Preview only show first 10 pages with watermark. For full document please download

Hgt-2101 Physical Specifications

   EMBED


Share

Transcript

A F E D C B G H K J REVISIONS 1 0.012 TYP REV. BY DATE DESCRIPTION ECO# A STE 3/23/2010 INITIAL RELEASE - 1 0.018±0.003 0.006 + Ic Vh ACTIVE AREA LOCATION 2 2 0.065 LOT MARKING ON TOP OF CASE WITH RESPECT TO PIN POLARITY + Vh 0.098 Ic 3 3 B+ 4 4 0.030 SPECIFICATIONS 0.035 5 .020" SQUARE PADS (4X) INPUT RESISTANCE 450 TO 900 OHMS INPUT RESISTANCE 600 TO 2000 OHMS NOMINAL CONTROL CURRENT 1mA MAX. CONTINUOUS CURRENT 10mA (IN 25 C STATIC AIR) MAGNETIC SENSITIVITY (Ic=1mA) 11 TO 28 mV/kG LINEARITY ERROR (SENS. vs FIELD) 2% TO 10kG (MAX.) ZERO FIELD OFFSET (Ic=1mA) MOUNTING PAD SIZE AND LOCATION 6 0.090 UNLESS OTHERWISE SPECIFIED: ALL DIMENSIONS ARE INCHES AND APPLY AFTER ANY FINISHES. 0.035 A B C 1 PLACE: .03 2 PLACES: .01 3 PLACES: .005 D E F 4 PLACES: .0005 FRACTIONS: 1/16 ANGLES: 1 G 2.8 mV (MAX.) OPERATING TEMPERATURE -40 TO +125 C TEMP. COEFFICIENT (SENSITIVITY) -0.06 %/ C TEMP. COEFFICIENT (RESISTANCE) 0.3 %/ C DATE: DATE: 3/23/2010 TYPE: ASSY FILE: 261-003 PART NUMBER: 261-003 SIZE: B SCALE: 24:1 H 6 DATE: 3/23/2010 DRAWN BY: LAKE SHORE CRYOTRONICS (LSCI) PROPRIETARY. NOT TO STE BE COPIED, USED, OR DISCLOSED WITHOUT PRIOR WRITTEN CHECKED BY: PERMISSION BY LSCI AND SHALL BE RETURNED UPON REQUEST. MODELED IN SOLIDWORKS. SOLIDWORKS FILE (.SLDPRT) AVAILABLE FOR USE AS A CONSTRUCTION APPROVED BY: AID UPON REQUEST. TBM 7 5 7 DESCRIPTION: HGT-2101 SURFACE MOUNT HALL GENERATOR PAGE: 1 OF 1 DRAWING NUMBER: 023-10-00 J K REV: A