Preview only show first 10 pages with watermark. For full document please download

Gramma Switch Info Sheet

   EMBED


Share

Transcript

INFO SHEET Model No: GRAMMA_KIT1 Gramma Switch Kit includes Receiver & 2 Gramma Switches SPECIFICATIONS: Encryption............................. Code-Hopping Frequency..............................433.92MHz Receiving range....................150m Power input range.................10 ~ 26V AC/DC Current drain..........................13mA, 12VDC Memory capacity....................80 Gramma Devices Relay output times.................0.5 second momentary ...............................................1 second momentary ...............................................3 / 30 second momentary ...............................................Latching ...............................................1 & 3 Minute Dimensions............................65 X 48 x 20mm Weight Packed.......................0.050kg / 50grams Warranty.................................1 year Model no................................RX1-GRAMMA Release date..........................March 2015 Note: This Device is intended for use on Shabbat and Festivals and has been approved by The Tzomet Institute and is endorsed by the Beth Din of Johannesburg. Pressing the button on a Gramma Switch does not draw power from the battery. There is a computer (microprocessor) inside the Gramma Switch that is always on, unlike a normal remote. This microprocessor sends a pulse, approximately every 10 seconds, which checks to see if the button has been pressed. If the computer (microprocessor) detects that the button has been pressed, the microprocessor waits for the next pulse to confirm that the button was pressed. The microprocessor will then send a signal to change the state of the alarm. Elvey is a leading distributor of electronic security equipment in Africa. Our vision is to assist in the protection of people and property by providing quality, innovative products and solutions to the electronic security industry, thereby ensuring a safe and secure future for all. INFO SHEET Direction for use: To Activate 1. To activate the alarm in stay mode, press button once 2. Wait at least 20 seconds for alarm to activate 3. If the alarm fails to activate, repeat the above steps To Deactivate 1. To deactivate the alarm, press button once 2. Wait at least 20 seconds to confirm deactivation 3. If the alarm fails to deactivate, repeat the above Very important, do not press the button twice within 20 seconds, or you will confuse the computer (microprocessor). If you did so accidentally, check whether your alarm is activated or not, wait 10 seconds and arm or disarm. Explanation: • • • • • • • • • • The switch used on a Gramma Switch is a static switch not the usual switch found on a remote. Pressing the button on a Gramma Switch does not draw power from the battery. There is a computer (microprocessor) inside the Gramma Switch that is always on, unlike a normal remote. This computer (microprocessor) sends a pulse, approximately every 10 seconds, which checks to see if the button has been pressed. If the computer (microprocessor) detects that the button has been pressed, the computer (microprocessor) waits for the next pulse to confirm that the button was pressed. If the computer (microprocessor) confirms that the button was pressed, the microprocessor will then send a signal to change the state of the alarm. If the alarm is off, the alarm will go into stay mode. If the alarm is in stay mode, the alarm will be deactivated. The device has been approved for use on Shabbat and Festivals by the Tzomet Institute and is endorsed by the Beth Din of Johannesburg who supervised its manufacture. This device may only be used for security purposes. The expected battery life in the remote is estimated to last 12 months. This is based on the Gramma Switch only being used over Shabbat and Festivals. Should the Gramma Switch be used more frequently, battery life will last for a shorter period. INFO SHEET Wiring up to an Alarm System Wire the Receiver up to a Spare Zone on the Alarm panel and configure the zone to be a Stay Arm / Disarm. Use the relevant EOL resistors on the panel and connect to the Normally Closed (NC) terminal block of the Receiver. INFO SHEET Programming Please follow the steps below to Learn in the Gramma Device to the receiver. The unit can store up to 80 keyfobs. When memory has reached its limit the unit will automatically exit out of program mode and sound a long beep. The unit auto exits after 10 seconds. Erasing Individual remotes Defaulting This function will Default (Erase all) Gramma Switches from the units memory Relay time setting. INFO SHEET Elvey is a leading distributor of electronic security equipment in Africa. Our vision is to assist in the protection of people and property by providing quality, innovative products and solutions to the electronic security industry, thereby ensuring a safe and secure future for all. +27 (0) 11 401 6700 + 27 (0) 11 401 6753 [email protected] www.elvey.co.za