Transcript
LON NATIVE FUME HOOD CONTROLLER PRIMARY FEATURES / BENEFITS Closed loop control - measures and controls based on hood face velocity with or without sash height.
to display important hood parameter including sash height.
Dedicated velocity flow sensor input, and a second input, provides for real-time readings with a high degree of reliability.
OTHER FEATURES INCLUDE: • Multiple alarms for face velocity & sash • Programmable, full color, touch screen display • Closed-loop system with options to use sash and/or sidewall feedback for control or monitoring • Zone Presence Sensor (ZPS) support • Sash energy savings support • Multi-trigger emergency purge • Non-volatile memory • Linear or PID output • Network integrateable with other 1650/55L room controllers for total space offset/pressure control
Safety Halo™ edge lighting technology increases hood status viewing to 180°. Safety Halo intensity is fully programmable to dim for night hours or can be shut off completely Flexible Design - linear or PID output for increased functionality and compatibility. Programmable audible and visual alarms increases warning and alarms status notifications at a glance. Configurable and programmable screen can be set
w w w . t r i a t e k . c o m
Action Icon Warning System
TRIATEK HMS-1655L
TRIATEK HMS-1655L Specifications Alarm Range
0-200 fpm
Display Range
0-200 fpm (0-1.016 m/s)
Accuracy
±2 FPM @ 60-140 fpm, ±5 FPM outside this range Sidewall sensor (0-1.59 Pa)
Sash Position Sensor
Vertical height (0-43 in)
Control Capability
Sash position w/ sidewall sensing feedback for closed-loop
Calibration
2-pt (zero & target setpoint); field calibration feature
Low Air Flow Alarm
Fully Programmable w/ Low Sash Mute
Analog Inputs
4 Universal (0-5V, 0-10V)
Analog Outputs
4 Universal (4-20mA, 0-5V, 0-10V)
Digital Inputs
4 Active-High or Low
Relay Outputs
4 Relay Outputs
Native Protocols
LONworks native
Emergency Purge
Touch screen, digital input, via network front end
Sash High Indication
Sash position or sash switch
Power Requirement Display - Visual
Standby Mode
Isolated Universal 120/240 VAC to 24 VAC, 60/50 Hz Full Color 3.2" Touch Screen Display w/ intuintive menu system
Alarm Indication
4 Color, Audible alarm, "Action" icons
Alarm Silence
Directly from touch screen, programmable silent period
Mounting
Normal Mode
Surface Mount (no cutout required)
Operating Temp.
32-125 °F
Outside Dimensions
4.875" x 3.188" x 1"
Agency Listings
UL 61010-1, FCC Part 15
ETL LISTED ENERGY MANAGEMENT EQUIPMENT CONFORMS TO ANSI/UL 916
Triatek Venturi Valve
HMS 1600 Controller
Alarm Mode
Part Number Guide: Fast Acting Electronic Actuator
HMS 1600 Air Flow Sensor
HMS1655L
--
Sensor Type 1 = single smart sidewall sensor 2 = dual smart sidewall sensor A = single legacy sidewall sensor B = dual legacy sidewall sensor
Options for Sash Sensor blank = no sash sensor S = sash position sensor included
HMS Display & Alarm Annunciator
Typical Fume Hood Equipped with TRIATEK Controls
4487 Park Drive, Suite A-2 • Norcross, GA 30093 Phone: (888) 242-1922 or (770) 242-1922 • www.triatek.com
Product specifications are subject to change without notice. TRIATEK is a registered trademark of Triatek LLC. 04012013
Air Flow Sensor