Preview only show first 10 pages with watermark. For full document please download

Hms1655l

   EMBED


Share

Transcript

LON NATIVE FUME HOOD CONTROLLER PRIMARY FEATURES / BENEFITS Closed loop control - measures and controls based on hood face velocity with or without sash height. to display important hood parameter including sash height. Dedicated velocity flow sensor input, and a second input, provides for real-time readings with a high degree of reliability. OTHER FEATURES INCLUDE: • Multiple alarms for face velocity & sash • Programmable, full color, touch screen display • Closed-loop system with options to use sash and/or sidewall feedback for control or monitoring • Zone Presence Sensor (ZPS) support • Sash energy savings support • Multi-trigger emergency purge • Non-volatile memory • Linear or PID output • Network integrateable with other 1650/55L room controllers for total space offset/pressure control Safety Halo™ edge lighting technology increases hood status viewing to 180°. Safety Halo intensity is fully programmable to dim for night hours or can be shut off completely Flexible Design - linear or PID output for increased functionality and compatibility. Programmable audible and visual alarms increases warning and alarms status notifications at a glance. Configurable and programmable screen can be set w w w . t r i a t e k . c o m Action Icon Warning System TRIATEK HMS-1655L TRIATEK HMS-1655L Specifications Alarm Range 0-200 fpm Display Range 0-200 fpm (0-1.016 m/s) Accuracy ±2 FPM @ 60-140 fpm, ±5 FPM outside this range Sidewall sensor (0-1.59 Pa) Sash Position Sensor Vertical height (0-43 in) Control Capability Sash position w/ sidewall sensing feedback for closed-loop Calibration 2-pt (zero & target setpoint); field calibration feature Low Air Flow Alarm Fully Programmable w/ Low Sash Mute Analog Inputs 4 Universal (0-5V, 0-10V) Analog Outputs 4 Universal (4-20mA, 0-5V, 0-10V) Digital Inputs 4 Active-High or Low Relay Outputs 4 Relay Outputs Native Protocols LONworks native Emergency Purge Touch screen, digital input, via network front end Sash High Indication Sash position or sash switch Power Requirement Display - Visual Standby Mode Isolated Universal 120/240 VAC to 24 VAC, 60/50 Hz Full Color 3.2" Touch Screen Display w/ intuintive menu system Alarm Indication 4 Color, Audible alarm, "Action" icons Alarm Silence Directly from touch screen, programmable silent period Mounting Normal Mode Surface Mount (no cutout required) Operating Temp. 32-125 °F Outside Dimensions 4.875" x 3.188" x 1" Agency Listings UL 61010-1, FCC Part 15 ETL LISTED ENERGY MANAGEMENT EQUIPMENT CONFORMS TO ANSI/UL 916 Triatek Venturi Valve HMS 1600 Controller Alarm Mode Part Number Guide: Fast Acting Electronic Actuator HMS 1600 Air Flow Sensor HMS1655L -- Sensor Type 1 = single smart sidewall sensor 2 = dual smart sidewall sensor A = single legacy sidewall sensor B = dual legacy sidewall sensor Options for Sash Sensor blank = no sash sensor S = sash position sensor included HMS Display & Alarm Annunciator Typical Fume Hood Equipped with TRIATEK Controls 4487 Park Drive, Suite A-2 • Norcross, GA 30093 Phone: (888) 242-1922 or (770) 242-1922 • www.triatek.com Product specifications are subject to change without notice. TRIATEK is a registered trademark of Triatek LLC. 04012013 Air Flow Sensor