Preview only show first 10 pages with watermark. For full document please download

Hd Face Mount Hangers Masonry Installation

   EMBED


Share

Transcript

Technical Bulletin HD FACE MOUNT HANGERS MASONRY INSTALLATION The HD series facemount hangers can be used to connect roof framing members, trusses, and floor joists to masonry walls. Allowable loads are based on extensive testing and rely on proper use of Powers® fasteners installed per manufacturer’s specification. • Masonry screws shall be 3/16" diameter Powers® Fasteners Tapper+. • Minimum masonry screw embedment shall be 1-1/4". 2" min 8" min 2" min 8" min Field installation Edge installation (flush to edge only) Fastener Schedule2 Dimensions (in) USP Stock No. HD26 HD28 HD210 HD212 HD26-2 HD28-2 HD210-2 HD212-2 HD44 HD46 HD48 HD410 HD412 HD26-3 HD28-3 HD210-3 HD212-3 HD5210 HD5212 HD66 HD68 HD610 HD612 Steel Gauge 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 Masonry W H 1-9/16 3-1/2 1-9/16 5-1/4 1-9/16 7-3/16 1-9/16 9-13/16 3-1/8 5-1/4 3-1/8 7-1/8 3-1/8 9 3-1/8 11 3-9/16 3-5/16 3-9/16 5-1/16 3-9/16 6-15/16 3-9/16 8-13/16 3-9/16 10-13/16 4-5/8 4-1/2 4-5/8 6-3/8 4-5/8 8-1/4 4-5/8 10-1/4 5-3/8 7-7/8 5-3/8 9-7/8 5-1/2 4-1/16 5-1/2 5-15/16 5-1/2 7-13/16 5-1/2 9-13/16 D 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 Top installation (flush to top only) Qty 4 8 14 20 12 14 20 24 4 12 14 20 24 12 14 20 24 20 24 12 14 20 24 Type 3/16" Tapper+ 3/16" Tapper+ 3/16" Tapper+ 3/16" Tapper+ 3/16" Tapper+ 3/16" Tapper+ 3/16" Tapper+ 3/16" Tapper+ 3/16" Tapper+ 3/16" Tapper+ 3/16" Tapper+ 3/16" Tapper+ 3/16" Tapper+ 3/16" Tapper+ 3/16" Tapper+ 3/16" Tapper+ 3/16" Tapper+ 3/16" Tapper+ 3/16" Tapper+ 3/16" Tapper+ 3/16" Tapper+ 3/16" Tapper+ 3/16" Tapper+ DF/SP Allowable Load (Lbs.)1,4,5,6,7 Joist/Beam Qty 4 6 6 10 6 6 10 12 2 6 6 10 12 6 6 10 12 10 12 6 6 10 12 Corner installation (flush to edge and top) Download (100%) 3 Type 10d x 1-1/2 10d x 1-1/2 10d x 1-1/2 10d x 1-1/2 10d 10d 10d 10d 10d 10d 10d 10d 10d 10d 10d 10d 10d 10d 10d 10d 10d 10d 10d Field 1000 2000 3110 3640 3000 3500 5000 5750 1000 3000 3500 5000 5750 3000 3500 5000 5750 5000 5750 2350 3500 5000 5750 Edge 495 990 1545 1805 1490 1735 2480 2850 495 1490 1735 2480 2850 1490 1735 2480 2850 2480 2850 1165 1735 2480 2850 Top 670 1340 2085 2440 2015 2350 3355 3860 670 2015 2350 3355 3860 2015 2350 3355 3860 3355 3860 1575 2350 3355 3860 Uplift (160%) Corner 335 665 1035 1210 1000 1165 1665 1915 335 1000 1165 1665 1915 1000 1165 1665 1915 1665 1915 780 1165 1665 1915 Field 145 595 595 595 1170 1170 1950 2340 145 1170 1170 1950 2340 1170 1170 1950 2340 2305 2765 1380 1380 2305 2765 Edge 70 295 295 295 580 580 645 645 70 580 580 645 645 580 580 645 645 645 645 645 645 645 645 Top 145 595 595 595 850 850 850 850 145 850 850 850 850 850 850 850 850 850 850 850 850 850 850 Corner 45 195 195 195 380 380 420 420 45 380 380 420 420 380 380 420 420 420 420 420 420 420 420 1) Allowable loads assume the use of Powers® Fasteners 3/16" Tapper+™ with minimum embedment of 1-1/4" into fully grouted wall. 2) Fasteners to be installed per manufacturer's recommendations. 3) 10d x 1-1/2" nails are 0.148" dia. x 1-1/2 long, 10d nails are 0.148 dia. x 3" long. 4) Field installation indicates that the uppermost and outermost fasteners are a minimum of 8" from the top and side of the masonry wall. 5) Edge installation indicates that the hanger is installed flush with the edge of the masonry wall. 6) Top installation indicates that the hanger is installed with the hanger flush with the top of the wall. 7) Corner installation indicates that the hanger is installed in the corner of the masonry wall flush to the edge, and the top fastener is less than 2" from the top. Customer Service & Technical Assistance Phone: 1-800-328-5934 • Fax: 1-952-898-8605 • Email: [email protected] September 2017 uspconnectors.com #USP2485