Transcript
Environmental Stress Chamber
AR series
CAT.NO.E14141
Advanced reliability Environmental Stress Chambers AR series has big allowable heat loads generated by the specimen, and achieves improved temperature change rate in an expanded temperature and humidity range. The new N-instrumentation allows AR series chambers to support easy-to-use networking system. ESPEC offers two temperature control ranges: −75℃ to +180℃ or −45℃ to +180℃, with or without humidity control (10 to 98%rh). These models incorporate the most desirable features in temperature and humidity chambers.
ARS−0220
1
ARS−1100
*Viewing window is optional.
Characteristics Superior temperature heating and cooling control at 3℃ /min. with specimen load
Te mp e r at u re he at i ng a nd c o ol i ng performance at 4 to 6℃ /min. (no load), and can handle temperature cycle tests at 3℃ /min. (with load*) * ARS-1100 specimen: aluminum 38kg (including shelf 12kg)
Highly uniform temperature distribution
Temperature change rate Model
Heat up (K/min.)
Pull down (K/min.)
ARL/ARU −0680
6.3
4.8
ARL/ARU −1100
4.7
4.4
ARS/ARG−0220
6.0
5.2
ARS/ARG−0390
5.0
4.0
ARS/ARG−0680
6.0
4.2
ARS/ARG−1100
4.7
4.1
*At ambient temperature, +20℃ no specimen.
Temperature & Humidity Control Range
Highly uniform temperature distribution minimizes variations in test results.
(ambient temperature at +20℃ with no load) 100 90 80 Relative 70 Humidity 60 (%rh) 50 40 30 20 10 0
Reduced temperature and humidity stabilization time
Temperature and humidity stabilization time is greatly reduced by minimizing hunting as the chamber approaches setpoint. (under testing operation from RT to 85℃ /85% rh).
Wider control range for temperature and humidity
Feat u res a w ider cont rol r a nge of temperature and humidity, including stable control at 95℃ /98% rh.
Meets international standards
Desig ned to comply with major environmental test standards such as IEC60068-2, or ISO16750-4 (5.3). (Refer to compatible test standards)
International safety standard compliance
Complies with Safety of Machinery (ISO 12100), Low Voltage (IEC 60204), EMC (IEC 61000-6-2, IEC 61000-6-4).
98
ARS・ARL
10
20
30
40 50 60 70 Temperature (℃)
80
90 100 95
*Continuous operation at or below +40℃ is limited because of frost formation on the cooler and dehumidifier.
●
Compatible Test Standards Cold ・IEC60068-2-1: Dry heat ・IEC60068-2-2: Damp heat, steady state ・IEC60068-2-3: PR・PL・PSL ・IEC60068-2-14 Nb: Change of temperature with specified rate of change * Composite temperature/ humidity ・IEC60068-2-38: cyclic test * Damp heat, steady state ・IEC60068-2-78: Temperature cycling ・ISO16750-4 5.3:
2
Characteristics Supports heat loads up to 4500W*
(During temperature testing) Supports electrically-charged specimens, and can compensate up to 4500W of heat load during temperature testing, depending on the chamber model (500W du r i ng t empe r at u re a nd hu m id it y testing). * Test area temperature:+20℃
User-friendly features
Standard features include cable ports on both sides which allow free access of the test area. Antirust and oil proof 18-8 Cr-Ni stainless steel plate is used as external panels. It is possible to select water supply via water tank or direct water coupling alliteratively all the time.
Cable ports on both walls
Chamber restricted to lock the door
It is now possible to lock the chamber door to prevent accidental operation of the chamber during testing. The handle part design has also been improved so the door closing is easier and safer.
Water tank
3
Key
New refrigeration circuit and condenser filter improves reliability
Thanks to newly designed refrigeration circuit, reliability is improved. And further more condenser filter, prevents a condenser fan from clogging becomes standard equipment.
Controller
N-instrumentation
N-instrumentation equipped with a color LCD touch panel
Interior light
Wide 7-inch screen with LED backlight is clearer and provides faster display speed.
Interior light button
It is able to switch ON/OFF from the interior light button any time.
Information button
Touch navigation
When there are some things need to be notified to the operator, information button will alart to the operator. By pressi ng the but ton, you will f i nd notifications such as "Check Humidity Tray".
Touch icon to show navigation bar.
Application of USB MEMORY Continous record test data Data transfer Copy test program USB memory port
Trend graph output on USB memory
Trend graphs can be displayed on the web application or downloaded on USB m e m o r y. I t i s a l s o p o s s i b l e t o continuously register data on USB memory if numerous data records are needed.
N-instrumentation Display
TFT Color LCD (7.0inch)
Operating mode
Constant operation, Program operation, Remote operation, Stop
Setting range
Constant setup: 3 patterns Setting range: Temp.: −80.0℃ to +185.0℃, 0.1℃ unit (ARS, ARG) Temp.: −50.0℃ to +185.0℃, 0.1℃ unit (ARL, ARU) Humidity: 0 to 100% rh, 1% unit (ARS, ARL) ● Program setup: 40 patterns (99 steps) Setting range: Temp.: −80.0℃ to +185.0℃, 0.1℃ unit (ARS, ARG) −50.0℃ to +185.0℃, 0.1℃ unit (ARL, ARU) Humidity: 0 to 100% rh, 1% unit Time: 0 hour and 1 min. to 9999 hours and 59 min. 1 min. unit
Language
Japanese, English, Chinese (simplified, traditional), Korean
Interface
USB 2.0 standard compliant (A-type connector)
External memory function
Write sampling data, Read/ Write program, Backtrace output, Add-on/system updates
Network function
Interface: Ethernet port (100base-TX)
Web function
Monitoring, setting, operation, Data Record Function, maintenance setting, email alert
Browser
Windows Internet Explorer10
●
4
Network Remote monitoring and control thanks to a Web application Remote monitoring and control (Ethernet connection)
A unique web application allows the u s e r t o mo n it or t he ch a mb e r, s e t programs, and start and stop operation from a PC connected to the chamber Ethernet port (LAN’s port). No software required, the chamber can be accessed and cont rolled f rom PC via a web browser (Smartphone, tablets and the like can also be used). Wireless connection and multiple units connection are also possible.
Image
Login information Chamber monitor
Constant Mode/ Program Setup
Run/ Stop
Device configuration
Administrator
○
○
○
○
Operator
○
○
○
×
User
○
×
×
×
Privileges
Screen
○= available; ×= Not available
●
Program editing
●
Graph display
Email alert
When an alarm is triggered, an e-mail is sent to the registered PC or mobile address. A notification can also be sent at the time of test completion. *Requires an intranet environment capable of sending emails.
Multilingual display
The language available for the Web application (Japanese/ English/ Simplified Chinese/ Traditional Chinese/ Korean) can be changed without affecting the N-instrumentation language display.
Email alert
Ethernet
PC
PC
Intranet (company LAN)
携帯電話 スマートフォン Mail server
AR series
5
Program copy and computer editing
Mobile phone Smartphone
Environmental Stress Chamber
タブレットコントローラー (オプション)
Ethernet
Network
PC
Intranet (company LAN) Mail server
AR series
Mobile phone Smartphone
En Stre
Copy and reproduce testing
Program copy and computer editing Thanks to the USB memory you can copy the same test program in multiple chambers, provided that they have the Copy same operat ion range. No need to program each chamber, just connect the (別売) 2015年3月対応予定 集中管理システム :Web統合管理システム) USB and the test can(旧 start.
100台までの試験器の状態を1画面で確認することができる 集中管理システムに接続可能です。 Download edit programs online
Edit エスペック ネットワーク
検索
Via the Pattern Manager Lite software installed 事務棟 on your PC, edit programs試験棟 according to your testing needs, and ● Test Navi Ethernet upload them with a USB. (http://www.test-navi.com/eng/index.html)
Ethernet This website provides practical knowledge on environmental testing
クライアントPC
イントラネット
Edit programs
Through our online website Test Navi, dedicated to reliability Ethernet and testing information, you can find most of the recognized inter national standard, available for download. 集中管理システム Charge them as is on your USB memory, or edit them and transfer to your chamber. * Test Navi is a website dedicated to reliability testing information and technologies. http:// www.test-navi.com/eng/index.html
that ESPEC has acquired through years of experience, as well as covering everything from the fundamentals to the latest information on Network environmental and reliability testing. Wi-Fi router ハイパワー恒温 (恒湿) 器
Product Registration EthernetMembership Website Product Registration Ethernet ネットワークアダプター Membership Website ・ Updates for chamber controller software
PC
旧:RS-485 environmental test standards ・ Search forLANコンバーター プラチナスKシリーズ Tablet controller Environmental Test Smartphone AR series Standards For Pattern Manager LiteTest Environmental Test methods download
The Pattern Manager Lite software allows you to edit programs for your chamber, view and edit data as graph, etc. The software can be downloaded from the Test Navi website.
Standards
For Pattern Manager Lite Test methods download 検索 エスペック オンライン ・ Download test profiles from a list of environmental test standards
Web Integrated Network (Sold separately) Program copy and computer editing Maximum 100units of connected chambers and other peripherals necessary for environmental testing are manned via Internet. Product registration membership Website
Office
Lab Ethernet
Ethernet
Web integrated network system
Intranet
Client PC
Ethernet
Ethernet
Download Pattern Manager and WEB Manager information.
Product registration membership Website Download Pattern Manager and WEB Manager information.
Download
Copy
Access to video
Download
製品会員専用サイト パターンマネージャーの情報、 製品会員専用サイト ダウンロード WEBマネージャー情報のダウンロード
AR series パターンマネージャーの情報、 Edit WEBマネージャー情報のダウンロード ダウンロード
LAN converter 環境試験規格一覧 パターンマネージャーLite対応 Platinous K Series 環境試験規格一覧 試験条件プログラムパターンダウンロード
パターンマネージャーLite対応 試験条件プログラムパターンダウンロード
試験規格プログラムパターン ファイルの活用方法
6
ARL
−45 to +180℃・10 to 98%rh
TEMPERATURE & HUMIDITY CHAMBER
Model
ARL−0680
Temp. & humid. Temp. performance *1 performance *1
System
ARL−1100
Balanced Temperature & Humidity Control (BTHC) system −45 to +180℃ (−49 to +356℉)
Temp. range
±0.3K
Temp. fluctuation Temp. variation in space Heat up rate Temp. rate of change *2 Pull down rate
3.0K 6.3 K/min.
4.7 K/min.
4.8 K/min.
4.4 K/min. 4500 W Test area temperature: +20℃
Max. allowable heat load
+10 to +95℃ / 10 to 98%rh
Temp. & humid. range
±2.5%rh
Humid. fluctuation
500 W Test area conditions: +85℃ /85%rh
Max. allowable heat load Exterior material
18 Cr-stainless steel plate (Hairline finish)
Test area material
18-8 Cr-Ni Stainless steel plate (BA finish)
Insulation
Foamed phenol, glass wool Nichrome strip wire heater (3 kW×2)
Humidifier
Sheathed heater
Cooler Refrigeration unit
Construction
Heater
Plate fin cooler and dehumidifier
System
Mechanical single-stage refrigeration system
Refrigerator Refrigerator capacity
Scroll-type compressor 3.0 kw
3.75 kw
Expansion mechanism
Electronic expansion valve
Refrigerant
R404A
Air circulator
Sirocco fan
Interface
Ethernet 100mm cable port (×2), specimen power supply control terminal, condenser filter, specimen temperature input terminal, time signal (×2), casters with levelling feet (×4)
Fittings Capacity
680 L
1100 L
Chamber total load resistance
80 kg
150 kg
Inside dimensions mm (inch) *3
W850×H1000×D800 (W33.5×H39.4×D31.5)
W1100×H1000×D1000 (W43.3×H39.4×D39.4)
Outside dimensions mm (inch) *3
W1050×H1955×D1805 (W41.3×H77.0×D71.1)
W1300×H1955×D2005 (W51.2×H77.0×D78.9)
510 kg
600 kg
Utility requirements
Weight 200V AC 3φ50/60Hz
53 A
56 A
220V AC 3φ60Hz
49 A
52 A
23 A
25 A
400V AC 3φ50Hz *5
22 A
23 A
61 dB
62 dB
32400 (7743)
39600 (9464)
Power supply *4 380V AC 3φ50Hz
Noise level *6 Exhaust heat quantity kJ/h (kcal/h) *1: *2: *3: *4: *5: *6:
7
0 to +40℃ (+32 to +104℉) / 75%rh max.
Allowable ambient conditions
At ambient temperature +20℃, no specimen. Performance shown above conforms to IEC 60068-3-5:2001 and IEC 60068-3-6:2001. Temperature rate of change in the temperature range excluding ±10% of max/min. temperature. Excluding protrusions. Power supply voltage fluctuation to be ±10% of rated value. Conforms to CE marking based on EU directives. Measurements are to be taken in an anechoic room at a height of 1.2m from the floor and a distance of 1m from the chamber front panel (ISO 1996-1:2003 _ A-weighted sound pressure level).
ARS
−75 to +180℃・10 to 98%rh
TEMPERATURE & HUMIDITY CHAMBER
Model
ARS−0220
Temp. & humid. performance *1
Temp. performance *1
System
ARS−0390
ARS−1100
−75 to +180℃ (−103 to +356℉)
Temp. range
±0.3K
Temp. fluctuation Temp. variation in space Heat up rate Temp. rate of change *2 Pull down rate
3.0K 6.0 K/min.
5.0 K/min.
6.0 K/min.
4.7K/min.
5.2 K/min.
4.0 K/min.
4.2 K/min.
4.1K/min.
Max. allowable heat load
Test area temperature: +20℃
3000 W
Humid. fluctuation Max. allowable heat load
4500 W
+10 to +95℃ / 10 to 98%rh
Temp. & humid. range
±2.5%rh Test area conditions: +25 to +95℃ /90%rh 350 W 300 W
Test area conditions: +85℃ /85%rh 500 W
Exterior material
18 Cr-stainless steel plate (Hairline finish)
Test area material
18-8 Cr-Ni Stainless steel plate (BA finish)
Insulation
Foamed phenol, glass wool
Heater
Nichrome strip wire heater
(1.75 kW×2)
Humidifier
(3 kW×2)
Sheathed heater
Cooler Refrigeration unit
Construction
ARS−0680
Balanced Temperature & Humidity Control (BTHC) system
Plate fin cooler and dehumidifier
System
Mechanical cascade and compression refrigeration system
Refrigerator
Rotary compressor
Scroll compressor
Unit 1: 2.2 kw ×1, Unit 2: 2.2 kw ×1
Refrigerator capacity Expansion mechanism
Unit 1: 3.0 kw ×1, Unit 2: 3.0 kw ×1
Unit 1: 3.75 kw ×1, Unit 2: 3.75 kw ×1
Electronic expansion valve
Refrigerant
R404A, R508A
R404A, R23
Air circulator
Sirocco fan
Interface
Ethernet 100mm cable port (×2), specimen power supply control terminal, condenser filter, specimen temperature input terminal, time signal (×2), casters with levelling feet (×4)
Fittings Capacity
220 L
Chamber total load resistance
390 L
680 L
1100 L
50 kg
80 kg
80 kg
150 kg
Inside dimensions mm (inch) *3
W700×H800×D400 (W27.6×H31.5×D15.8)
W700×H800×D700 (W27.6×H31.5×D27.6)
W850×H1000×D800 (W33.5×H39.4×D31.5)
W1100×H1000×D1000 (W43.3×H39.4×D39.4)
Outside dimensions mm (inch) *3
W900×H1742×D1455 (W35.4×H68.6×D57.3)
W900×H1742×D1705 (W35.4×H68.6×D67.1)
W1050×H1955×D1805 (W41.3×H77.0×D71.1)
W1300×H1955×D2005 (W51.2×H77.0×D78.9)
405 kg
615 kg
700 kg
Utility requirements
Weight
390 kg 200V AC 3φ50/60Hz 220V AC 3φ60Hz
Power supply *4 380V AC 3φ50Hz
400V AC 3φ50Hz *5
Noise level *6 Exhaust heat quantity kJ/h (kcal/h) *1: *2: *3: *4: *5: *6:
0 to +40℃ (+32 to +104℉) / 75%rh max.
Allowable ambient conditions ─
─
63 A
70 A
38 A *5
38 A *5
58 A
64 A
24 A *5
24 A *5
28 A
32 A
23 A
23 A
27 A
29 A
57 dB
58 dB
62 dB
63 dB
26600 (6357)
26600 (6357)
39600 (9464)
46800 (11185)
At ambient temperature +20℃, no specimen. Performance shown above conforms to IEC 60068-3-5:2001 and IEC 60068-3-6:2001. Temperature rate of change in the temperature range excluding ±10% of max/min. temperature. Excluding protrusions. Power supply voltage fluctuation to be ±10% of rated value. Conforms to CE marking based on EU directives. Measurements are to be taken in an anechoic room at a height of 1.2m from the floor and a distance of 1m from the chamber front panel (ISO 1996-1:2003 _ A-weighted sound pressure level).
8
ARU
−45 to +180℃
TEMPERATURE CHAMBER
Model
ARU−0680
Temp. performance *1
System
−45 to +180℃ (−49 to +356℉)
Temp. range
±0.3 K
Temp. fluctuation Temp. variation in space Temp. rate of change *2
3.0 K
Heat up rate
6.3 K/min.
4.7 K/min.
Pull down rate
4.8 K/min.
4.4 K/min. 4500 W Test area temperature: +20℃
Max. allowable heat load Exterior material
18 Cr-stainless steel plate (Hairline finish)
Test area material
18-8 Cr-Ni Stainless steel plate (BA finish) Foamed phenol, glass wool
Heater
Nichrome strip wire heater (3kW ×2)
Cooler
Plate fin cooler
Refrigeration unit
Construction
Insulation
System
Mechanical single-stage refrigeration system
Refrigerator
Scroll-type compressor
Refrigerator capacity
3.0 kw
3.75 kw
Expansion mechanism
Electronic expansion valve
Refrigerant
R404A
Air circulator
Sirocco fan
Interface
Ethernet 100mm cable port (×2), specimen power supply control terminal, condenser filter, specimen temperature input terminal, time signal (×2), casters with levelling feet (×4)
Fittings Capacity Chamber total load resistance Inside dimensions mm (inch)
*3
Outside dimensions mm (inch) *3 Utility requirements
Weight
1100 L
80 kg
150 kg
W850×H1000×D800 (W33.5×H39.4×D31.5)
W1100×H1000×D1000 (W43.3×H39.4×D39.4)
W1050×H1955×D1805 (W41.3×H77.0×D71.1)
W1300×H1955×D2005 (W51.2×H77.0×D78.9)
505 kg
595 kg 0 to +40℃ (+32 to +104℉) / 75%rh max.
200V AC 3φ50/60Hz
53 A
56 A
220V AC 3φ60Hz
49 A
52 A
23 A
25 A
400V AC 3φ50Hz *5
22 A
23 A
Power supply *4 380V AC 3φ50Hz
Exhaust heat quantity kJ/h (kcal/h)
9
680 L
Allowable ambient conditions
Noise level *6 *1: *2: *3: *4: *5: *6:
ARU−1100
Balanced Temperature Control (BTC) system
61 dB
62 dB
32400 (7743)
39600 (9464)
At ambient temperature +20℃, no specimen. Performance shown above conforms to IEC 60068-3-5:2001. Temperature rate of change in the temperature range excluding ±10% of max/min. temperature. Excluding protrusions. Power supply voltage fluctuation to be ±10% of rated value. Conforms to CE marking based on EU directives. Measurements are to be taken in an anechoic room at a height of 1.2m from the floor and a distance of 1m from the chamber front panel (ISO 1996-1:2003 _ A-weighted sound pressure level).
ARG
−75 to +180℃
TEMPERATURE CHAMBER
Model
ARG−0220
ARG−0390
Temp. performance *1
System
ARG−1100
−75 to +180℃ (−103 to +356℉)
Temp. range
±0.3 K
Temp. fluctuation Temp. variation in space Temp. rate of change *2
3.0 K
Heat up rate
6.0 K/min.
5.0 K/min.
6.0 K/min.
4.7K/min.
Pull down rate
5.2 K/min.
4.0 K/min.
4.2 K/min.
4.1K/min.
Test area temperature: +20℃
Max. allowable heat load
3000 W
4500 W
Exterior material
18 Cr-stainless steel plate (Hairline finish)
Test area material
18-8 Cr-Ni Stainless steel plate (BA finish)
Insulation
Foamed phenol, glass wool Nichrome strip wire heater
Heater
(1.75 kW×2)
(3 kW×2)
Cooler Refrigeration unit
Construction
ARG−0680
Balanced Temperature Control (BTC) system
Plate fin cooler
System
Mechanical cascade refrigeration system
Refrigerator
Scroll-type compressor Unit 1: 2.2 kw ×1, Unit 2: 2.2 kw ×1
Refrigerator capacity Expansion mechanism
Unit 1: 3.0 kw ×1, Unit 2: 3.0 kw ×1
Unit 1: 3.75 kw ×1, Unit 2: 3.75 kw ×1
Electronic expansion valve
Refrigerant
R404A, R508A
R404A, R23
Air circulator
Sirocco fan
Interface
Ethernet 100mm cable port (×2), specimen power supply control terminal, condenser filter, specimen temperature input terminal, time signal (×2), casters with levelling feet (×4)
Fittings Capacity
220 L
390 L
680 L
1100 L
Chamber total load resistance
50 kg
80 kg
80 kg
150 kg
Inside dimensions mm (inch) *3
W700×H800×D400 (W27.6×H31.5×D15.8)
W700×H800×D700 (W27.6×H31.5×D27.6)
W850×H1000×D800 (W33.5×H39.4×D31.5)
W1100×H1000×D1000 (W43.3×H39.4×D39.4)
Outside dimensions mm (inch) *3
W900×H1742×D1455 (W35.4×H68.6×D57.3)
W900×H1742×D1705 (W35.4×H68.6×D67.1)
W1050×H1955×D1805 (W41.3×H77.0×D71.1)
W1300×H1955×D2005 (W51.2×H77.0×D78.9)
385 kg
400 kg
615 kg
700 kg
Utility requirements
Weight 200V AC 3φ50/60Hz 220V AC 3φ60Hz Power supply *4 380V AC 3φ50Hz 400V AC 3φ50Hz
─
─
63 A
70 A
38 A
38 A
*5
58 A
64 A
24 A *5
28 A
32 A
*5
24 A *5 *5
Noise level *6 Exhaust heat quantity kJ/h (kcal/h) *1: *2: *3: *4: *5: *6:
0 to +40℃ (+32 to +104℉) / 75%rh max.
Allowable ambient conditions
23 A
23 A
27 A
29 A
57 dB
58 dB
62 dB
63 dB
26600 (6357)
26600 (6357)
39600 (9464)
46800 (11185)
At ambient temperature +20℃, no specimen. Performance shown above conforms to IEC 60068-3-5:2001. Temperature rate of change in the temperature range excluding ±10% of max/min. temperature. Excluding protrusions. Power supply voltage fluctuation to be ±10% of rated value. Conforms to CE marking based on EU directives. Measurements are to be taken in an anechoic room at a height of 1.2m from the floor and a distance of 1m from the chamber front panel (ISO 1996-1:2003 _ A-weighted sound pressure level).
10
ACCESSORIES
SAFETY DEVICES
Cable port rubber plug (φ100 mm)
2 each
●
Shelf brackets stainless steel plate (18-8 Cr-Ni stainless steel)
1 set
●
Shelf stainless steel wire (18-8 Cr-Ni stainless steel) Door key
●
Cartridge fuse (Class B, 250 V 0.4 A, 5 A, 8 A)
1
●
2
●
1 each
●
Wet-bulb wick (ARL, ARS)
● ●
●
1 box (24 wicks)
●
Control circuit overcurrent protection Control circuit short circuit protection cartridge fuse System error Reverse-prevention relay Thermal fuse Temperature switch for air circulator Air circulator short circuit protection Ambient temperature input burn-out detection circuit Dry-bulb temperature input burn-out detection circuit Specimen temperature input burn-out detection circuit (only when using specimen temperature control)
●
Specimen temperature measuring thermocouple (type T, 3m)
1
●
Specimen temperature input connector
●
● ● ● ●
1
●
Operation manual
1
●
Condenser fan short circuit protection Condenser fan overload protection Refrigerator temperature sensor burned detect circuit Refrigerator short circuit protection Refrigerator overcurrent protection Refrigerator discharge pipe temperature switch (0680/1100) Refrigerator high (low) pressure switch Refrigerator frost detection cicuit (0680/1100) Refrigerator circuit temperature range over Refrigerator frost trouble detection temperature switch (ARS-0680/1100, ARG-0680/1100)
● ● ●
SHELVES SIZE AND LOAD RESISTANCE Model
0220
0390
0680
1100
Shelf size (mm)
W667 D350
W667 D650
W817 D750
W1067 D950
Shelf weight
2 kg
3 kg
6 kg
12 kg
Shelf load capacity (evenly distributed load)
30 kg
30 kg
40 kg
50 kg
Shelf support max. load (Including shelf weight)
50 kg
80 kg
80 kg
100 kg
● ● ● ● ● ● ●
Refrigerator discharge pipe temperature trouble detection circuit (ARS, ARG)
●
Heater (humidifier) leak current protection
●
Wet bulb temperature input burnout detection circuit (ARL, ARS)
●
Humidifier boil-dry protector (ARL, ARS) Humidifier water level detector (ARL, ARS) Water tank empty switch (ARL, ARS) Water tank low level switch (ARL, ARS) Dry wick detection (ARL, ARS) Overheat protector High deviation temperature alarm (built into temperature and humidity controller)
● ● ● ● ● ● ●
High/ low absolute temperature (humidity) alarms (built into temperature and humidity controller)
●
Specimen power supply control terminal Chamber door switch
● ●
11
OPTIONS UTILITY
TEST SAMPLE SETTING
OBSERVATION
Power cable
Shelf, shelf bracket
Viewing window
・ 2.5 m ・5 m ・ 10m
Equivalent to standard accessory.
Used for observation of the specimens inside the chamber. Dimensions: W340×H440 mm
*The chamber does not come with a power cable.
Water purifier (WS-1) Water purifier with reverse osmosis membrane. Produces approx 6.6L per hour (at primary water temp. +10℃). Heavy-duty shelf Used to hold heav y speci mens exceeding the load capacity of the standard shelf. Load capacity: 50kg (max. 2 shelves) *Standard for 1100L model
Water leak detection system and dew tray to catch dripping water are also available to detect and prevent water damages.
Portable tank
Additional cable port Provided in addition / replacement of the standard cable ports. ・ 50 mm diameter ・ 100 mm diameter
* Each cable por t is equipped with a silicone sponge rubber plug.
Used to refill the standard tank. *ARS, ARL only
NETWORK Interface Computer interface ・ RS-485 ・ GPIB ・ RS-232C Communication cables ・ RS-485 5m/ 10m/ 30m ・ RS-232C 1.5m/ 3m/ 6m ・ GPIB 2m/ 4m
Cable port rubber plug Prevents air leakage from the cable port.
12
SPECIMEN
TEMPERATURE INPUT OPTIONS ( TYPE T )
EXTRA OVERHEAT PROTECTOR
追加温度過昇防止器
試料温度入力
(JIS T )
LOGGING
EXTERNAL ALARM SIGNAL
TEST QUALITY
OPTION MODE
外部警報出力
TIME SIGNALS
タイムシグナル出力 Paperless recorder - portable No.3type No.4
Records temperature of each No.5 section POWER SUPPLY CONTROL such FOR asSPECIMEN the temperature inside the 試料電源制御出力 chamber. Data savingNo.1cycle: 5 sec. No.2 External recording media: TIME SIGNALS タイムシグナル出力 CF memory card (256MB) No.6 No.7 USB port Language support: ENG, JPN No.8 No.9 [Temperature type] ETHERNET No.10 Temperature range: −100 to +200℃ Number of inputs: Temperature 1 (5 more channels can be turned ON) [Temperature and humidity type] Temperature range: −100 to +200℃ Humidity range: 0 to 100%rh Number of inputs: Temperature 1 / Humidity 1 (4 more channels can be turned ON)
Temperature sensor terminal OVERCOOL PROTECTOR
Humidifier delay control
TerminalOPTION board for dry-bulb temperature sensor in the chamber.
To protect specimens from condensation, humidity control star ts after temperature reaches the set value.
温度過冷防止器
MODE
RECORDER OUTPUT
*ARL, ARS only
記録計用出力
OFF
CHAMBER TEMPERATURE (TYPE T) 槽内温度
(JIS T ) OPTION
MONITOR OUTPUT (1-5V DC LINEAR )
モニタ出力 (DC1-5V リニア ) OPTION
DC output terminal Outputs temperature, humidity, and temperature of the specimen from the test area. Relay contact output
SPECIMEN TEMPERATURE INPUT ( TYPE T )
Up to 8 contacts can be added to the EXTRA OVERHEAT standard 2 relay contacts (time signals). PROTECTOR 追加温度過昇防止器
試料温度入力
(JIS T )
EXTERNAL ALARM SIGNAL
OPTION MODE
外部警報出力
TIME SIGNALS
タイムシグナル出力 No.3
Temperature recorder (digital) Portable type −100 to +200℃ 6 dots
POWER SUPPLY CONTROL FOR SPECIMEN
No.4 No.5
試料電源制御出力
MODE
CHAMBER TEMPERATURE ( TYPE T)
TIME SIGNALS
Portable type −100 to +200℃ / 0 to 100%rh ETHERNET 6 dots
OPTION
記録計用出力
No.2
Temperature and humidity recorder (digital)
温度過冷防止器
RECORDER OUTPUT
No.1
タイムシグナル出力
OVERCOOL PROTECTOR
No.6 No.7 No.8
槽内温度
(JIS T ) OPTION
No.9 No.10
MONITOR OUTPUT (1-5V DC LINEAR )
モニタ出力 ( DC1-5V リニア ) OPTION
13
OFF
OPTIONS SAFETY
DOCUMENTS
Additional overheat protector
Emergency stop switch
Operation manual
Additional preventive measures can be taken for excessive temperature rise in the chamber, in addition to the standard equipped overheat protector.
Stops the chamber immediately.
・ CD ・ Booklet Reports & certificates
Overcool protector If the temperature inside the chamber decreases excessively, the chamber stops operating to prevent the specimens from being damaged. EXTRA OVERHEAT PROTECTOR
200V AC, 220V AC spec. 380V AC, 400V AC spec.
Trouble buzzer If a trouble occurs, the buzzer will alert you of the situation.
追加温度過昇防止器
L ALARM SIGNAL
OPTION
・ Testing and inspection report ・ Test data ・ Temperature (& humidity) uniformity measurement ・ Calibration report ・ Calibration certificate ・ Traceability system chart ・ Traceability certificate
Rotating signal lamp
MODE
警報出力
SIGNALS
グナル出力 No.3 No.4 No.5
The lamp lights up when alarm triggers. (Available in red or yellow)
OVERCOOL PROTECTOR 温度過冷防止器 OPTION MODE
RECORDER OUTPUT 記録計用出力
OFF
CHAMBER TEMPERATURE ( TYPE T)
No.6 No.7 No.8 No.9
SPECIMEN TEMPERATURE INPUT No.10 ( TYPE T ) 試料温度入力
(JIS T )
External alarm terminal 槽内温度
(JIS T )
If the safety device of the chamber is OPTION activated, the external alarm terminal will notify it to a remote point. EXTRA OVERHEAT MONITOR OUTPUT (1-5V DC LINEAR )
モニタ出力 ( DC1-5V リニア )
EXTERNAL ALARM OPTION SIGNAL
PROTECTOR
追加温度過昇防止器 OPTION MODE
外部警報出力
Safety precautions Do not use specimens which are explosive or flammable, or which contain such substances. To do so could be hazardous, as this may lead to fire or explosion. ●
●
TIME SIGNALS
タイムシグナル出力 No.3 No.4
ER SUPPLY CONTROL SPECIMEN
No.5
電源制御出力
OPTION
CHAMBER TEMPERATURE ( TYPE T )
ME SIGNALS
No.6 No.7 No.8
●
Do not use living organisms or items that exceed the allowable heat load as a specimen. Be sure to read the operation manual before operation. OFF
Please contact us for non-standard specification.
槽内温度
(JIS T )
Safety precautions
OPTION
No.9 No.10
●
MODE
記録計用出力
No.2
ETHERNET
温度過冷防止器
RECORDER OUTPUT
No.1
シグナル出力
OVERCOOL PROTECTOR
Do not place corrosive materials in the chamber. If corrosive substances or liquid is used, the life of the unit may be significantly shortened specifically because of the corrosion of stainless steel, resin and silicone materials.
MONITOR OUTPUT (1-5V DC LINEAR ) モニタ出力 ( DC1-5V リニア ) OPTION
Do not use specimens which are explosive or flammable, or which contain such substances. To do so could be hazardous, as this may lead to fire or explosion. ●
●
●
●
Do not place corrosive materials in the chamber. If corrosive substances or liquid is used, the life of the unit may be significantly shortened specifically because of the corrosion of stainless steel, resin and silicone materials. Do not use living organisms or items that exceed the allowable heat load as a specimen. Be sure to read the operation manual before operation.
Please contact us for non-standard specification.
14
http://www.espec.co.jp/english
Head Office 3-5-6, Tenjinbashi, Kita-ku, Osaka 530-8550, Japan Tel : 81-6-6358-4741 Fax : 81-6-6358-5500
ESPEC NORTH AMERICA, INC. Tel : 1-616-896-6100 Fax : 1-616-896-6150 ESPEC EUROPE GmbH Tel : 49-89-1893-9630 Fax : 49-89-1893-96379 ESPEC ENVIRONMENTAL EQUIPMENT (SHANGHAI) CO., LTD. Head Office Tel : 86-21-51036677 Fax : 86-21-63372237 BEIJING Branch Tel : 86-10-64627025 Fax : 86-10-64627036 TIANJIN Branch Tel : 86-22-26210366 Fax : 86-22-26282186 GUANGZHOU Branch Tel : 86-20-83317826 Fax : 86-20-83317825 SHENZHEN Branch Tel : 86-755-83674422 Fax : 86-755-83674228 SUZHOU Branch Tel : 86-512-68028890 Fax : 86-512-68028860 ESPEC TEST TECHNOLOGY (SHANGHAI) CO., LTD. Tel : 86-21-68798008 Fax : 86-21-68798088 ESPEC SOUTH EAST ASIA SDN. BHD. Tel : 60-3-8945-1377 Fax : 60-3-8945-1287
Quality Management System Assessed and Registered ESPEC CORP. has been assessed by and registered in the Quality Management System based on the International Standard ISO 9001:2008 (JIS Q 9001:2008) through the Japanese Standards Association (JSA). *Registration : ESPEC CORP. (Overseas subsidiaries not included) ●
TS3E27C03 (The contents of this catalog is as of March, 2015.)
●
Environmental Management System Assessed and Registered ESPEC CORP.
Specifications are subject to change without notice due to design improvements.
Corporate names and trade names mentioned in this catalog are trademarks or registered trademarks.