Preview only show first 10 pages with watermark. For full document please download

H4650 Ln4650 0 675 90 Outside The Door Indicator Bus

   EMBED


Share

Transcript

0 675 90 Outside the door indicator BUS-SCS Description Front view Outside the door indicator with “Do Not Disturb” or “Make Up Room” notifications; it also has a call bell pushbutton and white backlit notification to indicate if someone is in the room, and the presence of alarm conditions. If the DND function is active, the call pushbutton is disabled. The white backlight switch on function can be configured for operating in different modes. See the physical configuration section “L configurator”. The “Visual alarm notification” function outside the door is only available for systems with the MH201 device installed, and its programming is only possible using the MyHOME_Suite software. This function is only available for devices with lot number 14w40 or later. The device can be configured in two different ways: - Physical configuration, by inserting the configurators in the appropriate housings. - Configuration using the MyHOME_Suite software, which can be downloaded from the website www.homesystems-legrandgroup.com; this last type of configuration has the advantage of offering many more options when compared with the physical configuration. 1 4 H4650 LN4650 2 3 Rear view 5 Technical data Power supply from SCS BUS: Stand-by absorption: Relay contact (activated by the front pushbutton): Operating temperature: 18 – 27 Vdc 10 mA 20 mA max 12 Vac/dc – 230 Vac 1A max 5 – 40 °C Standards, Certifications, Marks 7 6 Legend 1. DND indicator (red LED on = DO NOT DISTURB) EN 60669-2-1 EN 50491-5-1 EN 50428 2. MUR indicator (green LED on = MAKE UP ROOM) 3. Call pushbutton 4. Room number customisable and backlit area with white notification for: guest in the room and alarm notification Dimensional data 5. Configurator socket 6. Clamps for connection to the SCS BUS Size: 2 flush mounted modules 7. NO contact for the activation of the bell. The contact is controlled by the front pushbutton MM00774-b-EN 15/01/2015 1 Outside the door indicator BUS-SCS 0 675 90 Physical configuration H4650 LN4650 Wiring diagrams Room 127 bell control diagram The bell is active while the relevant key on the device is pressed. R1 R2 M 230 Vac L R1, R2 = Room address (R1 identifies the tenths; R2 identifies the units) Transformer Room bell 12 Vac/dc – 230 Vac 1A max M = 0 for use together with F420 M = 1 for use together with MH200N M = 2 for use together with MH201 L = LED functions L CONFIGURATOR 0 1 2 3 4 5 6 7 WHITE BACKLIGHTING LED ON: occupied OFF: free ON: occupied OFF: free ON: free OFF: occupied ON: free OFF: occupied Always ON Always ON Always OFF Always OFF RED DND LED Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled GREEN MUR LED Enabled Disabled Enabled Disabled Enabled Disabled Enabled Disabled R1 R2 M L = = = = 2 7 2 0 L1 L2 H4650 LN4650 0 675 90 BUS-SCS Configuration using the MyHOME_Suite software This is performed using the appropriate MyHOME_Suite application. This mode has the advantage of offering many more options when compared with the physical configuration. The software configuration requires Ethernet connection between the system and the PC, through the IP MH201 scenario module. Ethernet connection to the system Ethernet network MH201 Switch layer 3 MH201 Ethernet network BUS-SCS PC for configuration MM00774-b-EN 15/01/2015 2 MM00774-b-EN Ethernet network 230 Vac PC for room management Other rooms Switch layer 3 R1 R2 M L A PL T Bell 12 Vac/dc – 230 Vac max 1A Ethernet network = = = = = = = 2 7 2 0 1 1 2 MH201 A N L H4650 LN4650 0 675 90 Transformer GS (TM+EL) L1 L MH201 230 V 50 Hz F E49 SCS: 27 Vdc 600 mA PRI: 220 – 240 V~ 185 – 175 mA 50/60 Hz E49 PRI SCS B TM2 A =9 PL = 9 M1 = CEN DEL1= – M2 = – DEL2= – H4649 LN4649 0 675 65 5 727 35 5 722 35 To other room services C TM1 WINDOW OPEN WINDOW CLOSED Protection line Magnet R1 = 2 R2 = 7 M = – DND H4653 LN4653 0 675 93 ECO ON NC contact Contact MUR Contact FAN – A = PL = M = LED = 9 8 CEN – H4652 LN4652 0 675 92 ZA = 2 ZB = 7 + TYPE = 1 HEAT = 7 COOL = CEN H4691 PUMP = – LN4691 IN = 3 0 674 59 MODE 3513 Magnet D TM3 To other devices BUS SCS = = = = 2 7 1 – DESCRIPTION Power supply Outside the door indicator Key card switch DND and MUR controls 8 key scenario control Thermostat with display IP scenario module Air conditioning actuator ROOM CORRIDOR RECEPTION ZA ZB N LOAD E F430R8 To the fan-coil or temperature control system C D The general switch GS (TM+EL) must be selected based on the absorption of the services installed. The TM switch must be selected based on the power supply used. The TM switch must be selected based on the loads connected. The actuator to be used depends on the type of air conditioning system installed. If the current supplied by the E49 is not sufficient to power the SCS system, it is possible to use the E46ADCN power supply. 0 675 90 F E B A General note: the devices listed in the legend are for the LivingLight series. ITEM E49 LN4650 LN4649 LN4653 LN4652 LN4691 MH201 F430R8 Cooling Heating V3 V2 V1 L N L N Outside the door indicator BUS-SCS H4650 LN4650 Principle and configuration diagram for a hotel room 15/01/2015 3