Transcript
HighLight 1000FL 1 kW Industrial OEM Fiber Laser
HighLight 1000FL Features: Coherent HighLight 1000FL is a compact 1 kW OEM fiber laser for use in materials processing applications. It is designed for cutting and welding of metals, as well as for additive metal manufacturing applications such as laser cladding or 3-D printing.
• OEM fiber laser with 1 kW output power
The modular design of this fiber laser is ideal for OEMs and greatly enhances serviceability of this product. The included DC power supply allows for ease of integration into a customer’s system, and the laser itself can be controlled via computer communications interface and digital/analog interfaces. The beam is delivered through a detachable delivery (transport) fiber with a diameter of either 50 µm (BPP <2.5 mm mrad) or 100 µm (BPP <5 mm mrad), with industry standard QBH connectors on both ends.
• Disconnectable delivery fiber (QBH) with options of 50/100 μm with BPP <2.5/5 mm*mrad
The HighLight 1000FL fiber laser is designed and manufactured based on customers’ needs for high uptime in a manufacturing environment.
• Beam output optimized for cutting and welding applications
• High repetition rate pulse modulation capability (5 kHz) • Field serviceable modular design HighLight 1000FL Applications: • Cutting of Metals (Aluminum, Brass, Copper, Steel) • Welding of Metals • Fine Cladding
www.Coherent.com/HighLight1000FL
Superior Reliability & Performance
HighLight 1000FL
1 kW Industrial OEM Fiber Laser
System Specifications
HighLight 1000FL
Output Power (W)
>_1000
Power Stability (%)
<1
Maximum Repetition Rate (Hz)
5000
Minimum Pulse Width (μs)
50
Wavelength (nm)
1100 ±20
Polarization
Random
Beam Delivery
Replaceable QBH Fiber (Interlocked)
Delivery Fiber: Core Size (μm)
50 or 100
Delivery Fiber: Beam Parameter Product (mm*mrad)
<2.5 or <5
Mechanical Specifications Laser Module Dimensions (H x W x D)
566 x 380 x 1000 mm (22 x 15 x 39 in.)
Laser Module Weight
90 kg (200 lbs.)
Facilities Requirements Electrical Requirements (not including chiller) Operating Voltage (VAC) Frequency (Hz) Maximum Current Draw (A, each line) Cooling Requirements DI (deionized water) Flow Rate (l/min.) Pressure Drop (bar) Temperature (°C) Clean Filtered Water Flow Rate (l/min.) Temperature (°C) Purge Gas (oil-free) Flow Rate (std l/min.) Pressure (bar)
208 or 400/480 (3 phase) 50/60 15 or 10
8 <4 25 ± 1 8 25 ± 10 25 4
Environmental Conditions Operating Temperature
10 to 40°C (50 to 104°F)
Storage Temperature (drained and purged)
-20 to 70°C (-4 to 158°F)
Operating Humidity (%)
10 to 90, non-condensing
HighLight 1000FL
1 kW Industrial OEM Fiber Laser Mechanical Specifications
Top View 750 mm (29.5 in.)
127 mm (5.0 in.)
264 mm (10.4 in.)
Front View 380 mm (15.0 in.)
1000 mm (39.37 in.)
171 mm (6.76 in.)
25 mm (0.91 in.)
565 mm (22.25 in.) 467 mm (18.37 in.)
6 mm (0.23 in.)
Side View
Rear View
Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice. Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976.
www.Coherent.com Coherent, Inc.,
5100 Patrick Henry Drive Santa Clara, CA 95054 phone (800) 527-3786 (408) 764-4983 fax (408) 764-4646 e-mail
[email protected]
Printed in the U.S.A. MC-002-12-0M-0114Rev.C Copyright ©2014 Coherent, Inc.
Coherent offers a limited warranty for all HighLight 1000FL lasers. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative.
Benelux +31 (30) 280 6060 China +86 (10) 8215 3600 France +33 (0)1 8038 1000 Germany/Austria/ Switzerland +49 (6071) 968 333 Italy +39 (02) 31 03 951 Japan +81 (3) 5635 8700 Korea +82 (2) 460 7900 Taiwan +886 (3) 505 2900 UK/Ireland +44 (1353) 658 833
INVISIBLE AND/OR VISIBLE LASER RADIATION. AVOID EYE OR SKIN EXPOSURE TO DIRECT OR SCATTERED RADIATION. CLASS IV LASER PRODUCT PER EN60825-1 (2007) FIBER LASER 1100 nm ±20 nm 2 kW MAX. CW
DIODE LASER 635 nm 1 mW MAX. CW