Preview only show first 10 pages with watermark. For full document please download

High-performance Cmos Image Sensors

   EMBED


Share

Transcript

2016.10.12 EPIC Photonics Tech Watch @ micro photonics Messe Berlin “High-performance CMOS image sensors with the potentiality of medical applications” CEO : Satoshi Aoyama 2 Confidential About US We are “Professionals” for CMOS Image Sensor ! Standard Products Custom CIS Development & Sales 3 Confidential Company PROFILE • Established: – February 14, 2006 (Started as Brookman Lab, Inc.) • Chairman, CTO: – Shoji Kawahito (Professor of Shizuoka Univ.) • President , CEO: – Satoshi Aoyama Tokyo Chairman, CTO Dr. Shoji Kawahito Osaka • Office: Hamamatsu – 125 Daikumachi, Nakaku, Hamamatsu, 430-0936, Japan Confidential Topics 1. 8K(Ultrahigh-definition) Image Sensor for Endoscope 2. Ultrahigh-sensitivity Image Sensor for Bio Imaging 3. Time-Resolution CMOS Image Sensor for Fluorescence Lifetime Imaging 4 Confidential Topics 1. 8K(Ultrahigh-definition) Image Sensor for Endoscope 2. Ultrahigh-sensitivity Image Sensor for Bio Imaging 3. Time-Resolution CMOS Image Sensor for Fluorescence Lifetime Imaging 5 6 Confidential Topic 1 BT3300N “Full Spec” 8K Image sensor Confidential Topic 1 “8K” is the International Specification for UHDTV(Ultra High Definition Television) led by NHK(Japan broadcasting corporation) • HDTV – 2K resolution(1920×1080) • UHDTV1 – 4K resolution(3840×2160) • UHDTV2 – 8K resolution(7680×4320) 7 8 Confidential Topic 1 “8K spec” is NOT defined by following the roadmap of the high resolution competition for the sensor/camera, but is defined by the study of “Human Science” Confidential Topic 1 To get: “Sense of being there” and “Sensation of realness” Like being there Like watching a real object 9 10 Confidential Topic 1 33Mpix 120fps Full Spec SHV Sensor 2020 Tokyo 8K Broadcasting 2016 2011 2012 2013 2014 Rio 8K Test Broadcasting 11 Confidential Topic 1 • Specified in Rec. ITU-R BT.2020 Parameter Pixel count (Horizontal × vertical) Values 7680 × 4320 Bit depth 120, 60, & 59.94 Hz (Progressive) 12 & 10 bits Optical Format Pixel Pitch Data Rate Super 35mm 3.2um ~48 Gbps Frame frequency 12 Confidential Topic 1 Upper block V. Scan. (4336) ••• V. Scan. (4336) ••• ••• Pixel array 7808 (H)×4336 (V) Pixel array ••• Gain Amp. (7808/2) ••• ••• ADCs (7808/2) ••• Data readout circuit 488 Output of 96/2 LVDS drivers High-speed Low-power ADC 13 Confidential Topic 1 Column Parallel Cyclic A/D Converter for 8K Image Sensor Switch 1 Pixel in Vin1 Total 12 bits lSSCC2012, T. Watabe, et al. Confidential Topic 1 14 Confidential Topic 3 15 *) 8K Endoscope 3rd (Latest) Prototype 2nd Prototype 8K Endoscope *) Provision of data & pictures: MIC (Medical Imaging Consortium) => http://med-imaging.org Confidential Topic 1 *) 16 Clinical Trial with 8K Endoscope *) Provision of data & pictures: MIC (Medical Imaging Consortium) => http://med-imaging.org Confidential Topic 1 17 *) Clinical Trial with 8K Endoscope 8K Camera surgical appliance Keep the camera position and Looking down at the operation area Get Sufficient room for surgery !! *) Provision of data & pictures: MIC (Medical Imaging Consortium) => http://med-imaging.org Confidential Topic 1 18 *) Clinical Trial with 8K Endoscope Plane View An Electrically Zoomed image has still enough spatial resolution Electrical Zoomed Image Large space for Operation *) Provision of data & pictures: MIC (Medical Imaging Consortium) => http://med-imaging.org Confidential Topics 1. 8K(Ultrahigh-definition) Image Sensor for Endoscope 2. Ultrahigh-sensitivity Image Sensor for Bio Imaging 3. Time-Resolution CMOS Image Sensor for Fluorescence Lifetime Imaging 19 20 Confidential Topic 2 BT130C “Ultra Low Noise” & “Wide Dynamic Range” CIS with Folding Amplifier 21 Confidential Topic 2 <BT130C Feature> 22 Confidential Topic 2 “ High Intra-scene Dynamic Range ” Human Eye Can NOT see Bright Scene (White Out) BT130C:>80dB Can NOT see Dark Scene Or Noisy Image in Dark Scene Conventional High Sensitivity Sensor :~40dB General Sensor:~60dB Wide Dynamic Range Sensor:~100dB Bright 100K Clear Day In Summer 10K Shade In Clear Day 100 Cloudy Day 1 1K Conference Room 10 Evening Gloom Moon Light Night Sky 0.01 0.1 Lobby at Hotel Dark 1000K 10000K [lux] 23 Confidential Topic 2 Key Technologies Temporal Noise ADC Bit Resolution KeyTech (1) Low Noise Multiple Sampling Analog Gain (Integration) : ~ 1 e: ≧ 18bit [Ultrahigh Sensitivity] [Wide DRange] KeyTech (2) Variable-Resolution Column-Parallel Folding-Integration /Cyclic ADC 24 Confidential Topic 2 Folding Integrator Folding Integrator Folding Integrator Amp. Amp. Amp. ADC ADC ADC LOGIC LOGIC LOGIC 25 Confidential Topic 2 “Unique Analog Circuit” (Folding Integrator + A/D Convertor ) brings “Ultra-high Sensitivity” & “Wide Dynamic Range” M VOUT   VR  i   VS  i   i 1 26 Confidential Topic 2 Input-referred Noise [e-] # of Sampling vs Noise Number of Samplings 27 Confidential Topic 2 <17> “ Linear 18-bit Code ” has been extracted. <0> High Sensitivity Imaging High-sensitivity Camera (BT130C ) Eye observation image 29 Confidential Topic 2 Fluorescence microscope fluorescence micrograph captured by BT130C Confidential Topics 1. 8K(Ultrahigh-definition) Image Sensor for Endoscope 2. Ultrahigh-sensitivity Image Sensor for Bio Imaging 3. Time-Resolution CMOS Image Sensor for Fluorescence Lifetime Imaging 30 31 Confidential Topic 3 Rock-in Imaging ◆FLIM : Fluorescence Lifetime Imaging ◆TOF : Time-of-Flight Range Imaging Confidential Topic 3 32 *) CMOS FLIM Image Sensor At CMOS Photo Diode, High-speed Charge Transfer can be achieved. *) JSSCC,Vol.51-1,Jan2016, M.Seo, S.Kawahito, et al. Confidential Topic 3 *) 33 *) JSSCC,Vol.51-1,Jan2016, M.Seo, S.Kawahito, et al. Confidential Topic 3 *) 34 *) JSSCC,Vol.51-1,Jan2016, M.Seo, S.Kawahito, et al. Confidential Topic 3 *) 35 *) JSSCC,Vol.51-1,Jan2016, M.Seo, S.Kawahito, et al. Confidential Topic 3 36 **) Fluorescence Decaying in Cells (t=2.5ns(Hoechst), and t=10ns(Q-dot)) Heochst :nucleus Q-dot: cytoplasm **) Trans.ED, Oct 2012, Z.Li, S.Kawahito, et al. 37 Confidential Thank you for your attention. Please come over Hall :7.2c / Booth No.124 to talk about “Sensors” ! http://brookmantech.com