Transcript
HC0150B03 Hybrid Coupler 3 dB, 90 o Rev B0
Description The HC0150B03 is a low profile, high performance 3dB hybrid coupler in a new easy to use,manufacturing friendly surface mount package. The HC0150B03 is designed particularly for balanced power and low noise amplifiers, plus signal distribution and other applications where low insertion loss and tight amplitude and phase balance is required. It can be used in high power applications up to 125 Watts.
Orientation Marker Part No.
Parts have been subjected to rigorous qualification testing and they are manufactured using materials with coefficients of thermal expansion (CTE) compatible with common substrates such as FR4, G-10, RF-35, RO4350 and polyimide.
GND
Electrical Specifications
Features: ● 130 –174 MHz ● Very Low Loss ● Tight Amplitude Balance ● High Isolation ● Low VSWR ● Good Repeatability ● CTE compatible with FR4, G-10, RF-35, RO4350B and polyimide ● Immersion gold, prevent surface oxidation & scratch ● RoHS Compliant ● Tape & Reel Package available
Frequency
Isolation
Insertion Loss
VSWR
Amplitude Balance
MHz
dB Min
dB Max
Max : 1
dB Max
130- 174
22
0.40
1.13
± 0.25
Phase Balance
Power
Operating Temp.
Degrees
Avg. CW Watts
ºC
90 ± 3.5
125
-55 to +95
Notes: 1. All the above data are based on specified demo board. 2. Insertion loss:Thru board loss has been removed. Mechanical Outline
TOP VIEW Pin 1
SIDE VIEW Pin 2
BOTTOM VIEW Pin 2
Pin 1
YANTEL HC0150B03 XXXX Pin 4
Pin 3
Pin 3
Yantel Corporation Add Floor 2, Building 2, Gaofa Technology Park, Longjing, Nanshan, Shenzhen, China Tel 86-755-8355-1886 Fax 86-755-8355-2533 For detailed performance specs & shopping online see Yantel web site : www.yantel-corp.com
Pin 4
HC0150B03 Hybrid Coupler 3 dB, 90 o Rev B0
Hybrid Coupler Pin Configuration The HC0150B03 has an orientation marker to denote Pin 1. Once port one has been identified the other ports are known automatically. Please see the chart below for clarification:
Configuration Splitter Splitter Splitter Splitter
Pin 1 Input Isolated
Pin 2 Isolated Input
-3dB Ð - 90 -3dB Ð
-3dB Ð -3dB Ð - 90
*Combiner *Combiner *Combiner *Combiner
A Ð - 90 AÐ Isolated Output
Pin 3 -3dB Ð - 90 -3dB Ð Input Isolated
Pin 4 -3dB Ð -3dB Ð - 90 Isolated Input
Isolated Output
Output Isolated
AÐ
A Ð - 90 Output Isolated
A Ð - 90 AÐ
AÐ
A Ð - 90
*Note: “A” is the amplitude of the applied signals. When two quadrature signals with equal amplitudes are applied to the coupler as described in the table, they will combine at the output port. If the amplitudes are not equal, some of the applied energy will be directed to the isolated port. Typical Performance Data (@25℃) Frequency (MHz)
Coupling (dB)
Transmission (dB)
130 132.25 134.5 136.75 139 141.25 143.5 145.75 148 150.25 152.5 154.75 157 159.25 161.5 163.75 166 168.25 170.5 172.75 175
-3.35 -3.33 -3.30 -3.29 -3.28 -3.27 -3.27 -3.26 -3.26 -3.25 -3.26 -3.27 -3.27 -3.28 -3.29 -3.30 -3.31 -3.34 -3.36 -3.39 -3.41
-3.19 -3.21 -3.23 -3.25 -3.27 -3.29 -3.31 -3.31 -3.33 -3.34 -3.34 -3.34 -3.35 -3.35 -3.34 -3.33 -3.33 -3.31 -3.30 -3.30 -3.28
Insertion Loss (dB) -0.26 -0.26 -0.25 -0.26 -0.26 -0.27 -0.28 -0.27 -0.28 -0.28 -0.29 -0.29 -0.30 -0.30 -0.30 -0.30 -0.31 -0.31 -0.32 -0.33 -0.33
Isolation (dB) -23.72 -23.76 -23.82 -23.88 -23.94 -23.99 -24.04 -24.10 -24.15 -24.21 -24.28 -24.35 -24.40 -24.46 -24.53 -24.60 -24.66 -24.72 -24.80 -24.87 -24.95
Amplitude Balance (dB) -0.16 -0.12 -0.07 -0.04 -0.01 0.02 0.04 0.05 0.07 0.09 0.08 0.07 0.08 0.07 0.05 0.03 0.02 -0.03 -0.06 -0.09 -0.13
Phase (degree) -91.08 -91.09 -91.17 -91.27 -91.31 -91.35 -91.45 -91.52 -91.57 -91.70 -91.70 -91.81 -91.94 -92.05 -92.12 -92.20 -92.25 -92.26 -92.42 -92.46 -92.56
Return Loss(dB) S11 -26.60 -26.75 -26.91 -27.04 -27.15 -27.27 -27.39 -27.51 -27.64 -27.76 -27.84 -27.92 -28.00 -28.08 -28.16 -28.24 -28.30 -28.34 -28.39 -28.43 -28.47
S22 -27.96 -28.08 -28.20 -28.27 -28.32 -28.38 -28.45 -28.50 -28.57 -28.63 -28.71 -28.75 -28.79 -28.80 -28.78 -28.74 -28.73 -28.77 -28.78 -28.77 -28.77
S33 -26.55 -26.71 -26.85 -26.98 -27.12 -27.26 -27.37 -27.49 -27.62 -27.76 -27.85 -27.88 -27.95 -28.01 -28.07 -28.14 -28.17 -28.22 -28.24 -28.25 -28.23
Yantel Corporation Add Floor 2, Building 2, Gaofa Technology Park, Longjing, Nanshan, Shenzhen, China Tel 86-755-8355-1886 Fax 86-755-8355-2533 For detailed performance specs & shopping online see Yantel web site : www.yantel-corp.com
S44 -26.43 -26.62 -26.83 -27.00 -27.17 -27.33 -27.50 -27.67 -27.84 -28.00 -28.11 -28.21 -28.30 -28.40 -28.50 -28.60 -28.67 -28.67 -28.67 -28.67 -28.67
HC0150B03 Hybrid Coupler 3 dB, 90 o Rev B0
Typical Performance (-55°C, 25°C, 95°C,125°C: 130-175 MHz)
Return Loss (Port 1)
Return Loss (Port 2)
0.00
0.00 -55℃
-5.00
25℃
-10.00
25℃
-10.00
95℃
-15.00
-55℃
-5.00
95℃
-15.00
125℃
-20.00
-20.00
-25.00
-25.00
-30.00
-30.00
-35.00
125℃
-35.00 130
139
148
157
166
175
130
139
148
157
Frequency (MHz)
Frequency (MHz)
Return Loss (Port 3)
Return Loss (Port 4)
0.00
166
175
0.00 -55℃
-5.00
-55℃
-5.00
25℃ -10.00
125℃
-15.00
-20.00
-25.00
-25.00
-30.00
-30.00
-35.00
-35.00 139
148
157
166
95℃
-15.00
-20.00
130
25℃
-10.00
95℃
175
125℃
130
Frequency (MHz)
139
148
157
Frequency (MHz)
Yantel Corporation Add Floor 2, Building 2, Gaofa Technology Park, Longjing, Nanshan, Shenzhen, China Tel 86-755-8355-1886 Fax 86-755-8355-2533 For detailed performance specs & shopping online see Yantel web site : www.yantel-corp.com
166
175
HC0150B03 Hybrid Coupler 3 dB, 90 o Rev B0
Typical Performance (-55°C, 25°C, 95°C,125°C: 130-175 MHz)
Coupling & Transmission (Port 1 feeding) -2
Insertion Loss(Port 1 feeding) 0.00
-55℃
-2.2
25℃
Coupling
-2.4
95℃ 125℃
-2.6
95℃ 125℃
25℃
Transmission
25℃
-0.20
-55℃
-2.8
-55℃
-0.10
-0.30
95℃
-3
125℃
-0.40
-3.2 -0.50
-3.4 -3.6
-0.60 130
139
148
157
166
175
130
139
148
157
Frequency (MHz)
Frequency (MHz)
Phase (Port 1 feeding)
Isolation (Port 1 feeding)
-85.00
166
175
0.00 -55℃
-87.00
-55℃
-5.00
25℃
25℃
95℃
-10.00
95℃
-89.00
125℃
125℃
-15.00
-91.00 -20.00 -93.00
-25.00
-95.00
-30.00 130
139
148
157
166
175
130
Frequency (MHz)
139
148
157
Frequency (MHz)
Yantel Corporation Add Floor 2, Building 2, Gaofa Technology Park, Longjing, Nanshan, Shenzhen, China Tel 86-755-8355-1886 Fax 86-755-8355-2533 For detailed performance specs & shopping online see Yantel web site : www.yantel-corp.com
166
175
HC0150B03 Hybrid Coupler 3 dB, 90 o Rev B0
Definition of Measured Specifications Parameter
Definition
VSWR (Voltage Standing Wave Ratio)
The impedance match of the coupler to a 50W system. A VSWR of 1:1 is optimal. The impedance match of the coupler to a 50W system. Return Loss is an alternate means to express VSWR. The input power divided by the sum of the power at the two output ports. The input power divided by the power at the isolated port. The difference in phase angle between the two output ports.
Return Loss
Insertion Loss
Isolation
Phase Balance
Amplitude Balance
The power at each output divided by the average power of the two outputs.
Mathematical Representation VSWR =
Vmax Vmin
Vmax = voltage maxima of a standing wave Vmin = voltage minima of a standing wave
Return Loss (dB)= 20log
VSWR + 1 VSWR - 1
Insertion Loss(dB)= 10log
Pin Pcpl + Ptransmission
Isolation(dB)= 10log
Pin Piso
Phase at coupled port – Phase at transmisson port
10log
(
Pcpl and 10log Pcpl + Ptransmission 2
)
Test Method 1. Calibrating your vector network analyzer. 2. Connect the VNA 4 Port to DUT respectively. 3. Measure the data of coupling through port 1 to port 4(S41). 4. Measure the data of transmission through port 1 to port 3(S31). 5. Measure the data of isolation through port 1 to port 2(S21). 6. Measure the data of phase port 4 & port 3(port 1 feeding). 7. Measure the data of return loss port 1, port 2, port 3 & port 4. 8. According to the above data to calculate insertion loss, amplitude balance & phase.
(
Ptransmission Pcpl + Ptransmission 2
)
Vector Network Analyzer Port 1 Port 2
Note: 1. When calculating insertion loss at room temperature, demo board loss should be removed from both coupling & transmission data. Please refer to the below table for demo board loss :
Frequency Range(MHz) 100-400 470-860 800-1000 1200-1700 1700-2000 2000-2300 2300-2700
Demo Board Loss (dB) @25℃ 0.02 0.07 0.10
DUT
0.15 0.15 0.20 0.25
Yantel Corporation Add Floor 2, Building 2, Gaofa Technology Park, Longjing, Nanshan, Shenzhen, China Tel 86-755-8355-1886 Fax 86-755-8355-2533 For detailed performance specs & shopping online see Yantel web site : www.yantel-corp.com
Port 3 Port 4
HC0150B03 Hybrid Coupler 3 dB, 90 o Rev B0
Recommended PCB Layout
VIA
Ω
Ground NOTES:
1. 50Ω line width is shown above designing from RO4350B dieletric thickness 0.762mm; copper 1 OZ 2. Bottom side of the PCB is continuous ground plane. 3. All dimensions shown in mm.
Reflow Profile
Peak temperature 235-255 melting point alloy 217-219
Reflow Zone 50-90sec Soaking Zone 60-90sec
cooldown
Preheat/soak 60-80sec
Time(s)
Yantel Corporation Add Floor 2, Building 2, Gaofa Technology Park, Longjing, Nanshan, Shenzhen, China Tel 86-755-8355-1886 Fax 86-755-8355-2533 For detailed performance specs & shopping online see Yantel web site : www.yantel-corp.com
HC0150B03 Hybrid Coupler 3 dB, 90 o Rev B0
Reliability Test Flow Reliability Test
Mechanical/Visual Inspection n=50
Electrical Testing at room temperature S-parameter n=50
Mount parts to test boards n=25
Visual Inspection n=25
Visual Inspection n=25
Resistance to Solder per Mil202F.210E.Condition K heat n=20
Mount boards to Al blocks n=25
Visual Inspection n=25
Electrical Testing at room temperature and over temperature S-parameter(-55℃,25℃,95℃,150℃,200℃) n=25
Electrical Testing at room temperature S-parameter n=25
Control Units n=5
Mechanical/visual Inspection n=25
Visual Inspection n=25
Control Units n=5
Control Units n=5
Voltage Breakdown Test per Mil202F-301 25℃,1KV n=40
Visual Inspection n=50
Electrical Testing at room temperature S-parameter
Control Units n=10
n=50
Thermal Cycle 75 cycles,--55℃ to125℃,5℃/min 15 min dwell n=40
Visual Inspection n=50
Yantel Corporation Add Floor 2, Building 2, Gaofa Technology Park, Longjing, Nanshan, Shenzhen, China Tel 86-755-8355-1886 Fax 86-755-8355-2533 For detailed performance specs & shopping online see Yantel web site : www.yantel-corp.com
HC0150B03 Hybrid Coupler 3 dB, 90 o Rev B0
Reliability Test Flow
Visual Inspection n=50
Electrical Testing at room temperature S-parameter n=50
Control Units n=10
Moisture Resistance Testing -25℃ to 65℃ for 2hrs.@90% humidity.Increase to 95% humidity and soak for 4hrs.ramp temp to 25℃ in 2hrs,repeat for 10 cycles and then soak -10℃ for 3hrs n=40
Electrical Testing at room temperature S-parameter n=50
Visual Inspection n=50
Control Units n=10
Bake parts for 1 hr at 100℃ n=40
Electrical Testing at room temperature S-parameter n=50
High Power Test n=2
Life Testing Rated power input 100℃ base plate temperature 96 hrs 3 in series n=6
Visual Inspection n=50
Electrical Testing at room temperature S-parameter n=6
Visual Inspection n=25
Mechanical Inspection n=25
Microsection 3 Test units and 1 control
Microsection 2 life,1 high power and 1 control
Yantel Corporation Add Floor 2, Building 2, Gaofa Technology Park, Longjing, Nanshan, Shenzhen, China Tel 86-755-8355-1886 Fax 86-755-8355-2533 For detailed performance specs & shopping online see Yantel web site : www.yantel-corp.com
HC0150B03 Hybrid Coupler 3 dB, 90 o Rev B0
Tape and Reel Drawing
Notice:
Feeding Direction
B
E
A.10 Sprocket hole pitch cumulative tolerance is 0.2mm. B. Carrier camber shall be not more than 1mm
F
per 100mm through a length of 250mm. C. All dimensions meet EIA-418-B requirement D. A0 & B0 measured as indicated. E. K0 measured from a place on the inside A
A
SECTION
D1
bottom of the pocket to top surface of carrier
A-A
B
SECTION
B-B
F. Material: PE 100 G. Thickness: 0.40±0.05mm
ITEM
W A0 B0 K0 P
F
E
D D1 P0 P2 T
DIM(mm) 44.00 13.2 25.90 3.60 16.0020.20 1.75 1.50 1.50 4.00 2.00 0.40 TOLE
+0.30 +0.10 +0.10 +0.10 +0.10 +0.10 -0.30 -0.10 -0.10 -0.10 -0.10 -0.10
+0.10 +0.10 -0.10 -0.00
H. 850 units (maximum) / T&R
13" M/R
P/R
+0.10 +0.10 +0.15 +0.05 18.4M/R 1100pcs -0.00 -0.10 -0.15 -0.05
W E F A
Symbol
Dimensions(mm)
W
44.5±0.4
A
330±0.5
T
100±0.3 1.8±0.2
N E
N
F DETAIL2:1
D T
Yantel Corporation Add Floor 2, Building 2, Gaofa Technology Park, Longjing, Nanshan, Shenzhen, China Tel 86-755-8355-1886 Fax 86-755-8355-2533 For detailed performance specs & shopping online see Yantel web site : www.yantel-corp.com
2.1±0.3 10.75±0.3 13.5+0.5/-0.2