Preview only show first 10 pages with watermark. For full document please download

Gps Over Fibre Odu

   EMBED


Share

Transcript

Model Number: SRY-TX-L1-911  Compact waterproof housing  Redundant hot swap external power GPS Over Fibre ODU 1310nm Transmit supply  Antenna fail alarm pass through at the indoor receiver output  Provided with short circuit protected 12V 500mA antenna power  LED indicators for module & antenna power and status  For use with ETL’s GPS receive unit model SRY-RX-L1-266 Compact & Weatherproof Available with RF connector options:  50 Ω SMA  50 Ω N-type Housed in IP65 rated waterproof enclosure StingRay Flexible Mounting 850-2450 MHz Band on to pole or bolt to wall Monitoring Extended C-band Operating Frequency Optical and RF levels reported at receiver RF Parameters Capacity Antenna Power Connector Input ports Fibre output connector Frequency Connector & impedances Input Return Loss (dB) Gain flatness (dB) Input AGC level (dBm) Input AGC level (dBm) Output AGC level (dBm) Output AGC level (dBm) Noise Figure (dB) CNR (in any 4 MHz) (dB) 1dB GCP (dBm) 1dB Gain Compression point OIP3 (dBm) SFDR (dB/Hz2/3) Antenna Power Input RF Power (dBm) Module input voltage (V DC) DC consumption (W) External PSU input External PSU Redundancy Alarms Local Monitoring MTBF Broadcast V 1.0 E&OE Typ. Min Max Min Max Min One GNSS over Fibre links 50 dB gain, high rejection timing antenna recommended LEMO EGL.0K.303.CLA 50Ω SMA, N-type Senko IP-SC/APC 850MHz to 2450MHz 50Ω SMA 50Ω N-type 18 18 12 12 ±2.0 ±2.0 -10 -60 -40 -60 16 TBC 60 TBC e.g. Tallysman 33-3152-xx-yy-zzzz for GPS As fitted to unit. 12V power present, do not connect to power source. Use with tuned antenna to select required GNSS signal. Across band Levels total power including noise Min I/P for max O/P Set at receiver Set at receiver Typ. link 1.5GHz, -50dBm in & out Typ. link 1.5GHz, -50dBm in & out, gain fixed -30 TBC Typ. link 1.5GHz, -50dBm in & out, gain fixed -19 TBC 105 TBC 12Vdc, 500mA via RF in port 16 12 5 100-240VAC, 50/60Hz Dual redundant hot swap external units Antenna and link fail alarm set on indoor unit PSU voltage, RF amp current, temperature, laser power, RF modulation power, laser optical power monitored and reported via module LED > 120,000 hours Typ. link 1.5GHz, -50dBm in & out, gain fixed Typ. link 1.5GHz, -50dBm in & out Always on, short circuit protected Damage level Universal AC power unit available Max. consumption at steady state Separate Unit Use with PSU SRY-12-916-0KXX Marine Oil & Gas Contact ETL if remote monitoring and control is required. SNG & VSAT Satellite Teleport www.etlsystems.com Model Number: SRY-TX-L1-911 GNSS Over Fibre ODU Technical specifications and operating parameters Optical Parameters Laser Type Optical Wavelength (nm) Optical Power output (dBm) Optical Connectors Operating Temperature (°C) Storage Temperature (°C) Location Humidity Altitude DFB 1310 ± 10 3.8 ±2.5 Two stage optical isolator for improved performance Single mode fibre Operational Storage Weight Dimensions Front Panel Colour Environmental conditions -20°C to +55°C -40°C to +85°C Indoor or outdoor use to IP65 20-90% non-condensing 10,000 feet 30,000 feet Physical Dimensions & Parameters 1Kg See mechanical drawing RAL9003 – White (Semi-Matte) Mount out of direct sunlight Relative Humidity Above Mean Sea Level Tbc Tbc Mounting flanges provided Physical Dimensions (mm) The specification is subject to regular reviews and will be updated from time to time as part of our continuing product development and improved specification accuracy. Note-1: Typical parameters are guide figures and measured data may deviate from the quoted figures. ETL endeavours to exceed the quoted typical parameters where practically possible. Note-2: Operation beyond the quoted limits stated above may cause instantaneous and permanent damage. For reliable long term operation do not exceed the parameters given in above. Note-3: The spec table is subject to regular reviews and will be updated from time to time as part of our continuing product development and improved spec accuracy. ETL SYSTEMS LIMITED Coldwell Radio Station Madley Hereford England HR2 9NE TELEPHONE +44 (0)1981 259020 FACSIMILE +44 (0)1981 259021 EMAIL [email protected] WEB www.etlsystems.com V 1.0 E&OE