Preview only show first 10 pages with watermark. For full document please download

High Isolation Power Combiner Pbr-0006 Pbr0006

   EMBED


Share

Transcript

HIGH ISOLATION POWER COMBINER PBR-0006 Features     300kHz to 6 GHz Power Combiner 40 dB Typ Isolation Applications: IP3 Measurement and High Isolation Test Set-ups Microwave Power Dividers & Couplers App Note Electrical Specifications - Specifications guaranteed from -55 to +100°C, measured in a 50Ω system. Parameter Frequency Range Min Typ Nominal Power Splitting (dB) Max 6 Amplitude Balance (dB) ±0.6 ±1.2 1.5 3 Input Port VSWR 1.2 1.5 Common Port VSWR 1.3 1.8 Excess Insertion Loss (dB)1 300 kHz to 6 GHz Isolation (dB) 10 MHz to 6 GHz 33 40 300 kHz to 10 MHz 15 30 Power (W) 1 Weight (g) 40 1 Excess Insertion Loss = (Input Port to Common Port Insertion Loss) – 6 dB. Model Number Description PBR-0006 300 kHz – 6 GHz Power Combiner with SMA connectors 1 1 Default is SMA female connectors. Consult factory for other connector options. 2.60 .345 [66.04] [8.76] 2.04 .280 [51.82] [7.11] .375 [9.53] .068 [1.72] IN 2 .330 [8.38] POWER COMBINER (300 kHz - 6 GHz) D/C IN 1 .524 .660 [1.72] [16.76] PBR0006 COMMON Ø.093 Thru, 4 PL [2.36] SMA Female connectors, 3 PL PROJECTION INCH [MM] 1.30 [33.02] XXX=±.005 XX=±.02 .69 [17.53] 215 Vineyard Court, Morgan Hill, CA 95037 | Ph: 408.778.4200 | Fax 408.778.4300 | [email protected] 07/01/15 HIGH ISOLATION POWER COMBINER PBR-0006 Page 2 IP3 measurement using high isolation power combiner DUT (Mixer) RF Source 1 Power Combiner RF Source 2 R I L DUT (Amplifier) RF Source 1 Power Combiner Spectrum Analyzer Attenuator Spectrum Analyzer Attenuator RF Source 2 LO Source Fig. 1. Mixer IP3 measurement Fig. 2. Amplifier IP3 measurement 0 0 -3 -5 -6 Return Loss (dB) Insertion Loss (dB) Typical Performance -9 -12 -15 In 1 In 2 -18 -10 -15 -20 -25 -21 -30 0 1 2 3 4 Frequency (GHz) 5 6 0 1 2 3 4 Frequency (GHz) 5 6 Fig. 4. Return loss for input and common ports. Fig. 3. Input port to common port insertion loss. 3 0 2 -10 1 -20 Isolation (dB) Amplitude Balance (dB) Common In 1 In 2 0 -1 -30 -40 -50 -2 -60 -3 0 1 2 3 4 Frequency (GHz) 5 Fig. 5. Amplitude balance between input ports. 6 0 1 2 3 4 Frequency (GHz) 5 6 Fig. 6. Isolation between input ports. Marki Microwave reserves the right to make changes to the product(s) or information contained herein without notice. Marki Microwave makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does Marki Microwave assume any liability whatsoever arising out of the use of or application of any product. 215 Vineyard Court, Morgan Hill, CA 95037 | Ph: 408.778.4200 | Fax 408.778.4300 | [email protected] 07/01/15