Hdcs®

   EMBED


Share

Transcript

HDCS Copper Solution ® Pegasus PRECONNECT® Copper Cable TM Application PegasusTM PRECONNECT® copper cable quickly deploys as a permanent link between the distribution area and equipment area in the data center room. Features • Quick and easy installation, saving on-site labor cost • Guaranteed high reliability based on 100% quality inspection in factory • Cat.5e, Cat.6, Cat.6a and Unshielded or shielded options • CM, CMR, CMP and LSZH series fire retardant PRECONNECT® copper cable options • Each copper permanent link performance far exceeds standard TIA/568C and ISO11801, most notably for short link performance Technical Parameters • Complies with relative international standards: TIA 568C / TIA942 ISO11801/ EN50173-5 • Storage temperature: -40°C to 70°C • Operation temperature: -20°C to 60°C HDCS® DATA CENTER Ordering Information Ordering Number Products Description CPB6-121-2-XXX PegasusTM 8Port Cat.6 UTP Box type Preconnect Copper Cable, CM CPB6-123-2-XXX PegasusTM 8Port Cat.6 UTP Box type Preconnect Copper Cable, LSZH CPB6-121-3-XXX PegasusTM 6Port Cat.6 UTP Preconnect Copper Cable, CM CPB6-123-3-XXX PegasusTM 6Port Cat.6 UTP Preconnect Copper Cable, LSZH CPB6-221-2-XXX PegasusTM 8Port Cat.6 FTP Box type Preconnect Copper Cable, CM CPB6-223-2-XXX PegasusTM 8Port Cat.6 FTP Box type Preconnect Copper Cable, LSZH CPB6-221-3-XXX PegasusTM 6Port Cat.6 FTP Preconnect Copper Cable, CM CPB6-223-3-XXX PegasusTM 6Port Cat.6 FTP Preconnect Copper Cable, LSZH CPB6-131-2-XXX PegasusTM 8Port Cat.6 UTP Box type Preconnect Copper Cable, CM CPB6-133-2-XXX PegasusTM 8Port Cat.6 UTP Box type Preconnect Copper Cable, LSZH CPB6-131-3-XXX PegasusTM 6Port Cat.6 UTP Preconnect Copper Cable, CM CPB6-133-3-XXX PegasusTM 6Port Cat.6 UTP Preconnect Copper Cable, LSZH CPB6-231-2-XXX PegasusTM 8Port Cat.6 FTP Box type Preconnect Copper Cable, CM CPB6-233-2-XXX PegasusTM 8Port Cat.6 FTP Box type Preconnect Copper Cable, LSZH CPB6-231-3-XXX PegasusTM 6Port Cat.6 FTP Preconnect Copper Cable, CM CPB6-233-3-XXX PegasusTM 6Port Cat.6 FTP Preconnect Copper Cable, LSZH HDCS® DATA CENTER Pegasus Cat.6 Modular Panel TM Application PegasusTM Cat.6 modular panel is generally applied to make connections with copper LAN cables at each distribution area in the data center room. Features • Each port has a spring dust cover, which provides excellent dust protection • Four sets of colored labels attached for convenient cable management • Panel with longer back cable management for rear cable tidiness and controlling the cable bending radius. • Tool-less keystone jack in panel able to support excellent short link performance • Tool-less termination due to an innovative hinged pressing cover, supports labor saving cable termination Technical Parameters • Complies with standards: TIA568C / TIA 942 ISO11801 / EN50173-5 • • • • Plug insertion life: 750 cycles min. Plug retention force: 30 lbs min. IDC contactor: Accepts 22-26 AWG solid wires Temperature range: -40°C to 70°C High Frequency Performance at 20°C Frequency (MHz) Attenuation (dB/100m) NEXT (dB) RL (dB) PSNEXT (dB) ELFEXT (dB) PSELFEXT (dB) Max. Min. Min. Min. Min. Min. 1.0 0.1 75.0 30.0 73.0 83.1 80.1 4.0 0.1 75.0 30.0 72.3 71.1 68.1 8.0 0.1 75.0 30.0 71.0 66.1 65.4 10.0 0.1 74.0 30.0 70.0 63.1 60.1 16.0 0.1 69.9 30.0 65.9 59.0 56.0 20.0 0.1 68.0 30.0 64.0 57.1 54.1 25.0 0.1 66.0 30.0 62.2 53.2 52.6 31.25 0.11 64.1 30.0 60.1 50.0 50.2 62.5 0.16 58.1 28.1 54.1 47.2 44.2 100.0 0.20 54.0 24.0 50.0 43.1 40.1 200.0 0.28 48.0 18.0 44.0 37.1 34.1 250.0 0.32 46.0 16.0 42.0 35.1 32.1 Ordering Information Ordering Number Description CP41-431-03N-E PegasusTM Cat.6 24P Unshielded modular patch panel (without keystone Jack) CP31-13C-11 PegasusTM Cat.6 Unshielded Pegasus tool-less keystone jack, black CP41-331-03N-E PegasusTM Cat.6 24P Shielded modular patch panel (without keystone Jack) CP31-532-24 PegasusTM Cat.6 Shielded tool-less keystone jack HDCS® DATA CENTER Draco Cat.6a Cabling System TM Application HDCS® DracoTM provides Cat.6a products a guaranteed 500MHz bandwidth for high-grade 10Gbps transmission application, and is backwards compatible with all current Ethernet applications, including 10BASE-T, 100BASE-T, 1000BASE-T, etc. Features • Shielded and unshielded for customer choice • Excellent short link performance based on unique design • Backward compatible with Cat.6 and Cat.5e components • Meets the requirements of TIA 568C.2 • More flexible with Modular structure • RoHS-compliant Mechnical Data • Mating cycles (RJ45 jack): ≥750 times • IDC termination cycles: ≥200 times • IDC applicable conductor: 22-26AWG solid • Working Temperature: -40ºC to +70ºC High Frequency Performance Ordering Information As per EIA/TIA 568C.2, at 20ºC Frequency (MHz) NEXT (dB) RL (dB) PSANEXT (dB) Min. Min. Min. 1.0 94.0 68.0 110.0 4.0 82.0 56.0 98.0 Ordering Number Products Description CP31-17E-14 DracoTM Cat.6a unshielded 90 degree keystone Jack, Ivory CP31-171-24 DracoTM Cat.6a unshielded standard 180 degree keystone Jack, Ivory CP31-271-24 DracoTM Cat.6a shielded standard 180 degree keystone Jack, Ivory CP31-572-24 DracoTM Cat.6a shielded tool-less 180 degree keystone Jack, Ivory CP41-451-03 DracoTM Cat.6a unshielded modular patch panel, 24-port with keystone Jack CP41-451-03-E DracoTM Cat.6a unshielded modular patch panel, 24-port without keystone Jack CP41-351-03 DracoTM Cat.6a shielded modular patch panel, 24-port with keystone Jack CP41-351-03N-E DracoTM Cat.6a shielded modular patch panel, 24-port without keystone Jack 8.0 75.9 49.9 91.9 10.0 74.0 48.0 90.0 16.0 69.9 43.9 85.9 20.0 68.0 42.0 84.0 25.0 66.0 40.0 82.0 31.25 64.1 38.1 80.1 62.5 58.1 32.1 74.1 100.0 54.0 28.0 70.0 200 48.0 22.0 64.0 250 46.0 20.0 62.0 CP61-431-1X DracoTM Cat.6a UTP patch cord, PVC Jacket 300 44.5 18.5 60.5 CP61-431-2X DracoTM Cat.6a UTP patch cord, LSZH Jacket 350 43.1 17.1 59.1 CP64-431-1X DracoTM Cat.6a FTP patch cord, PVC Jacket 400 42.0 16.0 58.0 CP64-431-2X DracoTM Cat.6a FTP patch cord, LSZH Jacket 450 40.9 14.9 56.9 500 40.0 14.0 56.0 Note: ‘X’ stands for length, 1=1meter, 2=2 meters, 3=3 meters HDCS® DATA CENTER Apus Cat.6 UTP and FTP Cable TM TM Apus Cat.6 UTP Data Cable Features HDCS® ApusTM indoor and outdoor Cat.6 UTP cables are designed for unshielded cabling systems. HDCS® ApusTM Cat.6 cables exceed requirements of TIA 568-C.2 and ISO/IEC118012nd-Edition with significant margins on all parameters. Cables are available in different jacket materials of various flame-retardant levels. Construction Construction: 4×2×AWG23 Conductor: AWG 23 Solid copper Insulation: HDPE Core: 4 twist pairs Sheath: PVC, LSZH or PE Colour: Grey, Orange, and Black Nominal Diameter: 6.3 mm Application Electrical Performance at 20ºC ApusTM Cat.6 Data Cable for structured premise cabling transmits DC resistance ≤9.38ohm/100m voice, data and video signals. It supports current high-bandwidth Unbalanced resistance ≤5% applications, and is especially suitable for applications of Fast- Unbalance capacitance ≤330pF/100m Ethernet. Capacitance ≤5.6nF/100m • VoIP Dielectric strength DC 1kv (3s No Fail) • ISDN Insulation resistance ≥5000Mohm.Km • Token ring Impedance • 100 Mbps TP-PMD • Analog and digital video Delay skew 1-250MHz (100±15) ohm 250-600MHz (100±25) ohm ≤45ns • TR-16 active and passive • 155 Mbit /622Mbit /1.2 Gbit ATM • 10baseT/100baseTX Fast /1000baseTX Gigabit Ethernet Mechanical Performance at 20ºC Bending radius During installation (min.) 8×outer diameter Installed (min.) 4×outer diameter Temperature range HDCS® DATA CENTER During installation 0ºC to +50ºC Installed -20ºC to +60ºC High-Frequency Performance at 20ºC Frequency (MHz) Attenuation (dB/100m) NEXT (dB) RL (dB) PSNEXT (dB) ELFEXT (dB) PSELFEXT (dB) ACR (dB) Propagation delay (ns/100m) Max. Min. Min. Min. Min. Min. Min. Max. 1.0 2.0 74.3 20.0 72.3 67.8 64.8 72 570.0 4.0 3.8 65.3 23.0 63.3 55.8 52.8 61 552.0 8.0 5.3 60.8 24.5 58.8 49.7 46.7 55 546.7 10.0 6.0 59.3 25.0 57.3 47.8 44.8 53 545.4 16.0 7.6 56.2 25.0 54.2 43.7 40.7 49 543.0 20.0 8.5 54.8 25.0 52.8 41.8 38.8 46 542.0 25.0 9.5 53.3 24.3 51.3 39.8 36.8 44 541.2 31.25 10.7 51.9 23.6 49.9 37.9 34.9 41 540.4 62.5 15.4 47.4 21.5 45.4 31.9 28.9 32 538.6 100.0 19.8 44.3 20.1 42.3 27.8 24.8 25 537.6 150 24.7 41.7 18.9 39.7 24.3 21.3 16.9 536.9 200 29.0 39.8 18.0 37.8 21.8 18.8 10.8 536.5 250 32.8 38.3 17.3 36.3 19.8 16.8 5.5 536.3 300 35.0 37.5 17.0 35.5 19.2 15.5 2.5 536.1 600 53.1 33.0 15.0 32.5 11.0 9.5 -20 535.5 Characteristic Graph Ordering Information Order Number Description CP11-141-12* ApusTM Cat.6 indoor UTP cable, CM, 305m (Box) CP11-141-13 ApusTM Cat.6 indoor UTP cable, LSZH, 305m (Reel in box) CP11-141-14* ApusTM Cat.6 indoor UTP cable, CMR, 305m (Box) CP11-141-16* ApusTM Cat.6 outdoor UTP cable, PE, 305m (Reel) CP12-141-11 ApusTM Cat.6 outdoor UTP cable, PE, 305m (Reel) HDCS® DATA CENTER Apus Cat.6 UTP and FTP Cable TM TM Apus Cat.6 FTP Data Cable Features and Benefits HDCS® ApusTM indoor and outdoor Cat.6 FTP cables are designed for shielded cabling systems. HDCS® ApusTM Cat.6 cables exceed TIA 568-C.2 and ISO/IEC11801 2nd requirements for Cat.6 performance by significant margins on all parameters. Cables are available in different jacket materials of various flame-retardant levels. Construction Construction: 4×2×AWG23 Conductor: AWG 23 solid copper Insulation: HDPE Core: 4 twist pairs Foil: PET tape Screen: AL/PET tape Drain wire: AWG23 tinned copper (Lay longitudinally under the AL/PET tape) Sheath: PVC, LSZH or PE Colour: Grey, Orange, and Black Nominal diameter: 7.4 mm Application Electrical Performance at 20ºC ApusTM Cat.6 Data Cable for structured premise cabling transmits DC resistance ≤7.5 ohm/100m voice, data and video signals. It supports current high-bandwidth Unbalanced resistance ≤5% applications, and is especially suitable to shielded Class E Solu- Unbalance capacitance ≤330pF/100m tions. Capacitance ≤5.6nF/100m • VoIP Dielectric strength DC 1kv, 3s No Fail • ISDN Insulation resistance ≥5000MΩ.km • Token ring Impedance (100±15) ohm • 100 Mbps TP-PMD Delay skew ≤45 • Analog and digital video • TR-16 active and passive • 155 Mbps /622Mbit /1.2Gbps ATM • 10baseT/100baseTX Fast /1000baseTX Gigabit Ethernet Mechanical Performance at 20ºC Bending radius During installation (min.) 8×outer diameter Installed (min.) 4×outer diameter Temperature range HDCS® DATA CENTER During installation 0ºC to +50ºC Installed -20ºC to +60ºC High-Frequency Performance at 20ºC Frequency (MHz) Attenuation (dB/100m) NEXT (dB) RL (dB) PSNEXT (dB) ELFEXT (dB) PSELFEXT (dB) ACR (dB) Propagation delay (ns/100m) Max. Min. Min. Min. Min. Min. Min. Max. 1.0 2.0 74.3 20.0 72.3 67.8 64.8 72 570.0 4.0 3.8 65.3 23.0 63.3 55.8 52.8 61 552.0 8.0 5.3 60.8 24.5 58.8 49.7 46.7 55 546.7 10.0 6.0 59.3 25.0 57.3 47.8 44.8 53 545.4 16.0 7.6 56.2 25.0 54.2 43.7 40.7 49 543.0 20.0 8.5 54.8 25.0 52.8 41.8 38.8 46 542.0 25.0 9.5 53.3 24.3 51.3 39.8 36.8 44 541.2 31.25 10.7 51.9 23.6 49.9 37.9 34.9 41 540.4 62.5 15.4 47.4 21.5 45.4 31.9 28.9 32 538.6 100.0 19.8 44.3 20.1 42.3 27.8 24.8 25 537.6 150 24.7 41.7 18.9 39.7 24.3 21.3 16.9 536.9 200 29.0 39.8 18.0 37.8 21.8 18.8 10.8 536.5 250 32.8 38.3 17.3 36.3 19.8 16.8 5.5 536.3 300 35.0 37.5 17.0 35.5 19.2 15.5 2.5 536.1 600 53.1 33.0 15.0 32.5 11.0 9.5 -20 535.5 Ordering Information Order Number Description CP12-241-11 ApusTM Cat.6 outdoor FTP cable, PE, 305m CP11-241-12 ApusTM Cat.6 indoor FTP cable, CM, 305m CP11-241-13 ApusTM Cat.6 indoor FTP cable, LSZH, 305m CP11-241-14 ApusTM Cat.6 indoor FTP cable, CMR, 305m CP11-241-16 ApusTM Cat.6 indoor FTP cable, CMP, 305m HDCS® DATA CENTER Draco Cat.6a UTP and FTP Cable TM TM Draco Cat.6a (10G) UTP Data Cable Features HDCS® DracoTM indoor and outdoor Cat.6a 10G UTP cables are designed for unshielded cabling systems. HDCS® DracoTM 10G UTP cables exceed requirements of TIA/EIA-568-C.2 and ISO/IEC11801-2nd-Edition with significant margins on all parameters specified specifically for 10G applications, with a testing frequency up to 500MHz. Cables are available with different jacket materials (CM, CMR, LSZH, CMP, etc.) of various flameretardant levels. Construction Construction: 4×2×AWG23 Conductor: AWG 23 solid copper Insulation: HDPE Core: 4 twist pairs Sheath: PVC, LSZH or PE CMR as per UL 1666 LSZH as per IEC60332-1, 60332-3, 61034-2, 60754-2 CMP as per UL 910 Color: Grey (CM, CMR, CMP), Orange (LSZH) Nominal Diameter: 8.6 mm Application: Electrical Performance at 20ºC DC resistance ≤7.32ohm/100m transmits voice, data and video signals. It supports current and Unbalanced resistance ≤5% future high-bandwidth applications, and is especially suitable for Unbalance capacitance ≤330pF/100m application of Class E. Capacitance ≤5.6nF/100m • VoIP Dielectric strength DC 1kv (3s No Fail) • ISDN Insulation resistance ≥5000Mohm.Km • Token ring Impedance ® HDCS Draco TM Cat.6a Data Cable for structured premise cabling • 100 Mbps TP-PMD • Analog and digital video Delay skew 1-250MHz (100±15) ohm 250-600MHz (100±25) ohm ≤45ns • TR-16 active and passive • 155 Mbps /622Mbit /1.2 Gbps ATM • 10baseT/100baseTX Fast /1000baseTX Gigabit Ethernet Mechanical Performance at 20ºC Bending radius During installation (min.) 8×outer diameter Installed (min.) 4×outer diameter Temperature range HDCS® DATA CENTER During installation 0ºC to +50ºC Installed -20ºC to +60ºC Transmission Performance (20ºC) Frequency (MHz) Attn (dB/100m) NEXT (dB) RL (dB) PSNEXT (dB) ELFEXT (dB) PSELFEXT (dB) ACR (dB) Propagation delay (ns/100m) Max. Min. Min. Min. Min. Min. Min. 1.0 2.0 89.9 20.0 88.3 67.8 64.8 87.9 570.0 4.0 3.6 81.3 23.6 79.3 55.8 52.8 77.7 552.0 8.0 5.0 76.8 25.4 74.8 49.7 46.7 71.7 546.7 10.0 5.6 75.3 26.0 73.3 47.8 44.8 69.7 545.4 16.0 7.1 72.2 26.0 70.2 43.7 40.7 65.1 543.0 20.0 8.0 70.8 26.0 68.8 41.8 38.8 62.8 542.0 25.0 9.0 69.3 25.3 67.3 39.8 36.8 60.4 541.2 31.25 10.1 67.9 24.6 65.9 37.9 34.9 57.8 540.4 62.5 14.5 63.4 22.5 61.4 31.9 28.9 48.8 538.6 100.0 18.7 60.3 21.1 58.3 27.8 24.8 41.6 537.6 125 21.1 59.8 20.4 57.8 25.9 22.9 38.7 536.2 200 27.5 56.8 19.0 54.8 21.8 18.8 29.3 536.5 250 31.1 55.3 18.3 53.3 19.8 16.8 24.2 536.3 300 34.6 55.1 17.8 53.1 18.3 15.3 20.6 536.1 400 40.8 53.3 16.9 51.3 15.8 12.8 12.5 535.8 500 46.5 51.8 16.2 49.8 13.8 10.8 5.3 535.6 Ordering Information Ordering Number Products Description CP11-171-12 DracoTM Cat.6a indoor UTP cable, CM, 305m CP11-171-13 DracoTM Cat.6a indoor UTP cable, LSZH, 305m CP11-171-14 DracoTM Cat.6a indoor UTP cable, CMR, 305m CP11-171-16 DracoTM Cat.6a indoor UTP cable, CMP, 305m HDCS® DATA CENTER Draco Cat.6a UTP and FTP Cable TM TM Draco Cat.6a (10G) FTP Data Cable Features and Benefits HDCS ® Draco TM Cat.6a (10G) FTP cables are designed for unshielded cabling systems. HDCS® DracoTM10G FTP cables exceed requirements of TIA/EIA-568-C.2 and ISO/IEC118012nd-Edition with significant margins on all parameters specified specifically for 10G applications, with a testing frequency up to 500MHz. Cables are available with different jacket materials (CM, CMR, LSZH, CMP, etc.) of various flame-retardant levels. Construction Construction: 4×2×AWG23 Conductor: AWG 23 solid copper Insulation: HDPE Core: 4 twist pairs Wrap tape: PET Grounding wire: 23AWG tinned copper conductor Shielding: AL/PET tape Sheath: PVC, LSZH or PE CMR as per UL 1666 LSZH as per IEC60332-1,60332-3,61034-2 ,60754-2 CMP as per UL 910 Color: Grey (CM, CMR, CMP), Orange (LSZH) Nominal Diameter: 7.6 mm Application Electrical Performance at 20ºC HDCS® DracoTM Cat.6a Data Cable for structured premise cabling DC resistance ≤7.32ohm/100m transmits voice, data and videosignals. It supports current and Unbalanced resistance ≤5% future high-bandwidth applications, and is especially suitable for Unbalance capacitance ≤330pF/100m application of Class E. Capacitance ≤5.6nF/100m • VoIP Dielectric strength DC 1kv (3s No Fail) • ISDN Insulation resistance ≥5000Mohm.Km • Token ring Impedance • 100 Mbps TP-PMD • Analog and digital video Delay skew 1-250MHz (100±15) ohm 250-500MHz (100±25) ohm ≤45ns • TR-16 active and passive • 155 Mbps /622Mbit /1.2 Gbps ATM Mechanical Performance at 20ºC • 10baseT/100baseTX Fast /1000baseTX Gigabit Ethernet Bending radius During installation (min.) 8×outer diameter Installed (min.) 4×outer diameter Temperature range HDCS® DATA CENTER During installation 0ºC to +50ºC Installed -20ºC to +60ºC Transmission Performance (20ºC) Frequency (MHz) Attn (dB/100m) NEXT (dB) RL (dB) PSNEXT (dB) ELFEXT (dB) PSELFEXT (dB) ACR (dB) Propagation delay (ns/100m) Max. Min. Min. Min. Min. Min. Min. 1.0 2.0 89.9 20.0 88.3 67.8 64.8 87.9 570.0 4.0 3.6 81.3 23.6 79.3 55.8 52.8 77.7 552.0 8.0 5.0 76.8 25.4 74.8 49.7 46.7 71.7 546.7 10.0 5.6 75.3 26.0 73.3 47.8 44.8 69.7 545.4 16.0 7.1 72.2 26.0 70.2 43.7 40.7 65.1 543.0 20.0 8.0 70.8 26.0 68.8 41.8 38.8 62.8 542.0 25.0 9.0 69.3 25.3 67.3 39.8 36.8 60.4 541.2 31.25 10.1 67.9 24.6 65.9 37.9 34.9 57.8 540.4 62.5 14.5 63.4 22.5 61.4 31.9 28.9 48.8 538.6 100.0 18.7 60.3 21.1 58.3 27.8 24.8 41.6 537.6 125 21.1 59.8 20.4 57.8 25.9 22.9 38.7 536.2 200 27.5 56.8 19.0 54.8 21.8 18.8 29.3 536.5 250 31.1 55.3 18.3 53.3 19.8 16.8 24.2 536.3 300 34.6 55.1 17.8 53.1 18.3 15.3 20.6 536.1 400 40.8 53.3 16.9 51.3 15.8 12.8 12.5 535.8 500 46.5 51.8 16.2 49.8 13.8 10.8 5.3 535.6 Ordering Information Ordering Number Products Description CP11-271-12 DracoTM Cat.6a indoor FTP cable, CM, 305m CP11-271-13 DracoTM Cat.6a indoor FTP cable, LSZH, 305m CP11-271-14 DracoTM Cat.6a indoor FTP cable, CMR, 305m CP11-271-16 DracoTM Cat.6a indoor FTP cable, CMP, 305m HDCS® DATA CENTER