Gsc13 Energy-efficient Split System Air Conditioner 13 Seer / R-22

   EMBED


Share

Transcript

GSC13 Energy-Efficient Split System Air Conditioner 13 SEER / R-22 1½ to 5 Tons Contents Nomenclature......................................... 2 Product Specifications............................ 3 Expanded Cooling Data ......................... 4 AHRI Ratings ........................................ 18 Wiring Diagram .................................... 19 Dimensions........................................... 20 Accessories........................................... 20 Standard Features • • • • • • • • • • Energy-efficient compressor Quiet condenser fan system Factory-installed liquid-line filter drier Copper tube/aluminum fin coil For use with R-22 refrigerant; charged with inert gas for shipping R-22 piston kit included Brass liquid and suction service valves with sweat connections Contactor with lug connections Ground lug connection ETL Listed Cabinet Features • Heavy-gauge galvanized-steel cabinet with louver design sound control top • Steel louver coil guard • Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval • When properly anchored, meets the 2010 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.) * Complete warranty details available from your local dealer or at www.goodmanmfg.com. SS-GSC13 www.goodmanmfg.com 4/16 Supersedes 5/15 Nomenclature   G S C 13 036 1 A A 1 2 3 4,5 6,7,8 9 10 11 Brand V GMC  Brand Engineering Major  &  Minor  Revisions (not  used  for  inventory  or  ordering) Product  Category S Split  System   Unit  Type C Condenser  R-­‐410A H Heat  Pump  R-­‐410A Efficiency 13 13  SEER 14 14  SEER 2 16        16  SEER 18        18  SEER 1 2 3 018        1½  Tons 019        1½  Tons 024        2  Tons 025        2  Tons www.goodmanmfg.com Electrical 208/230  V,  1  Phase,  60  Hz 220/240  V,  1  Phase,  50  Hz 208/230  V,  3  Phase,  60  Hz 030        2½  Tons 031        2½  Tons 036        3  Tons 037        3  Tons Nominal  Capacity 042        3½  Tons 043        3½  Tons 048          4  Tons 060          5  Tons SS-GSC13 Product Specifications GSC13 0181G* GSC13 0241F* GSC13 0301E* GSC13 0361G* GSC13 0421C* GSC13 0481C* GSC13 0601D* Cooling Capacities Tonnage 1½ 2 2½ 3 3½ 4 5 Decibels 76 76 72 75 76 76 77 RLA 6.8 10.8 13.5 13.4 15.4 19.2 21.8 LRA 40 56 68 74 87 112 137 Horsepower 1/8 1/8 1/8 1/6 ¼ ¼ ¼ FLA 0.65 0.65 0.7 1.1 1.5 1.5 1.5 Liquid Line Size (“O.D.) ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" Suction Line Size (“O.D.) ¾" ¾" ¾" ⅞" 1⅛" 1⅛" 1⅛" Liquid Valve Size (“O.D.) ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" Suction Valve Size (“O.D.) ³ ¾" ¾" ¾" ¾" ³ ¾" ³ ⅞" 4 ⅞" 4 Sweat Sweat Sweat Sweat Sweat Sweat Sweat 87 77 66 77 108 128 118 208/230-60 208/230-60 208/230-60 208/230-60 208/230-60 208/230-60 208/230-60 9.2 14.2 17.6 17.9 20.8 25.5 28.8 Compressor Condenser Fan Motor Refrigeration System Refrigerant Line Size Refrigerant Connection Size Valve Type Refrigerant Charge Electrical Data AC Volts-Hz Min. Circuit Ampacity¹ Max. Overcurrent Device² 15 25 30 30 35 40 50 Min / Max Volts 197/253 197/253 197/253 197/253 197/253 197/253 197/253 Electrical Conduit Size ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" Equipment Weight (lbs) 104 107 120 158 158 159 174 Ship Weight (lbs) 121 122 137 176 176 177 192 ¹ ² ³ ⁴ Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes Must use time-delay fuses or HACR-type circuit breakers of the same size as noted. Installer will need to supply ¾” to ⅞” adapters for suction line connections. Installer will need to supply ⅞” to 1⅛” adapters for suction line connections. Notes • Always check the S&R plate for electrical data on the unit being installed. • Charge with refrigerant charge listed on S&R plate; 15’ of ⅜” line included in this charge. System charge must be adjusted per Installation Instructions Final Charge Procedure. SS-GSC13 www.goodmanmfg.com 3 4 Airflow MBh S/T ∆T kW 525 Amps HI PR LO PR MBh S/T ∆T kW 600 Amps HI PR LO PR MBh S/T ∆T 675 kW Amps HI PR LO PR 59 15.8 0.69 19 1.01 4.2 130 59 17.1 0.72 19 1.04 4.3 134 61 17.6 0.75 18 1.05 4.4 135 61 63 16.4 0.58 17 1.03 4.3 140 63 17.7 0.60 16 1.06 4.4 144 65 18.3 0.63 16 1.07 4.5 146 65 67 17.9 0.40 13 1.07 4.5 148 68 19.4 0.42 12 1.10 4.6 152 71 20.0 0.44 12 1.11 4.6 154 71 71 - 59 15.4 0.72 19 1.10 4.6 146 62 16.7 0.74 19 1.13 4.7 150 64 17.2 0.78 18 1.14 4.7 152 65 63 16.0 0.60 17 1.12 4.7 157 66 17.3 0.62 17 1.15 4.8 162 68 17.9 0.65 16 1.17 4.8 164 69 75 67 17.5 0.42 13 1.16 4.8 166 72 19.0 0.43 13 1.20 4.9 171 75 19.6 0.45 12 1.21 5.0 173 75 MBh 16.1 16.5 17.9 19.2 15.7 16.2 17.5 S/T 0.79 0.70 0.53 0.34 0.82 0.73 0.55 ∆T 22 20 17 12 22 21 17 kW 1.02 1.04 1.08 1.12 1.11 1.13 1.17 525 Amps 4.3 4.4 4.5 4.7 4.6 4.7 4.8 HI PR 131 141 149 156 147 159 168 LO PR 59 63 69 74 63 67 73 MBh 17.4 17.9 19.4 20.8 17.0 17.5 19.0 S/T 0.82 0.73 0.55 0.36 0.85 0.76 0.57 ∆T 22 20 16 11 22 20 17 600 75 kW 1.05 1.07 1.11 1.15 1.14 1.17 1.21 Amps 4.4 4.5 4.6 4.8 4.7 4.8 5.0 HI PR 135 146 154 161 152 164 173 LO PR 61 65 71 76 65 69 75 MBh 17.9 18.5 20.0 21.5 17.5 18.0 19.5 S/T 0.86 0.77 0.58 0.37 0.89 0.79 0.60 ∆T 21 19 16 11 21 20 16 kW 1.06 1.08 1.12 1.16 1.15 1.18 1.22 675 Amps 4.4 4.5 4.7 4.8 4.8 4.9 5.0 HI PR 137 147 155 162 154 165 174 LO PR 62 66 72 77 65 70 76 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 70 IDB 65 18.8 0.36 12 1.22 5.0 175 78 20.3 0.37 11 1.25 5.1 180 80 21.0 0.39 11 1.26 5.2 182 81 71 15.3 0.84 22 1.19 5.0 168 65 16.6 0.87 22 1.22 5.1 173 67 17.1 0.91 21 1.23 5.1 175 68 59 15.1 0.74 19 1.17 4.9 166 65 16.3 0.76 19 1.21 5.0 171 67 16.8 0.80 18 1.22 5.1 173 67 71 - 59 14.0 0.79 19 1.30 5.5 213 71 15.1 0.82 19 1.34 5.7 219 73 15.6 0.86 18 1.35 5.7 221 74 63 14.5 0.66 17 1.33 5.7 229 76 15.7 0.68 16 1.37 5.8 236 78 16.2 0.72 16 1.38 5.9 238 79 67 15.9 0.46 13 1.38 5.9 242 83 17.2 0.47 12 1.42 6.0 249 85 17.7 0.50 12 1.43 6.1 252 86 105 71 - 59 12.9 0.80 18 1.35 5.9 235 74 14.0 0.82 18 1.39 6.0 242 76 14.4 0.86 17 1.40 6.1 245 77 63 13.4 0.66 16 1.38 6.0 253 78 14.5 0.69 15 1.42 6.2 261 81 15.0 0.72 15 1.44 6.2 263 82 67 14.7 0.46 12 1.43 6.2 267 86 15.9 0.48 12 1.47 6.4 275 88 16.4 0.50 11 1.49 6.4 278 89 115 71 - 17.1 18.3 15.0 15.4 16.7 17.9 14.2 14.6 15.8 17.0 13.2 13.5 14.7 15.7 0.57 0.36 0.86 0.77 0.58 0.38 0.90 0.80 0.61 0.39 0.90 0.81 0.61 0.39 17 12 23 21 17 12 22 21 17 12 21 19 16 11 1.26 1.30 1.25 1.28 1.33 1.38 1.31 1.34 1.39 1.44 1.36 1.40 1.45 1.50 5.2 5.4 5.3 5.4 5.6 5.8 5.6 5.7 5.9 6.1 5.9 6.0 6.2 6.5 191 199 191 206 217 226 215 231 244 255 237 255 270 281 76 81 69 73 80 85 72 77 84 89 74 79 86 92 18.5 19.9 16.2 16.7 18.1 19.4 15.4 15.8 17.2 18.4 14.3 14.7 15.9 17.1 0.59 0.38 0.90 0.80 0.61 0.39 0.93 0.83 0.63 0.40 0.94 0.84 0.63 0.41 17 12 22 20 17 12 22 20 17 11 20 19 15 11 1.29 1.34 1.29 1.32 1.37 1.42 1.35 1.38 1.43 1.49 1.40 1.44 1.49 1.54 5.4 5.6 5.4 5.5 5.7 5.9 5.7 5.9 6.1 6.3 6.1 6.2 6.4 6.6 196 205 197 212 224 233 222 238 252 263 245 263 278 290 78 83 71 75 82 88 74 79 86 92 77 82 89 95 19.1 20.5 16.7 17.2 18.6 20.0 15.9 16.3 17.7 19.0 14.7 15.1 16.4 17.6 0.62 0.40 0.94 0.84 0.64 0.41 0.97 0.87 0.66 0.42 0.98 0.88 0.67 0.43 16 11 21 20 16 11 21 19 16 11 20 18 15 10 1.30 1.35 1.30 1.33 1.38 1.43 1.36 1.39 1.45 1.50 1.41 1.45 1.50 1.56 5.4 5.6 5.5 5.6 5.8 6.0 5.8 5.9 6.1 6.3 6.1 6.3 6.5 6.7 198 207 199 214 226 236 224 241 254 265 247 266 281 293 79 84 71 76 83 88 75 80 87 93 77 82 90 96 Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan) kW = Total system power Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions 15.8 0.75 21 1.21 5.1 180 70 17.1 0.78 20 1.25 5.2 186 72 17.6 0.81 20 1.26 5.3 188 72 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 15.6 17.1 14.7 15.2 16.7 0.61 0.43 0.76 0.63 0.44 17 13 20 17 13 1.20 1.25 1.24 1.27 1.32 5.0 5.2 5.2 5.4 5.5 179 189 189 203 215 69 75 68 72 79 16.9 18.5 15.9 16.5 18.1 0.64 0.44 0.79 0.66 0.46 17 13 19 17 13 1.24 1.28 1.28 1.31 1.36 5.2 5.3 5.4 5.5 5.7 184 194 195 210 221 71 77 70 75 81 17.4 19.1 16.4 17.0 18.6 0.67 0.46 0.83 0.69 0.48 16 12 18 16 12 1.25 1.29 1.29 1.32 1.37 5.2 5.4 5.4 5.5 5.7 186 196 197 212 224 72 78 71 75 82 Expanded Cooling Data — GSC130181G* www.goodmanmfg.com SS-GSC13 SS-GSC13 Airflow 59 MBh 16.4 S/T 0.86 ∆T 25 kW 1.03 525 Amps 4.3 HI PR 133 LO PR 60 MBh 17.7 S/T 0.90 ∆T 24 kW 1.06 600 Amps 4.4 HI PR 137 LO PR 62 MBh 18.3 S/T 0.94 ∆T 23 675 kW 1.07 Amps 4.5 HI PR 138 LO PR 63 63 16.7 0.81 24 1.05 4.4 143 64 18.1 0.84 23 1.08 4.5 147 66 18.7 0.88 22 1.09 4.6 149 67 67 71 17.9 19.1 0.66 0.5 21 16 1.09 1.1 4.5 4.7 151 157.3 70 74.3 19.4 20.7 0.68 0.5 20 16 1.12 1.2 4.7 4.8 155 162.2 72 76.6 19.9 21.3 0.72 0.5 19 16 1.13 1.2 4.7 4.9 157 163.8 73 77.4 59 16.0 0.90 25 1.12 4.6 149 63 17.3 0.93 25 1.15 4.8 154 65 17.8 1.00 24 1.16 4.8 155 66 63 16.3 0.84 24 1.14 4.7 160 68 17.7 0.87 24 1.18 4.9 165 70 18.2 0.91 23 1.19 4.9 167 70 75 67 17.4 0.68 21 1.19 4.9 169 74 18.9 0.71 21 1.22 5.0 174 76 19.5 0.74 20 1.23 5.1 176 77 MBh 16.6 17.0 17.8 19.0 16.3 16.6 17.4 S/T 0.91 0.87 0.79 0.64 0.94 0.91 0.82 ∆T 26 26 25 21 27 26 25 kW 1.04 1.06 1.10 1.14 1.13 1.15 1.20 525 Amps 4.3 4.4 4.6 4.7 4.7 4.8 4.9 HI PR 134 144 152 159 150 162 171 LO PR 61 65 71 75 64 68 74 MBh 18.0 18.4 19.3 20.5 17.6 18.0 18.8 S/T 0.94 0.91 0.82 0.66 0.97 0.94 0.85 ∆T 26 26 24 21 26 26 24 600 85 kW 1.07 1.09 1.13 1.17 1.16 1.19 1.23 Amps 4.5 4.6 4.7 4.9 4.8 4.9 5.1 HI PR 138 149 157 164 155 167 176 LO PR 63 67 73 77 66 70 77 MBh 18.6 18.9 19.8 21.2 18.1 18.5 19.4 S/T 0.98 0.95 0.86 0.70 1.00 0.98 0.89 ∆T 25 25 23 20 25 25 23 kW 1.08 1.10 1.14 1.18 1.17 1.20 1.24 675 Amps 4.5 4.6 4.7 4.9 4.8 4.9 5.1 HI PR 140 150 159 165 157 169 178 LO PR 63 67 73 78 67 71 78 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 80 IDB 65 18.5 0.66 21 1.24 5.1 178 79 20.1 0.69 21 1.27 5.2 184 82 20.7 0.72 20 1.29 5.3 186 83 71 18.6 0.51 17 1.23 5.1 177 79 20.2 0.53 16 1.26 5.2 182 81 20.8 0.56 16 1.27 5.2 184 82 15.9 0.96 27 1.21 5.0 171 67 17.2 1.00 26 1.24 5.2 176 69 17.7 1.00 24 1.25 5.2 178 69 59 15.6 0.92 25 1.20 5.0 169 66 16.9 0.95 25 1.23 5.1 175 68 17.4 1.00 24 1.24 5.2 176 69 71 17.8 0.54 17 1.39 5.8 229 86 19.2 0.56 17 1.43 6.0 236 88 19.8 0.59 16 1.45 6.0 238 89 59 14.5 0.98 25 1.32 5.6 217 73 15.7 1.00 24 1.36 5.8 224 75 16.1 1.00 22 1.37 5.8 226 76 63 14.8 0.92 24 1.36 5.8 234 77 16.0 0.96 23 1.40 5.9 241 80 16.5 1.00 22 1.41 6.0 243 80 67 15.8 0.75 21 1.41 6.0 247 84 17.1 0.78 20 1.45 6.1 254 87 17.6 0.82 20 1.46 6.2 257 88 105 71 16.9 0.6 17 1.5 6.2 257.2 89.9 18.3 0.6 16 1.5 6.3 265.2 92.6 18.8 0.6 16 1.5 6.4 267.8 93.6 59 13.4 0.99 23 1.37 6.0 240 75 14.5 1.00 22 1.41 6.1 247 77 14.9 1.00 20 1.43 6.2 250 78 63 13.7 0.93 22 1.41 6.1 258 80 14.8 0.96 22 1.45 6.3 266 82 15.3 1.00 21 1.46 6.3 269 83 67 14.6 0.76 19 1.46 6.3 272 87 15.8 0.78 19 1.50 6.5 281 90 16.3 0.82 18 1.52 6.5 284 91 115 71 15.6 0.57 15 1.51 6.5 284 93 16.9 0.59 15 1.56 6.7 293 96 17.4 0.62 15 1.57 6.8 296 97 16.9 18.1 15.5 15.8 16.5 17.6 14.7 15.0 15.7 16.8 13.6 13.9 14.5 15.5 0.84 0.68 0.99 0.96 0.86 0.70 1.00 0.99 0.90 0.73 1.00 1.00 0.91 0.73 25 22 27 26 25 22 26 26 25 21 24 24 23 20 1.28 1.33 1.28 1.31 1.36 1.41 1.34 1.37 1.42 1.47 1.39 1.42 1.47 1.53 5.3 5.5 5.4 5.5 5.7 5.9 5.7 5.8 6.0 6.2 6.0 6.2 6.4 6.6 194 203 195 210 221 231 219 236 249 260 242 261 275 287 77 82 70 74 81 87 73 78 85 91 76 81 88 94 18.4 19.6 16.8 17.1 17.9 19.1 15.9 16.2 17.0 18.2 14.8 15.0 15.8 16.8 0.87 0.71 1.00 0.99 0.90 0.73 1.00 1.00 0.93 0.76 1.00 1.00 0.94 0.76 24 21 26 26 25 21 24 25 24 21 23 23 23 20 1.32 1.36 1.31 1.34 1.39 1.45 1.37 1.41 1.46 1.51 1.43 1.46 1.52 1.57 5.5 5.7 5.5 5.6 5.8 6.0 5.8 6.0 6.2 6.4 6.2 6.3 6.5 6.8 200 209 201 216 228 238 226 243 257 268 250 269 284 296 80 85 72 77 84 89 76 80 88 94 78 83 91 97 18.9 20.2 17.3 17.6 18.4 19.7 16.4 16.7 17.5 18.7 15.2 15.5 16.2 17.3 0.91 0.74 1.00 1.00 0.94 0.76 1.00 1.00 0.98 0.79 1.00 1.00 0.98 0.80 23 20 24 24 24 20 22 23 23 20 21 21 22 19 1.33 1.38 1.32 1.36 1.41 1.46 1.39 1.42 1.47 1.53 1.44 1.48 1.53 1.59 5.5 5.7 5.6 5.7 5.9 6.1 5.9 6.0 6.2 6.5 6.2 6.4 6.6 6.8 202 211 203 218 231 240 228 246 259 271 252 271 287 299 81 86 73 78 85 90 76 81 89 94 79 84 92 98 Shaded area reflects AHRI conditions Amps = outdoor unit amps (comp.+fan) kW = Total system power Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions 16.2 0.93 26 1.24 5.2 184 71 17.5 0.96 26 1.27 5.3 190 73 18.1 1.00 25 1.28 5.3 192 74 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 15.9 17.0 18.2 15.2 15.6 16.6 0.86 0.70 0.5 0.95 0.89 0.72 24 21 17 25 24 21 1.22 1.27 1.3 1.27 1.30 1.34 5.1 5.3 5.5 5.3 5.4 5.6 182 192 200.8 193 208 219 70 77 81.6 69 74 81 17.3 18.5 19.7 16.5 16.8 18.0 0.89 0.73 0.5 0.98 0.92 0.75 24 21 16 25 24 21 1.26 1.30 1.4 1.30 1.33 1.38 5.3 5.4 5.6 5.5 5.6 5.8 188 198 207.0 199 214 226 72 79 84.2 71 76 83 17.8 19.0 20.3 17.0 17.4 18.5 0.94 0.76 0.6 1.00 0.97 0.79 23 20 16 23 23 20 1.27 1.32 1.4 1.31 1.34 1.39 5.3 5.5 5.7 5.5 5.6 5.8 190 200 209.0 201 216 228 73 80 85.0 72 77 84 Expanded Cooling Data — GSC130181G* (cont.) www.goodmanmfg.com 5 6 Airflow MBh S/T ∆T kW 700 Amps HI PR LO PR MBh S/T ∆T kW 800 Amps HI PR LO PR MBh S/T ∆T 900 kW Amps HI PR LO PR 59 20.0 0.67 17 1.48 7.0 134 57 21.7 0.69 17 1.52 7.2 138 59 22.3 0.72 17 1.54 7.2 140 59 63 20.8 0.56 15 1.52 7.1 144 61 22.5 0.58 15 1.56 7.3 149 63 23.2 0.60 14 1.58 7.3 150 63 67 22.7 0.38 11 1.57 7.3 152 66 24.6 0.40 11 1.62 7.5 157 68 25.4 0.42 11 1.63 7.5 159 69 71 - 59 19.6 0.69 18 1.61 7.5 150 60 21.2 0.71 17 1.66 7.6 155 62 21.8 0.75 17 1.67 7.7 157 63 63 20.3 0.58 15 1.65 7.6 162 64 22.0 0.60 15 1.70 7.8 167 66 22.6 0.63 14 1.71 7.8 169 67 75 67 22.2 0.40 12 1.71 7.8 171 70 24.1 0.41 11 1.76 8.0 176 72 24.8 0.43 11 1.78 8.1 178 73 MBh 20.4 21.0 22.7 24.4 19.9 20.5 22.2 S/T 0.76 0.68 0.51 0.33 0.78 0.70 0.53 ∆T 20 19 15 11 20 19 15 kW 1.50 1.53 1.59 1.65 1.63 1.67 1.73 700 Amps 7.0 7.2 7.4 7.6 7.5 7.7 7.9 HI PR 135 146 154 161 152 164 173 LO PR 58 61 67 71 61 65 71 MBh 22.1 22.7 24.6 26.4 21.5 22.2 24.0 S/T 0.78 0.70 0.53 0.34 0.81 0.73 0.55 ∆T 20 18 15 10 20 19 15 800 75 kW 1.54 1.58 1.63 1.69 1.67 1.71 1.78 Amps 7.2 7.3 7.5 7.8 7.7 7.8 8.1 HI PR 140 150 159 166 157 169 178 LO PR 59 63 69 74 63 67 73 MBh 22.7 23.4 25.3 27.2 22.2 22.8 24.7 S/T 0.82 0.74 0.56 0.36 0.85 0.76 0.58 ∆T 19 18 14 10 19 18 15 kW 1.55 1.59 1.65 1.71 1.69 1.73 1.79 900 Amps 7.3 7.4 7.6 7.8 7.7 7.9 8.1 HI PR 141 152 160 167 158 170 180 LO PR 60 64 70 74 63 68 74 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 70 IDB 65 23.8 0.34 11 1.79 8.1 180 75 25.8 0.35 10 1.84 8.3 186 78 26.5 0.37 10 1.86 8.4 188 79 71 19.4 0.80 20 1.74 8.0 173 63 21.0 0.83 20 1.79 8.2 178 65 21.7 0.87 19 1.81 8.3 180 66 59 19.1 0.71 18 1.73 8.0 171 63 20.7 0.73 17 1.78 8.2 176 65 21.3 0.77 17 1.79 8.2 178 65 71 - 59 17.7 0.76 18 1.91 8.9 219 69 19.2 0.79 17 1.97 9.1 226 71 19.7 0.82 17 1.99 9.2 228 72 63 18.3 0.63 15 1.96 9.1 236 73 19.9 0.66 15 2.02 9.3 243 76 20.5 0.69 14 2.04 9.4 246 76 67 20.1 0.44 12 2.03 9.4 249 80 21.8 0.45 11 2.09 9.6 257 83 22.4 0.48 11 2.11 9.7 259 84 105 71 - 59 16.4 0.76 16 1.99 9.4 242 71 17.8 0.79 16 2.05 9.6 250 74 18.3 0.83 16 2.07 9.7 252 74 63 17.0 0.64 14 2.04 9.6 261 76 18.4 0.66 14 2.10 9.8 269 78 19.0 0.69 13 2.12 9.9 271 79 67 18.6 0.44 11 2.11 9.8 275 83 20.2 0.46 11 2.17 10.1 284 86 20.8 0.48 10 2.19 10.2 287 86 115 71 - 21.6 23.2 18.9 19.5 21.1 22.7 18.0 18.5 20.1 21.5 16.7 17.2 18.6 19.9 0.54 0.35 0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.37 0.87 0.78 0.59 0.38 15 11 21 19 16 11 20 19 15 11 19 17 14 10 1.85 1.92 1.85 1.89 1.96 2.03 1.93 1.98 2.05 2.13 2.01 2.06 2.13 2.21 8.4 8.7 8.5 8.7 8.9 9.2 9.0 9.2 9.4 9.7 9.4 9.6 9.9 10.2 196 205 197 212 224 233 222 238 252 263 245 263 278 290 74 78 67 71 77 82 70 74 81 86 72 77 84 89 23.4 25.2 20.5 21.1 22.9 24.5 19.5 20.1 21.7 23.3 18.1 18.6 20.1 21.6 0.56 0.36 0.86 0.77 0.58 0.37 0.89 0.80 0.60 0.39 0.90 0.81 0.61 0.39 15 10 20 19 15 11 20 18 15 10 19 17 14 10 1.90 1.97 1.90 1.95 2.02 2.09 1.99 2.04 2.11 2.19 2.07 2.12 2.20 2.28 8.6 8.9 8.7 8.9 9.2 9.5 9.2 9.4 9.7 10.0 9.7 9.9 10.2 10.5 203 211 203 218 231 241 228 246 260 271 252 272 287 299 76 81 69 73 80 85 72 77 84 89 74 79 86 92 24.1 25.9 21.1 21.8 23.6 25.3 20.1 20.7 22.4 24.0 18.6 19.1 20.7 22.2 0.59 0.38 0.90 0.81 0.61 0.39 0.94 0.84 0.63 0.41 0.94 0.84 0.64 0.41 15 10 19 18 15 10 19 18 14 10 18 17 14 9 1.92 1.99 1.92 1.96 2.04 2.11 2.01 2.06 2.13 2.21 2.09 2.14 2.22 2.30 8.7 9.0 8.8 9.0 9.2 9.5 9.3 9.5 9.7 10.1 9.7 10.0 10.3 10.6 205 213 205 221 233 243 231 248 262 273 255 274 290 302 77 82 69 74 80 86 73 77 84 90 75 80 87 93 Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan) kW = Total system power Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions 20.0 0.72 19 1.79 8.2 186 67 21.7 0.75 19 1.84 8.4 192 69 22.3 0.78 18 1.85 8.5 194 70 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 19.8 21.7 18.6 19.3 21.1 0.59 0.41 0.73 0.61 0.42 15 12 18 15 12 1.77 1.83 1.83 1.87 1.94 8.1 8.4 8.4 8.6 8.9 184 194 195 210 221 67 73 66 70 77 21.4 23.5 20.2 20.9 22.9 0.61 0.42 0.76 0.63 0.44 15 11 18 15 12 1.82 1.89 1.88 1.93 2.00 8.3 8.6 8.6 8.8 9.1 190 200 201 216 228 69 75 68 72 79 22.1 24.2 20.8 21.5 23.6 0.64 0.44 0.79 0.66 0.46 14 11 17 15 11 1.84 1.90 1.90 1.95 2.02 8.4 8.6 8.7 8.9 9.2 192 202 203 218 231 69 76 69 73 80 Expanded Cooling Data — GSC130241F* www.goodmanmfg.com SS-GSC13 SS-GSC13 www.goodmanmfg.com 21.5 0.84 24 1.56 7.3 149 63 23.3 0.87 23 1.60 7.5 153 65 24.0 0.91 22 1.62 7.5 155 65 MBh 21.1 S/T 0.87 ∆T 24 kW 1.52 Amps 7.1 HI PR 138 LO PR 59 MBh 22.8 S/T 0.90 ∆T 24 kW 1.57 Amps 7.3 HI PR 142 LO PR 61 MBh 23.5 S/T 0.95 ∆T 23 kW 1.58 Amps 7.4 HI PR 144 LO PR 61 900 800 700 63 21.2 0.78 22 1.55 7.2 147 62 22.9 0.81 21 1.59 7.4 152 64 23.6 0.85 20 1.60 7.5 153 65 Airflow 59 MBh 20.7 S/T 0.83 ∆T 23 kW 1.51 700 Amps 7.1 HI PR 137 LO PR 58 MBh 22.5 S/T 0.86 ∆T 22 kW 1.55 800 Amps 7.3 HI PR 141 LO PR 60 MBh 23.1 S/T 0.90 ∆T 21 kW 1.57 900 Amps 7.3 HI PR 142 LO PR 61 22.5 0.76 22 1.62 7.5 157 68 24.4 0.79 22 1.66 7.7 162 70 25.1 0.82 21 1.68 7.7 164 71 24.0 0.61 19 1.68 7.7 164 73 26.0 0.64 19 1.72 7.9 169 75 26.8 0.67 18 1.74 8.0 171 76 67 71 22.6 24.2 0.63 0.5 19 15 1.60 1.7 7.4 7.7 155 162.2 68 72.1 24.5 26.2 0.66 0.5 18 15 1.65 1.7 7.6 7.8 160 167.2 70 74.3 25.2 27.0 0.69 0.5 18 14 1.66 1.7 7.7 7.9 162 168.9 70 75.1 20.6 0.90 24 1.66 7.6 155 62 22.3 0.93 24 1.70 7.8 160 64 23.0 0.98 23 1.72 7.9 161 65 59 20.2 0.86 23 1.64 7.6 154 62 21.9 0.89 22 1.69 7.7 158 63 22.6 0.93 22 1.70 7.8 160 64 21.0 0.87 24 1.70 7.8 167 66 22.7 0.90 24 1.75 8.0 172 68 23.4 0.95 23 1.76 8.0 174 69 63 20.7 0.81 22 1.68 7.7 165 66 22.4 0.84 22 1.73 7.9 170 68 23.1 0.88 21 1.75 8.0 172 68 75 22.0 0.78 23 1.76 8.0 176 72 23.8 0.81 22 1.81 8.2 182 74 24.5 0.85 21 1.83 8.2 183 75 67 22.1 0.66 19 1.74 7.9 174 72 23.9 0.68 19 1.79 8.1 180 74 24.7 0.71 18 1.81 8.2 182 74 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65 23.5 0.64 20 1.82 8.2 184 77 25.4 0.66 19 1.88 8.4 189 79 26.2 0.69 19 1.89 8.5 191 80 71 23.6 0.49 15 1.81 8.2 182 76 25.6 0.51 15 1.86 8.4 188 79 26.4 0.53 14 1.88 8.4 189 79 20.1 0.92 24 1.78 8.2 176 65 21.8 0.96 24 1.83 8.4 182 67 22.4 1.00 23 1.84 8.4 184 67 59 19.8 0.88 23 1.76 8.1 175 64 21.4 0.91 22 1.81 8.3 180 66 22.0 0.96 22 1.83 8.4 182 67 21.5 0.80 23 1.89 8.6 200 75 23.3 0.83 22 1.94 8.8 207 77 24.0 0.87 21 1.96 8.9 209 78 22.9 0.65 20 1.96 8.8 209 80 24.8 0.68 19 2.01 9.1 216 82 25.6 0.71 19 2.03 9.1 218 83 19.6 0.95 25 1.88 8.6 201 68 21.2 0.99 24 1.93 8.9 207 70 21.9 1.00 22 1.95 8.9 209 71 20.0 0.92 24 1.93 8.8 216 72 21.7 0.95 24 1.98 9.0 223 74 22.3 1.00 23 2.00 9.1 225 75 20.9 0.83 23 2.00 9.1 228 79 22.7 0.86 22 2.05 9.3 235 81 23.4 0.90 22 2.07 9.4 238 82 22.3 0.67 20 2.07 9.4 238 84 24.2 0.70 19 2.13 9.6 245 87 24.9 0.73 19 2.15 9.7 248 87 71 22.5 0.52 15 2.05 9.3 236 83 24.4 0.54 15 2.11 9.5 243 86 25.1 0.56 14 2.13 9.6 245 87 18.6 0.99 24 1.97 9.1 226 71 20.2 1.00 23 2.03 9.3 233 73 20.8 1.00 21 2.04 9.4 235 74 59 18.3 0.94 23 1.95 9.0 224 70 19.8 0.98 22 2.01 9.3 231 73 20.4 1.00 21 2.03 9.3 233 73 19.0 0.95 24 2.02 9.3 243 76 20.6 0.99 23 2.08 9.5 251 78 21.2 1.00 22 2.10 9.6 253 79 63 18.7 0.89 22 2.00 9.2 241 75 20.3 0.92 21 2.06 9.5 248 77 20.9 0.96 21 2.08 9.5 251 78 19.9 0.86 23 2.09 9.6 257 83 21.6 0.89 22 2.15 9.8 265 85 22.2 0.94 21 2.17 9.9 267 86 67 20.0 0.72 19 2.07 9.5 254 82 21.7 0.75 19 2.13 9.7 262 84 22.3 0.78 18 2.15 9.8 265 85 105 21.2 0.70 19 2.17 9.9 268 88 23.0 0.73 19 2.23 10.1 276 91 23.7 0.76 18 2.25 10.2 279 92 71 21.4 0.5 15 2.2 9.8 265.2 87.2 23.2 0.6 15 2.2 10.1 273.4 89.8 23.8 0.6 14 2.2 10.1 276.1 90.7 17.3 1.00 23 2.05 9.6 250 74 18.7 1.00 21 2.10 9.8 257 76 19.3 1.00 20 2.12 9.9 260 77 59 17.0 0.95 21 2.03 9.5 247 73 18.4 0.99 21 2.09 9.7 255 75 18.9 1.00 19 2.10 9.8 257 76 17.6 0.96 22 2.10 9.8 269 78 19.1 1.00 22 2.16 10.0 277 81 19.6 1.00 20 2.18 10.1 280 82 63 17.3 0.89 20 2.08 9.7 266 78 18.8 0.93 20 2.14 10.0 274 80 19.3 0.97 19 2.16 10.0 277 81 18.4 0.87 21 2.17 10.1 284 85 20.0 0.90 21 2.24 10.3 293 88 20.6 0.94 20 2.26 10.4 295 89 67 18.5 0.73 18 2.15 10.0 281 85 20.1 0.75 17 2.22 10.3 290 87 20.7 0.79 17 2.24 10.3 293 88 115 19.7 0.71 18 2.26 10.4 296 91 21.3 0.73 18 2.32 10.7 305 94 21.9 0.77 17 2.34 10.8 308 95 71 19.8 0.54 14 2.23 10.3 293 90 21.4 0.56 14 2.30 10.6 302 93 22.1 0.59 13 2.32 10.7 305 94 Shaded area reflects AHRI conditions Amps = outdoor unit amps (comp.+fan) kW = Total system power Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions 20.5 0.89 24 1.82 8.3 190 69 22.2 0.92 24 1.87 8.5 196 71 22.9 0.97 23 1.89 8.6 198 72 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 20.2 21.6 23.1 19.3 19.7 21.0 0.83 0.67 0.5 0.91 0.85 0.69 22 19 15 23 22 19 1.80 1.87 1.9 1.86 1.91 1.98 8.3 8.5 8.8 8.6 8.8 9.0 188 198 207.0 199 214 226 68 74 79.2 67 72 78 21.9 23.4 25.0 20.9 21.3 22.8 0.86 0.70 0.5 0.94 0.88 0.72 22 19 15 23 22 19 1.85 1.92 2.0 1.92 1.96 2.04 8.5 8.7 9.0 8.8 9.0 9.2 194 205 213.4 205 221 233 70 77 81.6 69 74 81 22.5 24.1 25.7 21.5 22.0 23.5 0.90 0.73 0.5 1.00 0.93 0.75 21 18 14 22 21 18 1.87 1.94 2.0 1.93 1.98 2.05 8.5 8.8 9.1 8.9 9.0 9.3 196 207 215.5 207 223 235 71 77 82.4 70 74 81 Expanded Cooling Data — GSC130241F* (cont.) 7 8 Airflow MBh S/T ∆T kW 831 Amps HI PR LO PR MBh S/T ∆T kW 950 Amps HI PR LO PR MBh S/T ∆T 1069 kW Amps HI PR LO PR 59 25.1 0.67 19 1.90 7.0 147 58 27.2 0.69 18 1.94 7.2 152 60 28.0 0.73 18 1.96 7.2 153 60 63 26.0 0.56 16 1.94 7.1 158 61 28.2 0.58 16 1.98 7.3 163 63 29.0 0.61 15 2.00 7.4 165 64 67 28.5 0.39 12 1.99 7.4 167 67 30.9 0.40 12 2.04 7.6 172 69 31.8 0.42 12 2.06 7.6 174 70 71 - 59 24.5 0.69 19 2.04 7.5 165 61 26.6 0.72 18 2.08 7.7 170 63 27.4 0.75 18 2.10 7.8 172 64 63 25.4 0.58 16 2.08 7.7 178 65 27.5 0.60 16 2.13 7.9 183 67 28.4 0.63 15 2.14 7.9 185 68 75 67 27.9 0.40 12 2.14 7.9 188 71 30.2 0.42 12 2.19 8.1 193 73 31.1 0.44 12 2.21 8.2 195 74 MBh 25.5 26.3 28.5 30.5 24.9 25.7 27.8 S/T 0.76 0.68 0.51 0.33 0.79 0.70 0.53 ∆T 21 20 16 11 22 20 16 kW 1.91 1.95 2.01 2.07 2.05 2.09 2.16 831 Amps 7.1 7.2 7.4 7.7 7.6 7.7 8.0 HI PR 149 160 169 176 167 179 189 LO PR 58 62 68 72 62 66 72 MBh 27.7 28.5 30.8 33.1 27.0 27.8 30.1 S/T 0.79 0.70 0.53 0.34 0.82 0.73 0.55 ∆T 21 19 16 11 21 20 16 950 75 kW 1.96 2.00 2.06 2.12 2.10 2.14 2.21 Amps 7.2 7.4 7.6 7.9 7.8 7.9 8.2 HI PR 153 165 174 182 172 185 195 LO PR 60 64 70 74 64 68 74 MBh 28.5 29.3 31.8 34.1 27.8 28.7 31.0 S/T 0.83 0.74 0.56 0.36 0.86 0.77 0.58 ∆T 20 19 15 11 20 19 15 1.97 2.01 2.07 2.14 2.12 2.16 2.23 1069 kW Amps 7.3 7.5 7.7 7.9 7.8 8.0 8.3 HI PR 155 166 176 183 174 187 197 LO PR 61 65 71 75 64 68 75 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 70 IDB 65 29.8 0.34 11 2.23 8.3 198 76 32.3 0.36 11 2.28 8.5 204 79 33.3 0.37 11 2.30 8.5 206 79 71 24.4 0.81 22 2.17 8.2 190 64 26.4 0.84 21 2.23 8.4 195 66 27.2 0.88 21 2.24 8.5 197 67 59 23.9 0.71 19 2.16 8.1 188 63 25.9 0.74 18 2.21 8.3 193 65 26.7 0.77 18 2.23 8.4 195 66 71 - 59 22.2 0.76 19 2.36 9.1 240 70 24.0 0.79 18 2.41 9.4 248 72 24.8 0.83 18 2.43 9.5 250 73 63 23.0 0.64 16 2.41 9.3 259 74 24.9 0.66 16 2.47 9.6 267 77 25.7 0.69 15 2.49 9.7 269 77 67 25.2 0.44 12 2.48 9.6 273 81 27.3 0.46 12 2.55 9.9 282 84 28.1 0.48 12 2.57 10.0 285 84 105 71 - 59 20.6 0.77 17 2.44 9.6 266 72 22.3 0.80 17 2.50 9.9 274 74 22.9 0.83 16 2.52 10.0 277 75 63 21.3 0.64 15 2.49 9.9 286 77 23.1 0.66 15 2.55 10.1 295 79 23.8 0.70 14 2.57 10.2 298 80 67 23.3 0.44 11 2.57 10.2 302 84 25.3 0.46 11 2.63 10.5 311 86 26.1 0.48 11 2.65 10.5 314 87 115 71 - 25.1 0.72 20 2.22 8.4 204 68 27.2 0.75 20 2.27 8.6 210 70 28.0 0.78 19 2.29 8.7 212 71 27.1 29.1 23.8 24.5 26.5 28.4 22.6 23.2 25.2 27.0 20.9 21.5 23.3 25.0 0.55 0.35 0.83 0.74 0.56 0.36 0.86 0.77 0.59 0.38 0.87 0.78 0.59 0.38 16 11 22 20 17 11 22 20 16 11 20 19 15 10 2.29 2.36 2.28 2.33 2.41 2.48 2.38 2.43 2.50 2.58 2.46 2.51 2.59 2.67 8.6 8.9 8.7 8.9 9.2 9.5 9.2 9.4 9.7 10.1 9.7 10.0 10.3 10.6 215 225 216 232 245 256 243 261 276 288 268 289 305 318 74 79 67 72 78 83 71 75 82 87 73 78 85 90 29.4 31.6 25.7 26.5 28.7 30.8 24.5 25.2 27.3 29.2 22.7 23.3 25.2 27.1 0.57 0.36 0.86 0.77 0.58 0.38 0.90 0.80 0.61 0.39 0.90 0.81 0.61 0.39 16 11 22 20 16 11 21 20 16 11 20 18 15 10 2.35 2.42 2.34 2.39 2.46 2.54 2.43 2.49 2.57 2.65 2.52 2.57 2.65 2.74 8.8 9.2 8.9 9.1 9.4 9.8 9.5 9.7 10.0 10.3 10.0 10.2 10.6 10.9 222 232 223 240 253 264 250 269 285 297 277 298 314 328 77 82 69 74 81 86 73 77 84 90 75 80 87 93 30.3 32.5 26.5 27.3 29.5 31.7 25.2 25.9 28.1 30.1 23.3 24.0 26.0 27.9 0.59 0.38 0.91 0.81 0.61 0.39 0.94 0.84 0.64 0.41 0.95 0.85 0.64 0.41 15 11 21 19 16 11 20 19 15 11 19 18 14 10 2.36 2.44 2.36 2.41 2.48 2.57 2.45 2.51 2.59 2.67 2.54 2.59 2.68 2.76 8.9 9.2 9.0 9.2 9.5 9.8 9.5 9.8 10.1 10.4 10.1 10.3 10.6 11.0 224 234 225 242 255 266 253 272 287 300 279 301 318 331 77 83 70 75 81 87 73 78 85 91 76 81 88 94 Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan) kW = Total system power Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 24.8 27.2 23.4 24.2 26.5 0.59 0.41 0.73 0.61 0.42 16 12 19 16 12 2.20 2.27 2.27 2.31 2.39 8.3 8.5 8.6 8.8 9.1 202 213 214 230 243 67 74 67 71 77 26.9 29.5 25.3 26.2 28.7 0.61 0.43 0.76 0.63 0.44 16 12 19 16 12 2.26 2.33 2.32 2.37 2.44 8.5 8.8 8.9 9.1 9.3 208 220 220 237 250 70 76 69 73 80 27.7 30.3 26.1 27.0 29.6 0.64 0.45 0.80 0.67 0.46 15 12 18 15 12 2.27 2.34 2.34 2.39 2.46 8.6 8.8 8.9 9.1 9.4 210 222 223 239 253 70 77 69 74 81 Expanded Cooling Data — GSC130301** www.goodmanmfg.com SS-GSC13 SS-GSC13 www.goodmanmfg.com 63 26.6 0.78 23 1.97 7.3 161 63 28.8 0.81 23 2.01 7.5 166 65 29.6 0.85 22 2.03 7.5 168 65 27.0 0.84 25 1.98 7.3 163 63 29.2 0.87 25 2.03 7.5 168 65 30.1 0.92 24 2.04 7.6 170 66 Airflow 59 MBh 26.0 S/T 0.83 ∆T 24 kW 1.93 831 Amps 7.1 HI PR 150 LO PR 59 MBh 28.2 S/T 0.86 ∆T 24 kW 1.97 950 Amps 7.3 HI PR 155 LO PR 61 MBh 29.0 S/T 0.91 ∆T 23 1.99 1069 kW Amps 7.4 HI PR 156 LO PR 61 MBh 26.4 S/T 0.87 ∆T 26 kW 1.94 831 Amps 7.2 HI PR 152 LO PR 60 MBh 28.7 S/T 0.91 ∆T 25 kW 1.99 950 Amps 7.4 HI PR 156 LO PR 61 MBh 29.5 S/T 0.95 ∆T 24 2.00 1069 kW Amps 7.4 HI PR 158 LO PR 62 28.2 0.76 24 2.04 7.5 172 69 30.6 0.79 23 2.09 7.7 178 71 31.5 0.83 22 2.10 7.8 179 72 30.1 0.62 21 2.10 7.8 180 74 32.6 0.64 20 2.15 8.0 185 76 33.6 0.67 19 2.17 8.1 187 77 67 71 28.4 30.3 0.64 0.5 20 16 2.02 2.1 7.5 7.7 171 177.8 68 72.9 30.7 32.9 0.66 0.5 20 16 2.07 2.1 7.7 7.9 176 183.3 71 75.2 31.7 33.9 0.69 0.5 19 15 2.09 2.2 7.7 8.0 178 185.2 71 75.9 25.8 0.90 26 2.08 7.7 170 63 28.0 0.94 25 2.13 7.9 175 65 28.8 0.98 24 2.15 8.0 177 65 59 25.4 0.86 24 2.07 7.6 168 62 27.5 0.89 24 2.12 7.8 174 64 28.3 0.94 23 2.13 7.9 175 65 26.3 0.87 25 2.13 7.9 183 67 28.5 0.91 25 2.18 8.1 189 69 29.4 0.95 24 2.19 8.1 191 70 63 25.9 0.81 23 2.11 7.8 181 66 28.1 0.84 23 2.16 8.0 187 68 29.0 0.88 22 2.18 8.1 189 69 75 27.6 0.79 24 2.19 8.1 193 73 29.9 0.82 24 2.24 8.3 199 75 30.8 0.86 23 2.26 8.4 201 76 67 27.7 0.66 20 2.17 8.0 191 72 30.0 0.68 20 2.23 8.3 197 75 30.9 0.72 19 2.24 8.3 199 75 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65 29.4 0.64 21 2.26 8.4 202 78 31.9 0.66 20 2.32 8.6 208 80 32.8 0.69 20 2.33 8.7 210 81 71 29.6 0.49 16 2.24 8.3 200 77 32.1 0.51 16 2.30 8.5 206 79 33.1 0.54 15 2.32 8.6 208 80 25.2 0.93 26 2.21 8.3 193 65 27.3 0.96 25 2.26 8.5 199 67 28.1 1.00 24 2.28 8.6 201 68 59 24.8 0.88 24 2.19 8.2 191 65 26.9 0.92 24 2.25 8.5 197 67 27.7 0.96 23 2.26 8.5 199 67 26.9 0.81 24 2.33 8.8 220 76 29.2 0.84 24 2.38 9.0 227 78 30.0 0.88 23 2.40 9.1 229 79 28.7 0.66 21 2.40 9.1 229 81 31.1 0.68 20 2.46 9.3 236 83 32.1 0.71 20 2.48 9.4 239 84 24.6 0.96 26 2.32 8.8 220 69 26.7 0.99 26 2.38 9.1 227 71 27.5 1.00 24 2.40 9.2 229 71 25.1 0.92 26 2.37 9.1 237 73 27.2 0.96 25 2.43 9.3 244 75 28.0 1.00 24 2.45 9.4 247 76 26.3 0.83 24 2.44 9.3 250 80 28.5 0.86 24 2.51 9.6 258 82 29.3 0.91 23 2.53 9.7 261 83 28.0 0.68 21 2.52 9.7 261 85 30.4 0.70 21 2.59 9.9 269 88 31.3 0.74 20 2.61 10.0 272 88 71 28.2 0.52 16 2.50 9.6 258 84 30.6 0.54 16 2.57 9.8 266 87 31.5 0.57 15 2.59 9.9 269 88 23.4 0.99 26 2.41 9.4 248 72 25.3 1.00 25 2.47 9.6 255 74 26.1 1.00 22 2.49 9.7 258 75 59 23.0 0.95 24 2.39 9.3 245 71 24.9 0.98 24 2.45 9.5 253 73 25.6 1.00 22 2.47 9.6 255 74 23.8 0.96 25 2.47 9.6 267 77 25.8 0.99 25 2.53 9.9 275 79 26.6 1.00 23 2.55 9.9 278 80 63 23.5 0.89 23 2.45 9.5 264 76 25.4 0.92 23 2.51 9.8 272 78 26.2 0.97 22 2.53 9.9 275 79 25.0 0.87 24 2.54 9.9 282 84 27.0 0.90 23 2.61 10.2 290 86 27.8 0.94 23 2.63 10.3 293 87 67 25.1 0.72 20 2.52 9.8 279 83 27.2 0.75 20 2.59 10.1 287 85 28.0 0.79 19 2.61 10.2 290 86 105 26.6 0.70 21 2.63 10.3 294 89 28.8 0.73 20 2.69 10.5 303 92 29.7 0.76 20 2.72 10.6 306 93 71 26.8 0.5 16 2.6 10.2 290.8 88.1 29.0 0.6 16 2.7 10.4 299.8 90.9 29.9 0.6 15 2.7 10.5 302.8 91.8 21.7 1.00 24 2.50 9.9 274 74 23.5 1.00 23 2.56 10.2 282 77 24.2 1.00 21 2.58 10.3 285 77 59 21.3 0.96 22 2.48 9.8 271 74 23.1 0.99 22 2.54 10.1 279 76 23.7 1.00 20 2.56 10.2 282 77 22.1 0.97 24 2.55 10.1 295 79 23.9 1.00 23 2.61 10.4 304 82 24.6 1.00 21 2.64 10.5 307 82 63 21.7 0.90 22 2.53 10.0 292 78 23.6 0.93 21 2.59 10.3 301 81 24.3 1.00 21 2.61 10.4 304 82 23.1 0.87 22 2.63 10.5 311 86 25.0 0.90 22 2.70 10.7 321 89 25.8 0.95 21 2.72 10.8 324 90 67 23.2 0.73 19 2.61 10.4 308 86 25.2 0.76 18 2.68 10.6 318 88 25.9 0.79 18 2.70 10.7 321 89 115 24.7 0.71 19 2.72 10.8 325 92 26.7 0.73 19 2.79 11.1 335 95 27.5 0.77 18 2.81 11.2 338 96 71 24.8 0.55 15 2.70 10.7 321 91 26.9 0.57 15 2.76 11.0 331 94 27.7 0.59 14 2.79 11.1 335 95 Shaded area reflects AHRI conditions Amps = outdoor unit amps (comp.+fan) kW = Total system power Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions 25.7 0.90 25 2.26 8.5 208 70 27.9 0.93 25 2.31 8.7 215 72 28.7 0.97 24 2.33 8.8 217 72 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 25.3 27.1 28.9 24.2 24.7 26.4 0.83 0.68 0.5 0.91 0.86 0.70 23 20 16 24 23 20 2.24 2.31 2.4 2.30 2.35 2.42 8.4 8.7 9.0 8.8 9.0 9.3 206 218 227.0 218 235 248 69 75 80.1 68 72 79 27.4 29.3 31.3 26.2 26.8 28.6 0.86 0.70 0.5 0.95 0.89 0.72 23 20 16 24 23 20 2.29 2.36 2.4 2.36 2.41 2.49 8.7 8.9 9.2 9.0 9.2 9.5 212 224 234.0 225 242 256 71 77 82.5 70 75 81 28.3 30.2 32.3 27.0 27.6 29.5 0.90 0.73 0.5 1.00 0.93 0.76 22 19 15 23 22 19 2.31 2.38 2.5 2.38 2.43 2.51 8.7 9.0 9.3 9.1 9.3 9.6 215 227 236.3 227 244 258 72 78 83.4 71 75 82 Expanded Cooling Data — GSC130301** (cont.) 9 10 Airflow MBh S/T ∆T kW 963 Amps HI PR LO PR MBh S/T ∆T 1100 kW Amps HI PR LO PR MBh S/T ∆T 1238 kW Amps HI PR LO PR 59 30.0 0.67 19 2.31 8.8 141 59 32.5 0.70 19 2.37 9.0 146 60 33.5 0.73 18 2.39 9.1 147 61 63 31.1 0.56 17 2.36 9.0 152 62 33.7 0.58 16 2.42 9.2 157 64 34.7 0.61 16 2.43 9.3 158 65 67 34.1 0.39 13 2.43 9.3 160 68 36.9 0.40 12 2.49 9.5 165 70 38.1 0.42 12 2.51 9.6 167 71 71 - 59 29.3 0.70 19 2.48 9.5 158 62 31.8 0.72 19 2.54 9.7 163 64 32.7 0.76 18 2.56 9.8 165 65 63 30.4 0.58 17 2.53 9.7 170 66 32.9 0.60 17 2.59 10.0 176 68 33.9 0.63 16 2.61 10.1 178 69 75 67 33.3 0.40 13 2.61 10.0 180 72 36.1 0.42 13 2.67 10.3 186 74 37.2 0.44 12 2.69 10.4 187 75 MBh 30.5 31.4 34.0 36.5 29.8 30.7 33.2 S/T 0.76 0.68 0.52 0.33 0.79 0.71 0.54 ∆T 22 21 17 12 23 21 17 kW 2.33 2.38 2.45 2.52 2.50 2.55 2.63 963 Amps 8.9 9.1 9.4 9.7 9.6 9.8 10.1 HI PR 143 153 162 169 160 172 182 LO PR 59 63 69 73 63 67 73 MBh 33.1 34.1 36.9 39.6 32.3 33.3 36.0 S/T 0.79 0.71 0.54 0.34 0.82 0.73 0.56 ∆T 22 20 17 11 22 20 17 1100 kW 75 2.39 2.43 2.51 2.58 2.56 2.61 2.69 Amps 9.1 9.3 9.6 10.0 9.8 10.1 10.4 HI PR 147 158 167 174 165 178 187 LO PR 61 65 71 76 65 69 75 MBh 34.1 35.1 38.0 40.8 33.3 34.3 37.1 S/T 0.83 0.74 0.56 0.36 0.86 0.77 0.58 ∆T 21 19 16 11 21 20 16 2.40 2.45 2.53 2.60 2.58 2.63 2.72 1238 kW Amps 9.2 9.4 9.7 10.0 9.9 10.1 10.5 HI PR 148 160 169 176 167 179 189 LO PR 62 66 72 76 65 69 76 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 70 IDB 65 35.7 0.34 12 2.71 10.5 190 77 38.7 0.36 12 2.78 10.7 196 80 39.8 0.37 11 2.80 10.8 197 81 71 29.1 0.81 23 2.65 10.4 182 65 31.5 0.84 22 2.72 10.6 188 67 32.5 0.88 21 2.74 10.7 190 68 59 28.6 0.71 20 2.63 10.3 180 64 31.0 0.74 19 2.69 10.5 186 66 32.0 0.78 18 2.71 10.6 188 67 71 - 59 26.5 0.76 19 2.87 11.6 231 71 28.8 0.79 19 2.94 11.9 238 73 29.6 0.83 18 2.97 12.1 240 74 63 27.5 0.64 17 2.93 11.9 248 75 29.8 0.66 16 3.01 12.2 256 78 30.7 0.69 16 3.03 12.3 259 79 67 30.1 0.44 13 3.03 12.3 262 82 32.7 0.46 13 3.10 12.6 270 85 33.6 0.48 12 3.13 12.7 273 86 105 71 - 59 24.6 0.77 18 2.97 12.3 255 73 26.6 0.80 18 3.04 12.6 263 76 27.4 0.84 17 3.07 12.7 266 76 63 25.5 0.64 16 3.03 12.6 274 78 27.6 0.67 15 3.11 12.9 283 80 28.4 0.70 15 3.13 13.1 286 81 67 27.9 0.45 12 3.13 13.0 290 85 30.2 0.46 12 3.21 13.4 299 88 31.2 0.49 11 3.23 13.5 302 89 115 71 - 30.0 0.73 21 2.71 10.6 196 69 32.5 0.75 20 2.77 10.9 202 71 33.5 0.79 20 2.79 11.0 204 72 32.5 34.8 28.4 29.3 31.7 34.0 27.0 27.8 30.1 32.3 25.0 25.7 27.9 29.9 0.55 0.35 0.84 0.75 0.57 0.36 0.87 0.78 0.59 0.38 0.88 0.78 0.59 0.38 17 12 23 21 17 12 22 21 17 12 21 19 16 11 2.79 2.88 2.78 2.84 2.93 3.03 2.90 2.96 3.05 3.15 2.99 3.06 3.16 3.26 10.9 11.3 11.0 11.3 11.7 12.1 11.7 12.0 12.4 12.9 12.4 12.7 13.1 13.6 207 216 207 223 236 246 233 251 265 276 258 277 293 305 76 81 68 73 79 85 72 76 83 89 74 79 86 92 35.2 37.7 30.8 31.7 34.3 36.8 29.2 30.1 32.6 35.0 27.1 27.9 30.2 32.4 0.57 0.37 0.87 0.78 0.59 0.38 0.90 0.81 0.61 0.39 0.91 0.81 0.62 0.40 17 12 22 21 17 12 22 20 17 11 21 19 16 11 2.86 2.95 2.85 2.91 3.00 3.10 2.97 3.03 3.13 3.23 3.07 3.13 3.24 3.34 11.2 11.6 11.3 11.6 12.0 12.4 12.1 12.3 12.7 13.2 12.7 13.1 13.5 14.0 213 222 214 230 243 253 240 259 273 285 266 286 302 315 78 83 70 75 82 87 74 79 86 91 76 81 89 95 36.2 38.9 31.7 32.6 35.3 37.9 30.1 31.0 33.6 36.0 27.9 28.7 31.1 33.4 0.60 0.38 0.91 0.81 0.62 0.40 0.95 0.85 0.64 0.41 0.95 0.85 0.65 0.42 16 11 21 20 16 11 21 19 16 11 20 18 15 10 2.88 2.97 2.87 2.94 3.03 3.13 2.99 3.06 3.15 3.26 3.09 3.16 3.26 3.37 11.3 11.8 11.4 11.7 12.1 12.5 12.2 12.5 12.9 13.3 12.9 13.2 13.6 14.1 215 225 216 232 245 256 243 261 276 288 268 289 305 318 79 84 71 76 83 88 75 79 87 92 77 82 90 95 Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan) kW = Total system power Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 29.7 32.5 27.9 29.0 31.7 0.60 0.41 0.74 0.62 0.43 17 13 20 17 13 2.68 2.77 2.76 2.82 2.91 10.5 10.8 10.9 11.2 11.6 194 205 205 221 233 69 75 68 72 79 32.2 35.2 30.3 31.4 34.4 0.62 0.43 0.76 0.64 0.44 17 13 19 17 13 2.75 2.84 2.83 2.89 2.98 10.8 11.1 11.2 11.5 11.9 200 211 212 228 240 71 77 70 74 81 33.1 36.3 31.2 32.3 35.4 0.65 0.45 0.80 0.67 0.46 16 12 19 16 12 2.77 2.86 2.85 2.91 3.00 10.9 11.2 11.3 11.6 12.0 202 213 214 230 243 71 78 70 75 82 Expanded Cooling Data — GSC130361G* www.goodmanmfg.com SS-GSC13 SS-GSC13 www.goodmanmfg.com 63 31.8 0.79 24 2.40 9.2 155 64 34.4 0.81 23 2.45 9.4 160 66 35.4 0.85 22 2.47 9.5 161 66 32.2 0.85 26 2.41 9.2 157 64 34.9 0.88 26 2.47 9.5 161 66 36.0 0.92 25 2.49 9.6 163 67 Airflow 59 MBh 31.1 S/T 0.84 ∆T 25 kW 2.35 963 Amps 9.0 HI PR 144 LO PR 60 MBh 33.7 S/T 0.87 ∆T 24 2.40 1100 kW Amps 9.2 HI PR 149 LO PR 62 MBh 34.7 S/T 0.91 ∆T 23 2.42 1238 kW Amps 9.3 HI PR 150 LO PR 62 MBh 31.6 S/T 0.88 ∆T 27 kW 2.37 963 Amps 9.0 HI PR 145 LO PR 60 MBh 34.3 S/T 0.91 ∆T 26 2.42 1100 kW Amps 9.3 HI PR 150 LO PR 62 MBh 35.3 S/T 0.95 ∆T 25 2.44 1238 kW Amps 9.4 HI PR 151 LO PR 63 33.8 0.76 25 2.49 9.5 165 70 36.6 0.79 24 2.55 9.8 170 72 37.7 0.83 23 2.57 9.9 172 73 36.0 0.62 21 2.56 9.9 172 75 39.0 0.64 21 2.62 10.1 178 77 40.2 0.67 20 2.65 10.2 180 78 67 71 33.9 36.3 0.64 0.5 21 17 2.47 2.5 9.5 9.8 164 170.7 70 74.1 36.8 39.3 0.66 0.5 20 16 2.53 2.6 9.7 10.1 169 176.0 72 76.4 37.9 40.5 0.69 0.5 20 16 2.55 2.6 9.8 10.1 170 177.8 72 77.1 30.9 0.91 27 2.54 9.7 163 64 33.5 0.94 26 2.60 10.0 168 66 34.5 0.99 25 2.62 10.1 170 67 59 30.4 0.87 25 2.52 9.7 162 63 32.9 0.90 25 2.58 9.9 167 65 33.9 0.94 24 2.60 10.0 168 66 31.5 0.88 26 2.59 10.0 176 68 34.1 0.91 26 2.65 10.2 181 70 35.1 0.95 25 2.68 10.3 183 71 63 31.0 0.81 24 2.57 9.9 174 67 33.6 0.84 24 2.63 10.1 179 69 34.6 0.88 23 2.65 10.2 181 70 75 33.0 0.79 25 2.67 10.3 186 74 35.7 0.82 25 2.74 10.6 191 77 36.8 0.86 24 2.76 10.6 193 77 67 33.1 0.66 21 2.65 10.2 184 73 35.9 0.69 21 2.72 10.5 189 76 37.0 0.72 20 2.74 10.6 191 77 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65 35.2 0.64 22 2.76 10.6 194 79 38.1 0.67 21 2.82 10.9 199 81 39.3 0.70 20 2.85 11.0 201 82 71 35.4 0.50 17 2.73 10.6 192 78 38.4 0.51 16 2.80 10.8 198 81 39.5 0.54 16 2.82 10.9 199 81 30.2 0.93 27 2.69 10.5 186 66 32.7 0.97 26 2.76 10.8 191 68 33.7 1.00 25 2.78 10.9 193 69 59 29.6 0.89 25 2.67 10.5 184 66 32.1 0.92 25 2.74 10.7 190 68 33.1 0.97 24 2.76 10.8 191 68 32.2 0.81 25 2.84 11.1 211 77 34.9 0.84 25 2.90 11.4 218 80 35.9 0.88 24 2.93 11.5 220 80 34.3 0.66 22 2.93 11.5 220 82 37.2 0.68 21 3.00 11.9 227 85 38.3 0.72 20 3.02 12.0 229 86 29.4 0.96 27 2.83 11.2 211 70 31.9 1.00 27 2.90 11.6 218 72 32.8 1.00 24 2.92 11.7 220 73 30.0 0.93 27 2.89 11.5 228 74 32.5 0.96 26 2.96 11.8 235 77 33.5 1.00 25 2.98 11.9 237 77 31.4 0.84 25 2.98 11.9 240 81 34.0 0.87 25 3.05 12.2 248 84 35.0 0.91 24 3.08 12.3 250 84 33.5 0.68 22 3.08 12.3 251 86 36.3 0.71 21 3.15 12.7 258 89 37.4 0.74 21 3.18 12.8 261 90 71 33.7 0.52 17 3.05 12.2 248 85 36.6 0.54 17 3.13 12.5 256 88 37.7 0.57 16 3.15 12.7 258 89 27.9 1.00 27 2.94 11.9 238 73 30.3 1.00 25 3.02 12.3 245 75 31.2 1.00 23 3.04 12.4 248 76 59 27.5 0.95 25 2.92 11.8 236 72 29.8 0.99 25 2.99 12.2 243 75 30.7 1.00 23 3.02 12.3 245 75 28.5 0.96 26 3.01 12.2 256 78 30.9 1.00 26 3.08 12.6 264 80 31.8 1.00 24 3.11 12.7 267 81 63 28.1 0.89 24 2.98 12.1 253 77 30.4 0.93 24 3.06 12.5 261 79 31.3 1.00 23 3.08 12.6 264 80 29.8 0.87 25 3.10 12.6 270 85 32.3 0.90 24 3.18 13.0 279 88 33.3 0.95 23 3.21 13.1 282 88 67 30.0 0.73 21 3.08 12.5 268 84 32.5 0.75 20 3.15 12.9 276 87 33.5 0.79 20 3.18 13.0 279 88 105 31.8 0.71 21 3.20 13.1 282 90 34.5 0.73 21 3.28 13.5 291 93 35.5 0.77 20 3.31 13.6 294 94 71 32.1 0.5 17 3.2 13.0 279.2 89.5 34.7 0.6 16 3.3 13.3 287.8 92.3 35.8 0.6 16 3.3 13.5 290.7 93.2 25.9 1.00 25 3.04 12.6 263 76 28.0 1.00 23 3.12 13.0 271 78 28.9 1.00 21 3.14 13.1 274 79 59 25.4 0.96 23 3.02 12.5 260 75 27.6 1.00 23 3.09 12.9 268 77 28.4 1.00 21 3.12 13.0 271 78 26.4 0.97 25 3.11 12.9 283 80 28.6 1.00 24 3.19 13.3 292 83 29.5 1.00 22 3.21 13.4 295 84 63 26.0 0.90 22 3.08 12.8 280 80 28.2 0.93 22 3.16 13.2 289 82 29.0 1.00 22 3.19 13.3 292 83 27.6 0.88 23 3.21 13.4 299 88 29.9 0.91 23 3.29 13.7 308 91 30.8 0.95 22 3.32 13.9 311 91 67 27.8 0.73 19 3.18 13.2 296 87 30.1 0.76 19 3.26 13.6 305 90 31.0 0.80 18 3.29 13.7 308 91 115 29.5 0.71 20 3.31 13.9 312 94 31.9 0.74 20 3.40 14.2 321 96 32.9 0.77 19 3.43 14.4 324 97 71 29.7 0.55 16 3.29 13.7 308 93 32.2 0.57 15 3.37 14.1 318 95 33.1 0.60 15 3.40 14.2 321 96 Shaded area reflects AHRI conditions Amps = outdoor unit amps (comp.+fan) kW = Total system power Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions 30.7 0.90 26 2.75 10.8 200 71 33.3 0.93 26 2.82 11.1 206 73 34.3 0.98 25 2.84 11.2 208 74 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 30.3 32.4 34.6 28.9 29.5 31.6 0.83 0.68 0.5 0.92 0.86 0.70 24 21 17 25 24 21 2.73 2.81 2.9 2.81 2.87 2.96 10.7 11.0 11.4 11.1 11.4 11.8 198 209 217.9 209 225 238 70 76 81.3 69 73 80 32.8 35.1 37.5 31.3 32.0 34.2 0.87 0.70 0.5 0.95 0.89 0.73 24 21 16 25 24 21 2.79 2.88 3.0 2.87 2.94 3.03 11.0 11.3 11.8 11.4 11.7 12.1 204 215 224.6 216 232 245 72 79 83.8 71 76 83 33.8 36.1 38.6 32.3 33.0 35.2 0.91 0.74 0.6 1.00 0.94 0.76 23 20 16 24 23 20 2.82 2.90 3.0 2.90 2.96 3.05 11.1 11.4 11.9 11.6 11.8 12.2 206 218 226.9 218 235 248 73 80 84.7 72 77 84 Expanded Cooling Data — GSC130361G* (cont.) 11 12 Airflow MBh S/T ∆T 1225 kW Amps HI PR LO PR MBh S/T ∆T 1400 kW Amps HI PR LO PR MBh S/T ∆T 1575 kW Amps HI PR LO PR 59 35.6 0.69 18 2.12 8.1 126 60 38.6 0.72 18 2.18 8.3 130 62 39.7 0.75 17 2.20 8.3 131 62 63 36.9 0.58 16 2.17 8.2 136 64 40.0 0.60 16 2.23 8.4 140 66 41.2 0.63 15 2.26 8.5 141 66 67 40.4 0.40 12 2.25 8.5 143 69 43.8 0.41 12 2.32 8.7 148 72 45.1 0.43 11 2.34 8.8 149 72 71 - 59 34.8 0.72 19 2.31 8.6 141 63 37.7 0.74 18 2.38 8.9 146 65 38.8 0.78 18 2.40 8.9 147 66 63 36.0 0.60 16 2.37 8.8 152 67 39.0 0.62 16 2.44 9.1 157 69 40.2 0.65 15 2.46 9.1 159 70 75 67 39.5 0.41 12 2.46 9.1 161 73 42.8 0.43 12 2.53 9.3 166 76 44.0 0.45 12 2.55 9.4 167 76 MBh 36.2 37.3 40.3 43.3 35.3 36.4 39.4 S/T 0.78 0.70 0.53 0.34 0.81 0.73 0.55 ∆T 21 20 16 11 22 20 16 2.14 2.19 2.27 2.36 2.33 2.39 2.48 1225 kW Amps 8.1 8.3 8.5 8.8 8.7 8.9 9.2 HI PR 127 137 145 151 143 154 162 LO PR 60 64 70 75 64 68 74 MBh 39.2 40.4 43.7 46.9 38.3 39.4 42.7 S/T 0.81 0.73 0.55 0.35 0.84 0.75 0.57 ∆T 21 19 16 11 21 20 16 1400 kW 75 2.20 2.26 2.34 2.43 2.40 2.46 2.55 Amps 8.3 8.5 8.8 9.1 8.9 9.1 9.4 HI PR 131 141 149 156 147 159 167 LO PR 62 66 72 77 66 70 76 MBh 40.4 41.6 45.0 48.3 39.4 40.6 44.0 S/T 0.85 0.76 0.58 0.37 0.88 0.79 0.60 ∆T 20 19 15 10 20 19 15 2.22 2.28 2.36 2.45 2.42 2.48 2.58 1575 kW Amps 8.4 8.6 8.8 9.1 9.0 9.2 9.5 HI PR 133 143 151 157 149 160 169 LO PR 63 67 73 78 66 71 77 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 70 IDB 65 42.3 0.35 11 2.57 9.5 169 79 45.8 0.37 11 2.65 9.7 175 81 47.2 0.38 11 2.67 9.8 176 82 71 34.5 0.83 22 2.50 9.4 163 66 37.4 0.86 21 2.58 9.6 168 68 38.5 0.91 20 2.60 9.7 169 69 59 33.9 0.73 19 2.48 9.3 161 66 36.8 0.76 18 2.55 9.6 166 68 37.9 0.80 18 2.58 9.6 168 68 71 - 59 31.4 0.79 19 2.76 10.5 206 72 34.1 0.81 18 2.84 10.8 213 75 35.1 0.85 18 2.86 10.9 215 75 63 32.6 0.66 16 2.83 10.7 222 77 35.3 0.68 16 2.91 11.0 229 79 36.4 0.71 15 2.94 11.1 231 80 67 35.7 0.45 12 2.93 11.1 234 84 38.7 0.47 12 3.02 11.4 242 87 39.9 0.49 11 3.05 11.5 244 87 105 71 - 59 29.1 0.79 17 2.87 11.1 228 75 31.6 0.82 17 2.95 11.4 235 77 32.5 0.86 16 2.98 11.5 237 78 63 30.2 0.66 15 2.94 11.3 245 80 32.7 0.69 15 3.03 11.6 253 82 33.7 0.72 14 3.05 11.7 255 83 67 33.1 0.46 11 3.05 11.7 259 87 35.8 0.48 11 3.14 12.0 267 90 36.9 0.50 11 3.17 12.1 270 90 115 71 - 35.5 0.75 20 2.57 9.6 175 71 38.5 0.77 20 2.64 9.9 180 73 39.6 0.81 19 2.67 9.9 182 74 38.5 41.3 33.7 34.7 37.5 40.3 32.0 32.9 35.6 38.3 29.6 30.5 33.0 35.4 0.56 0.36 0.86 0.77 0.58 0.37 0.89 0.80 0.60 0.39 0.90 0.81 0.61 0.39 16 11 22 20 16 11 21 20 16 11 20 18 15 10 2.66 2.76 2.65 2.72 2.82 2.93 2.78 2.85 2.96 3.07 2.89 2.97 3.08 3.20 9.9 10.2 10.0 10.2 10.5 10.9 10.6 10.8 11.2 11.6 11.2 11.4 11.8 12.2 185 193 185 199 210 219 208 224 237 247 230 248 262 273 77 82 70 74 81 86 73 78 85 90 76 80 88 93 41.7 44.7 36.5 37.6 40.6 43.6 34.6 35.7 38.6 41.4 32.1 33.0 35.8 38.4 0.59 0.38 0.89 0.80 0.60 0.39 0.93 0.83 0.63 0.40 0.93 0.84 0.63 0.41 16 11 21 20 16 11 21 19 16 11 20 18 15 10 2.74 2.85 2.73 2.80 2.91 3.02 2.86 2.94 3.05 3.16 2.98 3.05 3.17 3.29 10.2 10.5 10.3 10.5 10.8 11.2 10.9 11.1 11.5 11.9 11.5 11.7 12.1 12.5 190 199 191 205 217 226 215 231 244 255 237 255 270 281 79 85 72 76 83 89 75 80 87 93 78 83 90 96 42.9 46.1 37.6 38.7 41.9 44.9 35.7 36.7 39.8 42.7 33.1 34.0 36.8 39.5 0.61 0.39 0.94 0.84 0.63 0.41 0.97 0.87 0.66 0.42 0.98 0.88 0.66 0.43 15 11 21 19 15 11 20 19 15 11 19 17 14 10 2.77 2.87 2.76 2.83 2.93 3.05 2.89 2.97 3.08 3.19 3.01 3.08 3.20 3.32 10.2 10.6 10.3 10.6 10.9 11.3 11.0 11.2 11.6 12.0 11.6 11.8 12.2 12.6 192 201 193 207 219 228 217 233 246 257 240 258 272 284 80 85 73 77 84 90 76 81 88 94 79 84 91 97 Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan) kW = Total system power Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 35.2 38.5 33.1 34.3 37.6 0.61 0.42 0.76 0.63 0.44 16 12 19 16 12 2.54 2.64 2.63 2.70 2.80 9.5 9.8 9.9 10.1 10.4 173 183 183 197 208 70 76 69 73 80 38.1 41.7 35.9 37.2 40.7 0.64 0.44 0.78 0.66 0.45 16 12 18 16 12 2.62 2.71 2.71 2.78 2.88 9.8 10.1 10.2 10.4 10.7 179 189 189 203 215 72 79 71 76 83 39.2 43.0 36.9 38.3 42.0 0.67 0.46 0.82 0.69 0.48 15 12 18 15 12 2.64 2.74 2.73 2.80 2.91 9.9 10.2 10.2 10.5 10.8 180 190 191 205 217 73 79 72 76 83 Expanded Cooling Data — GSC130421C* www.goodmanmfg.com SS-GSC13 SS-GSC13 Airflow 59 MBh 36.8 S/T 0.86 ∆T 24 2.16 1225 kW Amps 8.2 HI PR 129 LO PR 61 MBh 39.9 S/T 0.89 ∆T 23 2.22 1400 kW Amps 8.4 HI PR 133 LO PR 63 MBh 41.1 S/T 0.94 ∆T 22 1575 kW 2.24 Amps 8.5 HI PR 134 LO PR 64 63 37.6 0.81 23 2.21 8.4 138 65 40.8 0.84 22 2.28 8.6 143 67 42.0 0.88 22 2.30 8.6 144 68 67 71 40.2 43.0 0.66 0.5 20 16 2.30 2.4 8.6 8.9 146 152.5 71 75.5 43.6 46.6 0.68 0.5 19 16 2.36 2.5 8.8 9.1 151 157.2 73 77.8 44.9 48.0 0.71 0.5 19 15 2.38 2.5 8.9 9.2 152 158.8 74 78.6 59 36.0 0.89 24 2.36 8.8 144 64 39.0 0.92 24 2.42 9.0 149 66 40.1 0.97 23 2.45 9.1 150 67 63 36.8 0.84 23 2.41 9.0 155 69 39.8 0.87 23 2.48 9.2 160 71 41.0 0.91 22 2.51 9.3 162 71 75 67 39.3 0.68 20 2.50 9.3 164 75 42.6 0.71 20 2.58 9.5 169 77 43.8 0.74 19 2.60 9.6 171 78 MBh 37.5 38.2 40.0 42.7 36.6 37.3 39.1 S/T 0.90 0.87 0.79 0.64 0.93 0.90 0.81 ∆T 25 25 24 20 26 25 24 2.18 2.23 2.32 2.40 2.38 2.44 2.53 1225 kW Amps 8.3 8.4 8.7 9.0 8.9 9.1 9.3 HI PR 130 140 148 154 146 157 166 LO PR 62 66 72 76 65 69 76 MBh 40.6 41.4 43.3 46.2 39.7 40.4 42.3 S/T 0.94 0.90 0.81 0.66 0.97 0.94 0.84 ∆T 25 25 23 20 25 25 23 1400 kW 85 2.24 2.30 2.38 2.47 2.45 2.51 2.60 Amps 8.5 8.6 8.9 9.2 9.1 9.3 9.6 HI PR 134 144 152 159 150 162 171 LO PR 64 68 74 79 67 71 78 MBh 41.8 42.6 44.6 47.6 40.8 41.6 43.6 S/T 0.98 0.95 0.85 0.69 1.00 0.98 0.89 ∆T 24 24 22 19 24 24 23 2.26 2.32 2.41 2.50 2.47 2.53 2.63 1575 kW Amps 8.5 8.7 9.0 9.3 9.2 9.4 9.6 HI PR 135 146 154 160 152 163 173 LO PR 64 68 75 79 68 72 79 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 80 IDB 65 41.7 0.66 21 2.62 9.6 173 81 45.2 0.68 20 2.70 9.9 178 83 46.5 0.72 19 2.73 10.0 180 84 71 42.0 0.51 16 2.60 9.6 171 80 45.5 0.53 16 2.67 9.8 176 82 46.9 0.55 15 2.70 9.9 178 83 35.7 0.96 26 2.55 9.6 166 68 38.7 0.99 25 2.63 9.8 171 70 39.9 1.00 23 2.65 9.9 173 70 59 35.1 0.91 24 2.53 9.5 164 67 38.0 0.95 24 2.60 9.7 169 69 39.2 1.00 23 2.63 9.8 171 70 71 40.0 0.54 16 2.96 11.0 222 87 43.3 0.56 16 3.05 11.3 229 90 44.6 0.59 15 3.08 11.4 231 91 59 32.6 0.98 24 2.81 10.7 210 74 35.3 1.00 23 2.89 11.0 217 76 36.3 1.00 21 2.92 11.0 219 77 63 33.3 0.92 23 2.88 10.9 226 78 36.0 0.95 23 2.97 11.2 233 81 37.1 1.00 22 2.99 11.3 236 82 67 71 35.5 38.0 0.75 0.6 20 16 2.99 3.1 11.3 11.7 239 249.4 86 91.3 38.5 41.2 0.78 0.6 20 16 3.08 3.2 11.6 12.0 246 257.1 88 94.1 39.7 42.4 0.81 0.6 19 15 3.11 3.2 11.7 12.1 249 259.7 89 95.0 105 59 30.2 0.99 22 2.92 11.3 232 76 32.7 1.00 21 3.01 11.6 240 79 33.6 1.00 20 3.04 11.7 242 79 63 30.8 0.93 21 3.00 11.5 250 81 33.4 0.96 21 3.08 11.8 258 84 34.4 1.00 20 3.11 11.9 260 85 67 32.9 0.75 19 3.11 11.9 264 89 35.7 0.78 18 3.20 12.2 272 91 36.7 0.82 18 3.23 12.3 275 92 115 71 35.2 0.56 15 3.23 12.3 276 94 38.1 0.58 15 3.32 12.6 284 97 39.3 0.61 14 3.35 12.7 287 98 38.1 40.7 34.9 35.5 37.2 39.7 33.1 33.8 35.4 37.7 30.7 31.3 32.8 34.9 0.83 0.68 0.99 0.95 0.86 0.70 1.00 0.99 0.89 0.73 1.00 1.00 0.90 0.73 24 21 26 25 24 21 25 25 24 21 23 23 22 19 2.71 2.82 2.71 2.77 2.88 2.99 2.84 2.91 3.02 3.13 2.95 3.02 3.14 3.26 10.1 10.4 10.2 10.4 10.7 11.1 10.8 11.0 11.4 11.8 11.4 11.6 12.0 12.4 188 197 189 203 215 224 213 229 241 252 235 253 267 278 79 84 71 76 83 88 75 79 87 92 77 82 90 95 41.3 44.1 37.8 38.5 40.3 43.0 35.9 36.6 38.3 40.9 33.2 33.9 35.5 37.9 0.87 0.70 1.00 0.99 0.89 0.72 1.00 1.00 0.93 0.75 1.00 1.00 0.94 0.76 23 20 25 25 24 20 24 24 23 20 22 22 22 19 2.79 2.90 2.79 2.86 2.96 3.08 2.92 2.99 3.11 3.23 3.04 3.11 3.23 3.35 10.3 10.7 10.4 10.7 11.0 11.4 11.0 11.3 11.7 12.1 11.7 11.9 12.3 12.7 194 203 195 210 221 231 219 236 249 260 242 260 275 287 81 86 73 78 85 91 77 82 89 95 79 85 92 98 42.6 45.4 38.9 39.7 41.5 44.3 37.0 37.7 39.5 42.1 34.2 34.9 36.5 39.0 0.91 0.74 1.00 1.00 0.94 0.76 1.00 1.00 0.97 0.79 1.00 1.00 0.98 0.80 23 20 23 23 23 20 22 22 22 19 20 20 21 18 2.82 2.93 2.81 2.88 2.99 3.11 2.95 3.02 3.14 3.26 3.07 3.14 3.26 3.39 10.4 10.8 10.5 10.8 11.1 11.5 11.1 11.4 11.8 12.2 11.8 12.0 12.4 12.9 196 205 197 212 224 233 221 238 251 262 244 263 278 290 82 87 74 79 86 92 78 83 90 96 80 85 93 99 Shaded area reflects AHRI conditions Amps = outdoor unit amps (comp.+fan) kW = Total system power Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions 36.4 0.92 25 2.62 9.8 178 72 39.5 0.96 25 2.69 10.0 184 74 40.6 1.00 24 2.72 10.1 186 75 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 35.9 38.3 41.0 34.3 35.0 37.4 0.86 0.70 0.5 0.94 0.88 0.72 23 20 16 24 23 20 2.59 2.69 2.8 2.68 2.75 2.85 9.7 10.0 10.3 10.1 10.3 10.6 177 187 194.6 187 201 213 71 78 82.9 70 75 82 38.9 41.5 44.4 37.1 37.9 40.5 0.89 0.72 0.5 0.98 0.92 0.75 23 20 16 24 23 20 2.67 2.77 2.9 2.76 2.83 2.94 9.9 10.2 10.6 10.3 10.6 10.9 182 192 200.6 193 207 219 74 80 85.5 73 77 84 40.0 42.8 45.7 38.2 39.1 41.7 0.93 0.76 0.6 1.00 0.96 0.78 22 19 15 22 22 19 2.69 2.79 2.9 2.79 2.86 2.96 10.0 10.3 10.7 10.4 10.7 11.0 184 194 202.6 195 210 221 74 81 86.3 73 78 85 Expanded Cooling Data — GSC130421C* (cont.) www.goodmanmfg.com 13 14 Airflow MBh S/T ∆T 1400 kW Amps HI PR LO PR MBh S/T ∆T 1600 kW Amps HI PR LO PR MBh S/T ∆T 1800 kW Amps HI PR LO PR 59 40.8 0.68 18 2.46 9.9 127 60 44.2 0.71 18 2.53 10.1 131 62 45.5 0.74 17 2.56 10.2 132 62 63 42.3 0.57 16 2.52 10.1 136 63 45.8 0.59 16 2.60 10.4 140 65 47.2 0.62 15 2.62 10.4 142 66 67 46.3 0.40 12 2.62 10.4 144 69 50.2 0.41 12 2.69 10.7 148 71 51.7 0.43 11 2.72 10.8 150 72 71 - 59 39.9 0.71 19 2.69 10.6 142 63 43.2 0.73 18 2.76 10.9 146 65 44.5 0.77 17 2.79 11.0 148 66 63 41.3 0.59 16 2.75 10.9 153 67 44.8 0.61 16 2.83 11.1 158 69 46.1 0.64 15 2.86 11.2 159 70 75 67 45.3 0.41 12 2.86 11.2 161 73 49.0 0.43 12 2.94 11.5 166 75 50.5 0.45 11 2.97 11.6 168 76 MBh 41.5 42.7 46.2 49.6 40.5 41.7 45.2 S/T 0.78 0.69 0.53 0.34 0.81 0.72 0.55 ∆T 21 19 16 11 21 20 16 1400 kW 2.48 2.55 2.64 2.74 2.71 2.78 2.88 Amps 10.0 10.2 10.5 10.9 10.7 11.0 11.3 HI PR 128 138 145 152 144 154 163 LO PR 60 64 70 75 64 68 74 MBh 45.0 46.3 50.1 53.8 43.9 45.2 48.9 S/T 0.81 0.72 0.55 0.35 0.84 0.75 0.57 ∆T 21 19 16 11 21 19 16 2.56 2.62 2.72 2.82 2.79 2.86 2.97 75 1600 kW Amps 10.2 10.4 10.8 11.1 11.0 11.2 11.6 HI PR 132 142 150 156 148 159 168 LO PR 62 66 72 77 66 70 76 MBh 46.3 47.7 51.6 55.4 45.2 46.6 50.4 S/T 0.84 0.76 0.57 0.37 0.88 0.78 0.59 ∆T 20 18 15 10 20 19 15 1800 kW 2.58 2.65 2.75 2.85 2.82 2.89 3.00 Amps 10.3 10.5 10.9 11.2 11.1 11.3 11.7 HI PR 133 143 151 158 149 161 170 LO PR 63 67 73 78 66 71 77 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 70 IDB 65 48.5 0.35 11 2.99 11.7 170 79 52.5 0.36 11 3.08 12.0 175 81 54.1 0.38 11 3.11 12.1 177 82 71 39.6 0.83 21 2.91 11.6 163 66 42.9 0.86 21 3.00 11.9 168 68 44.2 0.90 20 3.03 12.0 170 69 59 38.9 0.73 19 2.88 11.5 162 66 42.2 0.75 18 2.97 11.8 167 68 43.4 0.79 18 3.00 11.9 168 68 71 - 59 36.1 0.78 18 3.21 13.0 207 72 39.1 0.81 18 3.30 13.3 213 74 40.2 0.85 17 3.34 13.4 216 75 63 37.4 0.65 16 3.29 13.3 223 77 40.5 0.67 16 3.39 13.6 230 79 41.7 0.71 15 3.42 13.8 232 80 67 41.0 0.45 12 3.41 13.7 235 84 44.4 0.47 12 3.52 14.1 243 86 45.7 0.49 11 3.55 14.2 245 87 105 71 - 59 33.4 0.78 17 3.34 13.7 229 75 36.2 0.81 17 3.44 14.1 236 77 37.3 0.85 16 3.47 14.2 238 78 63 34.6 0.66 15 3.42 14.0 246 79 37.5 0.68 15 3.52 14.4 254 82 38.6 0.71 14 3.56 14.6 256 83 67 37.9 0.45 11 3.55 14.5 260 87 41.1 0.47 11 3.66 14.9 268 89 42.3 0.49 11 3.69 15.0 271 90 115 71 - 40.7 0.74 20 2.99 11.8 176 70 44.1 0.77 19 3.07 12.2 181 73 45.5 0.80 19 3.10 12.3 183 73 44.1 47.3 38.6 39.7 43.0 46.2 36.7 37.8 40.9 43.9 34.0 35.0 37.9 40.6 0.56 0.36 0.85 0.76 0.58 0.37 0.88 0.79 0.60 0.39 0.89 0.80 0.60 0.39 16 11 22 20 16 11 21 20 16 11 20 18 15 10 3.10 3.22 3.09 3.17 3.29 3.41 3.24 3.32 3.45 3.58 3.37 3.46 3.59 3.72 12.2 12.7 12.3 12.6 13.0 13.5 13.1 13.4 13.8 14.3 13.8 14.2 14.6 15.2 185 193 186 200 211 220 209 225 238 248 231 249 263 274 77 82 70 74 81 86 73 78 85 90 75 80 88 93 47.8 51.3 41.8 43.1 46.6 50.0 39.7 40.9 44.3 47.5 36.8 37.9 41.0 44.0 0.58 0.37 0.88 0.79 0.60 0.38 0.92 0.82 0.62 0.40 0.93 0.83 0.63 0.40 16 11 21 20 16 11 21 19 16 11 20 18 15 10 3.19 3.31 3.18 3.26 3.39 3.52 3.34 3.42 3.55 3.69 3.47 3.56 3.69 3.84 12.6 13.0 12.7 13.0 13.4 13.9 13.4 13.8 14.2 14.7 14.2 14.6 15.0 15.6 191 199 192 206 218 227 216 232 245 256 238 256 271 282 79 84 72 76 83 89 75 80 87 93 78 83 90 96 49.2 52.8 43.1 44.4 48.0 51.5 40.9 42.1 45.6 48.9 37.9 39.0 42.2 45.3 0.61 0.39 0.93 0.83 0.63 0.40 0.96 0.86 0.65 0.42 0.97 0.87 0.66 0.42 15 11 20 19 15 11 20 19 15 10 19 17 14 10 3.22 3.34 3.21 3.29 3.42 3.55 3.37 3.45 3.58 3.72 3.50 3.59 3.73 3.87 12.7 13.1 12.8 13.1 13.5 14.0 13.6 13.9 14.3 14.9 14.3 14.7 15.2 15.7 193 201 194 208 220 229 218 234 247 258 241 259 273 285 80 85 72 77 84 90 76 81 88 94 78 83 91 97 Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan) kW = Total system power Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 40.3 44.2 38.0 39.3 43.1 0.61 0.42 0.75 0.63 0.43 16 12 19 16 12 2.96 3.07 3.06 3.14 3.26 11.7 12.1 12.2 12.5 12.9 174 184 184 198 209 70 76 69 73 80 43.7 47.9 41.1 42.6 46.7 0.63 0.44 0.78 0.65 0.45 16 12 18 16 12 3.04 3.16 3.15 3.23 3.35 12.1 12.4 12.6 12.9 13.3 179 189 190 204 216 72 78 71 75 82 42.4 43.9 48.1 45.0 49.3 0.66 0.46 0.82 0.68 0.47 15 12 18 15 12 3.07 3.19 3.18 3.26 3.38 12.2 12.6 12.7 13.0 13.4 181 191 192 206 218 73 79 72 76 83 Expanded Cooling Data — GSC130481C* www.goodmanmfg.com SS-GSC13 SS-GSC13 Airflow 59 MBh 42.2 S/T 0.85 ∆T 24 2.51 1400 kW Amps 10.0 HI PR 129 LO PR 61 MBh 45.8 S/T 0.88 ∆T 23 2.58 1600 kW Amps 10.3 HI PR 133 LO PR 63 MBh 47.1 S/T 0.93 ∆T 22 1800 kW 2.61 Amps 10.4 HI PR 135 LO PR 63 63 43.2 0.80 23 2.57 10.3 139 65 46.8 0.83 22 2.65 10.5 143 67 48.2 0.87 21 2.67 10.6 145 67 67 71 46.1 49.3 0.65 0.5 20 16 2.67 2.8 10.6 10.9 147 153.1 71 75.3 50.0 53.4 0.67 0.5 19 15 2.75 2.9 10.9 11.2 151 157.9 73 77.7 51.5 55.0 0.71 0.5 19 15 2.77 2.9 11.0 11.3 153 159.4 74 78.4 59 41.3 0.88 24 2.74 10.8 145 64 44.7 0.92 24 2.82 11.1 149 66 46.0 0.96 23 2.85 11.2 151 67 63 42.2 0.83 23 2.81 11.0 156 68 45.7 0.86 23 2.89 11.3 161 71 47.0 0.90 22 2.92 11.4 162 71 75 67 45.0 0.67 20 2.91 11.4 165 75 48.8 0.70 20 3.00 11.7 170 77 50.3 0.73 19 3.03 11.8 172 78 MBh 43.0 43.8 45.9 48.9 42.0 42.8 44.8 S/T 0.89 0.86 0.78 0.63 0.93 0.89 0.81 ∆T 25 25 23 20 26 25 24 2.53 2.60 2.69 2.80 2.76 2.83 2.94 1400 kW Amps 10.1 10.4 10.7 11.0 10.9 11.1 11.5 HI PR 130 140 148 155 146 158 166 LO PR 62 65 71 76 65 69 75 MBh 46.6 47.5 49.7 53.0 45.5 46.4 48.5 S/T 0.93 0.89 0.81 0.65 0.96 0.93 0.84 ∆T 25 24 23 20 25 25 23 1600 kW 85 2.61 2.67 2.77 2.88 2.85 2.92 3.03 Amps 10.4 10.6 11.0 11.3 11.2 11.4 11.8 HI PR 135 145 153 159 151 162 172 LO PR 63 67 74 78 67 71 78 MBh 48.0 48.9 51.2 54.6 46.8 47.7 50.0 S/T 0.97 0.94 0.85 0.69 1.00 0.97 0.88 ∆T 24 23 22 19 24 24 22 2.63 2.70 2.80 2.90 2.87 2.95 3.06 1800 kW Amps 10.5 10.7 11.0 11.4 11.3 11.5 11.9 HI PR 136 146 154 161 152 164 173 LO PR 64 68 74 79 68 72 79 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 80 IDB 65 47.8 0.65 21 3.05 11.9 174 80 51.8 0.68 20 3.14 12.2 179 83 53.3 0.71 19 3.17 12.3 181 84 71 48.1 0.50 16 3.02 11.8 172 80 52.2 0.52 16 3.11 12.1 177 82 53.7 0.55 15 3.14 12.2 179 83 41.0 0.95 26 2.97 11.8 167 68 44.4 0.98 25 3.06 12.1 172 70 45.7 1.00 23 3.09 12.2 173 70 59 40.3 0.91 24 2.94 11.7 165 67 43.6 0.94 24 3.03 12.0 170 69 44.9 1.00 23 3.06 12.1 172 70 71 45.9 0.53 16 3.45 13.6 223 87 49.7 0.55 16 3.55 14.0 229 90 51.2 0.58 15 3.58 14.1 232 90 59 37.3 0.97 24 3.27 13.2 211 74 40.4 1.00 23 3.37 13.6 218 76 41.7 1.00 21 3.40 13.7 220 77 63 38.1 0.91 23 3.35 13.5 227 78 41.3 0.94 22 3.45 13.9 234 81 42.6 1.00 22 3.49 14.0 237 82 67 40.7 0.74 20 3.48 14.0 240 85 44.1 0.77 19 3.59 14.3 248 88 45.5 0.81 19 3.62 14.5 250 89 105 71 43.6 0.6 16 3.6 14.5 250.4 91.0 47.2 0.6 16 3.7 14.9 258.1 93.9 48.6 0.6 15 3.8 15.0 260.7 94.8 59 34.6 0.98 22 3.40 14.0 233 76 37.5 1.00 22 3.50 14.3 241 78 38.6 1.00 20 3.54 14.5 243 79 63 35.3 0.92 21 3.49 14.3 251 81 38.3 0.95 21 3.59 14.7 259 84 39.4 1.00 20 3.63 14.8 262 84 67 37.7 0.75 19 3.62 14.8 265 88 40.9 0.77 18 3.73 15.2 273 91 42.1 0.81 17 3.77 15.3 276 92 115 71 40.3 0.56 15 3.76 15.3 277 94 43.7 0.58 15 3.87 15.7 285 97 45.0 0.61 14 3.91 15.9 288 98 43.7 46.7 40.0 40.7 42.7 45.5 38.0 38.7 40.5 43.3 35.2 35.9 37.6 40.1 0.83 0.67 0.98 0.95 0.85 0.69 1.00 0.98 0.89 0.72 1.00 0.99 0.89 0.72 24 21 26 25 24 21 25 25 24 20 23 23 22 19 3.16 3.28 3.15 3.23 3.35 3.48 3.30 3.39 3.52 3.65 3.44 3.52 3.66 3.80 12.4 12.9 12.6 12.8 13.3 13.7 13.3 13.6 14.1 14.6 14.1 14.4 14.9 15.4 189 197 190 204 216 225 213 230 242 253 236 254 268 279 78 84 71 75 82 88 74 79 86 92 77 82 89 95 47.4 50.6 43.3 44.1 46.2 49.3 41.1 41.9 43.9 46.9 38.1 38.9 40.7 43.4 0.86 0.70 1.00 0.98 0.89 0.72 1.00 1.00 0.92 0.75 1.00 1.00 0.93 0.75 23 20 25 25 24 20 24 24 23 20 22 22 22 19 3.25 3.38 3.24 3.32 3.45 3.58 3.40 3.49 3.62 3.76 3.54 3.63 3.77 3.91 12.8 13.2 12.9 13.2 13.6 14.1 13.7 14.0 14.5 15.0 14.5 14.8 15.3 15.9 195 203 196 210 222 232 220 237 250 261 243 262 276 288 81 86 73 78 85 90 77 82 89 95 79 84 92 98 48.8 52.1 44.6 45.5 47.6 50.8 42.4 43.2 45.2 48.3 39.3 40.0 41.9 44.7 0.90 0.73 1.00 1.00 0.93 0.75 1.00 1.00 0.96 0.78 1.00 1.00 0.97 0.79 22 19 23 23 23 20 22 22 22 19 20 20 21 18 3.28 3.41 3.27 3.36 3.48 3.62 3.43 3.52 3.65 3.80 3.57 3.66 3.80 3.95 12.9 13.4 13.0 13.3 13.7 14.2 13.8 14.1 14.6 15.1 14.6 14.9 15.4 16.0 197 206 197 213 224 234 222 239 252 263 245 264 279 291 82 87 74 79 86 91 77 82 90 96 80 85 93 99 Shaded area reflects AHRI conditions Amps = outdoor unit amps (comp.+fan) kW = Total system power Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions 41.8 0.92 25 3.04 12.1 179 72 45.3 0.95 25 3.13 12.4 185 74 46.6 1.00 24 3.16 12.5 187 75 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 41.2 44.0 47.0 39.3 40.1 42.9 0.85 0.69 0.5 0.93 0.88 0.71 23 20 16 24 23 20 3.02 3.13 3.2 3.12 3.20 3.32 12.0 12.3 12.8 12.4 12.7 13.1 177 187 195.4 188 202 213 71 78 82.7 70 75 82 44.6 47.6 50.9 42.6 43.5 46.5 0.88 0.72 0.5 0.97 0.91 0.74 23 20 16 24 23 20 3.10 3.22 3.3 3.21 3.29 3.42 12.3 12.7 13.1 12.8 13.1 13.5 183 193 201.5 194 208 220 73 80 85.3 72 77 84 45.9 49.1 52.4 43.8 44.8 47.9 0.92 0.75 0.6 1.00 0.95 0.78 22 19 15 22 22 19 3.13 3.25 3.4 3.24 3.32 3.45 12.4 12.8 13.2 12.9 13.2 13.6 185 195 203.5 196 210 222 74 81 86.1 73 78 85 Expanded Cooling Data — GSC130481C* (cont.) www.goodmanmfg.com 15 16 Airflow MBh S/T ∆T 1400 kW Amps HI PR LO PR MBh S/T ∆T 1600 kW Amps HI PR LO PR MBh S/T ∆T 1800 kW Amps HI PR LO PR 59 48.1 0.66 21 2.92 11.5 126 56 52.2 0.68 20 3.01 11.8 130 58 53.7 0.71 20 3.04 11.9 131 59 63 49.9 0.55 18 2.99 11.7 136 60 54.1 0.57 18 3.08 12.0 140 62 55.7 0.60 17 3.11 12.2 141 62 67 54.7 0.38 14 3.11 12.1 143 66 59.2 0.39 13 3.20 12.4 148 68 61.0 0.41 13 3.23 12.5 149 68 71 - 59 47.0 0.68 21 3.19 12.4 141 60 50.9 0.71 21 3.28 12.7 146 61 52.5 0.74 20 3.32 12.8 147 62 63 48.7 0.57 18 3.27 12.6 152 63 52.8 0.59 18 3.37 13.0 157 65 54.4 0.62 17 3.40 13.1 158 66 75 67 53.4 0.39 14 3.40 13.1 161 69 57.9 0.41 14 3.50 13.4 166 71 59.6 0.43 13 3.53 13.5 167 72 MBh 49.0 50.4 54.6 58.6 47.8 49.2 53.3 S/T 0.75 0.67 0.51 0.33 0.77 0.69 0.52 ∆T 24 22 18 13 24 22 18 2.95 3.02 3.14 3.26 3.22 3.30 3.43 1400 kW Amps 11.6 11.8 12.2 12.6 12.5 12.8 13.2 HI PR 127 137 145 151 143 154 162 LO PR 57 61 66 70 60 64 70 MBh 53.0 54.6 59.1 63.4 51.8 53.3 57.7 S/T 0.77 0.69 0.52 0.34 0.80 0.72 0.54 ∆T 24 22 18 12 24 22 18 1600 kW 75 3.04 3.11 3.23 3.35 3.32 3.40 3.53 Amps 11.9 12.2 12.5 13.0 12.8 13.1 13.5 HI PR 131 141 149 156 147 159 167 LO PR 59 63 68 73 62 66 72 MBh 54.6 56.2 60.9 65.3 53.4 54.9 59.5 S/T 0.81 0.73 0.55 0.35 0.84 0.75 0.57 ∆T 23 21 17 12 23 21 17 3.06 3.14 3.26 3.39 3.35 3.43 3.56 1800 kW Amps 12.0 12.3 12.6 13.1 12.9 13.2 13.6 HI PR 133 143 151 157 149 160 169 LO PR 59 63 69 73 63 67 73 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 70 IDB 65 57.2 0.34 13 3.56 13.6 169 74 62.0 0.35 12 3.67 14.0 175 77 63.8 0.37 12 3.70 14.1 176 78 71 46.7 0.79 24 3.46 13.5 162 63 50.6 0.82 24 3.56 13.9 168 65 52.1 0.86 23 3.60 14.0 169 65 59 45.9 0.70 21 3.43 13.4 161 62 49.7 0.72 21 3.53 13.8 166 64 51.2 0.76 20 3.56 13.9 167 64 71 - 59 42.5 0.75 21 3.82 15.2 206 68 46.1 0.78 21 3.93 15.6 212 70 47.5 0.81 20 3.97 15.7 215 71 63 44.1 0.62 18 3.91 15.5 222 73 47.8 0.65 18 4.03 16.0 229 75 49.2 0.68 17 4.07 16.1 231 76 67 48.3 0.43 14 4.06 16.0 234 79 52.3 0.45 13 4.18 16.5 241 82 53.9 0.47 13 4.23 16.6 244 82 105 71 - 59 39.4 0.75 20 3.97 16.1 228 71 42.7 0.78 19 4.09 16.5 235 73 44.0 0.82 18 4.13 16.7 237 73 63 40.8 0.63 17 4.07 16.4 245 75 44.3 0.65 17 4.19 16.9 253 77 45.6 0.68 16 4.23 17.1 255 78 67 44.8 0.44 13 4.23 17.0 259 82 48.5 0.45 13 4.35 17.5 267 84 49.9 0.47 12 4.40 17.6 269 85 115 71 - 48.1 0.71 22 3.55 13.8 175 67 52.1 0.74 22 3.66 14.2 180 69 53.6 0.77 21 3.69 14.3 182 69 52.0 55.8 45.5 46.9 50.8 54.5 43.3 44.5 48.2 51.7 40.1 41.3 44.7 47.9 0.54 0.35 0.82 0.73 0.55 0.36 0.85 0.76 0.58 0.37 0.86 0.77 0.58 0.37 18 13 24 23 18 13 24 22 18 13 23 21 17 12 3.68 3.83 3.67 3.77 3.91 4.06 3.85 3.95 4.10 4.26 4.01 4.11 4.27 4.43 14.3 14.8 14.4 14.8 15.2 15.8 15.3 15.7 16.2 16.8 16.2 16.6 17.1 17.8 185 193 185 199 210 219 208 224 237 247 230 248 261 273 73 77 66 70 76 81 69 73 80 85 71 76 83 88 56.4 60.5 49.3 50.8 55.0 59.0 46.9 48.3 52.2 56.1 43.4 44.7 48.4 51.9 0.56 0.36 0.85 0.76 0.57 0.37 0.88 0.79 0.60 0.38 0.89 0.80 0.60 0.39 18 12 24 22 18 13 24 22 18 12 22 20 17 12 3.79 3.94 3.78 3.88 4.03 4.18 3.97 4.07 4.23 4.39 4.13 4.24 4.40 4.57 14.7 15.2 14.8 15.2 15.7 16.2 15.7 16.1 16.6 17.3 16.7 17.1 17.6 18.3 190 199 191 205 217 226 215 231 244 254 237 255 269 281 75 80 68 72 79 84 71 76 82 88 73 78 85 91 58.1 62.3 50.8 52.3 56.6 60.8 48.3 49.7 53.8 57.7 44.7 46.0 49.8 53.5 0.58 0.38 0.89 0.80 0.60 0.39 0.92 0.83 0.63 0.40 0.93 0.83 0.63 0.41 17 12 23 21 17 12 23 21 17 12 21 20 16 11 3.83 3.98 3.82 3.92 4.07 4.22 4.01 4.11 4.27 4.43 4.17 4.28 4.44 4.61 14.8 15.3 14.9 15.3 15.8 16.4 15.9 16.3 16.8 17.4 16.8 17.2 17.8 18.4 192 201 193 207 219 228 217 233 246 257 240 258 272 284 76 81 68 73 79 85 72 76 83 89 74 79 86 92 Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan) kW = Total system power Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 47.6 52.1 44.8 46.4 50.9 0.58 0.40 0.72 0.60 0.42 18 14 21 18 14 3.52 3.65 3.64 3.73 3.87 13.7 14.1 14.3 14.6 15.1 173 183 183 197 208 66 72 65 69 76 51.5 56.5 48.5 50.3 55.1 0.60 0.42 0.75 0.62 0.43 18 14 21 18 14 3.62 3.76 3.75 3.84 3.99 14.1 14.5 14.7 15.0 15.5 178 188 189 203 215 68 74 67 71 78 53.1 58.2 50.0 51.8 56.8 0.63 0.44 0.78 0.65 0.45 17 13 20 17 13 3.65 3.79 3.78 3.88 4.03 14.2 14.7 14.8 15.2 15.7 180 190 191 205 217 69 75 68 72 79 Expanded Cooling Data — GSC130601D* www.goodmanmfg.com SS-GSC13 SS-GSC13 Airflow 59 MBh 49.8 S/T 0.82 ∆T 27 2.98 1400 kW Amps 11.7 HI PR 129 LO PR 58 MBh 54.0 S/T 0.85 ∆T 26 3.07 1600 kW Amps 12.0 HI PR 133 LO PR 59 MBh 55.6 S/T 0.89 ∆T 25 1800 kW 3.09 Amps 12.1 HI PR 134 LO PR 60 63 50.9 0.77 26 3.05 11.9 138 61 55.2 0.80 25 3.14 12.3 143 63 56.8 0.84 24 3.17 12.4 144 64 67 71 54.4 58.2 0.62 0.5 22 18 3.17 3.3 12.3 12.8 146 152.4 67 71.2 58.9 63.0 0.65 0.5 22 18 3.26 3.4 12.7 13.1 151 157.2 69 73.4 60.7 64.9 0.68 0.5 21 17 3.29 3.4 12.8 13.2 152 158.7 70 74.1 59 48.7 0.85 27 3.25 12.6 144 61 52.7 0.88 27 3.35 12.9 149 63 54.3 0.92 26 3.38 13.0 150 63 63 49.7 0.80 26 3.34 12.9 155 65 53.9 0.83 26 3.43 13.2 160 67 55.5 0.87 25 3.47 13.3 162 67 75 67 53.1 0.65 23 3.46 13.3 164 71 57.6 0.67 22 3.56 13.6 169 73 59.3 0.70 21 3.60 13.8 171 74 MBh 50.7 51.7 54.1 57.7 49.5 50.5 52.9 S/T 0.86 0.83 0.75 0.61 0.89 0.86 0.77 ∆T 29 28 27 23 29 28 27 3.01 3.08 3.20 3.32 3.28 3.37 3.49 1400 kW Amps 11.8 12.0 12.4 12.9 12.7 13.0 13.4 HI PR 130 140 148 154 146 157 166 LO PR 58 62 68 72 61 65 71 MBh 54.9 56.0 58.6 62.6 53.6 54.7 57.3 S/T 0.89 0.86 0.78 0.63 0.92 0.89 0.80 ∆T 28 28 26 23 28 28 26 1600 kW 85 3.09 3.17 3.29 3.42 3.38 3.47 3.60 Amps 12.1 12.4 12.8 13.2 13.0 13.3 13.8 HI PR 134 144 152 159 150 162 171 LO PR 60 64 70 74 63 67 74 MBh 56.6 57.7 60.4 64.4 55.3 56.3 59.0 S/T 0.93 0.90 0.81 0.66 0.97 0.93 0.84 ∆T 27 27 25 22 27 27 25 3.12 3.20 3.32 3.45 3.41 3.50 3.63 1800 kW Amps 12.2 12.5 12.9 13.3 13.2 13.5 13.9 HI PR 135 146 154 160 152 163 172 LO PR 61 64 70 75 64 68 74 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 80 IDB 65 56.4 0.63 23 3.63 13.9 173 76 61.1 0.65 23 3.74 14.3 178 78 62.9 0.68 22 3.77 14.4 180 79 71 56.8 0.48 18 3.59 13.8 171 75 61.5 0.50 18 3.70 14.1 176 78 63.4 0.53 17 3.74 14.3 178 78 48.3 0.91 29 3.53 13.8 166 64 52.4 0.95 28 3.63 14.1 171 66 53.9 0.99 27 3.67 14.3 173 66 59 47.5 0.87 27 3.50 13.6 164 63 51.5 0.90 27 3.60 14.0 169 65 53.0 0.95 26 3.63 14.1 171 66 71 54.1 0.51 18 4.10 15.9 222 82 58.6 0.53 18 4.22 16.4 228 85 60.4 0.56 17 4.26 16.5 231 86 59 44.0 0.93 27 3.89 15.5 210 70 47.7 0.97 27 4.01 15.9 217 72 49.1 1.00 25 4.05 16.0 219 72 63 45.0 0.87 26 3.99 15.8 226 74 48.7 0.91 25 4.11 16.3 233 76 50.2 0.95 24 4.15 16.4 236 77 67 48.1 0.71 22 4.14 16.3 239 81 52.1 0.74 22 4.27 16.8 246 83 53.6 0.77 21 4.31 16.9 249 84 105 71 51.4 0.5 18 4.3 16.9 249.3 86.1 55.7 0.6 18 4.4 17.4 257.0 88.7 57.3 0.6 17 4.5 17.6 259.5 89.6 59 40.8 0.94 25 4.05 16.3 232 72 44.2 0.97 25 4.17 16.8 240 74 45.5 1.00 23 4.21 17.0 242 75 63 41.7 0.88 24 4.15 16.7 250 77 45.2 0.91 24 4.28 17.2 258 79 46.5 0.96 23 4.32 17.4 260 80 67 44.5 0.72 21 4.31 17.3 264 84 48.2 0.74 21 4.44 17.8 272 86 49.7 0.78 20 4.48 17.9 275 87 115 71 47.6 0.54 17 4.48 17.9 275 89 51.6 0.56 16 4.61 18.4 284 92 53.1 0.58 16 4.66 18.6 287 93 51.6 55.1 47.2 48.1 50.3 53.7 44.8 45.7 47.8 51.0 41.5 42.3 44.3 47.3 0.79 0.64 0.94 0.91 0.82 0.67 0.98 0.94 0.85 0.69 0.99 0.95 0.86 0.70 27 23 29 29 27 23 29 28 27 23 27 26 25 22 3.76 3.90 3.74 3.84 3.99 4.14 3.93 4.03 4.18 4.35 4.09 4.19 4.35 4.52 14.5 15.1 14.7 15.0 15.5 16.1 15.6 16.0 16.5 17.1 16.5 16.9 17.5 18.1 188 196 189 203 215 224 212 229 241 252 235 253 267 278 74 79 67 71 78 83 70 75 82 87 73 77 84 90 55.9 59.7 51.1 52.1 54.5 58.2 48.5 49.5 51.8 55.3 45.0 45.8 48.0 51.2 0.82 0.67 0.98 0.94 0.85 0.69 1.00 0.98 0.88 0.72 1.00 0.99 0.89 0.72 26 23 29 28 27 23 28 28 26 23 26 26 25 21 3.87 4.02 3.86 3.96 4.11 4.26 4.05 4.15 4.31 4.48 4.21 4.32 4.48 4.66 14.9 15.5 15.1 15.4 15.9 16.5 16.0 16.4 16.9 17.6 17.0 17.4 17.9 18.6 194 203 195 209 221 231 219 236 249 260 242 260 275 287 76 81 69 74 80 86 72 77 84 90 75 80 87 93 57.6 61.4 52.6 53.6 56.2 59.9 50.0 51.0 53.4 56.9 46.3 47.2 49.4 52.7 0.86 0.70 1.00 0.99 0.89 0.72 1.00 1.00 0.93 0.75 1.00 1.00 0.93 0.76 25 22 27 27 26 22 26 26 25 22 24 24 24 20 3.91 4.06 3.89 3.99 4.15 4.31 4.08 4.19 4.35 4.52 4.25 4.36 4.53 4.70 15.1 15.6 15.2 15.6 16.1 16.7 16.2 16.6 17.1 17.7 17.1 17.5 18.1 18.8 196 205 197 212 223 233 221 238 251 262 244 263 278 290 77 82 70 74 81 86 73 78 85 91 76 81 88 94 Shaded area reflects AHRI conditions Amps = outdoor unit amps (comp.+fan) kW = Total system power Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions 49.3 0.88 28 3.62 14.1 178 68 53.4 0.91 28 3.73 14.5 184 70 55.0 0.96 27 3.76 14.6 186 71 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 48.5 51.9 55.4 46.4 47.4 50.6 0.82 0.66 0.5 0.90 0.84 0.69 26 23 18 27 26 23 3.58 3.72 3.9 3.71 3.80 3.95 14.0 14.4 14.9 14.5 14.9 15.4 177 187 194.5 187 201 212 67 73 78.2 66 71 77 52.6 56.2 60.1 50.2 51.3 54.8 0.85 0.69 0.5 0.93 0.87 0.71 26 22 18 27 26 22 3.69 3.83 4.0 3.82 3.92 4.07 14.3 14.8 15.3 14.9 15.3 15.8 182 192 200.6 193 207 219 69 76 80.6 68 73 80 54.2 57.9 61.9 51.7 52.9 56.5 0.89 0.72 0.5 1.00 0.92 0.75 25 21 17 26 25 22 3.73 3.87 4.0 3.86 3.96 4.11 14.5 14.9 15.5 15.1 15.4 15.9 184 194 202.6 195 209 221 70 76 81.4 69 74 80 Expanded Cooling Data — GSC130601D* (cont.) www.goodmanmfg.com 17 AHRI Ratings Indoor Units Cooling Ratings Outdoor Unit Coils/Air Handlers Total¹ Sens.¹ SEER² EER³ GSC130181F* CA*F1824*6B*+EEP 18,000 13,600 13 GSC130181G* CA*F1824*6B*+EEP 18,000 13,100 GSC130241F* CA*F1824*6B*+EEP 22,800 GSC130301(D,E)* CA*F3030*6B*+EEP GSC130361G* CFM AHRI # 11 600 4700185 13 11 600 5897360 17,600 13 11 800 4700186 27,600 21,000 13 11 950 4705227 CA*F3642*6C*+EEP 33,400 24,200 13 11 1,200 5528471 GSC130421C* CA*F4860*6B*+EEP 39,500 28,200 13 11 1,400 5528472 GSC130481C* CA*F4961*6A*+EEP 44,500 33,800 13 11 1,600 5528473 GSC130601D* CA*F4961*6A*+EEP 53,000 38,000 13 11 1,600 5528476 ¹ BTU/h ² Seasonal Energy Efficiency Ratio; tested and rated per AHRI 210/240 ³ Energy Efficiency Ratio @ 80 °F/67 °F Inside - 95 °F Notes • Always check the S&R plate for electrical data on the unit being installed. • When matching the outdoor unit to the indoor unit, use the piston supplied with the outdoor unit or that specified on the piston kit chart supplied with the indoor unit. • EEP: Order from Service Dept. Part No. B13707-38 or new Solid State Board B13707-35S. Part No. B13707-38 is not interchangeable with B13707-35S. The Goodman Gas Furnace contains the EEP cooling time delay. 18 www.goodmanmfg.com SS-GSC13 SS-GSC13 www.goodmanmfg.com YL T2 L2 T1 L1 1 SR BL IO CM AUX MAIN ALTERNATE DOUBLE POLE CONTACTOR 2 5 BK YL BK C COMP R AUX MAIN BL YL Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. BK BR PU RD CONTROL BOX S BK ⚠ L1 T1 BK YL RCCF RD SA (IF USED) NOTE 2 RD RD YL C BL RD BR F RD CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION. COMPONENT CODE C --------------- CONTACTOR CM ------------ OUTDOOR FAN MOTOR COMP -------- COMPRESSOR IO -------------- INTERNAL OVERLOAD LVJB ---------- LOW VOLTAGE JUNCTION BOX RCCF --------- RUN CAPACITOR FOR COMPRESSOR & FAN SA ------------- START ASSIST SC ------------- START CAPACITOR FOR COMPRESSOR (OPTIONAL) SR ------------- START RELAY FOR COMPRESSOR (OPTIONAL) FIELD WIRING HIGH VOLTAGE WIRING CODE FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE SEE NOTE 1 L1 C CM IO IO Y M AI N X AU SR S 2 SEE NOTE 1 C R COMP X AU M AI N 5 C F H 1 ⚡ USE N.E.C. CLASS 2 WIRE SC C (IF USED) SA RCCF OUTDOOR POWER SUPPLY SEE RATING PLATE 1) TO INDOOR UNIT LOW VOLTAGE TERMINAL BLOCK & INDOOR THERMOSTAT. 2) START ASSIST FACTORY EQUIPPED WHEN REQUIRED. 3) USE COPPER CONDUCTORS ONLY. NOTES: C T1 High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. EQUIPMENT GROUND SEE NOTE 3 H PU RD RD Warning C L2 T2 BK SC C COLOR CODE BK --------------- BLACK BL --------------- BLUE BR --------------- BROWN OR --------------- ORANGE PU --------------- PURPLE RD --------------- RED WH -------------- WHITE YL ---------------- YELLOW Y YL BL ALTERNATE DOUBLE POLE CONTACTOR ONLY LVJB C L2 0140R00015P-C T2 Wiring Diagram 19 Dimensions Dimensions Model W" D" H" GSC130181G* 26 26 27½ GSC130241F* 23½ 23½ 25¾ GSC130301E* 26 26 30¼ GSC130361G* 29 29 30¼ GSC130421BC* 29 29 30¼ GSC130481C* 29 29 36¼ GSC130601D* 29 29 40 Accessories Model Description ABK-20 ABK-21 Anchor Bracket Kit ▼ Anchor Bracket Kit ▼ ASC-01 CSR-U-1 CSR-U-2 CSR-U-3 FSK01A LSK01A 0263M00019 OT18-60A Anti-Short Cycle Kit Hard-start Kit Hard-start Kit Hard-start Kit Freeze Protection Kit 1 Liquid Line Solenoid Kit 2 Crankcase Heater Outdoor Thermostat GSC13 018** GSC13 024** GSC13 030** GSC13 036** GSC13 042** GSC13 048** GSC13 060** X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Contains 20 brackets; four brackets needed to anchor unit to pad ¹ Installed on indoor coil ² Field-installed, non-bleed, expansion valve kit — Condensing units and heat pumps with reciprocating compressors require the use of start-assist components when used in conjunction with an indoor coil using a non-bleed thermal expansion valve refrigerant metering device or liquid line solenoid kit. ▼ Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. © 2016 Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA. 20 www.goodmanmfg.com SS-GSC13