Transcript
2016.10.12 EPIC Photonics Tech Watch @ micro photonics Messe Berlin
“High-performance CMOS image sensors with the potentiality of medical applications”
CEO : Satoshi Aoyama
2
Confidential
About US
We are “Professionals” for CMOS Image Sensor ! Standard Products
Custom CIS Development & Sales
3
Confidential
Company PROFILE • Established:
– February 14, 2006 (Started as Brookman Lab, Inc.) • Chairman, CTO:
– Shoji Kawahito (Professor of Shizuoka Univ.) • President , CEO:
– Satoshi Aoyama Tokyo Chairman, CTO
Dr. Shoji Kawahito
Osaka
• Office:
Hamamatsu
– 125 Daikumachi, Nakaku, Hamamatsu, 430-0936, Japan
Confidential
Topics
1. 8K(Ultrahigh-definition) Image Sensor for Endoscope 2. Ultrahigh-sensitivity Image Sensor for Bio Imaging
3. Time-Resolution CMOS Image Sensor for Fluorescence Lifetime Imaging
4
Confidential
Topics
1. 8K(Ultrahigh-definition) Image Sensor for Endoscope 2. Ultrahigh-sensitivity Image Sensor for Bio Imaging
3. Time-Resolution CMOS Image Sensor for Fluorescence Lifetime Imaging
5
6
Confidential
Topic 1
BT3300N “Full Spec” 8K Image sensor
Confidential
Topic 1
“8K” is the International Specification for UHDTV(Ultra High Definition Television) led by NHK(Japan broadcasting corporation)
• HDTV – 2K resolution(1920×1080)
• UHDTV1 – 4K resolution(3840×2160)
• UHDTV2 – 8K resolution(7680×4320)
7
8
Confidential
Topic 1
“8K spec” is NOT defined by following the roadmap of the high resolution competition for the sensor/camera, but is defined by the study of
“Human Science”
Confidential
Topic 1
To get: “Sense of being there” and “Sensation of realness”
Like being there Like watching a real object
9
10
Confidential
Topic 1 33Mpix 120fps Full Spec SHV Sensor
2020
Tokyo 8K Broadcasting 2016
2011
2012
2013
2014
Rio 8K Test Broadcasting
11
Confidential
Topic 1
• Specified in Rec. ITU-R BT.2020 Parameter Pixel count (Horizontal × vertical)
Values 7680 × 4320
Bit depth
120, 60, & 59.94 Hz (Progressive) 12 & 10 bits
Optical Format Pixel Pitch Data Rate
Super 35mm 3.2um ~48 Gbps
Frame frequency
12
Confidential
Topic 1
Upper block
V. Scan. (4336)
•••
V. Scan. (4336)
••• •••
Pixel array 7808 (H)×4336 (V)
Pixel array
•••
Gain Amp. (7808/2)
•••
•••
ADCs (7808/2)
•••
Data readout circuit
488 Output of 96/2 LVDS drivers
High-speed Low-power ADC
13
Confidential
Topic 1
Column Parallel Cyclic A/D Converter for 8K Image Sensor Switch 1 Pixel in Vin1
Total 12 bits lSSCC2012, T. Watabe, et al.
Confidential
Topic 1
14
Confidential
Topic 3
15
*)
8K Endoscope 3rd (Latest) Prototype
2nd Prototype
8K Endoscope
*) Provision of data & pictures: MIC (Medical Imaging Consortium) => http://med-imaging.org
Confidential
Topic 1
*)
16
Clinical Trial with 8K Endoscope
*) Provision of data & pictures: MIC (Medical Imaging Consortium) => http://med-imaging.org
Confidential
Topic 1
17
*)
Clinical Trial with 8K Endoscope 8K Camera
surgical appliance
Keep the camera position and Looking down at the operation area
Get Sufficient room for surgery !!
*) Provision of data & pictures: MIC (Medical Imaging Consortium) => http://med-imaging.org
Confidential
Topic 1
18
*)
Clinical Trial with 8K Endoscope Plane View
An Electrically Zoomed image has still enough spatial resolution
Electrical Zoomed Image
Large space for Operation *) Provision of data & pictures: MIC (Medical Imaging Consortium) => http://med-imaging.org
Confidential
Topics
1. 8K(Ultrahigh-definition) Image Sensor for Endoscope 2. Ultrahigh-sensitivity Image Sensor for Bio Imaging
3. Time-Resolution CMOS Image Sensor for Fluorescence Lifetime Imaging
19
20
Confidential
Topic 2
BT130C “Ultra Low Noise” & “Wide Dynamic Range” CIS with Folding Amplifier
21
Confidential
Topic 2
<BT130C Feature>
22
Confidential
Topic 2
“ High Intra-scene Dynamic Range ” Human Eye
Can NOT see Bright Scene (White Out)
BT130C:>80dB
Can NOT see Dark Scene Or Noisy Image in Dark Scene
Conventional High Sensitivity Sensor
:~40dB General Sensor:~60dB Wide Dynamic Range Sensor:~100dB
Bright
100K Clear Day In Summer
10K Shade In Clear Day
100
Cloudy Day
1
1K Conference Room
10 Evening Gloom
Moon Light
Night Sky
0.01
0.1
Lobby at Hotel
Dark
1000K
10000K [lux]
23
Confidential
Topic 2
Key Technologies Temporal Noise ADC Bit Resolution KeyTech (1)
Low Noise Multiple Sampling Analog Gain (Integration)
: ~ 1 e: ≧ 18bit
[Ultrahigh Sensitivity] [Wide DRange] KeyTech (2)
Variable-Resolution Column-Parallel Folding-Integration /Cyclic ADC
24
Confidential
Topic 2
Folding Integrator
Folding Integrator
Folding Integrator
Amp.
Amp.
Amp.
ADC
ADC
ADC
LOGIC
LOGIC
LOGIC
25
Confidential
Topic 2
“Unique Analog Circuit” (Folding Integrator + A/D Convertor ) brings
“Ultra-high Sensitivity” & “Wide Dynamic Range”
M
VOUT VR i VS i i 1
26
Confidential
Topic 2
Input-referred Noise [e-]
# of Sampling vs Noise
Number of Samplings
27
Confidential
Topic 2 <17>
“ Linear 18-bit Code ” has been extracted.
<0>
High Sensitivity Imaging
High-sensitivity Camera (BT130C )
Eye observation image
29
Confidential
Topic 2
Fluorescence microscope
fluorescence micrograph captured by BT130C
Confidential
Topics
1. 8K(Ultrahigh-definition) Image Sensor for Endoscope 2. Ultrahigh-sensitivity Image Sensor for Bio Imaging
3. Time-Resolution CMOS Image Sensor for Fluorescence Lifetime Imaging
30
31
Confidential
Topic 3
Rock-in Imaging ◆FLIM : Fluorescence Lifetime Imaging
◆TOF : Time-of-Flight Range Imaging
Confidential
Topic 3
32
*)
CMOS FLIM Image Sensor
At CMOS Photo Diode, High-speed Charge Transfer can be achieved.
*) JSSCC,Vol.51-1,Jan2016, M.Seo, S.Kawahito, et al.
Confidential
Topic 3
*)
33
*) JSSCC,Vol.51-1,Jan2016, M.Seo, S.Kawahito, et al.
Confidential
Topic 3
*)
34
*) JSSCC,Vol.51-1,Jan2016, M.Seo, S.Kawahito, et al.
Confidential
Topic 3
*)
35
*) JSSCC,Vol.51-1,Jan2016, M.Seo, S.Kawahito, et al.
Confidential
Topic 3
36
**)
Fluorescence Decaying in Cells (t=2.5ns(Hoechst), and t=10ns(Q-dot))
Heochst :nucleus Q-dot: cytoplasm
**) Trans.ED, Oct 2012, Z.Li, S.Kawahito, et al.
37
Confidential
Thank you for your attention.
Please come over
Hall :7.2c / Booth No.124 to talk about “Sensors” !
http://brookmantech.com