Hcmi Room Planning

   EMBED


Share

Transcript

8' CONTRACTOR SHOULD CALL HCMI BEFORE CONSTRUCTION OR ASAP! PHONE: 800-641-4107 FAX: 417-864-7394 10" 8' 12' 1" x 6" x 3ft.mounted to wall 92" AFF to bottom of board. For new construction,use 2 x 6 wall. 7' 8" HF Power Cabinet circuit breaker per HCMI electrical requirements spec sheets. Interconnect between circuit breaker and power cabinet must be made by electrical contractor at time of equipment installation via flexible conduit. Circuit breaker should be mounted flush to the wall. Location of the circuit breaker must meet local, state and federal codes and regulations. Refer to electrical spec sheet for wire size and circuit breaker size. Refer to State approved radiation protection requirements for lead and drywall specification. Lighting on dimmer switch is recommended in room and control booth area. All construction (mechanical, electrical and plumbing) must meet local, state and federal codes and regualtions. HF-300 ELECTRICAL SPECIFICATIONS WIRE SIZE LENGTH TO ROOM DISCONNECT (AWG) HF 300 Power Cabinet LINE VOLTAGE 110 volt outlet 240 VAC, 100 amp circuit breaker Dedicated line. See Barrier Wall Elevation drawing for more detail 50FT 100FT 150FT 200FT 208 1 00 000 220 1 0 00 0000 240 2 1 00 000 250 2 1 0 00 DISCONNECT TO GENERATOR 15FT MAXIMUM 1" x 6" mounted to wall 82" AFF to bottom of board. Board should run from Barrier wall to Buckystand wall. Board must be flat and level. Horizontal pull is 150 lbs. BUCKYSTAND 250MCM 4AWG CONTRACTOR SHOULD CALL HCMI BEFORE CONSTRUCTION OR ASAP! PHONE: 800-641-4107 FAX: 417-864-7394 1" x 6" x 3ft.mounted to wall 92" AFF to bottom of board. For new construction,use 2 x 6 wall. 1" x 6" mounted to wall 82" AFF to bottom of board. Board should run from Barrier wall to Buckystand wall. Board must be flat and level. Horizontal pull is 150 lbs. 10' HF Power Cabinet circuit breaker per HCMI electrical requirements spec sheets. Interconnect between circuit breaker and power cabinet must be made by electrical contractor at time of equipment installation via flexible conduit. Circuit breaker should be mounted flush to the wall. Location of the circuit breaker must meet local, state and federal codes and regulations. Refer to electrical spec sheet for wire size and circuit breaker size. Refer to State approved radiation protection requirements for lead and drywall specification. Lighting on dimmer switch is recommended in room and control booth area. All construction (mechanical, electrical and plumbing) must meet local, state and federal codes and regualtions. ADDITIONAL NOTES: 110 VAC outlet needs to be located near digital detector for power supply. 110 VAC outlet and network jack should be located in control booth for coputer station. 110 VAC outlet and network jack should also be supplied in the location of additional workstations. Consult with doctor to determine these locations. HF-300 ELECTRICAL SPECIFICATIONS 12" x 16" Lead Glass LINE VOLTAGE 50FT 100FT 150FT 208 1 00 000 220 1 0 00 0000 240 2 1 00 000 250 2 1 0 00 HF 300 Power Cabinet 4' 240 VAC, 100 amp circuit breaker Dedicated line. See Barrier Wall Elevation drawing for more detail 110 V outlet Network Jack WIRE SIZE LENGTH TO ROOM DISCONNECT (AWG) DO NOT SCALE 8' 200FT DISCONNECT TO GENERATOR 15FT MAXIMUM 14' 250MCM 4AWG