Transcript
Technical Catalogue
Notus Heat Recovery Ventilator
Contents
About Impelair Who we are, what we do.
NOTUS Units..................................................... 3 Unit Specifications........................................... 4 Dimensions....................................................... 5 Performance Data............................................ 6 Components..................................................... 9 Accessories.................................................... 12
Impelair AS was established to serve the Heating, Ventilation and Air Conditioning (HVAC) market with innovative design, superior quality, advanced logistics and reliable services. Impelair AS aims to offer energy-efficient, easy-to-operate and service-free HVAC equipment for the market while maintaining premium quality. Impelair AS is located in the Aegean Free Zone in Izmir, Turkey. The Free Zone has more than 240 global companies taking advantage of the simplified customs and logistics procedures. The manufacturing processes involve high-tech CNC machines to ensure precise manufacturing quality and production plant efficiency. The equipment is manufactured on assembly and sub-assembly lines where quality control is carried out in line with both national and international standards. Every single unit manufactured is checked with electrical control equipment before packing to prevent any problems in the field. The HVAC market has been growing as an industry for the last 15 years. With the enhancement in building material technology and the new regulations for energy efficiency imposed by the authorities, the equipment technology is also changing to meet demand. At Impelair AS, we not only focus on today’s technologies but also on communicating our vision of what tomorrow’s needs will be. We are working in cooperation with the major component manufacturers, meaning we all benefit from the mutual innovations and knowhow. By applying the results of this work to our product range at Impelair AS, we create energyefficient products for buildings with a low energy profile.
2
Notus Units NOTUS units are designed as compact heat recovery ventilators to meet the increasing demand for energy efficiency by means of heat recovery and energy consumption for residential and commercial HVAC applications. The units are equipped with the latest technology components and IQ control system. Applying the latest developments in components, NOTUS units ensure very low specific fan power (SFP) values and high heat exchange efficiencies. With the standard IQ control and LCD control panel the user can select between different operational modes, independent 3 speed fan speed control, unbalanced ventilation, weekly timer, filter monitoring, free cooling by means of “By-pass Ventilation” and automatic fan speed setting with “Ventilation on Demand”.
Functions NOTUS units: • • • • •
Supply fresh air for indoors. Extract stale indoor air. Transfer heat between supply and exhaust air streams. Filters supply air. Reheats fresh air with hot water coils.
Energy Savings and Environmental Responsibility With their superior heat recovery potential, an average size NOTUS unit is capable of recovering approx. 15 kW of heat energy per hour in winter with nominal air flows. On an annual basis, it is possible to recover over 65000 kW of thermal energy in certain climatic conditions. To generate this thermal energy the atmosphere would be subject to 13000 kg of CO2 emissions with natural gas. At Impelair AS we encourage such benefits in order to preserve the natural heritage for future generations.
Advantages • • • • • • •
High thermal efficiency with Counterflow exchangers Low power consumption with RadiCal blade EC fans Compact design with max. 900 mm depth and 1900 mm height Low sound level with engineered unit design High flexibility with different heat exchanger types Standard LCD remote control with IQ control, optional Total Control available Easy service and maintenance with engineered unit design
Models NOTUS units are available for nominal air flow between 500 m3/h to 5000 m3/h in 6 different models. The units are designed for 2 different heat exchanger material; Aluminum and Plastic. The units have G4 class panel filters as standard and a selection of fine filters for replacing the standard filters for both air streams.
Unit Designation Series Name
Exchanger Type
Model
Extra Filter
Heating Capacity
POL
05 - 10 - 16 - 40
F6 - F7
S-M-L
AL
05 - 10 - 16 - 30 - 40 - 50
F6 - F7
S-M-L
NOTUS
EXAMPLE NOTUS - 16 - POL - F6 - M The designation indicates NOTUS unit with maximum airflow of 1600 m3/h and with polystyrene heat exchanger, F6 extra filter for fresh air and medium heating coil capacity.
3
Unit Specifications
Complete Package
Casing
NOTUS units have by-pass ventilation as standard. With bypass ventilation it is possible to use fresh air directly to cool indoors in the summer. The controller checks both indoor and outdoor air temperatures and user set temperature and switches on/ off the clamp integrated directly to the unit.
50 mm Mineral wool insulated panels are used in NOTUS units. The panels comprises of externally painted galvanized sheet metal and internally galvanized sheet metal. Appropriate gaskets are used to block heat and air leakage. The service doors are delivered with lockable latches.
Higher Energy Efficiency and Reduced Energy Consumption With the optimised heat exchanger, fans and other components the overall energy consumption of the unit is reduced by up to 20% compared to its ancestors. With the unique design of the heat exchanger and fans, NOTUS units ensure the highest level of energy efficiency for residential ventilation applications.
Greater Flexibility NOTUS units are equipped with the latest technology components and control system. Counterflow heat exchangers are used to increase the heat transfer in the heat recovery exchanger. NOTUS units are available with both aluminum and polystyrene heat exchangers. With polystyrene heat exchangers it is possible to extend heat recovery efficiency to up to 95% because of the unique structure of the air ducts inside the heat exchanger.
Enhanced Filtration Standard NOTUS units are equipped with G4 class filtration with 90% dust arrestance performance. F6 or F7 class filtration for fresh air is also available as an option. Control NOTUS units are equipped with IQ control. IQ control is capable of controlling EC fans, by-pass clamp, frost heater and operation timer. Fans can be controlled using three speed settings/unbalanced ventilation/ventilation on demand or constant flow. Two permanent temperature sensors measure return air/fresh air temperatures and control the by-pass. Filters are checked with a timer and the user is reminded when to carry out filter maintenance periodically. Optional total control is also available.
4
Compact Design
Low Sound Level
Notus units are designed for easy transport and installation. The maximum width of the unit does not exceed 900 mm and the maximum height is 1900 mm. With these specifications the unit can be transported and moved on the field easily.
With the innovative RadiCal blade design and the lower pressure drop of both components and internal design, the sound level of the unit is reduced along with the reduced fan speed. Thanks to the unique casing design, NOTUS units have high sound absorption character, reducing the radiated sound levels.
Dimensions
H
H
TYPE A
D
L1
L4 (/W Coil)
L2
L3
D
H
H
TYPE B
D
L1
L4 (/W Coil)
L2
L3
D
NOTUS with Aluminum Heat Exchanger
NOTUS
05 AL
Configuration
L1
L2
L3
L4
D
H
A
250
400
440
640
750
850
10 AL
A
250
500
550
750
850
1100
16 AL
A
250
650
550
750
900
1250
30 AL
B
250
1300
700
900
900
1250
40 AL
B
250
1500
700
900
900
1400
50 AL
B
250
1900
700
900
900
1600
05 POL
A
250
750
850
NOTUS with Polystrene Heat Exchanger 450
440
640
10 POL
B
250
800
550
750
900
1100
16 POL
B
250
1300
550
750
900
1250
40 POL
B
250
2300
700
900
900
1400
5
Performance Data NOTUS 05 • AIR PERFORMANCE
I
LwAin
qv
Pfs
3
W
A
dB (A)
m /h
Pa
1
146
1.17
76
1505
0
900
2
170
1.40
71
1225
200
850
3
170
1.40
67
975
350
4
160
1.28
73
560
500
700
5
104
0.84
73
1350
0
650
6
140
1.11
70
1145
176
7
142
1.12
66
915
309
8
125
1.00
71
515
423
9
60
0.49
69
1125
0
10
81
0.64
66
950
122
11
82
0.65
62
765
214
12
72
0.58
67
430
294
13
31
0.25
65
900
0
14
41
0.33
61
760
78
15
42
0.33
57
610
137
16
37
0.30
62
340
188
800 750
600 550 04
500 450
08
400
03
350 300
07
12
250 200
11
16
150
06
15
02
10
100
14
1800
1700
1600
1500
01
1400
05 1300
1100
900
800
700
600
500
400
300
200
0
100
09 1000
13
0
1200
50
Ped = Power Input • I = Current Draw LwAin = Sound power level inlet side • qv = Air flow Pfs = Pressure increase * Air performance and electrical data given for each fan seperately.
NOTUS 10 • AIR PERFORMANCE
Ped
I
LwAin
qv
Pfs
W
A
dB (A)
m /h
Pa
3
1
307
1.36
78
3250
0
2
404
1.77
73
2735
250
3
450
2.00
67
2105
450
4
399
1.75
72
1225
600
550
5
171
0.76
73
2675
0
500
6
225
0.99
68
2250
171
7
254
1.11
63
1735
308
8
222
0.97
67
1010
407
700 650 04
600
03
450 08
400 350
07
300
12 02
250 200
11
16
06
150
15
10
100
14
50
3500
3250
01 3000
2750
05 2500
09 2000
1750
1500
1250
1000
750
500
0
250
13
2250
0
6
Ped
9
99
0.44
69
2230
0
10
130
0.57
63
1875
119
11
147
0.64
58
1445
214
12
128
0.56
62
840
283
13
51
0.23
63
1780
0
14
67
0.29
58
1500
76
15
75
0.33
52
1155
137
16
66
0.29
57
670
181
Ped = Power Input • I = Current Draw LwAin = Sound power level inlet side • qv = Air flow Pfs = Pressure increase * Air performance and electrical data given for each fan seperately.
Performance Data NOTUS 16 • AIR PERFORMANCE
Ped
I
LwAin
qv
Pfs
3
W
A
dB (A)
m /h
Pa
1
307
1.36
78
3250
0
700
2
404
1.77
73
2735
250
650
3
450
2.00
67
2105
450
4
399
1.75
72
1225
600
5
171
0.76
73
2675
0
6
225
0.99
68
2250
171
7
254
1.11
63
1735
308
8
222
0.97
67
1010
407
04
600 550 500
03
450 08
400 350
07
300
12 02
250 200
11
16
06
150
15
10
100
14
50
3500
3250
01 3000
2750
05 2500
09 2000
1750
1500
1250
1000
750
500
0
250
13
2250
0
9
99
0.44
69
2230
0
10
130
0.57
63
1875
119
11
147
0.64
58
1445
214
12
128
0.56
62
840
283
13
51
0.23
63
1780
0
14
67
0.29
58
1500
76
15
75
0.33
52
1155
137
16
66
0.29
57
670
181
Ped = Power Input • I = Current Draw LwAin = Sound power level inlet side • qv = Air flow Pfs = Pressure increase * Air performance and electrical data given for each fan seperately.
NOTUS 30 • AIR PERFORMANCE
900 850 04
800 750 700 650
03
600 550 500 450
Ped
I
LwAin
qv
Pfs
W
A
dB (A)
m /h
Pa
3
1
656
1.14
87
5315
0
2
893
1.50
77
4345
400
3
1000
1.65
75
3390
650
4
918
1.54
78
2175
800
5
286
0.57
79
3945
0
6
350
0.68
70
3150
210
7
387
0.74
69
2450
350
8
366
0.70
70
1585
431
9
113
0.28
71
2620
0
10
133
0.31
64
2070
90
300
11
143
0.33
60
1595
146
250
12
135
0.32
61
1055
188
08
400
02
350
07
200
06
12
150
Ped = Power Input • I = Current Draw LwAin = Sound power level inlet side • qv = Air flow Pfs = Pressure increase
11
100
10
50 6000
5500
5000
01 4500
4000
3500
05 3000
2000
1500
1000
500
0
2500
09
0
7
Performance Data NOTUS 40 • AIR PERFORMANCE
I
LwAin
qv
Pfs
3
W
A
dB (A)
m /h
Pa
1
787
1.27
91
5565
0
1100
2
1039
1.65
83
4490
400
1000
3
1140
1.80
76
3450
700
4
1088
1.72
79
2270
900
5
444
0.71
86
4600
0
6
597
0.95
78
3735
278
7
651
1.03
72
2865
485
8
618
0.98
74
1880
619
900
04
800 03
700 08
600 500
07
400
02
12 11
300
06
16
200
10
15
100
14
7000
01 6000
05 4000
09 3000
2000
1000
0
13
5000
0
9
228
0.37
80
3680
0
10
306
0.49
73
2990
178
11
333
0.53
66
2295
311
12
316
0.50
68
1505
396
13
96
0.15
73
2760
0
14
129
0.21
65
2240
100
15
141
0.22
59
1720
175
16
133
0.21
61
1130
223
Ped = Power Input • I = Current Draw LwAin = Sound power level inlet side • qv = Air flow Pfs = Pressure increase
NOTUS 50 • AIR PERFORMANCE
Ped
I
LwAin
qv
Pfs
3
W
A
dB (A)
m /h
Pa
1
965
1.56
92
6930
0
1300
2
1239
1.99
88
5820
360
1200
3
1320
2.10
81
4060
700
1100
4
1267
2.03
84
2555
900
1000
5
592
0.96
88
5885
0
900
6
768
1.23
84
4975
259
7
877
1.41
78
3535
534
8
788
1.26
80
2180
659
04
800 700
03
08
600 07
500
12
400
11
02
16
300
06
15
200
10
09
05
01
6000
7000
8000
13
5000
3000
2000
1000
0
0
4000
14
100
8
Ped
9
342
0.55
83
4905
0
10
444
0.71
79
4150
180
11
507
0.81
73
2945
371
12
456
0.73
75
1820
457
13
175
0.28
77
3925
0
14
228
0.37
74
3320
115
15
260
0.42
68
2355
238
16
234
0.37
69
1455
293
Ped = Power Input • I = Current Draw LwAin = Sound power level inlet side • qv = Air flow Pfs = Pressure increase
Components Fans NOTUS units are equipped with centrifugal direct drive EC fans with backward blades following the latest development in HVAC technology. The impeller, electronics and the motor unites in NOTUS units ensuring a compact, perfectly matched, efficient, plug and play design. • Integrated locked-rotor and over-temperature protection • Suitable for 50 and 60 Hz mains • Continuously variable speed settings • Control signal 0-10 VDC and MODBUS • Integrated PID controller Long service life • Maintenance-free bearings • Brushless commutation High efficiency • Low copper and iron loss • No slip loss thanks to synchronous running • No magnetic reversal losses in the rotor due to permanent magnets being used High structural efficiency • Aerodynamically optimised blade duct • Integrated diffusor extension • Inlet nozzle adjusted to impeller
GreenTech EC fan
Unrivalled compactness - the GreenTech EC fan.. Conventional fans
...in contrast to conventional fans.
Low vibration • Dynamic balancing of the impeller rotor unit minimizes generation of structure-borne noise and reduces bearing load Low noise emissions & flow grid • Diagonal trailing edges for optimised flow control • Integrated diffusor extension • Inlet nozzle adjusted to impeller • Additional 9 dB sound reduction with optional inlet grid. Casing NOTUS units are developed with Mineral Wool insulated panels. Panels are delivered from 1,0 mm Galvanized Sheet Metal. Exterior panels are painted to light grey against corrosion. Gaskets made of Polyurethane foam with special surface coating are used for standard panels, for service panels specially formed Silicon based gaskets are used for thermal insulation and against leakage. Service doors are designed to service fans, filters, heat exchanger and control equipment easily. Service doors are with lock system for security and delivered with keys. NOTUS units are designed with separable sections for easy transport and access to the building.
9
Components Heat Exchanger Counterflow heat exchangers are used to increase the heat transfer in the heat recover exchanger. NOTUS units are available with both aluminum and polystyrene heat exchangers. With polystyrene heat exchangers it is possible to extend heat recovery efficiency to up to 96% because of the unique structure of the air ducts inside the heat exchanger. The triangular ducts in the polystyrene heat exchanger of NOTUS are arranged so that each one is surrounded by separate parallel ducts in which the air stream flow is in a "counterflow" flow pattern. This maximizes the heat transfer surface area and increases heat exchange efficiency. To decrease the pressure drop across the heat exchanger the dimensions are optimised in both aluminum and polystyrene heat exchangers.
NOTUS 05
NOTUS 10
NOTUS AL
NOTUS 16
Condensation
NOTUS 30
NOTUS 40
NOTUS 50
Dry
100% 90% 80% 70% 60% 50%
NOTUS POL
Condensation
Dry
100% 90% 80% 70% 60%
10
5000
4000
3000
1600
1000
500
0
50%
Components Casing NOTUS units are developed with Mineral Wool insulated panels. Panels are delivered from 1,0 mm Galvanized Sheet Metal. Exterior panels are painted to light grey against corrosion. Gaskets made of Polyurethane foam with special surface coating are used for standard panels, for service panels specially formed Silicon based gaskets are used for thermal insulation and against leakage. Service doors are designed to service fans, filters, heat exchanger and control equipment easily. Service doors are with lock system for security and delivered with keys.
Control NOTUS units are equipped with IQ control. IQ control is capable of controlling EC fans, by-pass clamp, frost heater and operation timer. Fans can be controlled using three speed settings/unbalanced ventilation/ventilation on demand or constant flow. Two permanent temperature sensors measure return air/fresh air temperatures and control the by-pass. Filters are checked with a timer and the user is reminded when to carry out filter maintenance periodically. By-Pass By-pass ventilation is used during summer and allows return air to by-pass the heat exchanger, thereby introducing fresh air at outdoor air temperature and cooling down indoors. NOTUS units are equipped with by-pass ventilation as standard. With the pre-installed temperature sensors IQ control checks return air temperature, fresh air temperature and user set temperature. According to the evaluation in the PCB, the bypass clamp is opened automatically. Warm Climate
Moderate Climate
5124 2523
6768
6437 1520
2024
1113
Cold Climate
299
Based on 24h operation
Heating Time / Year Cooling Time / Year By-Pass ventilation Time / Year
472
Filters Panel filters are used in NOTUS Units for standard filtration. The filtration class is G4 according to EN 779. G4 filters are medium efficiency disposable air filters suitable for ventilation applications with good dust-holding capacity. The filters consist of a dry non-woven extended surface fabric medium and create low initial pressure drop. For higher filtration demand NOTUS Units have extra filtration as an option. Extra filters are class F6 or F7 according to EN 779 and used to fine-filter fresh air. The filters consist of a non-flammable fabric medium which is pleated to extend the filtration surface and decrease the pressure drop. The pleated filter mediumis contained within the air filter by a rigid all cardboard casing. 11
Accessories Heating Despite the high thermal efficiency, to increase the supply air temperature in winter optional heating coils are available for NOTUS units. For heating fluid, steam or hot water is used. The coils are carefully engineered for an optimum balance between air side pressure drop and heat transfer coefficient. The coils are made of specially corrugated Aluminum fins and copper tubes. The fin spacing is limited to a minimum of 2,1 mm for easy cleaning and maintenance. Heating coil capacity is controlled by means of a modulating control valve and user set temperature. The modulating valve is integrated into NOTUS’s Total Control system.
Cooling Cooling coils (water or direct expansion) are available as optional equipment for NOTUS units. With cooling coils it is possible to cool down the supply air by means of chilled water or refrigerant removing both sensible and latent heat from fresh air. The coils are carefully engineered for an optimum balance between air side pressure drop and heat transfer coefficient. The coils are made of specially corrugated Aluminum fins and copper tubes. The fin spacing is limited to a minimum of 2,5 mm for easy cleaning and maintenance. To help the flow of the condensed water drops on the coil surface, the fins are coated with a special phenolic material. Cooling coil capacity is controlled by means of a modulating control valve and user set temperature. The modulating valve is integrated into NOTUS Total Control system. Droplet eliminators are used as standard with cooling coils in NOTUS units. A double slopped condensation tray made of stainless steel are used to drain condensed water. A siphon system made of ABS is delivered along with the units.
Fresh Air heater Electric or water driven coils are available for extreme climates for freeze protection. A freeze thermostat with a free contact is delivered with the coils to activate the circulation pump or start the electrical resistance elements. For water coils a glycol-water mix must be used.
12
Accessories Total Control NOTUS units are optionally available with the state of art “Total Control”. Total Control is a complete solution for the control of NOTUS units and delivered optionally with the units. It comprehends the latest technologies in communication and design, replacing the traditional hard-wired “on-site” solutions. All system configuration and site applications are performed by user friendly Web Interface that eases installation and commisioning work. The system includes all components required for controlling fans, electric and hydronic heating coils, cooling systems, drives for rotary heat exchangers and actuators in modern air handling units. The system components communicate via state-of-art bus technology while external communication is handled via standard bus systems required by the market. The master contains a high-performance processor unit and all interfaces into and out of the system.
Other Control Capabilities • Electric heating • Hydronic heating • Counter flow heat exchanger (new) • Cross-flow heat exchanger • Rotary heat exchanger • Hydronic heat exchanger • Water-based cooling • DX-based cooling • Filter surveilance • Actuator control of dampers • Error log • Alarm handling • Combi coil, heating and cooling in one coil • Control for external heat pumps • Automatic daylight saving
Web programming Through the built-in Web server, the system is configured via a standard browser on a PC. Via a multi-level user interface, the administrator can set up various levels for different groups. All the AHU operation is performed via the unique “Push &Turn” dial on the NOTUS hand terminal. Connectivity Total Control can be connected to a variety of systems: Modbus RTU, Modbus TCP/IP, internal Web server, BACNET and LON. Fan control • Constant flow • Constant pressure • Supply air pressure w. slave • Exhaust air pressure w. slave • Constant CO2 • Low speed / high speed (recirculation) • Constant operation • Automatic operation
13
Accessories Constant Flow Kit NOTUS units are equipped with EC fan controllers and differential pressure transmitters. The pressure transmitter monitors the pressure change in the fan inlet ring and calculates the air flow automatically. After the installation the user can set the air flow demand from the NOTUS Hand Terminal or the PC Interface and the Greentech EC fans will regulate the fan speed according to the set air flow. Eliminating the changes in pressure drop inside the unit (filters and other equipment) and in the duct system, NOTUS units will run with the design air flow as a result of the state of art Total Control.
Ventilation on Demand By use of additional CO2 /IAQ or RH sensor the demand indoors is calculated and the fan speed settings are adjusted accordingly. To switch to VOD mode, a proper sensor must be installed and connected, to the duct system and also the user must select “VOD” on Select Mode menu of the Remote Control. When VOD (Ventilation On Demand) is selected the fan speed is controlled by the analog 0-10V input signal.
Pressure Switch / Indicator NOTUS units are optionally available with visual pressure indicators and/or pressure switches. When the pre-set pressure difference is reached within the filters a generic alarm is generated from the Total Control and the user is warned for filter service.
14
www.impelair.com
15
impelair reserves the right to make alterations due to technical developments without prior notice.
111006008 - NOTUS SERIES FEB 2014
Impelair AS. Aegean Free Zone Gündüz Sokak D-1/D 35410 Gaziemir, Izmir Turkey Phone (+90) 232 251 70 20 Fax (+90) 232 251 57 38 www.impelair.com