Heaters With Auto Ignition, 1ph To Remote Cp4 Controller.

   EMBED


Share

Transcript

INDEX Diagram Number(s) SC3 CP4 CP2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 - 15 16 - Heater/Controller type Single Stage (On/Off) 1 phase supply Single Stage (On/Off) 3 phase supply Two Stage (Hi/Low) 1 phase supply Two Stage (Hi/Low) 3 phase supply Modulation 1 phase supply Modulation 3 phase supply Single Stage (On/Off) Heaters with Auto Ignition, 1Ph to remote SmartCom³ SZ. SmartCom Singlezone *IMPORTANT* 'Plug in' jumper MUST be in Neutral position NEUT LIVE (COMMON) (REMOTE OFF) B1 B0 B2 S/R0S/R1 (REMOTE ON) 10 (LOCKOUT INDICATION) 1/L 2/N (LIVE) 6 (NEUTRAL) REMOTE SWITCH INPUTS should be connected by 6A mains Max length is 100m. Low voltage switching inputs to be normally open (closed circuit to enable). Connect to B0 & B1 for remote ON (ie BMS time control). Connect to B0 & B2 for remote OFF (ie door interlock. remote frost etc). 5 *IMPORTANT* Add this link wire NOTES: 9 (HEAT 1 OUTPUT) 40 (VENT 1 OUTPUT) 41 (LOCKOUT RESET) 1 Room Sensor *The power supply is non-isolated, therefore all wiring to the control must be mains rated. (where applicable) REMOTE SENSOR(s) may be placed at a max distance of 100m from the control unit, using screened 6A mains* cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within Engineers functions for remote sensor. eg B.M.S. Controls cables min 0.75mm² cable for up to a distance of 200m. - - - - Optional features where requested (refer to heater wiring diagram.) *The power supply is non-isolated, therefore all wiring to the control must be mains rated. E N L Non-interrupted mains supply must be present at the heater 12 11 10 9 8 7 6 5 4 E3 N2 L1 Heater Installer connection terminal strip 2 Single Stage (On/Off) Heaters with Auto Ignition, 1Ph to remote CP4 controller. N MAINS E L + 1 2 S (LIVE) LOCKOUT L N (EARTH) RESET N.C. N.O. C (NEUTRAL) (HEAT 1 OUTPUT) HI/LOW (RELAY 3) (LOCKOUT INDICATION) HEAT (RELAY 2) (LOCKOUT RESET) FAN (RELAY 1) (VENT 1 OUTPUT) CP4 Controller Room Sensor (where applicable) Controls cables min 0.75mm² cable for up to a distance of 200m. NOTES: REMOTE SENSOR(s) may be placed at a max distance of 100m from the control unit, using Beldon 8451 (RS360-649 twin screened cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within engineers functions for remote sensor. 12 11 10 9 E N L Non-interrupted mains supply must be present at the heater 8 7 6 5 4 E3 N2 L1 Heater Installer connection terminal strip 3 Single Stage (On/Off) Heaters with Auto Ignition, 1Ph to remote CP2 controller. CP2 Controller 4 E3 N2 L1 (LIVE) 5 (NEUTRAL) 6 (HEAT 1 OUTPUT) 7 (EARTH) 8 (VENT 1 OUTPUT) (LOCKOUT INDICATION) (LOCKOUT RESET) 12 11 10 9 Controls cables min 0.75mm² cable for up to a distance of 200m. NOTES: REMOTE SENSOR(s) may be placed at a max distance of 100m from the control unit, using Beldon 8451 (RS360-649 twin screened cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within engineers functions for remote sensor. 12 11 10 9 E N L Non-interrupted mains supply must be present at the heater 8 7 6 5 4 E3 N2 L1 Heater Installer connection terminal strip 4 Single Stage (On/Off) Heaters with Auto Ignition, 3Ph to remote SmartCom³ SZ. SmartCom Singlezone *IMPORTANT* 'Plug in' jumper MUST be in Neutral position NEUT LIVE (COMMON) (REMOTE OFF) B1 B0 B2 S/R0S/R1 (REMOTE ON) (NEUTRAL) 10 (LOCKOUT INDICATION) 1/L 2/N (LIVE) 6 (HEAT 1 OUTPUT) REMOTE SWITCH INPUTS should be connected by 6A mains Max length is 100m. Low voltage switching inputs to be normally open (closed circuit to enable). Connect to B0 & B1 for remote ON (ie BMS time control). Connect to B0 & B2 for remote OFF (ie door interlock. remote frost etc). 5 (LOCKOUT RESET) NOTES: 9 *IMPORTANT* Add this link wire 40 (VENT 1 OUTPUT) 41 Room Sensor *The power supply is non-isolated, therefore all wiring to the control must be mains rated. (where applicable) REMOTE SENSOR(s) may be placed at a max distance of 100m from the control unit, using screened 6A mains* cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within Engineers functions for remote sensor. eg B.M.S. Controls cables min 0.75mm² cable for up to a distance of 200m. - - - - Optional features where requested (refer to heater wiring diagram.) *The power supply is non-isolated, therefore all wiring to the control must be mains rated. E N L3 L2 L1 Non-interrupted mains supply must be present at the heater 12 11 10 9 8 7 6 5 4 E Heater Installer connection terminal strip N L3 L2 L1 5 Single Stage (On/Off) Heaters with Auto Ignition, 3Ph to remote CP4 controller. N MAINS E L + 1 2 S (LIVE) LOCKOUT L N (EARTH) RESET N.C. N.O. C (NEUTRAL) (HEAT 1 OUTPUT) HI/LOW (RELAY 3) (LOCKOUT INDICATION) HEAT (RELAY 2) (LOCKOUT RESET) FAN (RELAY 1) (VENT 1 OUTPUT) CP4 Controller Room Sensor (where applicable) Controls cables min 0.75mm² cable for up to a distance of 200m. NOTES: REMOTE SENSOR(s) may be placed at a max distance of 100m from the control unit, using Beldon 8451 (RS360-649 twin screened cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within engineers functions for remote sensor. 12 11 10 9 E N L3 L2 L1 Non-interrupted mains supply must be present at the heater 8 7 6 5 4 E Heater Installer connection terminal strip N L3 L2 L1 6 Single Stage (On/Off) Heaters with Auto Ignition, 3Ph to remote CP2 controller. CP2 Controller 5 4 E3 N2 L1 (LIVE) (HEAT 1 OUTPUT) 6 (NEUTRAL) 7 (EARTH) 8 (VENT 1 OUTPUT) (LOCKOUT INDICATION) (LOCKOUT RESET) 12 11 10 9 Controls cables min 0.75mm² cable for up to a distance of 200m. NOTES: REMOTE SENSOR(s) may be placed at a max distance of 100m from the control unit, using Beldon 8451 (RS360-649 twin screened cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within engineers functions for remote sensor. 12 11 10 9 E N L3 L2 L1 Non-interrupted mains supply must be present at the heater 8 7 6 5 4 E Heater Installer connection terminal strip N L3 L2 L1 7 Two Stage (Hi/Low) Heaters with Auto Ignition, 1Ph to remote SmartCom³ MZ. SmartCom Mulitizone 41 40 7 8 9 25 14 5 *IMPORTANT* 'Plug in' jumper MUST be in Neutral position 6 LIVE 1/L 2/N 10 S/R0S/R1 D0 D1 O0 O1 B1 B0 B2 C2 C0 C1 66 64 20 (COMMON) (REMOTE OFF) (REMOTE ON) (LOCKOUT INDICATION) (LIVE) (NEUTRAL) *IMPORTANT* Add this link wire (HEAT 1 OUTPUT) (LOCKOUT RESET) (HEAT 2 OUTPUT) (HEAT 2 INPUT) (VENT 1 OUTPUT) NEUT C2 C0 C1 66 64 20 To other Slave Units OPTION NOTES: eg B.M.S. Duct Sensor (where applicable) Controls cables min 0.75mm² cable for up to a distance of 200m. - - - - Optional features where requested (refer to heater wiring diagram.) Room Sensor (where applicable) N E L Non-interrupted mains supply must be present at the heater 12 11 10 9 8 7 6 5 Heater Installer connection terminal strip 4 E3 N2 L1 NETWORK OPTION: Master-slave (Network) communication is by screened twisted pair cable, RS485 compatible such as Belden 9841. Maximum overall system length of 500m. Connect screen to C0. NOTE: Diagram shows a master and ONE slave configuration**. Wire further slaves in parallel. REMOTE SWITCH INPUTS should be connected by 0.75mm² cable. Max length is 100m. Low voltage switching inputs to be normally open (closed circuit to enable). Connect to B0 & B1 for remote ON (ie BMS time control). Connect to B0 & B2 for remote OFF (ie door interlock. remote frost etc). For Master/Slave networks, remote OFF can be set for individual zones or total system via the Master. REMOTE SENSOR(s) may be placed at a max distance of 100m from the control unit, using screened 0.75mm² cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within Engineers functions for remote sensor. 8 Two Stage (Hi/Low) Heaters with Auto Ignition, 1Ph to remote CP4 controller. (LOCKOUT RESET) N MAINS E L + 1 2 S (LIVE) (HEAT 2 OUTPUT) LOCKOUT L N (EARTH) (HEAT 1 OUTPUT) RESET N.C. N.O. C (NEUTRAL) HI/LOW (RELAY 3) (LOCKOUT INDICATION) HEAT (RELAY 2) (HEAT 2 INPUT) FAN (RELAY 1) (VENT 1 OUTPUT) CP4 Controller Room Sensor (where applicable) Controls cables min 0.75mm² cable for up to a distance of 200m. NOTES: REMOTE SENSOR(s) may be placed at a max distance of 100m from the control unit, using Beldon 8451 (RS360-649 twin screened cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within engineers functions for remote sensor. 12 11 10 9 E N L Non-interrupted mains supply must be present at the heater 8 7 6 5 4 E3 N2 L1 Heater Installer connection terminal strip 9 Two Stage (Hi/Low) Heaters with Auto Ignition, 1Ph to remote CP2 controller. CP2 Controller (LIVE) 4 E3 N2 L1 (NEUTRAL) 5 (EARTH) 6 (HEAT 1 OUTPUT) 7 (HEAT 2 INPUT) (VENT 1 OUTPUT) 8 (HEAT 2 OUTPUT) (LOCKOUT INDICATION) (LOCKOUT RESET) 12 11 10 9 Controls cables min 0.75mm² cable for up to a distance of 200m. NOTES: REMOTE SENSOR(s) may be placed at a max distance of 100m from the control unit, using Beldon 8451 (RS360-649 twin screened cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within engineers functions for remote sensor. 12 11 10 9 E N L Non-interrupted mains supply must be present at the heater 8 7 6 5 4 E3 N2 L1 Heater Installer connection terminal strip 10 Two Stage (Hi/Low) Heaters with Auto Ignition, 3Ph to remote SmartCom³ MZ. SmartCom Mulitizone 41 40 7 8 9 25 14 5 *IMPORTANT* 'Plug in' jumper MUST be in Neutral position 6 1/L 2/N LIVE 10 S/R0S/R1 D0 D1 O0 O1 B1 B0 B2 C2 C0 C1 66 64 20 (COMMON) (REMOTE OFF) (REMOTE ON) (LOCKOUT INDICATION) (LIVE) (NEUTRAL) *IMPORTANT* Add this link wire (HEAT 1 OUTPUT) (LOCKOUT RESET) (HEAT 2 OUTPUT) (HEAT 2 INPUT) (VENT 1 OUTPUT) NEUT C2 C0 C1 66 64 20 To other Slave Units OPTION NOTES: eg B.M.S. Duct Sensor (where applicable) Controls cables min 0.75mm² cable for up to a distance of 200m. - - - - Optional features where requested (refer to heater wiring diagram.) Room Sensor (where applicable) E N L3 L2 L1 Non-interrupted mains supply must be present at the heater 12 11 10 9 8 7 6 5 Heater Installer connection terminal strip 4 E N L3 L2 L1 NETWORK OPTION: Master-slave (Network) communication is by screened twisted pair cable, RS485 compatible such as Belden 9841. Maximum overall system length of 500m. Connect screen to C0. NOTE: Diagram shows a master and ONE slave configuration**. Wire further slaves in parallel. REMOTE SWITCH INPUTS should be connected by 0.75mm² cable. Max length is 100m. Low voltage switching inputs to be normally open (closed circuit to enable). Connect to B0 & B1 for remote ON (ie BMS time control). Connect to B0 & B2 for remote OFF (ie door interlock. remote frost etc). For Master/Slave networks, remote OFF can be set for individual zones or total system via the Master. REMOTE SENSOR(s) may be placed at a max distance of 100m from the control unit, using screened 0.75mm² cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within Engineers functions for remote sensor. 11 Two Stage (Hi/Low) Heaters with Auto Ignition, 3Ph to remote CP4 controller. (LOCKOUT RESET) N MAINS E L + 1 2 S (LIVE) (HEAT 2 OUTPUT) LOCKOUT L N (EARTH) (HEAT 1 OUTPUT) RESET N.C. N.O. C (NEUTRAL) HI/LOW (RELAY 3) (LOCKOUT INDICATION) HEAT (RELAY 2) (HEAT 2 INPUT) FAN (RELAY 1) (VENT 1 OUTPUT) CP4 Controller Room Sensor (where applicable) Controls cables min 0.75mm² cable for up to a distance of 200m. NOTES: REMOTE SENSOR(s) may be placed at a max distance of 100m from the control unit, using Beldon 8451 (RS360-649 twin screened cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within engineers functions for remote sensor. 12 11 10 9 E N L3 L2 L1 Non-interrupted mains supply must be present at the heater 8 7 6 5 4 E Heater Installer connection terminal strip N L3 L2 L1 12 Two Stage (Hi/Low) Heaters with Auto Ignition, 3Ph to remote CP2 controller. CP2 Controller 4 E3 N2 L1 (LIVE) 5 (NEUTRAL) (HEAT 1 OUTPUT) 6 (EARTH) 7 (HEAT 2 INPUT) (VENT 1 OUTPUT) 8 (HEAT 2 OUTPUT) (LOCKOUT INDICATION) (LOCKOUT RESET) 12 11 10 9 Controls cables min 0.75mm² cable for up to a distance of 200m. NOTES: REMOTE SENSOR(s) may be placed at a max distance of 100m from the control unit, using Beldon 8451 (RS360-649 twin screened cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within engineers functions for remote sensor. 12 11 10 9 E N L3 L2 L1 Non-interrupted mains supply must be present at the heater 8 7 6 5 4 E Heater Installer connection terminal strip N L3 L2 L1 13 Modulation Heaters with Auto Ignition, 1Ph to remote SmartCom³ MZ. SmartCom Mulitizone 40 7 8 9 25 14 5 6 1/L 2/N LIVE 10 S/R0S/R1 D0 D1 O0 O1 B1 B0 B2 C2 C0 C1 66 64 20 12 11 10 9 (COMMON) (0 - 10Vdc output) (COMMON) (REMOTE OFF) (REMOTE ON) (NEUTRAL) (LOCKOUT INDICATION) (LIVE) *IMPORTANT* Add this link wire C2 C0 C1 66 64 20 Controls cables min 0.75mm² cable for up to a distance of 200m. - - - - Optional features where requested (refer to heater wiring diagram.) 0-10V outputs should be connected by 0.75mm² cable. Max length is 100m. (HEAT 1 OUTPUT) (LOCKOUT RESET) NEUT (VENT 1 OUTPUT) 41 *IMPORTANT* 'Plug in' jumper MUST be in Neutral position To other Slave Units OPTION NOTES: eg B.M.S. Duct Sensor (where applicable) Room Sensor (where applicable) N E L Non-interrupted mains supply must be present at the heater 8 7 6 5 4 E3 N2 L1 Heater Installer connection terminal strip NETWORK OPTION Master-slave (Network) communication is by screened twisted pair cable, RS485 compatible such as Belden 9841. Maximum overall system length of 500m. Connect screen to C0. NOTE: Diagram shows a master and ONE slave configuration**. Wire further slaves in parallel. REMOTE SWITCH INPUTS should be connected by 0.75mm² cable. Max length is 100m. Low voltage switching inputs to be normally open (closed circuit to enable). Connect to B0 & B1 for remote ON (ie BMS time control). Connect to B0 & B2 for remote OFF (ie door interlock. remote frost etc). For Master/Slave networks, remote OFF can be set for individual zones or total system via the Master. REMOTE SENSOR(s) may be placed at a max distance of 100m from the control unit, using screened 0.75mm² cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within Engineers functions for remote sensor. 14 Modulation Heaters with Auto Ignition, 1Ph to to remote CP4 controller. N MAINS E L + 1 2 S (LIVE) LOCKOUT L N (EARTH) RESET N.C. N.O. C (NEUTRAL) HI/LOW (RELAY 3) (LOCKOUT INDICATION) HEAT (RELAY 2) (LOCKOUT RESET) FAN (RELAY 1) (HEAT 1 OUTPUT) (0-10V OUTPUT) S S + (VENT 1 OUTPUT) CP4 Controller Room Sensor (where applicable) Controls cables min 0.75mm² cable for up to a distance of 200m. NOTES: REMOTE SENSOR(s) may be placed at a max distance of 100m from the control unit, using Beldon 8451 (RS360-649 twin screened cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within engineers functions for remote sensor. E N L Non-interrupted mains supply must be present at the heater 12 11 10 9 8 7 6 5 4 E3 N2 L1 Heater Installer connection terminal strip 15 Modulation Heaters with Auto Ignition, 3Ph to remote SmartCom³ MZ. SmartCom Mulitizone 40 7 8 9 25 14 5 6 1/L 2/N LIVE 10 S/R0S/R1 D0 D1 O0 O1 B1 B0 B2 C2 C0 C1 66 64 20 12 11 10 9 (COMMON) (0 - 10Vdc output) (COMMON) (REMOTE OFF) (REMOTE ON) (NEUTRAL) (LOCKOUT INDICATION) (LIVE) *IMPORTANT* Add this link wire C2 C0 C1 66 64 20 Controls cables min 0.75mm² cable for up to a distance of 200m. - - - - Optional features where requested (refer to heater wiring diagram.) 0-10V outputs should be connected by 0.75mm² cable. Max length is 100m. (HEAT 1 OUTPUT) (LOCKOUT RESET) NEUT (VENT 1 OUTPUT) 41 *IMPORTANT* 'Plug in' jumper MUST be in Neutral position To other Slave Units OPTION NOTES: eg B.M.S. Duct Sensor (where applicable) Room Sensor (where applicable) E N L3 L2 L1 Non-interrupted mains supply must be present at the heater 8 7 6 5 4 E Heater Installer connection terminal strip N L3 L2 L1 NETWORK OPTION Master-slave (Network) communication is by screened twisted pair cable, RS485 compatible such as Belden 9841. Maximum overall system length of 500m. Connect screen to C0. NOTE: Diagram shows a master and ONE slave configuration**. Wire further slaves in parallel. REMOTE SWITCH INPUTS should be connected by 0.75mm² cable. Max length is 100m. Low voltage switching inputs to be normally open (closed circuit to enable). Connect to B0 & B1 for remote ON (ie BMS time control). Connect to B0 & B2 for remote OFF (ie door interlock. remote frost etc). For Master/Slave networks, remote OFF can be set for individual zones or total system via the Master. REMOTE SENSOR(s) may be placed at a max distance of 100m from the control unit, using screened 0.75mm² cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within Engineers functions for remote sensor. 16 Modulation Heaters with Auto Ignition, 3Ph to to remote CP4 controller. LOCKOUT L N (LOCKOUT INDICATION) N MAINS E L + 1 2 S (LIVE) RESET N.C. N.O. C (EARTH) HI/LOW (RELAY 3) (NEUTRAL) HEAT (RELAY 2) (LOCKOUT RESET) FAN (RELAY 1) (HEAT 1 OUTPUT) (0-10V OUTPUT) S S + (VENT 1 OUTPUT) CP4 Controller Room Sensor (where applicable) Controls cables min 0.75mm² cable for up to a distance of 200m. NOTES: REMOTE SENSOR(s) may be placed at a max distance of 100m from the control unit, using Beldon 8451 (RS360-649 twin screened cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within engineers functions for remote sensor. E N L3 L2 L1 Non-interrupted mains supply must be present at the heater 12 11 10 9 8 7 6 5 4 E Heater Installer connection terminal strip N L3 L2 L1 NOTES: Document reference number GB/CON/012/1010 Benson Ludlow Road Knighton Powys LD7 1LP United Kingdom. Telephone 01547 528534 Facsimile 01547 520399 Email [email protected] Website www.bensonheating.co.uk Benson Heating is a registered trademark of Benson Heating Limited. Because of continuous product innovation, Benson Heating reserve the right to change product specification without due notice