Preview only show first 10 pages with watermark. For full document please download

Grundfos Ups 200 Data Sheet

   EMBED


Share

Transcript

GRUNDFOS DATA BOOKLET Series 200 UPS and UPSD circulator pumps 50 Hz Contents General data Performance range Product range Single-head pumps Twin-head pumps Type key Energy labelling Applications Heating systems Domestic hot water systems Cooling and air-conditioning systems Data sheet 3 4 4 5 5 5 6 6 6 6 Functions Speed switch Standard module Pumps with protection module Protection module indicator lights Relay module Operating modes of twin-head pumps 7 7 7 8 8 9 Connection Electrical data Electrical connection Pumps with standard module Single-head pumps with protection module Single-head pump with relay module Twin-head pumps with relay module Signal output of twin-head pumps Installation Terminal box positions 10 10 10 11 11 12 13 13 13 UPS 32-30 F 220, UPSD 32-30 F 220 UPS 32-60 F 220, UPSD 32-60 F 220 UPS 32-120 F 220, UPSD 32-120 F 220 UPS 40-30 F 250, UPSD 40-30 F 250 UPS 40-30 F 254 UPS 40-60/4 F 250 UPS 40-60/2 F 220 UPS 40-60/2 F 250, UPSD 40-60/2 F 250 UPS 40-120 F 250, UPSD 40-120 F 250 UPS 40-180 F 250 UPS 40-185 F 250 UPS 50-30 F 280, UPSD 50-30 F 280 UPS 50-60/4 F 280, UPSD 50-60/4 F 280 UPS 50-60/2 F 280, UPSD 50-60/2 F 280 UPS 50-60/2 F 300 UPS 50-120 F 280, UPSD 50-120 F 280 UPS 50-180 F 280, UPSD 50-180 F 280 UPS 50-185 F 280 UPS 65-30 F 340, UPSD 65-30 F 340 UPS 65-60/4 F 340, UPSD 65-60/4 F 340 UPS 65-60/2 F 340, UPSD 65-60/2 F 340 UPS 65-60/2 F 280 UPS 65-120 F 280 UPS 65-120 F 340, UPSD 65-120 F 340 UPS 65-180 F 340, UPSD 65-180 F 340 UPS 65-185 F 340 UPS 80-30 F 360, UPSD 80-30 F 360 UPS 80-60 F 360, UPSD 80-60 F 360 UPS 80-120 F 360, UPSD 80-120 F 360 UPS 100-30 F 450, UPSD 100-30 F 450 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 Accessories Construction Construction Material specification Sectional drawing 14 14 14 Technical data Pumped liquids Temperature limits Technical data Curve conditions 2 15 15 15 15 Accessories Counter flanges Protection modules Relay module Insulation kits Base plate Blanking flanges 46 46 46 46 47 47 48 Further product documentation WebCAPS WinCAPS 49 50 General data Series 200 Performance range p [kPa] H [m] 17 160 16 XX-185 15 140 14 13 120 XX-180 12 11 100 10 9 80 XX-120 8 7 60 6 5 XX-60 40 4 3 XX-30 2 1 2 3 4 6 8 10 15 20 30 40 50 60 70 80 Q [m³/h] 1 2 3 4 5 6 7 8 9 10 20 Q [l/s] TM03 3344 0806 20 3 General data Series 200 Product range Single-head pumps Pressure stage Pump type 4 Voltage [V] PN 6 / PN 6 / PN 10 PN 6 PN 10 PN 6 bronze PN 10 bronze PN 10 bronze Poles 1 x 230-240 3 x 230 3 x 400-415 2 UPS 32-30 F 220 • • • • • UPS 32-60 F 220 • • • • • • UPS 32-120 F 220 • • • • • • UPS 40-30 F 250 • • • • • UPS 40-30 F 254 * • • UPS 40-60/2 F 220 * • • • UPS 40-60/2 F 250 • • • • • • UPS 40-60/4 F 250 • • • • • UPS 40-120 F 250 • • • • • UPS 40-180 F 250 • • • • UPS 40-185 F 250 • UPS 50-30 F 280 • • • • • UPS 50-60/2 F 280 • • • • • • • • • • • • • • • • • • • UPS 50-60/2 F 300 * • UPS 50-60/4 F 280 • • • • • UPS 50-120 F 280 • • • • • • UPS 50-180 F 280 • • • • • • UPS 50-185 F 280 • • • UPS 65-30 F 340 • UPS 65-60/2 F 280 * • UPS 65-60/2 F 340 • • • UPS 65-60/4 F 340 • • • UPS 65-120 F 280 * • UPS 65-120 F 340 • • UPS 65-180 F 340 • • UPS 65-185 F 340 • • • • • • • • • • • • • • • • • • • • • • • • • • • UPS 80-30 F 360 • • • • • • UPS 80-60 F 360 • • • • • • UPS 80-120 F 360 • • • • • • UPS 100-30 F 450 • • • • • • 4 • • • • General data Series 200 Twin-head pumps Pressure stage Pump type Voltage [V] PN 6 / PN 6 PN 10 PN 6 /PN 10 bronze PN 6 bronze PN 10 bronze PN 10 Poles 1 x 230-240 3 x 230 3 x 400-415 2 UPSD 32-30 F 220 • • • • UPSD 32-60 F 220 • • • • • UPSD 32-120 F 220 • • • • • UPSD 40-30 F 250 • • • • UPSD 40-60 F 250 • • • • • UPSD 40-120 F 250 • • • • • UPSD 50-30 F 280 • • • • UPSD 50-60/2 F 280 • • • • UPSD 50-60/4 F 280 • • • • UPSD 50-120 F 280 • • • • • UPSD 50-180 F 280 • • • • • UPSD 65-30 F 340 • • • • UPSD 65-60/2 F 340 • • • • UPSD 65-60/4 F 340 • • • • UPSD 65-120 F 340 • • • • • UPSD 65-180 F 340 • • • • UPSD 80-30 F 360 • • • • UPSD 80-60 F 360 • • • • UPSD 80-120 F 360 • • • • UPSD 100-30 F 360 • • • • 4 • • • • • • • • • • • • Type key Example UPS (D) 65 -60 (/2) F(-) 280 Type range Twin-head pump Nominal flange diameter [mm] Max. head [dm] Number of motor poles, (stated if available both as 2- and 4-pole motor) F - Pump with flanges B - Pump with bronze housing Port-to-port length [mm] Energy labelling Grundfos UPS circulator pumps are provided with the energy label, except the bronze pumps (B-version). The energy label indicates the energy-saving level of the pump. The energy classification system has seven levels, i.e. from A to G. Level A is the best. The energy label can be used to compare pumps of the same type and size. The energy labelling of the pumps are stated on the data sheet of the pump in question. 5 General data Series 200 Applications General examples of systems in which UPS, UPSD pumps are suitable are shown below. Grundfos circulator pumps, types UPS, UPSD, are designed for circulation of liquids in heating and airconditioning systems. Pumps with bronze pump housings are suitable for circulation in domestic hot water systems. UPS, UPSD are a complete line of circulator pumps with three speeds. The pumps come both as single and twin-head pumps. Heating systems • One- and two-pipe heating systems • Main pumps M • Zone pumps • Boiler shunt pumps M M • Pumps for heating surfaces M • Calorifers • Underfloor heating systems • Solar heating systems M • Heat recovery systems Out In TM01 0168 0697 • Geothermal heating systems Domestic hot water systems • Domestic hot water systems TM01 0169 0697 M Cooling and air-conditioning systems • Two-pipe air-conditioning systems • Main pumps M • Zone pumps M M • Pumps for refrigeration units • Geothermal heating systems • Heat recovery systems 6 TM01 0170 0697 • Heat pump systems Functions Series 200 Speed switch The pump offers three speeds for adjustment of pump performance to the system in question. H H 1 2 Q 3 Q Q TM00 9247 4595 H Fig. 1 Pump performance at the three speeds The speeds of the various speed switch positions are shown in the table below: Switch position Speed in % of maximum speed approx. 60 % approx. 70 % 2 approx. 80 % approx. 85 % 3 100 % 100 % Single-phase pumps Single-phase pumps incorporate a green indicator light only: Indicator Description light On The electricity supply has been switched on. Off The electricity supply has been switched off. Three-phase pumps Three-phase pumps incorporate a green and a red indicator light: Indicator lights Single-phase pumps Three-phase pumps 1 Indicator lights on standard module The function of the indicator lights on the terminal box is as shown in the following tables. Change to a lower speed enables reduction in energy consumption and less noise in the system. Green Red Description Off Off The electricity supply has been switched off. On Off The electricity supply has been switched on. On On The electricity supply has been switched on. The direction of rotation is wrong. Pumps with protection module TM00 9747 0602 Indicator lights and speed indication TM01 3879 4798 Fig. 2 Indicator lights on terminal box Standard module The module is standard in single-head pumps and is also available for twin-head pumps. Connect the pump to the mains via an external contactor. Connect the contactor to the pump’s built-in thermal overload switch to protect the pump against overload at all three speeds. Speed switch Protection module The protection module is supplied as an accessory for single-head and twin-head pumps. When equipped with a protection module, the pump can be connected to an external switch directly, as the builtin protection against overheating protects the pump at all three speeds. Furthermore, the module has two indicator lights. TM00 9237 0602 Standard module Fig. 4 Protection module Fig. 3 Standard module 7 Functions Series 200 Protection module indicator lights The function of the indicator lights is shown in the table below. Indicator lights Description Green Red Off Off The pump has been stopped. The electricity supply has been switched off, thermally cut out or a phase is failing. On Off The pump is operating. On On Three-phase pumps only: The pump is operating, but the direction of rotation is not correct. On The pump has been cut out by the thermal switch. Off Signal output of relay module The relay module is equipped with a signal output for external operating or fault indication. By means of the selector switch, the output can be used as: • Operation signal output between terminals 2 and 3 or • Fault signal output between terminals 1 and 3. Functions of indicator ligths and signal output Indicator lights Green Note: Pumps with protection module must not be connected to a frequency converter. Off Red Signal output Operation Fault Off 1 2 3 NC NO C 1 2 3 NC NO C 1 2 3 NC NO C 1 2 3 NC NO C Description The pump has been stopped. The electricity supply has been switched off or a phase is failing. Relay module The relay module is standard in twin-head pumps and an optional extra for single-head pumps. The module enables direct connection of the pump to an external mains switch and an external operating or fault indication device. The signal output for an external signal device can be set to activation during operation or fault by means of the selector switch. As standard, the signal outputs of relay modules in twin-head pumps are interconnected so that the pumps are operating alternately as duty pump and standby pump. The pump is connected directly to the mains as the pump incorporates overload protection at all three speeds. If the pump has been cut out by the thermal overload switch, it will restart automatically when it has cooled to normal temperature, provided the external on/ off contact is closed. Permanently on Off The pump is running. PermaPermanently on nently on 1 2 3 NC NO C Off Permanently on 1 2 3 NC NO C Flashes 1 2 3 NC NO C Off 1 2 3 NC NO C Flashes 1 2 3 NC NO C Permanently on 1 2 3 NC NO C 1 2 3 NC NO C 1 2 3 NC NO C Only three-phase pumps: The pump is running, but with wrong direction of rotation. The pump has been cut out by the thermal overload switch. The pump has been stopped by an external on/off switch. The pump is or has been cut out by the thermal overload switch and it has been stopped by an external on/off switch. Note: Pumps with relay module must not be connected to a frequency converter. Relay module Speed switch TM00 9236 4596 Selector switch for signal output Fig. 5 Relay module Indicator lights on relay module The indicator lights on pumps with relay module have more detailed operating and fault indications. All pumps with relay module are equipped with a green and a red indicator light. Their functions are as shown in the table below. 8 Functions Series 200 Operating modes of twin-head pumps Twin-head pumps have a relay module in both terminal boxes, which are interconnected by a 4-core cable. P1 TM00 9243 4101 P2 Fig. 6 Twin-head pump In addition to the signal functions, the signal output of the relay module for twin-head pumps can be used for controlling the operating mode of pump 1 and 2. It is possible to choose between three operating modes: 1. Alternating operation (factory setting). The pumps operate alternately as duty and standby pump, respectively. Changeover takes place every 24 hours. If the duty pump is cut out due to a fault, the standby pump will automatically start. During changeover both pumps will be running for a short period to ensure a low-noise changeover. 2. Standby operation. The pumps operate continuously as duty and standby pump, respectively. If the duty pump is cut out due to a fault, the standby pump will automatically start at a signal from the output of the duty pump. The sequence can be changed to make the standby pump operate as duty pump. 3. Single-pump operation. The pumps run independently without communicating with each other. 9 Connection Series 200 Electrical data Electrical connection Supply voltage and frequency: The electrical connection and protection should be carried out in accordance with local regulations. Earthing or neutralization can be used for protection against indirect contact. A current- or voltage-operated earth-leakage circuit breaker can be used as extra protection. Never make any connections in the pump terminal box unless the electricity supply has been switched off. The pump must be earthed and connected to an external mains switch. The operating voltage and frequency are marked on the pump nameplate. Make sure that the motor is suitable for the electricity supply on which it will be used. 1 x 230-240 V, 50 Hz 3 x 230 V, 50 Hz 3 x 400-415 V, 50 Hz. Motor protection: The pump requires no external motor protection if the motor is fitted with a protection module. Back-up fuse: Max. 10 A. Enclosure class: IP 44. Insulation class: H. Screwed cable entries: 1 x M20 for mains connection. 1 x M20 for signal output (blanked-off if pump with standard module). 1 x M16 for capacitor connection (only single-phase pumps). EMC (electromagnetic EN 61 000-6-2. compatibility): EN 61 000-6-3. Thermal overload switch Voltage 250 V AC Current cos phi = 1.0: 2.5 A cos phi = 0.6: 1.6 A Start/stop input (relay module) External potential-free contact. Maximum load: 250 V, 1.5 mA. Minimum load: 100 V, 0.5 mA. Pumps with standard module The pump must be connected to the mains via an external contactor. The contactor is to be connected to the pump’s built-in thermal overload switch at terminals T1 and T2 to protect the pump against overheating at all three speeds. Note: If the pump is also protected by means of a motor starter, the starter must be set to the current consumption of the pump at the chosen speed. The motor starter setting must be changed every time the pump speed is changed. The current consumption at the various speeds is stated on the pump nameplate. External impulse switches Operating/fault signal output (relay module) Internal potential-free changeover contact. Maximum load: 250 V, 2 A, AC. Minimum load: 5 V, 100 mA, DC. Single-phase T1 T2 N L K K Stop Start K N L Three-phase without neutral T1 T2 L3 L2 L1 K Stop Stop Start L3 L2 L1 K K Start K K K L3 L2 L1 Fig. 7 External impulse switches 10 N L3 L2 L1 TM00 9173 0305 T1 T2 Three-phase with neutral Connection Series 200 External changeover switch Single-head pump with relay module The pump can be connected directly to the mains as it incorporates protection against overheating at all three speeds. The relay module has a signal output for an external operating or fault signal device. By means of the selector switch the signal output can be used as operation or fault signal output: Single-phase T1 T2 N L K K Stop/Start Operation N L Three-phase without neutral Fault Three-phase with neutral Note: The selector switch must not have been set to alternating operation (used in connection with twin-head pumps). T1 T2 L3 L2 L1 L3 L2 L1 Operating indication K K K Stop/Start Stop/Start K N L3 L2 L1 L3 L2 L1 1 TM00 9172 0305 T1 T2 3 Fig. 8 External changeover switch N 1 3 L L3 L2 L1 1 2 3 NC NO C 7 8 N L N L N L L3 L2 L1 Fig. 9 Electrical connections, protection module 7 8 N L L3 L2 L1 L3 L2 L1 Fault indication 1 TM01 3402 0305 L 3 Fig. 10 Operating indication 3 NC NO C N 1 2 TM00 9174 0305 The pump can be connected directly to the mains as the pump features built-in protection against overheating at all three speeds. The figure below shows the electrical connection of single-phase and three-phase pumps. NC NO C NC NO C 1 2 3 7 8 N L 1 2 3 7 8 L3 L2 L1 N N L N L3 L2 L1 L L TM00 9175 0305 Single-head pumps with protection module Fig. 11 Fault indication 11 Connection Series 200 Twin-head pumps with relay module The pumps are interconnected by a 4-core cable and factory-set to operating alternately as duty and standby pump. Changeover takes place every 24 hours. The following figures shows the electrical connections and the selector switch setting for the various operating modes. 1 P2 P1 NC NO C 1 2 3 NC NO C 7 8 N L 1 2 3 7 8 N L Alternating operation (factory setting) N L 3 1 2 3 P2 P1 NC NO C 7 8 N L 1 2 3 NC NO C 7 8 N L N L 1 2 NC NO C 7 8 L3 L2 L1 8 1 2 L3 L2 L1 3 7 8 L3 L2 L1 1 2 3 7 8 L3 L2 L1 L3 L2 L1 Fig. 13 Standby operation P1 L3 L2 L1 L3 L2 L1 TM00 9176 0305 3 NC NO C 7 L3 L2 L1 3 1 2 3 N L P2 NC NO C P1 TM00 9177 0305 1 P2 NC NO C N L Standby operation with pump 2 as duty pump and pump 1 as standby pump. Note: In this operating mode the selector switch of pump 1 must not have been set to alternating operation. 1 P2 P1 Fig. 12 Alternating operation Standby operation Standby operation with pump 1 as duty pump and pump 2 as standby pump. Note: In this operating mode the selector switch of pump 2 must not have been set to alternating operation. NC NO C 1 2 3 NC NO C 7 8 N L 1 2 3 7 8 N L N L N L 3 P1 NC NO C 1 2 3 NC NO C 7 8 L3 L2 L1 L3 L2 L1 1 2 3 7 8 L3 L2 L1 L3 L2 L1 TM00 9178 0305 P2 Fig. 14 Standby operation In the case of single-pump operation the cable between the pumps is to be removed. The pumps must be set individually and connected separately to mains, see page 11 "Single-head pump with relay module". 12 Connection Series 200 Terminal box positions The signal output of twin-head pumps can be used directly, provided it is not already being used for communication between the pumps. If an output that is used for communication between the pumps is to be used as signal output, an intermediate relay is required. See example below. The example shows a single-phase pump in alternating operation with external fault indication in case of fault on pump 2 or both pumps. Single-head pumps TM02 1398 1101 Signal output of twin-head pumps Fig. 17 Permissible terminal box positions 1 P2 NC NO C 3 NC NO C 7 8 1 N L 2 3 7 8 N L N L TM00 9179 0305 N L L N L N TM02 1399 1101 1 2 Twin-head pumps P1 Fig. 15 Alternating operation with external fault indication Installation The pump must be installed with horizontal motor shaft. Fig. 18 Permissible terminal box positions and flow direction of twin-head pumps Flow direction TM02 1404 1101 For standard terminal box positions, see technical data from page 15. Fig. 16 Flow direction Note: Twin-head pumps in vertical pipes with downward liquid flow or in horizontal pipes must always run at maximum speed. Twin-head pump mounted in horizontal pipes must be fitted with an automatic air vent in the upper part of the pump housing. 13 Construction Construction The UPS, UPSD pumps are of the canned rotor type, i.e. pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricated by the pumped liquid. Attention has been focused on using as few materials as possible, and the use of materials that might cause problems in connection with disposal have been omitted. The pump offers these features: • Three-speed motor Series 200 Material specification Pos. Description Material 1 Terminal box 2 Inspection screw Brass with nickel 3 Nameplate Composite PA66 Stator housing Aluminium AlSi 10Cu2 4 Stator windings Copper wire Stator winding cap Composite PETP 5 Cheese-head screw Steel 8.8 6 O-rings EPDM rubber 7 • Ceramic radial bearings DIN W.-Nr. Composite PA66 Outer bearing ring Aluminium oxide/SiC Rotor can Stainless steel 1.4301 Stainless steel Stainless steel 1.4305 1.4404 1.4301 • Carbon thrust bearing 8 Shaft (cast iron pumps) Shaft (bronze pumps) • Stainless-steel rotor can, bearing plate and rotor cladding Rotor cladding Stainless steel 9 Thrust bearing Carbon MY 106 • Aluminium-alloy stator housing 10 Bearing plate Stainless steel Inner bearing ring Aluminium oxide/SiC 1.4301 • Cast iron or bronze pump housing 11 Stop ring Stainless steel 1.4435 • Stator with built-in thermal overload switch. 12 Split cone Stainless steel 1.4305 13 Impeller Stainless steel 1.4301 14 Nut Stainless steel 1.4305 15 Neck ring Stainless steel / PTFE 1.4301 Cast iron EN-GJL-250 EN-JL-1040 16 Pump housing Bronze CuSn10, DIN 1705 17 Anti-friction ring Brass/Stainless steel Non-return flap (Twin-head pumps) EPDM rubber Splash protection Stainless steel 18 2.1050.01 1.4305 TM02 1397 2102 Sectional drawing Fig. 19 Sectional drawing 14 Technical data Series 200 Pumped liquids Thin, clean, non-aggressive and non-explosive liquids, not containing any solid particles, fibres or mineral oil. In domestic hot water systems, it is advisable to use bronze pumps only for water with a degree of hardness lower than approx. 14 °dH. For water with a higher degree of hardness, use a close-coupled pump type TP. If the pump is installed in a heating system, the water should meet the requirements of accepted standards on water quality in heating systems, e.g. the German standard VDI 2035. The pumps must not be used for the transfer of inflammable liquids such as diesel oil and petrol. Temperature limits Ambient temperature: 0 °C to 40 °C Liquid temperature - for short periods: +140 °C - continuously: –10 °C to +120 °C - domestic hot water: Up to +60 °C Storage temperature: –30 °C to +55 °C. Depending on the cast-iron version and the pump application, the maximum liquid temperature may be limited by local regulations and laws. Technical data Relative humidity: Max. 95 %. Sound-pressure level: The sound-pressure level of the pump is lower than 41 dB(A) (reference: 20 mPa). Test pressure: PN 6: 10 bar ~ 1.0 MPa PN 10: 15 bar ~ 1.5 MPa PN 6/10: 15 bar ~ 1.5 MPa. Test liquid: +20 °C water containing corrosion inhibitor. Inlet pressure To avoid cavitation noise, the following minimum pressures are required at the pump suction flange: Liquid temperature Pump type 75°C 90°C 120°C UPS, UPSD [bar] [bar] [bar] 32-30 F 220 0.05 0.05 1.3 32-60 F 220 0.05 0.2 1.5 32-120 F 220 0.4 0.7 1.95 40-30 F 250 0.05 0.15 1.45 1.45 40-30 F 254* 0.05 0.15 40-60/4 F 250 0.05 0.05 1.3 40-60/2 F 220* 0.05 0.2 1.5 40-60/2 F 250 0.15 0.45 1.75 40-120 F 250 0.1 0.4 1.7 40-180 F 250 0.4 0.7 1.95 40-185 F 250 0.55 0.90 1.8 50-30 F 280 0.05 0.1 1.4 50-60/4 F 280 0.05 0.15 1.45 50-60/2 F 280 0.05 0.35 1.65 50-60/2 F 300* 0.15 0.45 1.75 1.95 50-120 F 280 0.4 0.7 50-180 F 280 0.35 0.65 1.9 50-185 F 280 0.85 1.0 2.15 1.95 65-30 F 340 0.4 0.7 65-60/4 340 0.55 0.85 2.1 65-60/2 F 280* 0.05 0.35 1.65 65-60/2 340 0.45 0.75 2.0 65-120 F 280* 0.4 0.7 1.95 65-120 F 340 0.9 1.2 2.45 65-180 F 340 0.7 1.0 2.25 65-185 F 340 0.9 1.3 2.35 80-30 F 360 1,15 1.45 2.7 80-60 F 360 1.2 1.5 2.75 80-120 F 360 1.6 1.9 3.15 100-30 F 450 1.05 1.35 2.6 * Only available as single-head pump (UPS) Curve conditions The guidelines below apply to the performance curves in the following data sheets: 1. Due to the danger of overheating the pumps must not be used at a flow below 0.1 x Q at best efficiency point. 2. The bold parts of the curves show the recommended performance range. 3. Test liquid: Airless water. 4. The curves apply to a liquid temperature of 20 °C. 5. All curves show average values and should not be used as guarantee curves. If a stated minimum performance is required, individual measurements must be made. 6. The conversion between head H [m] and pressure p [kPa] has been made for water with a density of ρ = 1000 kg/m3. For liquids with other densities, e.g. hot water, the discharge pressure is proportional with the density. 7. Power curves, efficiency curves and electrical data for twin-head pumps apply to single-pump operation. 15 Data sheet UPS 32-30 F 220, UPSD 32-30 F 220 Series 200, 50 Hz UPS 32-30 F 220, UPSD 32-30 F 220 Inlet pressure H p [kPa] [m] 24 2.4 20 2.0 16 1.6 12 1.2 3 tm [°C] 2 Hmin [bar] 1 0.8 4 0.4 0 3 x 400-415 V 0.0 0 0.0 2 4 0.5 6 1.0 1.5 8 120 1.3 2.0 2.5 Eta [%] 3 TMA0 9419 0497 40 10 Eta 0 0 2 4 6 8 10 Q [m³/h] 60 35 0.26 0.58 Speed 2 70 40 0.31 0.56 Speed 3 115 85 0.87 0.33 Speed 1 60 35 0.15 0.58 Speed 2 70 40 0.18 0.56 Speed 3 115 85 0.50 0.33 Energy class 3 x 400-415 V UPS 32-30 F 220 D E UPSD 32-30 F 220 D E D4 B7 D2 D1 L3 D5 M Rp 1/4 B4 B8 H4 B3 H1 TM02 0701 3601 L1 B 2 H1 Speed 1 3 x 230 V H3 H2 B1 Cos ϕ Pump type 20 2 1 I1/1 [A] Energy labelling 30 80 Pmin [W] Single-head pumps are available with bronze housing, type B. 3.0Q [l/s] 120 Pmax [W] Series 200 is also available for 1 x 230-240 V. 10 Q [m³/h] P1 [W] 0 90 0.05 Electrical data 3 x 230 V 8 75 0.05 H3 H2 D3 B5 B9 D3 B7 B6 D4 B6 D2 TM02 0703 3601 D5 L3 L2 L1 B2 D1 Rp 1/4 B4 B5 D3 M D3 Dimensions and weights Pump type L1 UPS 32-30 F 220 6/10 220 L2 L3 B1 B2 B3 B4 B5 B6 B7 B8 B9 H1 H2 H3 H4 D1 D2 - 110 135 141 UPSD 32-30 F 220 6/10 220 103 52 - - 75 75 - D3 D4 D5 M Ship. vol. Net Gross [m3] 80 110 110 68 245 312 104 32 76 90/100 140 14/19 M12 16.0 17.4 141 360 180 180 100 200 * Weights of bronze versions are approx. 10 % higher. 16 Weights [kg]* Dimensions [mm] PN - - 68 245 313 - 32 76 90/100 140 14/19 M12 30.6 32.4 0.026 0.044 Data sheet UPS 32-60 F 220, UPSD 32-60 F 220 Series 200, 50 Hz UPS 32-60 F 220, UPSD 32-60 F 220 Inlet pressure H p [kPa] [m] 50 tm [°C] 3 Hmin [bar] 5 2 40 4 30 3 20 2 10 90 120 0.2 1.5 Electrical data 1 3 x 230 V 1 3 x 400-415 V 0 75 0.05 0 0 0.0 2 4 0.5 1.0 6 8 1.5 10 2.0 2.5 Eta [%] 40 3 160 I1/1 [A] Cos ϕ Speed 1 120 70 0.37 0.82 Speed 2 140 75 0.40 0.88 Speed 3 185 105 0.68 0.68 Speed 1 120 70 0.21 0.82 Speed 2 140 75 0.23 0.88 Speed 3 185 105 0.39 0.68 Single-head pumps are available with bronze housing, type B. 3.5Q [l/s] P1 [W] Pmin [W] Series 200 is also available for 1 x 230-240 V. 12 Q [m³/h] 3.0 Pmax [W] Energy labelling 2 120 30 1 40 TMA0 9421 0497 20 Eta 10 0 0 0 2 4 6 8 10 12 Q [m³/h] 3 x 230 V 3 x 400-415 V UPS 32-60 F 220 C C UPSD 32-60 F 220 C C H3 H2 B1 H1 D4 B7 D2 D1 L3 D5 M Rp 1/4 B4 B8 H4 B3 H3 H2 H1 TM02 0701 3601 L1 B 2 Energy class Pump type 80 D3 B5 B9 D3 B7 B6 D4 B6 D2 TM02 0703 3601 D5 L3 L2 L1 B2 D1 Rp 1/4 B4 B5 D3 M D3 Dimensions and weights Pump type Weights [kg]* Dimensions [mm] PN L1 L2 L3 B1 B2 B3 B4 B5 B6 B7 B8 B9 H1 H2 H3 H4 D1 D2 UPS 32-60 F 220 6/10 220 - 110 135 141 UPSD 32-60 F 220 6/10 220 103 52 - - 75 75 - D3 D4 D5 M Ship. vol. Net Gross [m3] 80 110 110 68 242 310 103 32 76 90/100 140 14/19 M12 16.1 17.5 141 360 180 180 100 200 - - 68 242 310 - 32 76 90/100 140 14/19 M12 31.6 33.3 0.026 0.044 * Weights of bronze versions are approx. 10 % higher. 17 Data sheet UPS 32-120 F 220, UPSD 32-120 F 220 Series 200, 50 Hz UPS 32-120 F 220, UPSD 32-120 F 220 Inlet pressure H p [kPa] [m] 80 8 70 7 60 6 50 5 40 4 3 2 tm [°C] 75 90 120 Hmin [bar] 0.4 0.7 1.95 Electrical data 1 3 x 230 V Pmax [W] Pmin [W] I1/1 [A] Cos ϕ Speed 1 245 120 0.73 0.84 Speed 2 280 130 0.82 0.86 30 3 Speed 3 400 170 1.36 0.74 20 2 Speed 1 245 120 0.42 0.84 10 1 Speed 2 280 130 0.47 0.86 Speed 3 400 170 0.78 0.74 0 3 x 400-415 V 0 0 2 4 0.0 0.5 1.0 6 1.5 8 2.0 10 2.5 12 3.0 Series 200 is also available for 1 x 230-240 V. Q [m³/h] 3.5 Single-head pumps are available with bronze housing, type B. 4.0Q [l/s] P1 [W] Eta [%] 3 Energy labelling 320 40 2 160 20 Eta 80 10 0 0 0 2 4 6 8 10 12 Q [m³/h] 3 x 400-415 V C C UPSD 32-120 F 220 D D D4 B7 D2 D1 L3 D5 M Rp 1/4 B4 B8 H4 B3 H3 H2 H1 TM02 0701 3601 L1 B 2 H1 3 x 230 V UPS 32-120 F 220 H3 H2 B1 Energy class Pump type 30 1 TMA0 9423 0497 240 D3 B5 B9 D3 B7 B6 D4 B6 D2 TM02 0703 3601 D5 L3 L2 L1 B2 D1 Rp 1/4 B4 B5 D3 M D3 Dimensions and weights Pump type L1 UPS 32-120 F 6/10 220 L2 - L3 B1 B2 B3 B4 B5 B6 B7 B8 B9 H1 H2 H3 H4 D1 D2 110 135 141 UPSD 32-120 F 6/10 220 103 52 - - 75 75 - D3 D4 D5 M Ship. vol. Net Gross [m3] 80 110 110 68 242 310 103 32 76 90/100 140 14/19 M12 16.3 141 360 180 180 100 200 * Weights of bronze versions are approx. 10 % higher. 18 Weights [kg]* Dimensions [mm] PN - - 68 243 311 - 32 76 90/100 140 14/19 M12 33.0 17.6 0.026 34.5 0.045 Data sheet UPS 40-30 F 250, UPSD 40-30 F 250 Series 200, 50 Hz UPS 40-30 F 250, UPSD 40-30 F 250 Inlet pressure p [kPa] 24 H [m] tm [°C] 3 Hmin [bar] 2.4 2 20 1.6 12 1.2 0.8 4 0.4 0 120 1.45 1 3 x 230 V 8 90 0.15 Electrical data 2.0 16 75 0.05 3 x 400-415 V 0.0 0 0.0 2 4 0.5 1.0 6 1.5 8 2.0 10 2.5 12 3.0 3.5 4.0 Eta [%] 3 I1/1 [A] Cos ϕ Speed 1 80 45 0.30 0.68 Speed 2 90 50 0.35 0.65 Speed 3 140 100 0.90 0.39 Speed 1 80 45 0.17 0.68 Speed 2 90 50 0.20 0.65 Speed 3 140 100 0.52 0.39 Single-head pumps are available with bronze housing, type B. 4.5 Q [l/s] P1 [W] Pmin [W] Series 200 is also available for 1 x 230-240 V Q [m³/h] 14 Pmax [W] 120 Energy labelling 30 2 80 20 TMA0 9425 0497 Eta 40 10 0 0 0 2 4 6 8 10 12 14 Q [m³/h] H1 3 x 400-415 V UPS 40-30 F 250 C C UPSD 40-30 F 250 D D D4 B7 D2 D1 L3 D5 M Rp 1/4 B4 B8 H4 B3 H3 H2 H1 TM02 0701 3601 L1 B 2 3 x 230 V H3 H2 B1 Energy class Pump type 1 D3 B5 B9 D3 B7 B6 D4 B6 D2 TM02 0703 3601 D5 L3 L2 L1 B2 D1 Rp 1/4 B4 B5 D3 M D3 Dimensions and weights Pump type Weights [kg]* Dimensions [mm] PN L1 L2 L3 B1 B2 B3 B4 B5 B6 B7 B8 B9 H1 H2 H3 H4 D1 D2 UPS 40-30 F 250 6/10 250 - 125 135 141 UPSD 40-30 F 250 6/10 250 126 45 - - 85 75 - D3 D4 D5 M Ship. vol. Net Gross [m3] 120 118 110 68 249 317 108 40 84 100/110 150 14/19 M12 18.8 20.1 141 360 180 180 100 200 - - 68 249 317 - 40 84 100/110 150 14/19 M12 32.0 34.4 0.027 0.044 * Weights of bronze versions are approx. 10 % higher. 19 Data sheet UPS 40-30 F 254 Series 200, 50 Hz UPS 40-30 F 254 Inlet pressure p [kPa] 24 H [m] tm [°C] 3 Hmin [bar] 2.4 2 20 1.6 12 1.2 0.8 4 0.4 0 0.0 120 1.45 1 3 x 400-415 V 8 90 0.15 Electrical data 2.0 16 75 0.05 Pmax [W] Pmin [W] I1/1 [A] Cos ϕ Speed 1 80 45 0.17 0.68 Speed 2 90 50 0.20 0.65 Speed 3 140 100 0.52 0.39 Energy labelling Energy class Pump type 0 2 4 0.5 1.0 6 8 10 12 3 x 400-415 V Q [m³/h] 14 UPS 40-30 F 254 0.0 1.5 2.0 2.5 3.0 3.5 4.0 P1 [W] D 4.5 Q [l/s] 3 Eta [%] 120 30 2 80 20 Eta 40 TMA0 9425 0497 1 10 0 0 0 2 4 6 8 10 12 14 Q [m³/h] H3 B1 B7 B 2 D4 H2 H1 D2 L3 TM03 2075 3605 L1 D1 D5 M D3 B4 Rp 1/4 B5 D3 Dimensions and weights Pump type Weights [kg]* Dimensions [mm] PN L1 L2 L3 B1 B2 B3 B4 B5 B6 B7 B8 B9 H1 H2 H3 H4 D1 D2 UPS 40-30 F 254 20 6/10 254 - 127 135 141 - 85 75 - 120 118 110 68 249 317 - D3 D4 D5 M Ship. vol. Net Gross [m3] 40 84 100/110 150 14/19 M12 18.8 20.1 0.027 Data sheet UPS 40-60/4 F 250 Series 200, 50 Hz UPS 40-60/4 F 250 Inlet pressure tm [°C] p [kPa] 50 Hmin [bar] H [m] 3 75 90 120 0.05 0.05 1.3 Electrical data 5 2 40 4 30 3 Pmax [W] 1 20 3 x 230 V 2 3 x 400-415 V 10 1 0 0 Pmin [W] I1/1 [A] Cos ϕ Speed 1 175 90 0.56 0.79 Speed 2 215 100 0.66 0.82 Speed 3 320 145 1.15 0.70 Speed 1 175 90 0.32 0.79 Speed 2 215 100 0.38 0.82 Speed 3 320 145 0.66 0.70 Series 200 is also available for 1 x 230-240 V 0 0.0 4 0.8 8 1.6 2.4 12 3.2 16 4.0 20 4.8 5.6 P1 [W] Q [l/s] 3 320 Single-head pumps are available with bronze housing, type B. Q [m³/h] Energy labelling Eta [%] 40 Energy class Pump type 240 30 2 20 Eta 80 10 0 0 8 12 16 20 B1 H1 Q [m³/h] H3 H2 D4 B7 D2 D1 L3 D5 M Rp 1/4 H4 TM02 0701 3601 L1 B 2 C TMA0 9427 0497 1 4 3 x 400-415 V C UPS 40-60/4 F 250 160 0 3 x 230 V B4 B8 D3 B5 B9 D3 Dimensions and weights Pump type Weights [kg]* Dimensions [mm] PN L1 L2 L3 B1 B2 B3 B4 B5 B6 B7 B8 B9 H1 H2 H3 H4 D1 D2 D3 D4 D5 M Ship. vol. Net Gross [m3] UPS 40-60/4 F 250 6/10 250 - 125 135 141 - 100 100 - 120 134 134 75 231 306 115 40 84 100/110 150 14/19 M12 20.8 22.4 0.034 * Weights of bronze versions are approx. 10 % higher. 21 Data sheet UPS 40-60/2 F 220 Series 200, 50 Hz UPS 40-60/2 F 220 Inlet pressure H p [kPa] [m] 50 tm [°C] 3 Hmin [bar] 5 75 90 120 0.15 0.45 1.75 2 40 Electrical data 4 30 3 20 2 10 1 0 0 1 3 x 400-415 V Pmax [W] Pmin [W] I1/1 [A] Cos ϕ Speed 1 120 70 0.21 0.82 Speed 2 140 75 0.23 0.88 Speed 3 185 105 0.39 0.68 Energy labelling 0 2 4 6 8 10 12 Q [m³/h] Energy class Pump type 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3 x 400-415 V 3.5Q [l/s] P1 [W] 3 160 UPS 40-60/2 F 220 Eta [%] 40 C 2 120 30 1 20 Eta 40 TMA0 9421 0497 80 10 0 0 0 2 4 6 8 10 12 Q [m³/h] H3 B1 B7 B 2 D4 H2 H1 D2 L3 TM03 2075 3605 L1 D1 D5 M D3 B4 Rp 1/4 B5 D3 Dimensions and weights Pump type Weights [kg]* Dimensions [mm] PN L1 L2 L3 B1 B2 B3 B4 B5 B6 B7 B8 B9 H1 H2 H3 H4 D1 D2 UPS 40-60/2 F 220 22 6/10 220 - 110 135 141 - 75 75 - 80 - - 68 242 310 - D3 D4 D5 M Ship. vol. Net Gross [m3] 40 84 100/110 150 14/19 M12 18.3 19.6 0.027 Data sheet UPS 40-60/2 F 250, UPSD 40-60/2 F 250 Series 200, 50 Hz UPS 40-60/2 F 250, UPSD 40-60/2 F 250 Inlet pressure p [kPa] 50 H [m] 5 40 4 30 3 20 2 10 tm [°C] 3 Hmin [bar] 90 120 0.45 1.75 2 Electrical data 1 Pmax [W] 3 x 230 V 1 3 x 400-415 V 0 75 0.15 0 0 0.0 4 8 0.8 1.6 12 2.4 3.2 16 4.0 20 4.8 5.6 3 30 TMA0 9429 0497 15 Eta 0 0 0 4 8 12 16 20 Q [m³/h] 0.43 0.89 125 0.50 0.87 Speed 3 250 170 0.80 0.78 Speed 1 155 115 0.25 0.89 Speed 2 175 125 0.29 0.87 Speed 3 250 170 0.46 0.78 Energy class 3 x 230 V 3 x 400-415 V C C UPSD 40-60/2 F 250 D D D4 B7 D2 D1 L3 D5 M Rp 1/4 B4 B8 H4 B3 H3 H2 H1 TM02 0701 3601 L1 B 2 H1 115 175 UPS 40-60/2 F 250 H3 H2 B1 155 Speed 2 Pump type 1 80 Speed 1 Energy labelling 45 2 160 Cos ϕ Single-head pumps are available with bronze housing, type B. Q [l/s] Eta [%] 240 I1/1 [A] Series 200 is also available for 1 x 230-240 V Q [m³/h] P1 [W] Pmin [W] D3 B5 B9 D3 B7 B6 D4 B6 D2 TM02 0703 3601 D5 L3 L2 L1 B2 D1 Rp 1/4 B4 B5 D3 M D3 Dimensions and weights Pump type Weights [kg]* Dimensions [mm] PN L1 L2 L3 B1 B2 B3 B4 B5 B6 B7 B8 B9 H1 H2 H3 H4 D1 D2 UPS 40-60/2 F 250 6/10 250 - 125 135 141 UPSD 40-60/2 F 250 6/10 250 125 45 - - 75 75 - D3 D4 D5 M Ship. vol. Net Gross [m3] 80 110 110 68 248 316 103 40 84 100/110 150 14/19 M12 16.6 17.9 141 360 180 180 100 200 - - 68 246 314 - 40 84 100/110 150 14/19 M12 32.6 35.6 0.026 0.044 * Weights of bronze versions are approx. 10 % higher. 23 Data sheet UPS 40-120 F 250, UPSD 40-120 F 250 Series 200, 50 Hz UPS 40-120 F 250, UPSD 40-120 F 250 Inlet pressure p [kPa] 80 H [m] 3 tm [°C] 75 90 120 2 Hmin [bar] 0.1 0.4 1.7 8 Electrical data 1 60 6 40 4 20 3 x 230 V 2 3 x 400-415 V 0 0 0 0.0 4 8 0.8 1.6 12 2.4 3.2 16 4.0 4.8 5.6 Eta [%] 40 3 400 I1/1 [A] Cos ϕ Speed 1 290 175 0.85 0.85 Speed 2 330 190 0.97 0.85 Speed 3 460 260 1.60 0.72 Speed 1 290 175 0.49 0.85 Speed 2 330 190 0.56 0.85 Speed 3 460 260 0.92 0.72 Single-head pumps are available with bronze housing, type B. Q [l/s] P1 [W] Pmin [W] Series 200 is also available for 1 x 230-240 V Q [m³/h] 20 Pmax [W] Energy labelling 2 300 30 1 Eta 100 TMA0 9431 0497 20 10 0 0 0 4 8 12 Energy class Pump type 200 16 20 Q [m³/h] 3 x 400-415 V UPS 40-120 F 250 C C UPSD 40-120 F 250 D D H3 H2 B1 H1 D4 B7 D2 D1 L3 D5 M Rp 1/4 B4 B8 H4 B3 H3 H2 H1 TM02 0701 3601 L1 B 2 3 x 230 V D3 B5 B9 D3 B7 B6 D4 B6 D2 TM02 0703 3601 D5 L3 L2 L1 B2 D1 Rp 1/4 B4 B5 D3 M D3 Dimensions and weights Pump type Weights [kg]* Dimensions [mm] PN L1 L2 L3 B1 B2 B3 B4 B5 B6 B7 B8 B9 H1 H2 H3 H4 D1 D2 UPS 40-120 F 250 6/10 250 - 125 135 141 UPSD 40-120 F 250 6/10 250 125 45 - - 75 - D3 D4 D5 M 80 110 110 68 246 314 103 40 84 100/110 150 14/19 M12 17.7 19.2 141 360 180 180 100 200 * Weights of bronze versions are approx. 10 % higher. 24 75 Ship. vol. Net Gross [m3] - - 68 245 313 - 40 84 100/110 150 14/19 M12 33.0 37.7 0.026 0.044 Data sheet UPS 40-180 F 250 Series 200, 50 Hz UPS 40-180 F 250 Inlet pressure p [kPa] 120 H [m] 100 10 12 3 tm [°C] 75 90 120 2 Hmin [bar] 0.4 0.7 1.95 Electrical data 1 80 8 60 6 3 x 230 V 20 0 4 2 3 x 400-415 V 0 0 0.0 4 0.8 8 1.6 2.4 12 3.2 16 4.0 20 4.8 5.6 6.4 P1 [W] Eta [%] 2 600 30 Eta 200 15 0 0 0 4 8 12 16 20 24 Q [m³/h] B1 Speed 1 490 235 1.43 0.86 Speed 2 570 250 1.63 0.86 Speed 3 770 350 2.26 0.85 Speed 1 490 235 0.82 0.86 Speed 2 570 250 0.94 0.86 Speed 3 770 350 1.30 0.85 Energy class Pump type 3 x 230 V 3 x 400-415 V C C UPS 40-180 F 250 H3 H2 D4 B7 D2 D1 L3 D5 M Rp 1/4 B4 B8 H4 TM02 0701 3601 L1 B 2 H1 Cos ϕ Energy labelling 45 1 400 I1/1 [A] Single-head pumps are available with bronze housing, type B. Q [l/s] 3 Pmin [W] Series 200 is also available for 1 x 230-240 V 24 Q [m³/h] TMA0 9433 0497 40 Pmax [W] D3 B5 B9 D3 Dimensions and weights Pump type Weights [kg]* Dimensions [mm] PN L1 L2 L3 B1 B2 B3 B4 B5 B6 B7 B8 B9 H1 H2 H3 H4 D1 D2 UPS 40-180 F 250 6/10 250 - 125 145 169 - 100 100 - D3 D4 D5 M Ship. vol. Net Gross [m3] 80 134 134 68 240 308 106 40 84 100/110 150 14/19 M12 21.4 22.8 0.034 * Weights of bronze versions are approx. 10 % higher. 25 Data sheet UPS 40-185 F 250 Series 200, 50 Hz UPS 40-185 F 250 Inlet pressure p [kPa] 160 H [m] tm [°C] 3 Hmin [bar] 90 120 0.90 1.8 16 Electrical data 2 120 70 0.55 12 Pmax [W] Pmin [W] I1/1 [A] Cos ϕ Speed 1 620 415 1.04 0.86 Speed 2 705 450 1.18 0.86 Speed 3 975 580 1.80 0.78 1 80 8 40 4 0 0 3 x 400-415 V Series 200 is also available for 1 x 230-240 V Energy labelling 0 4 8 12 16 20 Q [m³/h] Energy class Pump type 0.0 0.8 1.6 2.4 3.2 4.0 4.8 5.6 Q [l/s] 3 x 230 V 3 x 400-415 V C C UPS 40-185 F 250 P1 [W] Eta [%] 800 40 3 30 2 1 400 20 200 TMA1 4941 1199 600 10 Eta 0 0 0 4 8 12 16 20 Q [m³/h] B1 H3 H2 D4 B7 D2 D1 L3 D5 M Rp 1/4 B4 B8 H4 TM02 0701 3601 L1 B 2 H1 D3 B5 B9 D3 Dimensions and weights Pump type L1 L2 L3 B1 B2 B3 B4 B5 B6 B7 B8 B9 H1 H2 H3 H4 D1 D2 UPS 40-185 F 250 6/10 250 - 125 142 155 26 Weights [kg] Dimensions [mm] PN - 100 102 - 96 - - 67 243 310 - D3 D4 D5 M Ship. vol. Net Gross [m3] 42 88 100/110 150 14/19 M12 19.7 21.4 0.034 Data sheet UPS 50-30 F 280, UPSD 50-30 F 280 Series 200, 50 Hz UPS 50-30 F 280, UPSD 50-30 F 280 Inlet pressure p [kPa] 24 20 H [m] 1.6 12 1.2 Hmin [bar] 2 75 90 120 1.85 1.0 2.15 Electrical data 2.0 16 tm [°C] 3 2.4 1 Pmax [W] 3 x 230 V 8 0.8 4 0.4 0 0.0 3 x 400-415 V 0 0.0 4 8 0.8 1.6 12 2.4 3.2 16 4.0 4.8 5.6 160 3 Eta [%] 40 120 Speed 1 90 55 0.37 0.62 Speed 2 100 60 0.38 0.66 Speed 3 160 105 0.90 0.44 Speed 1 90 55 0.21 0.62 Speed 2 100 60 0.22 0.66 Speed 3 160 105 0.52 0.44 Energy labelling 30 2 1 Eta 40 10 0 0 0 4 8 12 16 20 Q [m³/h] B1 H1 3 x 230 V 3 x 400-415 V UPS 50-30 F 280 C C UPSD 50-30 F 280 D D H3 H2 D4 B7 D2 D1 L3 D5 M Rp 1/4 B4 B8 H4 B3 H3 H2 H1 TM02 0701 3601 L1 B 2 Energy class Pump type 20 TMA0 9435 0497 80 Cos ϕ Single-head pumps are available with bronze housing, type B. Q [l/s] P1 [W] I1/1 [A] Series 200 is also available for 1 x 230-240 V. Q [m³/h] 20 Pmin [W] D3 B5 B9 D3 B7 B6 D4 B6 D2 TM02 0703 3601 D5 L3 L2 L1 B2 D1 Rp 1/4 B4 B5 D3 M D3 Dimensions and weights Pump type Weights [kg]* Dimensions [mm] PN L1 L2 L3 B1 B2 B3 B4 B5 B6 B7 B8 B9 H1 H2 H3 H4 D1 D2 UPS 50-30 F 280 6/10 280 - 140 135 141 UPSD 50-30 F 280 6/10 280 125 60 - - 90 75 - D3 D4 D5 M Ship. vol. Net Gross [m3] 120 122 111 82 251 333 123 50 99 110/125 165 14/19 M12 20.7 22.3 141 360 190 185 100 200 - - 90 251 341 - 50 99 110/125 165 14/19 M12 37.0 40.1 0.034 0.061 * Weights of bronze versions are approx. 10 % higher. 27 Data sheet UPS 50-60/4 F 280, UPSD 50-60/4 F 280 Series 200, 50 Hz UPS 50-60/4 F 280, UPSD 50-60/4 F 280 Inlet pressure H p [kPa] [m] 50 5 40 4 30 3 20 2 tm [°C] 3 Hmin [bar] 2 75 90 120 0.05 0.15 1.45 Electrical data 1 10 3 x 230 V 1 3 x 400-415 V 0 0 0 4 0 1 8 2 12 3 16 4 20 5 24 6 7 28 Q [m³/h] 8 9 Q [l/s] P1 [W] 400 2 300 Pmin [W] I1/1 [A] Cos ϕ Speed 1 240 130 0.75 0.81 Speed 2 290 140 0.87 0.84 Speed 3 430 220 1.60 0.67 Speed 1 240 130 0.43 0.81 Speed 2 290 140 0.50 0.84 Speed 3 430 220 0.92 0.67 Series 200 is also available for 1 x 230-240 V Single-head pumps are available with bronze housing, type B. Eta [%] 40 3 Pmax [W] Energy labelling 30 Energy class 20 Eta 100 10 0 0 0 4 8 12 16 20 24 28 Q [m³/h] B1 3 x 230 V 3 x 400-415 V UPS 50-60/4 F 280 C C UPSD 50-60/4 F 280 D D H3 H2 D4 B7 D2 D1 L3 D5 M Rp 1/4 B4 B8 H4 B3 H3 H2 H1 TM02 0701 3601 L1 B 2 H1 TMA0 9456 0497 Pump type 1 200 D3 B5 B9 D3 B7 B6 D4 B6 D2 TM02 0703 3601 D5 L3 L2 L1 B2 D1 Rp 1/4 B4 D3 M B5 D3 Dimensions and weights Pump type L1 L2 UPS 50-60/4 F 280 6/10 280 - L3 B1 B2 B3 B4 B5 B6 B7 B8 B9 H1 H2 H3 H4 D1 D2 140 135 141 UPSD 50-60/4 F 280 6/10 280 126 60 - - 110 100 - D3 D4 D5 M Ship. vol. Net Gross [m3] 110/ 120 135 135 82 236 318 120 50 99 165 14/19 M12 23.1 24.4 125 0.034 110/ 165 14/19 M12 48.0 51.0 125 0.061 169 450 225 225 120 240 * Weights of bronze versions are approx. 10 % higher. 28 Weights [kg]* Dimensions [mm] PN - - 82 236 318 - 50 102 Data sheet UPS 50-60/2 F 280, UPSD 50-60/2 F 280 Series 200, 50 Hz UPS 50-60/2 F 280, UPSD 50-60/2 F 280 Inlet pressure p [kPa] 60 H [m] tm [°C] 3 Hmin [bar] 6 50 5 40 4 30 3 2 0 120 1.65 Pmax [W] Pmin [W] I1/1 [A] Cos ϕ Speed 1 235 185 0.68 0.87 Speed 2 270 205 0.78 0.87 Speed 3 360 270 1.29 0.70 Speed 1 235 185 0.39 0.87 Speed 2 270 205 0.45 0.87 Speed 3 360 270 0.74 0.70 1 2 1 3 x 400-415 V 0 0 0 4 8 1 2 12 3 16 4 20 5 6 Series 200 is also available for 1 x 230-240 V Q [m³/h] 24 7 P1 [W] Eta [%] 40 3 320 2 240 80 10 0 0 4 8 12 16 20 Energy class Pump type 20 Eta 0 Energy labelling 30 1 160 Single-head pumps are available with bronze housing, type B. 8 Q [l/s] 24 Q [m³/h] H1 3 x 230 V 3 x 400-415 V UPS 50-60/2 F 280 C C UPSD 50-60/2 F 280 D D H3 H2 B1 D4 B7 D2 D1 L3 D5 M Rp 1/4 B4 B8 H4 B3 H3 H2 H1 TM02 0701 3601 L1 B 2 TMA0 9437 0497 10 90 0.35 Electrical data 3 x 230 V 20 75 0.05 D3 B5 B9 D3 B7 B6 D4 B6 D2 TM02 0703 3601 D5 L3 L2 L1 B2 D1 Rp 1/4 B4 D3 M B5 D3 Dimensions and weights Pump type L1 L2 UPS 50-60/2 F 280 Weights [kg]* Dimensions [mm] PN 6/10 280 - L3 B1 B2 B3 B4 B5 B6 B7 B8 B9 H1 H2 H3 H4 D1 D2 140 135 141 UPSD 50-60/2 F 280 6/10 280 125 60 - - 90 75 - D3 D4 D5 M Ship. vol. Net Gross [m3] 110/ 120 122 111 75 253 328 123 50 99 165 14/19 M12 27.7 29.3 125 0.043 110/ 165 14/19 M12 38.7 41.1 125 0.061 141 370 190 180 100 200 - - 75 254 329 - 50 99 * Weights of bronze versions are approx. 10 % higher. 29 Data sheet UPS 50-60/2 F 300 Series 200, 50 Hz UPS 50-60/2 F 300 Inlet pressure p [kPa] 50 H [m] 5 40 4 30 3 20 2 10 1 0 0 tm [°C] 3 Hmin [bar] 75 90 120 0.05 0.35 1.65 2 Electrical data 1 Pmax [W] 3 x 400-415 V Pmin [W] I1/1 [A] Cos ϕ Speed 1 155 115 0.25 0.89 Speed 2 175 125 0.29 0.87 Speed 3 250 170 0.46 0.78 Energy labelling Energy class Pump type 0 4 8 12 16 3 x 400-415 V Q [m³/h] 20 UPS 50-60/2 F 300 0.0 0.8 1.6 2.4 3.2 4.0 4.8 5.6 C Q [l/s] P1 [W] Eta [%] 3 45 2 160 30 1 80 15 Eta 0 0 0 4 8 12 16 20 Q [m³/h] TM0A 9429 0497 240 H3 B1 B7 B 2 D4 H2 H1 D2 L3 TM03 2075 3605 L1 D1 D5 M D3 B4 Rp 1/4 B5 D3 Dimensions and weights Pump type L1 L2 UPS 50-60/2 F 300 30 Weights [kg]* Dimensions [mm] PN 6/10 300 - L3 B1 B2 B3 B4 B5 B6 B7 B8 B9 H1 H2 H3 H4 D1 D2 150 135 141 - 75 75 - 80 - - 68 248 316 - D3 D4 D5 M Ship. vol. Net Gross [m3] 110/ 50 99 165 14/19 M12 21.8 23.4 125 0.034 Data sheet UPS 50-120 F 280, UPSD 180 F 280 Series 200, 50 Hz UPS 50-120 F 280, UPSD 50-120 F 280 Inlet pressure p [kPa] H [m] 80 8 70 7 60 6 50 5 40 4 3 tm [°C] 75 90 120 2 Hmin [bar] 0.4 0.7 1.95 Electrical data 1 3 x 230 V Pmax [W] Pmin [W] I1/1 [A] Cos ϕ Speed 1 450 280 1.43 0.79 Speed 2 530 300 1.63 0.81 30 3 Speed 3 720 380 2.26 0.80 20 2 Speed 1 450 280 0.82 0.79 10 1 Speed 2 530 300 0.94 0.81 Speed 3 720 380 1.30 0.80 0 3 x 400-415 V 0 0 0 4 1 8 2 12 3 16 4 20 5 24 6 7 8 Single-head pumps are available with bronze housing, type B. 9 Q [l/s] P1 [W] Eta [%] 3 600 Series 200 is also available for 1 x 230-240 V. Q [m³/h] 28 Energy labelling 45 2 500 1 30 300 200 15 Eta 100 0 0 0 4 8 12 16 20 24 28 Q [m³/h] B1 3 x 230 V 3 x 400-415 V UPS 50-120 F 280 C C UPSD 50-120 F 280 C C H3 H2 D4 B7 D2 D1 L3 D5 M Rp 1/4 B4 B8 H4 B3 H3 H2 H1 TM02 0701 3601 L1 B 2 H1 Energy class Pump type TMA0 9439 0497 400 D3 B5 B9 D3 B7 B6 D4 B6 D2 TM02 0703 3601 D5 L3 L2 L1 B2 D1 Rp 1/4 B4 B5 D3 M D3 Dimensions and weights Pump type L1 UPS 50-120 F 280 Weights [kg]* Dimensions [mm] PN 6/10 280 L2 - L3 B1 B2 B3 B4 B5 B6 B6 B8 B9 H1 H2 H3 H4 D1 D2 140 145 169 UPSD 50-120 F 280 6/10 280 126 60 - - 100 100 - D3 D4 D5 M Ship. vol. Net Gross [m3] 110/ 120 135 135 75 232 307 116 50 99 165 14/19 M12 24.3 25.4 125 0.034 110/ 165 14/19 M12 46.1 48.1 125 0.061 169 450 225 225 120 240 - - 75 231 306 - 50 99 * Weights of bronze versions are approx. 10 % higher. 31 Data sheet UPS 50-180 F 280, UPSD 180 F 280 Series 200, 50 Hz UPS 50-180 F 280, UPSD 50-180 F 280 Inlet pressure p [kPa] H [m] tm [°C] 3 2 14 120 Hmin [bar] 12 10 80 8 60 6 40 4 20 2 0 3 x 230 V 3 x 400-415 V 0 0 0 90 120 0.65 1.9 Electrical data 1 100 75 0.35 4 1 8 2 12 3 16 4 20 5 24 6 7 8 3 I1/1 [A] Cos ϕ Speed 1 760 360 2.17 0.88 Speed 2 850 380 2.43 0.88 Speed 3 1000 520 3.48 0.72 Speed 1 760 360 1.25 0.88 Speed 2 850 380 1.40 0.88 Speed 3 1000 520 2.00 0.72 Single-head pumps are available with bronze housing, type B. 9 Q [l/s] P1 [W] Pmin [W] Series 200 is also available for 1 x 230-240 V Q [m³/h] 28 Pmax [W] Eta [%] Energy labelling 2 800 40 1 30 Eta 400 20 200 10 0 0 0 4 8 12 16 20 24 28 Q [m³/h] B1 3 x 230 V 3 x 400-415 V UPS 50-180 F 280 C C UPSD 50-180 F 280 C C H3 H2 D4 B7 D2 D1 L3 D5 M Rp 1/4 B4 B8 H4 B3 H3 H2 H1 TM02 0701 3601 L1 B 2 H1 Energy class Pump type TMA0 9441 0497 600 D3 B5 B9 D3 B7 B6 D4 B6 D2 TM02 0703 3601 D5 L3 L2 L1 B2 D1 Rp 1/4 B4 B5 D3 M D3 Dimensions and weights Pump type L1 UPS 50-180 F 280 6/10 280 L2 - L3 B1 B2 B3 B4 B5 B6 B6 B8 B9 H1 H2 H3 H4 D1 D2 140 145 169 UPSD 50-180 F 280 6/10 280 126 60 - - 100 100 - D3 D4 D5 M Ship. vol. Net Gross [m3] 110/ 120 135 135 75 276 351 116 50 99 165 14/19 M12 25.6 26.9 125 0.043 110/ 165 14/19 M12 51.5 58.4 125 0.125 169 450 225 225 120 240 * Weights of bronze versions are approx. 10 % higher. 32 Weights [kg]* Dimensions [mm] PN - - 75 276 351 - 50 99 Data sheet UPS 50-185 F 280 Series 200, 50 Hz UPS 50-185 F 280 Inlet pressure p [kPa] 160 H [m] tm [°C] 3 Hmin [bar] 75 90 120 1.85 1.0 2.15 16 2 120 12 80 8 40 4 0 0 Electrical data Pmax [W] Pmin [W] I1/1 [A] Cos ϕ Speed 1 1150 710 5.60 0.89 Speed 2 1240 770 6.05 0.89 Speed 3 1290 810 6.00 0.93 1 3 x 400-415 V Series 200 is also available for 1 x 230-240 V Energy labelling 0 4 8 12 16 20 24 28Q [m³/h] Energy class Pump type 0 1 2 3 4 5 6 7 3 x 400-415 V 8 Q [l/s] UPS 50-185 F 280 P1 [W] Eta [%] 1600 40 30 3 2 800 20 1 400 10 Eta 0 0 0 4 8 12 16 20 24 28Q [m³/h] B1 H3 H2 D4 B7 D2 D1 L3 D5 M Rp 1/4 B4 B8 H4 TM02 0701 3601 L1 B 2 H1 TMA1 4943 1199 1200 D D3 B5 B9 D3 Dimensions and weights Pump type Weights [kg] Dimensions [mm] PN L1 L2 L3 B1 B2 B3 B4 B5 B6 B6 B8 B9 H1 H2 H3 H4 D1 D2 UPS 50-185 F 280 6/10 280 - 140 145 155 - 91 104 - 96 - - 75 274 349 - D3 D4 D5 M Ship. vol. Net Gross [m3] 50 99 110/125 165 14/19 M12 25.6 26.9 0.043 33 Data sheet UPS 65-30 F 340, UPSD 65-30 F 340 Series 200, 50 Hz UPS 65-30 F 340, UPSD 65-30 F 340 Inlet pressure p [kPa] H [m] 3 2.8 24 2.4 20 2.0 16 1.6 12 1.2 8 0.8 4 0 tm [°C] 75 90 120 Hmin [bar] 0.4 0.7 1.95 Electrical data 2 Pmax [W] 1 3 x 230 V 0.4 3 x 400-415 V 0.0 0 4 0 1 8 2 12 3 16 4 20 5 24 6 7 28 32 Q [m³/h] 8 9 10 Q [l/s] P1 [W] 3 Pmin [W] I1/1 [A] Cos ϕ Speed 1 135 95 0.42 0.81 Speed 2 155 105 0.49 0.80 Speed 3 215 145 0.90 0.60 Speed 1 135 95 0.24 0.81 Speed 2 155 105 0.28 0.80 Speed 3 215 145 0.52 0.60 Series 200 is also available for 1 x 230-240 V Single-head pumps are available with bronze housing, type B. Eta [%] Energy labelling 2 160 30 1 80 20 Eta 40 10 0 0 0 4 8 12 16 20 24 28 32 Q [m³/h] B1 3 x 230 V 3 x 400-415 V UPS 65-30 F 340 C C UPSD 65-30 F 340 D D H3 H2 D4 B7 D2 D1 L3 D5 M Rp 1/4 B4 B8 H4 B3 H3 H2 H1 TM02 0701 3601 L1 B 2 H1 Energy class Pump type TMA0 9443 0497 120 40 D3 B5 B9 D3 B7 B6 D4 B6 D2 TM02 0703 3601 D5 L3 L2 L1 B2 D1 Rp 1/4 B4 B5 D3 M D3 Dimensions and weights Pump type L1 UPS 65-30 F 340 6/10 340 L2 - L3 B1 B2 B3 B4 B5 B6 B7 B8 B9 H1 H2 H3 H4 D1 D2 170 145 169 UPSD 65-30 F 340 6/10 340 153 63 - - 125 100 - D3 D4 D5 M Ship. vol. Net Gross [m3] 130/ 160 156 140 97 244 341 145 65 118 185 14/19 M16 29.3 145 31.2 0.055 130/ 185 14/19 M12 56.5 145 65.1 0.125 169 470 230 240 120 240 * Weights of bronze versions are approx. 10 % higher. 34 Weights [kg]* Dimensions [mm] PN - - 97 243 340 - 65 118 Data sheet UPS 65-60/4 F 340, UPSD 65-60/4 F 340 Series 200, 50 Hz UPS 65-60/4 F 340, UPSD 65-60/4 F 340 Inlet pressure H p [kPa] [m] 50 tm [°C] 3 5 Hmin [bar] 75 90 120 0.55 0.85 2.1 2 Electrical data 40 4 30 3 20 2 10 1 3 x 230 V 1 3 x 400-415 V 0 0 0 0 8 16 2 4 24 6 32 40 8 10 Eta [%] 3 600 I1/1 [A] Cos ϕ Speed 1 380 185 1.18 0.81 Speed 2 440 200 1.39 0.79 Speed 3 660 290 2.35 0.71 Speed 1 380 185 0.68 0.81 Speed 2 440 200 0.80 0.79 Speed 3 660 290 1.35 0.71 Single-head pumps are available with bronze housing, type B. 14 Q [l/s] P1 [W] Pmin [W] Series 200 is also available for 1 x 230-240 V 48 Q [m³/h] 12 Pmax [W] Energy labelling 45 2 200 15 Eta 0 0 0 8 16 24 32 40 48 Q [m³/h] B1 3 x 230 V 3 x 400-415 V UPS 65-60/4 F 340 C C UPSD 65-60/4 F 340 D D H3 H2 D4 B7 D2 D1 L3 D5 M Rp 1/4 B4 B8 H4 B3 H3 H2 H1 TM02 0701 3601 L1 B 2 H1 Energy class Pump type 30 1 TMA0 9445 0497 400 D3 B5 B9 D3 B7 B6 D4 B6 D2 TM02 0703 3601 D5 L3 L2 L1 B2 D1 Rp 1/4 B4 D3 M B5 D3 Dimensions and weights Pump type L1 L2 UPS 65-60/4 F 340 Weights [kg]* Dimensions [mm] PN 6/10 340 - L3 B1 B2 B3 B4 B5 B6 B7 B8 B9 H1 H2 H3 H4 D1 D2 170 145 169 UPSD 65-60/4 F 340 6/10 340 153 63 - - 125 100 - D3 D4 D5 M Ship. vol. Net Gross [m3] 130/ 160 156 140 97 288 385 145 65 118 185 14/19 M16 32.5 34.5 145 0.055 130/ 185 14/19 M12 63.0 69.9 145 0.125 169 470 240 230 120 240 - - 97 288 385 - 65 118 * Weights of bronze versions are approx. 10 % higher. 35 Data sheet UPS 65-60/2 F 340, UPSD 65-60/2 F 340 Series 200, 50 Hz UPS 65-60/2 F 340, UPSD 65-60/2 F 340 Inlet pressure p [kPa] 60 50 H [m] tm [°C] Hmin [bar] 3 6 75 90 120 0.45 0.75 2.0 Electrical data 5 2 40 Pmax [W] Pmin [W] I1/1 [A] Speed 1 330 290 0.97 0.85 Speed 2 370 320 1.11 0.83 Speed 3 490 420 1.83 0.67 Speed 1 330 290 0.56 0.85 Speed 2 370 320 0.64 0.83 Speed 3 490 420 1.05 0.67 4 1 30 3 3 x 230 V 20 10 0 2 1 3 x 400-415 V 0 0 0 8 16 2 4 24 6 32 8 Series 200 is also available for 1 x 230-240 V Q [m³/h] 40 10 Single-head pumps are available with bronze housing, type B. 12 Q [l/s] P1 [W] Cos ϕ Eta [%] Energy labelling 3 400 40 2 30 1 200 20 Eta 100 10 0 0 0 8 16 24 32 40 Q [m³/h] 3 x 400-415 V D D UPSD 65-60/2 F 340 D D D4 B7 D2 D1 L3 D5 M Rp 1/4 B4 B8 H4 B3 H3 H2 H1 TM02 0701 3601 L1 B 2 H1 3 x 230 V UPS 65-60/2 F 340 H3 H2 B1 Energy class Pump type TMA0 9447 0497 300 D3 B5 B9 D3 B7 B6 D4 B6 D2 TM02 0703 3601 D5 L3 L2 L1 B2 D1 Rp 1/4 B4 D3 M B5 D3 Dimensions and weights Pump type L1 L2 UPS 65-60/2 F 340 6/10 340 - L3 B1 B2 B3 B4 B5 B6 B7 B8 B9 H1 H2 H3 H4 D1 D2 170 135 141 UPSD 65-60/2 F 340 6/10 340 153 63 36 Weights [kg]* Dimensions [mm] PN - - 95 75 - D3 D4 D5 M Ship. vol. Net Gross [m3] 130/ 120 126 126 82 262 344 128 65 118 185 14/19 M12 24.3 26.1 145 0.043 130/ 185 14/19 M12 49.0 56.9 145 0.125 141 405 210 195 120 240 - - 82 262 344 - 65 118 Data sheet UPS 65-60/2 F 280 Series 200, 50 Hz UPS 65-60/2 F 280 Inlet pressure p [kPa] 60 50 H [m] tm [°C] Hmin [bar] 3 6 75 90 120 0.45 0.75 2.0 Electrical data 5 2 40 Pmax [W] Pmin [W] I1/1 [A] Cos ϕ Speed 1 235 185 0.39 0.87 Speed 2 270 205 0.45 0.87 Speed 3 360 270 0.74 0.70 4 1 30 3 3 x 400-415 V 20 2 10 1 0 0 Energy labelling Energy class Pump type 0 8 16 24 32 3 x 400-415 V Q [m³/h] 40 UPS 65-60/2 F 280 0 2 4 6 8 10 C 12 Q [l/s] P1 [W] Eta [%] 3 400 40 2 30 1 200 20 Eta 100 10 0 0 0 8 16 24 32 40 Q [m³/h] TMA0 9447 0497 300 H3 B1 B7 B 2 D4 H2 H1 D2 L3 TM03 2075 3605 L1 D1 D5 M D3 B4 Rp 1/4 B5 D3 Dimensions and weights Pump type L1 L2 UPS 65-60/2 F 280 Weights [kg]* Dimensions [mm] PN 6/10 280 - L3 B1 B2 B3 B4 B5 B6 B7 B8 B9 H1 H2 H3 H4 D1 D2 140 135 141 - 87 75 - 120 - - 75 254 329 - D3 D4 D5 M Ship. vol. Net Gross [m3] 130/ 185 14/19 M12 23.0 25.0 65 118 145 0.034 37 Data sheet UPS 65-120 F 280 Series 200, 50 Hz UPS 65-120 F 280 Inlet pressure p [kPa] H [m] 80 8 70 7 60 6 50 5 40 4 30 3 20 2 10 1 0 0 3 tm [°C] 75 90 120 2 Hmin [bar] 0.9 1.2 2.45 Electrical data 1 3 x 400-415 V Pmax [W] Pmin [W] I1/1 [A] Cos ϕ Speed 1 450 280 0.82 0.79 Speed 2 530 300 0.94 0.81 Speed 3 720 380 1.30 0.80 Energy labelling Energy class Pump type 0 4 8 12 16 20 24 3 x 400-415 V Q [m³/h] 28 UPS 65-120 F 280 0 1 2 3 4 5 6 7 8 P1 [W] Eta [%] 3 600 C 9 Q [l/s] 45 2 500 1 30 TMA0 9439 0497 400 300 200 Eta 100 0 15 0 0 4 8 12 16 20 24 28 Q [m³/h] H3 B1 B7 B 2 D4 H2 H1 D2 L3 TM03 2075 3605 L1 D1 D5 M D3 B4 Rp 1/4 B5 D3 Dimensions and weights Pump type L1 UPS 65-120 F 280 38 Weights [kg]* Dimensions [mm] PN 6/10 280 L2 - L3 B1 B2 B3 B4 B5 B6 B7 B8 B9 H1 H2 H3 H4 D1 D2 140 145 169 - 100 100 - 120 - - 75 236 311 - D3 D4 D5 M Ship. vol. Net Gross [m3] 130/ 65 118 185 14/19 M12 25.6 27.1 145 0.043 Data sheet UPS 65-120 F 340, UPSD 65-120 F 340 Series 200, 50 Hz UPS 65-120 F 340, UPSD 65-120 F 340 Inlet pressure p [kPa] H [m] 100 10 80 8 60 6 40 4 20 3 2 tm [°C] 75 90 120 Hmin [bar] 0.9 1.2 2.45 Electrical data 1 3 x 230 V 2 3 x 400-415 V 0 0 0 0 8 16 2 4 24 6 32 8 10 12 Eta [%] 3 1 30 20 Eta 200 10 0 0 16 24 32 40 48 Q [m³/h] B1 H1 440 2.35 0.91 900 460 2.52 0.90 Speed 3 1150 600 3.74 0.77 Speed 1 850 440 1.35 0.91 Speed 2 900 460 1.45 0.90 Speed 3 1150 600 2.15 0.77 Energy class 3 x 230 V 3 x 400-415 V UPS 65-120 F 340 C C UPSD 65-120 F 340 C C H3 H2 D4 B7 D2 D1 L3 D5 M Rp 1/4 B4 B8 H4 B3 H3 H2 H1 TM02 0701 3601 L1 B 2 850 Speed 2 Pump type TMA0 9449 0497 400 8 Speed 1 40 600 0 Cos ϕ Energy labelling 2 800 I1/1 [A] Single-head pumps are available with bronze housing, type B. 14 Q [l/s] P1 [W] Pmin [W] Series 200 is also available for 1 x 230-240 V 48 Q [m³/h] 40 Pmax [W] D3 B5 B9 D3 B7 B6 D4 B6 D2 TM02 0703 3601 D5 L3 L2 L1 B2 D1 Rp 1/4 B4 B5 D3 M D3 Dimensions and weights Pump type L1 UPS 65-120 F 340 Weights [kg]* Dimensions [mm] PN 6/10 340 L2 - L3 B1 B2 B3 B4 B5 B6 B7 B8 B9 H1 H2 H3 H4 D1 D2 170 145 169 UPSD 65-120 F 340 6/10 340 153 63 - - 100 100 - D3 D4 D5 M Ship. vol. Net Gross [m3] 130/ 120 140 140 82 285 367 127 65 118 185 14/19 M12 27.4 28.8 145 0.043 130/ 185 14/19 M12 53.0 60.0 145 0.125 169 450 225 225 120 240 - - 82 286 368 - 65 118 * Weights of bronze versions are approx. 10 % higher. 39 Data sheet UPS 65-180 F 340, UPSD 65-180 F 340 Series 200, 50 Hz UPS 65-180 F 340, UPSD 65-180 F 340 Inlet pressure H p [kPa] [m] 14 120 12 100 10 80 8 60 6 40 4 20 0 3 tm [°C] 75 90 120 2 Hmin [bar] 0.7 1.0 2.25 Electrical data 1 3 x 230 V 2 3 x 400-415 V 0 0 0 8 16 2 4 24 6 32 8 40 10 3 800 30 400 TMA0 9450 0497 Eta 15 0 0 16 24 32 40 48 Q [m³/h] B1 H1 1100 520 3.22 0.86 Speed 2 1200 560 3.48 0.87 Speed 3 1550 740 5.04 0.77 Speed 1 1100 520 1.85 0.86 Speed 2 1200 560 2.00 0.87 Speed 3 1550 740 2.90 0.77 Energy class 3 x 230 V 3 x 400-415 V UPS 65-180 F 340 C C UPSD 65-180 F 340 C C H3 H2 D4 B7 D2 D1 L3 D5 M Rp 1/4 B4 B8 H4 B3 H3 H2 H1 TM02 0701 3601 L1 B 2 Speed 1 Pump type 45 1 8 Cos ϕ Energy labelling Eta [%] 2 0 I1/1 [A] 14 Q [l/s] P1 [W] 1200 Pmin [W] Single-head pumps are available with bronze housing, type B. 48 Q [m³/h] 12 Pmax [W] D3 B5 B9 D3 B7 B6 D4 B6 D2 TM02 0703 3601 D5 L3 L2 L1 B2 D1 Rp 1/4 B4 D3 M B5 D3 Dimensions and weights Pump type L1 L2 UPS 65-180 F 340 6/10 340 - L3 B1 B2 B3 B4 B5 B6 B6 B8 B9 H1 H2 H3 H4 D1 D2 170 145 169 UPSD 65-180 F 340 6/10 340 153 63 - - 100 100 - D3 D4 D5 M Ship. vol. Net Gross [m3] 130/ 120 140 140 82 285 367 127 65 118 185 14/19 M12 29.3 33.1 145 0.043 130/ 185 14/19 M12 70.0 76.9 145 0.125 169 450 225 225 120 240 * Weights of bronze versions are approx. 10 % higher. 40 Weights [kg]* Dimensions [mm] PN - - 82 286 368 - 65 118 Data sheet UPS 65-185 F 340 Series 200, 50 Hz UPS 65-185 F 340 Inlet pressure p [kPa] H [m] tm [°C] 3 160 Hmin [bar] 75 90 120 0.90 1.30 2.35 16 2 12 80 8 40 4 0 0 Pmax [W] Pmin [W] I1/1 [A] Cos ϕ Speed 1 1220 825 2.00 0.88 Speed 2 1340 860 2.20 0.88 Speed 3 1710 1100 3.25 0.76 1 3 x 400-415 V 0 0 8 16 2 4 24 6 32 8 40 Energy labelling Q [m³/h] 10 12 Q [l/s] P1 [W] 1600 2 1200 20 400 10 Eta 0 0 0 8 16 24 32 40 Q [m³/h] B1 H1 C H3 H2 D4 B7 D2 D1 L3 D5 M Rp 1/4 B4 B8 H4 TM02 0701 3601 L1 B 2 3 x 400-415 V C 30 1 800 3 x 230 V UPS 65-185 F 340 40 3 Energy class Pump type Eta [%] TMA1 4944 1199 120 Electrical data D3 B5 B9 D3 Dimensions and weights Pump type Weights [kg] Dimensions [mm] PN L1 L2 L3 B1 B2 B3 B4 B5 B6 B7 B8 B9 H1 H2 H3 H4 D1 D2 UPS 65-185 F 340 6/10 340 - 170 145 155 - 128 100 - 96 - - 82 282 364 - D3 D4 D5 M Ship. vol. Net Gross [m3] 65 118 130/145 185 14/19 M12 31.8 33.7 0.055 41 Data sheet UPS 80-30 F 360, UPSD 80-30 F 360 Series 200, 50 Hz UPS 80-30 F 360, UPSD 80-30 F 360 Inlet pressure 24 2.4 20 2.0 16 1.6 12 1.2 8 0.8 tm [°C] 3 Hmin [bar] 2 75 90 120 1.15 1.45 2.7 Electrical data Pmax [W] Pmin [W] I1/1 [A] Cos ϕ Speed 1 240 230 0.87 0.69 Speed 2 260 250 1.01 0.65 Speed 3 330 320 2.00 0.41 Speed 1 240 230 0.50 0.69 Speed 2 260 250 0.58 0.65 Speed 3 330 320 1.15 0.41 1 4 0.4 0 0.0 3 x 230 V 3 x 400-415 V 0 0 8 16 2 4 24 32 6 8 40 10 48 12 Single-head pumps are available with bronze housing, type B. Q [m³/h] 14 16 Q [l/s] P1 [W] 3 320 Energy labelling Eta [%] 40 Energy class Pump type 2 240 3 x 230 V 3 x 400-415 V UPS 80-30 F 360 D D UPSD 80-30 F 360 D D 30 1 20 TMA0 9451 0497 160 Eta 80 10 0 0 0 8 16 24 32 40 48 Q [m³/h] H3 H2 D4 D3 D1 B7 L3 B1 D5 M Rp 1/4 B5 B4 B8 H4 B3 H1 D2 L1 B 2 H1 TM02 0697 3601 H p [kPa] [m] 2.8 H3 H2 PN 6 PN 10 B9 D4 B7 B6 B6 D3 TM02 0815 3601 D2 D5 L3 L2 L1 B2 D1 Rp 1/4 B4 M B5 PN 6 PN 10 Dimensions and weights Pump type L1 L2 L3 B1 B2 B3 B4 B5 B6 B7 B8 B9 H1 H2 H3 H4 D1 D2 D3 D4 D5 M Ship. vol. Net Gross [m3] UPS 80-30 F 360 6 360 - 180 145 169 - 130 100 - 160 168 145 107 316 423 160 80 132 150 200 4x19 M16 38.0 39.9 0.055 UPS 80-30 F 360 10 360 - 180 145 169 - 130 100 - 160 168 145 107 316 423 160 80 132 160 200 8x19 M16 38.0 39.9 0.055 UPSD 80-30 F 360 6 360 173 53 - 169 470 240 230 120 240 - - 107 316 423 - 80 132 150 200 4x19 M12 71.0 78.8 0.200 UPSD 80-30 F 360 10 360 173 53 - 169 470 240 230 120 240 - - 107 316 423 - 80 132 160 200 8x19 M12 71.0 78.8 0.200 * Weights of bronze versions are approx. 10 % higher. 42 Weights [kg]* Dimensions [mm] PN Data sheet UPS 80-60 F 360, UPSD 80-60 F 360 Series 200, 50 Hz UPS 80-60 F 360, UPSD 80-60 F 360 Inlet pressure 50 5 40 4 30 3 20 2 3 2 tm [°C] 75 90 120 Hmin [bar] 1.2 1.5 2.75 Electrical data Pmax [W] Pmin [W] I1/1 [A] Cos ϕ Speed 1 470 320 1.46 0.81 Speed 2 570 350 1.74 0.82 Speed 3 880 490 3.13 0.71 Speed 1 470 320 0.84 0.81 Speed 2 570 350 1.00 0.82 Speed 3 880 490 1.80 0.71 1 10 3 x 230 V 1 3 x 400-415 V 0 0 0 0 10 20 2 4 6 30 40 8 10 50 12 14 60 16 Single-head pumps are available with bronze housing, type B. Q [m³/h] 18 20 Q [l/s] P1 [W] Energy labelling Eta [%] 3 Energy class Pump type 800 3 x 230 V 3 x 400-415 V UPS 80-60 F 360 C C UPSD 80-60 F 360 D D 40 2 30 1 400 Eta TMA0 9452 0497 600 20 200 10 0 0 0 10 20 30 40 50 60 Q [m³/h] H3 H2 D4 D3 D1 B7 L3 B1 D5 M Rp 1/4 B5 B4 B8 H4 B3 H1 D2 L1 B 2 H1 TM02 0697 3601 H p [kPa] [m] H3 H2 PN 6 PN 10 B9 D4 B7 B6 B6 D3 TM02 0815 3601 D2 D5 L3 L2 L1 B2 D1 Rp 1/4 B4 M B5 PN 6 PN 10 Dimensions and weights Pump type Weights [kg]* Dimensions [mm] PN L1 L2 L3 B1 B2 B3 B4 B5 B6 B7 B8 B9 H1 H2 H3 H4 D1 D2 D3 D4 D5 M Ship. vol. Net Gross [m3] UPS 80-60 F 360 6 360 - 180 145 169 - 135 100 - 160 165 145 107 295 402 160 80 132 150 200 4x19 M16 37.3 39.2 0.055 UPS 80-60 F 360 10 360 - 180 145 169 - 135 100 - 160 165 145 107 295 402 160 80 132 160 200 8x19 M16 37.0 39.0 0.055 UPSD 80-60 F 360 6 360 173 53 - 169 490 250 240 120 240 - - 107 294 401 - 80 132 150 200 4x19 M12 73.0 80.7 0.200 UPSD 80-60 F 360 10 360 173 53 - 169 490 250 240 120 240 - - 107 294 401 - 80 132 160 200 8x19 M12 73.0 80.7 0.200 * Weights of bronze versions are approx. 10 % higher. 43 Data sheet UPS 80-120 F 360, UPSD 80-120 F 360 Series 200, 50 Hz UPS 80-120 F 360, UPSD 80-120 F 360 Inlet pressure 100 3 10 2 80 8 60 6 40 4 20 tm [°C] 75 90 120 Hmin [bar] 1.6 1.9 3.15 Electrical data 1 Pmax [W] 3 x 230 V 2 3 x 400-415 V 0 0 0 0 10 20 2 4 30 6 8 40 10 50 12 14 60 16 Speed 1 1000 710 2.87 0.87 Speed 2 1100 760 3.13 0.88 Speed 3 1500 960 4.78 0.79 Speed 1 1000 710 1.65 0.87 Speed 2 1100 760 1.80 0.88 Speed 3 1500 960 2.75 0.79 Energy labelling Eta [%] 3 1200 Energy class Pump type 45 3 x 230 V 3 x 400-415 V UPS 80-120 F 360 C C UPSD 80-120 F 360 C C 2 Eta 400 TMA0 9453 0497 30 1 15 0 0 0 10 20 30 40 50 60 Q [m³/h] H3 H2 D4 D3 D1 B7 L3 D5 M B1 B5 B4 B8 H4 B3 H3 H2 H1 D2 L1 B 2 H1 Rp 1/4 Cos ϕ 20 Q [l/s] P1 [W] 800 I1/1 [A] Single-head pumps are available with bronze housing, type B. Q [m³/h] 18 Pmin [W] TM02 0697 3601 H p [kPa] [m] PN 6 PN 10 B9 D4 B7 B6 B6 D3 TM02 0815 3601 D2 D5 L3 L2 L1 B2 D1 Rp 1/4 B4 M B5 PN 6 PN 10 Dimensions and weights Pump type L1 L2 L3 B1 B2 B3 B4 B5 B6 B7 B8 B9 H1 H2 H3 H4 D1 D2 D3 D4 D5 M Ship. vol. Net Gross [m3] UPS 80-120 F 360 6 360 - 180 145 169 - 125 100 - 160 165 145 97 297 394 160 80 132 150 200 4x19 M16 36.7 38.6 0.055 UPS 80-120 F 360 10 360 - 180 145 169 - 125 100 - 160 165 145 97 297 394 160 80 132 160 200 8x19 M16 36.7 38.6 0.055 UPSD 80-120 F 360 6 360 173 53 - 169 460 235 225 120 240 - - 97 294 391 - 80 132 150 200 4x19 M12 75.5 83.2 0.200 UPSD 80-120 F 360 10 360 173 53 - 169 460 235 225 120 240 - - 97 294 391 - 80 132 160 200 8x19 M12 75.5 83.2 0.200 * Weights of bronze versions are approx. 10 % higher. 44 Weights [kg]* Dimensions [mm] PN Data sheet UPS 100-30 F 450, UPSD 100-30 F 450 Series 200, 50 Hz UPS 100-30 F 450, UPSD 100-30 F 450 Inlet pressure H p [kPa] [m] tm [°C] 3 40 4.0 32 3.2 Hmin [bar] 75 90 120 1.05 1.35 2.6 Electrical data 2.4 16 1.6 8 3 x 230 V 0.8 3 x 400-415 V 0 Pmax [W] Pmin [W] I1/1 [A] Cos ϕ Speed 1 410 380 1.25 0.82 Speed 2 460 430 1.46 0.79 Speed 3 670 610 2.70 0.62 Speed 1 410 380 0.72 0.82 Speed 2 460 430 0.84 0.79 Speed 3 670 610 1.55 0.62 1 0.0 0 0 10 2 20 4 6 30 8 40 50 60 70 Single-head pumps are available with bronze housing, type B. Q [m³/h] 10 12 14 16 18 20 22 Q [l/s] P1 [W] Energy labelling Eta 3 600 2 30 1 Eta 200 TMA0 9454 0497 400 15 0 0 0 10 20 30 40 50 60 70 Energy class Pump type 45 Q [m³/h] 3 x 230 V 3 x 400-415 V UPS 100-30 F 450 D D UPSD 100-30 F 450 D D H3 H2 D4 D3 D1 B7 L3 B1 D5 M Rp 1/4 B5 B4 B8 H4 B3 H3 H2 H1 D2 L1 B 2 H1 TM02 0697 3601 24 2 PN 6 PN 10 B9 D4 B7 B6 B6 D3 TM02 0815 3601 D2 D5 L3 L2 L1 B2 D1 Rp 1/4 B4 M B5 PN 6 PN 10 Dimensions and weights Pump type Weights [kg]* Dimensions [mm] PN L1 L2 L3 B1 B2 B3 B4 B5 B6 B7 B8 B9 H1 H2 H3 H4 D1 D2 D3 D4 D5 M Ship. vol. Net Gross [m3] UPS 100-30 F 450 6 450 - 225 145 169 - 175 120 - 200 226 174 122 316 438 186 100 156 170 220 4x19 M16 46.5 49.0 0.087 UPS 100-30 F 450 10 450 - 225 145 169 - 175 120 - 200 226 174 122 316 438 186 100 156 180 220 8x19 M16 46.5 49.0 0.087 UPSD 100-30 F 450 6 450 221 83 - 169 595 280 315 140 280 - - 122 316 438 - 100 156 170 220 4x19 M16 97.4 105.1 0.200 UPSD 100-30 F 450 10 450 221 83 - 169 595 280 315 140 280 - - 122 316 438 - 100 156 180 220 8x19 M16 97.4 105.1 0.200 * Weights of bronze versions are approx. 10 % higher. 45 Accessories Series 200 Accessories Pumps with bronze pump housing The following accessories are available for UPS, UPSD pumps: Pump type Pressure stage UPS 32 • protection module • relay module for single-head pumps PN 10 UPS 40 PN 10 UPS 50 PN 10 UPS 65 PN 10 • relay module kit for twin-head pumps • counter flanges (standard on pumps for the UK) • insulation kit (only single-head pumps) • base plate (only single-head pumps) PN 6 • blanking flanges (only twin-head pumps). UPS 80 Size Product number Rp 1 1/4 96427029 32 mm 96427030 Rp 1 1/2 539711 40 mm 539712 Rp 2 549811 50 mm 549812 Rp 2 1/2 559811 65 mm 559812 Rp 3 96405735 80 mm 569911 Rp 3 569812 Counter flanges PN 10 80 mm 569811 A counter flange kit includes these parts: PN 6 Rp 4 96405737 PN 10 Rp 4 96405738 UPS 100 • two flanges with internal thread (ISO seal thread) or two flanges for welding/soldering Protection modules • two gaskets Voltage [V] • bolts. Product numbers of counter flanges Rp: Flange with internal thread (ISO seal thread). mm: UPS/UPSD 32 PN 10 UPS/UPSD 40 PN 10 UPS/UPSD 50 PN 10 UPS/UPSD 65 PN 10 PN 6 UPS/UPSD 80 PN 10 PN 6 UPS/UPSD 100 PN 10 46 96422220 3 x 400-415 96422221 Relay modules for single-head pumps. Pumps with cast iron pump housing Pressure stage 96422219 3 x 230 Relay module Flange for welding/soldering. Pump type Product number 1 x 230-240 Product number Voltage [V] Rp 1 1/4 539703 1 x 230-240 96406611 32 mm 539704 3 x 230 96406610 Rp 1 1/2 539701 3 x 400-415 96406609 40 mm 539702 Rp 2 549801 Size Product number A relay module kit for twin-head pumps includes these parts: 50 mm 549802 Rp 2 1/2 559801 • two relay modules with screws and screwdriver 65 mm 559802 • two screwed cable entries Rp 3 569902 80 mm 569901 • one intermediate cable Rp 3 569802 80 mm 569801 Rp 4 579901 100 mm 579902 Rp 4 579801 100 mm 579802 • two wiring diagrams for terminal box covers. Voltage [V] Product number 1 x 230-240 96409231 3 x 230 96409230 3 x 400-415 96409229 Accessories Series 200 Insulation kits Base plate Single-head pumps can be fitted with an insulation covering made of expanded polypropylene, EPP. 235 35 195 The insulation kit, which is tailored to the individual pump type, has an insulating thickness corresponding to the nominal diameter of the pump. 2xø18 TM00 9835 0197 The insulation kit encloses the entire pump housing. It consists of two or three parts which are easily fitted around the pump. 2xø14 160 195 80 2xø14 The thermal conductivity of EPP is very low (0.04 W/ m°C), i.e. the insulating property is very good. 2xø18 4xø14 120 200 Fig. 21 Base plate Product numbers of base plates TM02 1406 0702 Pump type Fig. 20 Insulation kit Product numbers of insulation kits UPS UPS UPS UPS Product number* 32-30, -60, -120 40-30, -60/4, -60/2, -120, -180 50-30, -60/4, -60/2, -120, -180 65-60/2, -120, -180 UPS 65-30, -60/4 UPS 80-30, -60, -120 UPS 100-30 96405915 96405914 UPS 40-185 UPS 50-185 UPS 65-185 495035 * Product numbers include a base plate and two bolts. Pump type Product number UPS 32-30 F 220 96405871 UPS 32-60 F 220 96405873 UPS 32-120 F 220 96405873 UPS 40-30 F 250 96405874 UPS 40-60/4 F 250 96405875 UPS 40-60/2 F 250 96405877 UPS 40-120 F 250 96405877 UPS 40-180 F 250 96405878 UPS 50-30 F 280 96405879 UPS 50-60/4 F 280 96405880 UPS 50-60/2 F 280 96405881 UPS 50-120 F 280 96405882 UPS 50-180 F 280 96405883 UPS 65-30 F 340 96405884 UPS 65-60/4 F 340 96405885 UPS 65-60/2 F 340 96405886 UPS 65-120 F 340 96405887 UPS 65-180 F 340 96405888 UPS 80-30 F 360 96405889 UPS 80-60 F 360 96405890 UPS 80-120 F 360 96405891 UPS 100-30 F 450 96405892 Only available for single-head pumps. 47 Accessories Blanking flanges For twin-head pumps a blanking flange with pump housing seal is available as an optional extra. The blanking flange is used when servicing one of the power heads to enable uninterrupted operation of the other. Product number of blanking flanges Pump type Product number UPSD 32-30 F 220 UPSD 32-60 F 220 UPSD 32-120 F 220 UPSD 40-30 F 250 UPSD 40-60 F 250 545048 UPSD 40-60/2 F 250 UPSD 40-120 F 250 UPSD 50-30 F 280 UPSD 50-60/4 F 280 565055 UPSD 50-60/2 F 280 545048 UPSD 50-120 F 280 UPSD 50-180 F 280 UPSD 65-30 F 340 565055 UPSD 65-60/4 F 340 UPSD 65-60/2 F 340 545048 UPSD 65-120 F 340 UPSD 65-180 F 340 UPSD 80-30 F 360 UPSD 80-60 F 360 UPSD 80-120 F 360 UPSD 100-30 F 450 48 565055 Series 200 Further product documentation Series 200 WebCAPS WebCAPS is a Web-based Computer Aided Product Selection program available on www.grundfos.com. WebCAPS contains detailed information on more than 185,000 Grundfos products in more than 20 languages. In WebCAPS, all information is divided into 6 sections: • Catalogue • Literature • Service • Sizing • Replacement • CAD drawings. Catalogue This section is based on fields of application and pump types, and contains • technical data • curves (QH, Eta, P1, P2, etc) which can be adapted to the density and viscosity of the pumped liquid and show the number of pumps in operation • product photos • dimensional drawings • wiring diagrams • quotation texts, etc. Literature In this section you can access all the latest documents of a given pump, such as • data booklets • installation and operating instructions • service documentation, such as Service kit catalogue and Service kit instructions • quick guides • product brochures. Service This section contains an easy-to-use interactive service catalogue. Here you can find and identify service parts of both existing and discontinued Grundfos pumps. Furthermore, this section contains service videos showing you how to replace service parts. 49 Further product documentation Series 200 Sizing 0 1 This section is based on different fields of application and installation examples, and gives easy step-by-step instructions in how to • select the most suitable and efficient pump for your installation • carry out advanced calculations based on energy consumption, payback periods, load profiles, life cycle costs, etc. • analyse your selected pump via the built-in life cycle cost tool • determine the flow velocity in wastewater applications, etc. Replacement In this section you find a guide to selecting and comparing replacement data of an installed pump in order to replace the pump with a more efficient Grundfos pump. The section contains replacement data of a wide range of pumps produced by other manufacturers than Grundfos. Based on an easy step-by-step guide, you can compare Grundfos pumps with the one you have installed on your site. When you have specified the installed pump, the guide will suggest a number of Grundfos pumps which can improve both comfort and efficiency. CAD drawings In this section it is possible to download two-dimensional (2D) and three-dimensional (3D) CAD drawings of most Grundfos pumps. These formats are available in WebCAPS: Two-dimensional drawings: • .dxf, wireframe drawings • .dwg, wireframe drawings. Three-dimensional drawings: • .dwg, wireframe drawings (without surfaces) • .stp, solid drawings (with surfaces) • .eprt, E-drawings. WinCAPS WinCAPS is a Windows-based Computer Aided Product Selection program containing detailed information on more than 185,000 Grundfos products in more than 20 languages. The program contains the same features and functions as WebCAPS, but is an ideal solution if no Internet connection is available. WinCAPS is available on CD-ROM and updated once a year. Fig. 22 WinCAPS CD-ROM 50 51 Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence V7124415 0307 Repl. V7124415 0105 GB GRUNDFOS A/S . DK-8850 Bjerringbro . Denmark Telephone: +45 87 50 14 00 www.grundfos.com Subject to alterations.