Preview only show first 10 pages with watermark. For full document please download

High Speed Internet Meeting Room Information Packet

   EMBED


Share

Transcript

Information Technology High Speed Internet Meeting Room Information Packet Steve Lui, Area Director of IT [email protected] – (415)202-7782 Kathy Penick, Director of Telecommunications [email protected] – (415)923-5061 Overview_________________________________________________ The Hilton San Francisco has the most updated, state of the art network in our meeting space than any other hotel in the city. We rebuilt our network infrastructure from scratch in 2007 and completed the multi-million dollar project in mid-2008. All ballrooms and meeting rooms are connected through a fiber optic backbone, without CAT5 “daisy chaining” between closets. Each switch is connected to the core switch with a minimum of a 1GB fiber link. All of our data connections in the meeting rooms are fully certified CAT6 cabling and run at 10/100/1000 speeds. Wireless connectivity is also available in every meeting space with systems in place to dynamically handle interference and large density. At the Hilton San Francisco, you will not have to deal with a third party or an offsite company working on commission. We built, own, and manage our network infrastructure, which means that you will have the highest level of support, service, and flexibility. Data Circuit__________________________________________ We are proud to offer a dedicated, full DS3 circuit to our meeting space customers. We do not “share” our circuit with the guest room internet so you can be assured that you are not competing with unknown guestrooms for bandwidth. We also have a redundant T1 line, just in case. Our Tier 1 internet provider is Level 3 Communications. Core Switch_______________________________________________ Our Cisco Catalyst 4507 Core Switch has a 24 Gbps full duplex backplane delivering the highest level of performance and availability. In addition, we have redundant Supervisor Engine IV cards to provide dynamic failover and redundant power supplies. Fiber Optic Network_______________________________________ Our fiber optic network backbone infrastructure is made up of fully certified multi-mode 62.5 micron fiber optic cabling connecting all of our meeting room closet switches to our Cisco 4507 Core Switch via a minimum of 1Gbps speeds. Copper Wired Connections_________________________________ We use fully certified, CAT6 copper cabling capable of speeds in excess of 1 Gbps for all of our hard wired ports in all of our meeting space. The CommScope SYSTIMAX GigaSPEED XL ethernet cables are one of the highest rated in the industry, meeting and exceeding all CAT6 standards. Closet Switches___________________________________________ Our closet switches have 10/100/1000 Cisco managed access switches that all have fiber uplink ports that connect to our Cisco 4507 Core. All of our copper ports are Power Over Ethernet (PoE) capable. Wireless Connectivity______________________________________ We use a combination of Cisco Autonomous managed Access Points as well as the Cisco Wireless Controller in our larger rooms to handle dynamic channeling, interference and power management. Our wireless network is 802.11b/g capable. VLAN Capability___________________________________________ We have multiple trunked VLAN’s that we can utilize to connect meeting rooms from any part of the hotel to another meeting room so you can have flexibility in the things that you need to achieve for your meeting. Port ID’s__________________________________________________ All network ports in the meeting rooms are designated by a GREEN jack. The blueprints in this packet show the locations of all data ports, allowing you to plan for connectivity locations in the room. = represents data ports, while = represents ports already connected to a wireless access point. Static IP Addresses_________________________________________ We will be happy to provide you with a public static address if you require one for a device that might require one. Please contact Steve Lui or Kathy Penick for assistance with a public address. Most VPN’s do not have a problem working with a private address on our network. Yosemite Room YOS/A – 1,2 YOS/B – 1,2 YOS/B – 3,4 Yosemite Room YOS/B – 5 YOS/A – 3,4 YOS/A – 5,6 YOS/B – 6 YOS/B – 9,10 Room A YOS/B Fiber Tie to Core Switch YOS/B – 7,8 Room B YOS/A – 9,10 YOS/A - 19 Room C * YOS/A – 7,8 YOS/A - 11,12 YOS/A – 13,14 YOS/A Fiber Tie to Core Switch YOS/A - 17 EXECUTIVE BOARD ROOM YOS/A - 15,16 YOS/A - 18 YOS/B - 13 YOS/B - 11,12 Tower 3, 6th Floor 6/A - 4,5 6/A - 1 6/A - 2 6/A - 3 (4) 6/B - 1,2 (1) 6/B - 3 Tower 3, 5th Floor 6/A: 1-5 Copper Tie to 6/B 6/B: 1-3 Fiber Tie to Core Switch Union Square Rooms Union Sq. 1 Union Sq. 2 Union Sq. 3 Union Sq. 4 US/A: 1-4 US/A: 5-8 US/A: 9-12 US/A:13-16 WOMEN MEN Union Sq. 5 Union Sq. 6 US/A:17-20 US/A: 21-24 (13) (96) (7) Union Sq. 7 US/A: 25-28 (26) US/A, CAL/A, WC/A, CON Fiber Tie to Core Switch (88) (39) Union Square 22 US/A: 85-88 Union Sq. 23 US/A: 89-92 Homaco Room (74) US/A: 77-80 Union Sq. 20 US/A: 73-76 Union Sq. 19 (66) US/A: 69-72 US/A: 65-68 Union Sq. 18 Union Sq. 17 (59) US/A: 61-64 Union Sq. 16 US/A: 57-60 Union Sq. 15 US/A: 53-56 Union Sq. 14 Union Sq. 13 US/A: 49-52 (50) (81) US/A: 81-84 Union Square 21 Union Sq. 8 Union Sq. 9 Union Sq. 10 Union Sq. 11 Union Sq. 12 US/A: 29-32 US/A: 33-36 US/A: 37-40 US/A: 41-44 US/A: 45-48 Union Sq. 24 US/A: 93-96 Union Square 25 US/A: 97-100 (98) Plaza and Executive Rooms EX/A Fiber Tie to Core Switch PLZ/A - 5 PLZ/A - 6 PLZ/A – 7,8 PLZ/A Fiber Tie to Core Switch PLZ/A – 9,10 EX/A - 6 PLZ/A – 3,4 Presidio PLZ/A – 1,2 EX/A - 8 Marina Plaza Room B Seacliff EX/A – 9,10 Lobby EX/A - 4 EX/A - 3 PLZ/A – 11,12 EX/A - 12 Sunset West Concourse PLZ/A – 13,14 Plaza Room A PLZ/B - 8 PLZ/B – 5,6 PLZ/B - 7 EX/A - 7 EX/A - 5 PLZ/B – 1,2 EX/A - 2 PLZ/B – 3,4 EX/A - 1 Tower 1 Elevator Lobby Promenade PLZ/B Fiber Tie to Core Switch EX/A – 11 Imperial Ballroom and Franciscan Room IMP/B Fiber Tie to Core Switch IMP/A – 13,14 FRAN/A Fiber Tie to Core Switch FRN/A: 5-8 IMP/A – 15,16 FRN/A - 1 IMP/A – 11,12 IMP/B – 7,8 FRN/A: 9-12 IMP/A - 10 IMPERIAL BALLROOM IMP/A - 9 IMPERIAL BALLROOM A B IMP/A – 7,8 IMP/B – 5 IMP/B – 6 IMP/A – 5,6 IMP/A – 3,4 Lobby FRANCISCAN ROOM IMP/A Fiber Tie to Core Switch FRN/A - 2 FRN/A: 13-16 FRN/A - 3 IMP/B – 3,4 IMP/A – 1,2 FRN/A - 4 FRN/A: 17-20 Garden Lane IMP/B – 1,2 Elevator Lobby Grand Ballroom GB/B 27,28 GREEN ROOM GB/B 29 GB/B 25,26 GB/B Fiber Tie to Core Switch GB/B 19,20 GB/B 15,16 GB/C 5,6 GB/C 3,4 GB/C Fiber Tie to Core Switch GB/C 9,10 GB/C 7,8 GB/C 13,14 GB/C 11,12 GB/B 17,18 GB/B 3,4 GB/B 21,22 GB/B 7,8 GB/B 23,24 GB/B 9,10 GB/B 5,6 GB/B 1,2 GB/B 11,12 GB/C 1,2 GB/C 15 GB/C 16 GB/C 17 GB/C 18 GB/B 13,14 GB/D 15,16 GB/C 19 GB/D 17 * GB/D 13,14 GB/D 18 GB/D 19 GB/A 13,14 GB/D 20 GB/D 12 GB/D Fiber Tie to Core Switch GB/D 11,12 GB/D 9,10 GB/D 7,8 GB/D 3,4 GB/D 5,6 GB/D 1,2 GB/A 1,2 GB/A 3,4 GB/A 5,6 GB/A 7,8 GB/A 9,10 GB/A 11,12 GB/A Fiber Tie to Core Switch Continental Ballroom CAL/A - 5 CAL/A - 6 West Corridor WC/A - 1 WC/A: 2-5 CAL/A - 1 CON 59,60 CON 48,49 CON 67,68 South Corridor CON 72 CON 74 CON 69 CON 70,71 CON 53 CON 56,57 CON 58 CON 55 CON 63 Ballroom #1 CON 75 CON 61,62 CON 65,66 Ballroom #9 CON 64 CON 73 *CON 44 CON 54 CON 43 CONTINENTAL BALLROOM CON 45,46 CON 47 CAL/A – 3,4 CAL/A - 2 CON - 41,42 Ballroom #6 Ballroom #4 Ballroom #2 * Ballroom #8 Ballroom #5 CON 35,36 CON 32,33 CON 30,31 CON 52 CON 26,27 CON 24,25 CON 21,22 CON 17 CON 40 Ballroom #3 CON 39 CON - 29 CON 37 CON - 34 CON 18 CON 20 CON - 23 CON - 15 CON - 14 East Corridor CON – 7,8 Ballroom #7 CON - 28 CON 38 CON - 16 CON - 5,6 CON 50, 51 North Corridor WC/A - 6 CON 19 CON 11,12 CON - 13 CON - 3,4 CON - 9 CON - 10 CON - 1,2 Golden Gate Rooms GG/A – 21* GG/A Fiber Tie to Core Switch GG/A – 22 GG/A – 23 * GG/A – 1,2 GG/A – 9,10 GG/A – 3,4 GG/A – 5,6 GG/A – 11,12 GG/A – 7,8 GG/B – 35,36 GG/B – 37,38 GG/A – 15,16 GG/B – 1,2 GG/A – 17,18 GG/B – 3,4 GG/A – 19,20 GG/B – 5,6 GG/B – 39,40 GG/B – 7,8 GG/B – 9,10 GG/B – 11,12 GG/B – 13,14 GG/B – 15,16 GG/B – 17,18 GG/B – 19,20 GG/B – 21,22 GG/B – 43,44 GG/B – 23,24 GG/B – 31,32 GG/B – 25,26 GG/B – 27,28 GG/B – 62 GG/A – 63* GG/B – 45,46 * GG/B – 60 GG/B – 49,50 GG/B – 47,48 GG/B – 51,52 GG/B – 53,54 GG/B – 29,30 GG/B – 64 GG/B Fiber Tie to Core Switch GG/B – 41,42 GG/B – 33,34 Meeting Space HSIA Network Hilton San Francisco Meeting Space HSIA Network 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 AirTight Wireless Intrusion Detection CATALYST 3550 1 2 SYSTEM RPS STAT UTIL DUPLEX SPEED GB/D Closet 3 5 7 9 11 13 15 17 19 21 1 2 4 6 8 10 12 14 16 18 20 22 PS1 ALARM PS2 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 CATALYST 3550 2 LINK ACT UTILITY 1 MODEL 4402 50 AP 2 US/A1 48 Port Cisco 4402 Wireless Controller Primary CATALYST 3550 23 2 SYSTEM RPS STAT UTIL DUPLEX SPEED 3 2 1 STAT UTIL DUPLEX SPEED WIRELESS LAN CONTROLLER ACT LINK STATUS CONSOLE SERVICE 1 1 SYSTEM RPS Cisco 4400 Series ACT LINK 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 CATALYST 3550 24 1 2 SYSTEM RPS STAT UTIL DUPLEX SPEED GB/C Closet 1 3 5 7 9 11 13 15 17 19 21 To C CATALYST 3550 23 1 2 To C SYSTEM RPS STAT UTIL DUPLEX SPEED 2 4 6 8 10 12 14 16 18 20 22 24 GB/A Closet 1 3 5 7 9 11 13 15 17 19 21 To C CATALYST 3550 23 1 2 SYSTEM RPS STAT UTIL DUPLEX SPEED 2 4 6 8 10 12 14 16 18 20 22 24 1 3 5 7 9 11 13 15 17 19 21 23 CATALYST 3550 1 2 SYSTEM RPS STAT UTIL DUPLEX SPEED 2 4 6 8 10 12 14 16 18 20 22 o re To C o 24 GB/B Closet (2 Switches) To Core re Po o re Cisco 4400 Series WIRELESS LAN CONTROLLER ACT LINK o re Po rt Por t 5/2 rt 4/2 ACT LINK STATUS PS1 ALARM PS2 LINK ACT CONSOLE SERVICE Po rt UTILITY 1 MODEL 4402 50 AP 2 Cisco 4402 Wireless Controller Secondary 5/3 To Switch must be in off "O" position to Install/Remove power supply. Fastener must be fully enaged prior to operating power supply. Switch must be in off "O" position to Install/Remove power supply. Fastener must be fully enaged prior to operating power supply. 4/3 INPUT OK INPUT OK FAN OK FAN OK OUTPUT FAIL OUTPUT FAIL INPUT 100-240 V~ 12-5 A 50/60 Hz INPUT 100-240 V~ 12-5 A 50/60 Hz 1300ACV 1300ACV WS-X4014 Port 4/1 UPLINK 1 1 UPLINK 2 UTILIZATION CONSOLE 10/100 MGT FLASH RESET FLASH RESET STATUS Catalyst 4507 1% SUPERVISOR III ENGINE LINK ACTIVE LINK 100% EJECT ACTIVE WS-X4014 UPLINK 1 2 UPLINK 2 UTILIZATION CONSOLE 10/100 MGT STATUS 1% SUPERVISOR III ENGINE LINK ACTIVE LINK 100% r Co o rt eP 4/1 2 US/A2 CATALYST 3550 1 2 SYSTEM RPS 3 4/1 STAT UTIL DUPLEX SPEED 5 4/1 rt Po o rt o re o re P C o C T To /14 o rt 4 o re P C o T /5 o rt 4 o re P To C US/A3 CATALYST 3550 1 2 SYSTEM RPS STAT UTIL DUPLEX SPEED US/CAL/WC 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 CATALYST 3550 1 2 SYSTEM RPS STAT UTIL DUPLEX SPEED IMP/A Closet EJECT ACTIVE WS-X4418-GB WS-X4424-GB-RJ45 MULTI-SPEED GIGABIT ETHERNET SWITCHING MODULE 24 PORT 10/100/1000 BASE-T 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 CATALYST 3550 1 2 SYSTEM RPS STAT UTIL DUPLEX SPEED 3 STATUS 1 2 1000 BASE-X SWITCHING MODULE WS-X4418-GB 4/4 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 1 3 4 1 2 5 6 3 7 8 4 1 0 9 5 6 1 1 7 1 2 8 1 3 9 1 4 10 1 5 1 6 11 1 7 12 1 8 13 1 9 14 2 0 15 2 1 16 2 2 2 3 17 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 IMP/B Closet 5 STATUS CATALYST 3550 1 2 To Core Port 5/4 YOS/B Closet 1000 BASE-X SWITCHING MODULE To Core 6 7 To Core FAN STATUS Cisco 4507 Core Switch 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 CATALYST 3550 1 2 SYSTEM RPS STAT UTIL DUPLEX SPEED Franciscan Closet 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 To Core o To C rt 4 re Po 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 CATALYST 3550 1 2 SYSTEM RPS Continental Homaco #5 1 3 5 7 9 11 13 15 17 19 21 CATALYST 3550 23 1 2 SYSTEM RPS STAT UTIL DUPLEX SPEED 2 4 6 8 10 12 14 16 18 20 22 24 Continental Homaco #6 1 3 5 7 9 11 13 15 17 19 21 CATALYST 3550 23 1 2 SYSTEM RPS STAT UTIL DUPLEX SPEED 2 4 6 8 10 12 14 16 18 20 22 24 Continental Homaco #7 1 3 5 7 9 11 13 15 17 19 21 CATALYST 3550 23 1 2 SYSTEM RPS STAT UTIL DUPLEX SPEED 2 4 6 8 10 12 14 16 18 20 22 24 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 4 o rt eP 3 5 7 9 11 13 15 17 19 21 23 4 6 8 10 12 14 16 18 20 22 24 13 15 17 19 21 23 12 14 16 18 20 22 24 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 CATALYST 3550 2 CATALYST 3550 2 o re Por t4 PLAZA/B Closet /16 or CATALYST 3550 1 2 SYSTEM RPS Golden Gate B-3 (Closet 139) 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 CATALYST 3550 1 2 SYSTEM RPS To Allot NetEnforcer Bandwidth Monitoring Box 6/B Closet Co re Po r t5 /5 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 CATALYST 3550 1 2 SYSTEM RPS STAT UTIL DUPLEX SPEED 6/A Closet Cisco 7200 Series VXR 3 ATM 1A-T3 4 ATM 0 TX FERF OOF 1 FE-PRI 1FE-2CE1-BU RX AIS RCLK EN CTRLR 1 2 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 CATALYST 3550 1 10/100BASE-T CTRLR 0 2 SYSTEM RPS EN STAT UTIL DUPLEX SPEED 0 Golden Gate A (Closet 113) Cisco 7200 VXR Router 2 Golden Gate B-2 (Closet 139) 2 11 10 PLAZA/A Closet STAT UTIL DUPLEX SPEED STAT UTIL DUPLEX SPEED CATALYST 3550 1 1 9 8 Port 4/9 /18 SYSTEM RPS STAT UTIL DUPLEX SPEED 7 6 1 To C Golden Gate B-1 (Closet 139) STAT UTIL DUPLEX SPEED 5 4 SYSTEM RPS /7 7 4/1 o rt P 0 re 4/1 Co o rt To P re Co To 6 5/1 rt 7 o 5 /1 eP rt or o 8 C eP 5/1 To or rt o C P To re Co o T C To 1 3 2 1 2 Executive Conf Center Closet STAT UTIL DUPLEX SPEED 1 SYSTEM RPS STAT UTIL DUPLEX SPEED CATALYST 3550 1 SYSTEM RPS STAT UTIL DUPLEX SPEED Port 4/8 Port 4/6 COLL 11 FDX 9 LINK 7 100 Mbps 5 REMOTE ALARM LOCAL ALARM LOOP BACK CARRIER DETECT 3 REMOTE ALARM LOCAL ALARM LOOP BACK CARRIER DETECT 1 STAT UTIL DUPLEX SPEED To Core Port 5/1 STATUS 1000 BASE-X SWITCHING MODULE WS-X4418-GB 2 SYSTEM RPS 2 4 18 4 YOS/A Closet 1 SYSTEM RPS STAT UTIL DUPLEX SPEED CATALYST 3550 STATUS To Core Port Level 3 DS3 Circuit Internet