Preview only show first 10 pages with watermark. For full document please download

Hipath 1220 - Tierone Telecommunications

   EMBED


Share

Transcript

HiPath 1220 Installation Manual Contents english 1 Important Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1.1 Basic Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1.2 Joining the Digital World of optiPoint 500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1.3 Additional Expansion Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2 Guidelines for Initial HiPath 1220 Start-Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3 Further Activities after Initial Start-Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.4 Reading Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5 Checking the Contents of the Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.6 Tools Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 1-1 1-1 1-1 1-2 1-2 1-3 1-4 1-5 1-7 1-8 2 Mounting the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 2.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 2.2 Selecting the Installation Site. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 2.3 Opening the System Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 2.4 Wall Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4 2.5 Connecting the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5 2.5.1 System Interfaces - Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5 2.5.2 Default Phone Number Allocation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6 2.5.3 Connecting Analogue Stations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 2.5.4 Connecting optiPoint 500 System Telephones . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8 2.5.5 Connecting ISDN Stations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9 2.5.6 S0 Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10 2.5.7 Connecting HiPath 1220 with the Computer . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11 2.5.8 Connecting the Power Supply Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13 3 System Expansion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1.1 Analogue Configuration Variants without UP0/E Base Module MSX . . . . . . . . . . . 3.1.2 Digital Configuration Variants with UP0/E Base Module MSX . . . . . . . . . . . . . . . . 3.1.3 Full Configuration with Analogue Stations and optiPoint 500 . . . . . . . . . . . . . . . . 3.2 Interfaces for Expanding the HiPath 1220 System . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2.1 Expanding the HiPath 1220 System for Digital Configuration . . . . . . . . . . . . . . . . 3.2.2 Expansion with optiPoint 500 System Telephones . . . . . . . . . . . . . . . . . . . . . . . . 3.2.3 Expansion with Analogue Telephones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2.4 Expansion with Relays, Sensors, Music on Hold . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 3-1 3-2 3-2 3-3 3-4 3-4 3-5 3-6 3-7 4 Installing the Computer Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1 Hardware and Software Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2 Computer Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3 Overview of Software Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3.1 Software Installation with ISDN0 Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 4-1 4-1 4-2 4-3 A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 0-1 English Nur für den internen Gebrauch HP1220_MaInstallTOC.fm Contents english HP1220_MaInstallTOC.fm Contents english Nur für den internen Gebrauch 4.3.2 Software Installation for Direct Computer <--> HiPath 1220 Connection over USB without Using On-Line Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4 4.3.3 Software Installation of HiPath 1220 Applications . . . . . . . . . . . . . . . . . . . . . . . . . 4-5 4.3.4 Software Installation for a Direct Computer <--> HiPath 1220 Connection over USB Using On-Line Services or Software Installation with USB Connection over optiPoint 500 . . . . . . . . . . . . . . . 4-6 4.3.4.1 Installing the USB/CAPI Driver under Windows 98 SE . . . . . . . . . . . . . . . . . . 4-8 4.3.4.2 Installing the USB/CAPI Driver under Windows ME . . . . . . . . . . . . . . . . . . . 4-10 4.3.4.3 Installing the USB/CAPI Driver under Windows 2000 . . . . . . . . . . . . . . . . . . 4-12 4.3.4.4 Installing the USB/CAPI Driver under Windows XP. . . . . . . . . . . . . . . . . . . . 4-14 4.3.4.5 Installing CAPI Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-16 4.3.4.6 On-Line Services and Fax Application Programs . . . . . . . . . . . . . . . . . . . . . 4-17 4.3.5 Uninstalling Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-17 4.4 Initial Start-Up (Starting HiPath 1220 Manager) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-18 4.5 Starting Other Computer Applications (For Default Installation) . . . . . . . . . . . . . . . . . 4-19 5 System CD Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1 6 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1 Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Y-1 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Z-1 0-2 A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 1 Important Information 1.1 General The HiPath 1220 system comes with a wide range of features and, thanks to its modular expansion properties, lends itself easily to customer-specific configuration. System configuration and administration could not be easier in HiPath 1220 -- all you need is a connected computer and the HiPath 1220 Manager and HiPath 1220 Accounting Manager software applications supplied. 7 1.1.1 The HiPath 1220 system may only be operated as an in-house communication system. In other words, the station cables must not exit the building. Failure to observe this installation requirement will result in operating licence withdrawal. Basic Configuration HiPath 1220’s basic configuration features two S0 interfaces for connection to two ISDN ports and four analogue interfaces for the connection of four analogue stations: ● USB port for connection to a Windows computer 1 ● User-friendly Windows tools, such as – Installation Wizard for rapid first-time installation (the first time you start HiPath 1220 Manager) – HiPath 1220 Manager for system installation and administration – Accounting Manager for transparent call data evaluation – LED Status Display for indicating the system operating states on the computer – MoH Transfer Wizard for transferring MIDI files in system format – Software Update Wizard for updating the system software over the computer 1. not available in all countries; administration then only possible via internal S0 connection. A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 1-1 English Nur für den internen Gebrauch 1_Wi_Hinw.fm Important Information General 1_Wi_Hinw.fm Important Information General 1.1.2 Nur für den internen Gebrauch Joining the Digital World of optiPoint 500 ● With a UP0/E base module (MSX) for joining the digital world of optiPoint 500 including two UP0/E interfaces for four optiPoint 500s, two of which are connected via optiPoint phone adapters with local power supply (requirement for operation with MPXU modules), ● With UP0/E modules (MPXU) for two-phase expansion to a maximum of eight optiPoint 500 system telephones. For each optiPoint 500, one additional optiPoint 500 can be connected via an optiPoint phone adapter with local power supply attached. 1.1.3 Additional Expansion Options ● With analogue modules (MPXA) for two-stage expansion to a maximum of twelve analogue stations. ● With a random mix of optiPoint 500 and analogue stations, the maximum configuration possible consists of sixteen optiPoint 500s (connected via optiPoint phone adapter with local power supply) and six analogue stations. ● With the relay/sensor module (MFXAS) for alarm generation and management options and an external music-on-hold facility (without port loss). 1-2 A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 1_Wi_Hinw.fm Nur für den internen Gebrauch 1.2 Important Information Guidelines for Initial HiPath 1220 Start-Up Guidelines for Initial HiPath 1220 Start-Up The following steps should be performed for starting up the HiPath 1220 system: Prepare for start-up by – Reading Safety Information. – Checking the Contents of the Package. – Tools Required. 2. Mounting the System. 3. Connecting the System (see also housing label). 4. Installing Computer Software. 5. Calling up HiPath 1220 Manager. (Default Password 31994). Enter basic settings with the installation wizard, for example – enter multiple subscriber numbers (MSN), – assign multiple subscriber numbers (MSN) to the stations connected, – make entries for the central phone book, – assign names to the extensions connected – enter settings for the call charge accounts. English 1. 6. Changing the Default Configuration of the HiPath 1220 System in HiPath 1220 Manager as Required. 7. Saving all Settings Made in the HiPath 1220 Communication System (Saving Configuration Data). Your HiPath 1220 communication system is now ready for operation. You should now test the basic functions of your HiPath 1220 communication system. > You will find a list of the documentation available on your HiPath 1220 system in Chapter 5, "System CD Documentation". A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 1-3 1_Wi_Hinw.fm Important Information Further Activities after Initial Start-Up 1.3 Nur für den internen Gebrauch Further Activities after Initial Start-Up ● Make further changes to the configuration with HiPath 1220 Manager. ● Tell the user about the existing telephone settings in the default configuration or the settings that you changed, such as number of extensions, group call number, pickup group, and function key assignment in system telephones (optiPoint 500 stations if available). ● Fill out and print out label sheet for the system telephone/s (optiPoint 500 stations, if available). ● Back up data. 1-4 A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 1_Wi_Hinw.fm Nur für den internen Gebrauch 1.4 Important Information Reading Safety Information Reading Safety Information Safety symbols 7 Warning This symbol calls attention to a danger that may cause serious injury. 7 Caution This symbol calls attention to a danger that may damage or destroy hardware or software. Further symbols for determining the source of danger in greater detail These symbols are not usually used in the manual. They are an explanation of the symbols that may be depicted on the systems. 1 Electricity 4 ESD* * Electrostatic discharge Information symbol > This symbol indicates useful information. A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 1-5 English Potential sources of danger are indicated in this manual by the following symbols: 1_Wi_Hinw.fm Important Information Reading Safety Information Nur für den internen Gebrauch Safety information Do not operate the hardware component of your HiPath 1220 in environments where there is risk of explosion. Avoid contact between the hardware components of your HiPath 1220 and coloured or aggressive liquids, such as tea, coffee, juices or soft drinks. The information provided in this document contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. Symbols The device conforms to the EU directive 1999/5/EG, as attested by the CE mark. This device has been manufactured in accordance with our certified environmental management system (ISO 14001). This process ensures that energy consumption and the use of primary raw materials are kept to a minimum, thus reducing waste production. 1-6 A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 1_Wi_Hinw.fm Important Information Checking the Contents of the Package Nur für den internen Gebrauch 1.5 Checking the Contents of the Package Procedure Activity 1. Check the components delivered against the following list to ensure that nothing is missing. 2. Determine whether any damage has occurred during transport and report it to the appropriate dealer or shipper. 3. Packing material should be disposed of in accordance with the applicable specifications in your country. 7 Use only equipment and materials that are in perfect working order. Do not start up equipment with visible damage. Contents of the package Contents of the HiPath 1220 package ● HiPath 1220 communication system ● Local power supply unit ● 1 x 3-m S0 cable for connection to the ISDN port ● 1 x 3-m S0 cable for connection to the PC’s ISDN port 1 ● 1 x 2-m USB cable for connection to the computer 2 ● 1 x 4-pin screw terminal for connecting the system telephones (only in combination with the digital UP0/E base module MSX) ● 1 x 8-pin screw terminal for connecting the analogue stations ● Mounting equipment ● 1 2 – 1 x drill template – 2 x S6 wall anchors – 2 x mounting screws ∅ 4 mm Accessory pack including – installation manual with – internal system CD For country versions (not Germany) Only for country versions with USB port A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 1-7 English Step 1_Wi_Hinw.fm Important Information Tools Required 1.6 Nur für den internen Gebrauch Tools Required You will need the following tools for mounting the HiPath 1220 system: ● Diagonal cutting pliers, telephone pliers, wire stripper ● Flat-blade screwdriver (2.5 to 5.5 mm) ● Drill, hammer (for wall mounting) ● Spirit level, ruler (for wall mounting) 1-8 A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual Nur für den internen Gebrauch 2 Mounting the System 2.1 General 2_Montage.fm Mounting the System General The HiPath 1220 system housing is designed for wall mounting. Desktop installation is possible but not recommended for safety reasons (loose cables, removable connectors). 1. Opening the System Housing 2. Selecting the Installation Site 3. Connecting the System – Connecting Analogue Stations – Connecting optiPoint 500 System Telephones – Connecting ISDN Stations – S0 Connection – Connecting HiPath 1220 with the Computer – Connecting the Power Supply Unit 4. Performing Visual Inspection, 5. Closing the System Housing > English Follow the steps described below to mount the system: To enable the computer to detect the HiPath 1220 system automatically, do not connect the system and the computer until you have started up HiPath 1220 and booted the computer. To close the system housing, start by connecting the USB or S0 cable (depending on the type of connection) on the system side. A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 2-1 2_Montage.fm Mounting the System Selecting the Installation Site 2.2 Nur für den internen Gebrauch Selecting the Installation Site You must take the following into account when selecting the site: ● The connection cables supplied permit the following distances: – Distance between system and computer: approximately 1.5 m. – Distance between system and ISDN port (NTBA): approximately 2.5 m. – Distance between system and power outlet: approximately 1.5 m ● To guarantee sufficient system ventilation, leave at least 10 cm clearance around the housing. ● Do not sit or install on a metallic base. ● Do not expose the systems to direct sources of heat (such as sunlight and heaters). ● Do not expose the systems to extremely dusty environments. ● Avoid contact with chemicals. ● Take every precaution to prevent the formation of condensation on the system during operation. If condensation forms on a system, make sure the system has time to dry completely before starting it up. ● To guarantee safety in the location selected for desktop installation, ensure that the lines exiting the system after cable connection are secured externally and are not at risk of disconnection by third parties. You can start to connect cables once the HiPath 1220 system has been safely and securely installed (see Section 2.5, "Connecting the System"). 2-2 A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 2_Montage.fm Mounting the System Opening the System Housing Nur für den internen Gebrauch 2.3 Opening the System Housing English Open the cover on the system housing (for mounting and connecting cables) 1a 1. 1b Grasp the lower edge on the front of the 2. lower system housing cover in the centre and ease outwards Open the mid-section of the system housing (for expansion with MPXA, MPXU, and MFXAS plug-in modules) and at the same time lift up the system housing cover. Open the base module lid (for expansion with the UP0/E base module MSX for digital configuration) c d e 2 3 Unlatch the mid-section of the system housing Press the mid-section of the base module covby inserting a 2.5-mm screwdriver into the er lightly and lift off the cover. latch hole on the left (1) and applying a light pressure. Then slide back the cover (2) and (3) lift it off A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 2-3 2_Montage.fm Mounting the System Wall Mounting 2.4 Nur für den internen Gebrauch Wall Mounting Step 1 1 Step 2 2 Step 3 Step 4 3 4 7 Do not connect the local power supply unit to the power outlet until all cables have been connected to your HiPath 1220 communication system. 2-4 A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 2_Montage.fm Mounting the System Connecting the System Nur für den internen Gebrauch 2.5 Connecting the System ● HiPath 1220 without digital UP0/E base module MSX, features two S0 interfaces and four analogue interfaces for connecting analogue stations. ● HiPath 1220 with digital UP0/E base module MSX, features two S0 interfaces, four analogue interfaces and two UP0/E interfaces for connecting four analogue stations and two optiPoint 500 system telephones over the two additional optiPoint 500s with local power supply unit attached connected via an optiPoint phone adapter. 2.5.1 System Interfaces - Overview HiPath 1220 with UP0/E base module HiPath 1220 without UP0/E base module A a b c d e A f g b c d e f g a) Two UP0/E interfaces for connecting two optiPoint 500s or four with phone adapter and local power supply unit (optional) b) Power supply unit for power feed c) First S0 bus port for connecting the ISDN connection’s NTBA d) Second S0 bus port for connecting a second NTBA or e) A parallel, crossed, second S0 bus port for the internal connection of ISDN stations (for example, PC with ISDN card) f) USB port for connecting the computer1 g) Four analogue interfaces for connecting four analogue stations A) Four slots for system expansion 1 Only for country versions with USB port A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 2-5 English The HiPath 1220 communication system comes in two different basic configurations. 2_Montage.fm Mounting the System Connecting the System 2.5.2 Nur für den internen Gebrauch Default Phone Number Allocation The following table shows number allocation in the default configuration of the HiPath 1220 system. > This information corresponds to your HiPath 1220 system’s default settings. To assign multiple subscriber numbers (MSN) to stations, see Section 4.4, "Initial StartUp (Starting HiPath 1220 Manager)". Purpose Inputs Internal default station numbers (direct to the system) 11 – 24 Internal default station numbers (over optiPoint adapter) 41,42, 47 – 52 Internal S0 bus default station number (S0 2 internal) 71 USB-CAPI internal default station number3 103 For complete information about the default hardware configuration, please refer to Section 8.2, "Numbering Plan" in the HiPath 1220 Manager documentation. Overview of default phone number allocation (internal station numbers) System expansion1 1 2 3 11 12 41 42 EM 12 HiPath 1220 base module a/b 13 14 S0 15 16 EM 22 EM 32 EM 42 USB3 71 10 17 18 19 20 21 22 47 48 49 50 51 52 23 24 UP0/E base module (MSX) Expansion modules EM 1 to 3 (MPXA/MPXU), expansion module EM 4 (MPXA/MFXAS) Only for country versions with USB port As phone numbers can be freely allocated in HiPath 1220 Manager, you can use the following table to enter them when assigning new numbers or changing existing ones. UP0/E base module (MSX)/base module (MSC) System expansion HiPath 1220 base module S0 2 int. a/b USB3 Expansion modules EM 1 to 4 (MPXA/MPXU/MFXAS) EM 11 1 EM 21 EM 31 EM 41 Expansion modules EM 1 to 3 (MPXA/MPXU), expansion module EM 4 (MPXA/MFXAS) 2-6 A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 2_Montage.fm Mounting the System Connecting the System Nur für den internen Gebrauch 2.5.3 Connecting Analogue Stations You can connect up to four analogue stations in the basic configuration. Two cabling variants are available for analogue stations in the basic configuration: Variant 2 Cable connection using telephone cables without cable connectors for remote stations. ● Open the lower system housing cover (see Section 2.3, "Opening the System Housing"). ● Open the lower system housing cover (see Section 2.3, "Opening the System Housing"). ● Plug the TAE/RJ11 connector provided on the analogue station’s connection cable into one of the TAE/RJ11 jacks (13 to 16. In the default configuration, the TAE/ RJ11 jack number matches the internal station number. ● Assign the 8-pin screw terminal on the basis of the station you want to connect. 8-pin screw terminal a1 b1 a2 b2 a3 b3 a4 b4 or 13 / 14 / 15 / 16 13 / 14 / 15 / 16 TAE connector assignE (d) 4 3 w(c) 5 RJ11 - connector as- Plug the 8-pin screw terminal into the "...analogue phone" jack. 2b F 6 1a 1234 7 Dual or triple assignment is not permitted for ports 13 to 16 using the TAE and/or RJ11 jack and screw terminal!!! A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 2-7 English Variant 1 Cable connection using pre-terminated connection cables with TAE or RJ11 connectors for stations installed near the system. 2_Montage.fm Mounting the System Connecting the System 2.5.4 Nur für den internen Gebrauch Connecting optiPoint 500 System Telephones The HiPath 1220 system features a digital UP0/E base module MSX and permits the connection of two optiPoint 500 system telephones in the basic configuration. Two cabling variants are available for system telephones in the basic configuration: Variant 1 Cable connection using pre-terminated connection cables with RJ11 connectors for system telephones installed near the system. Variant 2 Cable connection using telephone cables without cable connectors for remote system telephones. ● Open the lower system housing cover (see Section 2.3, "Opening the System Housing"). ● Open the lower system housing cover (see Section 2.3, "Opening the System Housing"). ● Plug the RJ11 connector provided on the system telephone’s connection cable into one of the jacks (11 or 12). In the default configuration, the jack number matches the internal station number. ● Assign the 4-pin screw terminal on the basis of the system telephones you want to connect. 4-pin screw terminal a1 b1 a2 b2 11 / 12 41 41 7 11 12 11 / 12 42 42 Dual assignment is not permitted for ports 11 and 12 with the RJ11 jack and screw terminal. When using an optiPoint adapter in an optiPoint 500 (advanced/standard or basic), you can connect a second station depending on the type of adapter used. The second stations connected in this way are assigned the phone numbers 41 and 42 in the default configuration and can set up or accept calls irrespective of the optiPoint 500 connection status, provided a B-channel is available. You can connect a second station to an optiPoint 500 (advanced/standard or basic) in the HiPath 1220 system using the following adapters: 2-8 A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 2_Montage.fm Mounting the System Connecting the System Nur für den internen Gebrauch optiPoint ISDN adapter to connect an ISDN station or a PC card optiPoint phone adapter to connect a second optiPoint 500 station (client) 7 When using the adapter described above, you must install a local power supply unit between the optiPoint 500 and the station you want to connect. 7 If you use the USB port on an optiPoint 500 to connect a computer (for administration, Internet, or other applications), the computer is treated like a second station. You may not operate any of the optiPoint adapters described above at this optiPoint 500. You can use the following adapters to operate additional accessories at an optiPoint 500 (advanced/standard or basic). optiPoint acoustic adapter to connect a headset, ext. microphone and loudspeaker, two switching contacts optiPoint recorder adapter to connect a recording device, second handset For more information on optiPoint adapter assembly and installation, see "Installation Manual for optiPoint Key Modules, Adapters and Accessories" on the system CD (see also Chapter 5, "System CD Documentation"). 2.5.5 Connecting ISDN Stations Two variants are available for connecting an ISDN station to the HiPath 1220 system: 1. Direct connection to the S02 internal port on the system see the next Section 2.5.6, "S0 Connection" figure C or Internal S0 bus default station number (S0 2 internal) 2. 71 Connection over an optiPoint 500 ISDN adapter connected to an optiPoint 500, see "Installation Manual for optiPoint Key Modules, Adapters and Accessories" on the system CD (see also Chapter 5, "System CD Documentation"). Internal default station numbers (over optiPoint adapter) A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 41,42, 47 – 52 2-9 English optiPoint analogue adapt- to connect an analogue station, modem er 2_Montage.fm Mounting the System Connecting the System 2.5.6 Nur für den internen Gebrauch S0 Connection Your HiPath 1220 system comes with an S0 cable (3 m) for connecting the system to an available ISDN port (see figure A). > The distance between system and ISDN port should not exceed 2.5 m. Operating the HiPath 1220 systemat one ISDN port Operating the HiPath 1220 systemat two ISDN ports NTBA NTBA NTBA S0 1 S0 2 S0 2 Ext S0 1 S0 2 S0 2 Ext A Ext Ext Int Int B Connecting ISDN stations to the HiPath 1220 system The length of the ISDN station’s connection cord must not exceed 10 m. NTBA You can only operate ISDN stations with internal power supply. This means there is no feeding voltage on S0 2 internal. C S0 1 S0 2 S0 2 Ext Ext Int The internal default station number for S0 2 internal is 71. 7 S0 2 External and S0 2 Internal must not be seized simultaneously! 7 Using only one S0 Port (External/internal S0 2 trunk is not used and not connected) the second S0 Port must be configured as S0 Bus (internal connection) (see HiPath 1220 Manager Documentation Section 4.4, “ISDN Operation Mode”). 2-10 A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 2_Montage.fm Mounting the System Connecting the System Nur für den internen Gebrauch 2.5.7 Connecting HiPath 1220 with the Computer If the computer is connected to the system with the USB cable supplied (only for country versions with USB port), you must install the USB drivers supplied before installing the HiPath 1220 applications. As the installation of these drivers automatically starts with the connection of the USB cable, you should wait until shortly before software installation to do this (see Section 4.3, "Overview of Software Installation"). A communication server (CommServer) is used for communication between the computerbased HiPath 1220 applications and the system. This CommServer is automatically installed and inserted in the Startup group when a HiPath 1220 application is installed. The CommServer is consequently automatically started every time the computer is switched on and is available for the computer <--> system connection. ISDN S0 connection variants USB connection variants ISDN S0 configuration options HiPath 1220 applications Manager SW Update MoH Transfer Accounting LED Status HiPath 1220 applications Manager SW Update MoH Transfer Accounting LED Status CAPI driver ISDN card CommServer to the optiPoint with ISDN adapt- USB configuration options S0 ISDN 2 CommServer CallBridge for Data 4 3 USB 1 HiPath 1220 UP0/E S02 int. S01 ext. NTBA ISDN A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual HiPath 1220 UP0/E USB S01 ext. NTBA ISDN 2-11 English HiPath 1220 lets you operate your computer over an ISDN S0 connection or over the USB port. 2_Montage.fm Mounting the System Connecting the System Nur für den internen Gebrauch ISDN S0 connection variants 1. Direct connection from your computer’s S0 port (ISDN card) to the system’s S02 internal port 2. Connection from your computer’s S0 port (ISDN card) to the S0 port on the ISDN adapter in optiPoint 500 and over UP0/E to the system. In both connection variants, CommServer Configuration must be performed as follows after installing the HiPath 1220 applications: (Right-click the CommServer icon in the Windows status bar and select Properties) Enter the following settings: Connection Type: ISDN Connection Tel. no.: 800 Own MSN: --USB connection variants 3.a Direct connection from your computer’s USB port to the system’s USB portwithout using on-line services (default variant). 3.b Direct connection from your computer’s USB port to the system’s USB portusing on-line services. 4. Connection from your computer’s USB port to the USB port on the optiPoint 500 and over UP0/E to the system. Depending on the connection variant, you should ● enter data during USB driver installation or ● configure the CommServer after installing the software Variant 3a (default variant) does not require you to enter data while installing the USB drivers or configure the CommServer after installing them. Variant 3b and variant 4 7 If you have already installed a third-party CAPI driver or an ISDN card on your computer, you must uninstall these completely before you install the CallBridge for Data software separately supplied on the system CD. You must install a separate USB driver (CallBridge for Data) for variant 3b and variant 4 (see Software Installation for a Direct Computer <--> HiPath 1220 Connection over USB Using On-Line Services or Software Installation with USB Connection over optiPoint 500). 2-12 A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 2_Montage.fm ● When prompted to enter the MSN number (Multiple Subscriber Number) during USB driver installation, enter the following: for variant 3b: MSN = 10 for variant 4: MSN = (41 or 42 or 47 to 52) The phone number you should enter as the MSN depends on the port to which the optiPoint 500 system telephone is connected (see Section 2.5.2, "Default Phone Number Allocation") and that was connected to the computer. See also Section 4.3.4.1 to Section 4.3.4.4 Installing the USB Drivers under Windows ... ● Perform CommServer Configuration as follows after installing the software: (Right-click the CommServer icon in the Windows status bar and select Properties) Enter the following settings: Connection Type: ISDN Connection Tel. no.: 800 Own MSN: --● The CommServer must be closed down to apply these settings. Every time you call up a HiPath 1220 application, a new session is automatically started. 7 2.5.8 Only one of these four variants may be used/installed per computer. Connecting the Power Supply Unit The local power supply unit provided comes with a connection cable approximately 1.5 m in length. Plug the local power supply’s connector into the power supply unit PSU. You can connect the local power supply unit to the PSU if your HiPath 1220 system is connected to all components required. 7 The system must be de-energised before expansion modules can be connected. A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 2-13 English Mounting the System Connecting the System Nur für den internen Gebrauch 2_Montage.fm Mounting the System Connecting the System 2-14 Nur für den internen Gebrauch A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual Nur für den internen Gebrauch 3 System Expansion 3.1 General 3_Erweiterung.fm System Expansion General The HiPath 1220 system is also available with the digital UP0/E base module MSX for entry into the world of optiPoint 500. The HiPath 1220 system’s flexible structure supports customer-specific expansion with ● up to 12 analogue terminals ● up to 16 optiPoint 500s (using optiPoint phone adapters and local power supply units) and six analogue stations ● random optiPoint 500/analogue station combinations ● connection module for alarm generation and management and an external music-on-hold facility. The HiPath 1220 system can be equipped with up to four expansion modules. The following expansion modules are available for configuring or expanding your HiPath 1220 system. Module Part number Remark MSX S30807-Q6940-X-* Used for expanding the HiPath 1220 system for digital configuration including two UP0/E interfaces to connect two optiPoint 500s or four optiPoint 500s with the optiPoint phone adapter. (HiPath 1220 is also available with an in-built MSX.) MPXU S30807-Q6941-X-* Used for expansion with two UP0/E interfaces to connect two optiPoint 500s or four optiPoint 500s with the optiPoint phone adapter (requirement: the HiPath 1220 system is fitted with the UP0/E base module MSX). MPXA S30807-Q6942-X-* Used for expanding the basic configuration with two analogue interfaces for connecting two analogue stations. MFXAS S30807-Q6944-X-* Used for expanding the basic configuration with two sensors, two relays for alarm generation and management and an interface for an external music-on-hold facility. 7 Systems must be de-energised before you start expansion work. A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 3-1 English The HiPath 1220 system features two S0 and four analogue interfaces in the basic configuration. 3_Erweiterung.fm System Expansion General 3.1.1 Nur für den internen Gebrauch Analogue Configuration Variants without UP0/E Base Module MSX Basic configuration Variants with expansion modules in Total configuration slots PX1 to PX4 PX1 PX2 PX3 PX4 2 x S0 / 6 x a/b MPXA MPXA MSC with 2 x S0 4 x a/b 1 MFXAS 2 x S0/6 x analogue + MFXAS feature1 2 x S0 / 8 x a/b MPXA MPXA MPXA MPXA MPXA MPXA MPXA MPXA MPXA MPXA MFXAS MPXA MPXA MPXA MPXA MFXAS 2 x S0/8 x analogue + MFXAS feature1 2 x S0 / 10 x a/b 2 x S0/10 x analogue + MFXAS feature1 2 x S0 / 12 x a/b The MFXAS features two sensors or two relays for alarm generation and management and an interface for an external music-on-hold facility. 3.1.2 Digital Configuration Variants with UP0/E Base Module MSX Basic configuration Variants with expansion modules in Total configuration slots PX1 to PX4 PX1 MSC with 2 x S0 4 x analogue and MSX with 2 x UP0/E 1 2 PX2 PX3 PX4 2 x S0 / 4 x a/b / 4 x UP0/E1 MPXU MPXU MFXAS 2 x S0/4 x analogue/4 x UP0/E 1 +MFXAS2 2 x S0 / 4 x a/b / 6 x UP0/E1 MPXU MPXU MPXU MPXU MPXU MPXU MPXU MPXU MPXU MPXU MFXAS 2 x S0/4 x analogue/6 x UP0/E1 + MFXAS2 2 x S0 / 4 x a/b / 8 x UP0/E1 MFXAS 2 x S0/4 x analogue/8 x UP0/E 1 + MFXAS2 If your optiPoint 500 has an optiPoint phone adapter, you can connect a second optiPoint 500 with local power supply unit and operate two optiPoint 500s for every UP0/E interface. The MFXAS module features two sensors or two relays for alarm generation and management and an interface for an external music-on-hold facility. 3-2 A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 3_Erweiterung.fm System Expansion General Nur für den internen Gebrauch Full Configuration with Analogue Stations and optiPoint 500 Basic configuration MSC with 2 x S0 4 x analogue and MSX with 2 x UP0/E Variants with expansion modules in slots PX1 to PX4 PX1 PX2 PX3 PX4 MPXU MPXA MPXA MPXA MPXU MPXA MPXA MFXAS Total configuration 2 x S0 / 10 x a/b / 4 x UP0/E 2 x S0/8 x analogue/4 x UP0/E English 3.1.3 +MFXAS1 MPXU MPXU MPXA MPXA MPXU MPXU MPXA MFXAS 2 x S0 / 8 x a/b / 6 x UP0/E 2 x S0/6 x analogue/6 x UP0/E 1 + MFXAS MPXU MPXU MPXU MPXA MPXU MPXU MPXU MFXAS 2 x S0 / 6 x a/b / 8 x UP0/E 2 x S0/4 x analogue/8 x UP0/E + MFXAS1 When your optiPoint 500 has an optiPoint phone adapter, you can connect a second optiPoint 500 with local power supply to create a full configuration that offers all of the following system features: ● 2 x ISDN ports ● 4 x analogue stations ● 16 optiPoint 500s ● 2 x sensors ● 2 x relays ● 1 x external music-on-hold facility 1 The MFXAS module features two sensors or two relays for alarm generation and management and an inter- face for an external music-on-hold facility. A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 3-3 3_Erweiterung.fm System Expansion Interfaces for Expanding the HiPath 1220 System 3.2 Nur für den internen Gebrauch Interfaces for Expanding the HiPath 1220 System The MSC base module features the following interfaces: ● Interfaces SX1 to SX2; to connect the digital UP0/E base module MSX and ● Interfaces PX1 to PX4; to expand the systems with the expansion modules MPXA, MPXU, and MFXAS. SX1 7 SX2 The slot to the left of PX1 is provided for subsequent expansion and must be left free. * not intended for use in Germany 3.2.1 Expanding the HiPath 1220 System for Digital Configuration You must connect the digital UP0/E base module MSX to the MSC base module to expand the HiPath 1220 system with digital optiPoint 500 system telephones. 7 Systems must be de-energised before you start expansion work. To do this, proceed as follows: 1. Open the system housing as described in Section 2.3, steps 1 to 3. 2. Remove the MSC base module from the lower part of the housing. 3. Plug the module connector into the SX1 and SX2 interfaces on the MSC and connect it to the UP0/E base module MSX. 4. Place the connected MSC and MSX in the plastic brackets provided in the lower part of the housing. 5. Close the base module cover and the mid-section of the system housing. 6. For information on connecting optiPoint 500 system telephones, see Section 2.5.4 3-4 A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 3_Erweiterung.fm System Expansion Interfaces for Expanding the HiPath 1220 System Nur für den internen Gebrauch Expansion with optiPoint 500 System Telephones If the MSC base module is fitted with a UP0/E base module MSX, you can expand your HiPath 1220 system to include two UP0/E interfaces per MPXU expansion module in order to connect two optiPoint 500 system telephones. HiPath 1220 can be expanded with up to three expansion modules MPXU, which means that, including the MSX, you can connect eight system telephones (1 x MSX + 3 x MPXU) directly to the system. You can connect another optiPoint 500 to each of these eight system telephones by installing an optiPoint phone adapter, with the result that four optiPoint 500s can be operated per MPXU/MSX. In this way you can achieve a maximum configuration with up to sixteen optiPoint 500 system telephones. Proceed as follows to install the MPXU expansion module: 1. Open the system housing as described in Section 2.3, steps 1 to 2. 2. Plug the MPXU expansion module into one of the four slots (PX1 to PX3). 3. Punch out the recess in the mid-section of the system housing. 4. Close the mid-section of the system housing. 5. Assign the 4-pin screw terminal on the basis of system telephones you want to connect and connect to the PCB board port (see following diagram). 4-pin screw terminal a1 b1 a2 b2 The optiPoint phone adapter lets you connect a second optiPoint 500 system telephone with local power supply to the first optiPoint 500. *) *) For more information on connecting optiPoint adapters, see the "Installation Manual for optiPoint Key Modules, Adapters and Accessories" on the system CD (Chapter 5, "System CD Documentation"). 7 If you are using an optiPoint 500 USB port (for administration, Internet or similar applications), then you cannot use an optiPoint adapter at this port. The following internal phone numbers (default configuration) are assigned to the extensions on the basis of the expansion slot where the MPXU is connected: A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 3-5 English 3.2.2 3_Erweiterung.fm System Expansion Interfaces for Expanding the HiPath 1220 System PX1 a/b wire assignment Nur für den internen Gebrauch PX2 PX3 PX4 a1/b1 a2/b2 a1/b1 a2/b2 a1/b1 a2/b2 internal phone number 17 18 19 20 21 22 over optiPoint phone adapter 47 48 49 50 51 52 3.2.3 Must not be seized with an MPXU. Expansion with Analogue Telephones Your HiPath 1220 system can be expanded to include two analogue interfaces for each MPXA expansion module. Proceed as follows to install the MPXA expansion module: 1. Open the system housing as described in Section 2.3, "Opening the System Housing", steps 1 to 2. 2. Plug the MPXA expansion module into one of the four slots (PX1 to PX4). 3. Punch out the recess in the mid-section of the system housing. 4. Close the mid-section of the system housing. 5. Assign the 4-pin screw terminal on the basis of telephones you want to connect and connect to the PCB board port (see following diagram). 4-pin screw terminal a1 b1 a2 b2 The following internal phone numbers (default configuration) are assigned on the basis of the expansion slot where the MPXU is connected: PX1 a/b wire assignment internal phone number 3-6 PX2 PX3 PX4 a1/b1 a2/b2 a1/b1 a2/b2 a1/b1 a2/b2 a1/b1 a2/b2 17 18 19 20 21 22 23 24 A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 3_Erweiterung.fm Nur für den internen Gebrauch 3.2.4 System Expansion Interfaces for Expanding the HiPath 1220 System Expansion with Relays, Sensors, Music on Hold ● two sensors for recognising operating modes (for example, alarms) ● two relays for controlling operating modes (for example, door openers) and ● an interface for an external music-on-hold facility to use the MusicOnHold feature via an external music source (for example, CD player). Proceed as follows to install the MFXAS expansion module: 1. Open the system housing as described in Section 2.3, steps 1 to 2. 2. Plug the MFXAS expansion module into slot PX4. 3. Punch out the right recess in the mid-section of the system housing. 4. Close the mid-section of the system housing. 5. Assign the 10-pin screw terminal on the basis of components you want to connect and connect to the PCB board port (see following diagram). Sensors Relays 7 The MFXAS expansion module may only be connected at expansion slot PX4. MusicOnHold Both of the sensor interfaces recognises the switching states (open/closed) of the connected contacts. The following electrical values must be observed for cable connection: ● maximum line resistance: 2 x 50 ohms, ● maximum line length: 150 m (in-house cables only) ● maximum loss of voltage over closed sensor contact: 2 V 7 You may only connect floating make or break contacts at the sensor inputs. Do not connect noise voltage. A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 3-7 English When you install the MFXAS expansion module, your HiPath 1220 system has 3_Erweiterung.fm System Expansion Interfaces for Expanding the HiPath 1220 System Nur für den internen Gebrauch Both of the relay interfaces features a 3-pin contact that can operate as a make or break contract. The following electrical values must be observed: ● maximum operating voltage: 60 Vdc or 30 Vac ● maximum current: 1 A 7 You must not connect any line voltage feeders to the relays or sensors. Suitable AC power circuit interrupters should always be installed between the line voltage and the relays or sensors (by service personnel only). The interface for external music on hold lets you connect a permanent external music source over the relay with optional start and stop function. 7 Copyright regulations as stipulated by GEMA (German Copyright Society) must be observed when playing melodies from external audio devices for music on hold. Connect the external music source to the MFXAS expansion module over a 3.5-mm stereo jack connector (lower switchboard jack). 3-8 A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 4_PC_Install.fm Installing the Computer Software Hardware and Software Requirements Nur für den internen Gebrauch 4 Installing the Computer Software 4.1 Hardware and Software Requirements Software ● Pentium II processor, 200 MHz/64 MB RAM ● Windows 98 SE®/Windows ME® ● 150 MB free memory on the hard disk ● Windows 2000® and Windows XP® SP 1 ● A free USB port1 or an ISDN port1 ● CD-ROM drive 1 (administrator privileges required) USB port not available in all countries. Note: You can find more information on the system in the "Readme.txt" file on the system CD. 4.2 Computer Software The following software is available on the system CD supplied: ● ● HiPath 1220 applications that can be installed in the Setup window – HiPath 1220 Manager: configuration/administration software. – Accounting Manager: call charge evaluation software. – LED Status Display: LED status display on the computer. – MoH Transfer Wizard: MIDI transfer wizard for converting MIDI files into the HiPath 1220 format and transferring them to the system. – Software Update Wizard: wizard for updating the system software. – TAPI driver: driver software for connecting a computer with CTI software at the optiPoint 500 USB port. Additional software – CommServer: communication server as data interface between the HiPath 1220 system and the HiPath 1220 computer applications (automatically installed with one of the software packages described above). – CAPI applications: CallBridge for Data Utilities (software for ISDN applications, such as Internet access, Group 3 or 4 fax transmission/receipt, Euro File Transfer, telephone emulation, etc.). A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 4-1 English Hardware 4_PC_Install.fm Installing the Computer Software Overview of Software Installation 4.3 Nur für den internen Gebrauch Overview of Software Installation The software installation procedure should be selected on the basis of the computer <--> HiPath 1220 connection variant. Software Installation with ISDN0 Connection ● For a computer <--> HiPath 1220 or computer <--> optiPoint 500 (with ISDN adapter) <--> HiPath 1220 ISDN0 connection, you only have to install the HiPath 1220 applications and enter the appropriate settings in CommServer after restarting your computer (see Section 4.3.1, "Software Installation with ISDN0 Connection"). Software Installation for Direct Computer <--> HiPath 1220 Connection over USB without Using On-Line Services ● For a direct computer <--> HiPath 1220 connection over USB, you must install the USB drivers provided on the system CD before you install the HiPath 1220 applications. No other settings are required after installing the HiPath 1220 applications and restarting the PC (see Section 4.3.2, "Software Installation for Direct Computer <--> HiPath 1220 Connection over USB without Using On-Line Services"). Software Installation for a Direct Computer <--> HiPath 1220 Connection over USB Using On-Line Services or Software Installation with USB Connection over optiPoint 500 ● 7 If you have already installed a third-party CAPI driver or an ISDN card on your computer, you must uninstall these completely before you install the CallBridge for Data software. For a direct computer <--> HiPath 1220 connection over USB using on-line services or a USB connection over optiPoint 500, you must prepare the USB drivers for the separately supplied "CallBridge for Data" software and install them with the CAPI applications before you install the HiPath 1220 applications. Then you can install the HiPath 1220 applications. You must also enter the appropriate connection-variant-specific settings in the CommServer after you restart the computer (see Section 4.3.4, "Software Installation for a Direct Computer <--> HiPath 1220 Connection over USB Using On-Line Services or Software Installation with USB Connection over optiPoint 500"). > 4-2 You should check if all stations are connected and all necessary connections were set up before you initiate the setup program (see Section 2.5, "Connecting the System"). A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 4_PC_Install.fm Nur für den internen Gebrauch Software Installation with ISDN0 Connection 1. Insert the system CD in your CD drive. If you have not configured a Startup function, select Start | Run in the Windows start menu and click Browse to open the file :\SETUP.EXE on the CD. 2. Select the required language (German or English) in the Setup window. 3. Click Installation in the Setup window. The selection window appears with the software you want to install. 4. Install the required software components one after the other (see Section 4.2, "Computer Software") by clicking the appropriate button. The following programs (at least) are required for operating the HiPath 1220 system. ● HiPath 1220 Manager ● CommServer (automatically installed) To install additional software components, click the appropriate button again and follow the instructions. 5. After installing the individual components, you receive a message that installation was successful. Confirm this message with Finish. Once the required software packages have been installed, you can close the Setup window with Exit. The software is now installed. Please restart the computer. after restarting your computer. To do this, right-click the CommServer icon in the Windows status bar and select Properties. Enter the following settings: ● Connection Type: ISDN Connection ● Tel. no.: 800 Own MSN: --● The CommServer must be closed down to apply these settings. Every time you call up a HiPath 1220 application, a new session is automatically started. 7 Only one of the four installation variants may be installed per computer (see Section 2.5.7, "Connecting HiPath 1220 with the Computer") Your computer is ready for operation see Section 4.4, "Initial Start-Up (Starting HiPath 1220 Manager)". A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 4-3 English 4.3.1 Installing the Computer Software Overview of Software Installation 4_PC_Install.fm Installing the Computer Software Overview of Software Installation 4.3.2 Nur für den internen Gebrauch Software Installation for Direct Computer <--> HiPath 1220 Connection over USB without Using On-Line Services If your computer is connected to the system with the USB cable supplied (only for country versions with USB port) for the exclusive purpose of administering the HiPath 1220 system, you must install the appropriate USB drivers for communication between the computer and system before you install the HiPath 1220 applications. To do this, insert the system CD in your CD drive. You need administrator rights to install software in Windows 2000/XP. 1. Ensure that the HiPath 1220 system is running and the PC is switched on. 2. Use the USB cable to connect the HiPath 1220 system and your computer. 3. A window shows that new hardware was found. The Found New Hardware Wizard appears. Select the Install the software automatically (Recommended) option and confirm with Next. 4. The system searches the system CD for a suitable HiPath 1220 driver (CallBridge for Data Eval). Windows 2000 or Windows XP displays repeated messages stating that it did not find a Microsoft signature associated with the software package you want to install or that the Windows logo test was failed. Confirm these messages with Yes or Continue Setup. 5. In the next window, confirm the installation with Finish. 6. The Found New Hardware Wizard reappears. Select the Install the software automatically (Recommended) option once more and confirm with Next. 7. The system searches the system CD for a suitable HiPath 1220 driver (HiPath 1220 USB interface). Windows 2000 or Windows XP displays repeated messages stating that it did not find a Microsoft signature associated with the software package you want to install or that the Windows logo test was failed. Confirm these messages with Yes or Continue Setup. 8. In the next window, confirm the installation with Finish. You can now start to install the HiPath 1220 applications (see Section 4.3.3, "Software Installation of HiPath 1220 Applications"). Restart your computer after installing the HiPath 1220 applications. 4-4 A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 4_PC_Install.fm Nur für den internen Gebrauch Installing the Computer Software Overview of Software Installation Now, check the CommServer Configuration after the restart. To do this, right-click the CommServer icon in the Windows status bar and select Properties. The settings should be as follows: Connection Type: USB Connection/Tel. no.: ---/Own MSN: --- English Only one of the four installation variants may be installed per computer (see Section 2.5.7, "Connecting HiPath 1220 with the Computer") 7 Your computer is ready for operation see Section 4.4, "Initial Start-Up (Starting HiPath 1220 Manager)". 4.3.3 Software Installation of HiPath 1220 Applications > Only for country versions with USB port!!! If your computer is connected to the HiPath 1220 system with the USB cable supplied, you must install the appropriate USB drivers before installing the HiPath 1220 applications. 1. Is the system CD in your CD drive? If you have not configured a Startup function, select Start | Run in the Windows start menu and click Browse to open the file :\SETUP.EXE on the CD. 2. Select the required language in the Setup window. When you select the required language, the country-specific default settings will be automatically made during installation. 3. Click Installation in the Setup window. The selection window appears with the software you want to install. 4. Now install the required software packages (see Section 4.2, "Computer Software") by clicking the appropriate button. The following programs (at least) are required for operating the HiPath 1220 system. ● HiPath 1220 Manager ● CommServer (automatically installed) To install additional software packages, click the appropriate button and follow the instructions. 5. After installing the individual components, you receive a message that installation was successful. Confirm this message with Finish. Once the required software packages have been installed, you can close the Setup window with Exit. The software is now installed. Please restart the computer. A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 4-5 4_PC_Install.fm Installing the Computer Software Overview of Software Installation 4.3.4 Nur für den internen Gebrauch Software Installation for a Direct Computer <--> HiPath 1220 Connection over USB Using On-Line Services or Software Installation with USB Connection over optiPoint 500 If, in addition to administration of the HiPath 1220 system, you would also like to use on-line services (such as Group 3/4 fax devices, Euro File Transfer, Internet access, etc.) on your computer, you must install special USB drivers and CAPI applications from the "CallBridge for Data" software package for communication between the PC and system. 7 If you have already installed third-party CAPI drivers or an ISDN card on your computer, you must uninstall these completely before you install "CallBridge for Data". As the installation of these components automatically starts with the connection of the USB cable, you must prepare the separately delivered CallBridge for Data software beforehand as follows: ● Ensure that the HiPath 1220 system is running and the PC is switched on. ● Insert the system CD in your CD drive. If a Startup function is configured, minimise the Setup window in the Windows status bar. ● In Windows Explorer, switch to the directory :\Software\CAPI Drivers and open the following file with a double-click: – CAPI_HiPath1220_XXX.exe for a direct computer <--> HiPath 1220 connection, or – CAPI_optiPoint_XXX.exe for a USB connection over optiPoint 500 In the window that opens, use Browse to specify the location for the unzipped "CallBridge for Data" installation software (for example the temporary folder C:\Temp) and start the unzip routine with Unzip. ● Further installation steps are described in the following sections and depend on your operating system: – Section 4.3.4.1, "Installing the USB/CAPI Driver under Windows 98 SE" – Section 4.3.4.2, "Installing the USB/CAPI Driver under Windows ME" – Section 4.3.4.3, "Installing the USB/CAPI Driver under Windows 2000" – Section 4.3.4.4, "Installing the USB/CAPI Driver under Windows XP" – Section 4.3.4.5, "Installing CAPI Applications" 7 4-6 Restart your computer after installing the USB drivers and CAPI applications. A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 4_PC_Install.fm Nur für den internen Gebrauch Installing the Computer Software Overview of Software Installation Perform CommServer Configuration after restarting your computer. To do this, right-click the CommServer icon in the Windows status bar and select Properties. Enter the following settings: ● for a direct computer <--> HiPath 1220 connection ● English Connection Type: USB connection Tel. no.: --Own MSN: --for USB connection over optiPoint 500 Connection Type: ISDN Connection Tel. no.: 800 Own MSN: --● The CommServer must be closed down to apply these settings. Every time you call up a HiPath 1220 application, a new session is automatically started. 7 Only one of the four installation variants may be installed per computer (see Section 2.5.7, "Connecting HiPath 1220 with the Computer") > USB drivers are plug&play. This means that the HiPath 1220 system can be removed from the computer’s system configuration after installation by unplugging the USB connector. Similarly, it can be re-inserted in the system configuration by plugging the USB connector back into the USB port. You do not have to repeat driver installation. The device is immediately ready for operation. A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 4-7 4_PC_Install.fm Installing the Computer Software Overview of Software Installation 4.3.4.1 Nur für den internen Gebrauch Installing the USB/CAPI Driver under Windows 98 SE > You may have to install system components in the course of driver installation. Keep the Windows 98 CD-ROM to hand. 1. Ensure that the HiPath 1220 system is running and the PC is switched on. 2. Use the USB cable to connect the HiPath 1220 system and your computer. 3. The Windows hardware wizard appears. It shows that it is searching for new drivers for a Composite USB device. Confirm the window with Next. 4. Select the Search for the best driver for your device. (Recommended) option and confirm with Next. 5. Select the checkbox Specify a location and use Browse to select the directory in which you unzipped the CallBridge for Data software (for example, C:\Temp, see Section 4.3.4). Confirm the window with Next. 6. A message appears confirming that the best driver for the device was found. Confirm the window with Next. 7. The system confirms that the software for the Composite USB device was installed. Click Finish. 8. A message appears confirming that the system is searching for a driver for HiPath 1220. Repeat device driver installation (steps 3-6) for the following devices: 9. 4-8 ● HiPath 1220 virtual COM ports ● HiPath 1220 (CAPI interface) You must make two more configuration entries while installing HiPath 1220 (CAPI interface): A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 4_PC_Install.fm Nur für den internen Gebrauch Installing the Computer Software Overview of Software Installation English a) Select EURO-ISDN (DSS1) in the following window and confirm with Next. b) Enter a free internal phone number in the Phone number (MSN) field: ● For a direct computer <-> system connection, enter 10 as the phone number. ● For a computer <-> optiPoint 500 <> system connection, enter (41 or 42 or 47 to 52) as the phone number1 as the phone number. To ensure that inbound calls reach the computer (for example to receive a fax), the internal number entered here must be assigned an MSN or DID number in HiPath 1220 Manager. Confirm this entry with Next. The same window appears. Confirm with Next without making any entry. 1 The phone number you should enter as an MSN depends on the port to which the optiPoint 500 system telephone is connected (see Section 2.5.2, "Default Phone Number Allocation"). 10. USB driver installation is now complete. Installing CAPI Applications now starts automatically (see Section 4.3.4.5). A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 4-9 4_PC_Install.fm Installing the Computer Software Overview of Software Installation 4.3.4.2 Nur für den internen Gebrauch Installing the USB/CAPI Driver under Windows ME 1. Ensure that the HiPath 1220 system is running and the PC is switched on. 2. Use the USB cable to connect the HiPath 1220 system and your computer. 3. The Windows hardware wizard appears. It shows that it is searching for new drivers for HiPath 1220. Select the Specify the location of the driver (Advanced) option and confirm with Next. 4. Select the Search for the best driver for your device. (Recommended) option. Select the checkbox Specify a location and use Browse to select the directory in which you unzipped the CallBridge for Data software (for example, C:\Temp, see Section 4.3.4). Confirm the window with Next. 5. A message appears confirming that the system is searching for a driver for CallBridge for Data (Eval). Confirm the window with Next. 6. The system confirms that the software for the CallBridge for Data (Eval) system was installed. Click Finish. 7. A message appears confirming that the system is searching for a driver for HiPath 1220. Repeat device driver installation (steps 3-6) for the following devices: 8. ● HiPath 1220 virtual COM ports ● HiPath 1220 (CAPI interface) You must make two more configuration entries while installing HiPath 1220 (CAPI interface): 4-10 A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 4_PC_Install.fm Nur für den internen Gebrauch Installing the Computer Software Overview of Software Installation English a) Select EURO-ISDN (DSS1) in the following window and confirm with Next. b) Enter the following phone number in the Phone number (MSN) field: ● For a direct computer <-> HiPath 1220 connection, enter 10 as the phone number. ● For a computer <-> optiPoint 500 <-> HiPath 1220 connection, enter (41 or 42 or 47 to 52)1 as the phone number. To ensure that inbound calls reach the computer (for example to receive a fax), the internal number entered here must be assigned an MSN or DID number in HiPath 1220 Manager. Confirm this entry with Next. The same window reappears. Confirm with Next without making any entry. 1 9. The phone number you should enter as an MSN depends on the port to which the optiPoint 500 system telephone is connected (see Section 2.5.2, "Default Phone Number Allocation"). USB driver installation is now complete. Installing CAPI Applications now starts automatically (see Section 4.3.4.5). A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 4-11 4_PC_Install.fm Installing the Computer Software Overview of Software Installation 4.3.4.3 Nur für den internen Gebrauch Installing the USB/CAPI Driver under Windows 2000 You need administrator rights to install software in Windows 2000. 1. Ensure that the HiPath 1220 system is running and the PC is switched on. 2. Use the USB cable to connect the HiPath 1220 system and your computer. 3. A window shows that devices were found. The hardware wizard appears for driver installation. Confirm the window with Next. 4. Select the Search for a suitable driver for my device (recommended) option and confirm with Next. 5. If not already set, select the checkbox Specify a location (right) and confirm the window with Next. 6. A second window appears in which you can use Browse to select the directory in which you unzipped the CallBridge for Data software (for example, C:\Temp, see Section 4.3.4) and confirm with Next. 7. A window shows that a suitable driver was found. Confirm the window with Next. 8. A message appears stating that the software you want to install was not digitally signed by Microsoft. Confirm the message with Yes. 9. Select the port number for the HiPath 1220 virtual COM port in the Select Port Number window (right - COM 3 should be set by default) and confirm with OK. COM3 must not be used for any other device. 10. A message appears confirming that the selected device is installed. Continue with Exit. 4-12 A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 4_PC_Install.fm Nur für den internen Gebrauch Installing the Computer Software Overview of Software Installation 11. The HiPath 1220 (CAPI interface) installation routine then starts. A message appears twice stating that the software you want to install was not digitally signed by Microsoft. Confirm these messages with YES. English 12. Select European ISDN (DSS1) in the ISDN - HiPath 1220 or optiPoint 500 window (right) and confirm with Next. 13. Enter the following phone number in the middle input field and click Add to enter it in the Multi-subscriber numbers field: ● For a direct computer <-> system connection, enter 10 as the phone number. ● For a computer <-> optiPoint 500 <-> system connection , enter ( 41 or 42 or 47 – 52) 1 as the phone number. To ensure that inbound calls reach the computer (for example to receive a fax), the internal number entered here must be assigned an MSN or DID number in HiPath 1220 Manager. Confirm this entry with Next. 1 The phone number you should enter as an MSN depends on the port to which the optiPoint 500 system telephone is connected (see Section 2.5.2, "Default Phone Number Allocation"). 14. USB driver installation is now complete. Installing CAPI Applications now starts automatically (see Section 4.3.4.5). A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 4-13 4_PC_Install.fm Installing the Computer Software Overview of Software Installation 4.3.4.4 Nur für den internen Gebrauch Installing the USB/CAPI Driver under Windows XP You need administrator rights to install software in Windows XP. 1. Ensure that the HiPath 1220 system is running and the PC is switched on. 2. Use the USB cable to connect the HiPath 1220 system and your computer. 3. A window shows that new hardware was found. The Found New Hardware Wizard appears. Select the option Install from a list or specific location (Advanced) and confirm with Next (see also figure for step 8). 4. In the next window, select the checkbox Also browse the following source directory and use Browse to select the directory in which you unzipped the CallBridge for Data software (for example, C:\Temp, see Section 4.3.4) and confirm with Next. 5. The HiPath 1220 driver installation routine then starts. A message appears three times stating that the software you want to install failed the Windows logo test. Confirm these messages with Continue Setup. 6. Select European ISDN (DSS1) in the ISDN - HiPath 1220 or optiPoint 500 window (right) and confirm with Next. 7. Enter the following phone number in the middle input field and click Add to enter it in the Multi-subscriber numbers field: 1 ● For a direct computer <-> system connection, enter 10 as the phone number. ● For a computer <-> optiPoint 500 <-> system connection , enter ( 41 or 42 or 47 – 52)1 as the phone number. The phone number you should enter as an MSN depends on the port to which the optiPoint 500 system telephone is connected (see Section 2.5.2, "Default Phone Number Allocation"). 4-14 A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 4_PC_Install.fm Nur für den internen Gebrauch Installing the Computer Software Overview of Software Installation 8. In the next window, confirm the installation with Finish. 9. The Found New Hardware Wizard reappears. Select the Install from a list or specific location (Advanced) option (right) once more and confirm with Next. English To ensure that inbound calls reach the computer (for example to receive a fax), the internal number entered here must be assigned an MSN or DID number in HiPath 1220 Manager. Confirm this entry with Next. 10. In the next window, select the checkbox Also browse the following source directory and use Browse to select the directory in which you unzipped the CallBridge for Data software (for example, C:\Temp, see Section 4.3.4) and confirm with Next. 11. A message appears twice stating that the software you want to install failed the Windows logo test. Confirm these messages with Continue Setup. 12. Select the port number for the HiPath 1220 virtual COM port in the Select Port Number window (right - COM 3 should be set by default) and confirm with OK. COM3 must not be used for any other device. 13. A message appears confirming that the selected device is installed. Continue with Finish. 14. USB driver installation is now complete. Installing CAPI Applications now starts automatically (see Section 4.3.4.5). A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 4-15 4_PC_Install.fm Installing the Computer Software Overview of Software Installation 4.3.4.5 7 Nur für den internen Gebrauch Installing CAPI Applications If you have already installed third-party CAPI drivers or an ISDN card on your computer, you must uninstall these completely before you install the following software. Since the CAPI application installation routine is similar on all Windows operating systems and very simple, we only provide a general description here. 1. The first window for installing CAPI applications appears when USB driver installation is complete. Select the language you want here and confirm with OK. 2. After confirming the welcome mask with Next, the next setup window appears with the destination path (default setting) in which the CAPI applications (CallBridge for Data Utilities) are installed. You can change this with Browse. Confirm the window with Next. 3. You can create a new Tool folder in the window that appears next or select Existing folders as the location where you want to save the program icons for starting the relevant applications. Confirm your entries with Next to complete the installation routine. End the installation routine with Exit. After installing the USB connection over optiPoint 500 (CAPI_optiPoint_XXX.exe) you are prompted to enter a CD key which allows you to use CallBridge for Data without restriction for 30 days. You will find four CD keys on the inside of the system housing cover. For a detailed description of registration and information on how to obtain the permanent serial number, see Section 3.6.1.3 Registration in the CallBridge for Data documentation (see Chapter 5, "System CD Documentation"). 7 Restart your computer after installing the USB drivers and CAPI applications (CallBridge for Data Utilities). The following applications are installed on your PC: ● Wizards for ISDN Configuration (Windows 98 SE/ME) ● CAPI Monitor ● Uninstallation ● FaxComm+ Installation ● Loopback Test ● Configuration of the outgoing number (MSN) (Windows 2000/XP) For more details on program configuration and implementation, see Chapters 4 and 5 of the CallBridge for Data documentation (see Chapter 5, "System CD Documentation"). 4-16 A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 4_PC_Install.fm Installing the Computer Software Overview of Software Installation Nur für den internen Gebrauch 4.3.4.6 On-Line Services and Fax Application Programs ● 5.1 Setting up a dial-up connection ● 5.2 On-line services ● 5.3 Fax application programs English For more information on this topic, see the following sections in the documentation on CallBridge for Data: (see Chapter 5, "System CD Documentation"). 4.3.5 Uninstalling Software For S0 connections complete steps 1, 6 and 7. For USB connections follow steps 1 to 7. 1. Close the CommServer by right-clicking the Exit. icon in the Window status bar and selecting 2. Close any open CallBridge for Data on-line services. 3. Disconnect the USB cable used for connecting the HiPath 1220 system to your computer. 4. Uninstall the installed USB drivers as follows: Select Start --> Settings --> Control Panel --> System --> tab (Hardware in Windows 2000/XP) to open the Device Manager. Click "+" or double-click USB Controller to display the drop-down list of USB drivers installed, right-click CallBridge for Data (Eval)--> Remove/Uninstall and confirm with OK. Then right-click HiPath1220 Interface --> Remove/Uninstall and confirm again with OK. 5. If you installed CallBridge for Data Utilities for using on-line services or for USB connection, uninstall it now by activating the uninstallation program with: Start/Programs/CallBridge for Data Utilities/ Uninstall CallBridge for Data Utilities After uninstalling CallBridge for Data Utilities, answer No to the prompt Do you want to restart your computer now? and proceed with step 6. 6. Uninstall all HiPath 1220 components with: Start/Settings/Control Panel/Add/Remove Programs and click Remove Software. 7. Then restart your computer. A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 4-17 4_PC_Install.fm Installing the Computer Software Initial Start-Up (Starting HiPath 1220 Manager) 4.4 Nur für den internen Gebrauch Initial Start-Up (Starting HiPath 1220 Manager) To start HiPath 1220 Manager, select the following in your PC start menu: Start/Programs/Siemens/HiPath 1220/Service/HiPath 1220 Manager Select the checkbox Demo Mode and OK (without entering a password) for a detailed view of the configuration of HiPath 1220 Manager and to get to know the look and feel of the system. When logging on to HiPath 1220 Manager for the first time, use the default password "31994". 7 The default password (programming password) should be changed after you log on to the HiPath 1220 Manager for the first time. The first time you start the HiPath 1220 Manager, the Installation Wizard appears for making basic settings. Use the Next and Back buttons to switch from one input mask to another. Every time you use Next to quit an input mask containing new entries you are asked if you want to update your changes. The following input masks are available: ● Configuration input mask: enter multiple subscriber numbers (MSN) for your ISDN port. ● Day input mask: assign MSNs to extensions for day mode. 4-18 A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 4_PC_Install.fm Installing the Computer Software Starting Other Computer Applications (For Default Installation) ● Night input mask: assign MSNs to the extensions for night mode. ● Phone book input mask: create a central phone book. ● Extension input mask: assign names to the extensions. ● Call Charge Accounts input mask: assign charge limits. ● Click End to see the default view of HiPath 1220 Manager. This view now appears every time you open HiPath 1220 Manager. See the HiPath 1220 Manager documentation for more information and details on how to change the default configuration of your HiPath 1220 system (see Chapter 5, "System CD Documentation"). 4.5 ● Starting Other Computer Applications (For Default Installation) Accounting Manager (optional): call charge evaluation software. To start the Accounting Manager, select the following in the start menu on your computer: Start/Programs/Siemens/HiPath 1220/Accounting/Accounting ● Software Update Wizard (optional): wizard for updating the system software. To start the Software Update Wizard, select the following in the start menu on your computer: Start/Programs/Siemens/HiPath 1220/Service/HiPath 1220 SW Update ● LED Status Display (optional): LED status display on the computer. To start LED Status Display, select the following in the start menu on your computer: Start/Programs/Siemens/HiPath 1220/Service/HiPath 1220 LED Status ● MoH Transfer Wizard (optional): MIDI transfer wizard for converting MIDI files into the HiPath 1220 format and transferring them to the system. To start the MIDI transfer wizard, select the following in your computer’s start menu: Start/Programs/Siemens/HiPath 1220/Service/HiPath 1220 MoH Transfer See Chapter 5, "System CD Documentation", for more information on HiPath 1220 system documentation. A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 4-19 English Nur für den internen Gebrauch 4_PC_Install.fm Installing the Computer Software Starting Other Computer Applications (For Default Installation) 4-20 Nur für den internen Gebrauch A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual Nur für den internen Gebrauch 5 5_aDoku.fm System CD Documentation System CD Documentation You can access the following documentation and programs from the documentation start page (see figure below) on your HiPath 1220 system CD: ● HiPath 1220 Installation Manual (PDF format) ● HiPath 1220 Manager Documentation (PDF format) ● Accounting Manager Documentation (PDF format) ● Installation Manual for optiPoint Key Modules, Adapters and Accessories (PDF format) ● Operating Manual for optiPoint 500 economy/basic/standard/advanced 1 ● Operating Manual for optiPoint 500 entry 1 ● Operating Manual for Analogue Telephones1 ● Operating Manual for ISDN Telephones1 ● Installation and Administration Manual for CallBridge for Data (PDF format) English Documentation Programs ● optiPoint key labelling ● Adobe Reader Installation 1 These operating manuals are available on the system CD in PDF or HTML format. To access this documentation: 1. Insert the system CD in your CD drive. If you have not configured a Startup function, select Start | Run in the Windows start menu and click Browse to open the file :\SETUP.EXE on the CD. 2. Select the required language (German or English) in the Setup window. 3. Click Documentation in the Setup window. You can select the documentation you want in the browser window that appears (right). A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 5-1 5_aDoku.fm System CD Documentation 5-2 Nur für den internen Gebrauch A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual 5_bTechDat.fm Technical Data Nur für den internen Gebrauch 6 Technical Data Power supply Dimensions/weight 110 V - 230 V ~, 50 Hz Housing (W x L x H) 34.5 x 28.5 x 9 cm Power consumption max. 30 VA Weight approximately 1500 g Nominal current max. 1000 mA Security EN 60950, CE Weight approximately 250 g Trunk connection (S0 external) Connection type Terminating resistor ISDN subscriber line (S0 internal) 2 x S0 basic access as Connection type multi-device connection or as TC system port, Devices DSS1 protocol (EUROISDN), system is powered locally Range 2 x 100 in final wall outlet 1 S0 port, EURO-ISDN (DSS-1) max. 8 ISDN devices with internal power supply 100 m (when relocating an internal S0 bus) Analogue subscriber line optiPoint 500 system telephones Open-circuit voltage max. 18 Vdc Open-circuit voltage max. 33 Vdc Loop current approximately 26 mA Loop current Range 2 x 50 Ω, approximately Range 150 m Ring voltage approximately 33 V 50 Hz sym. A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual English Line voltage max. 46 mA 2 x 50 Ω, approximately 150 m 6-1 5_bTechDat.fm Technical Data 6-2 Nur für den internen Gebrauch A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual Nur für den internen Gebrauch Begriffe1.fm Abbreviations Abbreviations Y This list includes the abbreviations used in this documentation. Definition CAPI Common ISDN Application Program Interface DSS1 European Digital Subscriber Signalling No. 1 DID Direct Dialling EM Expansion Module EURO European currency EURO-ISDN ISDN default with DSS1 protocol ISDN Integrated Services Digital Network LED Light Emitting Diode LPSU Local Power Supply Unit MFXAS Expansion module with two sensors, two relays for alarm generation and management and one interface for playing external music MIDI Musical instrument digital interface MOH Music on Hold (MOH) Music on Hold MPXU Expansion module with two UP0/E interfaces (requirement: the HiPath 1220 system is fitted with the MSC system expansion module) MPXA Expansion module for two analogue interfaces MSC Basic module for the HiPath 1220 system MSN Multiple Subscriber Number MSX System expansion module for the digital expansion including two UP0/E interfaces NTBA Network Termination (of) Basic Access; for connecting to the public network in ISDN PSU Power Supply Unit for HiPath 1220 RAM Random Access Memory S0 SW English Abbreviation ISDN subscriber interface (64 KBit) Software A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual Y-1 Begriffe1.fm Abbreviations Nur für den internen Gebrauch Abbreviation Definition TEA Telecommunication Adaptor Equipment USB Universal Serial Bus; universal serial interface on computers for connecting printers, scanners, keyboards, mouse devices, etc. Y-2 A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual HP1220_MaInstallIX.fm Index Nur für den internen Gebrauch Index Z A P Adapters 2-8 Analogue configuration variants 3-2 Password 1-3, 4-18 Phone number allocation, overview 2-6 Power supply unit 2-5 C CD key 4-16 CE mark 1-6 CommServer 2-11 Communication server 2-11 Configuration or expansion 3-1 Contents of the package 1-7 R Registration 4-16 Relay interfaces 3-8 S E S0 bus port 2-5 Safety information 1-5 Safety symbols 1-5 Sensor interfaces 3-7 Slots for expansion 2-5 Software installation, overview 4-2 System cables, connecting 2-5 System interfaces 2-5 Expansion module MFXAS 3-7 External music-on-hold facility 3-8 T F Technical data 6-1 Tools required 1-8 Fax receipt 4-9, 4-11, 4-13, 4-15 Full configuration 3-3 U H USB connection variants 2-12 USB port 2-5 D Default password 4-18 Default phone number allocation 2-6 Digital configuration variants 3-2 HiPath 1220 manager password 4-18 I W Wall mounting 2-4 Installation wizard 4-18 ISDN S0 connection variants 2-12 L LPSU, local power supply unit 2-5 M MPXA expansion module 3-6 MPXU expansion module 3-5 MSC base module 3-4 A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual Z-1 HP1220_MaInstallIX.fm Index Z-2 Nur für den internen Gebrauch A31003-H1100-A106-3-X931, 04/2004 HiPath 1220, Installation Manual