Preview only show first 10 pages with watermark. For full document please download

Gp 12400 Battery

   EMBED


Share

Transcript

Powered by GP 12400 12V 40Ah GP 12400 is a general purpose battery up to 5 years in standby service or more than 260 cycles at 100% discharge in cycle service. As with all CSB batteries, all are rechargeable, highly efficient, leak proof and maintenance free. Specification Cells Per Unit Voltage Per Unit Capacity Weight Maximum Discharge Current Internal Resistance Operating Temperature Range 6 12 40A h @ 20hr-rate to 1.75V per cell @25°C (77°F) Approx. 12.63 kg(27.84 lbs) 400A(5sec) Approx. 8.1mΩ Discharge: -15°C~50°C( 5°F~122°F) Charge: -15°C~40°C ( 5°F~104°F) Storage:-15°C~40°C ( 5°F~104°F) Nominal Operating Temperature Range Float Charging Voltage Recommended Maximum Charging Current Limit Equalization and Cycle Service Self Discharge 25°C±3°C (77°F±5°F) 13.5 to 13.8 VDC/unit Average at 25°C (77°F) 12A Terminal Container Material Dimensions : TUV Asia Pacific Ltd. Taiwan Branch 14.4 to 15.0 VDC/unit Average at 25°C (77°F) CSB Batteries can be stored for more than 6 months at 25°C (77°F). Please charge batteries before using. For higher temperatures the time interval will be shorter. CSB-manufactured VRLA (Absorbent Glass Mat type) batteries are UL-recognized components under UL1989. B2-L terminal (M5 bolt) or Recessed type (M6 bolt) ABS(UL 94-HB) & Flammability resistance of (UL 94-V0) can be available upon request. CSB is also certified by ISO 9001 and ISO 14001. Overall Height (H) 170±2 (6.69±0.08) Unit: mm (inch) TUV Asia Pacific Ltd. Taiwan Branch Container height (h) 168.5±2 (6.63±0.08) Length (L) 197±2 (7.76±0.08) Width (W) 165±2 (6.5±0.08) Drawing of recessed terminal (http://www.csb-battery.com) The system of manufacturer was certified by TUV CERT according to ISO 9001,ISO 14001. Constant Current Discharge Characteristics Unit:A (25°C,77°F) F.V/Time 1.60V 1.67V 1.70V 1.75V 1.80V 1.85V 5MIN 176 157 149 135 121 107 10MIN 113 105 101 95.0 88.3 81.7 15MIN 85.0 81.0 78.7 75.5 71.7 67.8 30MIN 51.8 50.8 50.1 49.0 47.6 46.2 60MIN 30.6 30.3 30.2 30.0 29.8 29.4 90MIN 22.2 22.1 21.9 21.8 21.7 21.5 2HR 17.7 17.6 17.5 17.4 17.3 17.2 3HR 12.6 12.5 12.4 12.3 12.2 12.1 Constant Power Discharge Characteristics F.V/Time 1.60V 1.67V 1.70V 1.75V 1.80V 1.85V 5MIN 2110 1886 1790 1620 1450 1280 10MIN 1350 1259 1214 1140 1060 980 15MIN 1020 972 945 902 860 814 30MIN 622 606 600 585 571 555 60MIN 367 364 363 360 357 353 90MIN 266 264 263 262 260 258 2HR 212 211 210 209 208 207 5HR 8.01 7.98 7.96 7.93 7.88 7.85 8HR 5.25 5.19 5.17 5.10 5.03 4.96 10HR 4.28 4.19 4.16 4.09 4.03 3.96 20HR 2.21 2.11 2.08 2.00 1.93 1.85 10HR 51.3 50.4 50.0 49.2 48.3 47.5 20HR 26.5 25.4 24.9 24.1 23.2 22.4 Unit:W(25°,77°F) 3HR 151 150 149 148 147 146 5HR 96.1 95.7 95.5 95.2 94.8 94.2 8HR 63.0 62.3 62.0 61.2 60.4 59.6 Ratings presented herein are subject to revision without notice. Please refer to www.csb-battery.com to confirm the latest version. RA1407 GP12400 140 0.20 2.60 120 0.17 2.40 100 0.14 2.20 80 0.11 2.00 60 0.08 1.80 40 0.05 1.60 20 0.02 1.40 0 140 0.20 2.60 120 0.17 2.40 100 0.14 2.20 80 0.11 2.00 60 0.08 1.80 40 0.05 1.60 20 0.02 1.40 0 Application 12V 40Ah )Ratio 13.65V (2.275V/Cell) 4 8 12 16 20 24 68 )Ratio 4 8 12 16 Charge Voltage(V/Cell) Set Point Allowable Range Cycle Use Temperature 25 (77 ) 2.45 2.40~2.50 Standby 25 (77 ) 2.275 2.25~2.30 GLOBAL HQ CSB BATTERY CO., LTD. (TAIWAN) Tel : +886-2-2880-5600 Fax : +886-2-2888-3300 mail : [email protected] BEIJING OFFICE. (CHINA) CSB BATTERY TECHNOLOGIES (BEIJING) CO., LTD. Tel : +86-10-5820-5336/5338 Fax : +86-10-58203053 mail : [email protected] 20 24 Max.Charge Current Final Discharge Voltage V/Cell 1.75 1.70 1.60 1.30 0.3C Discharge Current(A) 0.2C>(A) 0.2C<(A)<0.5C 0.5C<(A)<1.0C (A)>1.0C AMERICA HQ CSB BATTERY TECHNOLOGIES INC. (U.S.A) Tel : +1-817-244-7777/1-(800)3-CSB-USA(272872) Fax : +1-817-244-4445 mail : [email protected] SHANGHAI OFFICE. (CHINA) CSB BATTERY LOGISTIC (SHANGHAI) CO., LTD. Tel : +86-21-5046-1622/5046-0833 Fax : +86-21-5064-1046 mail : [email protected] EUROPE HQ CSB Battery Europe BV. Tel : +31(0)-180-418-140 Fax : +31(0)-180-418-327 mail : [email protected] SHENZHEN OFFICE.( CHINA ) CSB BATTERY LOGISTIC ( SHANGHAI ) CO., LTD. Tel : +86-755-8831-6488/6396/6356 Fax : +86-755-8831-6548 mail : [email protected]