Communication Products CFSP/CFRP.............................................................................................................................3 Fiber optic splice protector CFTV......................................................................................................................................5 Adhesive lined tubing for splice and connector protection CFTV QuickSeal™....................................................................................................................7 Adhesive wraparound sleeve for environmental sealing without disconnection CGEL......................................................................................................................................9 Gel filled closures for environmental protection of coaxial drop splices CTB-15.................................................................................................................................11 Self fusing tape DROP...................................................................................................................................13 Drop tubing
1
Communication Products Unique Solutions for Broad Band Communications DSG-Canusa is the leading manufacturer of outside plant protection products for broad band communications. Our innovative products prevent water ingress and mechanical damage to cables, splices and connectors.
USA: 800.422.6872
Canada: 800.845.6808
www.dsgcanusa.com
2
CFSP/CFRP Insulate Seal Protect
Fiber Optic Splice Protector A specially designed cross-linked polyolefin tubing system, with meltable liner, providing strength and protection to optical fiber splices
Features
and
Benefits
• Single fiber and ribbon fiber splice protector available • Single holed (preshrunk) ends eliminate improper fiber threading • Smooth, de-burred stainless steel reinforcing member ends decrease the risk of fiber damage during installation
• • • •
Extended liner length prevents contact between the fiber and the backbone Clear sleeve design permits easy centering of splice before heating Continuous operating temperature: -40°C to 60°C Shrink temperature: 90°C
Standards
• GR-1380 compliant
Typical Applications
• Protection of fusion splices in optical networks
3
CFSP/CFRP
Fiber Optic Splice Protector
Dimensions Order Number
Nominal Sleeve Length mm
Inside Diameter of Inner Liner (min.)
Nominal Support Rod Diameter*
Packaging
in
mm
in
mm
in
pieces/bag
Number of Splices
CFSP Single Fiber Protectors CFSP-12-61
61.0
2.40
1.5
0.06
1.2
0.05
100
1
CFSP-12-45
45.0
1.77
1.5
0.06
1.2
0.05
100
1
CFSP-12-23
23.0
0.90
1.5
0.06
1.2
0.05
100
1
1.57
3.0
0.12
1.8
0.07
50
CFRP Ribbon Fiber Protector CFRP-12
40.0
12
*Support rod for CFSP is made from stainless steel *Support rod for CFRP is made from ceramic
Ordering
• Refer to the table to select the CFSP/CRFP with the desired sleeve length for overlap on each end of the area to be covered.
• Order Example: CFSP-12-61 • Packaging: CFSP: 100 pieces per bag; CFRP: 50 pieces per bag Please contact your Customer Service Representative for information on custom colours, sizes, lengths and material data sheet. All information contained in this data sheet is believed to be reliable. We advise, however, that customers should separately evaluate the suitability of our products for their particular application. DSG-Canusa and ShawCor give no guarantees in respect of the accuracy or sufficiency of the information presented and disclaim any liability regarding its use. Our responsibilities are only those listed in our Standard Terms and Conditions of Sale for these products. In no instance will we be liable for any eventual, indirect or consequential damage or damages arising from the sale, resale, transfer, use or misuse of the product.
USA: 800.422.6872
Canada: 800.845.6808
www.dsgcanusa.com
4
CFTV
3:1 Shrink Ratio
Insulate Seal Protect
Heat Shrink Cable Sleeves Heat shrink tubing and adhesive liner combination that established the CATV industry standard for splice and connector protection
Features • • • • • • • • •
and
Benefits
Shrink ratio: 3:1 Craft friendly installation Exceptional split resistance CFTV adhesive retains bond providing long term protection Selective strippability to meet CATV industry specifications Minimal heat required to produce error free installation without splitting Thermochromatic lines change colour to signal waterproof seal Shrinks and seals in half the time of alternative products Continuous operating temperature: -55°C to 110°C
Typical Applications
• Strain relief of coaxial connectors • Waterproof protection of CATV connectors
5
CFTV
Heat Shrink Cable Sleeves Dimensions Expanded Order Number
Recovered
Internal Diameter (min.) D mm
in
0400
10.2
0.40
0750
19.0
1100
27.9
1300
Internal Diameter (max.) d mm
Wall Thickness (nom.) W
Application Range Use
for
General
Lengths
in
mm
in
mm
in
m
in
3.8
0.15
2
0.08
4.5 - 8.5
.18 - .34
1.2
48
0.75
5.6
0.22
2
0.08
6.0 - 16.5
.24 - .65
1.2
48
1.10
10.2
0.40
2
0.08
11.5 - 25.0
.45 - 1.0
1.2
48
33.0
1.30
10.2
0.40
2
0.08
11.5 - 30.0
.45 - 1.2
1.2
48
1500
38.1
1.50
12.7
0.50
2
0.08
14.0 - 35.0
.55 - 1.4
1.2
48
1700
43.2
1.70
12.7
0.50
2
0.08
14.0 - 40.0
.55 - 1.6
1.2
48
2050
52.1
2.05
19.0
0.75
2
0.08
21.0 - 45.0
.82 - 1.8
1.2
48
2750
69.8
2.75
25.4
1.00
2
0.08
30.0 - 63.0
1.2 - 2.5
1.2
48
Ordering
• Select a dimension which will shrink snugly over the component to be covered. If recovery is restricted the resulting wall thickness will be less than specified.
• Order Example: CFTV, 1700 Please contact your Customer Service Representative for information on custom sizes, lengths and material data sheet. All information contained in this data sheet is believed to be reliable. We advise, however, that customers should separately evaluate the suitability of our products for their particular application. DSG-Canusa and ShawCor give no guarantees in respect of the accuracy or sufficiency of the information presented and disclaim any liability regarding its use. Our responsibilities are only those listed in our Standard Terms and Conditions of Sale for these products. In no instance will we be liable for any eventual, indirect or consequential damage or damages arising from the sale, resale, transfer, use or misuse of the product.
USA: 800.422.6872
Canada: 800.845.6808
www.dsgcanusa.com
6
CFTV QuickSeal™
>3:1 Shrink Ratio
Insulate Seal Protect
Heat Shrink Wraparound Sleeve Heat shrink wraparound sleeve with adhesive for complete environmental sealing without the need for disconnection. Ideal for the protection of housing to housing connectors, retrofit protection of exposed connectors and the repair of damaged cable or fiber
Features • • • • • • • • •
and
Benefits
Shrink ratio: >3:1 Fast and simple installation without interruption of service Repair squirrel damaged cable Proven CANUSA CFTV adhesive ensures an absolutely waterproof seal Selective strippability to meet CATV industry specifications Minimal heat required to produce error free installation without splitting Thermochromatic lines that change colour upon correct shrink temperature CFTV QuickSeal™ can be cut to size in field to suit application Continuous operating temperature: -55°C to 110°C
Typical Applications
• Repair damaged cable and fiber • Retrofit protection of connectors without disconnecting
7
CFTV QuickSeal™
Heat Shrink Wraparound Sleeve
Dimensions Order Number
Length
Expanded Internal Diameter (max.) D
Width
Recovered Internal Diameter (max.) d
Recovered Wall Thickness (nom.) W
in
mm
in
mm
in
mm
in
mm
in
mm
1
36
914
7
178
1.7
43
0.55
14
0.06
1.5
2
9
229
7
178
1.7
43
0.55
14
0.06
1.5
Installation Notes
• CFTV QuickSeal™ is a one size fits all solution that can accommodate all sizes of cable and connectors.
CFTV QuickSeal™ can be cut to length and width in the field to fit the specific application. Simply wrap CFTV QuickSeal™ around the cable or connector, ensuring adequate overlap, and then firmly apply the closure to hold CFTV QuickSeal™ together during the heat shrinking process. Please refer to the installation instructions included with each CFTV QuickSeal™ for more detailed information.
Ordering
• Please specify the product name plus the options you require. • Order Example: CFTV QuickSeal™, 1, 36 in length Please contact your Customer Service Representative for information on custom sizes, lengths and material data sheet. All information contained in this data sheet is believed to be reliable. We advise, however, that customers should separately evaluate the suitability of our products for their particular application. DSG-Canusa and ShawCor give no guarantees in respect of the accuracy or sufficiency of the information presented and disclaim any liability regarding its use. Our responsibilities are only those listed in our Standard Terms and Conditions of Sale for these products. In no instance will we be liable for any eventual, indirect or consequential damage or damages arising from the sale, resale, transfer, use or misuse of the product.
USA: 800.422.6872
Canada: 800.845.6808
www.dsgcanusa.com
8
CGEL Insulate Seal Protect
Drop Splice Enclosure Gel filled closures are a simple, fast and effective method for providing complete environmental protection for coaxial drop splices
Features • • • •
and
Benefits
Single piece, clam shell design, requires no additional tools for installation Gel filled for complete waterproof protection Expansion chambers prevent Gel overflow Accommodates a wide range of environmentally sealed coaxial connectors and cable types including quad shielded cable
• Available in two sizes:
- CE 596 for 59 and 6 series cable
- CE 711 for 7 and 11 series cable
• • • •
Channel provided to retain messenger cable Fully re-enterable Tough outer shell withstands impacts to 5 ft-lb Withstands extreme temperatures (-45°C to 90°C
Standards
• Meets SCTE IPS-TP-013 (ANSI/SCTE 60
2004) requirements for water immersion and temperature cycling
Typical Applications
• Environmental protection of cable splices
9
CGEL
Drop Splice Enclosure
Dimensions Order Number
Nominal Diameter
Lengths
mm
in
mm
in
CE 596
25.4
1.0
116
4.6
CE 711
31.0
1.2
165
6.5
Applicable Cables Cables: All 59 and 6 series coaxial cables including quad shield with messengers
All 7 and 11 series coaxial cables including quad shield with messengers
Connectors 59
and
6 Series
7
and
11 Series
DIGCON
D2, Type II and S
D2, S and RG 11
T&B
F Series SNS Series
SNS Series
Corning GILBERT
GF Type AHS, UltraEase and Ultra Range
GAF AHS, UltraEase and Ultra Range
PPC
CMP, EX and AquaTight EX
EX and AquaTight EX
Others
F-Conn, Stirling
F-Conn, Stirling
Ordering
• Please specify the product name plus the options you require. • Order Example: CGEL, CE 596 • Packaging: 12 pieces per box All information contained in this data sheet is believed to be reliable. We advise, however, that customers should separately evaluate the suitability of our products for their particular application. DSG-Canusa and ShawCor give no guarantees in respect of the accuracy or sufficiency of the information presented and disclaim any liability regarding its use. Our responsibilities are only those listed in our Standard Terms and Conditions of Sale for these products. In no instance will we be liable for any eventual, indirect or consequential damage or damages arising from the sale, resale, transfer, use or misuse of the product.
USA: 800.422.6872
Canada: 800.845.6808
www.dsgcanusa.com
10
CTB-15 Insulate Seal Protect
Self Fusing Tape EPR based self fusing tape designed for the Communications industry
Features • • • • • • •
and
Benefits
Provides protection where heat/flame is prohibited Covers any shape including high transition areas and elbows Clean strippable Layers fuse together to form a boot that provides complete environmental protection and insulation UV and ozone resistant Proven long term protection Continuous operating temperature: -40°C to 90°C
Typical Applications
• Environmental protection of connectors in tight locations or when torch is not permitted
• Protect connectors in Cable TV, Wireless and Telecom applications
11
CTB-15
Self Fusing Tape
Dimensions Order Number
CTB-15
Width
Thickness
Roll Length
mm
in
mm
in
m
ft
38.1
1.5
0.76
0.03
4.57
15
Application Instructions • • • •
The surface of cable and connector should be clean. Start the tape on cable approximately two inches from connector. Make sure the tape is stretched during application. While stretching the tape, make one wrap on cable ensuring the tape is wrapped onto itself as it will only adhere to itself. Continue wrapping the cable and connector using half overlap layers.
• To terminate, wrap the tape onto itself and place your thumb at the termination point and stretch the tape until it breaks.
• Two layers are recommended • The loose end of the termination should be thumbed down.
Ordering
• Please specify the product name plus the options you require. • Order Example: CTB-15 All information contained in this data sheet is believed to be reliable. We advise, however, that customers should separately evaluate the suitability of our products for their particular application. DSG-Canusa and ShawCor give no guarantees in respect of the accuracy or sufficiency of the information presented and disclaim any liability regarding its use. Our responsibilities are only those listed in our Standard Terms and Conditions of Sale for these products. In no instance will we be liable for any eventual, indirect or consequential damage or damages arising from the sale, resale, transfer, use or misuse of the product.
USA: 800.422.6872
Canada: 800.845.6808
www.dsgcanusa.com
12
DROP
3:1 Shrink Ratio
Insulate Seal Protect
Drop Tubing Thin wall heat shrink tubing provides excellent environmental protection and insulation for CATV drop connectors
Features • • • • • • • •
and
Benefits
Shrink ratio: 3:1 Meltable inner liner encapsulates cable and connection completely Excellent UV and ozone resistance Resistant to all fluids and solvents Accommodates all F-Connectors and cables Flexible Continuous operating temperature: -55°C to 110°C Shrink temperature: 120°C
Typical Applications
• Sealing of coaxial drop connectors
13
DROP
Drop Tubing Dimensions Expanded Order Number
Recovered
Internal Diameter (min.) D
Internal Diameter (max.) d
Wall Thickness (nom.) W
Meltable Wall Thickness (nom.)
Lengths
mm
in
mm
in
mm
in
mm
in
m
in
0500
12.7
0.50
5.0
0.19
1.4
0.05
0.9
0.03
1.2
48
0750
19.1
0.75
8.0
0.31
1.7
0.06
1.0
0.04
1.2
48
Ordering
• Select a dimension which will shrink snugly over the component to be covered. If recovery is restricted the resulting wall thickness will be less than specified.
• Options: • Colour: Black (BK), Blue (BL) • Order Example: DROP Tubing, 0500, black, unprinted Please contact your Customer Service Representative for information on custom colours, sizes, lengths and material data sheet. All information contained in this data sheet is believed to be reliable. We advise, however, that customers should separately evaluate the suitability of our products for their particular application. DSG-Canusa and ShawCor give no guarantees in respect of the accuracy or sufficiency of the information presented and disclaim any liability regarding its use. Our responsibilities are only those listed in our Standard Terms and Conditions of Sale for these products. In no instance will we be liable for any eventual, indirect or consequential damage or damages arising from the sale, resale, transfer, use or misuse of the product.
USA: 800.422.6872
Canada: 800.845.6808
www.dsgcanusa.com
14
Americas DSG-Canusa, a division of ShawCor Inc. 173 Commerce Blvd. Cincinnati, Ohio 45140 USA Toll Free: Telephone: Fax: eMail:
800 422 6872 513 683 7800 513 683 7809
[email protected]
Canada / Asia Pacific DSG-Canusa, a division of ShawCor Ltd. 25 Bethridge Road Toronto, Ontario M9W 1M7 Canada Toll Free: Telephone: Fax: eMail:
800 845 6808 416 743 7111 416 743 7752
[email protected]
Europe / Middle East / Africa DSG-Canusa GmbH & Co. KG HeidestraBe 5 D-53340, Meckenheim Germany Telephone: Fax: eMail:
www.dsgcanusa.com
49 0 22 25/88 92-0 49 0 22 25/88 92-44
[email protected]
November 2007