Transcript
Healthcare Oxygen Concentrator 3 Liter OPERATION MANUAL
HINOR MEDICAL INDUSTRY COMPANY LIMTED Add.: VIKING HOUSE, 71 PRINCESS ROAD, URMSTON, MANCHESTER, M41 5ST E-mail:
[email protected] Service Tel:0870 712 0202
Instruction Guide For your safety and the performance of the unit, please read this entire guide before using your 3L Healthcare Oxygen Concentrator.
1
NOTES
concentrator. 9. When used in vehicle, the unit can be started up only after engine of the vehicle runs smoothly.
1. Do not turn the unit upside down or lay it down.
10. When the unit is operating, do not open the cabinet. If for quality
2. This oxygen concentrator can not be used in medical therapy, or used
issues, please refer to “TROUBLESHOOTING”, and contact the
for life saving or operations.
service facilities or the manufacturer immediately.
3. Turn off the power when no one breathes oxygen.
11. To prevent product damage, do not attempt to operate the unit without
4. This oxygen concentrator is mainly used for breathing oxygen for family
the air filter or while the filter is still damp.
healthcare or when you are tied in driving in tourism, which can ease
12. For safety and the performance and life of the unit, generally, only the
fatigue and refresh yourself and restore consciousness. Generally
line cord and plug equipped by our company can be used.
speaking, it can not be used in oxygen therapy. 5. Oxygen causes rapid burning. Do not smoke while your oxygen
Special warning
concentrator is operating, or when you are near a person utilizing oxygen
To prevent power off or other accidents, it is quite
therapy. Do not use it within 1.6m of hot, sparking objects or sources of
necessary for the oxygen provider having other spare
flame.
oxygen equipments on hand (eg. oxygen bottle, oxygen
6. The power supply attached to the concentrator should have enough
bag, etc.).
capacitance. 7. Make sure the voltage you use must meet the specifications of the product. 8. Turn off the power and remove the plug when on one uses the
APPLICATIONS Used for general oxygen equipments and providing oxygen for healthcare. 2
oil-free mirco-compressor to compress air to a certain pressure, the air
FUNCTIONS AND FEATURES Hinor Oxygen concentrator is a High-Tech product, combining advanced oil-free lubricating compression technology and gas separation technology. By utilizing the PSA gas separation technology to separate oxygen from air, and make its concentration around 90%. The customers
through high-quality imported sieve beds to be adsorbed and desorbed under ambient temperature, and then “create” qualified oxygen for demanders. Main parts: micro-compressor, sieve beds, PCB, air filter, adapter, humidifier bottle, etc..
breath oxygen from the concentrator, which can ease fatigue causing by hard working and can reduce uncomfortableness for lack of oxygen. This oxygen concentrator can run continuously with reliability. It is easy to operate and use. Low noise, long life, low power consumption, low cost. It only takes around 1KWh after continuously running for 10hrs. It is quite suitable for taking it as a family healthcare equipment. In addition, for its small size and light weight, the unit can be used as a movable oxygen equipment when you are in tourism.
HOW TO MAKE OXYGEN? MAIN PARTS OF YOUR CONCENTRATOR How to make oxygen? We use a high-efficiency energy-saving 3
Parts schematics 3
4
5
2
6
1
1. OXYGEN OUTLET
2. ATOMIZING OUTLET
3. LCD
4. TIME
5. ON/OFF
6. TIMER
4
SPECIFICATIONS
Operating
Item
Specification
1. Fill the humidifier bottle with purified water (or distilled water) within the
Oxygen Concentration
90±3% (altitude: below 2000m)
upper&lower limits. Secure the cap to the bottle. Locate the humidifier
Oxygen Pressure
40~60KPa
Sound
≤45 dB(A)
Ambient Temp.
5~40℃
Storage Temp.
-20~60℃
Ambient Humidity
≤80%RH
Storage Humidity
≤90%RH
Size (Length X Width X Height)
310×220×364(mm)
Unit Weight
9.2Kg
Atomizing Pressure
135±10(KPa)
bottle onto the humidifier bottle seat.
2. Attach one end of the oxygen tubing to oxygen outlet on the concentrator, and the other end to oxygen inlet on the humidifier bottle.
SET UP AND OPERATE Open package and check After open the package, before operate the unit, please read this instruction guide first, and then check the appearance of the unit, make
Insert the nasal cannula onto the oxygen outlet on the humidifier bottle.
Oxygen outlet,
Here connected with
connect with the
oxygen outlet on
nasal cannula.
the concentrator.
sure the attached accessories can completely meet the packing list.
5
3. Connect power source to the concentrator, press
button on the
fitting, regulate the atomizing setting button to the optimum performance.
panel, turn on the power switch, it starts to run. If you want to set a operating time, press
button after the unit starts running. Turn on this
button, the number on the display with unit of minute. Users can adjust the time shown on the display. In addition, button
is for accumulated
time. When you press this button, it will show the total time you use the
6. Remove the nasal cannula and turn off the power when you finish
concentrator. The unit of the number on the display is hour.
breathing.
4. Insert the nasal cannula in your nose to breath, regulate the oxygen setting button to the flow you want. (1) The tubing through the center of the humidifier bottle should bubble. The oxygen outlet should have air out.
MAINTENANCE
(2) Users put on the nasal cannula as this figure shows, and you can
1. Store your concentrator in a place of dry and free of any dust or any
breathe oxygen soon. (You can set the time and flow per your needs.)
corrosive gas. 2. Before clean up dust on the concentrator cabinet, you must have the power cord removed from the electrical outlet. 3. If your physician has prescribed humidification, clean your humidifier
5. The concentrator can also function of
atomizing. You can put the
medical into the nebulizer, plug the nebulizer tubing onto the air atomizing
bottle daily. Follow the instructions supplied by the manufacturer. If no cleaning instructions were supplied, follow these steps: 6
(1) Wash the humidifier bottle in a solution of hot water and dishwashing detergent.
4. The air filter on the concentrator should be cleaned periodically (we recommend to clean it once a week). To clean, follow these steps: (1) Remove the air filter located on the back of the concentrator. (2) Wash in a solution of warm water and dishwashing detergent.
(2) Soak the humidifier bottle in a solution of one part white vinegar to three parts hot water for 30 minutes. This solution acts as a germicidal agent. (3) Rinse thoroughly with warm water and towel dry. The air filter shuld be completely dry before reinstalling. 5. Do not clean the cabinet using water directly. Wipe the cabinet using a damp cloth with detergent, and then clean it utilizing a damp cloth without (3) Rinse thoroughly with hot water and refill with distilled water for use. Do not overfill, the water level should between 1/2~2/3 of the bottle. If you are not going to use the unit for a long time, please clean these accessory parts and store them properly.
detergent, finally, towel it dry using a dry cloth. 6. Do not reset the unit frequently. The intervals between resets should at least be 5 minutes. (Namely, the unit must have the air exhausted to avoid the air compressor operating with loading which will affect the life of the concentrator.)
7
WARRANTY 1. Within one year starting from date of shipment, our company will
TROUBLESHOOTING Symptom
maintain the unit free of charge if it can not run smoothly for quality issue
Appearance defects or easily wear parts are not covered by this
2. Other clauses unstated here will be performed per the National
Remedy
Power cord is
under the term that the users operate the concentrator properly.
warranty..
Causes
not inserted
Check the power cord, secure the
into outlet or
plug.
plug looses. Unit cannot be started.
Regulations for electrical equipments.
Voltage too low. Unit failed.
3. Beyond warranty, users need to contact our company for accessories. Fuse burnt out. Low flow
Add regulated power supply. Please contact service offices or the manufacturer. Turn off the power and replace the fuse with a same one. Check the nasal cannula for bent or pressed.
No flow or
Leakage on
Check all outside connections for
very low flow.
connections.
leakage.
Unit failed
Please contact service facilities or
inside.
the manufacturer.
8
PACKING LIST No.
1
Description
Oxygen concentrator
SEEKING USERS’ VIEWS QTY
Equipped or not? Yes
No
1 unit
□
□
User’s name Postal code
2
Air filter
2 pieces
□
□
3
Nasal cannula
1 set
□
□
date
4
Humidifier bottle
1 set
□
□
Provider
5
Instruction guide
1 piece
□
□
6
Nebulizer
1 piece
□
□
7
Nebulizer tubing
1 piece
□
□
8
Warranty card
1 piece
□
□
9
Headset
1 piece
□
□
Purchased
Address
Telephone
Model no.
Views (Suggestions):
Select accessories No.
1 2
Description An adapter can be used both for AC and DC. Portable bag
QTY
Equipped or not? Yes
No
1 piece
□
□
1 piece
□
□
Please send your views(suggestions) and requirements to our company per the address and postal code shown on the back cover of this guide.
9