Preview only show first 10 pages with watermark. For full document please download

H723xc Series & H923 Current Transducers: 0-10vdc Analog Output 5

   EMBED


Share

Transcript

Current Monitoring Current Transducers: 0-10VDC Analog Output H723xC Series & H923 5Year SPECIFICATIONS Sensor Power Insulation Class Frequency Range Temperature Range Humidity Range Accuracy TM Warranty Induced from monitored current 300VAC RMS 50/60 Hz -15° to 60°C (5° to 140°F) 10-90% RH, non-condensing ±2% F.S. from 10% to 100% (selected range) Response Time 2 sec. Terminal Block Wire Size 24-14 AWG (0.2 to 2.1 mm2) Terminal Block Torque Agency Approvals 3.5 to 4.4 in-lbs (0.4 to 0.5 N-m) CE: EN61010-1, CAT III, pollution degree 2, basic insulation H923 EXAMPLE LINEAR OUTPUT Scale software as shown 10V SENSOR OUTPUT H723 0V Selected Range 0A Maximize Reliability Minimize Installed Cost SENSED AMPS Load Trending With 0-10 VDC Output FEATURES DESCRIPTION ● Self-powered analog current transducer 0-10VDC output ● Self-gripping, split-core design for fast retrofit installation...no need to remove conductor (H923) ● No jumpers on unit...reduces installation error ● No external power required for sensor ● Factory calibrated field-selectable ranges for high resolution and installation ease ● One device does the work of three...less to stock ● Removable mounting bracket for installation flexibility ● Bracket on H923 can be installed in three different configurations...added flexibility ● 100% solid state...no moving parts to fail ● 5-year warranty The Hawkeye 723LC, 723HC, and H923 Series provide accurate load trending information with a proportional 0-10VDC output signal. Devices offer three amperage range options, with slide-switch selection for easy field adjustment – no need for jumpers. Shop for Power Metering products online at: www. APPLICATIONS ● Load trending ● Motor control ● Fan/pump status PowerMeterStore.com TM 1.877.766.5412 HQ0001765.D 0115 Current Monitoring H723xC Series & H923 WIRING DIAGRAMS DIMENSIONAL DRAWINGS Monitoring Fan /Pump Motors for Positive Proof of Flow H723LC/H723HC Removable/Adjustable Mounting Bracket CONTACTOR 0.9" (23 mm)  0.7" (19 mm) 3.0" ** (75 mm) CONTROLLER AI COMMON – 0-10VDC + 0.2” x 0.15” slot (2x) 2.8" (68 mm) 1.1" * (27 mm) Fan or Pump 4.2" (106 mm) 3.8" (95 mm) H923 Removable Mounting Bracket 1.0” (25 mm) 1.1” (26 mm) 3.1”** (79 mm) 0.8” (21 mm) Bracket can be mounted on three sides for added installation flexibility. Self-gripping Iris 2.8” (70 mm) 1.4”* (36 mm) Ø 0.3” (8 mm) 2.5” (64 mm) 3.0” (76 mm) * Terminal block may extend up to 1/8” over the height dimensions shown. ** Slide switch may extend up to 1/4” over the height dimensions shown. ORDERING INFORMATION MODEL AMPERAGE RANGE H723LC 0 - 10/20/40A H723HC 0 - 50/100/200A H923 0 - 20/100/150A SENSOR OUTPUT 0 - 10VDC HOUSING CE Solid-core n Solid-core n Split-core n ACCESSORIES DIN Rail Clip Set (AH01) DIN Rail (AV01) and DIN Stop Clip (AV02) AV01 AH01 HQ0001765.D 0115 Shop for Power Metering products online at: www. AV02 PowerMeterStore.com 1.877.766.5412