4 2.03 6.9 247 37 0 19.6 11.7 3.16 6.6 1.82 6.2 237 32 -5 -10 16.8 13.7 10.0 8.2 3.08 3.00 5.7 4.6 1.59 1.34 5.4 4.6 229 221 28 22 SSZ140421A* / CA*F4860*6A*+TXV / MBR2000**-1 MBh ∆T kW Amps COP EER Hi PR Lo PR 65 51.5 34.1 3.40 15.2 4.44 15.2 370 142 60 48.8 32.3 3.33 14.1 4.28 14.6 354 132 55 45.9 30.4 3.27 13.2 4.11 14.0 341 123 50 42.9 28.4 3.21 12.4 3.92 13.4 326 113 47 41.0 27.1 3.17 12.0 3.79 12.9 318 107 45 39.7 26.3 3.14 11.8 3.70 12.6 312 103 Outdoor Ambient Temperature 40 35 30 25 20 17 36.9 34.0 34.3 31.6 29.1 27.5 24.4 22.5 22.7 20.9 19.3 18.2 3.08 3.02 3.07 3.00 2.94 2.90 11.1 10.6 10.1 9.7 9.2 9.0 3.50 3.30 3.26 3.08 2.90 2.78 12.0 11.3 11.2 10.5 9.9 9.5 300 288 276 263 253 247 95 84 76 68 60 56 SSZ140481A* / CA*F4860*6A*+TXV / MBR2000**-1 MBh ∆T kW Amps COP EER Hi PR Lo PR 65 57.8 34.5 3.98 19.4 4.25 14.5 408 136 60 54.7 32.7 3.90 17.6 4.10 14.0 391 126 55 51.5 30.8 3.83 16.1 3.94 13.5 376 118 50 48.2 28.8 3.75 14.8 3.76 12.8 359 109 47 46.0 27.5 3.71 14.1 3.63 12.4 351 103 45 44.6 26.6 3.68 13.7 3.55 12.1 344 99 Outdoor Ambient Temperature 40 35 30 25 20 17 41.4 38.2 36.6 33.8 31.1 29.4 24.7 22.8 21.9 20.2 18.6 17.6 3.60 3.53 3.65 3.57 3.49 3.44 12.7 11.7 11.0 10.3 9.5 9.2 3.36 3.17 2.94 2.77 2.61 2.50 11.5 10.8 10.0 9.5 8.9 8.5 331 318 304 291 279 272 91 81 73 65 57 53 SSZ140601A* / CA*F4860*6A*+TXV / MBE2000**-1 MBh ∆T kW Amps COP EER Hi PR Lo PR 65 57.8 35.9 4.8 24.7 4.3 14.8 404 136 60 57.8 33.9 4.7 22.3 4.2 14.3 387 126 55 57.8 32.0 4.6 20.4 4.0 13.8 372 119 50 57.8 29.9 4.5 18.8 3.8 13.1 356 109 47 57.0 28.5 4.5 17.9 3.7 12.7 347 103 45 55.2 27.6 4.4 17.4 3.6 12.4 341 99 Outdoor Ambient Temperature 40 35 30 25 20 17 15 10 5 0 -5 -10 51.3 47.3 47.9 44.2 40.7 38.4 37.0 33.2 29.4 25.7 21.9 17.9 25.7 23.7 24.0 22.1 20.4 19.2 18.5 16.6 14.7 12.8 11.0 9.0 4.3 4.2 4.4 4.3 4.2 4.2 4.1 4.0 3.9 3.8 3.7 3.6 16.0 14.8 13.9 12.9 12.0 11.5 11.3 10.4 9.2 8.2 7.1 5.7 3.5 3.3 3.2 3.0 2.8 2.7 2.6 2.4 2.2 2.0 1.7 1.5 11.8 11.1 10.8 10.2 9.7 9.3 9.0 8.3 7.5 6.8 5.9 5.0 327 314 301 288 276 269 265 255 245 235 226 218 91 81 73 65 57 53 51 43 37 32 28 22 High pressure is measured at the suction service valve ( the larger valve). Low pressure is measured at the gauge port connection. Calculations are based on nominal CFM and 70°F indoor dry bulb. SS-SSZ14 www.goodmanmfg.com Amps = Outdoor unit amps (comp.+fan) kW = Total system power 19 20 SSZ14 0181A* Outdoor Unit Indoor Units 19,000 19,000 19,000 19,000 19,000 19,000 19,000 18,000 MBE1200**-1 MBR0800**-1 G*V80704B** G*V950453B** AEPF183016C*+TXV AR*F193116B*+TXV ARPF193116A*+TXV ARUF193116A*+TXV ASPF183016A*+TXV ASPF183016B*+TXV AT*F193116A*+TXV CA*F036*4*+TXV CA*F036*4*+TXV CA*F036*4*+TXV CA*F036*4*+TXV 18,000 MBE1200**-1 MBR0800**-1 G*E80704B** G*V80704B** G*V950453B** CA*F3131*6A*+TXV CA*F3131*6A*+TXV CA*F3131*6A*+TXV CA*F3131*6A*+TXV CA*F3131*6A*+TXV 18,000 MBE1200**-1 MBR0800**-1 G*E80704B** G*V80704B** G*V950453B** CA*F3131*6B*+TXV CA*F3131*6B*+TXV CA*F3131*6B*+TXV CA*F3131*6B*+TXV www.goodmanmfg.com CA*F3131*6B*+TXV MBR0800**-1 G*E80704B** G*V80704B** G*V950453B** MBR0800**-1 G*V80704B** G*V950453B** CA*F3131*6C*+TXV CA*F3131*6C*+TXV CA*F3131*6C*+TXV CA*F3131*6C*+TXV CHPF036B4*+TXV CHPF036B4*+TXV CHPF036B4*+TXV G*E80704B** G*V80704B** G*V950453B** CHPF2430B6A*+TXV CHPF2430B6A*+TXV CHPF2430B6A*+TXV 18,000 18,000 18,000 19,000 18,000 CHPF2430B6A*+TXV 18,000 18,000 18,000 18,000 18,000 18,000 CHPF2430B6A*+EEP+TXV MBR0800**-1 18,000 MBE1200**-1 CA*F3131*6C*+TXV 18,000 19,000 CA*F3131*6C*+EEP+TXV 18,000 18,000 18,000 18,000 19,000 CA*F3131*6B*+EEP+TXV 18,000 18,000 18,000 18,000 19,000 CA*F3131*6A*+EEP+TXV 18,000 18,000 18,000 19,000 13,100 13,100 13,100 13,100 13,900 13,100 13,100 13,100 13,100 13,100 13,100 13,100 13,100 13,900 13,100 13,100 13,100 13,100 13,100 13,900 13,100 13,100 13,100 13,100 13,100 13,900 13,100 13,100 13,100 13,100 13,900 13,900 13,900 13,900 13,900 13,900 13,900 13,900 13,900 Sens. 15.00 15.00 15.00 14.00 14.00 15.00 15.00 14.00 15.00 15.00 15.00 14.00 15.00 14.00 15.00 15.00 15.00 14.00 15.00 14.00 15.00 15.00 15.00 14.00 15.00 14.00 15.00 15.00 14.00 15.00 14.50 15.00 15.00 14.50 14.50 14.50 15.00 15.00 15.00 SEER¹ 12.50 12.50 12.50 12.00 12.00 12.50 12.50 12.00 12.50 12.50 12.50 12.00 12.50 12.00 12.50 12.50 12.50 12.00 12.50 12.00 12.50 12.50 12.50 12.00 12.50 12.00 12.50 12.50 12.00 12.50 12.50 13.00 13.00 12.50 12.50 12.50 13.00 13.00 13.00 EER² Cooling Capacity (BTU/h) 19,000 Total AEPF183016B*+TXV Furnace/Blower AEPF183016A*+TXV Indoor Coil 16,700 16,700 16,700 16,700 17,600 16,700 16,700 16,700 16,700 16,700 16,700 16,700 16,700 17,600 16,700 16,700 16,700 16,700 16,700 17,600 16,700 16,700 16,700 16,700 16,700 17,600 16,700 16,700 16,700 16,700 17,600 17,600 17,600 17,600 17,600 17,600 17,600 17,600 17,600 13,000 13,000 13,000 13,000 13,700 13,000 13,000 13,000 13,000 13,000 13,000 13,000 13,000 13,700 13,000 13,000 13,000 13,000 13,000 13,700 13,000 13,000 13,000 13,000 13,000 13,700 13,000 13,000 13,000 13,000 13,700 13,700 13,700 13,700 13,700 13,700 13,700 13,700 13,700 Sens. TVA Ratings³ Total 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 High 8.10 8.10 8.10 8.10 8.50 8.10 8.10 8.10 8.10 8.10 8.10 8.10 8.10 8.30 8.10 8.10 8.10 8.10 8.10 8.30 8.10 8.10 8.10 8.10 8.10 8.30 8.10 8.10 8.10 8.10 8.50 8.50 8.50 8.30 8.50 8.50 8.50 8.50 8.50 HSPF4 10,200 10,200 10,200 10,200 10,400 10,200 10,200 10,200 10,200 10,200 10,200 10,200 10,200 10,400 10,200 10,200 10,200 10,200 10,200 10,400 10,200 10,200 10,200 10,200 10,200 10,400 10,200 10,200 10,200 10,200 10,200 10,400 10,400 10,000 10,200 10,200 10,400 10,400 10,400 Low Heating Capacity (BTU/h) 923720 923175 1273336 1031678 1346405 924123 923192 1032311 1401058 1401057 1401056 1386246 1386244 1401051 1346746 1346745 1346744 1346743 1346742 1346741 921384 921345 1273335 922564 922696 1038376 923530 924330 1031677 924364 1483553 1492623 1288545 1032058 1038366 1492622 1492621 1277858 1044179 ARI # PRODUCT SPECIFICATIONS ARI PERFORMANCE RATINGS See Notes on Page 24. SS-SSZ14 SS-SSZ14 SSZ14 0241A* SSZ14 0181A* (cont.) Outdoor Unit Indoor Units G*V80704B** G*V950453B** CT*F3131*6A*+TXV www.goodmanmfg.com 22,800 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 MBE1200**-1 MBR0800**-1 G*V80704B** G*V950453B** AEPF183016C*+TXV AEPF303616A*+TXV AEPF303616B*+TXV AEPF303616C*+TXV AR*F193116B*+TXV ARPF193116A*+TXV ARUF193116A*+TXV ASPF303616A*+TXV ASPF303616B*+TXV AT*F193116A*+TXV CA*F048*4*+TXV CA*F048*4*+TXV CA*F048*4*+TXV CA*F048*4*+TXV MBR0800**-1 G*E80704B** G*V80704B** G*V950453B** CA*F3636*6A*+TXV CA*F3636*6A*+TXV CA*F3636*6A*+TXV CA*F3636*6A*+TXV CA*F3636*6A*+TXV 24,000 24,000 CA*F3636*6B*+TXV 23,600 23,600 23,600 24,000 CA*F3636*6B*+EEP+TXV MBE1200**-1 MBE1600**-1 CA*F3636*6A*+TXV 24,400 24,000 24,000 MBE1200**-1 CA*F3636*6A*+EEP+TXV 23,600 23,600 24,000 22,800 AEPF183016B*+TXV 18,000 18,000 18,000 18,000 CT*F3131*6A*+TXV 18,000 18,000 G*E80704B** G*V950453B** CSCF3036N6B*+TXV MBR0800**-1 G*V80704B** CSCF3036N6B*+TXV 18,000 CT*F3131*6A*+TXV G*E80704B** CSCF3036N6B*+TXV 18,000 CT*F3131*6A*+TXV G*V950453B** CSCF3036N6A*+TXV 18,000 18,000 G*V80704B** CSCF3036N6A*+TXV 18,000 MBE1200**-1 G*E80704B** CSCF3036N6A*+TXV 18,000 CT*F3131*6A*+TXV G*V950453B** CHPF2430B6B*+TXV 18,000 18,000 18,000 18,000 17,700 17,700 17,700 18,000 18,300 18,000 18,000 17,700 17,700 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 17,100 17,100 13,100 13,100 13,100 13,100 13,100 13,900 13,100 13,100 13,100 13,100 13,100 13,100 13,100 13,100 13,100 Sens. 15.00 14.00 14.50 14.50 15.00 14.00 15.00 15.00 14.00 14.50 14.50 14.00 15.00 14.00 15.00 15.00 14.00 14.00 14.00 15.00 15.00 15.00 14.50 14.50 15.00 15.00 15.00 14.00 15.00 14.00 15.00 15.00 15.00 15.00 15.00 15.00 15.00 15.00 15.00 SEER¹ 12.50 12.00 12.20 12.20 12.50 12.00 13.00 12.50 12.00 12.20 12.20 12.00 12.50 12.00 13.00 13.00 12.00 12.00 12.00 13.00 13.00 13.00 12.20 12.20 12.50 12.50 12.50 12.00 12.50 12.00 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 EER² Cooling Capacity (BTU/h) 19,000 G*V80704B** Total CT*F3131*6A*+EEP+TXV G*E80704B** CHPF2430B6B*+TXV Furnace/Blower CHPF2430B6B*+TXV Indoor Coil 22,200 22,200 21,800 21,800 21,800 22,200 22,600 22,200 22,200 21,800 21,800 22,200 22,200 22,200 22,200 22,200 22,200 22,200 22,200 22,200 22,200 22,200 21,100 21,100 16,700 16,700 16,700 16,700 16,700 17,600 16,700 16,700 16,700 16,700 16,700 16,700 16,700 16,700 16,700 17,800 17,800 17,400 17,400 17,400 17,800 18,100 17,800 17,800 17,400 17,400 17,800 17,800 17,800 17,800 17,800 17,800 17,800 17,800 17,800 17,800 17,800 16,900 16,900 13,000 13,000 13,000 13,000 13,000 13,700 13,000 13,000 13,000 13,000 13,000 13,000 13,000 13,000 13,000 Sens. TVA Ratings³ Total 24,000 24,400 23,600 23,000 23,000 24,000 22,000 24,000 24,400 23,600 23,000 24,000 24,000 24,000 22,000 22,000 24,000 24,000 24,000 24,000 24,000 24,000 23,600 23,600 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 High 8.30 8.50 8.30 8.30 8.30 8.30 8.50 8.30 8.50 8.30 8.30 8.30 8.30 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.30 8.30 8.10 8.10 8.10 8.10 8.10 8.30 8.10 8.10 8.10 8.10 8.10 8.10 8.10 8.10 8.10 HSPF4 14,500 14,000 14,500 14,500 14,500 14,500 12,000 14,500 14,000 14,500 14,500 14,500 14,500 14,000 12,000 12,000 14,000 14,000 14,000 14,000 14,000 14,000 14,500 14,500 10,200 10,200 10,200 10,200 10,200 10,400 10,200 10,200 10,200 10,200 10,200 10,200 10,200 10,200 10,200 Low Heating Capacity (BTU/h) 1346748 1346747 1031675 922648 1273338 924184 1293996 923868 1038377 1032303 921724 923995 923423 1483554 1443988 1288546 1032059 1038364 1492625 1443961 1277866 1044180 1492624 1412587 1450090 1450089 1450088 1450087 1450086 1450085 1296659 1296658 1296657 922937 923401 1273337 1330424 1330423 1347586 ARI # PRODUCT SPECIFICATIONS ARI PERFORMANCE RATINGS (CONT.) See Notes on Page 24. 21 22 www.goodmanmfg.com SSZ14 0301A* SSZ14 0241A* (cont.) Outdoor Unit Indoor Units G*V950453B** 24,000 MBE1200**-1A G*E80704B** G*V80704B** G*V950453B** G*E80704B** G*V80704B** G*V950453B** G*E80704B** G*V80704B** G*V950453B** MBE1200**-1 MBE1600**-1 MBR0800**-1 G*E80704B** G*V80704B** CHPF3636B6B*+TXV CHPF3636B6B*+TXV CHPF3636B6B*+TXV CHPF3636B6B*+TXV CSCF3036N6A*+TXV CSCF3036N6A*+TXV CSCF3036N6A*+TXV CSCF3036N6B*+TXV CSCF3036N6B*+TXV CSCF3036N6B*+TXV CT*F3636*6A*+TXV CT*F3636*6A*+TXV CT*F3636*6A*+TXV CT*F3636*6A*+TXV CT*F3636*6A*+TXV 28,800 28,800 30,000 ARPF193116A*+TXV ARUF193116A*+TXV ASPF303616A*+TXV 27,000 28,800 AR*F193116B*+TXV 27,000 30,000 AEPF303616C*+TXV AR*F303016B*+TXV 30,000 AEPF303616B*+TXV AR*F303016A*+TXV 30,000 AEPF303616A*+TXV 23,600 23,600 24,000 24,400 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 CHPF3636B6B*+EEP+TXV 24,000 24,000 24,000 CHPF3636B6A*+TXV 24,000 G*V80704B** MBE1200**-1 CHPF3636*6A*+TXV 23,600 CHPF3636B6A*+TXV G*V950704C** CA*F3636*6B*+TXV 23,600 24,000 G*V950453B** CA*F3636*6B*+TXV 23,600 23,600 G*E80704B** G*V80704B** CA*F3636*6B*+TXV MBR0800**-1 G*E80704B** CA*F3636*6B*+TXV 23,800 CHPF3636B6A*+TXV A*V90704C** CA*F3636*6B*+TXV 23,600 CHPF3636B6A*+TXV A*V90453B** CA*F3636*6B*+TXV 24,000 24,400 23,400 22,500 22,500 21,100 21,100 22,500 23,400 23,400 23,400 17,700 17,700 18,000 18,300 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 17,700 17,700 17,700 17,700 17,900 17,700 18,000 18,300 Sens. 15.00 14.00 14.00 13.50 13.50 14.00 15.00 15.00 15.00 14.50 15.00 14.00 15.00 15.00 14.50 14.50 15.00 14.50 14.50 15.00 14.50 14.50 15.00 14.00 14.00 14.50 14.50 15.00 14.00 14.00 14.00 14.50 14.50 14.50 15.00 15.00 14.50 14.00 15.00 SEER¹ 13.00 12.00 12.00 11.00 11.00 12.00 13.00 13.00 13.00 12.20 12.50 12.00 13.00 12.50 12.20 12.20 12.50 12.20 12.20 12.50 12.20 12.20 12.50 12.00 12.00 12.20 12.20 12.50 12.00 12.00 12.00 12.20 12.20 12.20 12.50 12.70 12.20 12.00 13.00 EER² Cooling Capacity (BTU/h) 24,000 MBR0800**-1 Total CHPF3636B6A*+EEP+TXV MBE1600**-1 CA*F3636*6B*+TXV Furnace/Blower CA*F3636*6B*+TXV Indoor Coil 27,800 26,600 26,600 25,000 25,000 26,600 27,800 27,800 27,800 21,800 21,800 22,200 22,600 22,200 22,200 22,200 22,200 22,200 22,200 22,200 22,200 22,200 22,200 22,200 22,200 22,200 22,200 22,200 22,200 22,200 22,200 21,800 21,800 21,800 21,800 22,000 21,800 22,200 22,600 23,400 22,300 22,300 21,000 21,000 22,300 23,400 23,400 23,400 17,400 17,400 17,800 18,100 17,800 17,800 17,800 17,800 17,800 17,800 17,800 17,800 17,800 17,800 17,800 17,800 17,800 17,800 17,800 17,800 17,800 17,800 17,400 17,400 17,400 17,400 17,600 17,400 17,800 18,100 Sens. TVA Ratings³ Total 28,000 28,000 28,000 23,000 23,000 28,000 28,000 28,000 28,000 23,000 23,000 24,000 22,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,400 24,000 24,000 24,000 24,000 24,400 24,000 23,000 23,600 23,000 23,000 23,600 23,600 24,000 22,000 High 8.50 8.50 8.50 8.30 8.30 8.50 8.50 8.50 8.50 8.30 8.30 8.30 8.50 8.30 8.30 8.30 8.30 8.30 8.30 8.30 8.30 8.30 8.30 8.30 8.50 8.30 8.30 8.30 8.30 8.50 8.30 8.30 8.30 8.30 8.30 8.30 8.30 8.30 8.50 HSPF4 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 14,500 14,500 14,500 12,000 14,500 14,500 14,500 14,500 14,500 14,500 14,500 14,500 14,500 14,500 14,500 14,000 14,500 14,500 14,500 14,500 14,000 14,500 14,500 14,500 14,500 14,500 14,500 14,500 14,500 12,000 Low Heating Capacity (BTU/h) 1288547 1044492 1044493 1492627 1464061 1492626 1443962 1277867 1044181 1450095 1450094 1450093 1450092 1450091 1296662 1296661 1296660 924031 922578 1273340 1330427 1330426 1347589 1330425 1330361 925020 922275 1273339 1032305 1038815 923997 1464060 1347232 1346752 1346751 1444039 1430182 1346750 1346749 ARI # PRODUCT SPECIFICATIONS ARI PERFORMANCE RATINGS (CONT.) See Notes on Page 24. SS-SSZ14 SS-SSZ14 SSZ14 0301A* (cont.) Outdoor Unit Indoor Units 27,000 28,800 MBE1600**-1 MBR1600**-1 G*V80905C** G*V81155C** AT*F303016A*+TXV CA*F057*4*+TXV CA*F057*4*+TXV CA*F057*4*+TXV CA*F057*4*+TXV 28,800 MBE1200**-1 G*V950453B** G*V950704C** CA*F3636*6A*+TXV CA*F3636*6A*+TXV CA*F3636*6A*+TXV G*V950453B** G*V950704C** CA*F3636*6B*+TXV CA*F3636*6B*+TXV CA*F3636*6B*+TXV MBR1600**-1 G*E80905C** G*E81155C** G*V80905C** G*V81155C** G*V950704C** CA*F3642*6A*+TXV CA*F3642*6A*+TXV CA*F3642*6A*+TXV CA*F3642*6A*+TXV CA*F3642*6A*+TXV CA*F3642*6A*+TXV CA*F3642*6A*+TXV www.goodmanmfg.com MBR1600**-1 G*E80905C** G*E81155C** G*V80905C** G*V81155C** G*V950704C** G*V80905C** G*V81155C** G*V950704C** MBE1600**-1 MBR1600**-1 G*E80905C** G*E81155C** G*V80905C** CA*F3743*6A*+TXV CA*F3743*6A*+TXV CA*F3743*6A*+TXV CA*F3743*6A*+TXV CA*F3743*6A*+TXV CA*F3743*6A*+TXV CA*F3743*6A*+TXV CHPF048*4*+TXV CHPF048*4*+TXV CHPF048*4*+TXV CHPF048D4*+TXV CHPF048D4*+TXV CHPF3642*6A*+TXV CHPF3642*6A*+TXV CHPF3642*6A*+TXV 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,400 28,800 MBE1600**-1 CA*F3743*6A*+EEP+TXV 28,800 28,800 28,800 28,800 28,800 28,800 28,400 28,800 MBE1600**-1 CA*F3642*6A*+EEP+TXV 28,800 28,800 28,800 28,800 MBE1200**-1 CA*F3636*6B*+EEP+TXV 28,800 28,800 28,800 CA*F3636*6A*+EEP+TXV 28,800 28,800 28,800 28,800 22,500 22,500 22,500 22,500 22,500 22,500 22,500 22,500 22,500 22,500 22,500 22,500 22,500 22,500 22,500 22,200 22,500 22,500 22,500 22,500 22,500 22,500 22,500 22,200 22,500 22,500 22,500 22,500 22,500 22,500 22,500 22,500 22,500 22,500 22,500 22,500 21,100 22,500 23,400 Sens. 14.50 14.50 14.50 14.00 15.00 14.50 14.50 14.50 14.50 14.50 14.50 14.50 14.50 14.00 15.00 14.00 14.50 14.50 14.50 14.50 14.50 14.00 15.00 14.00 15.00 15.00 15.00 14.00 15.00 15.00 15.00 14.00 14.50 14.50 14.00 15.00 13.50 14.00 15.00 SEER¹ 12.20 12.20 12.20 12.00 12.50 12.20 12.20 12.20 12.00 12.20 12.20 12.20 12.20 12.00 12.50 12.00 12.00 12.20 12.20 12.20 12.20 12.00 12.50 12.00 12.00 12.00 13.00 12.00 12.00 12.00 13.00 12.00 12.20 12.20 12.00 12.50 11.00 12.00 13.00 EER² Cooling Capacity (BTU/h) 30,000 Total AT*F193116A*+TXV Furnace/Blower ASPF303616B*+TXV Indoor Coil 26,600 26,600 26,600 26,600 26,600 26,600 26,600 26,600 26,600 26,600 26,600 26,600 26,600 26,600 26,600 26,300 26,600 26,600 26,600 26,600 26,600 26,600 26,600 26,300 26,600 26,600 26,600 26,600 26,600 26,600 26,600 26,600 26,600 26,600 26,600 26,600 25,000 26,600 27,800 22,300 22,300 22,300 22,300 22,300 22,300 22,300 22,300 22,300 22,300 22,300 22,300 22,300 22,300 22,300 22,100 22,300 22,300 22,300 22,300 22,300 22,300 22,300 22,100 22,300 22,300 22,300 22,300 22,300 22,300 22,300 22,300 22,300 22,300 22,300 22,300 21,000 22,300 23,400 Sens. TVA Ratings³ Total 29,000 29,000 29,000 29,000 29,000 29,000 29,000 29,000 28,000 29,000 29,000 29,000 29,000 29,000 29,000 28,800 28,000 29,000 29,000 29,000 29,000 29,000 29,000 28,800 28,000 28,000 28,000 28,000 28,000 28,000 28,000 28,000 29,000 29,000 29,000 29,000 23,000 28,000 28,000 High 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.30 8.50 8.50 HSPF4 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 Low Heating Capacity (BTU/h) 924172 1273369 1273355 1032300 1032309 924619 923556 924797 1346763 1346762 1346761 1346760 1346759 1346758 1346757 1401104 1044502 924009 924727 1273368 1273354 923472 923768 1346407 1346756 1346755 1346754 1346753 1032060 1032061 1032062 1038378 923736 924695 922238 924898 1483556 1483555 1443989 ARI # PRODUCT SPECIFICATIONS ARI PERFORMANCE RATINGS (CONT.) See Notes on Page 24. 23 24 www.goodmanmfg.com CHPF3642*6A*+TXV CHPF3642*6A*+TXV CHPF3642*6A+EEP+TXV CHPF3642C6A*+TXV CHPF3642C6A*+TXV CHPF3642C6B*+TXV CHPF3642C6B*+TXV CHPF3743C6A*+TXV CHPF3743C6A*+TXV CHPF3743C6A*+TXV CHPF3743C6A*+TXV CHPF3743C6A*+TXV CHPF3743C6A+EEP+TXV CSCF3642N6A*+TXV CSCF3642N6A*+TXV CSCF3642N6A*+TXV CSCF3642N6A*+TXV CSCF3642N6A*+TXV CSCF3642N6C*+TXV CSCF3642N6C*+TXV CSCF3642N6C*+TXV CSCF3642N6C*+TXV CSCF3642N6C*+TXV CT*F3636*6A*+TXV CT*F3636*6A*+TXV CT*F3636*6A*+TXV CT*F3642*6A*+EEP+TXV CT*F3642*6A*+TXV CT*F3642*6A*+TXV CT*F3642*6A*+TXV CT*F3642*6A*+TXV CT*F3642*6A*+TXV CT*F3642*6A*+TXV CT*F3642*6A*+TXV MBE1600**-1 MBR1600**-1 G*E80905C** G*E81155C** G*V80905C** G*V81155C** G*V950704C** G*E80905C** G*E81155C** G*V80905C** G*V81155C** G*V950704C** G*E80905C** G*E81155C** G*V80905C** G*V81155C** G*V950704C** MBE1200**-1 G*V950453B** G*V950704C** MBE1600**-1 MBR1600**-1 G*E80905C** G*E81155C** MBE1600**-1A MBR1600**-1A G*V80905C** G*V81155C** G*V950704C** G*V81155C** G*V950704C** Indoor Units Indoor Coil Furnace/Blower 22,500 22,500 22,500 22,500 22,500 22,500 22,500 22,500 22,500 22,500 22,500 22,500 22,500 22,500 22,500 22,500 22,500 22,500 22,500 22,500 22,500 22,500 22,500 22,500 22,500 22,500 22,200 22,500 22,500 22,500 22,500 22,500 22,500 22,500 14.50 14.50 14.00 15.00 14.00 14.50 14.50 15.00 14.00 14.50 14.50 14.50 14.00 14.50 14.50 14.50 14.50 14.50 14.50 14.50 14.50 14.50 14.50 15.00 15.00 15.00 14.00 15.00 14.00 14.50 14.50 14.50 14.50 14.50 12.20 12.20 12.00 12.50 12.00 12.20 12.20 12.50 12.00 12.20 12.20 12.20 12.00 12.20 12.20 12.20 12.20 12.20 12.20 12.20 12.20 12.20 12.20 13.00 12.00 12.00 12.00 12.50 12.00 12.20 12.20 12.20 12.20 12.00 Cooling Capacity (BTU/h) Sens. SEER¹ EER² 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,800 28,400 28,800 28,800 28,800 28,800 28,800 28,800 28,800 Total 26,600 26,600 26,600 26,600 26,600 26,600 26,600 26,600 26,600 26,600 26,600 26,600 26,600 26,600 26,600 26,600 26,600 26,600 26,600 26,600 26,600 26,600 26,600 26,600 26,600 26,600 26,300 26,600 26,600 26,600 26,600 26,600 26,600 26,600 22,300 22,300 22,300 22,300 22,300 22,300 22,300 22,300 22,300 22,300 22,300 22,300 22,300 22,300 22,300 22,300 22,300 22,300 22,300 22,300 22,300 22,300 22,300 22,300 22,300 22,300 22,100 22,300 22,300 22,300 22,300 22,300 22,300 22,300 TVA Ratings³ Total Sens. 29,000 29,000 28,000 29,000 29,000 29,000 29,000 29,000 29,000 29,000 29,000 29,000 28,000 29,000 29,000 29,000 29,000 29,000 29,000 29,000 29,000 29,000 29,000 28,000 28,000 28,000 28,800 29,000 29,000 29,000 29,000 29,000 29,000 28,000 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 18,000 Heating Capacity (BTU/h) High HSPF4 Low 921853 924206 1044496 1032304 1032307 1347591 1347593 1330363 1330364 1330428 1330429 1330430 1330362 1273356 1273370 921462 922494 924891 1296592 1296593 1296605 1296606 1296607 1450096 1450097 1450098 1450099 1450100 1450101 1450102 1450103 1450104 1450105 1450106 ARI # ¹ Seasonal Energy Ef ciency Ratio; Certi ed per ARI 210/240 @ 80°F/ 67°F/ 95°F ² Energy Ef ciency Ratio @ 80°F/ 67°F/ 95°F 4 HSPF = Heating Seasonal Performance Factor ³ TVA Rating: BTU/h @ 75°F/ 63°F - 95°F Notes: • Always check the S&R plate for electrical data on the unit being installed. • When matching the outdoor unit to the indoor unit, use the piston supplied with the outdoor unit or that speci ed on the piston kit chart supplied with the indoor unit. • EEP - Order from Service Dept. Part No. B13707-38 or new Solid State Board B13707-35S. Part No. B13707-38 is not interchangeable with B13707-35S. The Goodman Gas Furnace contains the EEP cooling time delay SSZ14 0301A* (cont.) Outdoor Unit PRODUCT SPECIFICATIONS ARI PERFORMANCE RATINGS (CONT.) SS-SSZ14 SS-SSZ14 SSZ14 0361A* Outdoor Unit www.goodmanmfg.com G*V90905D** G*V950704C** G*V950704C** G*V950905D** G*V950905D** G*V951155D** G*V951155D** G*E80905C** G*E81155C** G*V80905C** G*V81155C** G*V90905D** G*V950704C** G*V950905D** G*V951155D** CA*F060*4* CA*F060*4*+TXV CA*F060*4* CA*F060*4*+TXV CA*F060*4* CA*F060*4*+TXV CA*F4860*6A* CA*F4860*6A* CA*F4860*6A* CA*F4860*6A* CA*F4860*6A* CA*F4860*6A* CA*F4860*6A* CA*F4860*6A* CA*F4860*6A*+EEP G*V90905D** MBR1600**-1 CA*F060*4* CA*F060*4*+TXV MBE2000**-1 CA*F060*4*+TXV CA*F060*4* 35,000 MBE2000**-1 CA*F060*4* G*V81155C** 35,000 AT*F374316A*+TXV CA*F060*4*+TXV 35,000 AT*F374316A* G*V81155C** 36,000 ASPF426016B*+TXV G*V80905C** 36,000 ASPF426016B* CA*F060*4* 36,000 ASPF426016A*+TXV CA*F060*4*+TXV 36,000 ASPF426016A* G*V80905C** 35,000 ARUF374316A*+TXV CA*F060*4* 35,000 ARPF374316A*+TXV MBR1600**-1 35,000 AR*F374316B*+TXV CA*F060*4*+TXV 35,000 36,000 35,000 35,000 34,600 35,000 34,600 34,600 34,600 34,600 35,000 35,000 35,000 35,000 34,600 34,600 35,000 35,000 34,600 34,600 34,600 34,600 35,000 35,000 35,000 35,000 Total AR*F374316B* Furnace/Blower 25,900 25,200 25,200 24,900 25,200 24,900 24,900 24,900 24,900 25,200 25,200 25,200 25,200 24,900 24,900 25,200 25,200 24,900 24,900 24,900 24,900 25,200 25,200 25,200 25,200 25,200 25,200 25,900 25,900 25,900 25,900 25,200 25,200 25,200 25,200 25,200 Sens. 14.00 15.00 15.00 14.50 15.00 14.50 14.50 14.50 14.50 15.00 15.00 15.00 15.00 14.50 14.50 15.00 15.00 14.50 14.50 14.50 14.50 14.00 14.00 15.00 15.00 14.00 14.00 15.00 15.00 15.00 15.00 14.00 14.00 14.00 14.00 14.00 SEER¹ 12.00 12.50 12.50 12.20 12.50 12.20 12.20 12.20 12.20 12.50 12.50 12.50 12.50 12.20 12.20 12.50 12.50 12.20 12.20 12.20 12.20 12.00 12.00 12.50 12.50 12.00 12.00 13.00 13.00 13.00 13.00 12.00 12.00 12.00 12.00 12.00 EER² Cooling Capacity (BTU/h) AR*F374316A* Indoor Coil Indoor Units 33,300 32,400 32,400 32,000 32,400 32,000 32,000 32,000 32,000 32,400 32,400 32,400 32,400 32,000 32,000 32,400 32,400 32,000 32,000 32,000 32,000 32,400 32,400 32,400 32,400 32,400 32,400 33,300 33,300 33,300 33,300 32,400 32,400 32,400 32,400 32,400 Total 25,600 24,900 24,900 24,600 24,900 24,600 24,600 24,600 24,600 24,900 24,900 24,900 24,900 24,600 24,600 24,900 24,900 24,600 24,600 24,600 24,600 24,900 24,900 24,900 24,900 24,900 24,900 25,600 25,600 25,600 25,600 24,900 24,900 24,900 24,900 24,900 Sens. TVA Ratings³ 34,600 35,000 35,000 34,600 35,000 34,600 34,600 34,600 34,600 35,000 35,000 35,000 35,000 34,600 34,600 35,000 35,000 34,600 34,600 34,600 34,600 35,000 35,000 35,000 35,000 35,000 35,000 34,600 34,600 34,600 34,600 35,000 35,000 35,000 35,000 35,000 High 9.00 9.00 9.00 8.50 9.00 8.50 8.50 8.50 8.50 9.00 9.00 9.00 9.00 8.50 8.50 9.00 9.00 8.50 8.50 8.50 8.50 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 HSPF4 23,600 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 23,600 23,600 23,600 23,600 24,000 24,000 24,000 24,000 24,000 Low Heating Capacity (BTU/h) 3068869 3068880 3068879 3068878 3068877 3068876 3068875 3068874 3068873 923247 3068868 923813 3068867 923267 3068866 925012 3068865 922359 3068864 922054 3068863 922875 3069038 923042 3068862 1483558 3068861 1492629 3068859 1288549 3068858 1038362 1038363 1492649 3068853 3069671 ARI # PRODUCT SPECIFICATIONS ARI PERFORMANCE RATINGS (CONT.) See Notes on Page 24. 25 26 SSZ14 0361A* (cont.) Outdoor Unit www.goodmanmfg.com MBR1600**-1 A*V90704C** G*E80905C** G*E81155C** CA*F4961*6A*+TXV CA*F4961*6A*+TXV CA*F4961*6A*+TXV CA*F4961*6A*+TXV G*V81155C** MBR1600**-1 CA*F4961*6A* CA*F4961*6A*+TXV MBE2000**-1 CA*F4961*6A*+TXV G*V80905C** MBE2000**-1 CA*F4961*6A* CA*F4961*6A*+TXV MBE1600**-1 34,600 34,600 34,600 34,600 34,600 34,600 34,600 35,000 35,000 35,000 35,000 MBE1600**-1 CA*F4961*6A*+TXV 35,000 35,000 CA*F4961*6A* G*V951155D** CA*F4961*6A* 36,000 G*V950905D** CA*F4961*6A* 34,600 CA*F4961*6A*+EEP+TXV G*V950704C** CA*F4961*6A* 35,000 34,600 36,000 G*V90905D** 34,600 34,600 34,600 34,600 35,000 35,000 34,600 35,000 34,600 34,600 34,600 34,600 34,600 34,600 35,000 35,000 CA*F4961*6A*+EEP G*V81155C** CA*F4961*6A* G*V950905D** CA*F4860*6A*+TXV CA*F4961*6A* G*V950704C** CA*F4860*6A*+TXV G*V80905C** G*V90905D** CA*F4860*6A*+TXV CA*F4961*6A* G*V81155C** CA*F4860*6A*+TXV G*E81155C** G*V80905C** CA*F4860*6A*+TXV G*E80905C** G*E81155C** CA*F4860*6A*+TXV CA*F4961*6A* G*E80905C** CA*F4860*6A*+TXV CA*F4961*6A* MBR1600**-1 CA*F4860*6A*+TXV A*V90704C** MBR1600**-1 CA*F4860*6A* CA*F4961*6A* MBE2000**-1 CA*F4860*6A*+TXV G*V951155D** MBE2000**-1 CA*F4860*6A* CA*F4860*6A*+TXV MBE1600**-1 CA*F4860*6A*+TXV 35,000 36,000 35,000 MBE1600**-1 Total CA*F4860*6A* Furnace/Blower 24,900 24,900 24,900 24,900 24,900 24,900 24,900 25,200 25,200 25,200 25,200 25,900 25,900 25,200 25,200 24,900 25,200 24,900 24,900 24,900 24,900 24,900 25,200 25,200 24,900 25,200 24,900 24,900 24,900 24,900 24,900 24,900 25,200 25,200 25,200 25,200 25,900 Sens. 14.50 14.50 14.50 14.50 14.50 14.00 14.00 15.00 15.00 14.50 14.50 14.00 14.00 15.00 15.00 14.50 15.00 14.50 14.50 14.50 14.50 14.50 15.00 15.00 14.50 15.00 14.50 14.50 14.50 14.50 14.00 14.00 15.00 15.00 14.50 14.50 14.00 SEER¹ 12.20 12.20 12.20 12.20 12.20 12.00 12.00 12.50 12.50 12.20 12.20 12.00 12.00 12.50 12.50 12.20 12.50 12.20 12.20 12.20 12.20 12.20 12.50 12.50 12.20 12.50 12.20 12.20 12.20 12.20 12.00 12.00 12.50 12.50 12.20 12.20 12.00 EER² Cooling Capacity (BTU/h) CA*F4860*6A*+EEP+TXV Indoor Coil Indoor Units 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,400 32,400 32,400 32,400 33,300 33,300 32,400 32,400 32,000 32,400 32,000 32,000 32,000 32,000 32,000 32,400 32,400 32,000 32,400 32,000 32,000 32,000 32,000 32,000 32,000 32,400 32,400 32,400 32,400 33,300 Total 24,600 24,600 24,600 24,600 24,600 24,600 24,600 24,900 24,900 24,900 24,900 25,600 25,600 24,900 24,900 24,600 24,900 24,600 24,600 24,600 24,600 24,600 24,900 24,900 24,600 24,900 24,600 24,600 24,600 24,600 24,600 24,600 24,900 24,900 24,900 24,900 25,600 Sens. TVA Ratings³ 34,600 34,600 34,600 34,600 34,600 34,600 34,600 35,000 35,000 35,000 35,000 34,600 34,600 35,000 35,000 34,600 35,000 34,600 34,600 34,600 34,600 34,600 35,000 35,000 34,600 35,000 34,600 34,600 34,600 34,600 34,600 34,600 35,000 35,000 35,000 35,000 34,600 High 8.50 8.50 8.50 8.50 8.50 8.75 8.75 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 8.50 9.00 8.50 8.50 8.50 8.50 8.50 9.00 9.00 8.50 9.00 8.50 8.50 8.50 8.50 8.75 8.75 9.00 9.00 9.00 9.00 9.00 HSPF4 24,000 24,000 24,000 24,000 24,000 21,600 21,600 24,000 24,000 24,000 24,000 23,600 23,600 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 21,600 21,600 24,000 24,000 24,000 24,000 23,600 Low Heating Capacity (BTU/h) 1346770 1346769 1346768 1346767 1430186 1346766 3068884 1346765 3068883 1346764 3068882 1347226 3068881 3068893 3068892 3068891 3068890 3068889 3068888 3068887 3068886 3068885 922880 923055 923297 924170 922020 923048 1273371 1273357 924920 3068872 922498 3068871 921755 3068870 1038373 ARI # PRODUCT SPECIFICATIONS ARI PERFORMANCE RATINGS (CONT.) See Notes on Page 24. SS-SSZ14 SS-SSZ14 SSZ14 0361A* (cont.) Outdoor Unit MBE2000**-1A* G*V90905D** G*V951155D** G*V90905D** G*V951155D** CHPF4860D6A*+TXV CHPF4860D6A*+TXV CHPF4860D6A*+TXV CHPF4860D6C* CHPF4860D6C* G*V951155D** G*V951155D** G*V90905D** G*V951155D** G*V90905D** G*V951155D** G*V90905D** G*V951155D** G*E80905C** G*E81155C** G*V80905C** G*V81155C** G*V90905D** G*V950704C** G*V950905D** G*V951155D** MBE1600**-1 CSCF4860N6A* CSCF4860N6A*+TXV CSCF4860N6A*+TXV CSCF4860N6C* CSCF4860N6C* CSCF4860N6C*+TXV CSCF4860N6C*+TXV CT*F4860*6A* CT*F4860*6A* CT*F4860*6A* CT*F4860*6A* CT*F4860*6A* CT*F4860*6A* CT*F4860*6A* CT*F4860*6A* CT*F4860*6A* G*V90905D** CHPF4860D6C*+TXV G*V90905D** MBE2000**-1A* CHPF4860D6C*+TXV CSCF4860N6A* 34,600 MBE2000**-1A* CHPF4860D6C* CHPF4860D6C*+TXV 35,000 CHPF4860D6C*+EEP+TXV www.goodmanmfg.com 35,000 35,000 35,000 34,600 35,000 34,600 34,600 34,600 34,600 34,600 34,600 34,600 34,600 34,600 34,600 34,600 34,600 34,600 34,600 34,600 35,000 CHPF4860D6C*+EEP 34,600 34,600 34,600 34,600 34,600 34,600 34,600 MBE2000**-1A* G*V951155D** CHPF4860D6A* 34,600 CHPF4860D6A* G*V90905D** CHPF4860D6A* 35,000 35,000 35,000 G*V951155D** CA*F4961*6A*+TXV 35,000 G*V950905D** CA*F4961*6A*+TXV 35,000 34,600 CHPF4860D6A*+EEP+TXV G*V950704C** Total 25,200 25,200 25,200 24,900 25,200 24,900 24,900 24,900 24,900 24,900 24,900 24,900 24,900 24,900 24,900 24,900 24,900 24,900 24,900 24,900 24,900 25,200 25,200 24,900 24,900 24,900 24,900 24,900 24,900 25,200 25,200 24,900 24,900 25,200 25,200 24,900 25,200 Sens. 14.50 15.00 15.00 14.50 15.00 14.50 14.50 14.50 14.50 15.00 15.00 15.00 15.00 15.00 15.00 15.00 15.00 15.00 15.00 15.00 15.00 14.00 14.00 15.00 15.00 15.00 15.00 15.00 15.00 14.00 14.00 15.00 15.00 15.00 15.00 14.50 15.00 SEER¹ 12.20 12.50 12.50 12.20 12.50 12.20 12.20 12.20 12.20 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.00 12.00 12.50 12.50 12.50 12.50 12.50 12.50 12.00 12.00 12.50 12.50 12.50 12.50 12.20 12.50 EER² Cooling Capacity (BTU/h) CHPF4860D6A*+EEP G*V90905D** CA*F4961*6A*+TXV Furnace/Blower CA*F4961*6A*+TXV Indoor Coil Indoor Units 32,400 32,400 32,400 32,000 32,400 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,000 32,400 32,400 32,000 32,000 32,000 32,000 32,000 32,000 32,400 32,400 32,000 32,000 32,400 32,400 32,000 32,400 Total 24,900 24,900 24,900 24,600 24,900 24,600 24,600 24,600 24,600 24,600 24,600 24,600 24,600 24,600 24,600 24,600 24,600 24,600 24,600 24,600 24,600 24,900 24,900 24,600 24,600 24,600 24,600 24,600 24,600 24,900 24,900 24,600 24,600 24,900 24,900 24,600 24,900 Sens. TVA Ratings³ 35,000 35,000 35,000 34,600 35,000 34,600 34,600 34,600 34,600 34,600 34,600 34,600 34,600 34,600 34,600 34,600 34,600 34,600 34,600 34,600 34,600 34,600 34,600 34,600 34,600 34,600 34,600 34,600 34,600 34,600 34,600 34,600 34,600 35,000 35,000 34,600 35,000 High 9.00 9.00 9.00 8.50 9.00 8.50 8.50 8.50 8.50 8.75 8.75 8.75 8.75 8.75 8.75 8.75 8.75 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 8.50 9.00 HSPF4 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 21,000 21,000 21,000 21,000 21,000 21,000 21,000 21,000 21,000 21,000 21,000 21,000 21,000 21,000 21,000 21,000 21,000 21,000 21,000 21,000 21,000 21,000 21,000 21,000 24,000 24,000 24,000 24,000 Low Heating Capacity (BTU/h) 3068906 3068916 3068915 3068914 3068913 3068912 3068911 3068910 3068909 1296664 1296663 3068905 3068904 1128631 1128630 3068903 3068902 1330368 1330367 1330366 3068899 1330365 3068898 3068901 3068900 1128629 1128628 1145315 3068895 1128632 3068894 3068897 3068896 1346774 1346773 1346772 1346771 ARI # PRODUCT SPECIFICATIONS ARI PERFORMANCE RATINGS (CONT.) See Notes on Page 24. 27 28 SSZ14 0421A* SSZ14 0361A* (cont.) Outdoor Unit MBE2000**-1 MBE2000**-1 MBR1600**-1 MBR1600**-1 G*E80905C** G*E81155C** G*V80905C** G*V81155C** G*V90905D** G*V950704C** G*V950905D** G*V951155D** CT*F4860*6A*+TXV CT*F4860*6A* CT*F4860*6A*+TXV CT*F4860*6A*+TXV CT*F4860*6A*+TXV CT*F4860*6A*+TXV CT*F4860*6A*+TXV CT*F4860*6A*+TXV CT*F4860*6A*+TXV CT*F4860*6A*+TXV CT*F4860*6A*+TXV www.goodmanmfg.com 41,000 41,000 40,000 40,000 40,000 40,000 40,000 41,000 41,000 41,000 41,000 40,000 40,000 40,000 MBE2000**-1 MBR2000**-1 G*V950905D** G*V951155D** G*V950905D** AEPF426016C* AEPF426016C*+TXV AR*F374316A* AR*F374316B* AR*F374316B*+TXV ARPF374316A*+TXV ARUF374316A*+TXV ASPF426016A* ASPF426016A*+TXV ASPF426016B* ASPF426016B*+TXV AT*F374316A* AT*F374316A*+TXV CA*F060*4*+TXV CA*F060*4*+TXV CA*F060*4*+TXV CA*F060*4*+TXV CA*F4860*6A* CA*F4860*6A*+EEP G*V951155D** 41,000 AEPF426016B*+TXV CA*F4860*6A* 41,000 AEPF426016B* 41,000 40,000 40,000 40,000 40,000 40,000 41,000 41,000 35,000 35,000 34,600 35,000 34,600 34,600 34,600 34,600 34,600 34,600 35,000 35,000 35,000 Total 31,600 30,800 30,800 30,800 30,800 30,800 30,800 30,800 30,800 31,600 31,600 31,600 31,600 30,800 30,800 30,800 30,800 30,800 31,600 31,600 31,600 31,600 31,600 31,600 25,200 25,200 24,900 25,200 24,900 24,900 24,900 24,900 24,900 24,900 25,200 25,200 25,200 Sens. 14.00 15.00 15.00 15.00 15.00 14.00 15.00 14.00 14.00 15.00 15.00 15.00 15.00 14.00 14.00 14.00 14.00 14.00 15.00 15.00 15.00 15.00 15.00 15.00 15.00 15.00 14.50 15.00 14.50 14.50 14.50 14.50 14.00 14.00 15.00 15.00 14.50 SEER¹ 12.00 12.50 12.50 12.50 12.50 12.00 12.50 12.00 12.00 13.00 13.00 13.00 13.00 12.00 12.00 12.00 12.00 12.00 13.00 13.00 13.00 13.00 13.00 13.00 12.50 12.50 12.20 12.50 12.20 12.20 12.20 12.20 12.00 12.00 12.50 12.50 12.20 EER² Cooling Capacity (BTU/h) AEPF426016A*+TXV AEPF426016A* MBE1600**-1 CT*F4860*6A* Furnace/Blower CT*F4860*6A*+TXV Indoor Coil Indoor Units 37,900 37,000 37,000 37,000 37,000 37,000 37,000 37,000 37,000 37,900 37,900 37,900 37,900 37,000 37,000 37,000 37,000 37,000 37,900 37,900 37,900 37,900 37,900 37,900 32,400 32,400 32,000 32,400 32,000 32,000 32,000 32,000 32,000 32,000 32,400 32,400 32,400 Total 31,100 30,300 30,300 30,300 30,300 30,300 30,300 30,300 30,300 31,100 31,100 31,100 31,100 30,300 30,300 30,300 30,300 30,300 31,100 31,100 31,100 31,100 31,100 31,100 24,900 24,900 24,600 24,900 24,600 24,600 24,600 24,600 24,600 24,600 24,900 24,900 24,900 Sens. TVA Ratings³ 41,000 41,000 41,000 41,000 41,000 41,000 41,000 40,000 40,000 40,000 40,000 40,000 40,000 40,000 40,000 40,000 40,000 40,000 40,000 40,000 40,000 40,000 40,000 40,000 35,000 35,000 34,600 35,000 34,600 34,600 34,600 34,600 34,600 34,600 35,000 35,000 35,000 High 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 8.50 9.00 8.50 8.50 8.50 8.50 8.75 8.75 9.00 9.00 9.00 HSPF4 27,400 25,000 25,000 25,000 25,000 25,000 25,000 25,000 25,000 27,400 27,400 27,400 27,400 25,000 25,000 25,000 25,000 25,000 27,400 27,400 27,400 27,400 27,400 27,400 24,000 24,000 24,000 24,000 24,000 24,000 24,000 24,000 21,600 21,600 24,000 24,000 24,000 Low Heating Capacity (BTU/h) 3068930 3068934 3068933 923311 924087 924636 923006 1483559 3068925 1492631 3068924 1288550 3068923 1038360 1038361 1492650 3068920 3069672 1492630 3068919 1277859 3068918 1044183 3068917 1450117 1450116 1450115 1450114 1450113 1450112 1450111 1450110 1450109 3068908 1450108 3068907 1450107 ARI # PRODUCT SPECIFICATIONS ARI PERFORMANCE RATINGS (CONT.) See Notes on Page 30. SS-SSZ14 SS-SSZ14 SSZ14 0421A* (cont.) Outdoor Unit MBE2000**-1 MBR2000**-1 MBR2000**-1 G*V950905D** G*V951155D** G*V950905D** G*V951155D** CA*F4860*6A*+TXV CA*F4860*6A* CA*F4860*6A*+TXV CA*F4860*6A*+TXV CA*F4860*6A*+TXV CA*F4961*6A* CA*F4961*6A* www.goodmanmfg.com MBE2000**-1 MBE2000**-1 G*V950905D** G*V951155D** CHPF4860*6A* CHPF4860*6A*+TXV CHPF4860*6A*+TXV CHPF4860*6A*+TXV 40,000 40,000 40,000 40,000 40,000 40,000 G*V951155D** CHPF4860D6C* CHPF4860D6C* MBE2000**-1A* G*V950905D** G*V951155D** GMV950905D** GMV951155D** CHPF4860D6C*+TXV CHPF4860D6C*+TXV CHPF4860D6C*+TXV CSCF4860N6A* CSCF4860N6A* GMV950905D** 40,000 MBE2000**-1A* CHPF4860D6C* CSCF4860N6A*+TXV 41,000 CHPF4860D6C*+EEP+TXV 40,000 40,000 40,000 40,000 40,000 40,000 41,000 CHPF4860D6C*+EEP 40,000 41,000 40,000 G*V950905D** CHPF4860D6A*+EEP+TXV 41,000 G*V951155D** CHPF4860*6A* 40,000 40,000 40,000 40,000 40,000 40,000 CHPF4860D6A*+EEP G*V950905D** CHPF4860*6A* MBR2000**-1 CHPF060D4*+TXV G*V951155D** G*V951155D** CA*F4961*6A*+TXV CHPF060D4*+TXV G*V950905D** MBR2000**-1 CA*F4961*6A* CA*F4961*6A*+TXV MBE2000**-1 CA*F4961*6A*+TXV MBR2000**-1 40,000 MBE2000**-1 CA*F4961*6A* CA*F4961*6A*+TXV 41,000 CA*F4961*6A*+EEP+TXV 40,000 41,000 CA*F4961*6A*+EEP 40,000 40,000 40,000 40,000 40,000 40,000 40,000 41,000 40,000 MBE2000**-1 Total CA*F4860*6A* Furnace/Blower 30,800 30,800 30,800 30,800 30,800 30,800 30,800 31,600 31,600 30,800 30,800 31,600 31,600 30,800 30,800 30,800 30,800 30,800 30,800 30,800 30,800 30,800 30,800 30,800 30,800 30,800 30,800 31,600 31,600 30,800 30,800 30,800 30,800 30,800 30,800 30,800 30,800 31,600 Sens. 15.00 15.00 15.00 15.00 15.00 15.00 15.00 14.00 14.00 15.00 15.00 14.00 14.00 15.00 15.00 15.00 15.00 15.00 15.00 15.00 14.00 15.00 15.00 14.00 14.00 15.00 15.00 14.00 14.00 15.00 15.00 15.00 15.00 14.00 14.00 15.00 15.00 14.00 SEER¹ 12.50 12.50 12.50 12.50 12.50 12.00 12.00 12.00 12.00 12.50 12.50 12.00 12.00 12.50 12.50 12.00 12.00 12.50 12.50 12.50 12.50 12.50 12.50 12.00 12.00 12.50 12.50 12.00 12.00 12.50 12.50 12.50 12.50 12.00 12.00 12.50 12.50 12.00 EER² Cooling Capacity (BTU/h) CA*F4860*6A*+EEP+TXV Indoor Coil Indoor Units 37,000 37,000 37,000 37,000 37,000 37,000 37,000 37,900 37,900 37,000 37,000 37,900 37,900 37,000 37,000 37,000 37,000 37,000 37,000 37,000 37,000 37,000 37,000 37,000 37,000 37,000 37,000 37,900 37,900 37,000 37,000 37,000 37,000 37,000 37,000 37,000 37,000 37,900 Total 30,300 30,300 30,300 30,300 30,300 30,300 30,300 31,100 31,100 30,300 30,300 31,100 31,100 30,300 30,300 30,300 30,300 30,300 30,300 30,300 30,300 30,300 30,300 30,300 30,300 30,300 30,300 31,100 31,100 30,300 30,300 30,300 30,300 30,300 30,300 30,300 30,300 31,100 Sens. TVA Ratings³ 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 High 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 HSPF4 25,000 25,000 25,000 25,000 25,000 25,000 25,000 27,400 27,400 25,000 25,000 27,400 27,400 25,000 25,000 25,000 25,000 25,000 25,000 25,000 25,000 25,000 25,000 25,000 25,000 25,000 25,000 27,400 27,400 25,000 25,000 25,000 25,000 25,000 25,000 25,000 25,000 27,400 Low Heating Capacity (BTU/h) 924332 3068950 3068949 1330433 1330432 1330431 3068946 1330369 3068945 3068948 3068947 1046127 3068944 923603 922130 924731 3068941 3068943 3068942 923733 924493 1346777 1346776 1347181 3068937 1346775 3068936 1347227 3068935 3068939 3068938 921743 923656 921675 3068932 924196 3068931 1038372 ARI # PRODUCT SPECIFICATIONS ARI PERFORMANCE RATINGS (CONT.) See Notes on Page 30. 29 30 www.goodmanmfg.com GMV951155D** GMV950905D** GMV951155D** G*V950905D** G*V951155D** MBE2000**-1 MBE2000**-1 MBR2000**-1 MBR2000**-1 G*V950905D** G*V951155D** CSCF4860N6C* CSCF4860N6C*+TXV CSCF4860N6C*+TXV CT*F4860*6A* CT*F4860*6A* CT*F4860*6A* CT*F4860*6A*+TXV CT*F4860*6A* CT*F4860*6A*+TXV CT*F4860*6A*+TXV CT*F4860*6A*+TXV 47,000 47,000 47,000 47,000 46,000 G*V950905D** MBE2000**-1 ASPF426016B* ASPF426016B*+TXV AT*F374316A* AT*F374316A*+TXV CA*F060*4* CA*F060*4*+TXV 46,000 47,000 47,000 AR*F374316B*+TXV ASPF426016A*+TXV 47,000 AR*F374316B* 47,000 47,000 AR*F374316A* ASPF426016A* 47,000 AEPF426016C*+TXV 47,000 47,000 AEPF426016C* ARUF374316A*+TXV 47,000 AEPF426016B*+TXV 47,000 47,000 AEPF426016B* ARPF374316A*+TXV 47,000 47,000 40,000 40,000 40,000 40,000 40,000 40,000 40,000 40,000 40,000 40,000 40,000 40,000 40,000 Total 35,000 35,000 35,700 35,700 35,700 35,700 35,700 35,700 35,700 35,700 35,700 35,700 35,700 35,700 35,700 35,700 35,700 35,700 35,700 30,800 30,800 30,800 30,800 30,800 30,800 30,800 30,800 30,800 30,800 30,800 30,800 30,800 Sens. 15.00 14.50 14.00 14.00 15.00 15.00 15.00 15.00 14.00 14.00 14.00 14.00 14.00 15.00 15.00 15.00 15.00 15.00 15.00 15.00 15.00 14.00 14.00 15.00 15.00 15.00 15.00 15.00 15.00 15.00 15.00 15.00 SEER¹ 12.50 12.00 12.00 12.00 13.00 13.00 13.00 13.00 12.00 12.00 12.00 12.00 12.00 13.00 13.00 13.00 13.00 13.00 13.00 12.50 12.50 12.00 12.00 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 EER² Cooling Capacity (BTU/h) AEPF426016A*+TXV AEPF426016A* GMV951155D** GMV950905D** CSCF4860N6C* Furnace/Blower CSCF4860N6A*+TXV Indoor Coil Indoor Units 42,600 42,600 43,500 43,500 43,500 43,500 43,500 43,500 43,500 43,500 43,500 43,500 43,500 43,500 43,500 43,500 43,500 43,500 43,500 37,000 37,000 37,000 37,000 37,000 37,000 37,000 37,000 37,000 37,000 37,000 37,000 37,000 Total 34,500 34,500 35,200 35,200 35,200 35,200 35,200 35,200 35,200 35,200 35,200 35,200 35,200 35,200 35,200 35,200 35,200 35,200 35,200 30,300 30,300 30,300 30,300 30,300 30,300 30,300 30,300 30,300 30,300 30,300 30,300 30,300 Sens. TVA Ratings³ 46,000 47,000 47,000 47,000 47,000 47,000 47,000 47,000 47,000 47,000 47,000 47,000 47,000 47,000 47,000 47,000 47,000 47,000 47,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 41,000 High 9.00 8.50 8.50 8.50 8.75 8.75 8.75 8.75 8.50 8.50 8.50 8.50 8.50 8.75 8.75 8.75 8.75 8.75 8.75 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 HSPF4 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 25,000 25,000 25,000 25,000 25,000 25,000 25,000 25,000 25,000 25,000 25,000 25,000 25,000 Low Heating Capacity (BTU/h) 923100 921702 1483560 3068965 1492633 3068964 1288551 3068963 1038359 1038357 1492651 3068960 3069673 1492632 3068959 1277860 3068958 1044184 3068957 1450121 1450120 1450119 3068954 1450118 3068953 3068956 3068955 1296666 1296665 3068952 3068951 923849 ARI # ¹ Seasonal Energy Ef ciency Ratio; Certi ed per ARI 210/240 @ 80°F/ 67°F/ 95°F ² Energy Ef ciency Ratio @ 80°F/ 67°F/ 95°F 4 HSPF = Heating Seasonal Performance Factor ³ TVA Rating: BTU/h @ 75°F/ 63°F - 95°F Notes: • Always check the S&R plate for electrical data on the unit being installed. • When matching the outdoor unit to the indoor unit, use the piston supplied with the outdoor unit or that speci ed on the piston kit chart supplied with the indoor unit. • EEP - Order from Service Dept. Part No. B13707-38 or new Solid State Board B13707-35S. Part No. B13707-38 is not interchangeable with B13707-35S. The Goodman Gas Furnace contains the EEP cooling time delay SSZ14 0481A* SSZ14 0421A* (cont.) Outdoor Unit PRODUCT SPECIFICATIONS ARI PERFORMANCE RATINGS (CONT.) SS-SSZ14 SS-SSZ14 SSZ14 0481A* (cont.) Outdoor Unit G*V81155C** G*V951155D** G*V950905D** CA*F4860*6A* CA*F4860*6A* CA*F4860*6A* 46,000 46,000 45,000 46,000 46,000 G*V951155D** G*V81155C** CA*F4860*6A*+TXV CA*F4860*6A*+TXV CA*F4961*6A* 46,000 46,000 MBE2000**-1 MBE2000**-1 MBR2000**-1 MBR2000**-1 G*V81155C** G*V950905D** G*V951155D** G*V950905D** G*V950905D** G*V951155D** CA*F4961*6A*+EEP+TXV CA*F4961*6A* CA*F4961*6A*+TXV CA*F4961*6A* CA*F4961*6A*+TXV CA*F4961*6A*+TXV www.goodmanmfg.com CA*F4961*6A*+TXV CA*F4961*6A*+TXV CHPF060D4* CHPF060D4*+TXV CHPF4860D6A* 46,000 MBR2000**-1 MBR2000**-1 G*V951155D** G*V951155D** CHPF4860D6A* CHPF4860D6A*+TXV CHPF4860D6A*+TXV CHPF4860D6C* 47,000 47,000 46,000 CHPF4860D6C*+EEP+TXV CHPF4860D6C* 46,000 46,000 CHPF4860D6C*+EEP MBR2000**-1A* 47,000 CHPF4860D6A*+EEP+TXV 46,000 47,000 CHPF4860D6A*+EEP 46,000 46,000 46,000 46,000 46,000 45,000 46,000 46,000 46,000 46,000 46,000 46,000 45,000 46,000 45,000 46,000 46,000 CA*F4961*6A*+EEP G*V951155D** G*V81155C** CA*F4860*6A*+TXV CA*F4961*6A* MBR2000**-1 CA*F4860*6A* G*V950905D** MBR2000**-1 CA*F4860*6A*+TXV CA*F4961*6A* MBE2000**-1 CA*F4860*6A* 46,000 46,000 46,000 MBE2000**-1 CA*F4860*6A*+EEP+TXV 46,000 G*V951155D** Total 35,000 35,700 35,700 35,000 35,000 35,000 35,000 35,700 35,700 35,000 35,000 35,000 35,000 35,000 34,200 35,000 35,000 35,000 35,000 35,000 35,000 35,000 35,000 34,200 35,000 34,200 35,000 35,000 35,000 35,000 35,000 35,000 35,000 35,000 34,200 35,000 35,000 Sens. 14.50 14.00 14.00 14.50 14.50 14.50 14.50 14.00 14.00 14.50 14.50 14.50 14.50 14.50 14.50 14.00 14.00 15.00 15.00 14.00 14.00 14.50 14.50 14.50 14.50 14.50 14.00 14.00 15.00 15.00 14.00 14.00 14.50 14.50 14.50 14.50 14.00 SEER¹ 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.50 12.50 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.50 12.50 12.00 12.00 12.00 12.00 12.00 12.00 12.00 EER² Cooling Capacity (BTU/h) CA*F4860*6A*+EEP MBR2000**-1 CA*F060*4*+TXV Furnace/Blower CA*F060*4*+TXV Indoor Coil Indoor Units 42,600 43,500 43,500 42,600 42,600 42,600 42,600 43,500 43,500 42,600 42,600 42,600 42,600 42,600 41,600 42,600 42,600 42,600 42,600 42,600 42,600 42,600 42,600 41,600 42,600 41,600 42,600 42,600 42,600 42,600 42,600 42,600 42,600 42,600 41,600 42,600 42,600 Total 34,500 35,200 35,200 34,500 34,500 34,500 34,500 35,200 35,200 34,500 34,500 34,500 34,500 34,500 33,700 34,500 34,500 34,500 34,500 34,500 34,500 34,500 34,500 33,700 34,500 33,700 34,500 34,500 34,500 34,500 34,500 34,500 34,500 34,500 33,700 34,500 34,500 Sens. TVA Ratings³ 47,000 46,000 46,000 47,000 47,000 47,000 47,000 46,000 46,000 47,000 47,000 47,000 47,000 47,000 47,000 47,000 47,000 46,000 46,000 47,000 47,000 47,000 47,000 47,000 47,000 47,000 47,000 47,000 46,000 46,000 47,000 47,000 47,000 47,000 47,000 47,000 47,000 High 8.50 9.00 9.00 8.50 8.50 8.50 8.50 9.00 9.00 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 9.00 9.00 8.75 8.75 8.50 8.50 8.50 8.50 8.50 8.50 8.50 9.00 9.00 8.75 8.75 8.50 8.50 8.50 8.50 8.50 HSPF4 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 Low Heating Capacity (BTU/h) 3068984 1330370 3068983 3068985 921639 922859 3068981 1046128 3068980 3068982 1032306 3069040 1346780 1347183 1346779 1347182 3068976 1346778 3068975 1347228 3068974 3068979 3068978 3068977 924051 1293993 923108 3068971 924882 3068970 1038370 3068969 921973 3068973 3068972 921392 922384 ARI # PRODUCT SPECIFICATIONS ARI PERFORMANCE RATINGS (CONT.) See Notes on Page 30. 31 32 SSZ14 0601A* SSZ14 0481A* (cont.) Outdoor Unit www.goodmanmfg.com 57,000 ASPF426016A* 57,000 57,000 ARUF486061A*+TXV ASPF426016B* 57,000 ARUF374316A*+TXV 57,000 57,000 ARPF374316A*+TXV ASPF426016A*+TXV 57,000 AR*F496116A*+TXV 57,000 AR*F374316B* 57,000 57,000 AR*F374316A* AR*F496116A* 57,000 AEPF426016C*+TXV 57,000 57,000 AEPF426016C* AR*F374316B*+TXV 57,000 AEPF426016B*+TXV 46,000 57,000 G*V951155D** CT*F4860*6A*+TXV 46,000 AEPF426016B* G*V950905D** CT*F4860*6A*+TXV 45,000 57,000 G*V81155C** CT*F4860*6A*+TXV 46,000 AEPF426016A*+TXV MBR2000**-1 CT*F4860*6A*+TXV 46,000 57,000 MBR2000**-1 CT*F4860*6A* 46,000 46,000 46,000 46,000 45,000 46,000 46,000 46,000 46,000 46,000 46,000 46,000 46,000 46,000 46,000 Total 42,200 42,200 42,200 42,200 42,200 42,200 42,200 42,200 42,200 42,200 42,200 42,200 42,200 42,200 42,200 42,200 42,200 35,000 35,000 34,200 35,000 35,000 35,000 35,000 35,000 35,000 34,200 35,000 35,000 35,000 35,000 35,000 35,000 35,000 35,000 35,000 35,000 Sens. 14.50 14.50 14.50 13.50 13.50 13.50 13.50 13.50 13.50 13.50 13.50 14.50 14.50 14.50 14.50 14.50 14.50 14.50 14.50 14.50 14.00 14.00 15.00 15.00 14.50 14.50 14.50 14.50 14.50 14.50 14.50 14.50 14.50 14.50 14.50 14.50 14.50 SEER¹ 12.00 12.00 12.00 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.50 12.50 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 EER² Cooling Capacity (BTU/h) AEPF426016A* MBE2000**-1 MBE2000**-1 CT*F4860*6A*+TXV CT*F4860*6A* G*V950905D** CSCF4860N6C*+TXV G*V951155D** G*V951155D** CSCF4860N6C* G*V950905D** G*V950905D** CSCF4860N6C* CT*F4860*6A* G*V951155D** CSCF4860N6A*+TXV CT*F4860*6A* G*V950905D** CSCF4860N6A*+TXV G*V951155D** G*V951155D** CSCF4860N6A* G*V81155C** G*V950905D** CSCF4860N6A* CT*F4860*6A* G*V951155D** CSCF4860N6C*+TXV MBR2000**-1A* CHPF4860D6C*+TXV Furnace/Blower CHPF4860D6C*+TXV Indoor Coil Indoor Units 52,700 52,700 52,700 52,700 52,700 52,700 52,700 52,700 52,700 52,700 52,700 52,700 52,700 52,700 52,700 52,700 52,700 42,600 42,600 41,600 42,600 42,600 42,600 42,600 42,600 42,600 41,600 42,600 42,600 42,600 42,600 42,600 42,600 42,600 42,600 42,600 42,600 Total 41,600 41,600 41,600 41,600 41,600 41,600 41,600 41,600 41,600 41,600 41,600 41,600 41,600 41,600 41,600 41,600 41,600 34,500 34,500 33,700 34,500 34,500 34,500 34,500 34,500 34,500 33,700 34,500 34,500 34,500 34,500 34,500 34,500 34,500 34,500 34,500 34,500 Sens. TVA Ratings³ 59,000 59,000 59,000 57,000 57,000 57,000 57,000 57,000 57,000 57,000 57,000 59,000 59,000 59,000 59,000 59,000 59,000 47,000 47,000 47,000 47,000 47,000 46,000 46,000 47,000 47,000 47,000 47,000 47,000 47,000 47,000 47,000 47,000 47,000 47,000 47,000 47,000 High 8.75 8.75 8.75 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.75 8.75 8.75 8.75 8.75 8.75 8.50 8.50 8.50 8.50 8.50 9.00 9.00 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 HSPF4 39,000 39,000 39,000 33,000 33,000 33,000 33,000 33,000 33,000 33,000 33,000 39,000 39,000 39,000 39,000 39,000 39,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 Low Heating Capacity (BTU/h) 3069003 1288552 3069002 1328892 1038358 1038356 1492635 3068999 3018432 3068998 3069674 1492634 3068997 1277861 3068996 1044185 3068995 1450126 1450122 1450125 1450124 3068991 1450123 3068990 3068994 3068993 3068992 1296668 1296667 3068989 3068988 922614 922245 3068987 3068986 1330435 1330434 ARI # PRODUCT SPECIFICATIONS ARI PERFORMANCE RATINGS (CONT.) See Notes on Page 30. SS-SSZ14 SS-SSZ14 SSZ14 0601A* (cont.) Outdoor Unit Indoor Units G*V951155D** G*V950905D** G*V951155D** CA*F060*4*+TXV CA*F4860*6A* CA*F4860*6A* www.goodmanmfg.com MBE2000**-1 MBR2000**-1 MBR2000**-1 G*V950905D** G*V951155D** MBR2000**-1 G*V950905D** G*V951155D** MBE2000**-1 MBE2000**-1 G*V950905D** G*V951155D** CA*F4961*6A*+TXV CA*F4961*6A* CA*F4961*6A*+TXV CA*F4961*6A*+TXV CA*F4961*6A*+TXV CHPF060D4*+TXV CHPF060D4*+TXV CHPF060D4*+TXV CHPF4860*6A* CHPF4860*6A*+TXV CHPF4860D6A* CHPF4860D6A* 56,500 56,500 56,500 56,500 56,500 56,500 56,500 56,500 56,500 56,500 56,500 56,500 56,500 56,500 MBE2000**-1 G*V951155D** CA*F4961*6A* 56,500 56,500 CA*F4961*6A* G*V950905D** CA*F4961*6A* 57,000 G*V951155D** CA*F4860*6A*+TXV 56,500 56,500 57,000 G*V950905D** CA*F4860*6A*+TXV CA*F4961*6A*+EEP+TXV MBR2000**-1 CA*F4860*6A*+TXV 56,500 CA*F4961*6A*+EEP MBR2000**-1 CA*F4860*6A* 56,500 56,500 CA*F4860*6A* MBE2000**-1 57,000 CA*F4860*6A*+EEP+TXV CA*F4860*6A*+TXV 57,000 56,500 56,500 56,500 CA*F4860*6A*+EEP MBE2000**-1 MBR2000**-1 CA*F060*4*+TXV 56,500 57,000 56,500 MBE2000**-1 57,000 AT*F486016A* CA*F060*4*+TXV 57,000 AT*F486016A*+TXV 57,000 AT*F374316A*+TXV 41,800 41,800 41,800 41,800 41,800 41,800 41,800 41,800 41,800 41,800 41,800 41,800 41,800 42,200 42,200 41,800 41,800 41,800 41,800 41,800 41,800 41,800 41,800 42,200 42,200 41,800 41,800 41,800 41,800 41,800 42,200 42,200 42,200 42,200 42,200 Sens. 14.00 14.00 15.00 15.00 14.00 14.00 15.00 14.00 14.00 14.00 14.00 15.00 15.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 15.00 15.00 14.00 14.00 14.00 14.00 14.00 14.00 15.00 13.50 13.50 13.50 13.50 14.50 SEER¹ 11.50 11.50 12.50 12.50 11.50 11.50 12.50 12.00 12.00 12.00 12.00 12.50 12.50 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.50 12.50 12.00 12.00 12.00 12.00 12.00 12.00 12.50 11.50 11.50 11.50 11.50 12.00 EER² Cooling Capacity (BTU/h) AT*F374316A* Total 57,000 Furnace/Blower ASPF426016B*+TXV Indoor Coil 52,300 52,300 52,300 52,300 52,300 52,300 52,300 52,300 52,300 52,300 52,300 52,300 52,300 52,700 52,700 52,300 52,300 52,300 52,300 52,300 52,300 52,300 52,300 52,700 52,700 52,300 52,300 52,300 52,300 52,300 52,700 52,700 52,700 52,700 52,700 41,300 41,300 41,300 41,300 41,300 41,300 41,300 41,300 41,300 41,300 41,300 41,300 41,300 41,600 41,600 41,300 41,300 41,300 41,300 41,300 41,300 41,300 41,300 41,600 41,600 41,300 41,300 41,300 41,300 41,300 41,600 41,600 41,600 41,600 41,600 Sens. TVA Ratings³ Total 57,000 57,000 57,000 57,000 57,000 57,000 57,000 57,000 57,000 57,000 57,000 57,000 57,000 58,000 58,000 57,000 57,000 57,000 57,000 57,000 57,000 57,000 57,000 58,000 58,000 57,000 57,000 57,000 57,000 57,000 57,000 57,000 57,000 57,000 59,000 High 8.50 8.50 9.00 9.00 8.50 8.50 9.00 8.50 8.50 8.50 8.50 9.00 9.00 8.75 8.75 8.50 8.50 8.50 8.50 8.50 8.50 9.00 9.00 8.75 8.75 8.50 8.50 8.50 8.50 9.00 8.50 8.50 8.50 8.50 8.75 HSPF4 33,000 33,000 33,000 33,000 33,000 33,000 33,000 33,000 33,000 33,000 33,000 33,000 33,000 39,500 39,500 33,000 33,000 33,000 33,000 33,000 33,000 33,000 33,000 39,500 39,500 33,000 33,000 33,000 33,000 33,000 33,000 33,000 33,000 33,000 39,000 Low Heating Capacity (BTU/h) 3069024 3069023 1031763 3069020 921532 923987 923520 1346783 1346782 1347184 3069016 1346781 3069015 1347229 3069014 3069018 3069017 1031676 924841 924733 3069011 923828 3069010 1038371 3069009 3069013 3069012 921993 924990 924942 1483562 3069005 1483561 3069004 1492636 ARI # PRODUCT SPECIFICATIONS ARI PERFORMANCE RATINGS (CONT.) See Notes on Page 30. 33 34 SSZ14 0601A* (cont.) Outdoor Unit Indoor Units Total MBR2000**-1 G*V950905D** G*V951155D** G*V950905D** G*V951155D** CHPF4860D6A* CHPF4860D6A*+TXV CHPF4860D6A*+TXV CHPF4860D6A*+TXV CHPF4860D6C* CHPF4860D6C* www.goodmanmfg.com MBE2000**-1 MBE2000**-1 MBR2000**-1 MBR2000**-1 G*V950905D** G*V951155D** CT*F4860*6A*+TXV CT*F4860*6A* CT*F4860*6A*+TXV CT*F4860*6A*+TXV CT*F4860*6A*+TXV CSCF4860N6C*+TXV G*V951155D** G*V90905D** CSCF4860N6C* CT*F4860*6A* G*V951155D** CSCF4860N6C* CT*F4860*6A* G*V90905D** CSCF4860N6A*+TXV G*V951155D** G*V951155D** CSCF4860N6A*+TXV G*V950905D** G*V90905D** CSCF4860N6A* CT*F4860*6A* G*V951155D** CSCF4860N6A* CSCF4860N6C*+TXV G*V951155D** G*V90905D** CHPF4860D6C*+TXV G*V950905D** CHPF4860D6C*+TXV CHPF4860D6C* MBR2000**-1A* MBR2000**-1A* CHPF4860D6C*+TXV CHPF4860D6C*+TXV MBE2000**-1A* CHPF4860D6C* 56,500 56,500 56,500 56,500 56,500 56,500 56,500 56,500 56,500 56,500 56,500 56,500 56,500 56,500 56,500 56,500 56,500 56,500 57,000 57,000 56,500 57,000 56,500 MBE2000**-1A* CHPF4860D6C*+EEP+TXV 57,000 CHPF4860D6C*+EEP 56,500 56,500 56,500 56,500 57,000 57,000 57,000 MBR2000**-1 CHPF4860D6A*+EEP+TXV 41,800 41,800 41,800 41,800 41,800 41,800 41,800 41,800 41,800 41,800 41,800 41,800 41,800 41,800 41,800 41,800 41,800 41,800 42,200 42,200 41,800 41,800 42,200 42,200 41,800 41,800 41,800 41,800 42,200 42,200 42,200 42,200 Sens. 14.00 14.00 14.00 14.00 15.00 15.00 14.00 14.00 13.50 14.00 13.50 14.00 13.50 14.00 13.50 14.00 14.00 14.00 14.00 14.00 15.00 15.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 SEER¹ 12.00 12.00 12.00 12.00 12.50 12.50 12.00 12.00 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 11.50 12.00 12.00 12.50 12.50 12.00 12.00 11.50 11.50 11.50 11.50 12.00 12.00 12.00 12.00 EER² Cooling Capacity (BTU/h) 57,000 Furnace/Blower CHPF4860D6A*+EEP Indoor Coil 52,300 52,300 52,300 52,300 52,300 52,300 52,300 52,300 52,300 52,300 52,300 52,300 52,300 52,300 52,300 52,300 52,300 52,300 52,700 52,700 52,300 52,300 52,700 52,700 52,300 52,300 52,300 52,300 52,700 52,700 52,700 52,700 41,300 41,300 41,300 41,300 41,300 41,300 41,300 41,300 41,300 41,300 41,300 41,300 41,300 41,300 41,300 41,300 41,300 41,300 41,600 41,600 41,300 41,300 41,600 41,600 41,300 41,300 41,300 41,300 41,600 41,600 41,600 41,600 Sens. TVA Ratings³ Total 57,000 57,000 57,000 57,000 57,000 57,000 57,000 57,000 57,000 57,000 57,000 57,000 57,000 57,000 57,000 57,000 57,000 57,000 57,000 57,000 57,000 57,000 58,000 58,000 57,000 57,000 57,000 57,000 57,000 57,000 58,000 58,000 High 8.50 8.50 8.50 8.50 9.00 9.00 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.50 8.75 8.75 9.00 9.00 8.75 8.75 8.50 8.50 8.50 8.50 8.75 8.75 8.75 8.75 HSPF4 33,000 33,000 33,000 33,000 33,000 33,000 33,000 33,000 33,000 33,000 33,000 33,000 33,000 33,000 33,000 33,000 33,000 33,000 38,000 38,000 33,000 33,000 39,500 39,500 33,000 33,000 33,000 33,000 38,000 38,000 39,500 39,500 Low Heating Capacity (BTU/h) 1450130 1450129 1450128 3069035 1450127 3069034 3069037 3069036 1296670 1296669 3069033 3069032 921793 921323 3069031 3069030 1330437 1330436 1330373 3069027 1330371 3069026 1330372 3069025 3069029 3069028 923760 923681 1044499 3069022 1046129 3069021 ARI # PRODUCT SPECIFICATIONS ARI PERFORMANCE RATINGS (CONT.) See Notes on Page 30. SS-SSZ14 PRODUCT SPECIFICATIONS DIMENSIONS W D H Dimensions Model SS-SSZ14 www.goodmanmfg.com W” D” H” SSZ140181A 29 29 34¼ SSZ140241A 29 29 38¼ SSZ140301A 29 29 38¼ SSZ140361A 35½ 35¼ 38¼ SSZ140421A 35½ 35½ 38¼ SSZ140481A 35½ 35½ 38¼ SSZ140601A 35½ 35½ 38¼ 35 36 BK www.goodmanmfg.com L2 L1 1 SR BL YL IO BL/PK CM AUX MAIN HPS R R BK H V D R BK S DF1 DF2 BK RD YL/PK RD BK BK LPS DFT RVC YL BL YL/PK BK YL/PK BK L1 T1 BK L2 T2 BK BK BL BK BK RCCF YL YL BL HERM YL F RD SA (IF USED) NOTE 2 RD BR C RD RD SC YL EQUIPMENT GROUND USE COPPER CONDUCTORS ONLY RD PU C RD RD YL/PK BL/PK C NOTE 1 L1 C T1 R R IO LVDR DFT SR O M AI N X AU Y DC (IF USED) NOTE 3 DFT W2 2 CH CM IO X S AU COMP M AI N R DF2 HVDR DF1 C 5 SC C RVC (IF USED) SA RCCF C F H 1 T2 C L2 VENDOR: GOODMAN PRINT SHOP CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION. 01/06 0140R00029P C COMPONENT CODE LPS O C --------------- CONTACTOR CH ------------- CRANKCASE HEATER HPS CM ------------ OUTDOOR FAN MOTOR R C COMP -------- COMPRESSOR W2 O Y DC ------------- DEFROST CONTROL DFT ----------- DEFROST THERMOSTAT INDOOR POWER HPS-------------HIGH PRESSURE SWITCH SUPPLY HVDR -------- HIGH VOLTAGE DEFROST RELAY IO -------------- INTERNAL OVERLOAD NOTES: LPS ------------ LOW PRESSURE SWITCH 1) TO INDOOR UNIT LOW VOLTAGE LVDR --------- LOW VOLTAGE DEFROST RELAY TERMINAL BLOCK & INDOOR LVJB ---------- LOW VOLTAGE JUNCTION BOX THERMOSTAT. 2) START ASSIST FACTORY RCCF --------- RUN CAPACITOR FOR COMPRESSOR & FAN EQUIPPED WHEN REQUIRED. 3) CRANKCASE HEATER MAY BE RVC ----------- REVERSING VALVE COIL FACTORY OR FIELD INSTALLED. SA ------------- START ASSIST SC ------------- START CAPACITOR FOR COMPRESSOR (OPTIONAL) SR ------------- START RELAY FOR COMPRESSOR (OPTIONAL) USE N.E.C. CLASS 2 WIRE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRING CODE FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE COLOR CODE BK --------------- BLACK BL/PK ---------- BLUE/PINK STRIPE BR --------------- BROWN OR --------------- ORANGE PU --------------- PURPLE RD --------------- RED WH -------------- WHITE YL --------------- YELLOW YL/PK--------- YELLOW/PINK STRIPE BL Y OUTDOOR POWER SUPPLY SEE RATING PLATE High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. CH (IF USED) NOTE 3 R AUX MAIN COMP RD DFT C BK RD RD YL RD WH W2 WARNING BK O O OR BR BK PU BL/PK ALTERNATE DOUBLE POLE CONTACTOR T2 T1 YL 2 5 BL C Y LVDR DC O W2 OR BL/PK R RD WH LVJB ALTERNATE DOUBLE POLE CONTACTOR ONLY CONTROL BOX PRODUCT SPECIFICATIONS WIRING DIAGRAM Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. Copyright © 2008 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA. SS-SSZ14