Transcript
Product Specifications
Heat Kit Data Model
Amps
Circuit 1 MCA¹
MOP²
Amps
Circuit 2 MCA¹
MOP²
Single-Point Kit MCA¹ MOP²
ASPT24B14AC HKS*03XC* HKS*05XC* HKS*06XC* HKS*08XC* HKS*10XC* HKSC15*#*
0/0 10.8 / 12.5 17.3 / 20.0 21.7 / 25.0 28.9 / 33.3 34.7 / 40.0 34.7 / 40.0
3/3 17 / 19 25 / 28 30 / 34 39 / 45 46 / 53 46 / 53
15 / 15 20 / 20 25 / 30 35 / 35 40 / 45 50 / 60 50 / 60
------------17.3 / 20
------------22 / 25
------------25 / 25
-------68 / 78
-------70 / 80
ASPT30C14AB HKS*03XC* HKS*05XC* HKS*06XC* HKS*08XC* HKS*10XC* HKSC15*#*
0/0 10.8 / 12.5 17.3 / 20.0 21.7 / 25.0 28.9 / 33.3 34.7 / 40.0 34.7 / 40.0
3.9 / 3.9 17 / 20 26 / 29 31 / 35 40 / 46 47 / 54 47 / 54
15 / 15 20 / 20 30 / 30 35 / 40 40 / 50 50 / 60 50 / 60
------------17.3 / 20
------------22 / 25
------------25 / 25
------69 / 79
------70 / 80
ASPT36C14AC HKS*03XC* HKS*05XC* HKS*06XC* HKS*08XC* HKS*10XC* HKSX15XF* HKSX20XF* HKSC15*#* HKSC19*#* HKSC15XF* HKSC20XF*
0/0 10.8 / 12.5 17.3 / 20.0 21.7 / 25.0 28.9 / 33.3 34.7 / 40.0 0/0 0/0 34.7 / 40.0 34.7 / 40.0 0/0 0/0
4/4 17 / 20 26 / 29 31 / 35 40 / 46 47 / 54 4/4 4/4 47 / 54 47 / 54 4/4 4/4
15 / 15 20 / 20 30 / 30 40 / 40 40 / 50 50 / 60 15/15 15/15 50 / 60 50 / 60 15/15 15/15
------------30/34.6 38/43 17.3 / 20 34.7 / 40 30/34.6 38/43
------------38/43 47/54 22 / 25 43 / 50 38/43 47/54
------------40/45 50/60 25 / 25 45 / 50 40/45 50/60
--------69 / 79 91 / 104 ---
--------70 / 80 100 / 110 ---
ASPT42C14A HKS*03XC* HKS*05XC* HKS*06XC* HKS*08XC* HKS*10XC* HKSX15XF* HKSX20XF* HKSC15*#* HKSC19*#* HKSC15XF* HKSC20XF*
0/0 10.8 / 12.5 17.3 / 20.0 21.7 / 25.0 28.9 / 33.3 34.7 / 40.0 0/0 0/0 34.7 / 40.0 34.3 / 40.0 0/0 0/0
4/4 17 / 20 26 / 29 31 / 35 40 / 46 47 / 54 4/4 4/4 47 / 54 47 / 54 4/4 4/4
15 / 15 20 / 20 30 / 30 35 / 40 40 / 50 50 / 60 15/15 15/15 50 / 60 50 / 60 15/15 15/15
------------30/34.6 38/43 17.3 / 20 34.7 / 40 30 / 34.6 38 / 43
------------38/43 47/54 22 / 25 43 / 50 38 / 43 47 / 54
------------40/45 50/60 25 / 25 45 / 50 40 / 45 50 / 60
--------69 / 79 91 / 104 ---
--------70 / 80 100 / 110 ---
ASPT48C14AD HKS*03XC* HKS*05XC* HKS*06XC* HKS*08XC* HKS*10XC* HKSX15XF* HKSX20XF* HKSC15*#* HKSC19*#* HKSC15XF* HKSC20XF*
0/0 10.8 / 12.5 17.3 / 20.0 21.7 / 25.0 28.9 / 33.3 34.7 / 40.0 0/0 0/0 34.7 / 40.0 34.3 / 40.0 0/0 0/0
7/7 20 / 22 28 / 32 34 / 38 43 / 48 50 / 57 8/8 8/8 50 / 57 50 / 57 4/4 4/4
15 / 15 25 / 25 30 / 35 35 / 40 45 / 50 60 / 60 15/15 15/15 60 / 60 60 / 60 15 / 15 15 / 15
------------30/34.6 38/43 17.3 / 20 34.7 / 40 30 / 34.6 37 / 43
------------38/44 47/54 22 / 25 43 / 50 38 / 43 47 / 54
------------40/45 50/60 25 / 25 45 / 50 40 / 45 50 / 60
--------72 / 82 93 / 107 ---
--------80 / 90 100 / 110 ---
SS-GASPT
www.goodmanmfg.com
7
Product Specifications
Heat Kit Data (cont.) Model
Amps
Circuit 1 MCA¹
MOP²
Amps
Circuit 2 MCA¹
MOP²
Single-Point Kit MCA¹ MOP²
ASPT42D14AC HKS*03XC* HKS*05XC* HKS*06XC* HKS*08XC* HKS*10XC* HKSX15XF* HKSX20XF* HKSC15*#* HKSC20*#* HKSC15XF* HKSC20XF*
0/0 10.8 / 12.5 17.3 / 20.0 21.7 / 25.0 28.9 / 33.3 34.7 / 40.0 0/0 0/0 34.7 / 40.0 34.3 / 39.6 0/0 0/0
6/6 20 / 22 28 / 31 33 / 37 42 / 48 49 / 56 6/6 6/6 49 / 56 49 / 56 6/6 6/6
15 / 15 20 / 25 30 / 35 35 / 40 45 / 50 50 / 60 15/15 15/15 50 / 60 50 / 60 15/15 15/15
------------30/34.6 38/43 17.3 / 20 34.7 / 40 30 / 34.6 38 / 43
------------38/43 47/54 22 / 25 43 / 50 38 / 43 47 / 54
------------40/45 50/60 25 / 25 45 / 50 40 / 45 50 / 60
--------71 / 81 93 / 106 ---
--------80 / 90 100 / 110 ---
ASPT48D14AD HKS*03XC* HKS*05XC* HKS*06XC* HKS*08XC* HKS*10XC* HKSX15XF* HKSX20XF* HKSC15*#* HKSC20*#* HKSC15XF* HKSC20XF* HKSC25*#*
0/0 10.8 / 12.5 17.3 / 20.0 21.7 / 25.0 28.9 / 33.3 34.7 / 40.0 0/0 0/0 34.7 / 40.0 34.3 / 39.6 0/0 0/0 52 / 60
8/8 22 / 24 30 / 33 35.4 / 40 44 / 50 52 / 58 8/8 8/8 52 / 58 52 / 58 8/8 8/8 73 / 83
15 / 15 25 / 25 30 / 35 40 / 40 45 / 50 60 / 60 15/15 15/15 60 / 60 60 / 60 15/15 15/15 80 / 90
------------30/34.6 38/43 17.3 / 20 34.7 / 40 30/34.6 38/43 34.7 / 40
------------38/43 47/54 22 / 25 43 / 50 38/43 47/54 43 / 50
------------40/45 50/60 25 / 25 45 / 50 40/45 50/60 45 / 50
--------73 / 83 95 / 108 --117 / 133
--------80 / 90 100 / 110 --125 / 150
ASPT60D14AC
HKS*03XC* HKS*05XC* HKS*06XC* HKS*08XC* HKS*10XC* HKSC15*#* HKSC20*#* HKSC15XF* HKSC20XF* HKSC25*#*
0/0 10.8 / 12.5 17.3 / 20.0 21.7 / 25.0 28.9 / 33.3 34.7 / 40.0 34.7 / 40.0 34.3 / 39.6 0/0 0/0 52 / 60
8.3 / 8.3 22 / 24 30 / 33 35 / 40 44 / 50 52 / 58 52 / 58 52 / 58 8.3 / 8.3 8.3 / 8.3 73 / 83
15 / 15 25 / 25 30 / 35 40 / 40 45 / 50 60 / 60 60 / 60 60 / 60 15/15 15/15 80 / 90
------------17.3 / 20 34.7 / 40 30/34.6 38/43 34.7 / 40
------------22 / 25 43 / 50 38/44 47/54 43 / 50
------------25 / 25 45 / 50 40/50 50/60 45 / 50
------73 / 83 95 / 108 --117 / 133
------80 / 90 100 / 110 --125 / 150
ASPT61D14AC HKS*03XC* HKS*05XC* HKS*06XC* HKS*08XC* HKS*10XC* HKSC15*#* HKSC20*#* HKSC15XF* HKSC20XF* HKSC25*#*
0/0 10.8 / 12.5 17.3 / 20.0 21.7 / 25.0 28.9 / 33.3 34.7 / 40.0 34.7 / 40.0 34.3 / 39.6 0/0 0/0 52 / 60
8.3 / 8.3 22 / 24 30 / 33 35 / 40 44 / 50 52 / 58 52 / 58 52 / 58 8.3 / 8.3 8.3 / 8.3 73 / 83
15 / 15 25 / 25 30 / 35 40 / 40 45 / 50 60 / 60 60 / 60 60 / 60 15/15 15/15 80 / 90
------------17.3 / 20 34.7 / 40 30/34.6 38/43 34.7 / 40
------------22 / 25 43 / 50 38/44 47/54 43 / 50
------------25 / 25 45 / 50 40/50 50/60 45 / 50
------73 / 83 95 / 108 --117 / 133
------80 / 90 100 / 110 --125 / 150
¹ Minimum Circuit Ampacity (Heater Amps + Motor Amps) X 1.25 ² Maximum Overcurrent Protection = 2.25 X Motor Amps + Heater Amps ^Circuit 1: Single-phase for Air Handlers Circuit 2: Three-phase for HKR3 Heater Kits
8
* Revision level that may or may not be designated C = Circuit Breaker Option --- indicates Not Required
www.goodmanmfg.com
SS-GASPT
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
SS-GASPT
⚠
L2
BK
R
RD
TL
PU
WH
BL
BK
RD
BK
ONE (1) ELEMENT ROWS
BK
M2
M1
HTR1
9
8
7
6
5
4
3
2
1
PLF
RD
L1
BK
L2
FL
FL
M2
M1
RD
M4
M3
TL
TL
BL
PU
BK
WH
RD
RD
BK
TWO (2) ELEMENT ROWS
BK RD BK
R
HTR2
HTR1
9
8
7
6
5
4
3
2
1
PLF
L1
BK
RD
L2
HTR2
HTR1
BK
RD
YL
R1
M4
M3
BK
M2
M1
R2
BL
TL
YL
BK RD
TL
TL
WH
PU
BR
RD BL
BK
THREE (3) ELEMENT ROWS
L2
RD
M2
RD
HTR3
M1
BK
L1
YL
FL
FL
FL
9
8
7
6
5
4
3
2
1
PLF
L1
BK
RD
L2
FL
L1
YL
BL
HTR3
HTR2
HTR1
M2
L2
RD
BL BK
M6
M5
PU
BK
TL BL
R2
M8
M7
BL
RD YL
TL
TL
TL
WH
BR
RD BL
BK
9
8
7
6
5
4
3
2
1
PLF
FOUR (4) ELEMENT ROWS
RD
YL
R1
M4
M3
BK RD
HTR4
M1
BK
FL
FL
FL
Warning
www.goodmanmfg.com
WH
GR
B BL
1
4
7
A
RD or BK
CR
BL
WH
PU
COPPER POWER SUPPLY (USE RATING PLATE) USE MIN. 75° C FIELD WIRE
RD
BR WH
PLF PLM RD
BK
4
5 3
1
GR
4
BL
240
BL
TR
BL
RD BK
BL
FUSE HOLDER (OPTIONAL)
WH
PU
BL
3
2
24V
5
7 7
SEE NOTE 1
WH
BR
RD
6
6 9
9
C L GN
EM
12 34 5
OR BR YL
WH PU
SEE NOTE 4
8
8
EQUIPMENT GROUND USE COPPER WIRE
5
5
1
BL
4
4
BL RD or BK
C
BK
2
BK
3 3
RD
RD
2
2
1
1
GRD L2
L1
ALTERNATE HEAT RELAY
IF REPLACEMENT OF THE ORIGINAL WIRES SUPPLIED WITH THIS ASSEMBLY IS NECESSARY, USE WIRE THAT CONFORMS TO THE NATIONAL ELECTRIC CODE.
RD or BK
GR
BL
RD
R C G W1 W2 Y1 Y2 O DH 1 2 3 4 5
SEE NOTE 2
TR 4
24V
2
6 5
5
3
4 PLM
B
A
SEE NOTE 1
L2
2
PLF 2 PLM
R C G W 1 W2 Y1 Y2 O DH 1 2 3 4 5
1
L GN
EM
208/240 VOLTS
4
3
CR
1
7
1
1) RED WIRES TO BE ON TRANSFORMER TERMINAL "3" FOR 240 VOLTS AND ON TERMINAL "2" FOR 208 VOLTS. 2) SEE COMPLETE WIRING DIAGRAMS IN INSTALLATION INSTRUCTIONS FOR PROPER LOW VOLTAGE WIRING CONNECTIONS. 3) CONFIRM SPEED TAP SELECTION IS APPROPRIATE FOR APPLICATION. IF SPEED TAP NEEDS TO BE CHANGED, CONNECT PURPLE WIRE FROM TERMINAL 4 OF CR RELAY TO APPROPRIATE TAP AT TB 4) BROWN AND WHITE WIRES ARE USED FOR HEAT KITS ONLY. 5) FUSE: 3A, 250V, 3AG CARTRIDGE FUSE.
NOTES:
FUSE HOLDER (OPTIONAL)
1 PLM
1 PLF
L1
CR
1 2 3 4 5
C
EM
ALTERNATE HEAT RELAY
2
4
5
CR EM FL HTR PLF PLM R TB TR TL
0140A00063-B
CONTROL RELAY EVAPORATOR MOTOR FUSE LINK HEAT ELEMENTS FEMALE PLUG CONNECTOR MALE PLUG CONNECTOR RELAY TERMINAL BOARD TRANSFORMER THERMAL LIMIT
COMPONENT CODE
GR GREEN BK BLACK PU PURPLE RD RED YL YELLOW BR BROWN WH WHITE BL BLUE
COLOR CODE
WIRING CODE FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE
NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP DOES NOT EXCEED MINIMUM BLOWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEATER KIT COMBINATION ON THIS UNIT'S S&R PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK A "X" IN THE BOX PROVIDED ABOVE.MARK ACCORDING TO NUMBER OF HEATER ELEMENT ROWS INSTALLED. NO MARK INDICATES NO HEAT KIT INSTALLED.
L1
BK
FL
Product Specifications
Wiring Diagram – Air Handler
NOTE: The five element, 25 kW heater kit is not shown above.
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.
⚡
9
Product Specifications
Wiring Diagram – 5 Element Heater Kit TL HTR1 TL HTR2 TL
BK
FL
COMPONENT CODE
RD
FL
M10
R3
M9
HTR3 TL HTR4
BK
BL BL
FL
TL
PU PC
HTR5
RD
YL
FL
FL
BK
BL
M2
YL
PU
WH
BL
M4
M1
2
PU
BK RD
M3
R1
M6
M7
M5
M8
3
RD BL
R2
BK RD
1
WH
BR
4
5
6
7
YL BL BK RD
CB3 L1
CB1 L2
L1
8
9
L2
L1
COLOR CODE BK = BLACK BL = BLUE BR = BROWN GR = GREEN OR = ORANGE PK = PINK PU = PURPLE RD = RED WH = WHITE YL = YELLOW
NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP MUST EXCEED OR EQUAL THE MINIMUM BLOWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER / HEATER KIT COMBINATION ON THIS UNIT'S SERIAL PLATE. AFTER INSTALLING
OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED BELOW. NO MARK INDICATES NO HEAT KIT INSTALLED. FIVE (5) ELEMENT ROWS NOTE:THIS LABEL MUST BE ATTACHED ON THE AIRHANDLER IN A PROMINENT LOCATION
CB2
BK RD
PU
PC = 9 PIN CONNECTOR HTR = HEATER ELEMENT TL = THERMAL LMT RS = RELAY/SEQUENCER TB = TERMINAL BLOCK CB = CIRCUIT BREAKER CC = CONTACTOR FL = FUSE LINK EM = EVAPORATOR MOTOR EBTDR = ELEC. BLOWER TIME DELAY RC = RUN CAPACITOR TR = TRANSFORMER SR = STRAIN RELIEF WIRING CODE: HIGH VOLTAGE LOW VOLTAGE
L2
BK RD
CB4 L1
L2
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
10
0140M00274-A
⚠
Warning
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.
www.goodmanmfg.com
⚡
SS-GASPT