Preview only show first 10 pages with watermark. For full document please download

High Voltage Spiral Rectifiers – Cjv04, Cjv05, Cjv06, Cj2v Series

   EMBED


Share

Transcript

HIGH VOLTAGE SPIRAL RECTIFIERS – CJV04, CJV05, CJV06, CJ2V SERIES FIGURE 52 1.0” Ref. A H CJV04H*S Average Forward Current Max @ 50°C Ambient Average Forward Current Max @ 50°C (Forced Air 300ft/min) Maximum Surge Current, 10ms Sine Pulse CJV05H*S Average Forward Current Max @ 50°C Ambient Average Forward Current Max @ 50°C (Forced Air 300ft/min) Maximum Surge Current, 10 ms Sine Pulse CJV06H*S Average Forward Current Max @ 50°C Ambient Average Forward Current Max @ 50°C (Forced Air 300ft/min) Maximum Surge Current, 10 ms Sine Pulse Height H=3.70” max 6.5 Amps 12.5 Amps 370 Amps Height H=3.70” max 10.0 Amps 22.0 Amps 800 Amps Height H=3.70” max 12.0 Amps 24.0 Amps 1200 Amps IFAVM IFAVM IFSM IFAVM IFAVM IFSM IFAVM IFAVM IFSM *- Number of modules 16 20 24 28 32 Length A (Inches) 7.375 8.50 9.625 10.75 11.875 Maximum Operating Peak Voltage 8KV 10KV 12KV 14KV 16KV VF @ IFAVM @ 25°C 16 20 24 28 32 Maximum Operating and Storage Temperature TA Maximum Reverse Leakage Current @ operating voltage @ TJ=25°C, less than 100 micro amps 36 13.00 18KV 36 40 44 14.125 15.25 20KV 22KV 40 44 -40°C to 125°C 48 16.375 24KV 48 FIGURE 100 4.5 Approx. ∅13/64 1.0 2.0 DIODES A CJ2V04H*S Average Forward Current Max @ 50°C Ambient Average Forward Current Max @ 50°C (Forced Air 300ft/min) Maximum Surge Current, 8.3ms Sine Pulse CJ2V06H*S Average Forward Current Max @ 50°C Ambient Average Forward Current Max @ 50°C (Forced Air 300ft/min) Maximum Surge Current, 8.3 ms Sine Pulse 1.0” Ref. .75 1.0 .75 Height H=3.70” max 3.25 Amps 6.25 Amps 370 Amps Height H=3.70” max 6.0 Amps 12.0 Amps 1500 Amps IFAVM IFAVM IFSM IFAVM IFAVM IFSM *- Number of modules 16 20 24 32 Length A (Inches) 5.125 5.625 6.250 7.375 Maximum Operating Peak Voltage 8KV 10KV 12KV 16KV VF @ IFAVM @ 25°C 16 20 24 32 Maximum Operating and Storage Temperature TA Maximum Reverse Leakage Current @ operating voltage @ TJ=25°C, less than 100 micro amps 2.0 36 7.875 18KV 36 40 48 8.500 9.625 20KV 24KV 40 48 -40°C to 120°C 56 10.725 28KV 56 Note: 1 The true PIV of an MOV compensated unit is 2X the operating voltage. Note: 2 Each diode is rated @ 1000 volt minimum and MOV compensated which gives an avalanche rating of 90 joules maximum (8x20 microsec) and a Vnominal of 680 volts. For R-C compensation, drop the “S” suffix. Higher Voltages, Higher Surge Currents, Fast Recovery, Custom Lengths, and doubler assemblies available. Please Consult the Factory. Note: Each diode is MOV compensated. 31 CKE Mailing Address: P.O. Box 848 ■ Farmingdale, NJ 07727 ■ Telephone: (724) 479-3533 ■ Fax: (724) 479-3537 ■ www.cke.com