Transcript
Heating Programmer Comparison Guide
Room Thermostats and Heating Programmers Room Control
Room Control
Quick Comparison Chart
10 Great Reasons for Choosing Programastat en
e r g y s a v i ng
1
2
Latest benefits implementing the latest technology.
This ‘Quick Comparison Chart’ provides a ‘nearest to’ comparison to ProgramaStat. Competitors products listed may not have the same features, wiring or time periods. For full details see pages 3 to 6.
Complete range is all electronic.
Please compare the manufacturers technical data to ensure suitability. Whilst every care has been made compiling this chart Timeguard accept no responsibility for errors or omissions.
5
This easy to use guide shows you which Programastat heating controller is a perfect match. Often you can simply plug in without needing to rewire.
6 7
All you have to do is locate the existing programmer in the left hand column, then simply follow the line to the far right to find the recommended Programastat replacement.
TRT030
1
TRT031
10
TRT032
TRT033
H e l p l i n e & Te c h n i c a l S e r v i c e 0 2 0 8 4 5 0 0 5 1 5
TRT030
RTS1 RTS2 with LED
RET-B RET230P RTE230
4
Latest PID control.
Electronic frost thermostat with anti-tamper cover
TRT031
Wall mounting mechanical frost thermostat with anti-tamper cover
offer TRT031
9
Modern design family range.
Unique ‘Blueline’ temperature scale indicator.
TRT034
Electronic room thermostat
offer TRT030
Automatic summer/winter changeover.
Product features have been designed to cover the needs of the installer and user with simplicity in mind, all backed up by Timeguard’s three year product guarantee.
Danfoss Randall
Wall mounting mechanical room thermostat
1, 2, 3 & 4 Channel versions available.
Optimum Start thermostats.
ACL-Drayton (Invensys)
Easy to use & programme.
Large blue screen displays with backlighting.
8
Timeguard ProgramaStat
3 Whatever the central heating application you need to control, Timeguard can provide the answer with the new Programastat range. When replacing a central heating programmer don’t just fit what was there before, upgrade to Programastat.
Timeguard Description
TRT035
Fax 020 8450 0635
RMT230
RTS 3
Honeywell
T6360B (cover extra)
Horstmann
HRT2 HRT3
RET230F5 (fixed temp)
Sunvic (Formally Satchwell)
Potterton / Myson
Salus
Siemens (Landis & Staefa, Landis & Gyr)
TLX5101 TLX5301
PRT1
RT200
RDD10
TLX2259 TLX2356
MRT1
RT100
RAA20
TLX5101
FT100
TLM2257 TLX2360
T4360
RAD1 (fixed temp)
Digital room thermostat with night set back
TRT033
Digistat+
RT51
DT90E
DRT1
TLX7501
RT300
RDH10
7 day digital programmable room thermostat with frost protection
TRT035
Digistat+3
TP5000 TP7000
CM907
CentaurStat 7 DRT2 AS2
TLX6501 and SIMPRO
RT500
RDJ10 REV200 REV24
Wireless 7 day digital programmable room thermostat with frost protection
TRT037
Digistat+3 RF RF700SX
TP7000RF + RX1
CMT927
AS2RF
TLX RFP
RT500RF
RDJ10RF REV200RF REV24RF
7 day (or 5+2 day) digital 1 channel programmer for central heating
TRT034
LP711 Tempus 1 Tempus 2
ST715Si GP103E7
ST9100C
CentaurPlus C17 ChannelPlus H17XL
107XLS
EP4002 EP5002 MEP1C
EP100
RWB7 RWB27
7 day (or 5+2 day) digital 2 channel programmer for central heating and hot water
TRT036
LP522 LP722 Tempus 6 Tempus 7
CP715 FP75 FP715 FP715si FP975 GP102E5
ST6400C ST9400C ST799A
CentaurPlus C27 ChannelPlus H27 H27XL and H27ZXL
207XLS
MEP2C MEP20 EP3002 EP6002
EP200
RWB20 RWB29 RWB252
7 day (or 5+2 day) digital 3 channel programmer for central heating and hot water
TRT038
ChannelPlus H37XL ChannelPlus H37VXL
307XLS
7 day (or 5+2 day) digital 4 channel programmer for central heating and hot water
TRT039
ChannelPlus H47XL
Cylinder/Pipe thermostat
TRT044
HTS3...PTS1
SA2452
MCT1
CT100
RAM1
Wiring centre box
TRT049
LWC1
SWC2202
MWB16
TC100
JB1
TRT036
TRT037
ATC….ATP
LA641 LA6190B
HCT2
42005748-001
TRT038
Email
[email protected]
TRT039
TRT044
TRT049
Website www.timeguard.com
2
Heating Programmer Comparison Guide
Timeguard
ACL-Drayton
Danfoss Randall
ProgramaStat TRT036
•
•
•
ProgramaStat TRT037
•
•
•
ProgramaStat TRT038
•
•
•
ProgramaStat TRT039
•
•
•
FP LP111 LP112 LP241 LP522 LP711 LP722 LS111 LS112 LS241 LS522 LS711 LS722 MP Switchmaster 300 Switchmaster 320 Switchmaster 350 Switchmaster 400 Switchmaster 600 Switchmaster 805 Switchmaster 900 Switchmaster 9000 Switchmaster 9001 Switchmaster 905 Switchmaster 980 Switchmaster Sonata TC Tempus 1 Tempus 2 Tempus 3 Tempus 4 Tempus 6 Tempus 7 102 102E 102ES 102E7 103 103E 103ES 103E7 3001 3002 3020P 3033
• • • • • • • • • • • • • • • • • • • • • • • • •
• • • •
• • • • • • • • • • • • • • • • • •
• • •
•
•
• • • • • • • • • • • • •
Wireless
Programmable Thermostat
Common Time Base
Mini-Programmer
Programmer • • •
•
•
•
• •
•
• •
• • •
•
• • •
•
• •
•
• • • • •
• • • • • • • • •
• • • • •
• • • •
• • • • • • •
• • • • • • • • • • • • • • • • • • •
•
• •
•
• •
• • • •
• • • • • • • • • • • •
• •
Timeswitch
•
•
Recommended Replacement
•
•
• •
• • • • • • • • • • • •
•
• •
•
• • •
• • • • • • •
• • • • • • • •
• • • • •
• • • •
• • • • • • • •
• • • • • • • •
•
•
•
•
•
Replace with 7 day TRT036 Replace with 7 day TRT034 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT034 TRT036 Replace with 7 day TRT034 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT034 TRT036 Replace with 7 day TRT036 Replace with 7 day TRT034 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT034 TRT036 Replace with 7 day TRT034 Replace with 7 day TRT034 Replace with 7 day TRT034 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT034 Replace with 7 day TRT034 Replace with 7 day TRT034 Replace with 7 day TRT034 Replace with 7 day TRT034 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036
Danfoss Randall
Glowworm
Honeywell
Horstmann
ProgramaStat TRT035
•
•
•
ProgramaStat TRT036
•
•
•
ProgramaStat TRT037
•
•
•
ProgramaStat TRT038
•
•
•
•
•
3060 4033 701 702 911 917 922 971 972 CP15 CP75 CP715 FP15 FP75 FP715 FP975 MP15 MP75 SET1 SET1E SET2 SET2E SET3E SET3M SET4 SET5 TS15 TS75 TS715 TS975 Masterminder ST1000 ST1501 ST1507 ST6100A ST6100C ST6200A ST6300A ST6400C ST6450B ST6998 Fully Pumped ST6998 Gravity ST7000A ST7000B ST7100 ST799A 423 Amethyst 10 423 Amethyst 7 423 Diamond 423 Emerald 423 Pearl Auto 424 Coral 424 Diamond 424 Emerald 424 Gem 424 Pearl Auto 425 Coronet 425 Diadem
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
• • • • • •
• •
• •
• •
• • •
• • • • • • • • • • •
• • • •
• •
• • •
• • •
• •
Programmer
Mini-Programmer
Timeswitch
1.5 Circuits
Two Circuit
•
•
• •
• •
• • •
• • •
• •
• • • • • •
• •
• •
• •
• • • •
• • • •
•
•
• • • •
• •
• • •
• •
•
• • •
• • • •
• • • • • • • •
• • • •
• • •
•
• • • • •
• •
• • • • • •
• •
• • •
• • • •
• • •
• • • •
• •
•
• • • • • • • • • • • •
• • • • • • • • • • • • •
• •
• •
• • • • •
•
• •
•
•
•
• • •
• • • • •
• •
•
•
• • • • • • • • • • • •
•
• • • • • •
• • • • •
•
•
• •
• •
•
Recommended Replacement
•
•
• • •
•
• •
•
• •
Single Circuit
•
Four Channel
Single Channel
•
Three Channel
7 Day
•
Two Channel
5/2 Dday
•
ProgramaStat TRT039
•
•
•
Timeguard
•
•
• •
• •
1.5 Circuits
•
Model ProgramaStat TRT034
•
•
•
Manufacturer
•
•
• • • •
Two Circuit
Single Circuit
Four Channel
• •
•
• • • •
• •
• • •
• •
Three Channel
•
Two Channel
Single Channel
• •
5/2 Day • •
24 Hour
• •
Electronic
ProgramaStat TRT034 ProgramaStat TRT035
Model
Mechanical
Manufacturer
7 Day
The information contained in this comparison guide is intended for guidance only and is believed to be correct. Timeguard can accept no liability for any errors or omissions and reserve the right to make changes at any time without notice. Installation and connection should only be carried out by a suitably qualified person and in accordance with the current edition of the IEE wiring regulations.
24 Hour
Use ProgramaStat as a general replacement for all your applications. Please check the technical details in the brochure or download the instruction sheets from our website www.timeguard.com
Electronic
Timeguard recommend replacing a 24hour or 5-2 day programmer with the 7day/5-2 day electronic programmer listed below, as it may be used in the same way. If required please call our Helpline for assistance on 020 8450 0515.
Mechanical
Recommended Replacement
Common Time Base
Electronic Heating Programmer Replacement Chart
Wireless
Room Control Programmable Thermostat
Room Control
•
• •
• • •
• • • • • •
• •
• • • • •
• • • •
•
• •
•
•
•
•
• • •
•
• •
• •
• •
• • •
Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT034 Replace with 7 day TRT034 Replace with 7 day TRT036 Replace with 7 day TRT034 TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT034 Replace with 7 day TRT034 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT034 Replace with 7 day TRT036 Replace with 7 day TRT034 Replace with 7 day TRT034 Replace with 7 day TRT034 Replace with 7 day TRT034 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 TRT036 Replace with 7 day TRT034 Replace with 7 day TRT034 Replace with 7 day TRT036 Replace with 7 day TRT036 TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT034 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT034 Replace with 7 day TRT034 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT034 Replace with 7 day TRT036 Replace with 7 day TRT034 Replace with 7 day TRT034 Replace with 7 day TRT036 Continued on next page.
3
H e l p l i n e & Te c h n i c a l S e r v i c e 0 2 0 8 4 5 0 0 5 1 5
Fax 020 8450 0635
Email
[email protected]
Website www.timeguard.com
4
Heating Programmer Comparison Guide
Timeguard
Horstmann
Siemens Landis & Gyr Landis & Staefa
Myson
Pegler Sunvic
Potterton
5
ProgramaStat TRT036
•
•
•
ProgramaStat TRT037
•
•
•
ProgramaStat TRT038
•
•
•
ProgramaStat TRT039
•
•
•
425 Tiara 517 525 527 Centaur SC1 Centaur SC7 Centaur TC1 Centaur TC7 CentaurPlus C11 CentaurPlus C17 CentaurPlus C21 CentaurPlus C27 ChannelPlus H11XL ChannelPlus H17XL ChannelPlus H21XL ChannelPlus H27ZXL ChannelPlus H27XL ChannelPlus H37XL ChannelPlus H37VXL ChannelPlus H47XL RWB100 RWB102 RWB152 RWB170 RWB2 RWB20 RWB200 RWB252 RWB270 RWB3 RWB30 RWB40 RWB50 RWB7 RWB9 Microtimer One Microtimer Seven MP2 Select 107 Select 207 SP100 SP2 SP20 SP25 SP30 SP35 SP50 EP2000 EP2001 EP2002 EP3000 EP3001 EP3002 EP4000 EP4001
•
• • • • • • • • • • • • • • • • • • • • • • • •
•
•
• • • •
•
• •
• • • • • • • • • • • • • • • • • • • • • • • • • •
• •
• • • • • • •
• •
• •
• • • •
•
• • •
• • • • •
• • • •
• • • •
• • •
• • • • • • •
• •
• •
•
• • • • • • •
• • • • • • • •
• • • • •
• • •
•
• • •
• •
• • • •
•
•
• • • •
• • • • • • • • • • • •
•
• • • • •
• •
• • • • • • • • • • • • • •
• •
• • • • •
• • •
• •
• • •
•
• • •
• • • • • • • • •
• • • • • • • • •
• •
H e l p l i n e & Te c h n i c a l S e r v i c e 0 2 0 8 4 5 0 0 5 1 5
C • • • • • •
•
Replace with 7 day TRT036 Replace with 7 day TRT034 Replace with 7 day TRT036 TRT036 Replace with 7 day TRT034 Replace with 7 day TRT034 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT034 TRT034 Replace with 7 day TRT036 TRT036 Replace with 7 day TRT034 TRT034 Replace with 7 day TRT036 TRT036 TRT036 TRT038 TRT038 TRT039 Replace with 7 day TRT034 Replace with 7 day TRT036 Replace with 7 day TRT034 Replace with 7 day TRT034 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 TRT036 Replace with 7 day TRT034 Replace with 7 day TRT034 Replace with 7 day TRT034 Replace with 7 day TRT034 Replace with 7 day TRT034 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT034 Replace with 7 day TRT036 TRT036 Replace with 7 day TRT036 Replace with 7 day TRT034 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT034 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT034 Replace with 7 day TRT034
Fax 020 8450 0635
Potterton
Salus
Sangamo
Smiths Industries
Towerchron
Venner
ProgramaStat TRT035
•
•
•
ProgramaStat TRT036
•
•
•
ProgramaStat TRT037
•
•
•
ProgramaStat TRT038
•
•
•
ProgramaStat TRT039
•
•
•
EP4002 EP5002 EP6000 EP6002 Mini Minder Mini Minder E Mini Minder ES EP100 EP101 – voltage free EP200 RT500RF – voltage free RT500 – voltage free 409 form 8 410 form 8 M5 M6 Centroller 100 Centroller 1000 Centroller 30 Centroller 40 Centroller 50 Centroller 60 Centroller 70 Centroller 90 Centroller MK1 Centroller MK2 DP72 DT71 QE1 QE2 T2001 T2001Q T2002 T2002Q T2003 T2003Q CHC/W2 Venetrol 80 Venetrol 80M Venetrol 80P Venetrol 80P/M Venner T10 Venner T20 Venner T30 Venotime
• • • •
•
• • •
• • • • • •
• • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • •
• • • • •
• • • • • • • • • • • • • • •
Common Time Base
Programmer
Mini-Programmer
Timeswitch
1.5 Circuits
Two Circuit
•
• •
•
•
•
•
•
• • •
• • • • • • •
• • • • • •
• • • •
• • • •
• • •
•
• •
•
• • •
•
• •
• •
•
• • •
• • • • •
•
•
•
• •
• • •
•
• • •
• •
• •
• • • • • • • • • • • • • • •
•
• •
•
•
• •
•
• • • •
• •
•
• •
• •
Recommended Replacement
•
• •
• • • • • • • • • • • • • • • • • •
Single Circuit
•
Four Channel
•
Three Channel
Single Channel
•
Two Channel
7 Day
•
5/2 Day
24 Hour
Electronic
Mechanical
Wireless
Programmable Thermostat
Common Time Base
Programmer
Mini-Programmer
• •
• •
• •
•
•
• •
• • •
•
• •
• •
•
• •
•
•
• • • • • •
• • • • • • • •
•
•
• • • • • • •
Timeguard
•
• •
• • • • •
Recommended Replacement
•
• •
•
• •
• •
Model ProgramaStat TRT034
•
•
• •
Manufacturer
•
•
•
• • • • •
• •
• •
• •
• •
Timeswitch
•
1.5 Circuits
•
Two Circuit
•
Single Circuit
ProgramaStat TRT035
Four Channel
•
Three Channel
Single Channel
•
Two Channel
7 Day
•
24 Hour
•
Electronic
ProgramaStat TRT034
Model
Mechanical
Manufacturer
5/2 Day
Electronic Heating Programmer Replacement Chart (continued)
Wireless
Room Control Programmable Thermostat
Room Control
• • •
•
• •
• • • •
• •
• • • • • • • •
• • • • • • •
• • • • • • • • •
• •
• •
• • •
•
•
Replace with 7 day TRT034 Replace with 7 day TRT034 TRT036 TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT034 TRT034 Possibly TRT034 but not voltage free TRT036 Possibly TRT035 but not voltage free Possibly TRT037 but not voltage free Replace with 7 day TRT034 Replace with 7 day TRT034 Replace with 7 day TRT036 Replace with 7 day TRT034 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT034 Replace with 7 day TRT034 Replace with 7 day TRT034 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT034 Replace with 7 day TRT034 TRT036 Replace with 7 day TRT036 Replace with 7 day TRT034 TRT036 Replace with 7 day TRT034 Replace with 7 day TRT034 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT034 Replace with 7 day TRT036 Replace with 7 day TRT036 Replace with 7 day TRT034
Notes Important: Installation and connection should be undertaken by a suitably qualified person in accordance with the IEE Wiring Regulations. Before removing any exsisting programmer note the wire colours, terminal positions and numbers in relation to the existing backplate then ensure the replacement unit is correctly terminated. Any spare wires, maybe formally connected into linking terminals, should be connected into a separate terminal block (not supplied), wires from different spare terminals should not be joined together. Whilst every care has been made compiling this chart from previously held data Timeguard can accept no reponsibility for errors or omissions. The Timeguard cat no TRT038 and TRT039 three and four channel 7 day heating programmers are designed for fully pumped systems. The Timeguard cat no TRT036 two channel 7 day heating programmer is designed for either pumped or gravity fed systems. All Timeguard digital heating programmers have AUTOMATIC summer-winter time change, ADVANCE and BOOST facility. Surface mounting over standard BS box fixings.
TRT030
TRT031
TRT032
TRT033
TRT034
TRT035
Email
[email protected]
TRT036
TRT037
TRT038
TRT039
TRT044
Website www.timeguard.com
TRT049
6
Replacement Programmer Wiring Guide Before removing any existing programmer it is essential to make a note of wire colours, terminal positions and numbers in relation to the existing backplate. The charts below only include programmers or timeswitches where wiring changes are necessary when fitting our recommended replacement. Where a direct plug-in replacement is available or where terminal connections do not change the appropriate replacement is shown on the Electronic Heating Programmer Replacement Chart (pages 3 to 6). Make and Reference Number
HW OFF
CH OFF
HW ON
CH ON
E
N
L
HW OFF
CH OFF
HW ON
CH ON
E
N
L
TRT034
–
NC1
–
NO1
–
N
L
NC2
NC1
NO2
NO1
–
N
L
–
–
2
5
–
N
L 7
Make and Reference Number
Timeguard Single Channel
TRT034
–
NC1
–
NO1
–
N
L
Timeguard Single Channel
Timeguard Two Channel
TRT036
NC2
NC1
NO2
NO1
–
N
L
Timeguard Two Channel
TRT036
Sangamo
409-1
Siemens... Landis & Gyr, Landis & Staefa
RWB2/20/40/ 200/252/270/XP/9
ACL-Drayton… ...Invensys
MP
1 –
FP
Horstmann
–
N
L
10
–
2
1
409-3
4
2
5
1
–
*N,1,3
409-4
–
–
2
5
–
3, 6
L
410-1
2
7
1
8
–
*N,1,3
3,6
11
6
10
–
2
1
HW ON
CH ON
410-2
2
7
-
8
–
4,5
1,3,6
2000
CH OFF
–
N
L
410-3
1
2
7
8
–
4,5
6
112
–
–
3
4
–
N
L
414
2
7
1
8
–
4,5
3
DHP2301
8
5
6
3
–
1
2
L
ET1401/1451
8
5
7
4
–
1
2
L
SP2
1
4
3
6
–
N
L
SP50
1
4
2
5
–
N
3 L
Mastermind
1 1 1
2 2 2
3 3 3
4 4 4
– – –
N N N
L
ST499A
–
–
6
3
–
N
L
ST6998B/ST699C
7
4
6
3
–
N
L
ST6300A/ST6400C
1
2
3
4
–
N
L
ST7100
7
4
8
5
–
N
L
525/527
3
6
1
4
–
N
L
Centaur TC1/TC7
2
–
3
4
–
N
L
Sunvic (Satchwell)
Smiths Industries
Switchmaster
SP100
1
4
2
5
–
N
Centroller 10/100
–
–
3
2
–
N
L
Centroller 60/70/90
–
–
4
5
–
1
2
Superswitch
–
–
4
1
–
2
3
320
–
–
3
1
–
N,2
L
–
–
3
1
–
N,2
L
Diadem/Tiara
3
6
1
4
–
N
L
350
Gem
6
9
4
7
–
2
1
400/600
–
–
3
1
–
N
L
Diamond 423
–
–
2
4
–
N
L
–
–
3
4
–
N,1,8
L,2,9
800/805/900/905/ 9000/9001
423/424
-
-
7,8
4
–
2,3
1
Mini-Minder
1
2
3
4
–
*N
L
EP2000/3000/2001/ 3001/6000
1
2
3
4
–
N
L
Potterton / Myson 411
Danfoss Randall
6
4
8
Tempus 314/7 Honeywell
–
3
HW OFF
241/522/722 Glowworm
2
102
–
–
1
2
–
5
4
2
3
1
–
N
L
Sonata Symphony 900/9000/9001
3
6
1
4
–
N
L
Tower
DP72
1
2
3
4
–
#N
L
AMF Venner
CHC / W2/80
–
–
2
AS
–
$N,1,3,4
L
T20/T30
–
–
2
6
–
$N,2,3
L
80M/80PM
1
4
2
AS
–
#N,3
L
80P
–
–
2
AS
–
#N,1,3
L
6
3020P
–
–
4
2
–
7,1
6
3033
5
3
4
2
–
7,1
6
3060
–
–
4
2
–
7,1
6
Set2/Set5
3
6
1
4
–
N
L
4033
5
3
4
2
–
N
1,6
701/702
4
2
3
1
–
N
L
# On Venner units (AS) terminals X2 if both wired. One goes to CH ON (NO1) on TRT036 and you will have to link the remaining (AS) terminal and the wire from terminal 5 together.
922/972
1
4
3
6
–
N
L
$ Link wires 5+4 from the old unit in a separate terminal block together.
Notes When replacing the Siemens RWB20 a neutral connection to the backplate is required. * Link old 4+6 in separate terminal block.
Important Whilst we have tried to ensure accuracy, this chart was compiled from previously held data and may contain errors, please check carefully and ensure no links have been omitted. Timeguard can accept no responsibility for errors or omissions. Please ensure you have used the correct data and check that all screws are tight. Installation should be carried out by a suitably qualified person in accordance with the IEE Wiring Regulations.
Sales Office Direct Line Tel: 020 8452 1112 Fax: 020 8450 0635 E-mail:
[email protected]
Helpline & Technical Service Direct Line Tel: 020 8450 0515 Fax: 020 8450 0635 E-mail:
[email protected]
General Enquiries Tel: 020 8450 8944 Fax: 020 8452 5143 E-mail:
[email protected] Website: www.timeguard.com
Zerofour – January 2010