HE2XINV Indoor Unit Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 500-2,200 CFM AHRI 1060 Certified Core: Two L125-00 Airflow Rating Points (for AHRI): 1,500 CFM and 1,126 CFM Number Motors: Two belt drive blower/motor packages with adjustable sheaves G5 Performance Effectiveness (%) 500 Drive HP Volts HZ Phase 1.5 115 208-230 208-230 460 575 60 60 60 60 60 Single Single Three Three Three 2.0 115 208-230 208-230 460 575 60 60 60 60 60 Single Single Three Three Three CFM 1,000 1,500 2,000 80 Sensib Winter 60 Summ le Total Max. Overcurrent Protection Device 15.2 8.2-7.6 4.6-4.8 2.4 1.8 34.2 18.5 10.8 5.4 4.1 45 25 15 15 15 20.0 10.8-10.0 6.1-5.8 2.9 2.4 45.0 24.3 13.6 6.5 5.4 60 35 15 15 15 (per motor) Standard Features: Totally Enclosed Premium Efficiency Motors Motor Starters, Non-fused Disconnect 24 VAC Transformer/Relay Package Optional Factory Installed VFD Electrical Specifications er To 40 Min. Cir. Amps FLA tal 1.5 208-230 208-230 460 575 60 60 60 60 Single Three Three Three 4.6-4.8 4.6-4.8 2.4 1.8 20.6 11.9 5.9 4.5 25 15 15 15 2.0 208-230 208-230 460 575 60 60 60 60 Single Three Three Three 6.1-5.8 6.1-5.8 2.9 2.4 26.0 15 7.2 5.9 30 15 15 15 *At AHRI 1060 standard conditions (See certified data on page 73 for core components.) Filters: Four total, MERV 8, 2” pleated, 20” x 20” nominal size Weight: 427 lbs (unit), 500 lbs (shipping weight, on pallet) Shipping Dimensions: 62” L x 48” W x 60” H Options: Fused disconnect Double wall construction Factory supplied and mounted Variable Frequency Drives (VFDs) – one or both airstreams Motorized isolation dampers, OA, EA or both airstreams Factory mounted Filter Alarms (2) Airflow Performance Motor HP 1.5 2 Blower RPM Turns Open 1146 1302 1458 1503 1581 1658 4 2 0 2 1 0 0.00 SCFM BHP 1735 0.8 1975 1.1 0.25 SCFM BHP 1670 0.7 1925 1.1 External Static Pressure (in. w.g.) 0.50 0.75 1.00 SCFM BHP SCFM BHP SCFM BHP 1520 0.7 1205 0.5 900 0.4 1835 1.0 1615 0.9 1340 0.8 2100 1.5 1970 1.4 1755 1.3 2175 1.7 2100 1.6 1945 1.4 2120 1.7 Note: Brake Horse Power (BHP) is for one blower motor package only. Operation in this zone outside of core airflow limits. Operation in this zone will likely exceed FLA limits. 24 (800) 627-4499 • Fax: (608) 221-2824 1.25 SCFM BHP 1.50 SCFM BHP 1080 1495 1700 1920 2125 670 1280 1465 1685 1900 0.6 1.1 1.2 1.5 1.9 0.4 0.9 1.0 1.2 1.6 For the most complete and current information visit www.RenewAire.com 25 12" X 16" DUCT FLANGE FA Damper Location (Optional) 14" X 24" LEFT VIEW 36 1/4" Wiring Inlets FA RA Unit Dimensions HE2XINV 10 1/8" E-Box Power Wire Ø7/8" 4 1/4" FA Disconnect Switch 45 1/8" FRONT VIEW 35 1/4" with screws 51 5/8" 12" X 16" DUCT FLANGE 2 5/8" Control In 5 3/4" Power In 4 1/4" EA OA Pressure Taps (4) 14" X 24" DUCT FLANGE 46 1/2" TOP VIEW and Service Area RA 74 7/8" Clear 14" EA Damper Location (Optional) 2 1/2" 12" 37 7/8" 8 1/8" Exhaust Air to outdoors Outdoor Air intake Room Air to be exhausted Fresh Air to inside RIGHT VIEW 16" EA OA 24" 41 5/8" EA: OA: RA: FA: