NH12-120W HIGHHigh RATE DISCHARGE BATTERY rate discharge battery Rechargeable Products Sealed Lead Acid Battery NH12-120W NH12-120W www.npbattery.com NH 12 General Features      Positive and negative plates in lead-calcium tin alloy. Superior energy density Operates at a low internal pressure. Gas Recombination. Usable in any orientation.      A recognized component of UL. Very high power output. Application specific designs. Six months shelf life at 20℃. Design life 10 years. Dimensions Length Width Height Total Height Approx.Weight SI Units 165mm 125mm 175mm 175mm 8.8Kg English Units 6.50inch 4.92inch 6.89inch 6.89inch 19.4lbs Performance Characteristics 165±1  Nominal Voltage: 12V  Number of cell: 6  Nominal Capacity77°F(25℃):15 min Wattage @1.67V 120W/cell  Nominal Capacity 77°F(25℃):10 hour rate (2.7A,10.8V) 27Ah  Internal Resistance:Fully Charged battery 68°F(20℃) 7.5mΩ  Self-Discharge:3% of capacity declined per month at 20℃  Operating Temperature Range: Discharge -20~60℃ Charge -10~60℃ Storage -20~60℃  Max. Discharge Current 68°F(20℃):420A (5S)  Short Circuit Current:800A  Charge Methods:Constant Voltage Charge 68°F(20℃) Cycle use: 14.5 ~ 14.9V Maximum charging current 7A NH12-120W Standby use: 13.6 ~13.8V Rechargeable Products Sealed Lead Acid Battery 4 Terminal(F13) M5 Unit:mm Discharge Date Not restricted for air transport-complies with IATA/ICAO special provision A67 End Voltage Per cell/V 1.60 10min 86.0 Constant Current Discharge Date(Amperes at 25℃) ANDA-OLSEN AS NO-6018 Aalesund Tel +47 70 17 89 70 [email protected] Blindheim Industrivei 47 Norway Fax +47 70 17 89 71 www.anda-olsen.no 15min 20min ANDA-OLSEN 25min 30min 35min 50min 55minAalesund 1h 1.5h 2h Tel2.5h+47 3h [email protected] 7h 8h 9h 10h AS 40min 45min NO-6020 70 17 4h89 705h Blindheim Industrivei 2e Norway Fax +47 70 17 89 71 www.anda-olsen.no 68.0 54.0 47.0 42.0 35.8 33.0 30.2 27.0 24.9 23.1 16.3 12.8 10.5 9.10 6.95 5.65 4.75 4.15 3.65 3.20 2.95 20h 1.65 120W  Charge Methods:Constant Voltage Charge 68°F(20℃) Cycle use: 14.5 ~ 14.9V Maximum charging current 7A NH12-120W Standby use: 13.6 ~13.8V Rechargeable Products Sealed Lead Acid Battery NH12-120W 4 HIGH RATE DISCHARGE BATTERY NH 12 120W M5 Unit:mm Discharge Date Constant Current Discharge Date(Amperes at 25℃) End Voltage 10min 15min 20min 25min 30min 35min 40min 45min 50min 55min 1h 1.5h 2h 2.5h 3h 4h 5h 6h 7h 8h 9h 10h 20h 1.60 86.0 68.0 54.0 47.0 42.0 35.8 33.0 30.2 27.0 24.9 23.1 16.3 12.8 10.5 9.10 6.95 5.65 4.75 4.15 3.65 3.20 2.95 1.65 1.65 82.5 65.5 52.5 45.3 40.6 34.4 31.8 29.2 26.1 24.0 22.3 15.8 12.4 10.3 8.90 6.80 5.50 4.60 4.05 3.55 3.15 2.90 1.65 1.70 79.0 63.0 50.5 43.5 39.0 34.0 30.5 28.0 25.0 23.0 21.5 15.2 12.0 10.0 8.70 6.60 5.35 4.50 3.90 3.45 3.10 2.85 1.60 1.75 75.5 60.5 48.5 41.7 37.4 32.6 29.2 26.8 23.9 22.0 20.7 14.6 11.6 9.75 8.50 6.40 5.20 4.40 3.75 3.35 3.05 2.80 1.55 1.80 71.5 57.5 46.0 39.8 35.7 31.0 27.8 25.5 22.7 20.8 19.9 13.9 11.1 9.40 8.30 6.15 5.00 4.20 3.60 3.20 2.95 2.70 1.50 Per cell/V Constant Power Discharge Date(Watts per cell at 25℃) End Voltage 10min 15min 20min 25min 30min 35min 40min 45min 50min 55min 1h 1.5h 2h 2.5h 3h 4h 5h 6h 7h 8h 9h 10h 1.60 165 128 98.0 81.5 73.5 63.5 58.5 54.3 50.2 46.0 43.5 30.5 25.0 20.1 17.6 14.1 11.7 9.85 8.50 7.45 6.70 6.05 5.25 1.65 158 123 95.0 79.0 71.5 61.8 56.8 52.7 48.7 44.7 42.1 29.5 24.0 19.4 17.1 13.7 11.4 9.60 8.30 7.30 6.55 6.00 5.20 1.67 154 120 93.5 78.0 70.5 61.0 56.0 52.0 48.0 44.0 41.5 29.0 23.5 19.0 16.8 13.5 11.2 9.50 8.20 7.20 6.50 5.95 5.15 1.70 151 118 91.5 77.5 69.5 60.8 55.0 51.0 47.1 43.2 40.7 28.3 23.0 18.6 16.5 13.2 11.0 9.30 8.05 7.10 6.40 5.90 5.10 1.75 144 113 88.0 75.0 67.5 58.6 53.2 49.2 45.5 41.7 39.3 27.1 22.0 17.8 15.9 12.7 10.6 9.00 7.80 6.90 6.25 5.80 5.05 1.80 136 107 84.5 72.0 65.0 56.2 51.2 47.2 43.7 40.0 37.7 25.7 20.8 17.0 15.2 12.1 10.2 8.65 7.50 6.65 6.05 5.70 5.00 (rCA) 120 0.25 100 0.20 100 (V) 15.0 ume Charged vol 14.0 80 0.15 60 15 120 Capacity(%) (%) 12h Temperature effects on float life Cycle service life in relation to depth of discharge Constant voltage charging characteristic (0.25CA,25℃) Voltage Current Charged Volume charge characteristic curve Charge voltage 13.0 80 60 100%D.O.D 30% Depth of discharge 50%D.O.D 40 Life(years) Per cell/V 2.30V/cell 10 5 0.10 40 20 0 12.0 20 0.05 11.0 0 Charging current 0 0 2 4 6 8 10 12 14 16 18 Charging time(hours) 20 0 200 400 600 800 1000 Number of cycles(cycles) 1200 1400 10 20 30 40 50 Temperature(℃) Breivika Industrivei 47, 6018 Aalesund, Norway ANDA-OLSEN AS NO-6018 Aalesund Tel +47 70 17 89 70 [email protected] 17 89 70. Fax +47 70 17 89 71 Anda-Olsen AS ANDA-OLSEN Tel 17 +47 70 +47 70 [email protected] Blindheim Industrivei AS 47 Norway NO-6020 AalesundFax +47 70 8970 7117 89Tel. www.anda-olsen.no [email protected] www.anda-olsen.no Blindheim Industrivei 2e Norway Fax +47 70 17 89 71 www.anda-olsen.no