GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Cooling Capacity: 24,000 - 57,500 BTU/H Contents Nomenclature......................................... 2 Product Specifications............................ 3 Expanded Cooling Data.......................... 5 Airflow Data.......................................... 18 Heater Kit Specifications ..................... 20 Dimensions........................................... 22 Wiring Diagram..................................... 23 Accessories........................................... 24 Standard Features • Energy-efficient compressor • EEM blower motor • Quiet horizontal discharge • Copper tube / aluminum fin condenser coil • Totally enclosed, permanently lubricated condenser fan motor • Fully charged system • 5 kW to 20 kW electric heat kit available as a field-installed option • AHRI Certified; ETL Listed Cabinet Features • Heavy-gauge galvanized-steel cabinet with attractive Architectural Gray powder-paint finish • Fully insulated blower compartment with convenient access panels • Louvered condenser coil protection • One footprint; three heights * Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec. SS-GPC14H www.goodmanmfg.com 9/14 Supersedes 11/13 Product Specifications Nomenclature G 1   C 3 14 4,5 36 6,7 M 8 4 9 1 10 A 11 * 12 Brand G Goodman®  brand Engineering   Minor  Revision Product  Category P Packaged  Unit   Type H Heat  Pump C Air  CondiJoner Engineering   Major  Revision Efficiency 13 13  SEER 14 14  SEER Nominal  Capacity 24 2  Tons 30 2½  tons 36 3  Tons 2 P 2   Voltage  Designator 1        208-­‐230/1/60 3        208-­‐230/3/60 Refrigerant 4        R-­‐410A 15      15  SEER 16      16  SEER ConfiguraDon H        Horizontal M        MulJ-­‐posiJon 42      3½  Tons 48      4  Tons 60      5  Tons www.goodmanmfg.com SS-GPC14H Product Specifications Specifications GPC14 24H41C* GPC14 24H41D* GPC14 24H41E* GPC14 30H41C* GPC14 30H41D* GPC14 30H41E* 23,600 17,700 14.0 / 12.0 76 5732583 23,600 17,700 14.0 / 12.0 76 6892353 23,600 17,700 14.0 / 12.0 76 7428120 28,400 21,600 14.0 / 12.0 76 5677886 28,400 21,600 14.0 / 12.0 76 6892355 28,400 21,600 14.0 / 12.0 76 7428122 EEM 10 x 8 875 800 1.5 5 ½ - 1050 EEM 10 x 8 875 800 1.5 5 ½ - 1050 EEM 10 x 8 875 800 1.5 5 ½ - 1050 EEM 10 x 8 1,050 950 1.86 5 ½ - 1050 EEM 10 x 8 1,050 950 1.86 5 ½ - 1050 EEM 10 x 8 1,050 950 1.86 5 ½ - 1050 4.66 3/ 16 0.057 20 x 20 x 1 X ¾" 60 4.66 3/ 16 0.057 20 x 20 x 1 X ¾" 60 5.25 3/ 14 0.055 20 x 20 x 1 X ¾" 51 5.25 3/ 16 0.062 20 x 25 x 1 X ¾" 61 5.25 3/ 16 0.062 20 x 25 x 1 X ¾" 61 5.25 3/ 14 0.063 20 x 25 x 1 X ¾" 46 Condenser Fan / Coil Horsepower - RPM RLA/LRA Fan Diameter/ # Fan Blades Face Area (ft²) Rows Deep/ Fins per Inch 1/6 - 815 1.1 / 1.7 22 / 2 12.3 1 / 26 1/6 - 815 1.1 / 1.7 22 / 2 12.3 1 / 26 1/6 - 815 1.1 / 1.7 22 / 2 9.3 1 / 27 1/6 - 815 1.1 / 1.7 22 / 2 12.3 1 / 26 1/6 - 815 1.1 / 1.7 22 / 2 12.3 1 / 26 1/6 - 815 1.1 / 1.7 22 / 2 9.3 1 / 27 Compressor Quantity / Type Stage Compressor RLA/LRA 1 / Rotary Single 7.7/37 1 / Rotary Single 7.7/37 1 / Rotary Single 7.7/37 1 / Scroll Single 12.8 / 64 1 / Scroll Single 12.8 / 64 1 / Scroll Single 14.1/ 64 Electrical Data Voltage-Phase (60 Hz) Indoor Blower FLA Outdoor Fan RLA Total Unit Amps Min. Circuit Ampacity¹ Max. Overcurrent Protection (amps)² 208/230-1 1.5 1.1 10.3 12.2 15 208/230-1 3.8 1.1 12.6 15 20 208/230-1 3.8 1.1 12.6 15 20 208/230-1 1.86 1.1 15.76 19 30 208/230-1 3.8 1.1 17.7 21 30 208/230-1 3.8 1.1 19 23 35 305 310 305 310 300 305 310 315 310 315 305 310 Models Cooling Capacity Cooling Capacity (BTU/h) Sensible BTU/h SEER / EER Decibels AHRI Numbers Evaporator Motor Type Wheel (D x W) Cooling CFM Fan-Only CFM RLA No. of Speeds Horsepower - RPM Evaporator Coil Face Area (ft²) Rows Deep/ Fins per Inch Indoor Orifice Size Filter Size (") All-aluminum coil Drain Size (NPT) Refrigerant Charge (oz.) Ship Weight (lbs) Operating Weight (lbs) ¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ² May use fuses or HACR-type circuit breakers of the same size as noted. Note: Always check the S&R plate for electrical data on the unit being installed. SS-GPC14H www.goodmanmfg.com 3 Product Specifications Specifications (cont.) GPC14 36H41C* GPC14 36H41D* GPC14 42H41C* GPC14 42H41D* GPC14 42H41E* GPC14 48H41C* 35,600 27,100 14.0 / 12.0 78 5677887 35,600 27,100 14.0 / 12.0 78 6892357 40,000 30,400 14.0 / 12.0 78 5677888 40,000 30,400 14.0 / 12.0 78 6892358 40,000 30,400 14.0 / 12.0 78 7428124 46,000 35,300 14.0 / 12.0 80 5677889 EEM 10 x 8 1,200 1,100 1.86 5 ½ - 1050 EEM 10 x 8 1,200 1,100 1.86 5 ½ - 1050 EEM 10 x 8 1,200 1,200 2.9 5 ½ - 1050 EEM 10 x 8 1,200 1,200 2.9 5 ½ - 1050 EEM 10 x 8 1,300 1,200 2.9 5 ½ - 1050 EEM 10 x 8 1,600 1,400 2.9 5 ¾ - 1050 5.25 3/ 14 0.068 25 x 25 x 1 X ¾" 65 5.25 3/ 14 0.068 25 x 25 x 1 X ¾" 65 6.2 4/ 14 0.072 (2) 20 x 20 x 1 X ¾" 94 6.20 4/ 14 0.072 (2) 20 x 20 x 1 X ¾" 94 6.20 4/ 14 0.076 (2) 20 x 20 x 1 X ¾" 70 6.2 4/ 14 0.078 (2) 20 x 20 x 1 X ¾" 90 Condenser Fan / Coil Horsepower - RPM RLA/LRA Fan Diameter/ # Fan Blades Face Area (ft²) Rows Deep/ Fins per Inch ¼ - 830 1.5 / 3.0 22 / 3 12.3 1 / 26 ¼ - 830 1.5 / 3.0 22 / 3 12.3 1 / 26 ¼ - 1075 1.4 / 2.9 22 / 4 16 1 / 28 ¼ - 1075 1.4 / 2.9 22 / 4 16 1 / 28 ¼ - 1075 1.4 / 2.9 22 / 4 12.3 1 / 27 ¼ - 1075 1.4 / 2.9 22 / 4 19.5 1 / 28 Compressor Quantity / Type Stage Compressor RLA/LRA 1 / Scroll Single 16.7 / 79 1 / Scroll Single 16.7 / 79 1 / Scroll Single 17.9 / 112 1 / Scroll Single 17.9 / 112 1 / Scroll Single 17.9 / 112 1 / Scroll Single 19.9 / 109 208/230-1 1.86 1.5 20.06 24.2 40 208/230-1 3.8 1.5 22 26 40 208/230-1 2.9 1.4 22.2 26.6 40 208/230-1 3.8 1.4 23.1 28 45 208/230-1 3.8 1.4 23.1 28 45 208/230-1 2.9 1.4 24.2 29.1 45 315 320 315 320 360 365 360 365 350 355 370 375 Models Cooling Capacity Cooling Capacity (BTU/h) Sensible BTU/h SEER / EER Decibels AHRI Numbers Evaporator Motor Type Wheel (D x W) Cooling CFM Fan-Only CFM RLA No. of Speeds Horsepower - RPM Evaporator Coil Face Area (ft²) Rows Deep/ Fins per Inch Indoor Orifice Size Filter Size (") All-aluminum coil Drain Size (NPT) Refrigerant Charge (oz.) Electrical Data Voltage-Phase (60 Hz) Indoor Blower FLA Outdoor Fan RLA Total Unit Amps Min. Circuit Ampacity¹ Max. Overcurrent Protection (amps)² Ship Weight (lbs) Operating Weight (lbs) ¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ² May use fuses or HACR-type circuit breakers of the same size as noted. Note: Always check the S&R plate for electrical data on the unit being installed. 4 www.goodmanmfg.com SS-GPC14H Product Specifications Specifications (cont.) GPC14 48H41D* GPC14 48H41E* GPC14 60H41C* GPC14 60H41D* GPC14 60H41E* 46,000 35,300 14.0 / 12.0 80 6892361 46,000 35,300 14.0 / 12.0 80 7428126 57,500 40,800 14.0 / 12.0 80 5677890 57,500 40,800 14.0 / 12.0 80 6892362 57,500 40,800 14.0 / 11.5 80 7428128 EEM 10 x 8 1,600 1,400 2.9 5 ¾ - 1050 EEM 10 x 8 1,600 1,400 2.9 5 ¾ - 1050 EEM 11 x 8 1,600 1,700 2.9 5 ¾ - 1050 EEM 11 x 8 1,600 1,700 2.9 5 ¾ - 1050 EEM 11 x 8 1,600 1,700 2.9 5 ¾ - 1050 6.20 4/ 14 0.078 (2) 20 x 20 x 1 X ¾" 90 6.20 4/ 14 0.076 (2) 20 x 20 x 1 X ¾" 85 7 4/ 14 0.086 (2) 20 x 25 x 1 X ¾" 110 7.00 4/ 14 0.086 (2) 20 x 25 x 1 X ¾" 110 7.00 4/ 14 0.086 (2) 20 x 25 x 1 X ¾" 103 ¼ - 1075 1.4 / 2.9 22 / 4 19.5 1 / 28 ¼ - 1075 1.4 / 2.9 22 / 4 16 1 / 27 ¼ - 1075 1.4 / 2.9 22 / 4 17 2 /28 ¼ - 1075 1.4 / 2.9 22 / 4 17 2 /28 ¼ - 1075 1.4 / 2.9 22 / 4 15 2 /27 Compressor Quantity / Type Stage Compressor RLA/LRA 1 / Scroll Single 19.9 / 109 1 / Scroll Single 19.9 / 109 1 / Scroll Single 26.4 / 134 1 / Scroll Single 26.4 / 134 1 / Scroll Single 26.4 / 134 Electrical Data Voltage-Phase (60 Hz) Indoor Blower FLA Outdoor Fan RLA Total Unit Amps Min. Circuit Ampacity¹ Max. Overcurrent Protection (amps)² 208/230-1 5.4 1.4 26.7 32 50 208/230-1 5.4 1.4 26.7 32 50 208/230-1 2.9 1.4 30.7 37.3 60 208/230-1 5.4 1.4 33.2 40 60 208/230-1 5.4 1.4 33.2 40 60 370 375 365 370 375 380 375 380 370 375 Models Cooling Capacity Cooling Capacity (BTU/h) Sensible BTU/h SEER / EER Decibels AHRI Numbers Evaporator Motor Type Wheel (D x W) Cooling CFM Fan-Only CFM RLA No. of Speeds Horsepower - RPM Evaporator Coil Face Area (ft²) Rows Deep/ Fins per Inch Indoor Orifice Size Filter Size (") All-aluminum coil Drain Size (NPT) Refrigerant Charge (oz.) Condenser Fan / Coil Horsepower - RPM RLA/LRA Fan Diameter/ # Fan Blades Face Area (ft²) Rows Deep/ Fins per Inch Ship Weight (lbs) Operating Weight (lbs) ¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ² May use fuses or HACR-type circuit breakers of the same size as noted. Note: Always check the S&R plate for electrical data on the unit being installed. SS-GPC14H www.goodmanmfg.com 5 6 www.goodmanmfg.com 24.5 0.84 21 1.48 6.6 225 111 23.8 0.80 21 1.47 6.6 223 110 22.0 0.77 22 1.43 6.4 216 107 MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR 720 820 920 59 24.1 0.74 18 1.47 6.6 223 110 23.4 0.71 19 1.45 6.5 220 109 21.6 0.68 19 1.42 6.4 214 106 Airflow MBh S/T ∆T kW 920 Amps HI PR LO PR MBh S/T ∆T kW 820 Amps HI PR LO PR MBh S/T ∆T 720 kW Amps HI PR LO PR 25.2 0.75 19 1.51 6.8 242 119 24.5 0.72 20 1.50 6.7 240 117 22.6 0.69 20 1.46 6.6 232 114 63 25.0 0.62 15 1.50 6.7 240 117 24.3 0.59 16 1.49 6.7 237 116 22.4 0.57 16 1.45 6.5 230 113 27.3 0.57 16 1.56 7.0 255 129 26.5 0.54 16 1.55 6.9 253 128 24.5 0.52 16 1.51 6.7 245 124 67 27.4 0.43 12 1.55 6.9 253 128 26.6 0.41 12 1.53 6.9 250 127 24.5 0.39 12 1.50 6.7 243 123 29.3 0.37 11 1.61 7.2 266 138 28.5 0.35 11 1.60 7.1 264 136 26.3 0.34 11 1.56 7.0 256 132 71 23.9 0.87 21 1.60 7.1 252 118 23.2 0.83 22 1.58 7.0 250 117 21.5 0.80 22 1.54 6.9 242 113 59 23.5 0.77 18 1.58 7.0 250 117 22.9 0.73 19 1.57 7.0 247 115 21.1 0.71 19 1.53 6.8 240 112 24.7 0.78 19 1.63 7.2 271 125 23.9 0.74 20 1.62 7.2 269 124 22.1 0.72 20 1.58 7.0 261 120 63 24.4 0.64 16 1.62 7.2 269 124 23.7 0.61 16 1.61 7.1 266 123 21.9 0.59 16 1.56 7.0 258 119 75 IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction access fittings. 75 70 IDB 65 26.7 0.59 16 1.69 7.5 287 137 25.9 0.56 16 1.67 7.4 284 135 23.9 0.54 17 1.63 7.2 275 131 67 26.7 0.44 12 1.67 7.4 284 135 26.0 0.42 12 1.66 7.3 281 134 24.0 0.41 12 1.62 7.2 273 130 28.6 0.38 11 1.74 7.7 299 146 27.8 0.36 11 1.73 7.6 296 144 25.7 0.35 11 1.69 7.5 287 140 71 23.4 0.89 21 1.70 7.6 287 122 22.7 0.85 22 1.69 7.6 284 121 20.9 0.82 22 1.64 7.4 276 118 59 23.0 0.79 18 1.69 7.6 284 121 22.3 0.75 19 1.67 7.5 281 120 20.6 0.72 19 1.63 7.3 273 116 24.1 0.80 19 1.74 7.8 309 130 23.4 0.76 20 1.73 7.7 306 129 21.6 0.74 20 1.68 7.5 297 125 26.0 0.61 16 1.80 8.0 326 142 25.3 0.58 16 1.78 8.0 323 141 23.3 0.56 17 1.74 7.8 313 136 22.8 0.92 21 1.79 8.1 327 129 22.1 0.88 22 1.78 8.0 324 127 20.4 0.85 22 1.73 7.8 314 123 23.5 0.83 19 1.84 8.3 352 137 22.8 0.79 20 1.82 8.2 348 135 21.0 0.76 20 1.77 8.0 338 131 25.4 0.62 16 1.90 8.5 371 149 24.7 0.60 16 1.88 8.4 368 148 22.8 0.57 17 1.83 8.2 357 143 27.3 0.40 11 1.96 8.8 387 159 26.5 0.38 11 1.95 8.7 383 157 24.4 0.37 12 1.90 8.5 372 153 71 21.7 0.96 21 1.87 8.6 368 135 21.0 0.91 22 1.86 8.5 364 133 19.4 0.88 22 1.81 8.3 353 129 59 21.3 0.84 18 1.86 8.5 364 133 20.7 0.80 19 1.84 8.4 360 132 19.1 0.78 19 1.79 8.2 350 128 22.3 0.86 19 1.92 8.7 396 143 21.7 0.82 20 1.90 8.7 392 142 20.0 0.79 20 1.85 8.5 380 138 63 22.1 0.70 16 1.90 8.7 392 142 21.4 0.67 16 1.88 8.6 388 140 19.8 0.65 16 1.83 8.4 376 136 24.1 0.65 16 1.98 9.0 418 156 23.4 0.62 16 1.96 8.9 414 155 21.6 0.60 16 1.91 8.7 401 150 67 24.2 0.49 12 1.96 8.9 414 155 23.5 0.47 12 1.95 8.9 409 153 21.7 0.45 12 1.90 8.6 397 149 105 25.9 0.42 11 2.05 9.3 436 167 25.2 0.40 11 2.03 9.2 431 165 23.2 0.38 11 1.98 9.0 418 160 71 20.1 0.97 19 1.94 9.0 406 139 19.5 0.92 20 1.92 8.9 402 138 18.0 0.89 20 1.87 8.7 390 134 59 19.7 0.85 17 1.92 8.9 402 138 19.2 0.81 17 1.91 8.9 398 137 17.7 0.78 18 1.86 8.6 386 132 20.7 0.86 18 1.99 9.2 437 148 20.1 0.82 19 1.97 9.1 433 147 18.5 0.79 19 1.92 8.9 420 142 63 20.5 0.71 15 1.97 9.1 433 147 19.9 0.68 15 1.95 9.1 428 145 18.3 0.65 15 1.90 8.8 416 141 22.4 0.65 15 2.05 9.5 462 162 21.7 0.62 15 2.04 9.4 457 160 20.0 0.60 15 1.98 9.2 443 155 67 22.4 0.49 11 2.04 9.4 457 160 21.8 0.47 11 2.02 9.3 452 159 20.1 0.45 12 1.97 9.1 439 154 115 24.0 0.42 10 2.13 9.8 481 172 23.3 0.40 10 2.11 9.7 477 171 21.5 0.39 11 2.05 9.5 462 166 71 - Shaded area reflects ACCA (TVA) conditions. kW = total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors) 28.0 0.39 11 1.86 8.3 340 151 27.1 0.37 11 1.85 8.2 337 150 25.1 0.36 11 1.80 8.0 327 145 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 23.8 26.1 22.4 23.2 25.5 0.66 0.46 0.81 0.68 0.47 16 12 18 16 12 1.73 1.78 1.78 1.82 1.88 7.7 8.0 8.0 8.2 8.4 306 323 323 348 368 129 141 127 135 148 23.1 25.3 21.8 22.6 24.7 0.63 0.43 0.77 0.65 0.45 16 12 19 16 12 1.71 1.77 1.76 1.80 1.87 7.7 7.9 8.0 8.1 8.4 303 320 320 345 364 128 139 126 134 146 21.3 23.4 20.1 20.8 22.8 0.60 0.42 0.75 0.62 0.43 16 13 19 17 13 1.67 1.72 1.72 1.76 1.82 7.5 7.7 7.8 7.9 8.2 294 310 311 334 353 124 135 122 130 142 Product Specifications Expanded Cooling Data — GPC1424H41** SS-GPC14H SS-GPC14H www.goodmanmfg.com 25.4 0.97 25 1.50 6.7 229 114 24.6 0.92 25 1.49 6.7 227 113 22.7 0.89 26 1.45 6.5 220 109 MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR 720 820 920 59 25.0 0.92 23 1.49 6.7 227 113 24.2 0.88 24 1.48 6.6 225 111 22.4 0.85 24 1.44 6.5 218 108 Airflow MBh S/T ∆T kW 920 Amps HI PR LO PR MBh S/T ∆T kW 820 Amps HI PR LO PR MBh S/T ∆T 720 kW Amps HI PR LO PR 25.9 0.93 24 1.54 6.9 247 121 25.1 0.89 25 1.52 6.8 244 120 23.2 0.86 25 1.49 6.7 237 116 63 25.5 0.87 22 1.52 6.8 244 120 24.8 0.83 23 1.51 6.8 242 119 22.8 0.80 23 1.47 6.6 235 115 27.1 0.84 23 1.59 7.1 261 132 26.3 0.80 24 1.57 7.0 258 131 24.3 0.77 24 1.53 6.9 250 127 67 27.2 0.70 19 1.57 7.0 258 131 26.4 0.67 20 1.56 7.0 256 129 24.4 0.65 20 1.52 6.8 248 126 28.9 0.68 20 1.64 7.3 272 141 28.1 0.65 21 1.63 7.2 269 139 25.9 0.63 21 1.59 7.1 261 135 71 29.1 0.53 15 1.63 7.2 269 139 28.3 0.50 16 1.61 7.2 267 138 26.1 0.48 16 1.57 7.0 259 134 24.8 1.00 25 1.62 7.2 257 120 24.1 0.96 26 1.61 7.2 255 119 22.2 0.92 26 1.57 7.0 247 115 59 24.4 0.96 23 1.61 7.2 255 119 23.7 0.91 24 1.60 7.1 252 118 21.8 0.88 25 1.56 6.9 245 114 25.3 0.97 24 1.66 7.4 277 128 24.5 0.92 25 1.65 7.3 274 127 22.6 0.89 26 1.60 7.1 266 123 63 24.9 0.90 22 1.65 7.3 274 127 24.2 0.86 23 1.63 7.2 272 125 22.3 0.82 24 1.59 7.1 263 122 75 IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction access fittings. 85 80 IDB 65 26.5 0.87 23 1.72 7.6 292 140 25.7 0.83 24 1.70 7.5 290 138 23.7 0.80 24 1.66 7.3 281 134 67 26.6 0.73 19 1.70 7.5 290 138 25.8 0.70 20 1.69 7.5 287 137 23.8 0.67 20 1.64 7.3 278 133 28.2 0.71 20 1.77 7.8 305 149 27.4 0.68 21 1.76 7.8 302 147 25.3 0.65 21 1.71 7.6 293 143 71 28.4 0.55 16 1.76 7.8 302 147 27.6 0.52 16 1.74 7.7 299 146 25.5 0.50 16 1.70 7.5 290 141 24.2 1.00 24 1.73 7.8 293 125 23.5 0.98 26 1.72 7.7 290 124 21.7 0.95 26 1.67 7.5 281 120 59 23.8 1.00 24 1.72 7.7 290 124 23.1 0.94 24 1.70 7.6 287 122 21.3 0.90 25 1.66 7.5 278 119 24.7 0.99 24 1.77 7.9 315 133 24.0 0.95 25 1.76 7.9 312 131 22.1 0.91 26 1.71 7.7 303 128 25.8 0.90 23 1.83 8.2 333 145 25.1 0.85 24 1.81 8.1 329 144 23.2 0.82 24 1.77 7.9 319 139 23.6 1.00 24 1.83 8.2 333 131 22.9 1.00 26 1.81 8.2 330 130 21.2 0.98 26 1.76 8.0 320 126 24.1 1.00 24 1.87 8.4 359 140 23.4 0.98 26 1.85 8.3 355 138 21.6 0.94 26 1.80 8.1 345 134 25.2 0.92 23 1.93 8.7 379 152 24.5 0.88 24 1.91 8.6 375 151 22.6 0.85 25 1.86 8.4 364 146 26.9 0.75 20 2.00 9.0 395 162 26.1 0.72 21 1.98 8.9 391 161 24.1 0.69 21 1.93 8.7 380 156 71 27.1 0.58 16 1.98 8.9 391 161 26.3 0.55 16 1.96 8.8 387 159 24.3 0.53 16 1.91 8.6 376 154 22.4 1.00 22 1.91 8.7 375 137 21.8 1.00 24 1.89 8.6 371 136 20.1 1.00 26 1.84 8.4 360 132 59 22.0 1.00 22 1.89 8.6 371 136 21.4 1.00 24 1.87 8.6 368 135 19.8 0.97 24 1.82 8.3 357 131 22.9 1.00 23 1.95 8.9 404 146 22.2 1.00 25 1.93 8.8 400 145 20.5 0.98 26 1.88 8.6 388 140 63 22.5 1.00 23 1.93 8.8 400 145 21.9 0.94 23 1.92 8.7 396 143 20.2 0.91 23 1.87 8.5 384 139 24.0 0.96 23 2.02 9.2 426 160 23.3 0.91 24 2.00 9.1 422 158 21.5 0.88 24 1.95 8.9 409 153 67 24.1 0.80 19 2.00 9.1 422 158 23.4 0.76 20 1.98 9.0 418 156 21.6 0.74 20 1.93 8.8 405 152 105 25.6 0.78 20 2.09 9.5 445 170 24.8 0.74 21 2.07 9.4 440 168 22.9 0.72 21 2.01 9.2 427 163 71 25.7 0.60 15 2.07 9.4 440 168 25.0 0.57 16 2.05 9.3 436 167 23.1 0.55 16 2.00 9.1 423 162 20.8 1.00 21 1.97 9.2 414 142 20.2 1.00 23 1.96 9.1 410 141 18.6 1.00 24 1.91 8.9 398 137 59 20.4 1.00 20 1.96 9.1 410 141 19.8 1.00 22 1.94 9.0 406 139 18.3 0.97 23 1.89 8.8 394 135 21.2 1.00 21 2.02 9.4 446 151 20.6 1.00 23 2.00 9.3 442 150 19.0 0.99 24 1.95 9.1 428 145 63 20.9 1.00 21 2.00 9.3 442 150 20.3 0.95 22 1.99 9.2 437 148 18.7 0.91 22 1.93 9.0 424 144 22.2 0.97 21 2.09 9.7 471 165 21.5 0.92 22 2.07 9.6 466 163 19.9 0.89 23 2.02 9.3 452 159 67 22.3 0.81 18 2.07 9.6 466 163 21.6 0.77 19 2.05 9.5 462 162 20.0 0.74 19 2.00 9.3 448 157 115 23.7 0.78 19 2.16 10.0 491 176 23.0 0.75 19 2.15 9.9 486 174 21.2 0.72 20 2.09 9.7 472 169 71 23.8 0.60 14 2.15 9.9 486 174 23.1 0.58 15 2.13 9.8 482 172 21.4 0.56 15 2.07 9.6 467 167 Shaded area reflects AHRI (TVA) conditions. kW = total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors) 27.6 0.73 20 1.89 8.4 347 154 26.8 0.69 21 1.88 8.4 344 153 24.7 0.67 21 1.83 8.2 333 148 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 24.3 26.0 27.8 23.2 23.7 25.3 0.92 0.75 0.56 1.00 0.95 0.77 22 19 16 23 23 20 1.76 1.81 1.88 1.81 1.85 1.91 7.9 8.1 8.4 8.2 8.3 8.6 312 329 344 330 355 375 131 144 153 130 138 151 23.6 25.2 27.0 22.5 23.0 24.6 0.88 0.71 0.53 0.97 0.91 0.74 23 20 16 24 23 20 1.74 1.80 1.86 1.79 1.84 1.90 7.8 8.0 8.3 8.1 8.3 8.5 309 326 340 327 352 371 130 142 151 129 137 149 21.8 23.3 24.9 20.8 21.3 22.7 0.85 0.69 0.51 0.93 0.87 0.71 24 20 16 25 24 21 1.70 1.75 1.81 1.75 1.79 1.85 7.6 7.8 8.1 7.9 8.1 8.3 300 316 330 317 341 360 126 138 147 125 133 145 Product Specifications Expanded Cooling Data — GPC1424H41** (cont.) 7 8 www.goodmanmfg.com 28.3 0.84 19 1.76 8.0 237 109 27.5 0.80 20 1.75 7.9 234 108 26.1 0.77 21 1.72 7.8 230 106 MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR 900 1020 1145 59 27.8 0.74 17 1.75 7.9 234 108 27.0 0.71 17 1.73 7.9 232 107 25.7 0.68 18 1.70 7.7 227 105 Airflow MBh S/T ∆T kW 1145 Amps HI PR LO PR MBh S/T ∆T kW 1020 Amps HI PR LO PR MBh S/T ∆T 900 kW Amps HI PR LO PR 29.1 0.75 18 1.80 8.1 255 116 28.3 0.72 18 1.79 8.1 252 115 26.9 0.69 19 1.76 8.0 247 112 63 28.8 0.62 14 1.78 8.1 252 115 28.0 0.59 15 1.77 8.0 250 114 26.6 0.57 15 1.74 7.9 245 111 31.5 0.57 14 1.86 8.4 269 127 30.6 0.54 15 1.84 8.3 266 125 29.1 0.52 15 1.81 8.2 261 123 67 31.6 0.43 11 1.84 8.3 266 125 30.7 0.41 11 1.83 8.2 264 124 29.1 0.39 12 1.80 8.1 258 122 33.9 0.37 10 1.92 8.6 281 135 32.9 0.35 10 1.90 8.6 278 133 31.2 0.34 11 1.87 8.4 272 131 71 27.6 0.87 19 1.90 8.5 266 115 26.8 0.83 20 1.89 8.5 263 114 25.5 0.80 21 1.85 8.3 258 112 59 27.2 0.77 17 1.89 8.5 263 114 26.4 0.73 17 1.87 8.4 260 113 25.1 0.70 18 1.84 8.3 255 111 28.5 0.78 18 1.94 8.7 286 122 27.6 0.74 19 1.93 8.6 283 121 26.3 0.71 19 1.90 8.5 277 119 63 28.2 0.64 15 1.93 8.6 283 121 27.4 0.61 15 1.91 8.6 280 120 26.0 0.59 16 1.88 8.4 275 118 75 IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction access fittings. 75 70 IDB 65 30.8 0.59 15 2.01 9.0 302 134 29.9 0.56 15 1.99 8.9 299 132 28.4 0.54 16 1.96 8.7 293 130 67 30.9 0.44 11 1.99 8.9 299 132 30.0 0.42 11 1.97 8.8 296 131 28.5 0.41 12 1.94 8.7 290 128 33.1 0.38 10 2.08 9.2 315 142 32.1 0.36 10 2.06 9.2 312 141 30.5 0.35 11 2.02 9.0 305 138 71 27.0 0.90 19 2.03 9.2 302 120 26.2 0.85 20 2.01 9.1 299 118 24.9 0.82 21 1.97 8.9 293 116 59 26.5 0.79 17 2.01 9.1 299 118 25.8 0.75 17 1.99 9.0 296 117 24.5 0.72 18 1.96 8.9 290 115 27.8 0.80 18 2.07 9.4 325 127 27.0 0.76 19 2.05 9.3 322 126 25.6 0.73 19 2.02 9.1 315 124 30.1 0.61 15 2.14 9.6 343 139 29.2 0.58 15 2.12 9.5 340 138 27.7 0.55 16 2.09 9.4 333 135 26.3 0.92 20 2.14 9.7 344 126 25.6 0.88 20 2.12 9.6 341 124 24.3 0.84 21 2.08 9.5 334 122 27.1 0.83 18 2.18 9.9 370 134 26.3 0.79 19 2.17 9.8 367 132 25.0 0.76 19 2.13 9.7 359 130 29.3 0.63 15 2.26 10.2 391 146 28.5 0.60 15 2.24 10.1 387 145 27.1 0.57 16 2.20 10.0 379 142 31.5 0.40 10 2.34 10.5 408 155 30.6 0.38 11 2.32 10.5 404 154 29.0 0.37 11 2.28 10.3 396 151 71 25.0 0.96 19 2.23 10.2 387 132 24.3 0.91 20 2.21 10.2 383 130 23.1 0.88 21 2.17 10.0 376 128 59 24.6 0.84 17 2.21 10.2 383 130 23.9 0.80 17 2.19 10.1 379 129 22.7 0.77 18 2.15 9.9 372 127 25.8 0.86 18 2.28 10.5 417 140 25.0 0.82 18 2.26 10.4 412 139 23.8 0.78 19 2.22 10.2 404 136 63 25.5 0.70 14 2.26 10.4 412 139 24.7 0.67 15 2.24 10.3 408 137 23.5 0.64 15 2.20 10.1 400 135 27.9 0.65 15 2.36 10.8 440 153 27.1 0.62 15 2.34 10.7 435 151 25.7 0.59 16 2.30 10.5 427 148 67 27.9 0.49 11 2.34 10.7 435 151 27.1 0.47 11 2.32 10.6 431 150 25.8 0.45 12 2.28 10.4 422 147 105 29.9 0.42 10 2.44 11.1 459 163 29.0 0.40 10 2.42 11.0 454 161 27.6 0.38 11 2.38 10.9 445 158 71 23.2 0.97 18 2.31 10.8 428 136 22.5 0.92 19 2.29 10.7 423 135 21.4 0.88 19 2.25 10.5 415 132 59 22.8 0.85 16 2.29 10.7 423 135 22.1 0.81 16 2.27 10.6 419 134 21.0 0.78 17 2.23 10.4 411 131 23.9 0.87 17 2.36 11.0 460 145 23.2 0.83 17 2.34 10.9 456 144 22.0 0.79 18 2.30 10.7 447 141 63 23.6 0.71 13 2.34 10.9 456 143 22.9 0.68 14 2.32 10.8 451 142 21.8 0.65 14 2.28 10.7 442 139 25.8 0.65 14 2.44 11.3 486 158 25.1 0.62 14 2.42 11.3 481 157 23.8 0.60 15 2.38 11.1 472 154 67 25.9 0.49 10 2.42 11.3 481 157 25.1 0.47 11 2.40 11.2 476 155 23.9 0.45 11 2.36 11.0 467 152 115 27.7 0.42 9 2.53 11.7 507 169 26.9 0.40 10 2.51 11.6 502 167 25.6 0.38 10 2.46 11.4 492 164 71 - Shaded area reflects ACCA (TVA) conditions. kW = total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors) 32.3 0.39 10 2.21 9.9 358 148 31.3 0.37 11 2.20 9.9 354 147 29.8 0.36 11 2.16 9.7 347 144 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 27.5 30.1 25.9 26.8 29.4 0.66 0.46 0.81 0.68 0.47 15 11 17 15 11 2.05 2.12 2.12 2.16 2.24 9.3 9.5 9.6 9.8 10.1 322 340 341 367 387 126 138 124 132 145 26.7 29.3 25.1 26.1 28.5 0.63 0.43 0.78 0.65 0.45 15 11 18 15 12 2.04 2.10 2.10 2.15 2.22 9.2 9.5 9.5 9.8 10.0 319 336 337 363 383 125 136 123 131 143 25.4 27.8 23.9 24.7 27.1 0.60 0.42 0.74 0.62 0.43 16 12 18 16 12 2.00 2.07 2.06 2.11 2.18 9.1 9.3 9.4 9.6 9.9 312 330 330 356 376 122 133 121 128 140 Product Specifications Expanded Cooling Data — GPC1430H41** SS-GPC14H SS-GPC14H www.goodmanmfg.com 29.3 0.97 23 1.79 8.1 241 111 28.5 0.92 24 1.78 8.0 239 110 27.0 0.89 24 1.75 7.9 234 108 MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR 900 1020 1145 59 28.8 0.92 21 1.78 8.0 239 110 28.0 0.88 22 1.76 8.0 237 109 26.6 0.84 23 1.73 7.9 232 107 Airflow MBh S/T ∆T kW 1145 Amps HI PR LO PR MBh S/T ∆T kW 1020 Amps HI PR LO PR MBh S/T ∆T 900 kW Amps HI PR LO PR 29.9 0.93 22 1.83 8.3 260 118 29.0 0.89 23 1.81 8.2 257 117 27.6 0.85 24 1.78 8.1 252 115 63 29.4 0.87 20 1.81 8.2 257 117 28.6 0.83 21 1.80 8.1 255 116 27.1 0.79 22 1.77 8.0 250 114 31.3 0.84 21 1.89 8.5 274 129 30.4 0.80 22 1.87 8.4 272 128 28.9 0.77 23 1.84 8.3 266 125 67 31.4 0.71 18 1.87 8.4 272 128 30.5 0.67 19 1.86 8.4 269 127 29.0 0.64 19 1.83 8.2 264 124 33.4 0.68 18 1.95 8.8 286 138 32.4 0.65 19 1.94 8.7 283 136 30.8 0.63 20 1.90 8.6 278 133 71 33.6 0.53 14 1.94 8.7 283 136 32.6 0.50 15 1.92 8.6 281 135 31.0 0.48 15 1.89 8.5 275 132 28.6 1.00 23 1.93 8.7 271 117 27.8 0.96 24 1.92 8.6 268 116 26.4 0.92 25 1.89 8.5 263 114 59 28.1 0.96 22 1.92 8.6 268 116 27.3 0.91 22 1.90 8.5 266 115 25.9 0.87 23 1.87 8.4 260 113 29.2 0.97 23 1.98 8.8 292 125 28.3 0.92 24 1.96 8.8 289 124 26.9 0.89 24 1.93 8.6 283 121 63 28.7 0.90 21 1.96 8.8 289 124 27.9 0.86 22 1.94 8.7 286 123 26.5 0.82 22 1.91 8.6 280 120 75 IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction access fittings. 85 80 IDB 65 30.6 0.87 21 2.04 9.1 308 136 29.7 0.83 22 2.03 9.0 305 135 28.2 0.80 23 1.99 8.9 299 132 67 30.7 0.73 18 2.03 9.0 305 135 29.8 0.70 19 2.01 9.0 302 134 28.3 0.67 19 1.97 8.8 296 131 32.6 0.71 19 2.11 9.4 321 145 31.7 0.68 19 2.09 9.3 318 144 30.1 0.65 20 2.06 9.2 312 141 71 32.8 0.55 14 2.09 9.3 318 144 31.9 0.52 15 2.08 9.2 315 142 30.3 0.50 15 2.04 9.1 309 140 27.9 1.00 22 2.06 9.3 308 122 27.1 0.98 24 2.04 9.2 305 121 25.8 0.94 25 2.01 9.1 299 118 59 27.5 1.00 22 2.04 9.2 305 121 26.7 0.94 23 2.03 9.2 302 120 25.3 0.90 23 1.99 9.0 296 117 28.5 0.99 23 2.11 9.5 332 130 27.7 0.95 24 2.09 9.4 328 129 26.3 0.91 24 2.05 9.3 322 126 29.8 0.90 21 2.18 9.8 350 142 29.0 0.86 22 2.16 9.7 347 140 27.5 0.82 23 2.12 9.5 340 138 27.3 1.00 22 2.17 9.9 351 128 26.5 1.00 24 2.15 9.8 348 127 25.1 0.97 25 2.12 9.6 341 124 27.8 1.00 22 2.22 10.1 378 136 27.0 0.98 24 2.20 10.0 374 135 25.6 0.94 25 2.16 9.8 367 132 29.1 0.93 22 2.30 10.4 399 149 28.3 0.88 22 2.28 10.3 395 147 26.8 0.85 23 2.24 10.1 387 145 31.1 0.75 19 2.38 10.7 416 159 30.1 0.72 19 2.36 10.6 412 157 28.6 0.69 20 2.32 10.5 404 154 71 31.3 0.58 15 2.36 10.6 412 157 30.4 0.55 15 2.34 10.5 408 155 28.8 0.53 16 2.30 10.4 400 152 25.9 1.00 21 2.27 10.4 395 134 25.1 1.00 23 2.25 10.3 391 133 23.9 1.00 24 2.21 10.2 383 130 59 25.5 1.00 20 2.25 10.3 391 133 24.7 1.00 22 2.23 10.2 387 132 23.5 0.96 23 2.19 10.1 379 129 26.4 1.00 21 2.32 10.6 425 143 25.6 1.00 23 2.30 10.6 421 142 24.4 0.97 24 2.26 10.4 412 139 63 26.0 1.00 21 2.30 10.6 421 142 25.3 0.94 21 2.28 10.5 417 140 24.0 0.90 22 2.24 10.3 408 137 27.7 0.96 21 2.40 11.0 449 156 26.8 0.92 22 2.38 10.9 444 155 25.5 0.88 23 2.34 10.7 435 151 67 27.8 0.80 18 2.38 10.9 444 155 27.0 0.77 19 2.36 10.8 440 153 25.6 0.73 19 2.32 10.6 431 150 105 29.5 0.78 18 2.48 11.3 468 166 28.6 0.74 19 2.46 11.2 463 165 27.2 0.71 20 2.42 11.0 454 161 71 29.7 0.60 14 2.46 11.2 463 165 28.8 0.57 15 2.44 11.1 459 163 27.4 0.55 15 2.40 11.0 450 160 24.0 1.00 19 2.35 11.0 436 139 23.3 1.00 21 2.33 10.9 432 138 22.1 1.00 23 2.29 10.7 423 135 59 23.6 1.00 19 2.33 10.9 432 138 22.9 1.00 21 2.31 10.8 428 136 21.7 0.97 22 2.27 10.6 419 134 24.5 1.00 20 2.40 11.2 470 148 23.7 1.00 21 2.38 11.1 465 146 22.6 0.98 23 2.34 10.9 456 143 63 24.1 1.00 19 2.38 11.1 465 146 23.4 0.95 20 2.36 11.0 460 145 22.2 0.91 21 2.32 10.8 451 142 25.6 0.97 20 2.49 11.5 496 161 24.9 0.92 21 2.46 11.4 491 160 23.6 0.88 21 2.42 11.3 481 157 67 25.7 0.81 17 2.46 11.4 491 160 25.0 0.77 17 2.44 11.3 486 158 23.7 0.74 18 2.40 11.2 476 155 115 27.3 0.79 17 2.57 11.9 517 172 26.5 0.75 18 2.55 11.8 512 170 25.2 0.72 18 2.51 11.6 502 167 71 27.5 0.61 13 2.55 11.8 512 170 26.7 0.58 14 2.53 11.7 507 169 25.4 0.55 14 2.48 11.5 497 165 Shaded area reflects AHRI (TVA) conditions. kW = total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors) 31.8 0.73 19 2.25 10.1 365 151 30.9 0.69 19 2.23 10.0 362 150 29.4 0.66 20 2.19 9.9 354 147 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 28.1 30.0 32.1 26.8 27.4 29.3 0.92 0.75 0.56 1.00 0.95 0.77 21 18 14 22 21 18 2.09 2.16 2.23 2.15 2.20 2.28 9.4 9.7 10.0 9.8 10.0 10.3 328 347 362 348 374 395 129 140 150 127 135 147 27.2 29.1 31.1 26.0 26.6 28.4 0.88 0.71 0.53 0.97 0.91 0.74 22 19 15 23 22 19 2.07 2.14 2.21 2.14 2.18 2.26 9.4 9.6 9.9 9.7 9.9 10.2 325 343 358 344 370 391 127 139 148 126 134 146 25.9 27.7 29.6 24.7 25.3 27.0 0.84 0.68 0.51 0.93 0.87 0.71 22 19 15 23 22 19 2.04 2.10 2.18 2.10 2.15 2.22 9.2 9.5 9.8 9.5 9.8 10.0 319 336 351 337 363 383 125 136 145 123 131 143 Product Specifications Expanded Cooling Data — GPC1430H41** (cont.) 9 10 www.goodmanmfg.com 36.4 0.84 21 2.39 10.3 238 111 35.4 0.81 22 2.37 10.3 236 110 32.7 0.78 22 2.32 10.0 229 107 MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR 1052 1201 1350 59 35.8 0.74 18 2.37 10.3 236 110 34.8 0.71 19 2.35 10.2 234 109 32.1 0.68 19 2.30 9.9 227 106 Airflow MBh S/T ∆T kW 1350 Amps HI PR LO PR MBh S/T ∆T kW 1201 Amps HI PR LO PR MBh S/T ∆T 1052 kW Amps HI PR LO PR 37.5 0.76 19 2.44 10.5 257 119 36.4 0.72 20 2.42 10.5 254 117 33.6 0.69 20 2.36 10.2 246 114 63 37.1 0.62 16 2.42 10.5 254 117 36.1 0.59 16 2.40 10.4 251 116 33.3 0.57 17 2.35 10.1 244 113 40.6 0.57 16 2.52 10.8 271 129 39.4 0.55 16 2.50 10.8 268 128 36.4 0.53 17 2.44 10.5 260 124 67 40.7 0.43 12 2.50 10.8 268 128 39.5 0.41 12 2.48 10.7 266 127 36.5 0.40 13 2.42 10.4 258 123 43.6 0.37 11 2.60 11.2 283 138 42.3 0.35 11 2.58 11.1 280 137 39.1 0.34 12 2.52 10.8 271 132 71 35.6 0.88 21 2.58 11.1 268 118 34.6 0.84 22 2.56 11.0 265 117 31.9 0.81 22 2.49 10.7 257 113 59 35.0 0.77 18 2.56 11.0 265 117 34.0 0.73 19 2.54 10.9 262 115 31.4 0.71 19 2.47 10.6 254 112 36.7 0.78 20 2.63 11.3 288 125 35.6 0.75 20 2.61 11.2 285 124 32.8 0.72 21 2.55 10.9 276 120 63 36.3 0.64 16 2.61 11.2 285 124 35.2 0.61 17 2.59 11.1 282 123 32.5 0.59 17 2.53 10.8 274 119 75 IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction access fittings. 75 70 IDB 65 39.7 0.59 16 2.72 11.6 304 137 38.5 0.57 17 2.70 11.5 301 135 35.6 0.55 17 2.63 11.2 292 131 67 39.8 0.45 12 2.70 11.5 301 135 38.6 0.43 13 2.67 11.4 298 134 35.6 0.41 13 2.61 11.2 289 130 42.6 0.38 11 2.81 12.0 317 146 41.3 0.36 12 2.79 11.9 314 144 38.2 0.35 12 2.72 11.6 304 140 71 34.7 0.90 21 2.74 11.9 304 122 33.7 0.86 22 2.72 11.8 301 121 31.1 0.83 22 2.65 11.5 292 118 59 34.2 0.79 18 2.72 11.8 301 121 33.2 0.75 19 2.70 11.7 298 120 30.6 0.73 19 2.63 11.4 289 116 35.8 0.80 20 2.80 12.1 327 130 34.7 0.77 20 2.78 12.0 324 129 32.1 0.74 21 2.71 11.8 314 125 38.7 0.61 16 2.89 12.5 346 142 37.6 0.58 17 2.87 12.4 342 141 34.7 0.56 17 2.80 12.1 332 137 33.9 0.93 21 2.89 12.6 347 129 32.9 0.88 22 2.86 12.5 343 127 30.4 0.85 23 2.79 12.2 333 123 34.9 0.83 20 2.95 12.9 373 137 33.9 0.79 21 2.93 12.8 369 135 31.3 0.76 21 2.85 12.5 358 131 37.8 0.63 16 3.05 13.3 394 149 36.7 0.60 17 3.02 13.2 390 148 33.9 0.58 17 2.95 12.8 378 143 40.6 0.40 11 3.15 13.7 411 159 39.4 0.38 12 3.12 13.6 407 157 36.3 0.37 12 3.05 13.3 394 153 71 32.2 0.96 21 3.01 13.3 390 135 31.3 0.92 22 2.98 13.2 386 133 28.9 0.88 22 2.91 12.9 374 129 59 31.7 0.85 18 2.98 13.2 386 133 30.7 0.81 19 2.96 13.1 382 132 28.4 0.78 19 2.88 12.8 371 128 33.2 0.86 19 3.08 13.6 420 143 32.2 0.82 20 3.05 13.5 415 142 29.7 0.79 21 2.97 13.2 403 138 63 32.8 0.71 16 3.05 13.5 415 142 31.9 0.67 16 3.02 13.4 411 141 29.4 0.65 17 2.95 13.1 399 136 35.9 0.65 16 3.18 14.0 443 157 34.8 0.62 17 3.15 13.9 439 155 32.2 0.60 17 3.07 13.6 425 150 67 36.0 0.49 12 3.15 13.9 439 155 34.9 0.47 12 3.13 13.8 434 153 32.2 0.45 13 3.05 13.5 421 149 105 38.5 0.42 11 3.29 14.5 462 167 37.4 0.40 11 3.26 14.4 457 165 34.5 0.39 12 3.18 14.0 444 160 71 29.8 0.97 20 3.12 14.0 431 139 29.0 0.93 21 3.09 13.9 426 138 26.7 0.89 21 3.01 13.6 414 134 59 29.3 0.85 17 3.09 13.9 426 138 28.5 0.81 18 3.06 13.8 422 137 26.3 0.78 18 2.98 13.5 409 133 30.7 0.87 18 3.19 14.4 464 148 29.8 0.83 19 3.16 14.2 459 147 27.5 0.80 19 3.08 13.9 445 142 63 30.4 0.71 15 3.16 14.2 459 147 29.5 0.68 15 3.13 14.1 454 145 27.2 0.66 16 3.05 13.8 441 141 33.2 0.66 15 3.29 14.8 489 162 32.3 0.63 15 3.27 14.7 485 160 29.8 0.60 16 3.18 14.3 470 155 67 33.3 0.49 11 3.26 14.7 485 160 32.3 0.47 12 3.24 14.5 480 159 29.9 0.45 12 3.15 14.2 465 154 115 35.7 0.42 10 3.41 15.3 510 172 34.6 0.40 11 3.38 15.2 505 171 32.0 0.39 11 3.29 14.8 490 166 71 - Shaded area reflects ACCA (TVA) conditions. kW = total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors) 41.6 0.39 11 2.99 12.9 361 151 40.4 0.37 12 2.97 12.8 357 150 37.2 0.36 12 2.89 12.5 346 145 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 35.4 38.8 33.3 34.6 37.9 0.66 0.46 0.82 0.68 0.47 16 12 19 16 12 2.78 2.87 2.86 2.93 3.02 12.0 12.4 12.5 12.8 13.2 324 342 343 369 390 129 141 127 135 148 34.4 37.7 32.4 33.5 36.8 0.63 0.44 0.78 0.65 0.45 17 13 19 17 13 2.76 2.85 2.84 2.90 3.00 11.9 12.3 12.4 12.7 13.1 321 339 340 365 386 128 139 126 134 146 31.7 34.8 29.9 31.0 33.9 0.61 0.42 0.75 0.63 0.43 17 13 20 17 13 2.69 2.77 2.77 2.83 2.92 11.7 12.0 12.1 12.4 12.7 311 329 329 355 374 124 135 122 130 142 Product Specifications Expanded Cooling Data — GPC1436H41** SS-GPC14H SS-GPC14H www.goodmanmfg.com 37.7 0.97 25 2.43 10.5 243 114 36.6 0.93 26 2.41 10.4 241 113 33.8 0.89 26 2.35 10.2 234 109 MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR 1052 1201 1350 59 37.1 0.93 23 2.41 10.4 241 113 36.0 0.88 24 2.39 10.3 238 111 33.2 0.85 25 2.33 10.1 231 108 Airflow MBh S/T ∆T kW 1350 Amps HI PR LO PR MBh S/T ∆T kW 1201 Amps HI PR LO PR MBh S/T ∆T 1052 kW Amps HI PR LO PR 38.5 0.94 25 2.48 10.7 262 121 37.4 0.89 26 2.46 10.6 259 120 34.5 0.86 26 2.40 10.4 251 116 63 37.9 0.87 22 2.46 10.6 259 120 36.8 0.83 23 2.44 10.6 257 119 34.0 0.80 24 2.38 10.3 249 115 40.3 0.85 23 2.56 11.0 276 132 39.1 0.81 24 2.54 10.9 274 131 36.1 0.78 25 2.48 10.7 265 127 67 40.5 0.71 20 2.54 10.9 274 131 39.3 0.67 20 2.52 10.8 271 129 36.3 0.65 21 2.46 10.6 263 126 43.0 0.69 20 2.65 11.4 288 141 41.7 0.65 21 2.62 11.3 285 139 38.5 0.63 21 2.56 11.0 277 135 71 43.3 0.53 16 2.62 11.3 285 139 42.0 0.50 16 2.60 11.2 283 138 38.8 0.49 16 2.54 10.9 274 134 36.9 1.00 25 2.62 11.2 273 120 35.8 0.96 26 2.60 11.1 270 119 33.0 0.93 27 2.53 10.9 262 115 59 36.2 0.96 24 2.60 11.1 270 119 35.2 0.92 25 2.58 11.1 268 118 32.5 0.88 25 2.51 10.8 260 114 37.6 0.97 25 2.68 11.5 294 128 36.5 0.93 26 2.65 11.4 291 127 33.7 0.89 26 2.59 11.1 282 123 63 37.0 0.90 23 2.65 11.4 291 127 35.9 0.86 24 2.63 11.3 288 125 33.2 0.83 24 2.57 11.0 279 122 75 IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction access fittings. 85 80 IDB 65 39.4 0.88 24 2.76 11.8 310 140 38.2 0.84 24 2.74 11.7 307 138 35.3 0.81 25 2.67 11.4 298 134 67 39.6 0.73 20 2.74 11.7 307 138 38.4 0.70 21 2.72 11.6 304 137 35.4 0.67 21 2.65 11.3 295 133 42.0 0.71 20 2.86 12.2 323 149 40.8 0.68 21 2.83 12.1 320 147 37.6 0.65 21 2.76 11.8 311 143 71 42.3 0.55 16 2.83 12.1 320 147 41.1 0.52 16 2.81 12.0 317 146 37.9 0.50 17 2.74 11.7 308 141 36.0 1.00 25 2.79 12.1 310 125 34.9 0.98 26 2.76 12.0 307 124 32.2 0.95 27 2.70 11.7 298 120 59 35.4 1.00 24 2.76 12.0 307 124 34.3 0.94 25 2.74 11.9 304 122 31.7 0.91 25 2.67 11.6 295 119 36.7 1.00 25 2.85 12.3 334 133 35.6 0.95 26 2.83 12.2 331 132 32.9 0.92 26 2.75 11.9 321 128 38.4 0.90 24 2.94 12.7 353 145 37.3 0.86 24 2.92 12.6 349 144 34.4 0.83 25 2.84 12.3 339 139 35.1 1.00 24 2.93 12.8 354 131 34.1 1.00 26 2.91 12.7 350 130 31.5 0.98 27 2.84 12.4 340 126 35.8 1.00 24 3.00 13.1 380 140 34.7 0.98 26 2.98 13.0 377 138 32.1 0.95 26 2.90 12.7 365 134 37.5 0.93 24 3.10 13.5 402 152 36.4 0.89 25 3.07 13.4 398 151 33.6 0.85 25 3.00 13.0 386 146 40.0 0.75 21 3.21 13.9 419 162 38.8 0.72 21 3.18 13.8 415 161 35.8 0.69 22 3.10 13.5 402 156 71 40.3 0.58 16 3.18 13.8 415 161 39.1 0.55 17 3.15 13.7 411 159 36.1 0.53 17 3.07 13.4 398 154 33.4 1.00 23 3.06 13.6 398 137 32.4 1.00 25 3.03 13.4 394 136 29.9 1.00 26 2.96 13.1 382 132 59 32.8 1.00 22 3.03 13.4 394 136 31.8 1.00 24 3.01 13.3 390 135 29.4 0.97 25 2.93 13.0 378 131 34.0 1.00 23 3.13 13.9 428 146 33.0 1.00 25 3.10 13.7 424 145 30.5 0.98 26 3.02 13.4 411 140 63 33.5 1.00 23 3.10 13.7 424 145 32.5 0.94 23 3.08 13.6 420 143 30.0 0.91 24 3.00 13.3 407 139 35.6 0.96 23 3.23 14.3 452 160 34.6 0.92 24 3.21 14.2 447 158 31.9 0.89 25 3.12 13.8 434 153 67 35.8 0.81 20 3.21 14.2 447 158 34.7 0.77 20 3.18 14.0 443 157 32.1 0.74 21 3.10 13.7 430 152 105 38.0 0.78 20 3.34 14.8 471 170 36.9 0.75 21 3.32 14.6 467 168 34.0 0.72 21 3.23 14.3 453 163 71 38.3 0.60 16 3.32 14.6 467 168 37.1 0.57 16 3.29 14.5 462 167 34.3 0.55 17 3.20 14.2 448 162 30.9 1.00 21 3.17 14.3 439 142 30.0 1.00 23 3.14 14.2 435 141 27.7 1.00 24 3.06 13.8 422 137 59 30.4 1.00 21 3.14 14.2 435 141 29.5 1.00 23 3.12 14.0 431 139 27.2 0.98 23 3.04 13.7 418 135 31.5 1.00 21 3.24 14.6 473 151 30.6 1.00 23 3.21 14.5 468 150 28.2 0.99 24 3.13 14.1 454 145 63 31.0 1.00 21 3.21 14.5 468 150 30.1 0.95 22 3.19 14.4 464 148 27.8 0.92 22 3.10 14.0 450 144 33.0 0.97 22 3.35 15.0 499 165 32.0 0.93 23 3.32 14.9 494 164 29.6 0.89 23 3.24 14.5 480 159 67 33.1 0.81 18 3.32 14.9 494 164 32.2 0.77 19 3.29 14.8 489 162 29.7 0.75 19 3.21 14.4 475 157 115 35.2 0.79 19 3.47 15.6 521 176 34.2 0.75 20 3.44 15.4 516 174 31.5 0.72 20 3.35 15.0 500 169 71 35.4 0.61 15 3.44 15.4 516 174 34.4 0.58 15 3.41 15.3 511 172 31.8 0.56 15 3.32 14.9 495 167 Shaded area reflects AHRI (TVA) conditions. kW = total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors) 41.0 0.73 20 3.04 13.1 368 154 39.8 0.70 21 3.02 13.0 364 153 36.7 0.67 22 2.94 12.7 353 148 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 36.1 38.6 41.3 34.5 35.3 37.7 0.92 0.75 0.56 1.00 0.95 0.78 23 20 16 24 23 20 2.83 2.92 3.02 2.91 2.98 3.07 12.2 12.6 13.0 12.7 13.0 13.4 331 349 364 350 377 398 132 144 153 130 138 151 35.1 37.5 40.1 33.5 34.2 36.6 0.88 0.72 0.54 0.97 0.91 0.74 24 21 16 25 24 21 2.80 2.89 2.99 2.89 2.95 3.05 12.1 12.5 12.9 12.6 12.9 13.3 327 346 361 347 373 394 130 142 151 129 137 149 32.4 34.6 37.0 30.9 31.6 33.8 0.85 0.69 0.52 0.93 0.88 0.71 24 21 17 25 24 21 2.73 2.82 2.92 2.81 2.88 2.97 11.9 12.2 12.6 12.3 12.6 12.9 318 335 350 336 362 382 126 138 147 125 133 145 Product Specifications Expanded Cooling Data — GPC1436H41** (cont.) 11 12 www.goodmanmfg.com 40.5 0.82 21 2.70 11.5 244 110 39.3 0.78 22 2.68 11.4 241 109 36.3 0.75 23 2.62 11.1 234 106 MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR 1116 1274 1432 59 39.8 0.72 18 2.68 11.4 241 109 38.6 0.69 19 2.66 11.3 239 108 35.7 0.66 20 2.60 11.0 232 105 Airflow MBh S/T ∆T kW 1432 Amps HI PR LO PR MBh S/T ∆T kW 1274 Amps HI PR LO PR MBh S/T ∆T 1116 kW Amps HI PR LO PR 41.7 0.73 20 2.76 11.8 262 117 40.5 0.70 20 2.74 11.7 260 116 37.3 0.68 21 2.67 11.4 252 112 63 41.3 0.60 16 2.74 11.7 260 116 40.1 0.58 17 2.72 11.6 257 115 37.0 0.55 17 2.65 11.3 249 111 45.1 0.56 16 2.85 12.2 277 128 43.8 0.53 17 2.82 12.0 274 127 40.4 0.51 17 2.76 11.7 266 123 67 45.2 0.42 12 2.82 12.0 274 127 43.9 0.40 13 2.80 11.9 272 125 40.5 0.38 13 2.73 11.6 263 122 48.4 0.36 11 2.94 12.6 289 136 47.0 0.34 12 2.91 12.5 286 135 43.4 0.33 12 2.84 12.1 277 131 71 39.5 0.85 22 2.91 12.4 274 116 38.4 0.81 22 2.89 12.3 271 115 35.4 0.78 23 2.82 12.0 263 112 59 38.9 0.75 19 2.89 12.3 271 115 37.7 0.71 19 2.86 12.2 268 114 34.8 0.69 20 2.79 11.9 260 111 40.7 0.76 20 2.97 12.7 294 124 39.5 0.73 21 2.95 12.6 291 123 36.5 0.70 21 2.88 12.3 283 119 63 40.3 0.63 16 2.95 12.6 291 122 39.1 0.60 17 2.92 12.5 289 121 36.1 0.57 17 2.85 12.2 280 118 75 IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction access fittings. 75 70 IDB 65 44.1 0.58 16 3.07 13.1 311 135 42.8 0.55 17 3.04 13.0 308 134 39.5 0.53 17 2.97 12.6 299 130 67 44.1 0.43 12 3.04 13.0 308 134 42.9 0.41 13 3.02 12.9 305 132 39.6 0.40 13 2.94 12.5 296 128 47.3 0.37 11 3.17 13.6 324 144 45.9 0.35 12 3.14 13.4 321 142 42.4 0.34 12 3.07 13.1 311 138 71 38.6 0.87 22 3.09 13.4 311 121 37.5 0.83 22 3.07 13.3 308 120 34.6 0.80 23 2.99 13.0 299 116 59 38.0 0.77 19 3.07 13.3 308 120 36.8 0.73 19 3.04 13.2 305 118 34.0 0.71 20 2.97 12.8 296 115 39.7 0.78 20 3.16 13.7 335 129 38.6 0.74 21 3.14 13.6 331 127 35.6 0.72 21 3.06 13.3 322 124 43.0 0.59 16 3.27 14.2 354 140 41.8 0.56 17 3.24 14.0 350 139 38.5 0.54 17 3.16 13.7 340 135 37.7 0.90 22 3.26 14.3 354 127 36.6 0.86 23 3.23 14.2 351 126 33.7 0.83 23 3.15 13.8 340 122 38.8 0.81 20 3.33 14.6 381 135 37.6 0.77 21 3.30 14.5 378 134 34.7 0.74 21 3.22 14.1 366 130 42.0 0.61 16 3.44 15.1 403 147 40.7 0.58 17 3.41 15.0 399 146 37.6 0.56 17 3.32 14.6 387 142 45.0 0.39 11 3.55 15.7 420 157 43.7 0.37 12 3.52 15.5 416 156 40.4 0.36 12 3.44 15.1 403 151 71 35.8 0.93 21 3.39 15.2 399 133 34.7 0.89 22 3.37 15.1 395 132 32.1 0.86 23 3.28 14.7 383 128 59 35.2 0.82 19 3.37 15.1 395 132 34.1 0.78 19 3.34 14.9 391 130 31.5 0.76 20 3.25 14.5 379 127 36.8 0.84 20 3.47 15.5 429 142 35.8 0.80 21 3.44 15.4 425 140 33.0 0.77 21 3.35 15.0 412 136 63 36.5 0.69 16 3.44 15.4 425 140 35.4 0.65 17 3.41 15.3 420 139 32.7 0.63 17 3.33 14.9 408 135 39.9 0.63 16 3.59 16.0 453 155 38.7 0.60 17 3.56 15.9 449 153 35.7 0.58 17 3.47 15.5 435 148 67 39.9 0.48 12 3.56 15.9 448 153 38.8 0.45 13 3.53 15.8 444 151 35.8 0.44 13 3.44 15.3 431 147 105 42.8 0.41 11 3.71 16.6 472 165 41.5 0.39 12 3.68 16.5 468 163 38.3 0.37 12 3.58 16.0 454 158 71 33.1 0.94 20 3.51 16.1 440 138 32.2 0.90 21 3.48 15.9 436 136 29.7 0.87 21 3.40 15.5 423 132 59 32.6 0.83 17 3.48 15.9 436 136 31.6 0.79 18 3.45 15.8 432 135 29.2 0.76 18 3.37 15.3 419 131 34.1 0.84 18 3.59 16.4 474 146 33.1 0.80 19 3.56 16.3 469 145 30.6 0.78 20 3.47 15.9 455 141 63 33.8 0.69 15 3.56 16.3 469 145 32.8 0.66 16 3.53 16.1 465 144 30.3 0.64 16 3.44 15.7 451 139 36.9 0.64 15 3.71 17.0 501 160 35.9 0.61 16 3.68 16.8 496 158 33.1 0.59 16 3.59 16.4 481 154 67 37.0 0.48 11 3.68 16.8 495 158 35.9 0.46 12 3.65 16.7 491 157 33.2 0.44 12 3.56 16.2 476 152 115 39.6 0.41 10 3.84 17.6 522 170 38.5 0.39 11 3.81 17.4 517 169 35.5 0.38 11 3.71 17.0 501 164 71 - Shaded area reflects ACCA (TVA) conditions. kW = total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors) 46.2 0.38 11 3.37 14.7 369 150 44.8 0.36 12 3.35 14.6 365 148 41.4 0.35 12 3.26 14.2 354 144 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 39.3 43.1 37.0 38.4 42.0 0.64 0.44 0.79 0.66 0.46 16 12 19 16 12 3.14 3.24 3.23 3.30 3.41 13.6 14.0 14.2 14.5 15.0 331 350 351 377 399 127 139 126 134 146 38.2 41.8 35.9 37.3 40.8 0.61 0.42 0.76 0.63 0.44 17 13 20 17 13 3.11 3.21 3.20 3.27 3.38 13.5 13.9 14.1 14.4 14.8 328 346 347 374 395 126 138 124 132 145 35.2 38.6 33.2 34.4 37.7 0.59 0.41 0.73 0.61 0.42 17 13 20 17 13 3.03 3.13 3.12 3.19 3.30 13.1 13.6 13.7 14.0 14.4 318 336 337 363 383 122 133 121 128 140 Product Specifications Expanded Cooling Data — GPC1442H41** SS-GPC14H SS-GPC14H www.goodmanmfg.com 41.9 0.94 25 2.75 11.7 249 112 40.7 0.90 26 2.72 11.6 246 111 37.6 0.87 27 2.66 11.3 239 108 MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR 1116 1274 1432 59 41.2 0.90 24 2.72 11.6 246 111 40.0 0.86 25 2.70 11.5 244 110 36.9 0.83 25 2.64 11.2 236 107 Airflow MBh S/T ∆T kW 1432 Amps HI PR LO PR MBh S/T ∆T kW 1274 Amps HI PR LO PR MBh S/T ∆T 1116 kW Amps HI PR LO PR 42.7 0.91 25 2.80 12.0 268 119 41.5 0.87 26 2.78 11.9 265 118 38.3 0.84 26 2.71 11.6 257 115 63 42.1 0.84 23 2.78 11.9 265 118 40.9 0.81 24 2.76 11.8 262 117 37.7 0.78 24 2.69 11.5 255 114 44.7 0.82 24 2.89 12.4 283 130 43.4 0.78 25 2.87 12.3 280 129 40.1 0.76 25 2.80 11.9 271 125 67 45.0 0.69 20 2.87 12.3 280 129 43.7 0.66 21 2.85 12.2 277 128 40.3 0.63 21 2.78 11.8 269 124 47.7 0.67 20 2.99 12.8 295 139 46.3 0.64 21 2.96 12.7 292 138 42.8 0.61 22 2.89 12.4 283 133 71 48.1 0.51 16 2.96 12.7 292 138 46.7 0.49 17 2.94 12.6 289 136 43.1 0.47 17 2.87 12.3 280 132 40.9 0.98 26 2.96 12.6 279 119 39.7 0.93 27 2.93 12.5 276 117 36.7 0.90 27 2.86 12.2 268 114 59 40.2 0.93 24 2.93 12.5 276 117 39.1 0.89 25 2.91 12.4 274 116 36.1 0.86 25 2.84 12.1 265 113 41.7 0.94 25 3.02 12.9 300 126 40.5 0.90 26 3.00 12.8 297 125 37.4 0.87 27 2.92 12.5 288 121 63 41.1 0.88 23 3.00 12.8 297 125 39.9 0.83 24 2.97 12.7 294 124 36.8 0.80 24 2.90 12.4 286 120 75 IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction access fittings. 85 80 IDB 65 43.7 0.85 24 3.12 13.3 317 138 42.4 0.81 25 3.09 13.2 314 136 39.2 0.78 25 3.02 12.9 305 132 67 43.9 0.71 20 3.09 13.2 314 136 42.6 0.68 21 3.07 13.1 311 135 39.4 0.66 21 2.99 12.7 302 131 46.6 0.69 21 3.22 13.8 331 147 45.3 0.66 22 3.20 13.7 327 145 41.8 0.64 22 3.12 13.3 318 141 71 47.0 0.53 16 3.20 13.7 327 145 45.6 0.51 17 3.17 13.6 324 144 42.1 0.49 17 3.09 13.2 315 140 40.0 1.00 26 3.15 13.7 317 123 38.8 0.96 27 3.12 13.5 314 122 35.8 0.92 27 3.04 13.2 305 118 59 39.3 0.96 24 3.12 13.5 314 122 38.1 0.91 25 3.09 13.4 311 121 35.2 0.88 26 3.02 13.1 302 117 40.7 0.97 25 3.21 14.0 342 131 39.6 0.92 26 3.19 13.9 338 130 36.5 0.89 27 3.11 13.5 328 126 42.7 0.87 24 3.32 14.4 361 143 41.4 0.83 25 3.29 14.3 357 142 38.2 0.80 25 3.21 13.9 346 138 39.0 1.00 25 3.31 14.6 361 130 37.9 0.99 27 3.28 14.4 358 128 34.9 0.95 27 3.20 14.1 347 124 39.7 1.00 25 3.39 14.9 389 138 38.6 0.95 27 3.36 14.8 385 136 35.6 0.92 27 3.27 14.4 374 132 41.6 0.90 24 3.50 15.4 411 150 40.4 0.86 25 3.47 15.2 407 149 37.3 0.83 25 3.38 14.8 395 145 44.4 0.73 21 3.62 15.9 428 160 43.1 0.70 22 3.58 15.8 424 159 39.8 0.67 22 3.49 15.4 411 154 71 44.7 0.56 16 3.58 15.8 424 159 43.4 0.54 17 3.55 15.7 420 157 40.1 0.52 17 3.46 15.2 407 152 37.0 1.00 24 3.45 15.5 407 136 36.0 1.00 26 3.42 15.3 403 134 33.2 0.99 27 3.34 14.9 391 130 59 36.4 1.00 23 3.42 15.3 403 134 35.3 0.98 25 3.40 15.2 399 133 32.6 0.94 25 3.31 14.8 387 129 37.8 1.00 24 3.53 15.8 438 144 36.7 0.99 26 3.50 15.7 433 143 33.8 0.95 27 3.41 15.3 420 139 63 37.2 0.96 23 3.50 15.7 433 143 36.1 0.92 24 3.47 15.5 429 142 33.3 0.88 24 3.38 15.1 416 137 39.5 0.94 24 3.65 16.3 462 158 38.4 0.89 25 3.62 16.2 458 156 35.4 0.86 25 3.52 15.8 444 151 67 39.7 0.78 20 3.62 16.2 458 156 38.6 0.75 21 3.59 16.0 453 155 35.6 0.72 21 3.50 15.6 439 150 105 42.2 0.76 21 3.77 16.9 482 168 41.0 0.72 21 3.74 16.8 477 166 37.8 0.70 22 3.64 16.3 463 161 71 42.5 0.58 16 3.74 16.8 477 166 41.2 0.56 17 3.71 16.6 473 165 38.1 0.54 17 3.61 16.2 458 160 34.3 1.00 22 3.57 16.3 449 140 33.3 1.00 24 3.54 16.2 445 139 30.7 1.00 25 3.45 15.8 432 135 59 33.7 1.00 22 3.54 16.2 445 139 32.7 0.99 23 3.51 16.1 440 138 30.2 0.95 24 3.43 15.6 427 134 35.0 1.00 22 3.65 16.7 484 149 34.0 1.00 24 3.62 16.6 479 148 31.3 0.96 25 3.53 16.1 464 143 63 34.5 0.97 21 3.62 16.6 479 148 33.5 0.92 22 3.59 16.4 474 146 30.9 0.89 23 3.50 16.0 460 142 36.6 0.94 22 3.78 17.3 511 163 35.6 0.90 23 3.75 17.1 506 161 32.8 0.87 23 3.65 16.7 490 157 67 36.8 0.79 19 3.75 17.1 506 161 35.7 0.75 19 3.71 17.0 501 160 33.0 0.73 20 3.62 16.5 486 155 115 39.1 0.77 19 3.91 17.9 533 174 37.9 0.73 20 3.87 17.8 527 172 35.0 0.70 20 3.77 17.3 511 167 71 39.4 0.59 15 3.87 17.8 527 172 38.2 0.56 16 3.84 17.6 522 170 35.3 0.54 16 3.74 17.1 506 165 Shaded area reflects AHRI (TVA) conditions. kW = total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors) 45.5 0.71 21 3.43 14.9 376 153 44.2 0.68 22 3.40 14.8 372 151 40.8 0.65 22 3.32 14.4 361 147 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 40.1 42.9 45.8 38.3 39.2 41.8 0.90 0.73 0.55 1.00 0.93 0.75 23 20 16 25 23 20 3.19 3.29 3.40 3.28 3.36 3.47 13.9 14.3 14.8 14.4 14.8 15.2 338 357 372 358 385 407 130 142 151 128 136 149 39.0 41.6 44.5 37.2 38.0 40.6 0.86 0.70 0.52 0.94 0.88 0.72 24 21 17 25 24 21 3.16 3.27 3.37 3.26 3.33 3.44 13.7 14.2 14.7 14.3 14.6 15.1 335 354 369 354 381 403 129 140 150 127 135 148 36.0 38.4 41.1 34.3 35.1 37.5 0.83 0.67 0.50 0.91 0.85 0.69 24 21 17 26 25 21 3.08 3.18 3.29 3.18 3.25 3.35 13.4 13.8 14.3 13.9 14.3 14.7 325 343 358 344 370 391 125 136 145 123 131 143 Product Specifications Expanded Cooling Data — GPC1442H41** (cont.) 13 14 www.goodmanmfg.com 46.9 0.85 21 2.42 13.3 235 112 45.5 0.81 22 2.39 13.2 233 111 42.0 0.78 22 2.32 12.8 226 108 MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR 1386 1582 1777 59 46.1 0.75 18 2.39 13.2 232 111 44.8 0.72 19 2.37 13.1 230 110 41.3 0.69 19 2.30 12.7 223 106 Airflow MBh S/T ∆T kW 1777 Amps HI PR LO PR MBh S/T ∆T kW 1582 Amps HI PR LO PR MBh S/T ∆T 1386 kW Amps HI PR LO PR 48.3 0.76 19 2.48 13.5 253 119 46.9 0.73 20 2.46 13.4 250 118 43.3 0.70 20 2.38 13.1 243 114 63 47.8 0.63 15 2.46 13.4 250 118 46.4 0.60 16 2.43 13.3 248 117 42.8 0.58 16 2.36 13.0 240 113 52.3 0.58 16 2.58 13.9 267 130 50.8 0.55 16 2.56 13.8 264 129 46.8 0.53 17 2.48 13.5 256 125 67 52.4 0.43 12 2.55 13.8 264 129 50.9 0.41 12 2.53 13.7 262 127 46.9 0.40 12 2.45 13.4 254 124 56.1 0.37 11 2.68 14.4 278 138 54.5 0.35 11 2.66 14.3 276 137 50.3 0.34 11 2.58 13.9 267 133 71 45.8 0.88 21 2.65 14.2 263 118 44.5 0.84 22 2.63 14.1 261 117 41.1 0.81 22 2.55 13.8 253 114 59 45.1 0.78 18 2.63 14.1 261 117 43.7 0.74 19 2.60 14.0 258 116 40.4 0.72 19 2.52 13.6 251 112 47.2 0.79 19 2.72 14.5 284 126 45.8 0.75 20 2.70 14.4 281 125 42.3 0.73 20 2.62 14.1 272 121 63 46.7 0.65 16 2.70 14.4 281 125 45.3 0.62 16 2.67 14.3 278 123 41.8 0.60 17 2.59 13.9 270 120 75 IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction access fittings. 75 70 IDB 65 51.1 0.60 16 2.83 14.9 299 137 49.6 0.57 16 2.80 14.8 296 136 45.8 0.55 17 2.72 14.5 288 132 67 51.2 0.45 12 2.80 14.8 296 136 49.7 0.43 12 2.78 14.7 293 135 45.8 0.41 13 2.69 14.3 285 131 54.8 0.39 11 2.95 15.5 312 146 53.2 0.37 11 2.92 15.3 309 145 49.1 0.35 12 2.83 14.9 300 141 71 44.7 0.91 21 2.86 15.3 300 123 43.4 0.86 22 2.83 15.2 297 122 40.1 0.83 22 2.75 14.8 288 118 59 44.0 0.80 18 2.83 15.2 297 122 42.7 0.76 19 2.80 15.1 294 120 39.4 0.73 19 2.72 14.7 285 117 46.0 0.81 19 2.94 15.6 322 131 44.7 0.77 20 2.91 15.5 319 129 41.3 0.75 20 2.82 15.1 310 126 49.8 0.61 16 3.05 16.1 341 143 48.4 0.59 16 3.02 16.0 337 141 44.7 0.56 17 2.93 15.6 327 137 43.6 0.94 21 3.04 16.3 341 129 42.4 0.89 22 3.01 16.1 338 128 39.1 0.86 22 2.92 15.7 328 124 44.9 0.84 19 3.13 16.6 367 137 43.6 0.80 20 3.10 16.5 364 136 40.3 0.77 21 3.00 16.1 353 132 48.6 0.63 16 3.25 17.1 388 150 47.2 0.60 17 3.22 17.0 384 149 43.6 0.58 17 3.12 16.6 373 144 52.2 0.41 11 3.38 17.7 405 160 50.7 0.39 11 3.35 17.6 401 158 46.8 0.37 12 3.25 17.1 389 153 71 41.5 0.97 21 3.20 17.2 384 135 40.2 0.93 22 3.17 17.1 380 134 37.1 0.89 22 3.07 16.6 369 130 59 40.8 0.85 18 3.17 17.1 380 134 39.6 0.81 19 3.14 16.9 376 133 36.5 0.79 19 3.04 16.5 365 129 42.7 0.87 19 3.29 17.6 413 144 41.4 0.83 20 3.25 17.5 409 143 38.2 0.80 20 3.16 17.0 397 138 63 42.2 0.71 16 3.25 17.4 409 143 41.0 0.68 16 3.22 17.3 405 141 37.9 0.66 16 3.12 16.9 393 137 46.2 0.66 16 3.42 18.1 436 157 44.9 0.63 16 3.38 18.0 432 156 41.4 0.60 17 3.28 17.5 419 151 67 46.3 0.49 12 3.38 18.0 432 156 44.9 0.47 12 3.35 17.8 428 154 41.5 0.45 13 3.25 17.4 415 149 105 49.6 0.42 11 3.55 18.8 455 167 48.1 0.40 11 3.52 18.6 451 166 44.4 0.39 11 3.41 18.1 437 161 71 38.4 0.98 19 3.34 18.1 424 140 37.3 0.93 20 3.30 18.0 420 139 34.4 0.90 21 3.20 17.5 407 134 59 37.8 0.86 17 3.30 18.0 420 139 36.7 0.82 18 3.27 17.8 416 137 33.8 0.79 18 3.17 17.4 403 133 39.5 0.88 18 3.43 18.6 457 149 38.4 0.84 19 3.39 18.4 452 147 35.4 0.81 19 3.29 17.9 438 143 63 39.1 0.72 15 3.39 18.4 452 147 38.0 0.69 15 3.36 18.2 447 146 35.1 0.66 15 3.26 17.8 434 142 42.8 0.66 15 3.56 19.1 482 163 41.5 0.63 15 3.53 19.0 477 161 38.3 0.61 16 3.42 18.5 463 156 67 42.9 0.50 11 3.52 19.0 477 161 41.6 0.48 12 3.49 18.8 473 159 38.4 0.46 12 3.38 18.3 458 155 115 45.9 0.43 10 3.70 19.8 503 173 44.6 0.41 11 3.67 19.6 498 171 41.2 0.39 11 3.56 19.1 483 166 71 - Shaded area reflects ACCA (TVA) conditions. kW = total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors) 53.5 0.39 11 3.18 16.7 355 152 51.9 0.38 11 3.15 16.5 352 151 47.9 0.36 12 3.05 16.1 341 146 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 45.6 49.9 42.9 44.5 48.7 0.67 0.46 0.82 0.69 0.48 16 12 18 16 12 2.91 3.02 3.01 3.09 3.22 15.5 16.0 16.1 16.5 17.0 319 337 338 364 384 129 141 128 136 148 44.3 48.5 41.7 43.2 47.3 0.64 0.44 0.79 0.66 0.45 16 12 19 16 12 2.88 2.99 2.98 3.06 3.19 15.4 15.9 16.0 16.3 16.8 316 334 335 360 380 128 140 127 135 147 40.8 44.8 38.5 39.9 43.7 0.61 0.42 0.76 0.63 0.44 17 13 19 17 13 2.79 2.90 2.89 2.97 3.09 15.0 15.5 15.6 15.9 16.4 307 324 324 349 369 124 136 123 131 143 Product Specifications Expanded Cooling Data — GPC1448H41** SS-GPC14H SS-GPC14H www.goodmanmfg.com 48.6 0.98 25 2.47 13.5 240 114 47.2 0.94 26 2.44 13.4 237 113 43.5 0.90 26 2.37 13.1 230 110 MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR 1386 1582 1777 59 47.7 0.94 23 2.44 13.4 237 113 46.4 0.89 24 2.42 13.3 235 112 42.8 0.86 24 2.34 12.9 228 109 Airflow MBh S/T ∆T kW 1777 Amps HI PR LO PR MBh S/T ∆T kW 1582 Amps HI PR LO PR MBh S/T ∆T 1386 kW Amps HI PR LO PR 49.5 0.95 24 2.53 13.8 258 122 48.1 0.90 25 2.51 13.7 255 120 44.4 0.87 26 2.43 13.3 248 117 63 48.8 0.88 22 2.51 13.7 255 120 47.4 0.84 23 2.48 13.5 253 119 43.7 0.81 23 2.41 13.2 245 116 51.9 0.85 23 2.63 14.2 272 133 50.3 0.81 24 2.61 14.1 270 131 46.5 0.79 24 2.53 13.7 261 127 67 52.1 0.71 19 2.61 14.1 270 131 50.6 0.68 20 2.58 13.9 267 130 46.7 0.66 20 2.50 13.6 259 126 55.3 0.69 20 2.74 14.6 284 141 53.7 0.66 21 2.71 14.5 281 140 49.6 0.64 21 2.63 14.2 273 136 71 55.7 0.53 15 2.71 14.5 281 140 54.1 0.51 16 2.68 14.4 278 139 49.9 0.49 16 2.60 14.1 270 134 47.4 1.00 25 2.71 14.4 269 121 46.1 0.97 26 2.68 14.3 266 119 42.5 0.93 26 2.60 14.0 258 116 59 46.6 0.97 23 2.68 14.3 266 119 45.3 0.92 24 2.65 14.2 264 118 41.8 0.89 25 2.57 13.9 256 115 48.4 0.98 25 2.78 14.8 289 128 47.0 0.94 26 2.75 14.6 286 127 43.3 0.90 26 2.67 14.3 278 123 63 47.6 0.91 22 2.75 14.6 286 127 46.3 0.87 23 2.72 14.5 284 126 42.7 0.84 24 2.64 14.2 275 122 75 IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction access fittings. 85 80 IDB 65 50.7 0.89 23 2.89 15.2 305 140 49.2 0.84 24 2.86 15.1 302 139 45.4 0.81 25 2.77 14.7 293 135 67 50.9 0.74 19 2.86 15.1 302 139 49.4 0.71 20 2.83 15.0 299 137 45.6 0.68 21 2.75 14.6 290 133 54.0 0.72 20 3.01 15.7 319 149 52.5 0.68 21 2.98 15.6 315 148 48.4 0.66 21 2.89 15.2 306 143 71 54.4 0.55 16 2.98 15.6 315 148 52.8 0.53 16 2.95 15.5 312 146 48.8 0.51 16 2.86 15.1 303 142 46.3 1.00 24 2.92 15.6 306 125 45.0 0.99 26 2.89 15.4 303 124 41.5 0.96 26 2.80 15.1 294 120 59 45.5 1.00 24 2.89 15.4 303 124 44.2 0.95 24 2.86 15.3 300 123 40.8 0.91 25 2.78 14.9 291 119 47.2 1.00 24 3.00 15.9 329 133 45.8 0.96 26 2.97 15.8 326 132 42.3 0.92 26 2.88 15.4 316 128 49.4 0.91 23 3.12 16.4 347 146 48.0 0.87 24 3.09 16.3 344 144 44.3 0.83 25 2.99 15.8 334 140 45.2 1.00 23 3.11 16.5 348 132 43.9 1.00 26 3.08 16.4 345 130 40.5 0.99 27 2.98 16.0 334 127 46.1 1.00 24 3.19 16.9 375 140 44.7 0.99 26 3.16 16.8 371 139 41.3 0.95 26 3.06 16.3 360 135 48.2 0.94 23 3.32 17.4 396 153 46.8 0.89 24 3.28 17.3 392 152 43.2 0.86 25 3.18 16.8 380 147 51.5 0.76 20 3.45 18.0 413 163 50.0 0.72 21 3.42 17.9 409 161 46.1 0.70 21 3.31 17.4 396 157 71 51.8 0.59 16 3.42 17.9 409 161 50.3 0.56 16 3.38 17.7 405 160 46.4 0.54 17 3.28 17.3 392 155 42.9 1.00 22 3.27 17.5 392 138 41.7 1.00 24 3.23 17.4 388 137 38.5 1.00 26 3.14 16.9 376 133 59 42.2 1.00 22 3.23 17.4 388 137 41.0 1.00 24 3.20 17.2 384 135 37.8 0.98 25 3.10 16.8 373 131 43.8 1.00 23 3.35 17.9 422 147 42.5 1.00 25 3.32 17.7 417 145 39.2 0.99 26 3.22 17.3 405 141 63 43.1 1.00 22 3.32 17.7 417 145 41.9 0.95 23 3.29 17.6 413 144 38.6 0.92 24 3.19 17.2 401 140 45.8 0.97 23 3.49 18.5 445 160 44.5 0.93 24 3.45 18.3 441 159 41.1 0.89 24 3.35 17.8 428 154 67 46.1 0.81 19 3.45 18.3 441 159 44.7 0.78 20 3.42 18.1 436 157 41.3 0.75 20 3.31 17.7 423 152 105 48.9 0.79 20 3.63 19.1 464 171 47.5 0.75 21 3.59 18.9 460 169 43.8 0.73 21 3.48 18.4 446 164 71 49.2 0.61 15 3.59 18.9 460 169 47.8 0.58 16 3.56 18.8 455 167 44.1 0.56 16 3.45 18.3 441 162 39.8 1.00 21 3.40 18.5 433 143 38.6 1.00 22 3.37 18.3 429 141 35.6 1.00 24 3.27 17.8 416 137 59 39.1 1.00 20 3.37 18.3 429 141 37.9 1.00 22 3.34 18.1 424 140 35.0 0.99 23 3.24 17.7 412 136 40.5 1.00 21 3.49 18.9 466 152 39.4 1.00 23 3.46 18.7 461 150 36.3 1.00 24 3.36 18.2 447 146 63 39.9 1.00 21 3.46 18.7 461 150 38.8 0.96 22 3.43 18.6 457 149 35.8 0.93 22 3.32 18.1 443 144 42.5 0.98 22 3.63 19.5 492 166 41.2 0.94 22 3.60 19.3 487 164 38.0 0.90 23 3.49 18.8 472 159 67 42.7 0.82 18 3.60 19.3 487 164 41.4 0.78 19 3.56 19.1 482 163 38.2 0.75 19 3.45 18.6 468 158 115 45.3 0.80 19 3.78 20.2 513 177 44.0 0.76 19 3.74 20.0 508 175 40.6 0.73 20 3.63 19.5 493 170 71 45.6 0.61 14 3.74 20.0 508 175 44.3 0.58 15 3.70 19.8 503 173 40.9 0.56 15 3.59 19.3 488 168 Shaded area reflects AHRI (TVA) conditions. kW = total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors) 52.8 0.74 20 3.24 17.0 362 155 51.2 0.70 21 3.21 16.8 359 154 47.3 0.68 21 3.11 16.4 348 149 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 46.5 49.7 53.1 44.4 45.4 48.5 0.93 0.76 0.57 1.00 0.96 0.78 22 20 16 23 23 20 2.97 3.09 3.21 3.08 3.16 3.28 15.8 16.3 16.8 16.4 16.8 17.3 326 344 359 345 371 392 132 144 154 130 139 152 45.2 48.2 51.6 43.1 44.1 47.1 0.89 0.72 0.54 0.98 0.92 0.75 23 20 16 25 24 20 2.94 3.05 3.18 3.05 3.13 3.25 15.6 16.1 16.7 16.3 16.6 17.1 323 341 355 341 367 388 131 143 152 129 137 150 41.7 44.5 47.6 39.8 40.7 43.4 0.86 0.70 0.52 0.94 0.89 0.72 24 21 16 25 24 21 2.85 2.96 3.08 2.95 3.03 3.15 15.3 15.7 16.3 15.9 16.2 16.7 313 330 345 331 356 376 127 139 148 125 133 146 Product Specifications Expanded Cooling Data — GPC1448H41** (cont.) 15 16 www.goodmanmfg.com 57.3 0.81 24 3.73 15.8 241 109 55.6 0.77 25 3.70 15.7 238 108 51.3 0.75 25 3.61 15.3 231 105 MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR 1500 1700 1900 59 56.3 0.71 21 3.70 15.7 238 108 54.7 0.68 21 3.67 15.6 236 107 50.5 0.66 22 3.58 15.2 229 103 Airflow MBh S/T ∆T kW 1900 Amps HI PR LO PR MBh S/T ∆T kW 1700 Amps HI PR LO PR MBh S/T ∆T 1500 kW Amps HI PR LO PR 59.0 0.73 22 3.82 16.2 259 116 57.3 0.69 23 3.79 16.0 256 115 52.9 0.67 23 3.69 15.6 249 111 63 58.4 0.60 18 3.78 16.0 256 115 56.7 0.57 19 3.75 15.9 254 114 52.3 0.55 19 3.66 15.5 246 110 63.9 0.55 18 3.94 16.7 273 126 62.0 0.52 19 3.91 16.5 271 125 57.2 0.51 19 3.81 16.1 263 121 67 64.0 0.41 14 3.91 16.5 271 125 62.1 0.39 14 3.88 16.4 268 124 57.3 0.38 14 3.78 16.0 260 120 68.5 0.35 12 4.07 17.2 285 135 66.5 0.34 13 4.04 17.1 282 133 61.4 0.33 13 3.94 16.7 274 129 71 56.0 0.84 24 4.03 17.0 270 115 54.3 0.80 25 4.00 16.9 267 114 50.2 0.77 25 3.90 16.4 259 110 59 55.0 0.74 21 4.00 16.9 267 114 53.4 0.71 22 3.97 16.7 265 113 49.3 0.68 22 3.87 16.3 257 109 57.6 0.75 22 4.12 17.4 291 122 55.9 0.72 23 4.09 17.3 288 121 51.6 0.69 23 3.99 16.8 279 118 63 57.0 0.62 18 4.09 17.2 288 121 55.4 0.59 19 4.06 17.1 285 120 51.1 0.57 19 3.95 16.7 276 116 75 IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction access fittings. 75 70 IDB 65 62.4 0.57 18 4.26 17.9 307 134 60.6 0.54 19 4.23 17.8 304 132 55.9 0.52 19 4.12 17.3 295 128 67 62.5 0.43 14 4.23 17.8 304 132 60.7 0.41 14 4.19 17.6 301 131 56.0 0.39 14 4.08 17.2 292 127 66.9 0.37 13 4.41 18.6 320 142 65.0 0.35 13 4.37 18.4 317 141 60.0 0.34 13 4.26 17.9 307 137 71 54.6 0.86 24 4.30 18.4 307 120 53.0 0.82 25 4.26 18.2 304 118 49.0 0.79 26 4.15 17.8 295 115 59 53.7 0.76 21 4.26 18.2 304 118 52.2 0.72 22 4.23 18.1 301 117 48.1 0.70 22 4.12 17.6 292 114 56.3 0.77 22 4.40 18.8 330 127 54.6 0.74 23 4.36 18.6 327 126 50.4 0.71 24 4.25 18.2 317 122 60.9 0.58 18 4.55 19.4 349 139 59.1 0.56 19 4.51 19.2 346 137 54.6 0.54 19 4.39 18.7 335 133 53.3 0.89 24 4.53 19.6 350 126 51.8 0.85 25 4.49 19.4 346 124 47.8 0.82 26 4.38 18.9 336 121 54.9 0.80 22 4.64 20.0 376 134 53.3 0.76 23 4.60 19.9 373 132 49.2 0.73 24 4.48 19.3 361 128 59.4 0.60 18 4.79 20.7 397 146 57.7 0.58 19 4.75 20.5 394 144 53.2 0.55 19 4.63 19.9 382 140 63.8 0.39 13 4.96 21.4 415 155 61.9 0.37 13 4.92 21.2 410 154 57.1 0.36 13 4.79 20.7 398 149 71 50.6 0.92 24 4.73 20.8 393 132 49.2 0.88 25 4.69 20.6 390 130 45.4 0.85 25 4.57 20.0 378 126 59 49.8 0.81 21 4.69 20.6 390 130 48.3 0.78 22 4.65 20.4 386 129 44.6 0.75 22 4.53 19.9 374 125 52.1 0.83 22 4.84 21.3 423 140 50.6 0.79 23 4.80 21.1 419 139 46.7 0.76 23 4.67 20.5 407 134 63 51.6 0.68 18 4.80 21.1 419 139 50.1 0.65 19 4.76 20.9 415 137 46.2 0.62 19 4.63 20.3 403 133 56.4 0.63 18 5.01 21.9 447 153 54.8 0.60 19 4.96 21.7 443 151 50.6 0.58 19 4.83 21.2 429 147 67 56.5 0.47 14 4.96 21.7 443 151 54.9 0.45 14 4.92 21.5 438 150 50.7 0.43 14 4.79 21.0 425 145 105 60.6 0.40 12 5.18 22.7 466 163 58.8 0.38 13 5.14 22.5 462 161 54.3 0.37 13 5.00 21.9 448 156 71 46.9 0.93 22 4.90 21.9 435 136 45.5 0.89 23 4.86 21.7 430 135 42.0 0.86 24 4.73 21.2 418 131 59 46.1 0.82 19 4.86 21.7 430 135 44.8 0.78 20 4.82 21.6 426 133 41.3 0.75 20 4.69 21.0 413 129 48.3 0.83 21 5.02 22.5 468 145 46.9 0.80 21 4.97 22.3 463 143 43.3 0.77 22 4.84 21.7 449 139 63 47.8 0.69 17 4.97 22.3 463 143 46.4 0.65 17 4.93 22.1 459 142 42.8 0.63 18 4.80 21.5 445 138 52.3 0.63 17 5.19 23.2 494 158 50.8 0.60 18 5.14 23.0 489 157 46.8 0.58 18 5.01 22.4 474 152 67 52.4 0.47 13 5.14 23.0 489 156 50.9 0.45 13 5.10 22.8 484 155 46.9 0.44 13 4.97 22.2 470 150 115 56.1 0.41 12 5.37 24.0 515 168 54.5 0.39 12 5.32 23.8 510 167 50.3 0.37 12 5.18 23.2 495 162 71 - Shaded area reflects ACCA (TVA) conditions. kW = total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors) 65.3 0.38 13 4.70 20.1 364 148 63.4 0.36 13 4.66 19.9 360 146 58.6 0.35 13 4.54 19.4 350 142 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 55.7 61.0 52.4 54.3 59.5 0.63 0.44 0.78 0.65 0.45 18 14 21 18 14 4.36 4.51 4.49 4.60 4.75 18.6 19.2 19.4 19.9 20.5 327 345 346 373 393 126 137 124 132 144 54.1 59.2 50.9 52.7 57.8 0.60 0.42 0.75 0.62 0.43 19 14 22 19 14 4.32 4.47 4.46 4.56 4.71 18.5 19.1 19.2 19.7 20.3 324 342 343 369 390 125 136 123 131 143 49.9 54.7 47.0 48.7 53.3 0.58 0.40 0.72 0.60 0.42 19 15 22 19 15 4.21 4.35 4.34 4.44 4.59 18.0 18.6 18.7 19.2 19.8 314 332 333 358 378 121 132 119 127 139 Product Specifications Expanded Cooling Data — GPC1460H41** SS-GPC14H SS-GPC14H www.goodmanmfg.com 59.3 0.93 28 3.80 16.1 245 111 57.6 0.89 29 3.77 16.0 243 110 53.2 0.86 30 3.67 15.6 236 107 MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR 1500 1700 1900 59 58.3 0.89 27 3.77 16.0 243 110 56.6 0.85 28 3.73 15.8 241 109 52.3 0.82 28 3.64 15.4 233 106 Airflow MBh S/T ∆T kW 1900 Amps HI PR LO PR MBh S/T ∆T kW 1700 Amps HI PR LO PR MBh S/T ∆T 1500 kW Amps HI PR LO PR 60.5 0.90 28 3.88 16.5 264 118 58.7 0.86 29 3.85 16.3 262 117 54.2 0.83 30 3.75 15.9 254 113 63 59.6 0.84 25 3.85 16.3 262 117 57.9 0.80 26 3.82 16.2 259 116 53.4 0.77 27 3.72 15.8 251 112 63.3 0.81 26 4.01 17.0 279 129 61.5 0.78 27 3.98 16.8 276 128 56.8 0.75 28 3.88 16.4 268 124 67 63.7 0.68 22 3.98 16.8 276 128 61.8 0.65 23 3.94 16.7 273 126 57.1 0.63 23 3.84 16.2 265 123 67.6 0.66 23 4.14 17.5 291 137 65.6 0.63 24 4.11 17.4 288 136 60.6 0.61 24 4.01 17.0 279 132 71 68.1 0.51 18 4.11 17.4 288 136 66.1 0.48 18 4.08 17.2 285 135 61.0 0.47 19 3.97 16.8 277 131 58.0 0.97 29 4.10 17.3 275 117 56.3 0.92 30 4.07 17.2 273 116 51.9 0.89 30 3.97 16.7 265 113 59 57.0 0.92 27 4.07 17.2 273 116 55.3 0.88 28 4.03 17.0 270 115 51.0 0.85 28 3.93 16.6 262 112 59.1 0.93 28 4.20 17.7 296 125 57.4 0.89 29 4.16 17.5 294 124 52.9 0.86 30 4.05 17.1 285 120 63 58.2 0.87 26 4.16 17.5 294 124 56.5 0.83 27 4.13 17.4 291 122 52.2 0.80 27 4.02 17.0 282 119 75 IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction access fittings. 85 80 IDB 65 61.9 0.84 27 4.34 18.2 313 136 60.1 0.80 28 4.30 18.1 310 135 55.4 0.78 28 4.19 17.6 301 131 67 62.2 0.70 22 4.30 18.1 310 135 60.4 0.67 23 4.26 17.9 307 134 55.7 0.65 24 4.15 17.5 298 130 66.0 0.68 23 4.48 18.9 326 145 64.1 0.65 24 4.45 18.7 323 144 59.2 0.63 24 4.33 18.2 314 139 71 66.5 0.53 18 4.45 18.7 323 144 64.5 0.50 19 4.41 18.6 320 142 59.6 0.48 19 4.29 18.1 310 138 56.6 0.99 29 4.37 18.7 313 122 54.9 0.95 30 4.34 18.5 310 121 50.7 0.91 30 4.23 18.1 301 117 59 55.6 0.95 27 4.34 18.5 310 121 54.0 0.90 28 4.30 18.4 307 120 49.8 0.87 28 4.19 17.9 298 116 57.7 0.96 28 4.47 19.1 337 130 56.0 0.91 29 4.43 19.0 334 128 51.7 0.88 30 4.32 18.5 324 125 60.4 0.86 27 4.62 19.7 356 142 58.6 0.82 28 4.58 19.6 352 140 54.1 0.79 28 4.47 19.1 342 136 55.2 1.00 28 4.61 19.9 357 128 53.6 0.98 30 4.57 19.8 353 127 49.5 0.94 31 4.45 19.2 343 123 56.3 0.99 28 4.72 20.4 384 136 54.6 0.94 30 4.68 20.2 380 135 50.4 0.91 30 4.56 19.7 369 131 58.9 0.89 27 4.88 21.0 405 149 57.2 0.85 28 4.84 20.8 401 147 52.8 0.82 28 4.71 20.3 389 143 62.9 0.72 23 5.05 21.8 423 158 61.0 0.69 24 5.00 21.6 419 157 56.3 0.67 25 4.87 21.0 406 152 71 63.3 0.56 18 5.00 21.6 419 157 61.5 0.53 19 4.96 21.4 415 155 56.7 0.51 19 4.83 20.8 402 151 52.4 1.00 27 4.81 21.1 401 134 50.9 1.00 29 4.77 21.0 397 133 47.0 0.98 30 4.65 20.4 386 129 59 51.5 1.00 26 4.77 21.0 397 133 50.0 0.97 28 4.73 20.8 394 132 46.2 0.93 28 4.61 20.2 382 128 53.5 1.00 27 4.93 21.6 432 143 51.9 0.98 29 4.88 21.4 428 141 47.9 0.94 30 4.76 20.9 415 137 63 52.7 0.95 26 4.88 21.4 428 141 51.1 0.91 27 4.84 21.3 423 140 47.2 0.87 27 4.71 20.7 411 136 56.0 0.93 26 5.09 22.3 456 156 54.4 0.88 28 5.05 22.1 452 154 50.2 0.85 28 4.92 21.5 438 150 67 56.3 0.77 22 5.05 22.1 452 154 54.6 0.74 23 5.01 21.9 447 153 50.4 0.71 24 4.88 21.3 434 148 105 59.7 0.75 23 5.27 23.1 476 166 58.0 0.72 24 5.23 22.9 471 164 53.5 0.69 24 5.09 22.3 457 159 71 60.1 0.58 18 5.23 22.9 471 164 58.4 0.55 19 5.18 22.7 466 163 53.9 0.53 19 5.05 22.1 452 158 48.6 1.00 25 4.99 22.3 444 139 47.2 1.00 27 4.95 22.1 439 137 43.5 0.99 28 4.82 21.5 426 133 59 47.7 1.00 24 4.95 22.1 439 137 46.3 0.98 26 4.90 21.9 435 136 42.8 0.94 26 4.78 21.4 422 132 49.5 1.00 25 5.10 22.9 477 148 48.1 0.99 27 5.06 22.7 473 146 44.4 0.95 28 4.93 22.1 458 142 63 48.8 0.96 24 5.06 22.7 473 146 47.4 0.91 25 5.02 22.5 468 145 43.7 0.88 25 4.89 21.9 454 140 51.9 0.93 25 5.28 23.6 504 161 50.3 0.89 26 5.24 23.4 499 160 46.5 0.86 26 5.10 22.8 484 155 67 52.1 0.78 21 5.24 23.4 499 160 50.6 0.74 22 5.19 23.2 494 158 46.7 0.72 22 5.05 22.6 479 153 115 55.3 0.76 21 5.47 24.5 526 172 53.7 0.72 22 5.42 24.2 520 170 49.6 0.70 23 5.28 23.6 505 165 71 55.7 0.58 17 5.42 24.2 520 170 54.1 0.56 17 5.37 24.0 515 168 49.9 0.54 18 5.23 23.4 500 163 Shaded area reflects AHRI (TVA) conditions. kW = total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors) 64.4 0.70 23 4.78 20.4 371 151 62.6 0.67 24 4.74 20.3 368 149 57.7 0.64 24 4.62 19.7 357 145 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 56.8 60.7 64.9 54.3 55.4 59.2 0.89 0.72 0.54 1.00 0.92 0.75 26 22 18 28 26 23 4.43 4.58 4.74 4.57 4.68 4.84 19.0 19.6 20.3 19.8 20.2 20.8 334 352 368 353 380 401 128 140 149 127 135 147 55.2 58.9 63.0 52.7 53.8 57.5 0.85 0.69 0.52 0.93 0.87 0.71 27 23 19 28 27 24 4.40 4.55 4.70 4.53 4.64 4.80 18.8 19.4 20.1 19.6 20.0 20.7 331 349 364 350 376 398 127 139 148 126 134 146 50.9 54.4 58.2 48.6 49.7 53.1 0.82 0.66 0.50 0.90 0.84 0.69 27 24 19 29 27 24 4.28 4.43 4.58 4.42 4.52 4.67 18.3 18.9 19.6 19.1 19.5 20.1 321 339 353 339 365 386 123 135 143 122 130 141 Product Specifications Expanded Cooling Data — GPC1460H41** (cont.) 17 Product Specifications Airflow Data Model GPC14 24H41C* GPC14 24H41D/E* GPC14 30H41C* GPC14 30H41D/E* GPC14 36H41C* GPC14 36H41D* GPC14 42H41C* Speed* Volts Type T1 E.S.P. (In. of H₂O) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 230 CFM Watts 922 74 873 85 823 96 774 107 724 118 675 129 626 140 576 151 T2, T3 230 CFM Watts 922 74 873 85 823 96 774 107 724 118 675 129 626 140 576 151 T4, T5 230 CFM Watts 1069 102 1020 113 971 124 921 135 872 146 822 157 773 168 724 179 T1 230 CFM Watts 922 74 873 85 823 96 774 107 724 118 675 129 626 140 576 151 T2, T3 230 CFM Watts 922 74 873 85 823 96 774 107 724 118 675 129 626 140 576 151 T4, T5 230 CFM Watts 1231 168 1179 180 1127 193 1074 205 1022 218 969 230 917 243 865 255 T1 230 CFM Watts 1048 97 993 109 939 122 884 134 829 147 775 159 720 172 666 184 T2, T3 230 CFM Watts 1123 123 1068 136 1014 148 959 161 905 173 850 186 796 198 741 211 T4, T5 230 CFM Watts 1244 158 1189 170 1135 183 1080 195 1026 208 971 220 917 233 862 245 T1 230 CFM Watts 1048 97 993 109 939 122 884 134 829 147 775 159 720 172 666 184 T2, T3 230 CFM Watts 1123 123 1068 136 1014 148 959 161 905 173 850 186 796 198 741 211 T4, T5 230 CFM Watts 1462 241 1409 253 1357 266 1305 278 1252 291 1200 303 1147 315 1095 328 T1 230 CFM Watts 1151 132 1097 144 1042 156 988 169 933 181 879 194 824 206 770 219 T2, T3 230 CFM Watts 1261 131 1215 144 1169 157 1123 169 1076 182 1030 194 984 207 937 220 T4, T5 230 CFM Watts 1376 170 1330 182 1284 195 1237 207 1191 220 1145 233 1099 245 1052 258 T1 230 CFM Watts 1151 132 1097 144 1042 156 988 169 933 181 879 194 824 206 770 219 T2, T3 230 CFM Watts 1261 131 1215 144 1169 157 1123 169 1076 182 1030 194 984 207 937 220 T4, T5 230 CFM Watts 1577 277 1525 290 1472 302 1420 314 1367 327 1315 339 1263 352 1210 364 T1 230 CFM Watts 1165 118 1122 130 1080 142 1037 154 995 166 953 178 910 190 868 202 T2, T3 230 CFM Watts 1258 150 1216 162 1173 175 1131 187 1088 199 1046 211 1004 223 961 235 T4, T5 230 CFM Watts 1511 239 1469 251 1427 263 1384 275 1342 287 1299 299 1257 311 1214 323 * Speed set at T2 at the factory. 18 www.goodmanmfg.com SS-GPC14H Product Specifications Airflow Data (cont.) Model GPC14 42H41D* GPC14 42H41E* GPC14 48H41C* GPC14 48H41D* GPC14 48H41E* GPC14 60H41C* GPC14 60H41D* CFM Watts 0.1 1165 118 0.2 1122 130 0.3 1080 142 E.S.P. (In. of H₂O) 0.4 0.5 1037 995 154 166 0.6 953 178 0.7 910 190 0.8 868 202 230 CFM Watts 1258 150 1216 162 1173 175 1131 187 1088 199 1046 211 1004 223 961 235 T4, T5 230 CFM Watts 1645 285 1602 297 1560 309 1517 321 1475 333 1433 346 1390 358 1348 370 T1 230 CFM Watts 1181 146 1146 158 1112 174 1062 182 1022 196 977 208 937 218 891 227 T2, T3 230 CFM Watts 1410 222 1366 236 1328 250 1286 260 1248 273 1195 285 1155 296 1115 305 T4, T5 230 CFM Watts 1637 331 1605 348 1561 361 1527 374 1484 385 1436 392 1390 407 1345 417 T1 230 CFM Watts 1421 170 1367 182 1314 195 1260 208 1206 220 1152 233 1099 246 1045 258 T2, T3 230 CFM Watts 1696 287 1643 299 1589 312 1535 325 1481 337 1428 350 1374 363 1320 375 T4, T5 230 CFM Watts 1859 356 1805 368 1751 381 1698 394 1644 406 1590 419 1536 432 1483 444 T1 230 CFM Watts 1421 170 1367 182 1314 195 1260 208 1206 220 1152 233 1099 246 1045 258 T2, T3 230 CFM Watts 1696 287 1643 299 1589 312 1535 325 1481 337 1428 350 1374 363 1320 375 T4, T5 230 CFM Watts 1983 553 1928 565 1873 578 1818 591 1763 603 1708 616 1652 629 1597 641 T1 230 CFM Watts 1337 179 1297 190 1218 203 1155 210 1118 225 1088 243 1022 249 989 268 T2, T3 230 CFM Watts 1711 330 1640 341 1605 358 1537 370 1496 377 1441 394 1397 408 1347 418 T4, T5 230 CFM Watts 2002 498 1935 521 1885 516 1827 534 1767 551 1732 567 1669 571 1618 574 T1 230 CFM Watts 1507 168 1459 175 1410 183 1362 191 1314 199 1266 207 1218 214 1169 222 T2, T3 230 CFM Watts 1694 296 1646 303 1598 311 1549 319 1501 327 1453 334 1405 342 1357 350 T4, T5 230 CFM Watts 1965 481 1917 489 1869 496 1821 504 1773 512 1724 520 1676 528 1628 535 T1 230 CFM Watts 1507 168 1459 175 1410 183 1362 191 1314 199 1266 207 1218 214 1169 222 T2, T3 230 CFM Watts 1694 296 1646 303 1598 311 1549 319 1501 327 1453 334 1405 342 1357 350 T4, T5 230 CFM Watts 1919 449 1870 457 1822 465 1774 472 1726 480 1678 488 1629 496 1581 503 Speed* Volts Type T1 230 T2, T3 * Speed set at T2 at the factory. SS-GPC14H www.goodmanmfg.com 19 Product Specifications Heat Kit Electrical Data (Blower Only, Heat Mode) Model and Heat Kit Usage GPC1424H41** HKR-05*, HKR-05C* HKR-08*, HKR-08C* HKR-10*, HKR-10C* GPC1424H41D* HKR-05*, HKR-05C* HKR-08*, HKR-08C* HKR-10*, HKR-10C* GPC1424H41E* HKP-05C* HKR-08C* HKP-10C* GPC1430H41** HKR-05*, HKR-05C* HKR-08*, HKR-08C* HKR-10*, HKR-10C* HKP-15C* GPC1430H41D* HKR-05*, HKR-05C* HKR-08*, HKR-08C* HKR-10*, HKR-10C* HKP-15C* GPC1430H41E* HKP-05C* HKR-08C* HKP-10C* HKP-15C* GPC1436H41** HKR-05*, HKR-05C* HKR-08*, HKR-08C* HKR-10*, HKR-10C* HKP-15C* GPC1436H41D* HKR-05*, HKR-05C* HKR-08*, HKR-08C* HKR-10*, HKR-10C* HKP-15C* GPC1442H41** HKR-05*, HKR-05C* HKR-08*, HKR-08C* HKR-10*, HKR-10C* HKP-15C* HKP-20C Circuit #1 Circuit #2 Single-Point Kit MCA¹ MOP² MCA¹ MOP² MCA¹ MOP² Actual kW / BTU@ 240V 1.9 21 / 25 32 / 36 43 / 49 1.9 21 / 25 32 / 36 43 / 49 1.9 21 / 25 32 / 36 43 / 49 2.3 21 / 25 32 / 36 43 / 49 43 / 49 2.3 21 / 25 32 / 36 43 / 49 43 / 49 2.3 21 / 25 32 / 36 43 / 49 43 / 49 2.3 21 / 25 32 / 36 43 / 49 43 / 49 2.3 21 / 25 32 / 36 43 / 49 43 / 49 3.6 21 / 25 32 / 36 43 / 49 43 / 49 43 / 49 --25 / 25 35 / 40 45 / 50 --25 / 25 35 / 40 45 / 50 --25 / 25 35 / 40 45 / 50 --25 / 25 35 / 40 45 / 50 45 / 50 --25 / 25 35 / 40 45 / 50 45 / 50 --25 / 25 35 / 40 45 / 50 45 / 50 --25 / 25 35 / 40 45 / 50 45 / 50 --25 / 25 35 / 40 45 / 50 45 / 50 --25 / 25 35 / 40 45 / 50 45 / 50 45 / 50 --------------------------------21 / 25 --------21 / 25 --------21 / 25 --------21 / 25 --------21 / 25 --------21 / 25 43 / 49 --------------------------------25 / 25 --------25 / 25 --------25 / 25 --------25 / 25 --------25 / 25 --------25 / 25 45 / 50 -24 / 27 33 / 38 45 / 51 -29 41 54 -29 41 54 -24 / 27 34 / 39 45 / 52 67 / 77 -29 41 54 79 -29 41 54 79 -24 / 27 34 / 39 45 / 52 67 / 77 -29 41 54 79 -27 34 / 39 46 / 52 68 / 78 90 / 103 -30 / 30 40 / 40 60 / 60 -30 45 60 -30 45 60 -30 / 30 40 / 40 60 / 60 70 / 80 -30 45 60 80 -30 45 60 80 -40 / 40 40 / 40 60 / 60 70 / 80 -40 45 60 80 -40 / 40 40 / 40 60 / 60 70 / 80 90 / 110 --4.75 / 16,200 7 / 23,800 9.5 / 32,400 --4.75 / 16,200 7 / 23,800 9.5 / 32,400 --4.75 / 16,200 7 / 23,800 9.5 / 32,400 --4.75 / 16,200 7 / 23,800 9.5 / 32,400 14.25 / 48,600 --4.75 / 16,200 7 / 23,800 9.5 / 32,400 14.25 / 48,600 --4.75 / 16,200 7 / 23,800 9.5 / 32,400 14.25 / 48,600 --4.75 / 16,200 7 / 23,800 9.5 / 32,400 14.25 / 48,600 --4.75 / 16,200 7 / 23,800 9.5 / 32,400 14.25 / 48,600 --4.75 / 16,200 7 / 23,800 9.5 / 32,400 14.25 / 48,600 19.0 / 64,800 ¹ Minimum Circuit Ampacity @ 208 / 240 V ² Maximum Overcurrent Protection Device @ 208 / 240 V * Revision level that may or may not be designated C Circuit breaker option ^ Heat Kit requires three-phase power supply Note: HKP-15C* and HKP-20C* replace HKR-15C and HKR-20C respectively to meet new UL1995 requirements. 20 www.goodmanmfg.com SS-GPC14H Product Specifications Heat Kit Electrical Data (Blower Only, Heat Mode) Model and Heat Kit Usage GPC1442H41D* HKR-05*, HKR-05C* HKR-08*, HKR-08C* HKR-10*, HKR-10C* HKP-15C* HKP-20C GPC1442H41E* HKP-05C* HKR-08C* HKP-10C* HKP-15C* HKP-20C GPC1448H41** HKR-05*, HKR-05C* HKR-08*, HKR-08C* HKR-10*, HKR-10C* HKP-15C* HKP-20C GPC1448H41D* HKR-05*, HKR-05C* HKR-08*, HKR-08C* HKR-10*, HKR-10C* HKP-15C* HKP-20C GPC1448H41E* HKP-05C* HKR-08C* HKP-10C* HKP-15C* HKP-20C GPC1460H41** HKR-05*, HKR-05C* HKR-08*, HKR-08C* HKR-10*, HKR-10C* HKP-15C* HKP-20C GPC1460H41D* HKR-05*, HKR-05C* HKR-08*, HKR-08C* HKR-10*, HKR-10C* HKP-15C* HKP-20C GPC1460H41E* HKP-05C* HKR-08C* HKP-10C* HKP-15C* HKP-20C Circuit #1 Circuit #2 Single-Point Kit MCA¹ MOP² MCA¹ MOP² MCA¹ MOP² Actual kW / BTU@ 240V 3.6 21 / 25 32 / 36 43 / 49 43 / 49 43 / 49 3.6 21 / 25 32 / 36 43 / 49 43 / 49 43 / 49 3.6 21 / 25 32 / 36 43 / 49 43 / 49 43 / 49 3.6 21 / 25 32 / 36 43 / 49 43 / 49 43 / 49 3.6 21 / 25 32 / 36 43 / 49 43 / 49 43 / 49 7.5 21 / 25 32 / 36 43 / 49 43 / 49 43 / 49 7.5 21 / 25 32 / 36 43 / 49 43 / 49 43 / 49 7.5 21 / 25 32 / 36 43 / 49 43 / 49 43 / 49 --25 / 25 35 / 40 45 / 50 45 / 50 45 / 50 --25 / 25 35 / 40 45 / 50 45 / 50 45 / 50 --25 / 25 35 / 40 45 / 50 45 / 50 45 / 50 --25 / 25 35 / 40 45 / 50 45 / 50 45 / 50 --25 / 25 35 / 40 45 / 50 45 / 50 45 / 50 --25 / 25 35 / 40 45 / 50 45 / 50 45 / 50 --25 / 25 35 / 40 45 / 50 45 / 50 45 / 50 --25 / 25 35 / 40 45 / 50 45 / 50 45 / 50 --------21 / 25 43 / 49 --------21 / 25 43 / 49 --------21 / 25 43 / 49 --------21 / 25 43 / 49 --------21 / 25 43 / 49 --------21 / 25 43 / 49 --------21 / 25 43 / 49 --------21 / 25 43 / 49 --------25 / 25 45 / 50 --------25 / 25 45 / 50 --------25 / 25 45 / 50 --------25 / 25 45 / 50 --------25 / 25 45 / 50 --------25 / 25 45 / 50 --------25 / 25 45 / 50 --------25 / 25 45 / 50 -29 41 54 79 104 -29 41 54 79 104 -29 34 / 40 46 / 53 68 / 78 90 / 103 -32 43 56 81 106 -32 43 56 81 106 -37.3 37/40 48 / 54 70 / 80 92 / 105 -40 43 56 81 106 -40 43 56 81 106 -45 45 60 80 110 -45 45 60 80 110 -45 45 60 / 60 70 / 80 90 / 110 -50 50 60 90 110 -50 50 60 90 110 -60 60 60 / 60 80 / 90 100 / 110 -60 60 60 90 110 -60 60 60 90 110 --4.75 / 16,200 7 / 23,800 9.5 / 32,400 14.25 / 48,600 19.0 / 64,800 --4.75 / 16,200 7 / 23,800 9.5 / 32,400 14.25 / 48,600 19.0 / 64,800 --4.75 / 16,200 7 / 23,800 9.5 / 32,400 14.25 / 48,600 19.0 / 64,800 --4.75 / 16,200 7 / 23,800 9.5 / 32,400 14.25 / 48,600 19.0 / 64,800 --4.75 / 16,200 7 / 23,800 9.5 / 32,400 14.25 / 48,600 19.0 / 64,800 --4.75 / 16,200 7 / 23,800 9.5 / 32,400 14.25 / 48,600 19.0 / 64,800 --4.75 / 16,200 7 / 23,800 9.5 / 32,400 14.25 / 48,600 19.0 / 64,800 --4.75 / 16,200 7 / 23,800 9.5 / 32,400 14.25 / 48,600 19.0 / 64,800 See Notes on previous page. SS-GPC14H www.goodmanmfg.com 21 Product Specifications Dimensions A BACK VIEW (DUCT OPENINGS) W B D Model 22 Dimensions W" D" H" A" B" Chassis Size GPC1424H41** 66 33 30½ 22 30 Small GPC1430H41** 66 33 30½ 22 30 Small GPC1436H41** 66 33 30½ 22 30 Small GPC1442H41C*/D* 66 33 35½ 24 35 Medium GPC1442H41E* 66 33 30½ 22 30 Small GPC1448H41C*/D* 66 33 38½ 24 38¾ Large GPC1448H41E* 66 33 35½ 24 35 Medium GPC1460H41C*/D* 66 33 38½ 24 38¾ Large GPC1460H41E* 66 33 35½ 24 35 Medium www.goodmanmfg.com SS-GPC14H Product Specifications Wiring Diagram PU NOTE #3 BK RD BL RD BK BK RD BK T2 C T1 SEE NOTE 5 L1 YL GND GR BK 60 RD RD YL PU LVJB YL RD BR WH BL H YL BL C F RCCF GR YL C L G N 1 2 WH GR PLF 3 6 9 2 5 8 1 4 7 BR PU RD SA (IF USED) SEE NOTE 4 BR YL BK CM L2 SUPPLY VOLTAGE 208-240/1/60 T1 T2 R C COMP S H S.A. W2 C RD CONTROL BOX S C R COMPONENT LEGEND C CM COMP EM GND LVJB PLF RCCF C C RCCF F SA TR CM NOTE #4 CONTACTOR CONDENSER MOTOR COMPRESSOR EVAPORATOR MOTOR EQUIPMENT GROUND LOW VOLTAGE JUNCTION BOX FEMALE PLUG / CONNECTOR RUN CAPACITOR FOR COMPRESSOR AND FAN START ASSIST TRANSFORMER IF USED NOTE #2 EM 1 BR BL T H E R M O S T A T EM L1 N Y R G W1 COMP WH C YL RD GR WH BK PU BR BK WH GR 3 4 5 SEE NOTE 2 2 0 8 2 4 0 / 1 / L2 G L 3 2 NOTE #4 208-240 3 2 1 FACTORY WIRING LINE VOLTAGE LOW VOLTAGE OPTINAL HIGH VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRE CODE BK BLACK BL BLUE BR BROWN GR GREEN OR ORANGE PU PURPLE RD RED WH WHITE YL YELLOW TR 24V NOTES: 1 EM C 2 3 SEE NOTE #2 4 5 1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTO R ONLY. 2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE WHITE AND YELLOW LEADS FROM EM "2" AND "3" TO "4" AND "5". IF BOTH LEADS ARE ENERGIZED, THE HIGHER SPEED SETTING IS USED. 3. FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER. 4. START ASSIST FACTOR EQUIPED WHEN REQUIRED 5. USE COPPER CONDUCTORS ONLY. ++ USE N.E.C. CLASS 2 WIRE ⚡ BL 24V PU BL High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. PU 3 240 Warning 2 208 TR ⚠ 1 C Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. BK 6 PLF C R W2 W1 Y G SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION C THERMOSTAT 208-240/1/60 0140G00407 SS-GPC14H www.goodmanmfg.com 23 Product Specifications Accessories Accessory Description Small Chassis Item Number Medium/Large Chassis Downflow Economizer PCE101 PCE102/103 Downflow Plenum Kit PCP101 PCP102/103 Downflow Plenum Kit (R-8) PCP101 R8 PCP102 R8 /103 RB Elbow Flashing w/ R-8 Liner PCEF101 PCEF102/103 Emergency Heat Relay OT/EHR18-60 OT/EHR18-60 External Horizontal Filter Rack GPGHFR101 GPGHFR102/103 Horizontal Economizer DHZECNJPGCHM DHZECNJPGCHL Manual Damper PCMD101 PCMD102/103 Horizontal Manual Damper PCMDH101 PCMDH102/103 Motorized Damper PCMDM101 PCMDM102/103 Outdoor Thermostat w/ Lockout Stat OT18-60A OT18-60A Roof Curb PCCP101 PCCP102/103 Square to Round SQRPC101 SQRPC102/103 Square to Round for Horizontal Application SQRPCH101 SQRPCH102/103 Single-Point Wiring Kits Select the single-point kit accessory based on the unit model. Model Single-Point Kit Model Single-Point Kit GPC1424***41C* SPK-15 GPC1424***41D* SPK-20 GPC1430***41C* SPK-30 GPC1430***41D* SPK-30 GPC1436***41C* SPK-40 GPC1436***41D* SPK-40 GPC1442***41C* SPK-40 GPC1442***41D* SPK-45 GPC1448***41C* SPK-45 GPC1448***41D* SPK-50 GPC1460***41C* SPK-60 GPC1460***41D* SPK-60 Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. © 2014 Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA. 24 www.goodmanmfg.com SS-GPC14H