Preview only show first 10 pages with watermark. For full document please download

Hardieshingle Installation Inst_hz10_1

   EMBED


Share

Transcript

Florida Product Approval HardieSoffit® Panel • For use inside HVHZ: o HardieSoffit Panel fastener types, fastening schedule, and installation shall be in accordance with the Miami-Dade County Florida NOA 15-0122.04. Consult the HardieSoffit product installation instructions on the follow pages for all other installation requirements. • For use outside of HVHZ, o HardieSoffit Panel fastener types, fastening schedule, and installation shall be in accordance with Engineering Evaluation Report RIO-2554-15. Consult the HardieSoffit product installation instructions on the follow pages for all other installation requirements. Siding STRAIGHT EDGE, STAGGERED EDGE, HALF ROUNDS & INDIVIDUAL SHINGLES INSTALLATION REQUIREMENTS - PRIMED & COLORPLUS® PRODUCTS EFFECTIVE SEPTEMBER 2013 Visit www.jameshardie.com for the most recent version. IMPORTANT: FAILURE TO INSTALL AND FINISH THIS PRODUCT IN ACCORDANCE WITH APPLICABLE BUILDING CODES AND JAMES HARDIE WRITTEN APPLICATION INSTRUCTIONS MAY LEAD TO PERSONAL INJURY, AFFECT SYSTEM PERFORMANCE, VIOLATE LOCAL BUILDING CODES, AND VOID THE PRODUCT ONLY WARRANTY. BEFORE INSTALLATION, CONFIRM THAT YOU ARE USING THE CORRECT HARDIEZONE® INSTRUCTIONS. TO DETERMINE WHICH HARDIEZONE APPLIES TO YOUR LOCATION, VISIT WWW.HARDIEZONE.COM OR CALL 1-866-942-7343 (866 9HARDIE) CUTTING INSTRUCTIONS STORAGE & HANDLING: Store flat and keep dry and covered prior to installation. Installing siding wet or saturated may result in shrinkage at butt joints. Carry planks on edge. Protect edges and corners from breakage. James Hardie is not responsible for damage caused by improper storage and handling of the product. OUTDOORS 1. Position cutting station so that wind will blow dust away from user and others in working area. 2. Use one of the following methods: a. Best: i. Shears (manual, electric or pneumatic) b. Better: i. Dust reducing circular saw equipped with a HardieBlade saw blade and HEPA vacuum extraction c. Good: i. Dust reducing circular saw with a HardieBlade saw blade (only use for low to moderate cutting) ® INDOORS 1. Cut only using shears (manual, electric or pneumatic). 2. Position cutting station in well-ventilated area - NEVER use a power saw indoors - NEVER use a circular saw blade that does not carry the HardieBlade saw blade trademark - NEVER dry sweep – Use wet suppression or HEPA Vacuum Important Note: For maximum protection (lowest respirable dust production), James Hardie recommends always using “Best”-level cutting methods where feasible. NIOSH-approved respirators can be used in conjunction with above cutting practices to further reduce dust exposures. Additional exposure information is available at www.jameshardie.com to help you determine the most appropriate cutting method for your job requirements. If concern still exists about exposure levels or you do not comply with the above practices, you should always consult a qualified industrial hygienist or contact James Hardie for further information. SD083105 GENERAL REQUIREMENTS: • HardieShingle® siding can be installed over braced wood or steel studs spaced a maximum of 24" o.c. or directly to minimum 7/16" thick sheathing. See general fastening requirements. • Information on installing James Hardie products over foam can be located in JH Tech Bulletin 19 at www. jamehardie.com • A water-resistive barrier is required in accordance with local building code requirements. The water-resistive barrier must be appropriately installed with penetration and junction flashing in accordance with local building code requirements. James Hardie will assume no responsibility for water infiltration. James Hardie does manufacture HardieWrap Weather Barrier, a non-woven non-perforated housewrap¹, which complies with building code requirements. • When installing James Hardie products all clearance details in figs. 1,2,3,4,5,6 &7 must be followed. • Adjacent finished grade must slope away from the building in accordance with local building codes - typically a minimum of 6" in the first 10'. • Do not install James Hardie products, such that they may remain in contact with standing water. • HardieShingle siding may be installed on vertical wall applications only. • DO NOT use stain, oil/alkyd base paint, or powder coating on James Hardie® Products. ® ® CLEARANCES Install siding and trim products in compliance with local building code requirements for clearance between the bottom edge of the siding and the adjacent finished grade. Maintain a minimum 1" - 2" clearance between James Hardie® products and paths, steps and driveways. Figure 3 Figure 2 Figure 1 siding concrete foundation Maintain a minimum 1" - 2" clearance between James Hardie products and decking material. siding deck material 1" - 2" min. 6" min. joist water resistive barrier At the juncture of the roof and vertical surfaces, flashing and counterflashing shall be installed per the roofing manufacturer’s instructions. Provide a minimum 1" - 2" clearance between the roofing and the bottom edge of the siding and trim. trim Figure 4 1" - 2" min. 1" - 2" min. flashing ledger starter course flashing ¹For additional information on HardieWrap® Weather Barrier, consult James Hardie at 1-866-4Hardie or www.hardiewrap.com WARNING: AVOID BREATHING SILICA DUST James Hardie® products contain respirable crystalline silica, which is known to the State of California to cause cancer and is considered by IARC and NIOSH to be a cause of cancer from some occupational sources. Breathing excessive amounts of respirable silica dust can also cause a disabling and potentially fatal lung disease called silicosis, and has been linked with other diseases. Some studies suggest smoking may increase these risks. During installation or handling: (1) work in outdoor areas with ample ventilation; (2) use fiber cement shears for cutting or, where not feasible, use a HardieBlade® saw blade and dust-reducing circular saw attached to a HEPA vacuum; (3) warn others in the immediate area; (4) wear a properly-fitted, NIOSH-approved dust mask or respirator (e.g. N-95) in accordance with applicable government regulations and manufacturer instructions to further limit respirable silica exposures. During clean-up, use HEPA vacuums or wet cleanup methods - never dry sweep. For further information, refer to our installation instructions and Material Safety Data Sheet available at www.jameshardie.com or by calling 1-800-9HARDIE (1-800-942-7343). FAILURE TO ADHERE TO OUR WARNINGS, MSDS, AND SD050905 INSTALLATION INSTRUCTIONS MAY LEAD TO SERIOUS PERSONAL INJURY OR DEATH. HS11121_P1/5 6/13 KICKOUT FLASHING Figure 7 Maintain a minimum 1" gap between gutter end caps and siding & trim. Maintain a 1/4" clearance between the bottom of James Hardie® products and horizontal flashing. Do not caulk gap. Step flashing Self-adhering membrane Figure 6 Self-adhering eaves membrane Figure 5 siding Do not Caulk Kickout flashing 1/4" gap Drip edge siding fascia gutter and end cap Figure 7, Kickout Flashing To prevent water from dumping behind the siding and the end of the roof intersection, install a "kickout" as required by IRC code R905.2.8.3 : “…flashing shall be a min. of 4” high and 4” wide.” James Hardie recommends the kickout be angled between 100° - 110° to  maximize water deflection TRIM CONSIDERATION: Minimum 1" trim thickness is needed as Panels stack at a depth of roughly 15/16" for the 7" reveal. If additional trim depth is desired, you can place a spacer under the trim (Fig. 8C & 8D). Figure 8B It is best to install a self-adhering membrane on the wall before the subfascia and trim boards are nailed in place, and then come back to install the kickout. Housewrap 1" flashing Figure 8A Because of the volume of water that can pour down a sloped roof, one of the most critical flashing details occurs where a roof intersects a sidewall. The roof must be flashed with step flashing. Where the roof terminates, install a kickout to deflect water away from the siding. Figure 8C BLOCKED PENETRATIONS Penetrations such as hose bibs and holes 1 ½” or larger such as dryer vents should have a block of trim around point of penetration. Figure 8D GABLE INSTALLATION: Installation over sheathing is recommended (Required for Individuals) for gables.* 1) Find the center stud of your of your Gable and snap a caulk line down 2) Measure out 16”* to both the left and the right of the center line and snap a caulk line 3) Measure up 2” if you are off a roof line or ¼” if you are starting above a band board 4) Set the bottom of your 1 ¼” starter strip at that line 5) Place your 8 ¼” Starter Course -bottom level with the bottom of the starter strip 6) Set your first row of Shingle - starting the first piece at the vertical line left of center (If you are using staggered edged shingles Trim down the first row to the shortest shingle length) 7) Drive nails approximately ¼” above Key ways 5 per full panel Center Nail can be either one of the keyways. (Stay by keyway to avoid shiners) (EX1) Blue Dots show nail placement 8) Measure up 7” with straight and 6” with Staggered edge and snap a caulk line to get your proper exposure 9) The second row will start at the center line 10) The Third row will start at the line right of center 11) As you work your way up the gable make sure you Keep your Cut Pieces you will use the pieces on the edges of the gable (EX2) 12) Edges Gable butting into trim leave a 1/8” Gap (for house movement and Caulking) 13) Make sure to sure siding nails on the small pieces on the edges (Do not use a trim nail to install!) Figure 9 Find center of gable; Snap a chalk line Figure 10 Snap chalk line; 16" from center to the left and right 1¼" starter strip Make sure to meet clearances at roof line and/or horizontal trim Figure 11 Snap chalk line 15¼" from bottom of starter course 8¼" starter course in line with starter strip 15.25 Figure 12 Snap chalk line 7" above first row for second row of shingles First shingle goes on far left chalk line Figure 13 Snap chalk line 7" above second row for third row of shingles Second row begins at center chalk line Figure 14 Use left over and new pieces, where necessary, to fill in opposite side Third row begins at right chalk line 7.00 *Panels can also be installed direct to stud up to 24"OC. Note: Snapped chalk lines help guide installation, when installing straight edge panels or Individual shingles use a straight edge on bottom edges if uniform straight edge is desired. HS11121_P2/5 8/13 HARDIESHINGLE® STAGGERED EDGE PANELS INSTALLATION Figure 15 Fastener Requirements 0.083" x 0.187" HD x 1 1/2" long ringshank nails are used for fastening Steps 1- 4 HardieShingle® Staggered Edge Panels to both framing and to 7/16" thick APA rated sheathing. 16" or 24" o.c. 1/8” min. Trim gap for caulk water-resistive barrier sheathing HardieShingle Staggered Edge Panel Installation DO NOT NAIL THROUGH 6" THIS AREA Install HardieShingle® panels with joints butted in moderate contact. Due to 15 7/8" overlapping of the joints, caulk is not required except where panels abut trim panels 3/8" boards. (figs 15 & 17). Ensure keyways do not line up on subsequent courses. 1) Install a 1-1/4" starter strip, then install a 8-1/4" wide HardiePlank® lap siding starter course. 2) Place first panel so that panel end centers over stud. Trim panel as needed. Butt the cut end into trim as shown (figs 15 & 17). When installing over a band board or second any horizontal surface, leave 1/4" gap between bottom of siding and flashing. trim first panel course 3) Secure panel, leaving 1/8" gap for caulk at trim and continue the course to hit center of position nails on nail line and secure into framing. furthest stud along the wall. Only when application is to minimum 7/16" thick APA rated sheathing, position nails on nail line spaced a 4) Start the second course, by removing the equivalent of one full stud maximum of 13 3/4" o.c. Allow 3/8" from panel edges. cavity (16" or 24" OC), again abutting the cut end into the trim (figs 15 & 17). Steps 5 & 6 This is to prevent pattern repetition. Repeat step 3. 1/8” min. gap for caulk 5) Start the third course, by removing the equivalent of two full stud cavities (figs 15 & 17) and repeat step 3. 6) Continue up the wall repeating steps 2 through 6 until desired height is reached. third ® 8 1/4" HardiePlank® lap siding 1¼" starter strip 6" course Note: For aesthetic purposes you may trim the bottom of the panel to create a straight edge. If doing so, ensure all cuts ends are properly sealed and painted (fig 14) second course 6" first course Figure 16 1/4" gap. Do not caulk. band board HARDIESHINGLE® STAGGERED EDGE PANEL COVERAGE Panels for sidewall applications are available in 48" lengths. Pieces needed for one square (100sq.ft.) of product coverage = approximately 50, based on a maximum 6" exposure from the top edge of HardieShingle panels in subsequent courses (refer to Figure 15). 7" EXPOSURE HARDIESHINGLE® STRAIGHT EDGE PANELS INSTALLATION Maximum Exposure of 7" REFER TO STAGGERED EDGE INSTRUCTIONS ABOVE Steps 1 - 4 Trim 1/8” min. gap for caulk 16" or 24" o.c. Figure 16 Steps 5 & 6 water-resistive barrier 1/8” min. gap for caulk sheathing third course 15-1/4" panels DO NOT NAIL THROUGH THIS AREA 7" 15-1/4" panels 3/8" 8¼" trim first panel ® to hit center of HardiePlank furthest stud lap siding position nails on nail line and secure into framing. Only when application is to minimum 7/16" thick APA rated sheathing, position nails on nail line spaced a maximum of 13 3/4" o.c. Allow 3/8" from panel edges. second course 7" second course 7" first course 1¼" starter strip HARDIESHINGLE® STRAIGHT EDGE PANEL COVERAGE Panels for sidewall applications are available in 48" lengths. Pieces needed for one square (100sq.ft.) of product coverage = approximately 43, based on maximum 7" exposure. HS11121_P3/5 6/13 HARDIESHINGLE® INDIVIDUAL SHINGLE INSTALLATION HardieShingle® Individual Shingles must be installed with the widest part of Figure 18 the shingle placed downwards and directly to minimum 7/16" thick Trim 1/8” min. sheathing. gap for Fastener Requirements caulk 0.091" x 0.221" HD x 1 1/2" or 0.121" x 0.371" HD x 1 1/4" long corrosion resistant siding nails are used for fixing HardieShingle siding to 7/16" thick APA rated sheathing. HardieShingle® Individual Shingle Installation Due to overlapping of the joints, caulk is not required except where panels about trim boards. Space shingles a maximum 1/4" apart and leave a 15-1/4" minimum lap of 1 1/2" between successive courses (fig. 19). shingle 1) Install 1 1/4" starter strip and a 8 1/4" wide HardiePlank® siding starter course. 2) Install first shingle from the end abutting trim. Install widest part of shingle placed downwards. (fig. 18). 3) Secure shingle, leaving a 1/8" gap for caulk at trim and continue the course along the wall. 4) Start the second course, leaving a minimum lap of 1 1/2" between successive courses, again from the end abutting the trim. Repeat step 3. 5) Continue up the wall repeating steps 2 through 5 until desired height is reached. HARDIESHINGLE® INDIVIDUAL SHINGLE COVERAGE Individual Shingles for sidewall applications are available in assorted widths as listed below. Bundles needed for one square (100 sq. ft.) of product coverage: Number Pieces Shingle of Bundles per Bundle Width 4-3/16" 3 15 5-1/2" 6 15 6-3/4" 3 15 7-1/4" 6 15 10" 3 15 16" or 24" o.c. water-resistive barrier sheathing 7" postion nails on nail line a minimum 3/8" from edge 8¼" HardiePlank® lap siding 1¼" starter strip Figure 19 space shingles max 1/4” apart 15-1/4" shingle 7" max. exposure ! Leave a min. lap of 1-1/2” between joints in succesive course Install with the widest part of the shingle placed downwards HARDIESHINGLE® HALF-ROUND PANELS INSTALLATION Fastener Requirements 0.083" x 0.187" HD x 1 1/2" long ringshank nails are used for fastening HardieShingle® Half-Round Panels to both framing and to 7/16" thick APA rated sheathing. Figure 20 HardieShingle Half-Round Panel Installation water-resistive trim board 16" or 24" barrier* Install HardieShingle® panels with joints butted in moderate contact. Due to o.c. overlapping of the joints, caulk is not required except where panels abutt 1/8 gap for sheathing trim boards. (fig. 20). Ensure keyways do not line up on subsequent courses. caulk ® 1) Install a 1-1/4" starter strip, then install a 8-1/4" wide HardiePlank lap siding starter course. 7" 2) Place first panel so that panel end centers over stud. Trim panel as 15 1/4" shingles 1" needed. Butt the cut end into trim as shown (figs 20). When installing over a band board or any horizontal surface, leave 1/4" gap between 3/8" bottom of siding and flashing. 3) Secure panel, leaving 1/8" gap for caulk at trim and continue the course along the wall. 4) Start the second course, by removing the equivalent of one full stud cavity (16" or 24" OC), again abutting the cut end into the trim (fig 20). This is to correct prevent pattern repetition. Repeat step 3. trim first panel 1 1/4" position nails into framing alignment 5) Start the third course, by removing the equivalent of two full stud cavities to hit furthest stud starter strip through previous courses. Only when application is to (figs 15 & 17) and repeat step 3. minimum 7/16" thick APA 6) Continue up the wall repeating steps 2 through 6 until desired height is reached. rated sheathing, position nails 8-1/4" HardiePlank ® HARDIESHINGLE HALF-ROUND PANEL COVERAGE spaced a maximum 13 3/4" o.c. Allow 3/8" from panel edges lap siding Panels for sidewall applications are available in 48" lengths. Pieces needed for one square (100 sq. ft.) of product coverage=43 pieces with 7" exposure. HS11121_P4/5 6/13 CORNER DETAILS Figure 21 A. Panels butted against corner boards. B. Panels butted against square wood strip on inside corner, flashing behind. C. Laced outside corner. D. Laced inside corner. minimum (1") thick trim WINDOWS AND DOORS Building wall components such as windows, doors and other exterior wall penetrations shall be installed in accordance with the component manufacturer’s written installation instructions and local building codes. Where windows or doors are installed, continue the application of siding as if the wall is complete. Triming for the opening and using the resulting piece may throw off the spacing above the break. PNEUMATIC FASTENING GENERAL FASTENING REQUIREMENTS Fasteners must be corrosion resistant, galvanized, or stainless steel. Electro-galvanized are acceptable but may exhibit premature corrosion. James Hardie recommends the use of quality, hot-dipped galvanized nails. James Hardie is not responsible for the corrosion resistance of fasteners. Stainless steel fasteners are recommended when installing James Hardie® products near the ocean, large bodies of water, or in very humid climates. • Consult applicable code compliance report for correct fasteners type and placement to achieve specified design wind loads. • NOTE: Published wind loads may not be applicable to all areas where Local Building Codes have specific jurisdiction. Consult James Hardie Technical Services if you are unsure of applicable compliance documentation. • Drive fasteners perpendicular to siding and framing. • Fastener heads should fit snug against siding (no air space). (fig. A ) • Do not over-drive nail heads or drive nails at an angle. • If nail is countersunk, fill nail hole and add a nail. (fig. B) • For wood framing, under driven nails should be hit flush to the plank with a hammer (For steel framing, remove and replace nail). • Do not use aluminum fasteners, staples, or clipped head nails. snug flush Figure A countersunk, fill & add nail Figure B DO NOT DO NOT under drive nails staple James Hardie products can be hand nailed or fastened with a pneumatic tool. Pneumatic fastening is highly recommended. Set air pressure so that the fastener is driven snug with the surface of the siding. A flush mount attachment on the pneumatic tool is recommended. This will help control the depth the nail is driven. If setting the nail depth proves difficult, choose a setting that under drives the nail. (Drive under driven nails snug with a smooth faced hammer - Does not apply for installation to steel framing). CUT EDGE TREATMENT Caulk, paint or prime all field cut edges. James Hardie touch-up kits are required to touch-up ColorPlus products. CAULKING For best results use an Elastomeric Joint Sealant complying with ASTM C920 Grade NS, Class 25 or higher or a Latex Joint Sealant complying with ASTM C834. Caulking/Sealant must be applied in accordance with the caulking/sealant manufacturer’s written instructions. Note: OSI Quad as well as some other caulking manufactuers DO NOT allow tooling. PRIMING & PAINTING DO NOT use stain, oil/alkyd base paint, or powder coating on James Hardie® Products. James Hardie® products must be painted within 180 days for primed product and 90 days for unprimed. In addition non ColorPlus® product versions of HardieShingle® Siding require a field applied prime coat. 100% acrylic primers and topcoats are recommended. Do not paint when wet. For application rates refer to paint manufacturers specifications. Back rolling is recommended when paint is spray applied. COLORPLUS® TECHNOLOGY CAULKING, TOUCH-UP & LAMINATE • Care should be taken when handling and cutting James Hardie ColorPlus products. During installation use a wet soft cloth or soft brush to gently wipe off any residue or construction dust left on the product, then rinse with a garden hose. • Touch up nicks, scrapes and nail heads using the ColorPlus® Technology touch up applicator. Touch-up should be used sparingly. If large areas require touch-up, replace the damaged area with new HardieShingle® siding with ColorPlus Technology. • Laminate sheet must be removed immediately after installation of each course. • Terminate non-factory cut edges into trim where possible, and caulk. Color matched caulks are available from your ColorPlus® product dealer. • Treat all other non-factory cut edges using the ColorPlus Technology edge coaters, available from your ColorPlus product dealer. Note: James Hardie does not warrant the usage of third party touch-up or paints used as touch-up on James Hardie ColorPlus products. Problems with appearance or performance arising from use of third party touch-up paints or paints used as touch-up that are not James Hardie touch-up, will not be covered under the James Hardie ColorPlus Limited Finish Warranty. PAINTING JAMES HARDIE® SIDING AND TRIM PRODUCTS WITH COLORPLUS® TECHNOLOGY When repainting ColorPlus products, James Hardie recommends the following regarding surface preparation and topcoat application: • Ensure the surface is clean, dry, and free of any dust, dirt, or mildew • Repriming is normally not necessary • 100% acrylic topcoats are recommended • DO NOT use stain, oil/alkyd base paint, or powder coating on James Hardie® Products. • Apply finish coat in accordance with paint manufacturers written instructions regarding coverage, application methods, and application temperature • DO NOT caulk nail heads when using ColorPlus products, refer to the ColorPlus touch-up section RECOGNITION: In accordance with ICC-ES Evaluation Report ESR-2290, HardieShingle lap siding is recognized as a suitable alternate to that specified in: the 2006,2009,&2012 International Residential Code for One- and Two-Family Dwellings, and the 2006, 2009, & 2012 International Building Code,. HardieShingle lap siding is also recognized for application in the following: City of Los Angeles Research Report No. 24862, State of Florida listing FL#889, Dade County, Florida NOA No. 02-0729.02, U.S. Dept. of HUD Materials Release 1263c, Texas Department of Insurance Product Evaluation EC-23, City of New York MEA 223-93-M, and California DSA PA-019. These documents should also be consulted for additional information concerning the suitability of this product for specific applications © 2013 James Hardie Building Products, Inc. All rights reserved. TM, SM, and ® denote trademarks or registered trademarks of James Hardie Technology Limited. is a registered trademark of James Hardie Technology Limited. Please visit www.jameshardie.com for Additional Product Information and Availability, Installation Information, Warnings, and Warranties HS11121_P5/5 6/13