Preview only show first 10 pages with watermark. For full document please download

Hh0-005 Hitachi Tagmastore Ams And Wms-installation And Configration

   EMBED


Share

Transcript

http://www.TwPass.com HH0-005 Hitachi TagmaStore AMS and WMS-Installation and Configration http://www.twpass.com/twpass.com/exam.aspx?eCode= HH0-005 The HH0-005 practice exam is written and formatted by Certified Senior IT Professionals working in today's prospering companies and data centers all over the world! The HH0-005 Practice Test covers all the exam topics and objectives and will prepare you for success quickly and efficiently. The HH0-005 exam is very challenging, but with our HH0-005 questions and answers practice exam, you can feel confident in obtaining your success on the HH0-005 exam on your FIRST TRY! Hitachi HH0-005 Exam Features - Detailed questions and answers for HH0-005 exam - Try a demo before buying any Hitachi exam - HH0-005 questions and answers, updated regularly - Verified HH0-005 answers by Experts and bear almost 100% accuracy - HH0-005 tested and verified before publishing - HH0-005 exam questions with exhibits - HH0-005 same questions as real exam with multiple choice options Acquiring Hitachi certifications are becoming a huge task in the field of I.T. More over these exams like HH0-005 exam are now continuously updating and accepting this challenge is itself a task. This HH0-005 test is an important part of Hitachi certifications. We have the resources to prepare you for this. The HH0-005 exam is essential and core part of Hitachi certifications and once you clear the exam you will be able to solve the real life problems yourself.Want to take advantage of the Real HH0-005 Test and save time and money while developing your skills to pass your Hitachi HH0-005 Exam? Let us help you climb that ladder of success and pass your HH0-005 now! HH0-005 QUESTION: 1 A customer has an AMS500 consisting of: Unit 00: RKM with six 300GB FC HDDs in position 00 to 05 Unit 01: RKAJAT with five 250GB SATA HDDs in position 00 to 04 and four 400GB SATA HDDs in position 05 to 08 Unit 02: same as Unit 01 You now want to create a R5(7+1) SATA RAID Group What happens if you choose the Automatic selection button in the RAID Group creation dialog and your parity group value is 1? A: You cannot define a SATA RAID Group before the definition of a spare disk B:The RAID Group will be created using Unit 01 HDDs 00 to 04 and Unit 02 HDDs 00 to 02 C: The dialog will end with an error because (7+1) is not an appropriate size for a SATA RAID Group D: The Automatic creation dialog will choose SATA HDDs in sequential order, which is Unit 01 HDDs 00 to 07 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=1 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 2 An AMS200 has the optional FC host interface feature installed Which two statements correctly describe the FC port configuration supported by this storage subsystem? (Choose two) A: Maximum one FC interface port per controller B:Maximum two FC interface ports per controller C: Maximum three FC interface ports per controller D: Maximum four FC interface ports per system Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=2 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 3 Which combination of features and parameters can be configured with the AMS/WMS Cache Partition Manager? A: Partitioning of the Cache, Cache partition segment size, HDD stripe size, Read-data mirroring on/off B:Partitioning of the Cache, Cache partition stripe size, HDD segment size, Write-data mirroring on/off C: Partitioning of the Cache, Cache partition segment size, HDD stripe size, Write-data mirroring on/off D: Partitioning of the Cache, Cache partition segment size, HDD stripe size, Cache destage algorithm Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=3 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 4 Which statement regarding Cache Partition Manager is correct? A: It allows upgrading the controller Cache online B:It allows switching on/off Read after Write for SATA drives C: It is used to set boundaries between Read and Write Cache D: It allows separating slow LUNs from fast LUNs in the Cache Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=4 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 5 A customer using an AMS500 with mixed FC and SATA drives wants to take advantage of the HDD Roaming feature You have started to define a RAID Group R5(4+1) with a FC disk in unit 0 position 0 Which three valid options can you now consider? (Choose three) A: Spread the R5(4+1) group over several RKAJs B:Extend the defined R5(4+1) group into a (5+1) group on the fly C: Assign four FC disks and one SATA disk to the R5(4+1) group D: Choose any other position in the subsystem for defining a FC spare disk EAdd any other FC disk of any size and speed to the RAID Group starting at 0,0 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=5 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 6 Which three restrictions related to the controller front-end architecture apply to the WMS100 and AMS200 series? (Choose three) A: The transfer rate for both mini-hub connectors must be set to the same speed B:Both connectors on the same mini-hub must be connected to the same Fabric C: The microcode disables the second mini-hub connector in case of Fabric connection D: Both connectors on the same mini-hub must be connected through a Fabric to different hosts EThe LUN management functions must be used to share the original port by 2 hosts through the same mini-hub Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=6 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 7 4 Which statement correctly describes the difference between AMS200 and AMS500 back-end loop architectures? A: The AMS200 has two independent back-end loops B:The AMS200 has only one logical loop per controller that is shared by all HDDs C: In the AMS200 the same ALPA can occur on the two different physical loops on the same controller D: The AMS200 uses two different World-Wide-Names (WWNs) for connectors #0 and #1 on each controller Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=7 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 8 An AMS500 connected to a host running Hitachi Dynamic Link Manager (HDLM) software has the Data Share Mode set to on The host is using multi-path to access the same single LUN through the four front-end FC ports of the AMS500 Which two statements are true? (Choose two) A: Host I/Os switch to non-owner path if all owner paths are down B:Host I/Os go through all the four FC ports of the AMS500 at same time C: By default, Host I/Os only go through the owner path via owner controller FC ports D: Host I/Os do not need switching paths with Data Share Mode on when all owner paths are down Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=8 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 9 Which two statements relating to the concept of LUN ownership and its implication on configuration best practices in HDLM and non-HDLM environments are correct? (Choose two) A: HDLM can only fail-over to the other controller B:HDLM can automatically fail-back to the original path C: When one LUN switches ownership, all other LUNs on the same controller follow D: When a LUN is no longer accessed via the owning controller, but via the nonowning controller, it will change ownership after sixty seconds Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=9 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 10 Which two statements relating to AMS/WMS microcode upgrade are correct? (Choose two) A: The AMS/WMS microcode is by default located on the System Area of the first five hard disk drives 5 B:The AMS/WMS hard disk drive Roaming feature allows for the microcode to be stored onto the User Area of any hard disk C: It is possible to perform an online microcode upgrade using the Web Tool when the Host application runs HDLM multi-path support D: It is possible to perform an online microcode upgrade using Storage Navigator Modular when the Host application runs HDLM multi-path support via both controllers Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=10 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 11 What are three criteria to consider when creating a RAID Group on an AMS/WMS storage system? (Choose three) A: The total number of global spare disks B:The RAID level and the RAID geometry of the RAID Group C: The physical drive types (FC or SATA) to be used in the RAID Group D: The placement of the same RAID Group across RKAJs and RKAJATs EThe I/O characteristics (high sequential, high random, large blocks) of the application that will be running on the LUNs within the RAID Group Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=11 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 12 Which two are valid examples of disk configuration information displayed in Storage Navigator Modular (SNM) ? (Choose two) A: LU capacity B:Microprogram C: RAID configuration D: SNMP agent information Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=12 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 13 Which two operations can be performed with the WEB Utility? (Choose two) A: Change the RK Serial Number B:Perform an ENC Firmware update C: Perform an offline microcode update D: Perform an online microcode update 6 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=13 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 14 Which two sets of operations can be performed with the WEB Tool in Normal Mode? (Choose two) A: Monitor a system, take a dump B:Change the buzzer volume, take a trace C: Manage TrueCopy, ShadowImage and Snapshot pairs D: Monitor the system for hardware status, error and progress messages Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=14 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 15 Which two statements relating to Storage Navigator Modular (SNM) are correct? (Choose two) A: Storage Navigator Modular allows you to change the Boot options within the System Parameters on the fly B:Storage Navigator Modular allows you to change the LAN port number which is used to connect to the subsystem C: Storage Navigator Modular can be used to define the Command Devices and the Differential Management LUNs needed by data replication software D: Storage Navigator Modular uses out of band communication in order to administer the subsystem and in-band communication in order to run data replication software Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=15 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 16 What is the prerequisite condition for using the Storage Navigator Modular (SNM) GUI? A: Storage Navigator Modular must be installed on a Windows platform B:Storage Navigator Modular can only be used from the time the array unit becomes ready C: Storage Navigator Modular can only be used to install and configure AMS/WMS storage systems D: Java Runtime environment must be installed manually prior to installing Storage Navigator Modular on a Windows platform Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=16 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 17 A system administrator who worked on a specific AMS storage system went home, leaving his workstation with an open Storage Navigator Modular (SNM) unit window The Password Protection feature is not configured, and an operator arrives who now needs to work with this particular storage array from another PC: What should the operator do to access the AMS storage system? A: Do a forced login with SNM-GUI B:Do a forced login with SNM-CLI C: Nothing, access is possible and allowed D: Reboot the subsystem to allow access again Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=17 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 18 An AMS500 has one R5(3+1) FC RAID Group and one R6(8+2) SATA RAID Group You want to create fifteen LUNs with a size of 10GB each and twenty-five LUNs with a size of 25GB each Twenty of them should reside on the FC HDDs, the other twenty should reside on SATA HDDs Moreover you want to map the FC LUNs to ports 0A and 1A and the SATA LUNs to ports 0B and 1B: How often do you need to invoke the Logical Unit (LU) Wizard? A: One time only B:Twice: one time for the 10GB LUNs and one time for the 25GB LUNs C: Three times: one time for the fifteen 10GB FC drives, one time for the five 25GB FC drives and one time for the twenty 25GB SATA drives D: The Logical Unit Wizard cannot be used because it does not support creation of LUNs on SATA HDDs Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=18 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 19 What are the three required steps to provide a host with a single LUN using LUN management? (Choose three) A: Format the LUN B:Create a Host Group C: Run parity correction D: Enable owner path by mapping ESelect the Operating System type for the Host Group Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=19 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 20 Which statement relating to LUN deletion on AMS/WMS storage systems is correct? A: When a LUN is invalidated, its data is kept by the system B:Only a RAID Group with RAID Level 0 can be deleted because there is no protection C: It is possible to restore a deleted LUN definition with the Constitute dialog in Storage Navigator Modular D: Corrupted data within LUNs can always be rebuilt using the parity correction dialog in Storage Navigator Modular Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=20 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 21 Which two statements relating to the AMS/WMS ACE tool are correct? (Choose two) A: The ACE tool provides a Device ID setting for each AMS/WMS module B:The ACE SNM embedded tool generates array topology including hosts and switches C: A separate tool is needed to help designing Device ID and back-end loop for optimal performance D: The ACE SNM embedded tool generates a cable connection diagram for the AMS/WMS back-end Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=21 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 22 Which two parameters can be selected in the Simple option of a Host Group? (Choose two) A: The front-end Fibre Channel port speed B:The front-end Fibre Channel port topology C: The Operating System platform running on the host D: The type of High-Availability software running on the host for alternate pathing Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=22 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 23 In which three cases a path to an AMS/WMS storage system controlled by the Hitachi Dynamic Link Manager (HDLM) software can get into the Offline status and be prevented from receiving I/Os? (Choose three) 9 A: An error occurred in the owner path B:HDLM detected a failure on the last path accessing a device C: Dynamic sparing started, impacting LUNs on the owner path D: A user executed a microcode replacement to the owner path EA user placed the path offline using the path management window from the HDLM GUI Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=23 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 24 There is a problem on an AMS500 owner path What is the impact of the owner path failure on the Hitachi Dynamic Link Manager (HDLM) software load balancing mechanism? (Choose two) A: Load Balancing is performed using the remaining usable owner paths B:Load balancing is disabled when connected to an AMS500 storage system C: When all owner paths are unavailable, load balancing is performed using non-owner paths D: To prevent performance degradation HDLM performs load balancing between the remaining owner path and a nonowner path Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=24 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 25 Which command can be used to easily and quickly display the status of each Hitachi Dynamic Link Manager (HDLM) software parameter? A: Dlnkmgr set -sys B:Dlnkmgr view -sys C: Dlnkmgr status -sys D: Dlnkmgr display -sys Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=25 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 26 An operator left a workstation logged into an AMS/WMS storage system with a Storage Navigator Modular (SNM) session open and the Password Protection feature enabled and configured A system administrator now needs to log into the system Which two options does the system administrator have in order to access the device? (Choose two) A: Do a forced login with SNM-CLI B:Do a forced login with SNM-GUI 10 C: Wait for the operator to return and ask him to log out D: Log into the subsystem normally since two users can be logged in simultaneously Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=26 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 27 Which two operations can be performed on an AMS/WMS storage system with the LUN Expansion feature (LUSE)? (Choose two) A: Expand up to 128 LUNs together B:Delete any LUN in a LUSE group C: Expand unformatted LUNs together D: Expand LUNs together without rebooting Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=27 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 28 Which two operations can be performed with the LUN Manager? (Choose two) A: Create Host Groups B:Map LUNs to a Host Group C: Define Raid Groups and LUNs D: Provide the AMS WWN for LUN Security Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=28 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 29 Which three statements relating to the Performance Monitor feature are correct? (Choose three) A: Performance Monitor is needed to evaluate and analyze performance data B:Performance Monitor shows how much space has been used in a particular LUN C: Performance Monitor will start monitoring only after the Performance Statistics Collection has been set D: It is possible to manage an AMS500 and run Performance Monitor in parallel from the same Storage Navigator Modular EPerformance Monitor displays the acquired performance information graphically and can output this data to a csv file Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=29 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 30 Which three Program Products require a Licence Key for Storage Navigator Modular (SNM)? (Choose three) A: HDLM B:LUN Manager C: TrueCopy Software D: Performance monitor ERaid Manager program (CCI) Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=30 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 31 What is the correct sequence of actions to be followed when setting up TrueCopy on both a local and a remote site? A: Install Raid Manager CCI, enable the TrueCopy option key, create a remote path, create a Command Device, create the Differential Management-LU, start horcm instances B:Enable the TrueCopy option key, create a Command Device, create the Differential Management-LU, create a remote path, install Raid Manager CCI, start horcm instances C: Enable the TrueCopy option key, create a remote path, create a Command Device, install Raid Manager CCI, start horcm instances, create the Differential Management-LU D: Create a Command Device, create the Differential Management-LU, enable the TrueCopy option key, install Raid Manager CCI, start horcm instances, create a remote path Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=31 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 32 Which two operations must be performed when setting up a ShadowImage application? (Choose two) A: Define a Differential Management-LU B:Set up the ShadowImage pool with FC disks C: Choose the same controller for P-VOL and S-VOL D: Choose the same RAID level for P-VOL and S-VOL Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=32 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 33 12 You are setting up ShadowImage on an AMS500 What must you consider when creating the Command Device? A: The Command Device must always reside on a FC LUN B:The Command Device can run in a protected environment C: For backup purposes, two Command Devices must always be created D: The Command Device must reside on the same RAID Group as the Differential Management-LU Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=33 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 34 Which three statements correctly describe the function and usage of Copy-on-Write Snapshot software? (Choose three) A: Copy-on-Write Snapshot uses a pointer to access unaltered data on a P_VOL B:Copy-on-Write Snapshot allows using a V-VOL to restore a P_VOL when the data on the P_VOL is corrupted C: Copy-on-Write Snapshot performs copies using a pool volume to store all the pointers so the pool volume size is reduced D: It is a point-in-time copy feature that provides a virtual static image of data using less volume space and taking less time to create than ShadowImage EIt is a point-in-time copy feature that provides a static image of data using the same volume space as a P_VOL but taking less time to create than ShadowImage Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=34 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 35 Which two statements correctly describe the Differential Management-LU (DM-LU)? (Choose two) A: The DM-LU records the differential data between P_VOL and S_VOL B:There is a minimum of one and a maximum of two DM-LUs per array C: Three different DM-LUs are needed for managing TrueCopy, ShadowImage and Copy-on-Write Snapshot copy operations D: DM-LU is used for saving copy management information when an array is to be shutdown, and to restore the information back into the Cache after the array is restarted Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=35 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 36 13 Which two statements correctly describe the SNMP agent for an AMS/WMS storage system? (Choose two) A: The SNMP manager can block and isolate a failing HDD: B:The SNMP agent sends traps to the SNMP Manager to report hardware failures C: The SNMP agent can be used to shutdown an AMS/WMS storage subsystem remotely D: The SNMP agent has to be installed and activated on the AMS/WMS storage subsystem Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=36 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 37 The SNMP License Key is installed on an AMS200 storage system Which two configuration tasks must be performed on the AMS200 so it can report SNMP traps? (Choose two) A: Configure an SNMP Manager B:Load the MIB into the SMP Manager C: Configure the SNMP Manager s IP address D: Load the two configured environmental data files Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=37 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 38 When a failure occurs on an AMS/WMS storage subsystem, what type of SNMP traps does the array issue? A: Standard traps only B:Warning or alarm traps C: Standard or warning traps D: Standard or extended traps Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=38 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 39 Which three types of warning information can be obtained from an AMS/WMS storage system via SNMP traps? (Choose three) A: Path blockade B:Battery charging C: Spare drive blockade D: The ID of a failed drive ECache partial blockade 14 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=39 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 40 Which three statements correctly describe the Hi-Track feature? (Choose three) A: The HiTrack Monitor connects to port 6699 B:Hi-Track is installed by using a License Key C: HiTrack is included in every service contract D: Hi-Track can monitor storage devices and SAN switches EHi-Track uses put functionality when connected to an ftp agent Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HH0-005&qno=40 ------------------------------------------------------------------------------------------------------------------------------------- TwPass Certification Exam Features; - TwPass offers over 2500 Certification exams for professionals. More than 98,800 Satisfied Customers Worldwide. Average 99.8% Success Rate. Over 120 Global Certification Vendors Covered. Services of Professional & Certified Experts available via support. Free 90 days updates to match real exam scenarios. Instant Download Access! No Setup required. Price as low as $19, which is 80% more cost effective than others. Verified answers researched by industry experts. Study Material updated on regular basis. Questions / Answers are downloadable in PDF format. Mobile Device Supported (Android, iPhone, iPod, iPad) No authorization code required to open exam. Portable anywhere. Guaranteed Success. Fast, helpful support 24x7. View list of All Exams (AE); http://www.twpass.com/twpass.com/vendors.aspx Download Any Certication Exam DEMO. http://www.twpass.com/twpass.com/vendors.aspx To purchase Full version of exam click below; http://www.TwPass.com/