Preview only show first 10 pages with watermark. For full document please download

Gp1 Data Logger

   EMBED


Share

Transcript

P.O. Box 4, 6987 ZG Giesbeek Nijverheidsstraat 30, 6987 EM Giesbeek, The Netherlands T +31 313 880200 F +31 313 880299 E [email protected] I http://www.eijkelkamp.com GP1 Data Logger PRODUCT INFORMATION The GP1 Data Logger is a compact research grade data logger  High accuracy 7 channel data logging  Smart relay suitable for irrigation control  Waterproof IP67 enclosure  600,000 readings Overview The GP1 can take readings from: ► ► ► ► 2 Soil water content sensors (or other voltages) 2 Temperature sensors (or 2 x SM300s or 2 x SM150s) 2 Pulse counters (for rainfall, wind speed or water meter) 1 Delta-T WET sensor Ease of use The GP1 provides a complete solution for recording high accuracy soil moisture data in the field. Its powerful control capabilities and simple software interface make it easy to configure the GP1 either as a stand-alone irrigation controller or for adding soil moisture sensing to existing control systems. With its simple software, long battery life and large memory, the GP1 is very easy to set up and maintain. It is well suited to outdoor logging applications - the waterproof (IP67) case does not require a secondary enclosure. The GP1's small size allows it to be installed in confined spaces, or to be hidden away if security is an issue. The internal alkaline battery lasts for >1 year when taking hourly readings from 2 moisture sensors, 2 temperature sensors and a rain gauge . Applications  Monitoring soil moisture  Environmental data logging  Controlling irrigation AP.21.12.01.E GP1 Sensors 2 x Differential voltage channels 2 x Counter channels The GP1 provides 2 differential voltage channels that are ideal for connecting ML3, SM300 or SM150 soil moisture sensors. Readings are converted into %volume and can be used to control irrigation (see panel below). Each channel has an input range of -0.2 to +2.7 Volts and a resolution of 1mV, enabling it to support a wide range of environmental sensors. Sensors can be powered by a configurable warm-up from either the switched battery power or from the +5V reference. The GP1 includes one fast and one slow counter for connection to pulse output and contact closure sensors. The fast counter can record pulses up to 33kHz and is suitable for most digital anemometers. Either counter can record switch closures up to 50Hz and so is suitable for connection to a rain gauge or flow meter. 1 x WET Sensor channel 2 x Temperature channels The two temperature channels are optimised for 10k thermistor probes and provide accurate temperature readings over the range -20 to +60°C. Either channel can alternatively be used with an SM300 or SM150 sensor in order to log readings from additional soil moisture sensors. Bridge sensors, tensiometers The optional GP-PBA-X50 precision bridge adapter board converts the input from a voltage channel into a precision bridge suitable for recording readings from a pressure transducer tensiometer. It is possible to fit 2 PBA adapters into each GP1. Other pressure transducers and bridge sensors can also be used with the PBA adapter. Communications Data can easily be collected by laptop using the RS232 connection, or remotely using the GSM modem options –further information is available on request. Up to 10 GP1s can be networked together in order to share communications. The GP1 can connect to a Delta-T WET Sensor to provide readings of water content, electrical conductivity and temperature. Specialist calibrations are available for a range of horticultural substrates including mineral wool, peat-based composts and coconut fibre (coir). 1 x Relay channel output The GP1 has a highly versatile relay channel which can be controlled by multiple sensor thresholds, allowing researchers to set alarm conditions or to control and adjust experimental conditions. Both simple and highly complex control is possible (see the Irrigation panel). Power The GP1 is very power efficient and a single 9V alkaline battery will typically last for a full year when taking hourly readings. Alternatively it can be powered from an 11 to 24V DC external power source or from a solar panel. Sealing The small (140 x 105 x 45mm) enclosure is fully sealed to IP67, doing away with the need for an expensive additional enclosure for simple field applications. WS-GP1 Weather Station Other Features Reading frequency The GP1 can be configured to record readings at any frequency from 1 second to 24 hours. All sensors are recorded at the same rate. Memory The GP1 stores over 600,000 readings in non-volatile flash memory ensuring data security in the event of a flat battery. The GP1 provides the logging engine for this compact and robust weather station, which records wind speed, wind direction, rainfall, solar radiation, relative humidity and air temperature – see separate data sheet. Data Logger Configuring the GP1 DeltaLINK The free DeltaLINK software supplied with the GP1 enables full configuration, sensor checking (including real-time graphing) and data collection from the logger. Collected data can be graphed directly in DeltaLINK or imported into Excel using the data import wizard. Specialist configuration programs are provided for irrigation control and for use with the BF5 Sunshine Sensor and SPN1 Sunshine Pyranometer (illustrated below). Po of DeltaLINK is available in a coeld format using a Windows Mobile PDA and the optional Pocket DeltaLINK software. Irrigation Control Using soil moisture sensors to control irrigation has many potential benefits, including:  Reduced water use (typically 30% less than manual or timer-based control)  More compact plants  Reduced leaching due to run-through  and/or root death due to waterlogging Reduced labour associated with pruning, weeding and manual watering The GP1 control facilities have been optimised for controlling irrigation either directly or by adding sensor-based control to existing installations. Irrigation can be controlled by independently set ON and OFF conditions using any combination of:       Soil moisture conditions Temperature Light levels / sunshine status Rainfall Time of day Other sensor output Irrigation rate The control options in DeltaLINK also allow the rate of irrigation to be adjusted by setting an irrigation duty cycle between 1 and 100%. This is often necessary to give time for the irrigation water to permeate through the soil or compost down to the installed soil moisture sensor(s), but also helps to further reduce run-through or waterlogging. Monitoring irrigation conditions As well as controlling irrigation, the GP1 can provide a valuable record of soil moisture conditions, irrigation times and control levels, and water use. This may be important for research or for irrigation compliance and water abstraction licensing. Typical applications     Hardy nursery stock Protected crops Soft fruit Amenity and landscape irrigati GP1 Specifications Voltage accuracy Differential Voltage Channels Bridge Sensors Power Relay Channel Data Recording Physical Max -20°C to +60°C ± (0.3mV+0.01% reading) 3 Notes ± (1.6mV+0.05% reading) -3 3 -3 over full -0.2V to +2.7V voltage range Soil moisture accuracy ±0.06%vol (±0.0006 m .m ) ±0.3%vol (±0.003 m .m ) with ML2 or SM200 (0 to 60%vol) [1] Resolution / input noise ±0.1mV effective resolution of readings (typical) Input voltage range -0.2V to +2.7V exceeds 0 to 2.5V range Input voltage limits -2.8V to +3.6V [2] IN+ and IN- terminals relative to GND Accuracy ± (0.1mV+0.06% reading) ± (0.2mV+0.08% reading) requires GP-PBA-X50 adapter board ±0.07°C ±0.1°C [3] 10K thermistor measuring -20 to +60°C [4] Temperature Temperature accuracy Channels Resistance accuracy Event Counters Typical at +20°C ±0.2% reading (max ±0.3%) ±0.5% reading (2K to 20K) 2K to 100KΩ Event counter (Event6) < 50Hz, contact closure or pulse/logic inputs Fast counter (Event5) < 33kHz, pulse/logic. <100Hz, contact closure logic low input < 1V, logic high input > 1.9V, maximum ±14V on Event inputs 5 and 6 Internal battery life 1 year typical 9V alkaline PP3 battery [5] External power 11 to 24V DC power via external M8 connector Switched sensor power up to 120mA switched battery voltage (5 to 9V) Switched +5V reference 5V ±0.2% 1 x relay SPST, < 30V DC or < 24V AC, 1A resettable fuse separate ON / OFF conditions adjustable ON duty cycle Logging frequency 1 second to 24 hour user configurable logging frequency Sensor warm-up multiples of 1 second user configurable sensor warm-up times Internal flash memory > 600,000 readings, typical non-volatile flash memory Communications RS232 (115 kbaud) comms via external M8 connector Environmental waterproof, buriable (to 0.5m) IP67 4 cable glands, connector & case Size and weight 140 x 105 x 45mm, 280g including battery Temperature -20 to +60°C [5] contact Delta-T for applications requiring extended temperature ranges 5V ±1.6% switched +5V for sensors, up to 50mA [1] GP1 accuracy, not including sensor errors [2] Common Mode Rejection > 66dB (78dB typical) [3] GP1 at 30°C or below for -20 to 0°C reading [4] 10K thermistor error contributes typically 0.1 or 0.2°C [5] When logging 2 x SM300s and 2 x 10k thermistors hourly Ordering Information Other Loggers and Systems Data Logger type GP1 including DeltaLINK software and RS232 cable. Optional accessories: Mounting Kit type GP1-MP1 stainless steel mounting plate with fittings for up to 51mm diameter tube or post. All Delta-T loggers can be supplied with a range of modem, solar power and networking options. The GP2 is an advanced 12 channel logger and controller that is easy to use, versatile and rugged. Expansion Lid type GP1-LID2 provides 4 more cable glands. The DL2e can take readings from up to 62 input channels for larger logging applications. External Power Cable type GP1-EPC1 for external powering from a 12 to 24V DC source. The DL6 provides 6 analogue inputs and is ideal for logging a PR2/4 or PR2/6 Profile Probe. Precision Bridge Adapter Board type GP-PBA-X50 converts an input voltage channel to read tensiometers or other precision bridge sensors; 1 or 2 may be fitted to a GP1. The WS-GP1 Weather Station is a compact and portable package featuring the GP1 and 6 standard weather sensors. USB-RS232 Adapter Cable connects to PC’s USB port. GP1 M8 Cabling and Network Accessories - please enquire. The WS-GP2 Weather Station is a powerful, rugged and flexible system. Ideal for demanding research and monitoring projects. For these or other products, please request additional data sheets or see the Delta-T web site. P.O. Box 4, 6987 ZG Giesbeek Nijverheidsstraat 30, 6987 EM Giesbeek, The Netherlands T F E I +31 313 880200 +31 313 880299 [email protected] http://www.eijkelkamp.com