Goodman Electric Heater Technical Specifications

   EMBED


Share

Transcript

Product Specifications Heat Kit Data Model Amps Circuit 1 MCA¹ MOP² Amps Circuit 2 MCA¹ MOP² Single-Point Kit MCA¹ MOP² ASPT24B14AC HKS*03XC* HKS*05XC* HKS*06XC* HKS*08XC* HKS*10XC* HKSC15*#* 0/0 10.8 / 12.5 17.3 / 20.0 21.7 / 25.0 28.9 / 33.3 34.7 / 40.0 34.7 / 40.0 3/3 17 / 19 25 / 28 30 / 34 39 / 45 46 / 53 46 / 53 15 / 15 20 / 20 25 / 30 35 / 35 40 / 45 50 / 60 50 / 60 ------------17.3 / 20 ------------22 / 25 ------------25 / 25 -------68 / 78 -------70 / 80 ASPT30C14AB HKS*03XC* HKS*05XC* HKS*06XC* HKS*08XC* HKS*10XC* HKSC15*#* 0/0 10.8 / 12.5 17.3 / 20.0 21.7 / 25.0 28.9 / 33.3 34.7 / 40.0 34.7 / 40.0 3.9 / 3.9 17 / 20 26 / 29 31 / 35 40 / 46 47 / 54 47 / 54 15 / 15 20 / 20 30 / 30 35 / 40 40 / 50 50 / 60 50 / 60 ------------17.3 / 20 ------------22 / 25 ------------25 / 25 ------69 / 79 ------70 / 80 ASPT36C14AC HKS*03XC* HKS*05XC* HKS*06XC* HKS*08XC* HKS*10XC* HKSX15XF* HKSX20XF* HKSC15*#* HKSC19*#* HKSC15XF* HKSC20XF* 0/0 10.8 / 12.5 17.3 / 20.0 21.7 / 25.0 28.9 / 33.3 34.7 / 40.0 0/0 0/0 34.7 / 40.0 34.7 / 40.0 0/0 0/0 4/4 17 / 20 26 / 29 31 / 35 40 / 46 47 / 54 4/4 4/4 47 / 54 47 / 54 4/4 4/4 15 / 15 20 / 20 30 / 30 40 / 40 40 / 50 50 / 60 15/15 15/15 50 / 60 50 / 60 15/15 15/15 ------------30/34.6 38/43 17.3 / 20 34.7 / 40 30/34.6 38/43 ------------38/43 47/54 22 / 25 43 / 50 38/43 47/54 ------------40/45 50/60 25 / 25 45 / 50 40/45 50/60 --------69 / 79 91 / 104 --- --------70 / 80 100 / 110 --- ASPT42C14A HKS*03XC* HKS*05XC* HKS*06XC* HKS*08XC* HKS*10XC* HKSX15XF* HKSX20XF* HKSC15*#* HKSC19*#* HKSC15XF* HKSC20XF* 0/0 10.8 / 12.5 17.3 / 20.0 21.7 / 25.0 28.9 / 33.3 34.7 / 40.0 0/0 0/0 34.7 / 40.0 34.3 / 40.0 0/0 0/0 4/4 17 / 20 26 / 29 31 / 35 40 / 46 47 / 54 4/4 4/4 47 / 54 47 / 54 4/4 4/4 15 / 15 20 / 20 30 / 30 35 / 40 40 / 50 50 / 60 15/15 15/15 50 / 60 50 / 60 15/15 15/15 ------------30/34.6 38/43 17.3 / 20 34.7 / 40 30 / 34.6 38 / 43 ------------38/43 47/54 22 / 25 43 / 50 38 / 43 47 / 54 ------------40/45 50/60 25 / 25 45 / 50 40 / 45 50 / 60 --------69 / 79 91 / 104 --- --------70 / 80 100 / 110 --- ASPT48C14AD HKS*03XC* HKS*05XC* HKS*06XC* HKS*08XC* HKS*10XC* HKSX15XF* HKSX20XF* HKSC15*#* HKSC19*#* HKSC15XF* HKSC20XF* 0/0 10.8 / 12.5 17.3 / 20.0 21.7 / 25.0 28.9 / 33.3 34.7 / 40.0 0/0 0/0 34.7 / 40.0 34.3 / 40.0 0/0 0/0 7/7 20 / 22 28 / 32 34 / 38 43 / 48 50 / 57 8/8 8/8 50 / 57 50 / 57 4/4 4/4 15 / 15 25 / 25 30 / 35 35 / 40 45 / 50 60 / 60 15/15 15/15 60 / 60 60 / 60 15 / 15 15 / 15 ------------30/34.6 38/43 17.3 / 20 34.7 / 40 30 / 34.6 37 / 43 ------------38/44 47/54 22 / 25 43 / 50 38 / 43 47 / 54 ------------40/45 50/60 25 / 25 45 / 50 40 / 45 50 / 60 --------72 / 82 93 / 107 --- --------80 / 90 100 / 110 --- SS-GASPT www.goodmanmfg.com 7 Product Specifications Heat Kit Data (cont.) Model Amps Circuit 1 MCA¹ MOP² Amps Circuit 2 MCA¹ MOP² Single-Point Kit MCA¹ MOP² ASPT42D14AC HKS*03XC* HKS*05XC* HKS*06XC* HKS*08XC* HKS*10XC* HKSX15XF* HKSX20XF* HKSC15*#* HKSC20*#* HKSC15XF* HKSC20XF* 0/0 10.8 / 12.5 17.3 / 20.0 21.7 / 25.0 28.9 / 33.3 34.7 / 40.0 0/0 0/0 34.7 / 40.0 34.3 / 39.6 0/0 0/0 6/6 20 / 22 28 / 31 33 / 37 42 / 48 49 / 56 6/6 6/6 49 / 56 49 / 56 6/6 6/6 15 / 15 20 / 25 30 / 35 35 / 40 45 / 50 50 / 60 15/15 15/15 50 / 60 50 / 60 15/15 15/15 ------------30/34.6 38/43 17.3 / 20 34.7 / 40 30 / 34.6 38 / 43 ------------38/43 47/54 22 / 25 43 / 50 38 / 43 47 / 54 ------------40/45 50/60 25 / 25 45 / 50 40 / 45 50 / 60 --------71 / 81 93 / 106 --- --------80 / 90 100 / 110 --- ASPT48D14AD HKS*03XC* HKS*05XC* HKS*06XC* HKS*08XC* HKS*10XC* HKSX15XF* HKSX20XF* HKSC15*#* HKSC20*#* HKSC15XF* HKSC20XF* HKSC25*#* 0/0 10.8 / 12.5 17.3 / 20.0 21.7 / 25.0 28.9 / 33.3 34.7 / 40.0 0/0 0/0 34.7 / 40.0 34.3 / 39.6 0/0 0/0 52 / 60 8/8 22 / 24 30 / 33 35.4 / 40 44 / 50 52 / 58 8/8 8/8 52 / 58 52 / 58 8/8 8/8 73 / 83 15 / 15 25 / 25 30 / 35 40 / 40 45 / 50 60 / 60 15/15 15/15 60 / 60 60 / 60 15/15 15/15 80 / 90 ------------30/34.6 38/43 17.3 / 20 34.7 / 40 30/34.6 38/43 34.7 / 40 ------------38/43 47/54 22 / 25 43 / 50 38/43 47/54 43 / 50 ------------40/45 50/60 25 / 25 45 / 50 40/45 50/60 45 / 50 --------73 / 83 95 / 108 --117 / 133 --------80 / 90 100 / 110 --125 / 150 ASPT60D14AC HKS*03XC* HKS*05XC* HKS*06XC* HKS*08XC* HKS*10XC* HKSC15*#* HKSC20*#* HKSC15XF* HKSC20XF* HKSC25*#* 0/0 10.8 / 12.5 17.3 / 20.0 21.7 / 25.0 28.9 / 33.3 34.7 / 40.0 34.7 / 40.0 34.3 / 39.6 0/0 0/0 52 / 60 8.3 / 8.3 22 / 24 30 / 33 35 / 40 44 / 50 52 / 58 52 / 58 52 / 58 8.3 / 8.3 8.3 / 8.3 73 / 83 15 / 15 25 / 25 30 / 35 40 / 40 45 / 50 60 / 60 60 / 60 60 / 60 15/15 15/15 80 / 90 ------------17.3 / 20 34.7 / 40 30/34.6 38/43 34.7 / 40 ------------22 / 25 43 / 50 38/44 47/54 43 / 50 ------------25 / 25 45 / 50 40/50 50/60 45 / 50 ------73 / 83 95 / 108 --117 / 133 ------80 / 90 100 / 110 --125 / 150 ASPT61D14AC HKS*03XC* HKS*05XC* HKS*06XC* HKS*08XC* HKS*10XC* HKSC15*#* HKSC20*#* HKSC15XF* HKSC20XF* HKSC25*#* 0/0 10.8 / 12.5 17.3 / 20.0 21.7 / 25.0 28.9 / 33.3 34.7 / 40.0 34.7 / 40.0 34.3 / 39.6 0/0 0/0 52 / 60 8.3 / 8.3 22 / 24 30 / 33 35 / 40 44 / 50 52 / 58 52 / 58 52 / 58 8.3 / 8.3 8.3 / 8.3 73 / 83 15 / 15 25 / 25 30 / 35 40 / 40 45 / 50 60 / 60 60 / 60 60 / 60 15/15 15/15 80 / 90 ------------17.3 / 20 34.7 / 40 30/34.6 38/43 34.7 / 40 ------------22 / 25 43 / 50 38/44 47/54 43 / 50 ------------25 / 25 45 / 50 40/50 50/60 45 / 50 ------73 / 83 95 / 108 --117 / 133 ------80 / 90 100 / 110 --125 / 150 ¹ Minimum Circuit Ampacity (Heater Amps + Motor Amps) X 1.25 ² Maximum Overcurrent Protection = 2.25 X Motor Amps + Heater Amps ^Circuit 1: Single-phase for Air Handlers Circuit 2: Three-phase for HKR3 Heater Kits 8 * Revision level that may or may not be designated C = Circuit Breaker Option --- indicates Not Required www.goodmanmfg.com SS-GASPT Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. SS-GASPT ⚠ L2 BK R RD TL PU WH BL BK RD BK ONE (1) ELEMENT ROWS BK M2 M1 HTR1 9 8 7 6 5 4 3 2 1 PLF RD L1 BK L2 FL FL M2 M1 RD M4 M3 TL TL BL PU BK WH RD RD BK TWO (2) ELEMENT ROWS BK RD BK R HTR2 HTR1 9 8 7 6 5 4 3 2 1 PLF L1 BK RD L2 HTR2 HTR1 BK RD YL R1 M4 M3 BK M2 M1 R2 BL TL YL BK RD TL TL WH PU BR RD BL BK THREE (3) ELEMENT ROWS L2 RD M2 RD HTR3 M1 BK L1 YL FL FL FL 9 8 7 6 5 4 3 2 1 PLF L1 BK RD L2 FL L1 YL BL HTR3 HTR2 HTR1 M2 L2 RD BL BK M6 M5 PU BK TL BL R2 M8 M7 BL RD YL TL TL TL WH BR RD BL BK 9 8 7 6 5 4 3 2 1 PLF FOUR (4) ELEMENT ROWS RD YL R1 M4 M3 BK RD HTR4 M1 BK FL FL FL Warning www.goodmanmfg.com WH GR B BL 1 4 7 A RD or BK CR BL WH PU COPPER POWER SUPPLY (USE RATING PLATE) USE MIN. 75° C FIELD WIRE RD BR WH PLF PLM RD BK 4 5 3 1 GR 4 BL 240 BL TR BL RD BK BL FUSE HOLDER (OPTIONAL) WH PU BL 3 2 24V 5 7 7 SEE NOTE 1 WH BR RD 6 6 9 9 C L GN EM 12 34 5 OR BR YL WH PU SEE NOTE 4 8 8 EQUIPMENT GROUND USE COPPER WIRE 5 5 1 BL 4 4 BL RD or BK C BK 2 BK 3 3 RD RD 2 2 1 1 GRD L2 L1 ALTERNATE HEAT RELAY IF REPLACEMENT OF THE ORIGINAL WIRES SUPPLIED WITH THIS ASSEMBLY IS NECESSARY, USE WIRE THAT CONFORMS TO THE NATIONAL ELECTRIC CODE. RD or BK GR BL RD R C G W1 W2 Y1 Y2 O DH 1 2 3 4 5 SEE NOTE 2 TR 4 24V 2 6 5 5 3 4 PLM B A SEE NOTE 1 L2 2 PLF 2 PLM R C G W 1 W2 Y1 Y2 O DH 1 2 3 4 5 1 L GN EM 208/240 VOLTS 4 3 CR 1 7 1 1) RED WIRES TO BE ON TRANSFORMER TERMINAL "3" FOR 240 VOLTS AND ON TERMINAL "2" FOR 208 VOLTS. 2) SEE COMPLETE WIRING DIAGRAMS IN INSTALLATION INSTRUCTIONS FOR PROPER LOW VOLTAGE WIRING CONNECTIONS. 3) CONFIRM SPEED TAP SELECTION IS APPROPRIATE FOR APPLICATION. IF SPEED TAP NEEDS TO BE CHANGED, CONNECT PURPLE WIRE FROM TERMINAL 4 OF CR RELAY TO APPROPRIATE TAP AT TB 4) BROWN AND WHITE WIRES ARE USED FOR HEAT KITS ONLY. 5) FUSE: 3A, 250V, 3AG CARTRIDGE FUSE. NOTES: FUSE HOLDER (OPTIONAL) 1 PLM 1 PLF L1 CR 1 2 3 4 5 C EM ALTERNATE HEAT RELAY 2 4 5 CR EM FL HTR PLF PLM R TB TR TL 0140A00063-B CONTROL RELAY EVAPORATOR MOTOR FUSE LINK HEAT ELEMENTS FEMALE PLUG CONNECTOR MALE PLUG CONNECTOR RELAY TERMINAL BOARD TRANSFORMER THERMAL LIMIT COMPONENT CODE GR GREEN BK BLACK PU PURPLE RD RED YL YELLOW BR BROWN WH WHITE BL BLUE COLOR CODE WIRING CODE FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP DOES NOT EXCEED MINIMUM BLOWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEATER KIT COMBINATION ON THIS UNIT'S S&R PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK A "X" IN THE BOX PROVIDED ABOVE.MARK ACCORDING TO NUMBER OF HEATER ELEMENT ROWS INSTALLED. NO MARK INDICATES NO HEAT KIT INSTALLED. L1 BK FL Product Specifications Wiring Diagram – Air Handler NOTE: The five element, 25 kW heater kit is not shown above. High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. ⚡ 9 Product Specifications Wiring Diagram – 5 Element Heater Kit TL HTR1 TL HTR2 TL BK FL COMPONENT CODE RD FL M10 R3 M9 HTR3 TL HTR4 BK BL BL FL TL PU PC HTR5 RD YL FL FL BK BL M2 YL PU WH BL M4 M1 2 PU BK RD M3 R1 M6 M7 M5 M8 3 RD BL R2 BK RD 1 WH BR 4 5 6 7 YL BL BK RD CB3 L1 CB1 L2 L1 8 9 L2 L1 COLOR CODE BK = BLACK BL = BLUE BR = BROWN GR = GREEN OR = ORANGE PK = PINK PU = PURPLE RD = RED WH = WHITE YL = YELLOW NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP MUST EXCEED OR EQUAL THE MINIMUM BLOWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER / HEATER KIT COMBINATION ON THIS UNIT'S SERIAL PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED BELOW. NO MARK INDICATES NO HEAT KIT INSTALLED. FIVE (5) ELEMENT ROWS NOTE:THIS LABEL MUST BE ATTACHED ON THE AIRHANDLER IN A PROMINENT LOCATION CB2 BK RD PU PC = 9 PIN CONNECTOR HTR = HEATER ELEMENT TL = THERMAL LMT RS = RELAY/SEQUENCER TB = TERMINAL BLOCK CB = CIRCUIT BREAKER CC = CONTACTOR FL = FUSE LINK EM = EVAPORATOR MOTOR EBTDR = ELEC. BLOWER TIME DELAY RC = RUN CAPACITOR TR = TRANSFORMER SR = STRAIN RELIEF WIRING CODE: HIGH VOLTAGE LOW VOLTAGE L2 BK RD CB4 L1 L2 Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. 10 0140M00274-A ⚠ Warning High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. www.goodmanmfg.com ⚡ SS-GASPT