HM756C
TRANSFORMER FULLY-AUTOMATIC UNIT HM756C_R26 is a fully-automatic, six-channel heat treatment unit for preheating and annealing metal workpiece. Output power of the model HM756C_R26 is contactor controlled. Stainless steel casing gives long liftime. Setting, control, monitoring and documentation of heat treatment parameters are carried out by the computerized Heatmasters’ Control System. HM756C_R26 provides accurate heat treatment and easy documentation. HM756C_R26 can be remotecontrolled by gsm data line or radio modems.
PROGRAMMING
HM756C
TRANSFORMER
Heat treatment parameters are programmed in the memory of the HM-Rigel26 controller using HM20 software and heating can be started at any desired time. HM756C_R26 will carry out the programmed heat treatment process according to the given phases. The process can be minitored using a laptop or following the status from the controller. DATA REGISTRATION The controller registers the achieved heat treatment results in its memory, which enables easy preparation of heat treatment documents. A separate temperature recorder is not needed. CAPACITY HM756C_R26 has six heating channels and six independent programming alternatives. The signal lights of HM756C_ R26 will indicate any disturbances in the electric network and/or in the heating elements, as well as any other disturbances during the heat treatment.
HM756C_R26
BASIC EQUIPMENT HM756C_R26 Basic equipment combination of HM756C_R26 includes items mentioned in table below HM756C_R26 equipment
HM756C_R26 -standard combination: Qty Code A 1 001001
Product HM756C_R26 heat treatment unit
B 1 1300502 Data cable between the PC and the heating unit C 1 HM20 software (PC) D 6 10100
Secondary cable set 100 ft - Cable size #2
E 12
3-Way splitter, 4 ft - Cable size #6
5010200
F 18 02xxxx Heating elements
Secondary cables are marked with channel number to avoid wrong connections. Heat treatment certificates can be printed with a normal office printer from the PC`s memory.
G 6 080x Thermocouple wire
ACCESSORIES USED WITH HM756C_R26 UNIT Following optional accessories are available for HM756C_R26 heat treatment equipment: Code Product 5010300
Compensating cable-100 ft Additional cable when using two measuring points in one channel
5010102
Secondary cable extension set - L = 100ft - Incloude compensating cable
5040001
Primary receptacle, 200A - Panel mount, Meltric
5040002
Primary receptacle, 200A - Plug, Meltric
5040011
Primary receptacle, 200A - Panel mount, Appelton
5040012
Primary receptacle, 200A, - Plug, Appelton
Compensating cable-100 is a single cable for extra T/C of the heating channel. The cable can be integrated to the secondary cable set if so required. Standard length of secondary cable set is 100ft and it can be extended with cable sets mentioned in table. Cables are made of several sets, so they are easier to handle.
Primary conecton can be offered by easy and safe operation, whitout electrical hazards using receptacle.
HM-Rigel26-GSM set enables wireless contact to the heating unit from the PC, alarms to gsm phone and to receive information of the status of the heating process to the gsm phone.
3900557
HM-Rigel26-GSM set Enables longdistance control and alarms
3900534
HM-Rigel26-RK6 card Enables six extra measuring points
HM-Rigel26-RK6 card enables to measure and record temperature from six extra measuring points. The feature is for recording only.
5102006
Radio modem set
1300506
USB-RS232 adapter
Radio modem technology gives possibility for wireless connection between the PC and the heating unit. This solution is mostly used on site operations. Depending of the enviroment and used antenna the distance can be over 60 miles.
HM756C_R26 TECHNICAL DATA Connection voltage
480V / 3-phase / 60Hz
Nominal power
75 kVA; ED 100%
Fuse
125A
Secondary voltage
80V
Main switch
With ground fault (circuit) interrupter
Heating channels
6 x 150A
Additional outputs
2 x 120V, 10A
Heating elements
18 heating elements with maximum power of 3,6 kW can be connected. Three elements per channel
Temperature range
68 ... 1922°F
Control system
HM-Rigel26 controller with HM20 software
Alarm system
Signal lights Optional remotely alarm to a mobile phone when using HM-Rigel26 GSM alarm card
Dimensions Length, inch
30
Width, inch
30
Height, inch
36
Weight, lbs
996
TOOLS NEEDED IN THE HEAT TREATMENT WORK Following tools and consumables are necessary in most heat treatment operations with HM756C_R26 and other heat treatment units:
HM190 T/C attachment unit including leather case
Code
Product
5030510
HM190 T/C attachment unit including leather case
5030804 Thermocouple wire K-type, Q/Q-20-KK, AWG 20 heat resistance up to 1600°F, 1 coil = 1000ft 5030805 Thermocouple wire, K-type, CEF-20-KK, AWG 20 heat resistance up to 2400°F, 1 coil = 1000ft 5700502 anding tool 5700505
Thermocouple wire
Glass fiber tape
5700506 teel band 3/4', 100ft 5700507
Case for steel band
5700508 and clip (100 pcs/pack) 5801506
Ceramical wool, 6 lbs, 2300°F, 300'x24'x1'
5801508
Ceramical wool, 8 lbs, 2300°F, 300'x24'x1'
Accessories Code Product 1300506 USB-RS232 adapter
Steel band and banding tool
www.heatmasters.net