Preview only show first 10 pages with watermark. For full document please download

He4xrtc Submittal

   EMBED


Share

Transcript

HE4XRTC Specifications Outdoor Unit Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 2,500-3,900 CFM AHRI 1060 Certified Core: Four L125-00 Airflow Rating Points (for AHRI): 3,000 CFM and 2,250 CFM Number Motors: Two belt drive blower/motor packages with adjustable sheaves CFM Effectiveness (%) 2,000 Volts HZ Phase 5 208-230 460 575 60 60 60 Three Three Three 3,000 80 Sensib r Tota 60 Sum l mer 40 208-230 460 575 Tota l Fresh Air 1825 1770 1715 1660 1605 1550 1495 0 1 2 3 4 5 6 14.5-13.4 6.7 5.3 35.9 16.6 13.1 45 20 15 Unit Tied Into Return of Air Handler Unit Tied Into Separate Ducts Static Pressure in Adjacent Air Handler (Inches Water Column) External Static Pressure (Inches Water Column) -0.75 -0.5 -0.25 0.0 +0.25 +0.5 +0.75 CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 3400 3275 3125 2935 2780 2685 2620 3.1 3.0 2.8 2.3 2.0 1.6 1.4 3700 3600 3450 3300 3150 3050 2950 3.3 3.2 2.9 2.5 2.3 2.0 1.7 4000 3925 3775 3665 3520 3415 3280 3.6 3.4 3.0 2.8 2.5 2.4 2.0 4250 4225 4156 4067 3900 3760 3600 4.1 3.8 3.6 3.4 3.1 2.8 2.4 4000 3925 3775 3665 3520 3415 3280 3.6 3.4 3.0 2.8 2.5 2.4 2.0 3700 3600 3450 3300 3150 3050 2950 3.3 3.2 2.9 2.5 2.3 2.0 1.7 3400 3275 3125 2935 2780 2685 2620 3.1 3.0 2.8 2.3 2.0 1.6 1.4 4.6 4.1 3.7 3.4 2.9 3225 3140 3060 2970 2890 2790 4.9 4.5 4.0 3.7 3.3 2.8 3245 3125 3005 2940 2850 2770 2670 5.0 4.6 4.3 3.9 3.7 3.3 2.8 3920 3790 3724 3680 5.0 4.6 4.2 4.2 3760 3670 3582 3500 5.0 4.6 4.3 4.1 3600 3550 3440 3320 5.0 4.7 4.5 3.9 Note: Brake Horse Power (BHP) is for one blower motor package only. Operation in this zone will likely exceed FLA limits. 60 Three Three Three Fused disconnect Double wall construction Factory supplied and mounted Variable Frequency Drives (VFDs) – one or both airstreams Factory mounted Filter Alarms (2) Exterior paint – white standard – custom colors available Rooftop RTC transition paint – white standard – custom colors available Airflow Performance Exhaust Air 60 60 60 Shipping Dimensions: 90” L x 72” W x 78” H *At AHRI 1060 standard conditions (See certified data on page 73 for core components.) 0 1 2 3 4 5 6 45 20 15 Weight: 991 lbs (unit), 1,125 lbs (shipping weight, on pallet) Options: 1510 1465 1420 1375 1330 1285 1240 32.6 15.1 11.9 Filters: Six total, MERV 8, 2” pleated, four 20” x 20”, and two 16” x 25” nominal size le Winte Turns Open 14.5-13.4 6.7 5.3 Max. Overcurrent Protection Device Optional Factory Installed VFD Electrical Specifications 4,000 5 Blower RPM Nominal (per motor) Min. Cir. Amps Standard Features: Totally Enclosed Premium Efficiency Motors Motor Starters, Non-fused Disconnect 24 VAC Transformer/Relay Package G5 Performance 1,000 HP FLA (800) 627-4499 • Fax: (608) 221-2824 3450 3360 3270 3190 3100 4.8 4.5 4.1 3.6 3.5 3275 3180 3090 3010 2910 For the most complete and current information visit www.RenewAire.com 61 EA LEFT VIEW 72 5/8" Power & Control Wiring Inlets OA Unit Dimensions HE4XRTC Core and EA Blower Access RA Filter Access RA FA 82 1/4" 36 3/8" Service Area RA FA FRONT VIEW EA Blower Access 80 3/4" 57 1/2" TOP VIEW 82 1/4" Service Area (Power) 5 3/4" (Control) 2 5/8" OA EA EA (2) Ø7/8" Wiring Inlets E-box 139 1/2" Service Area OA 46 1/2" OA Blower and Filter Access 81 3/4" RIGHT VIEW RA FA 37" 25 1/2" 45" Exhaust Air to outdoors Outdoor Air intake Room Air to be exhausted Fresh Air to inside 6 1/2" 11 1/4" typ EA: OA: RA: FA: