Preview only show first 10 pages with watermark. For full document please download

Head Office 3-5-6, Tenjinbashi, Kita-ku, Osaka 530-8550, Japan

   EMBED


Share

Transcript

Environmental Stress Chamber AR series CAT.NO.E14141 Advanced reliability Environmental Stress Chambers AR series has big allowable heat loads generated by the specimen, and achieves improved temperature change rate in an expanded temperature and humidity range. The new N-instrumentation allows AR series chambers to support easy-to-use networking system. ESPEC offers two temperature control ranges: −75℃ to +180℃ or −45℃ to +180℃, with or without humidity control (10 to 98%rh). These models incorporate the most desirable features in temperature and humidity chambers. ARS−0220 1 ARS−1100 *Viewing window is optional. Characteristics Superior temperature heating and cooling control at 3℃ /min. with specimen load Te mp e r at u re he at i ng a nd c o ol i ng performance at 4 to 6℃ /min. (no load), and can handle temperature cycle tests at 3℃ /min. (with load*) * ARS-1100 specimen: aluminum 38kg (including shelf 12kg) Highly uniform temperature distribution Temperature change rate Model Heat up (K/min.) Pull down (K/min.) ARL/ARU −0680 6.3 4.8 ARL/ARU −1100 4.7 4.4 ARS/ARG−0220 6.0 5.2 ARS/ARG−0390 5.0 4.0 ARS/ARG−0680 6.0 4.2 ARS/ARG−1100 4.7 4.1 *At ambient temperature, +20℃ no specimen. Temperature & Humidity Control Range Highly uniform temperature distribution minimizes variations in test results. (ambient temperature at +20℃ with no load) 100 90 80 Relative 70 Humidity 60 (%rh) 50 40 30 20 10 0 Reduced temperature and humidity stabilization time Temperature and humidity stabilization time is greatly reduced by minimizing hunting as the chamber approaches setpoint. (under testing operation from RT to 85℃ /85% rh). Wider control range for temperature and humidity Feat u res a w ider cont rol r a nge of temperature and humidity, including stable control at 95℃ /98% rh. Meets international standards Desig ned to comply with major environmental test standards such as IEC60068-2, or ISO16750-4 (5.3). (Refer to compatible test standards) International safety standard compliance Complies with Safety of Machinery (ISO 12100), Low Voltage (IEC 60204), EMC (IEC 61000-6-2, IEC 61000-6-4). 98 ARS・ARL 10 20 30 40 50 60 70 Temperature (℃) 80 90 100 95 *Continuous operation at or below +40℃ is limited because of frost formation on the cooler and dehumidifier. ● Compatible Test Standards Cold ・IEC60068-2-1: Dry heat ・IEC60068-2-2: Damp heat, steady state ・IEC60068-2-3: PR・PL・PSL ・IEC60068-2-14 Nb: Change of temperature with specified rate of change * Composite temperature/ humidity ・IEC60068-2-38: cyclic test * Damp heat, steady state ・IEC60068-2-78: Temperature cycling ・ISO16750-4 5.3: 2 Characteristics Supports heat loads up to 4500W* (During temperature testing) Supports electrically-charged specimens, and can compensate up to 4500W of heat load during temperature testing, depending on the chamber model (500W du r i ng t empe r at u re a nd hu m id it y testing). * Test area temperature:+20℃ User-friendly features Standard features include cable ports on both sides which allow free access of the test area. Antirust and oil proof 18-8 Cr-Ni stainless steel plate is used as external panels. It is possible to select water supply via water tank or direct water coupling alliteratively all the time. Cable ports on both walls Chamber restricted to lock the door It is now possible to lock the chamber door to prevent accidental operation of the chamber during testing. The handle part design has also been improved so the door closing is easier and safer. Water tank 3 Key New refrigeration circuit and condenser filter improves reliability Thanks to newly designed refrigeration circuit, reliability is improved. And further more condenser filter, prevents a condenser fan from clogging becomes standard equipment. Controller N-instrumentation N-instrumentation equipped with a color LCD touch panel Interior light Wide 7-inch screen with LED backlight is clearer and provides faster display speed. Interior light button It is able to switch ON/OFF from the interior light button any time. Information button Touch navigation When there are some things need to be notified to the operator, information button will alart to the operator. By pressi ng the but ton, you will f i nd notifications such as "Check Humidity Tray". Touch icon to show navigation bar. Application of USB MEMORY Continous record test data Data transfer Copy test program USB memory port Trend graph output on USB memory Trend graphs can be displayed on the web application or downloaded on USB m e m o r y. I t i s a l s o p o s s i b l e t o continuously register data on USB memory if numerous data records are needed. N-instrumentation Display TFT Color LCD (7.0inch) Operating mode Constant operation, Program operation, Remote operation, Stop Setting range Constant setup: 3 patterns Setting range: Temp.: −80.0℃ to +185.0℃, 0.1℃ unit (ARS, ARG) Temp.: −50.0℃ to +185.0℃, 0.1℃ unit (ARL, ARU) Humidity: 0 to 100% rh, 1% unit (ARS, ARL) ● Program setup: 40 patterns (99 steps) Setting range: Temp.: −80.0℃ to +185.0℃, 0.1℃ unit (ARS, ARG) −50.0℃ to +185.0℃, 0.1℃ unit (ARL, ARU) Humidity: 0 to 100% rh, 1% unit Time: 0 hour and 1 min. to 9999 hours and 59 min. 1 min. unit Language Japanese, English, Chinese (simplified, traditional), Korean Interface USB 2.0 standard compliant (A-type connector) External memory function Write sampling data, Read/ Write program, Backtrace output, Add-on/system updates Network function Interface: Ethernet port (100base-TX) Web function Monitoring, setting, operation, Data Record Function, maintenance setting, email alert Browser Windows Internet Explorer10 ● 4 Network Remote monitoring and control thanks to a Web application Remote monitoring and control (Ethernet connection) A unique web application allows the u s e r t o mo n it or t he ch a mb e r, s e t programs, and start and stop operation from a PC connected to the chamber Ethernet port (LAN’s port). No software required, the chamber can be accessed and cont rolled f rom PC via a web browser (Smartphone, tablets and the like can also be used). Wireless connection and multiple units connection are also possible. Image Login information Chamber monitor Constant Mode/ Program Setup Run/ Stop Device configuration Administrator ○ ○ ○ ○ Operator ○ ○ ○ × User ○ × × × Privileges Screen ○= available; ×= Not available ● Program editing ● Graph display Email alert When an alarm is triggered, an e-mail is sent to the registered PC or mobile address. A notification can also be sent at the time of test completion. *Requires an intranet environment capable of sending emails. Multilingual display The language available for the Web application (Japanese/ English/ Simplified Chinese/ Traditional Chinese/ Korean) can be changed without affecting the N-instrumentation language display. Email alert Ethernet PC PC Intranet (company LAN) 携帯電話 スマートフォン Mail server AR series 5 Program copy and computer editing Mobile phone Smartphone Environmental Stress Chamber タブレットコントローラー (オプション) Ethernet Network PC Intranet (company LAN) Mail server AR series Mobile phone Smartphone En Stre Copy and reproduce testing Program copy and computer editing Thanks to the USB memory you can copy the same test program in multiple chambers, provided that they have the Copy same operat ion range. No need to program each chamber, just connect the (別売) 2015年3月対応予定 集中管理システム :Web統合管理システム) USB and the test can(旧 start. 100台までの試験器の状態を1画面で確認することができる 集中管理システムに接続可能です。 Download edit programs online Edit エスペック ネットワーク 検索 Via the Pattern Manager Lite software installed 事務棟 on your PC, edit programs試験棟 according to your testing needs, and ● Test Navi Ethernet upload them with a USB. (http://www.test-navi.com/eng/index.html) Ethernet This website provides practical knowledge on environmental testing クライアントPC イントラネット Edit programs Through our online website Test Navi, dedicated to reliability Ethernet and testing information, you can find most of the recognized inter national standard, available for download. 集中管理システム Charge them as is on your USB memory, or edit them and transfer to your chamber. * Test Navi is a website dedicated to reliability testing information and technologies. http:// www.test-navi.com/eng/index.html that ESPEC has acquired through years of experience, as well as covering everything from the fundamentals to the latest information on Network environmental and reliability testing. Wi-Fi router ハイパワー恒温 (恒湿) 器 Product Registration EthernetMembership Website Product Registration Ethernet ネットワークアダプター Membership Website ・ Updates for chamber controller software PC 旧:RS-485 environmental test standards ・ Search forLANコンバーター プラチナスKシリーズ Tablet controller Environmental Test Smartphone AR series Standards For Pattern Manager LiteTest Environmental Test methods download The Pattern Manager Lite software allows you to edit programs for your chamber, view and edit data as graph, etc. The software can be downloaded from the Test Navi website. Standards For Pattern Manager Lite Test methods download 検索 エスペック オンライン ・ Download test profiles from a list of environmental test standards Web Integrated Network (Sold separately) Program copy and computer editing Maximum 100units of connected chambers and other peripherals necessary for environmental testing are manned via Internet. Product registration membership Website Office Lab Ethernet Ethernet Web integrated network system Intranet Client PC Ethernet Ethernet Download Pattern Manager and WEB Manager information. Product registration membership Website Download Pattern Manager and WEB Manager information. Download Copy Access to video Download 製品会員専用サイト パターンマネージャーの情報、 製品会員専用サイト ダウンロード WEBマネージャー情報のダウンロード AR series パターンマネージャーの情報、 Edit WEBマネージャー情報のダウンロード ダウンロード LAN converter 環境試験規格一覧 パターンマネージャーLite対応 Platinous K Series 環境試験規格一覧 試験条件プログラムパターンダウンロード パターンマネージャーLite対応 試験条件プログラムパターンダウンロード 試験規格プログラムパターン ファイルの活用方法 6 ARL −45 to +180℃・10 to 98%rh TEMPERATURE & HUMIDITY CHAMBER Model ARL−0680 Temp. & humid. Temp. performance *1 performance *1 System ARL−1100 Balanced Temperature & Humidity Control (BTHC) system −45 to +180℃ (−49 to +356℉) Temp. range ±0.3K Temp. fluctuation Temp. variation in space Heat up rate Temp. rate of change *2 Pull down rate 3.0K 6.3 K/min. 4.7 K/min. 4.8 K/min. 4.4 K/min. 4500 W Test area temperature: +20℃ Max. allowable heat load +10 to +95℃ / 10 to 98%rh Temp. & humid. range ±2.5%rh Humid. fluctuation 500 W Test area conditions: +85℃ /85%rh Max. allowable heat load Exterior material 18 Cr-stainless steel plate (Hairline finish) Test area material 18-8 Cr-Ni Stainless steel plate (BA finish) Insulation Foamed phenol, glass wool Nichrome strip wire heater (3 kW×2) Humidifier Sheathed heater Cooler Refrigeration unit Construction Heater Plate fin cooler and dehumidifier System Mechanical single-stage refrigeration system Refrigerator Refrigerator capacity Scroll-type compressor 3.0 kw 3.75 kw Expansion mechanism Electronic expansion valve Refrigerant R404A Air circulator Sirocco fan Interface Ethernet 100mm cable port (×2), specimen power supply control terminal, condenser filter, specimen temperature input terminal, time signal (×2), casters with levelling feet (×4) Fittings Capacity 680 L 1100 L Chamber total load resistance 80 kg 150 kg Inside dimensions mm (inch) *3 W850×H1000×D800 (W33.5×H39.4×D31.5) W1100×H1000×D1000 (W43.3×H39.4×D39.4) Outside dimensions mm (inch) *3 W1050×H1955×D1805 (W41.3×H77.0×D71.1) W1300×H1955×D2005 (W51.2×H77.0×D78.9) 510 kg 600 kg Utility requirements Weight 200V AC 3φ50/60Hz 53 A 56 A 220V AC 3φ60Hz 49 A 52 A 23 A 25 A 400V AC 3φ50Hz *5 22 A 23 A 61 dB 62 dB 32400 (7743) 39600 (9464) Power supply *4 380V AC 3φ50Hz Noise level *6 Exhaust heat quantity kJ/h (kcal/h) *1: *2: *3: *4: *5: *6: 7 0 to +40℃ (+32 to +104℉) / 75%rh max. Allowable ambient conditions At ambient temperature +20℃, no specimen. Performance shown above conforms to IEC 60068-3-5:2001 and IEC 60068-3-6:2001. Temperature rate of change in the temperature range excluding ±10% of max/min. temperature. Excluding protrusions. Power supply voltage fluctuation to be ±10% of rated value. Conforms to CE marking based on EU directives. Measurements are to be taken in an anechoic room at a height of 1.2m from the floor and a distance of 1m from the chamber front panel (ISO 1996-1:2003 _ A-weighted sound pressure level). ARS −75 to +180℃・10 to 98%rh TEMPERATURE & HUMIDITY CHAMBER Model ARS−0220 Temp. & humid. performance *1 Temp. performance *1 System ARS−0390 ARS−1100 −75 to +180℃ (−103 to +356℉) Temp. range ±0.3K Temp. fluctuation Temp. variation in space Heat up rate Temp. rate of change *2 Pull down rate 3.0K 6.0 K/min. 5.0 K/min. 6.0 K/min. 4.7K/min. 5.2 K/min. 4.0 K/min. 4.2 K/min. 4.1K/min. Max. allowable heat load Test area temperature: +20℃ 3000 W Humid. fluctuation Max. allowable heat load 4500 W +10 to +95℃ / 10 to 98%rh Temp. & humid. range ±2.5%rh Test area conditions: +25 to +95℃ /90%rh 350 W 300 W Test area conditions: +85℃ /85%rh 500 W Exterior material 18 Cr-stainless steel plate (Hairline finish) Test area material 18-8 Cr-Ni Stainless steel plate (BA finish) Insulation Foamed phenol, glass wool Heater Nichrome strip wire heater (1.75 kW×2) Humidifier (3 kW×2) Sheathed heater Cooler Refrigeration unit Construction ARS−0680 Balanced Temperature & Humidity Control (BTHC) system Plate fin cooler and dehumidifier System Mechanical cascade and compression refrigeration system Refrigerator Rotary compressor Scroll compressor Unit 1: 2.2 kw ×1, Unit 2: 2.2 kw ×1 Refrigerator capacity Expansion mechanism Unit 1: 3.0 kw ×1, Unit 2: 3.0 kw ×1 Unit 1: 3.75 kw ×1, Unit 2: 3.75 kw ×1 Electronic expansion valve Refrigerant R404A, R508A R404A, R23 Air circulator Sirocco fan Interface Ethernet 100mm cable port (×2), specimen power supply control terminal, condenser filter, specimen temperature input terminal, time signal (×2), casters with levelling feet (×4) Fittings Capacity 220 L Chamber total load resistance 390 L 680 L 1100 L 50 kg 80 kg 80 kg 150 kg Inside dimensions mm (inch) *3 W700×H800×D400 (W27.6×H31.5×D15.8) W700×H800×D700 (W27.6×H31.5×D27.6) W850×H1000×D800 (W33.5×H39.4×D31.5) W1100×H1000×D1000 (W43.3×H39.4×D39.4) Outside dimensions mm (inch) *3 W900×H1742×D1455 (W35.4×H68.6×D57.3) W900×H1742×D1705 (W35.4×H68.6×D67.1) W1050×H1955×D1805 (W41.3×H77.0×D71.1) W1300×H1955×D2005 (W51.2×H77.0×D78.9) 405 kg 615 kg 700 kg Utility requirements Weight 390 kg 200V AC 3φ50/60Hz 220V AC 3φ60Hz Power supply *4 380V AC 3φ50Hz 400V AC 3φ50Hz *5 Noise level *6 Exhaust heat quantity kJ/h (kcal/h) *1: *2: *3: *4: *5: *6: 0 to +40℃ (+32 to +104℉) / 75%rh max. Allowable ambient conditions ─ ─ 63 A 70 A 38 A *5 38 A *5 58 A 64 A 24 A *5 24 A *5 28 A 32 A 23 A 23 A 27 A 29 A 57 dB 58 dB 62 dB 63 dB 26600 (6357) 26600 (6357) 39600 (9464) 46800 (11185) At ambient temperature +20℃, no specimen. Performance shown above conforms to IEC 60068-3-5:2001 and IEC 60068-3-6:2001. Temperature rate of change in the temperature range excluding ±10% of max/min. temperature. Excluding protrusions. Power supply voltage fluctuation to be ±10% of rated value. Conforms to CE marking based on EU directives. Measurements are to be taken in an anechoic room at a height of 1.2m from the floor and a distance of 1m from the chamber front panel (ISO 1996-1:2003 _ A-weighted sound pressure level). 8 ARU −45 to +180℃ TEMPERATURE CHAMBER Model ARU−0680 Temp. performance *1 System −45 to +180℃ (−49 to +356℉) Temp. range ±0.3 K Temp. fluctuation Temp. variation in space Temp. rate of change *2 3.0 K Heat up rate 6.3 K/min. 4.7 K/min. Pull down rate 4.8 K/min. 4.4 K/min. 4500 W Test area temperature: +20℃ Max. allowable heat load Exterior material 18 Cr-stainless steel plate (Hairline finish) Test area material 18-8 Cr-Ni Stainless steel plate (BA finish) Foamed phenol, glass wool Heater Nichrome strip wire heater (3kW ×2) Cooler Plate fin cooler Refrigeration unit Construction Insulation System Mechanical single-stage refrigeration system Refrigerator Scroll-type compressor Refrigerator capacity 3.0 kw 3.75 kw Expansion mechanism Electronic expansion valve Refrigerant R404A Air circulator Sirocco fan Interface Ethernet 100mm cable port (×2), specimen power supply control terminal, condenser filter, specimen temperature input terminal, time signal (×2), casters with levelling feet (×4) Fittings Capacity Chamber total load resistance Inside dimensions mm (inch) *3 Outside dimensions mm (inch) *3 Utility requirements Weight 1100 L 80 kg 150 kg W850×H1000×D800 (W33.5×H39.4×D31.5) W1100×H1000×D1000 (W43.3×H39.4×D39.4) W1050×H1955×D1805 (W41.3×H77.0×D71.1) W1300×H1955×D2005 (W51.2×H77.0×D78.9) 505 kg 595 kg 0 to +40℃ (+32 to +104℉) / 75%rh max. 200V AC 3φ50/60Hz 53 A 56 A 220V AC 3φ60Hz 49 A 52 A 23 A 25 A 400V AC 3φ50Hz *5 22 A 23 A Power supply *4 380V AC 3φ50Hz Exhaust heat quantity kJ/h (kcal/h) 9 680 L Allowable ambient conditions Noise level *6 *1: *2: *3: *4: *5: *6: ARU−1100 Balanced Temperature Control (BTC) system 61 dB 62 dB 32400 (7743) 39600 (9464) At ambient temperature +20℃, no specimen. Performance shown above conforms to IEC 60068-3-5:2001. Temperature rate of change in the temperature range excluding ±10% of max/min. temperature. Excluding protrusions. Power supply voltage fluctuation to be ±10% of rated value. Conforms to CE marking based on EU directives. Measurements are to be taken in an anechoic room at a height of 1.2m from the floor and a distance of 1m from the chamber front panel (ISO 1996-1:2003 _ A-weighted sound pressure level). ARG −75 to +180℃ TEMPERATURE CHAMBER Model ARG−0220 ARG−0390 Temp. performance *1 System ARG−1100 −75 to +180℃ (−103 to +356℉) Temp. range ±0.3 K Temp. fluctuation Temp. variation in space Temp. rate of change *2 3.0 K Heat up rate 6.0 K/min. 5.0 K/min. 6.0 K/min. 4.7K/min. Pull down rate 5.2 K/min. 4.0 K/min. 4.2 K/min. 4.1K/min. Test area temperature: +20℃ Max. allowable heat load 3000 W 4500 W Exterior material 18 Cr-stainless steel plate (Hairline finish) Test area material 18-8 Cr-Ni Stainless steel plate (BA finish) Insulation Foamed phenol, glass wool Nichrome strip wire heater Heater (1.75 kW×2) (3 kW×2) Cooler Refrigeration unit Construction ARG−0680 Balanced Temperature Control (BTC) system Plate fin cooler System Mechanical cascade refrigeration system Refrigerator Scroll-type compressor Unit 1: 2.2 kw ×1, Unit 2: 2.2 kw ×1 Refrigerator capacity Expansion mechanism Unit 1: 3.0 kw ×1, Unit 2: 3.0 kw ×1 Unit 1: 3.75 kw ×1, Unit 2: 3.75 kw ×1 Electronic expansion valve Refrigerant R404A, R508A R404A, R23 Air circulator Sirocco fan Interface Ethernet 100mm cable port (×2), specimen power supply control terminal, condenser filter, specimen temperature input terminal, time signal (×2), casters with levelling feet (×4) Fittings Capacity 220 L 390 L 680 L 1100 L Chamber total load resistance 50 kg 80 kg 80 kg 150 kg Inside dimensions mm (inch) *3 W700×H800×D400 (W27.6×H31.5×D15.8) W700×H800×D700 (W27.6×H31.5×D27.6) W850×H1000×D800 (W33.5×H39.4×D31.5) W1100×H1000×D1000 (W43.3×H39.4×D39.4) Outside dimensions mm (inch) *3 W900×H1742×D1455 (W35.4×H68.6×D57.3) W900×H1742×D1705 (W35.4×H68.6×D67.1) W1050×H1955×D1805 (W41.3×H77.0×D71.1) W1300×H1955×D2005 (W51.2×H77.0×D78.9) 385 kg 400 kg 615 kg 700 kg Utility requirements Weight 200V AC 3φ50/60Hz 220V AC 3φ60Hz Power supply *4 380V AC 3φ50Hz 400V AC 3φ50Hz ─ ─ 63 A 70 A 38 A 38 A *5 58 A 64 A 24 A *5 28 A 32 A *5 24 A *5 *5 Noise level *6 Exhaust heat quantity kJ/h (kcal/h) *1: *2: *3: *4: *5: *6: 0 to +40℃ (+32 to +104℉) / 75%rh max. Allowable ambient conditions 23 A 23 A 27 A 29 A 57 dB 58 dB 62 dB 63 dB 26600 (6357) 26600 (6357) 39600 (9464) 46800 (11185) At ambient temperature +20℃, no specimen. Performance shown above conforms to IEC 60068-3-5:2001. Temperature rate of change in the temperature range excluding ±10% of max/min. temperature. Excluding protrusions. Power supply voltage fluctuation to be ±10% of rated value. Conforms to CE marking based on EU directives. Measurements are to be taken in an anechoic room at a height of 1.2m from the floor and a distance of 1m from the chamber front panel (ISO 1996-1:2003 _ A-weighted sound pressure level). 10 ACCESSORIES SAFETY DEVICES Cable port rubber plug (φ100 mm) 2 each ● Shelf brackets stainless steel plate (18-8 Cr-Ni stainless steel) 1 set ● Shelf stainless steel wire (18-8 Cr-Ni stainless steel) Door key ● Cartridge fuse (Class B, 250 V 0.4 A, 5 A, 8 A) 1 ● 2 ● 1 each ● Wet-bulb wick (ARL, ARS) ● ● ● 1 box (24 wicks) ● Control circuit overcurrent protection Control circuit short circuit protection cartridge fuse System error Reverse-prevention relay Thermal fuse Temperature switch for air circulator Air circulator short circuit protection Ambient temperature input burn-out detection circuit Dry-bulb temperature input burn-out detection circuit Specimen temperature input burn-out detection circuit (only when using specimen temperature control) ● Specimen temperature measuring thermocouple (type T, 3m) 1 ● Specimen temperature input connector ● ● ● ● ● 1 ● Operation manual 1 ● Condenser fan short circuit protection Condenser fan overload protection Refrigerator temperature sensor burned detect circuit Refrigerator short circuit protection Refrigerator overcurrent protection Refrigerator discharge pipe temperature switch (0680/1100) Refrigerator high (low) pressure switch Refrigerator frost detection cicuit (0680/1100) Refrigerator circuit temperature range over Refrigerator frost trouble detection temperature switch (ARS-0680/1100, ARG-0680/1100) ● ● ● SHELVES SIZE AND LOAD RESISTANCE Model 0220 0390 0680 1100 Shelf size (mm) W667 D350 W667 D650 W817 D750 W1067 D950 Shelf weight 2 kg 3 kg 6 kg 12 kg Shelf load capacity (evenly distributed load) 30 kg 30 kg 40 kg 50 kg Shelf support max. load (Including shelf weight) 50 kg 80 kg 80 kg 100 kg ● ● ● ● ● ● ● Refrigerator discharge pipe temperature trouble detection circuit (ARS, ARG) ● Heater (humidifier) leak current protection ● Wet bulb temperature input burnout detection circuit (ARL, ARS) ● Humidifier boil-dry protector (ARL, ARS) Humidifier water level detector (ARL, ARS) Water tank empty switch (ARL, ARS) Water tank low level switch (ARL, ARS) Dry wick detection (ARL, ARS) Overheat protector High deviation temperature alarm (built into temperature and humidity controller) ● ● ● ● ● ● ● High/ low absolute temperature (humidity) alarms (built into temperature and humidity controller) ● Specimen power supply control terminal Chamber door switch ● ● 11 OPTIONS UTILITY TEST SAMPLE SETTING OBSERVATION Power cable Shelf, shelf bracket Viewing window ・ 2.5 m ・5 m ・ 10m Equivalent to standard accessory. Used for observation of the specimens inside the chamber. Dimensions: W340×H440 mm *The chamber does not come with a power cable. Water purifier (WS-1) Water purifier with reverse osmosis membrane. Produces approx 6.6L per hour (at primary water temp. +10℃). Heavy-duty shelf Used to hold heav y speci mens exceeding the load capacity of the standard shelf. Load capacity: 50kg (max. 2 shelves) *Standard for 1100L model Water leak detection system and dew tray to catch dripping water are also available to detect and prevent water damages. Portable tank Additional cable port Provided in addition / replacement of the standard cable ports. ・ 50 mm diameter ・ 100 mm diameter * Each cable por t is equipped with a silicone sponge rubber plug. Used to refill the standard tank. *ARS, ARL only NETWORK Interface Computer interface ・ RS-485 ・ GPIB ・ RS-232C Communication cables ・ RS-485 5m/ 10m/ 30m ・ RS-232C 1.5m/ 3m/ 6m ・ GPIB 2m/ 4m Cable port rubber plug Prevents air leakage from the cable port. 12 SPECIMEN TEMPERATURE INPUT OPTIONS ( TYPE T ) EXTRA OVERHEAT PROTECTOR 追加温度過昇防止器 試料温度入力 (JIS T ) LOGGING EXTERNAL ALARM SIGNAL TEST QUALITY OPTION MODE 外部警報出力 TIME SIGNALS タイムシグナル出力 Paperless recorder - portable No.3type No.4 Records temperature of each No.5 section POWER SUPPLY CONTROL such FOR asSPECIMEN the temperature inside the 試料電源制御出力 chamber. Data savingNo.1cycle: 5 sec. No.2 External recording media: TIME SIGNALS タイムシグナル出力 CF memory card (256MB) No.6 No.7 USB port Language support: ENG, JPN No.8 No.9 [Temperature type] ETHERNET No.10 Temperature range: −100 to +200℃ Number of inputs: Temperature 1 (5 more channels can be turned ON) [Temperature and humidity type] Temperature range: −100 to +200℃ Humidity range: 0 to 100%rh Number of inputs: Temperature 1 / Humidity 1 (4 more channels can be turned ON) Temperature sensor terminal OVERCOOL PROTECTOR Humidifier delay control TerminalOPTION board for dry-bulb temperature sensor in the chamber. To protect specimens from condensation, humidity control star ts after temperature reaches the set value. 温度過冷防止器 MODE RECORDER OUTPUT *ARL, ARS only 記録計用出力 OFF CHAMBER TEMPERATURE (TYPE T) 槽内温度 (JIS T ) OPTION MONITOR OUTPUT (1-5V DC LINEAR ) モニタ出力 (DC1-5V リニア ) OPTION DC output terminal Outputs temperature, humidity, and temperature of the specimen from the test area. Relay contact output SPECIMEN TEMPERATURE INPUT ( TYPE T ) Up to 8 contacts can be added to the EXTRA OVERHEAT standard 2 relay contacts (time signals). PROTECTOR 追加温度過昇防止器 試料温度入力 (JIS T ) EXTERNAL ALARM SIGNAL OPTION MODE 外部警報出力 TIME SIGNALS タイムシグナル出力 No.3 Temperature recorder (digital) Portable type −100 to +200℃ 6 dots POWER SUPPLY CONTROL FOR SPECIMEN No.4 No.5 試料電源制御出力 MODE CHAMBER TEMPERATURE ( TYPE T) TIME SIGNALS Portable type −100 to +200℃ / 0 to 100%rh ETHERNET 6 dots OPTION 記録計用出力 No.2 Temperature and humidity recorder (digital) 温度過冷防止器 RECORDER OUTPUT No.1 タイムシグナル出力 OVERCOOL PROTECTOR No.6 No.7 No.8 槽内温度 (JIS T ) OPTION No.9 No.10 MONITOR OUTPUT (1-5V DC LINEAR ) モニタ出力 ( DC1-5V リニア ) OPTION 13 OFF OPTIONS SAFETY DOCUMENTS Additional overheat protector Emergency stop switch Operation manual Additional preventive measures can be taken for excessive temperature rise in the chamber, in addition to the standard equipped overheat protector. Stops the chamber immediately. ・ CD ・ Booklet Reports & certificates Overcool protector If the temperature inside the chamber decreases excessively, the chamber stops operating to prevent the specimens from being damaged. EXTRA OVERHEAT PROTECTOR 200V AC, 220V AC spec. 380V AC, 400V AC spec. Trouble buzzer If a trouble occurs, the buzzer will alert you of the situation. 追加温度過昇防止器 L ALARM SIGNAL OPTION ・ Testing and inspection report ・ Test data ・ Temperature (& humidity) uniformity measurement ・ Calibration report ・ Calibration certificate ・ Traceability system chart ・ Traceability certificate Rotating signal lamp MODE 警報出力 SIGNALS グナル出力 No.3 No.4 No.5 The lamp lights up when alarm triggers. (Available in red or yellow) OVERCOOL PROTECTOR 温度過冷防止器 OPTION MODE RECORDER OUTPUT 記録計用出力 OFF CHAMBER TEMPERATURE ( TYPE T) No.6 No.7 No.8 No.9 SPECIMEN TEMPERATURE INPUT No.10 ( TYPE T ) 試料温度入力 (JIS T ) External alarm terminal 槽内温度 (JIS T ) If the safety device of the chamber is OPTION activated, the external alarm terminal will notify it to a remote point. EXTRA OVERHEAT MONITOR OUTPUT (1-5V DC LINEAR ) モニタ出力 ( DC1-5V リニア ) EXTERNAL ALARM OPTION SIGNAL PROTECTOR 追加温度過昇防止器 OPTION MODE 外部警報出力 Safety precautions Do not use specimens which are explosive or flammable, or which contain such substances.  To do so could be hazardous, as this may lead to fire or explosion. ● ● TIME SIGNALS タイムシグナル出力 No.3 No.4 ER SUPPLY CONTROL SPECIMEN No.5 電源制御出力 OPTION CHAMBER TEMPERATURE ( TYPE T ) ME SIGNALS No.6 No.7 No.8 ● Do not use living organisms or items that exceed the allowable heat load as a specimen. Be sure to read the operation manual before operation. OFF Please contact us for non-standard specification. 槽内温度 (JIS T ) Safety precautions OPTION No.9 No.10 ● MODE 記録計用出力 No.2 ETHERNET 温度過冷防止器 RECORDER OUTPUT No.1 シグナル出力 OVERCOOL PROTECTOR Do not place corrosive materials in the chamber. If corrosive substances or liquid is used, the life of the unit may be significantly shortened specifically because of the corrosion of stainless steel, resin and silicone materials. MONITOR OUTPUT (1-5V DC LINEAR ) モニタ出力 ( DC1-5V リニア ) OPTION Do not use specimens which are explosive or flammable, or which contain such substances.  To do so could be hazardous, as this may lead to fire or explosion. ● ● ● ● Do not place corrosive materials in the chamber. If corrosive substances or liquid is used, the life of the unit may be significantly shortened specifically because of the corrosion of stainless steel, resin and silicone materials. Do not use living organisms or items that exceed the allowable heat load as a specimen. Be sure to read the operation manual before operation. Please contact us for non-standard specification. 14 http://www.espec.co.jp/english Head Office 3-5-6, Tenjinbashi, Kita-ku, Osaka 530-8550, Japan Tel : 81-6-6358-4741 Fax : 81-6-6358-5500 ESPEC NORTH AMERICA, INC. Tel : 1-616-896-6100 Fax : 1-616-896-6150 ESPEC EUROPE GmbH Tel : 49-89-1893-9630 Fax : 49-89-1893-96379 ESPEC ENVIRONMENTAL EQUIPMENT (SHANGHAI) CO., LTD. Head Office Tel : 86-21-51036677 Fax : 86-21-63372237 BEIJING Branch Tel : 86-10-64627025 Fax : 86-10-64627036 TIANJIN Branch Tel : 86-22-26210366 Fax : 86-22-26282186 GUANGZHOU Branch Tel : 86-20-83317826 Fax : 86-20-83317825 SHENZHEN Branch Tel : 86-755-83674422 Fax : 86-755-83674228 SUZHOU Branch Tel : 86-512-68028890 Fax : 86-512-68028860 ESPEC TEST TECHNOLOGY (SHANGHAI) CO., LTD. Tel : 86-21-68798008 Fax : 86-21-68798088 ESPEC SOUTH EAST ASIA SDN. BHD. Tel : 60-3-8945-1377 Fax : 60-3-8945-1287 Quality Management System Assessed and Registered ESPEC CORP. has been assessed by and registered in the Quality Management System based on the International Standard ISO 9001:2008 (JIS Q 9001:2008) through the Japanese Standards Association (JSA). *Registration : ESPEC CORP. (Overseas subsidiaries not included) ● TS3E27C03 (The contents of this catalog is as of March, 2015.) ● Environmental Management System Assessed and Registered ESPEC CORP. Specifications are subject to change without notice due to design improvements. Corporate names and trade names mentioned in this catalog are trademarks or registered trademarks.