Goodman Specifications

   EMBED


Share

Transcript

MBVC Multi-Position Variable-Speed ECM Based ComfortNet™ Compatible Modular Blower Product Features • Variable-speed ECM blower motor • ComfortNet™ Communicating System compatible • Auto configuration of the airflow and tonnage in communicating mode • Provides constant CFM over a wide range of static pressure conditions independent of duct system • CFM indicator • Fault recall of six most recent faults • Provides adjustable low CFM for efficient fan-only operation • Improved humidity and comfort control • Built-in compatibility with multi-stage heat pump and cooling applications • 3 kW – 21 kW electric heat kits • Blower section usable as electric heater • Horizontal or vertical configuration capabilities • 21" depth for easier attic access • Foil-faced insulation covers the internal casing to reduce cabinet condensation • Galvanized, leather grainembossed finish • AHRI certified; ETL listed 1½ to 5 TONS Contents Air Handler Nomenclature .....................2 Heater Kit Nomenclature........................2 Product Specifications ............................3 Dimensions .............................................4 Airflow Data ............................................5 Heat Kit Data............................................6 Wiring Diagram .......................................7 * Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec. SS-GMBVC www.goodmanmfg.com 11/14 Supersedes 6/14 Product Specifications Nomenclature MB 1,2   VC 3,4 12 5,6 00 7,8 A 9 A 10 1 11 Design  Series MB Modular  Blower Electrical 1    208-­‐230/60/1 Motor  Speed V Variable  Speed C ComfortNet™  CompaBble Revisions A    First  Series Circuit  Breaker A    No  Circuit  Breaker B    Circuit  Breaker Airflow  Delivered 08 800  CFM 12 1200  CFM 16 1600  CFM 20 2000  CFM Factory-­‐installed  Electric  Heat 00    No  Heat       HKR X 03   X   A AA 1 2 3 4 5 6,7 Unit  Type HKR Heat  Kit  for   Air  Handlers Revisions Engineering  Revisions Phase X No  circuit  breaker C Circuit  Breaker Heating  Capacity  @  240  Volts 03 3.0  kW 05 4.5  kW 06 6.0  kW 08 8.0  kW 10 9.6  kW 15 14.4  kW 19 19.2  k@  wth  150F  limit 20 19.2  kW  with  170F  limit 25 25.0  kW A B C D E F G Phase Single  Phase  208  V Single  Phase  240  V Single  Phase  208/240  V Three  Phase  208  V* Three  Phase  240  V* Three  Phase  208/240  V* Three  Phase  460  V* C D X Cabinet  Size  (MAX) C  Cabinet D  Cabinet All  Cabinet  Sizes *  Heat  kit  requires  three-­‐phase  power  supply Heating kW Correction Factor Supply Voltage 240 230 220 210 208 Correction Factor 1.00 0.92 0.84 0.77 0.75 Multiply the 240-volt heating capacity by correction factors. 2 www.goodmanmfg.com SS-GMBVC Product Specifications Specifications Model MBVC1200AA-1 MBVC1600AA-1 MBVC2000AA-1 Blower Diameter 10" 10" 11" Width 8" 8" 10" 208 / 230 208 / 230 208 / 230 Min Circuit Ampacity 4.3 6.3 5.8 Max. Overcurrent Device (Amps) 15 15 15 Horsepower (HP) ½ ¾ ¾ Ship Weight (Lbs.) 67 80 86 Electrical Data Voltage Blower Motor • Minimum Circuit Ampacity (MCA) and Maximum Overcurrent Protection (MOP) for blower without supplemental heat installed. Refer to unit nameplate for these specifications with approved accessory heaters installed. SS-GMBVC www.goodmanmfg.com 3 Product Specifications Dimensions Side and Front Views D 3 1/4 5 C1/8 (3) KNOCKOUTS 1.125 1.375 1.750 .875 KNOCKOUT (2 PLACES) H 5 6 1/2 20" W Dimensions Model Width Depth Height MBVC1200AA-1 17½" 21" 26" MBVC1600AA-1 21" 21" 30" MBVC2000AA-1 24½" 21" 30" Top View 11.029 11" 8.840 8¾" 10.159 10¼" 13.178 13¼" 11¼" 11.209 11.209 11¼" 20.021 20⅛" 16.500 16 ½" SMALL 17½" 4 23.464 23 ½" 21" MEDIUM www.goodmanmfg.com 24½" LARGE SS-GMBVC Product Specifications Cooling / HP Airflow S1 S2 Speed Tap MBVC1200 Airflow (SCFM) MBVC1600 Airflow (SCFM) MBVC2000 Airflow (SCFM) off on off on off off on on A B C D 600 800 1000 1200 1000 1200 1400 1600 1200 1600 1800 2000 Cooling / HP / Aux Trim S3 off on off on S4 off off on on Trim Value 0 10% -10% 0 Cooling Profile S5 off on off on S6 off off on on A B C D Notes • The chart is for information only. For satisfactory operation, external static pressure must not exceed value shown on rating plate. • Use the CFM adjustment factors of .98 for horizontal left, .95 for horizontal right & .96 for downflow orientations. SS-GMBVC www.goodmanmfg.com 5 Product Specifications Heat Kit Data Models Circuit 1 Single-Point Kit Heater Amps MCA¹ MOP² Heater Amps MCA¹ MOP² MCA¹ MOP² MBVC1200AA-1A* HKR-03* HKR-05* / 05C* HKR-06* HKR-08* / -08C* HKR-10* / -10C* HKA-15C* 0/0 10.8 / 12.5 17.2 / 19.8 21.7 / 25.0 25.3 / 29.2 34.3 / 39.6 34.3 / 39.6 4.3 / 4.3 17.8 / 19.9 25.7 / 29.0 31.3 / 35.5 35.8 / 40.7 47.1 / 53.7 47.1 / 53.7 15 / 15 20 / 20 30 / 30 35 / 40 40 / 45 50 / 60 50 / 60 ------------17.2 / 19.8 ------------21.4 / 24.7 ------------25 / 25 ------------69/79 ------------70 / 80 MBVC1600AA-1A* HKR-03* HKR-05* / 05C* HKR-06* HKR-08* / -08C* HKR-10* / -10C* HKA-15C* 0/0 10.8 / 12.5 17.2 / 19.8 21.7 / 25.0 25.3 / 29.2 34.3 / 39.6 34.3 / 39.6 6.3 / 6.3 19.8 / 21.9 27.7 / 31.0 33.3 / 37.5 37.8 / 42.7 49.1 / 55.7 49.1 / 55.7 15 / 15 20 / 25 30 / 35 35 / 40 40 / 45 50 / 60 50 / 60 ------------17.2 / 19.8 ------------21.4 / 24.7 ------------25 / 25 ------------71/81 ------------80 / 90 MBVC2000AA-1A* HKR-03* HKR-05* / 05C* HKR-06* HKR-08* / -08C* HKR-10* / -10C* HKA-15C* HKA-20C* 0/0 10.8 / 12.5 17.2 / 19.8 21.7 / 25.0 25.3 / 29.2 34.3 / 39.6 34.3 / 39.6 34.3 / 39.6 5.8 / 5.8 19.3 / 21.4 27.2 / 30.5 32.8 / 37.0 37.3 / 42.2 48.6 / 55.2 48.6 / 55.2 48.6 / 55.2 15 / 15 20 / 25 30 / 35 35 / 40 40 / 45 50 / 60 50 / 60 50 / 60 ------------17.2 / 19.8 34.3 / 39.6 ------------21.4 / 24.7 42.9 / 49.5 ------------25 / 25 45 / 50 ------------70/80 92/105 ------------70 / 80 100 / 110 All ampacities noted above include air handler motor amps Circuit 1: Single-phase for Air Handlers / Circuit 2: Three-phase for HKR3 Heater Kits ¹ Minimum Circuit Ampacity (Heater Amps + Motor Amps) X 1.25 ² Maximum Overcurrent Protection = 2.25 X Motor Amps + Heater Amps 6 Circuit 2 * Revision level that may or may not be designated C = Circuit Breaker Option --- indicates Not Required HKA meets the new UL1995 requirements for 15 and 20KW heaters • Only applicable when HKA kits are included in table • MBVC and MBR models www.goodmanmfg.com SS-GMBVC BK 8 RD BK RD 8 9 YL BL BK RD 9 9   8 9 L1 L2 L1 L2 ONE (1) ELEMENT ROWS L1 L2 L1 L2 TWO (2) ELEMENT ROWS THREE (3) ELEMENT ROWS L1 L2 L1 L2 FOUR (4) ELEMENT ROWS Product Specifications NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP DOES NOT EXCEED MINIMUM BLOWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEATER KIT COMBINATION ON THIS UNIT'S INSTALLATION INSTRUCTIONS. AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED ABOVE.  MARK ACCORDING TO NUMBER OF HEATER ELEMENT ROWS INSTALLED. NO MARK INDICATES NO HEAT KIT INSTALLED. Wiring Diagram – Air Handler FL FL FL HTR2 HTR1 TL PLM BK BK TL HTR1 RD BK BK 4 BK 5 M2 M 1 R M 2 RD 6 WH BK RD RD TL PLM RD RD M2 M4 6 TL FL HTR3 TL YL HTR4 BL BL RD BL 4 M2 R2 BK RD BK TL FL HTR2 1 3 M1 R1 5 TL FL HTR1 BK RD PLM BK PU BL M3 FL 2 YL BK M1 4 RD BK BK 8 YL 3 WH 7 BK M 3 M 4 TL BK RD PU BL BK HTR3 1 2 3 M1 TL FL HTR2 PLM 1 PU BL R FL FL HTR1 2 RD BK TL BR WH 5 6 RD YL BL M1 M3 M5 M2 M4 M6 R1 BK BK RD 1 2 PU BK RD M7 M8 R2 RD BL BR 3 4    5 6 WH 7 RD 9 7 7 YL 8 BK RD 8 YL BL BK RD 9 9 8 9 L1 L2 L1 L2 ONE (1) ELEMENT ROWS L1 L2 L1 L2 TWO (2) ELEMENT ROWS THREE (3) ELEMENT ROWS L1 L2 L1 L2 FOUR (4) ELEMENT ROWS NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP DOES NOT EXCEED MINIMUM BLOWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEATER KIT COMBINATION ON THIS UNIT'S INSTALLATION INSTRUCTIONS. AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED ABOVE.  MARK ACCORDING TO NUMBER OF HEATER ELEMENT ROWS INSTALLED. NO MARK INDICATES NO HEAT KIT INSTALLED. 1 6 6 5 4 5 4 7 8 BK 2 COM 1 BK WH BL 7 8 9 SEE NOTE 7 BK 208 VAC GN DISCONNECT BL BR BL RD C 9 W1 W2 TR TH INDOOR AIR CIRCULATOR BLWR COM 4 CIRCUIT HEATER CONNECTOR SEE NOTE 5 FAULT RECALL LEARN SEE NOTE 6 24 V 3 A FUSE   SEE NOTE 6 STATUS RD CAS SEE NOTE 8 LED DEHUM ENABLE TRIM ENABLE COOL AF PROFILE W2 CONT FAN  HTR KIT(KW) GY TRIM % 1  AF SELECT 2 BL  Y1 W1  G C BK S1 S2 S3 S4 RD R S5 S6 S7 S8 S9 S10 S11 S12 S13 DIP SWITCHES 2 TWO-STAGE INTEGRATED CONTR OL MODULE 1      CIRCULATOR BLOWER 4 3 2 1 ECM MOTOR HARNESS 1 2 3 4 5 24V THERMOSTAT CONNECTIONS    W2 Y2 W2 (2) CAS (1) Y1 TO MICRO   HEAT 2  COIL/ R2   CONDENSATE SWITCH CAS (2) +VDC (1) G RX (2) O INDOOR AIR CIRCULATOR BLWR TX (3) DEHUM GRND (4) TR GN RD L2    40 VA  FUSE 3 A TRANSFORMER TH    R   24 VAC       W1 (1) HEAT 1 COIL/R1  W1        C BK   GRND 208/230 VAC L1 24 V THERMOSTAT CONNECTIONS 3 4 CIRCUIT MOTOR CONNECTOR 7 SEGMENT DIAGNOSTIC  DEHUM DISPLAY O CFM LED 4 SEE NOTE 6 Y2 RX LED  L2 GRND GRND 24 VAC 1 1 4   3 RD 3 RD 3      RD 2 3 230 VAC 2 2 L1 40 VA TRANSFORMER, SEE NOTE 1 PL1 PL2 COM INTEGRATED CONTROL MODULE GRND GRND INTEGRATED CONTROL LOW VOLTAGE (24V) LOW VOLTAGE FIELD NOTES: 1. PLACE RED WIRES ON TRANSFORMER TERMINAL 2 FOR 208 VAC OPERATION. HI VOLTAGE (230V) 2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING. HI VOLTAGE FIELD 3. IF ANY OF THE ORIGINAL WIRES AS SUPPLIED WITH THIS UNIT MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105°C. USE COPPER CONDUCTORS ONLY. JUNCTION TERMINAL INTERNAL TO 4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C AND LOCAL CODES. 5. TO RECALL THE LAST 6 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY (NO THERMOSTAT INPUTS) EQUIPMENT GRND 6. RED STATUS LED PROVIDES NETWORK STATUS. GREEN RX LED INDICATES NETWORK TRAFFIC. USE LEARN BUTTON TO RESET NETWORK. FIELD GRND FIELD SPLICE 7. DISCARD CONNECTOR PL1 WHEN INSTALLING OPTIONAL HEAT KIT. 8. THE CONDENSATE ALARM SWITCH (CAS) TERMINALS CAN ONLY BE UTILIZED WITH COMMUNICATING MODE SETUPS AND MUST BE ENABLED WITH A COMMUNICATING THERMOSTAT. THIS FEATURE IS NOT OPERATIONAL WITH LEGACY SYSTEMS. USE N.E.C CLASS 2 WIRE. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. SS-GMBVC RESISTOR OVERCURRENT PROT. DEVICE PLUG CONNECTION ⚠ Warning COLOR CODES: PK ---- PINK BR ---- BROWN WH ---- WHITE BL ---- BLUE GY ---- GRAY RD ---- RED YL ---- YELLOW OR ---- ORANGE PU ---- PURPLE GN ---- GREEN BK ---- BLACK 0140A00244-A High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. www.goodmanmfg.com ⚡ 7 Product Specifications Wiring Diagram – 5 Element Heater Kit TL HTR1 BK FL TL HTR2 RD FL TL COMPONENT CODE M10 R3 M9 HTR3 HTR4 BK BL BL FL TL PU PC HTR5 RD YL FL TL FL BK BL M2 YL PU WH BL M4 M1 2 PU BK RD M3 R1 M6 M7 M5 M8 3 RD BL R2 BK RD 1 WH BR 4 5 6 7 YL BL BK RD CB3 L1 CB1 L2 L1 8 9 L2 COLOR CODE BK = BLACK BL = BLUE BR = BROWN GR = GREEN OR = ORANGE PK = PINK PU = PURPLE RD = RED WH = WHITE YL = YELLOW NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP MUST EXCEED OR EQUAL THE MINIMUM BLOWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER / HEATER KIT COMBINATION ON THIS UNIT'S SERIAL PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED BELOW. NO MARK INDICATES NO HEAT KIT INSTALLED. FIVE (5) ELEMENT ROWS NOTE:THIS LABEL MUST BE ATTACHED ON THE AIRHANDLER IN A PROMINENT LOCATION CB2 BK RD PU PC = 9 PIN CONNECTOR HTR = HEATER ELEMENT TL = THERMAL LMT RS = RELAY/SEQUENCER TB = TERMINAL BLOCK CB = CIRCUIT BREAKER CC = CONTACTOR FL = FUSE LINK EM = EVAPORATOR MOTOR EBTDR = ELEC. BLOWER TIME DELAY RC = RUN CAPACITOR TR = TRANSFORMER SR = STRAIN RELIEF WIRING CODE: HIGH VOLTAGE LOW VOLTAGE L1 L2 BK RD CB4 L1 L2 Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. 0140M00274-A ⚠ Warning High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. ⚡ Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. © 2014 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA. 8 www.goodmanmfg.com SS-GMBVC