Preview only show first 10 pages with watermark. For full document please download

Home Overview

   EMBED


Share

Transcript

OVERVIEW and SYSTEM GUIDE Swegon CASA ® Residential ventilation for optimal operating economy and the greatest comfort. www.swegon.com Swegon CASA Swegon – your system supplier Ventilation unit Vapour barrier for duct penetrations Mounting frame with vapour barrier Supply air diffuser Sound attenuator Extract air diffuser Cooker hood Swegon can offer specific products in most product areas that deal with air handling. However, the end user will benefit mostly from our products if they are supplied in the form of system solutions. We then take responsibility to ensure that the products are simple to install, save floor space and operate in harmony to provide the highest possible degree of comfort and use the least possible amount of energy. Cooker hoods Swegon CASA is a complete system for residential ventilation. Components from a single supplier guarantee that all units work together in a system and that correctly dimensioned products are available. For example, several ventilation units can be controlled from the cooker hood panels. Swegon personnel are there to help you with customised system solutions for specific applications as required. Mounting frames with vapour barrier Ventilation units 2 Air diffusers Sound attenuator Swegon reserves the right to alter specifications. Swegon CASA Energy efficient fans with EC motors The unit’s fans are equipped with state-of-the-art EC motors. EC-motors are energised with alternating current and the built-in electronics convert this to direct current that makes the motor rotate. The advantage of EC motors is the integrated motor control that can be variably controlled and high efficiency even when they operate in the lower speed range. Generally, other types of motors or controls bring about losses, which are especially noticeable when operating at low speeds. Straightforward and economical installation Installation of the ventilation unit is quick and easy and with that cost effective. Units can be wall mounted or suspended from the ceiling. Wall mounting bracket included either as standard or as an accessory. The ceiling mounting frame, available as an accessory for small units, makes it possible to complete duct routing and install the unit at any time. RECOtite prevents freezing. Heat exchanger R85 is equipped with the patent pending innovation RECOtite. It ensures the correct pressure balance between the supply and extract air seal, which might otherwise be a problem for small airflows. This prevents unwanted moisture leakage and as a result minimizes the risk of freezing in the heat exchanger. A high SFP (Specific Fan Power) and low noise level are also realised as no extra pressure is needed in the extract air duct to prevent leakage. Swegon reserves the right to alter specifications. 3 Swegon CASA A cooker hood can be connected to the unit Ventilation units in smaller sizes have an extra duct connection for connection to a cooker hood. This gives a cost-effective installation as there is no need of an extra fan, extract air duct and roof penetration and roof hood for the cooker hood. Outdoor air Supply air Extract air Exhaust air Extract air from the cooker hood The extract air from the cooker hood does not pass the heat exchanger, but instead is extracted directly out via the extract air fan. As an option, the ventilation unit can be controlled from a separate control panel or from the cooker hood panel. Economical water-borne reheating All ventilation units in the W-series are available in Econo designs with a water-borne air heater instead of an electric air heater. Econo is an economic alternative when the home has a water-borne heating system with radiators or underfloor heating. The water-borne air heater in the unit can be switched on as an extra radiator or an extra circuit for underfloor heating, which gives a more economical heating means than with an electric air heater. Venting valves Thermostat valve Basic circuit diagram Heating water return line Ventilation units model Econo Heating water supply line Air heater Radiator Underfloor heating 4 Heating boiler, heat pump, district heating substation, etc. Swegon reserves the right to alter specifications. Swegon CASA Heat recovery that makes you the winner RECOnomic rotary heat exchanger Counter-flow plate heat exchanger The RECOnomic rotary heat exchanger consists of a rotating wheel made of aluminium foil composed of a multitude of small ducts. The warmer extract air heats the ducts and transfers heat to the colder supply air. The temperature efficiency is approx. 85% when the supply and extract air flows are the same. Counterflow plate heat exchangers consist of thin aluminium plates that form parallel air ducts arranged at right angles to one another. The warmer extract air heats the plates and transfers heat to the colder supply air. The contact surfaces are large because the air streams flow in parallel and in opposite directions. Advantages of rotary heat exchangers The temperature efficiency is approx. 85% when the supply and extract air flows are the same. • High annual efficiency as freezing rarely occurs. • Even a certain amount of moisture, removed with the extract air, is recovered to the supply air. This is especially beneficial in the winter when the outdoor air can be very dry and result in problems for people and interior fittings. To consider: • Outdoor temperatures below zero and a high indoor moisture load can bring about freezing in the heat exchanger’s air ducts. This causes the automatic anti-freeze protection to lower the speed of the supply air fan, giving the heat exchanger a surplus of warm extract air. During this period, there is a negative pressure in the home. • If the home has a high moisture load, the extract airflow must be sufficient to remove the moisture. Humidity sensors (accessory that automatically boost the unit’s fans) are recommended where the moisture load can be high, for example, in a utility room. • Since the same surfaces in the heat exchanger come into contact with both the extract air and the supply air, there is some risk for odour transfer, but in a home with its own ventilation unit, this is normally no problem. Outdoor air Supply air Swegon reserves the right to alter specifications. Extract air Advantages of counterflow plate heat exchangers • No motor to drive the heat exchanger. • The Econo model permits economic reheating with the help of the property’s water-borne heating system. • The supply air and extract air have completely separate air ducts so any possible odours in the extract air cannot be transferred to the supply air. To consider: • Outdoor temperatures below zero and a high indoor moisture load can bring about freezing in the heat exchanger’s exhaust air section. An automatic anti-freeze protection then lowers the speed of the supply air fan and electric preheating is activated. In addition to the negative pressure in the residence, the air heaters for pre-heating and reheating are loaded. • The heat exchanger cannot recover moisture. Exhaust air 5 Swegon CASA Solutions for detached and terrace houses Cooker hood to the ventilation unit. Installation and investment costs will be lower if the ventilation unit’s extract air fan is also used for the cooker hood. However, it does not affect heat recovery as the extract air from the cooker hood does not go through the heat exchanger. One consequence will be that the ventilation unit’s extract air fan needs to be cleaned once or twice a year, but this is also necessary with a separate or integrated fan for the cooker hood. When using the Premium cooker hood the negative pressure is automatically compensated for through increasing the speed of the ventilation unit’s supply air fan. Alternative A The ventilation unit can be placed in a utility room or the like. The cooker hood is connected via the duct (which must be cleanable) to the unit. B A • Cost effective installation as the cooker hood does not need a separate fan, extract air duct, roof penetration or roof hood. R85/120, W80/100 Alternative B Renovation alternative to replace old spice rack fans or kitchen air handling unit. The ventilation unit R85 is installed as a top cabinet above the cooker and the cooker hood is connected directly to the bottom of the ventilation unit. R85 • Cost effective installation as the cooker hood does not need a separate fan, extract air duct, roof penetration or roof hood. Alternative C C D The ventilation unit W130 is placed in a technical room or the like. Circulation air means heat from e.g. a fireplace stove is utilised. The cooker hood has its own extract air duct with power roof ventilator. • Cost effective use of circulation air. Alternative D W130 The ventilation unit W 230 is placed in a technical room or the like. The cooker hood has its own extract air duct with power roof ventilator. Outdoor air 6 Supply air W230 Extract air Exhaust air Circulation air Swegon reserves the right to alter specifications. Swegon CASA Decentralised solutions for apartment buildings Cooker hood to the ventilation unit. See the previous page, the same principle applies for apartment buildings as for detached and terrace houses. However, local restrictions may apply to apartment buildings with respect to cooker hoods being connected to the ventilation unit. Main ducts for extract air or not? It may be cost effective to use main ducts for extract air. You should be aware however that separate measures may be necessary to prevent air transfer, crosstalk and for fire protection. A joint power roof ventilator also requires pressure control. Separate extract air for each apartment through the facade is also a possible solution, yet local restrictions against this may apply. Alternative E The ventilation unit can be placed in a utility room, stairwell or the like. The cooker hood is connected via the duct (which must be cleanable) to the unit. • Cost effective installation as the cooker hood does not need a separate fan, extract air duct, roof penetration or roof hood. Alternative F Renovation alternative to replace old spice rack fans or kitchen air handling unit. The ventilation unit R85 is installed as a top cabinet above the cooker and the cooker hood is connected directly to the bottom of the ventilation unit. • Cost effective installation as the cooker hood does not need a separate fan, extract air duct, roof penetration or roof hood. Alternative G G The ventilation unit can be placed in a utility room, stairwell or the like. The cooker hood has its own extract air duct with a pressure controlled power roof ventilator. E F R85/120, W80/100 R85/120, W80/100 R85 Outdoor air Swegon reserves the right to alter specifications. Supply air Extract air Exhaust air 7 Swegon CASA Centralised solutions for apartment buildings Home Solution Central Home Solution Central is a system solution where the centrally placed ventilation unit serves the required number of apartments with supply and extract air via main ducts or shafts. An appropriate ventilation unit is selected from the Swegon GOLD range. The ventilation unit is pressure controlled and the airflow is regulated in each apartment via the control damper, which is controlled by a timer and presence detectors. Allowing an economical low flow when no one is at home. The cooker hoods have their own extract air duct with a pressure controlled power roof ventilator that serves the required number of apartments. The cooker hood’s extract airflow is compensated automatically with increased supply air and reduced extract air via the control damper. The residents do not need to worry about the indoor climate in the apartment, everything is performed automatically. WISE Apartment Solution for renovation WISE Apartment Solution is a special solution for the renovation of apartment buildings. A centrally placed ventilation unit serves the required number of apartments with supply and extract air via main ducts or shafts. An appropriate ventilation unit is selected from the Swegon GOLD range. The ventilation unit is pressure controlled and the airflow to each apartment is regulated via an intelligent technical box that adjusts the airflow automatically according to signals from air quality and moisture sensors. At the same time as this involves maximum comfort for both individuals and the building, it also means energy efficient operations, where you ventilate just as much as needed, no more or no less. The main installation in each apartment is placed in the hall, only the openings for the air diffusers need to be made in the different rooms. A prefabricated duct cover provides discreet coverage of ducts and drill holes, at the same time as it is quick and easy to install on site. In many instances, the installation can be performed without subsequent repair or painting in the apartment. An integrated fire solution and a smart distribution box for each floor are other examples of time and cost-saving advantages of the WISE Apartment Solution. 8 Swegon reserves the right to alter specifications. Swegon CASA Quick Guide Swegon CASA with rotary heat exchanger R85 R120 Supply air Extract air Outdoor air Exhaust air K Extract air, cooker hood Dimensions and duct connections, Model R, right-hand (model L, left-hand, is horizontally reversed) Height 700 Height 597 Bottom Max. airflow 85 l/s (305 m3 /h) 120 l/s (430 m3 /h) Colour White, RAL 9016 (corresponds to NCS S1002-G50Y) As standard, the cover plate for the front panel is white. Available as an accessory in stainless steel. White, RAL 9016 (corresponds to NCS S1002-G50Y) Weight 55 kg 78 kg In areas warmer than +10°C. Wall mounting bracket included as standard. Suspension kit with duct connections for ceiling/wall mounting available as an accessory. In areas warmer than +10°C. Wall mounting bracket included as standard. Suspension kit with duct connections for ceiling mounting available as an accessory. Direct driven radial fans with EC motors. Direct driven radial fans with EC motors. Installation Fans Filter Reheating Filter class F7 for supply air and extract air. Filter class F7 for supply air and extract air as well as extra filter G3 for supply air. Electric 500 W, can be ordered as a factory-fitted accessory. Electric 800 W, can be ordered as a factory-fitted accessory. Premium. Also see the separate table. Premium. Also see the separate table. Premium control panel Accessories: Included as standard Heat recovery Max. degree of efficiency Up to 85% Up to 85% 125 Pa 175 Pa 250 W/1.1 A 250 W/1.1 A 2.3 m power cord with plug to earthed outlet socket 1 phase 230 V, 50 Hz, 10 A 2.3 m power cord with plug to earthed outlet socket 1 phase 230 V, 50 Hz, 10 A Control system Available pressure for SFP v 2.0 at 70% of the max. airflow Rated output (without electric reheating) Power connection Swegon reserves the right to alter specifications. 9 Swegon CASA Quick Guide Swegon CASA with counterflow plate heat exchanger W80 W100 W130 W230 Height 493 Height 493 Height 1048 100 l/s (360 m3 /h) 115 l/s (415 m3 /h) 130 l/s (470 m3 /h) 230 l/s (820 m3 /h) Colour White, RAL 9016 (corresponds to NCS S1002G50Y) White, RAL 9016 (corresponds to NCS S1002G50Y) White, RAL 9016 (corresponds to NCS S1002G50Y) White, RAL 9016 (corresponds to NCS S1002G50Y) Weight 47 kg 47 kg 85 kg 155 kg Supply air Extract air Outdoor air Exhaust air Circulation air K Extract air cooker hood Dimensions and duct connections model R, right-hand (model L, left-hand, is horizontally reversed) Max. airflow Installation Height 1312 In areas warmer than In areas warmer than In areas warmer than In areas warmer than +10°C. +10°C. +10°C. +10°C. Floor base with a height Floor base with a height Wall mounting bracket or Wall mounting bracket included as standard. that clears a water trap is that clears a water trap is suspension kit with duct Suspension kit with duct available as an accessory. available as an accessory. connections for ceiling mounting available as an connections for ceiling mounting available as an accessory. accessory Fans Direct driven radial fans with EC motors. Direct driven radial fans with EC motors. Direct driven radial fans with EC motors. Direct driven radial fans with EC motors. Filter Filter class F7 for supply air and G3 for extract air as well as extra filter G3 for supply air. Filter class F7 for supply air and G3 for extract air as well as extra filter G3 for supply air. Filter class F7 for supply air and G3 for extract air as well as extra filter G3 for supply air. Filter class F7 for supply air and G3 for extract air as well as extra filter G3 for supply air. Reheating Electric 500 W. Electric 500 W. Electric 900 W. Electric 900 W. Or factory fitted water coil. Or factory fitted water coil. Or factory fitted water coil. Or factory fitted water coil. Pre-heat Control system Electric 1000 W Electric 1000 W Electric 1000 W Electric 750 W Premium. Premium. Premium. Premium. Also see the separate table. Also see the separate table. Also see the separate table. Also see the separate table. Premium control panel Accessories Included as standard Included as standard Included as standard Heat recovery Max. degree of efficiency Up to 85% Up to 85% Up to 85% Up to 85% Available pressure for SFP v 2.0 at 70% of the max. airflow 225 Pa 140 Pa 175 Pa 175 Pa Rated output (with electric air reheater) 1730 W/7.5 A 1800 W/7.8 A 2250 W/9.8 A 2670 W/11.6 A Power connection 10 2.3 m power cord with 2.3 m power cord with 2 m power cord with plug 2 m power cord with plug plug to earthed outlet plug to earthed outlet to earthed outlet socket 1 to earthed outlet socket 1 socket 1 phase 230 V, 50 socket 1 phase 230 V, 50 phase 230 V, 50 Hz, 16 A phase 230 V, 50 Hz, 16 A Hz, 10 A Hz, 10 A Swegon reserves the right to alter specifications. Swegon CASA Quick Guide Premium control system Function Description User interface Settings and adjustments for the operation of the unit are made via a control panel with pushbuttons and a display. The desired language can be set. The control panel also features an LED that indicates different functions. If the Premium cooker hood is connected to the unit, the operating mode can be controlled from the cooker hood. Fan speed Five fan speeds for the supply air fan and extract air fan can be preset. The preset fan speeds are then chosen for the different operating modes. Operating mode Normally the following operating modes are used: Away = Low fan speed when no one is at home. At Home = Normal fan speed. Boost = High fan speed Additional operating modes can be used, e.g. for summer night cooling and in connection with demand regulation, e.g. with a humidity sensor. Timer 24-hour/weekly timer featuring four programs for automatic time control of the operating modes Away and Home. Operating modes can be changed manually from the control panel, or the cooker hood. Temperature control, winter mode If the capacity of the heat exchanger is not sufficient to reach the required supply air temperature the following occurs: The R-series and W-series with electric reheating: 1) The electric air heater is enabled when the supply air does not reach the temperature set on the control panel’s display. 2) R series: If the supply air still does not reach the desired temperature, the speed of the supply air fan is reduced. The W-series with water-borne reheating: 1) The required temperature for the supply air is reach through regulating the hot water flow in the unit’s water coil according to the manual setting on a thermostat valve. Temperature control, summer mode R series: The rotary heat exchanger stops automatically when there is no heating requirement. W series: A bypass damper is opened manually (W80 &100) or automatically (W130 & 230) when there is no heating requirement. The outdoor air or extract air is then led pass the heat exchanger. F ree cooling in the summer (Only R85 & R120) The summer night cooling function is enabled, if specific temperature conditions are met. The heat exchanger in the unit stops, any electric air heater is switched off and even the speed of the fans can increase. The cool outdoor air is then used to cool down the home. Cooling recovery (Only R85 & R120) In the summer if the indoor air is cooler than the outdoor air, the rotary heat exchanger starts and recovers the relative cooling from the property’s extract air. Negative pressure compensation If the Premium cooker hood is connected to the unit, the negative pressure is compensated when the cooker hood damper opens. Other cooker hoods or central vacuum cleaners require a separate differential pressure sensor in the extract air duct of the cooker hood/central vacuum cleaner, see the table over electronic accessories. Fireplace switch function The function can be selected and temporarily increases the speed of the supply air fan and lowers the speed of the extract air fan. The positive pressure that then forms in the property presses out the air through the chimney and prevents smoke from entering the room when the fire is lit. Operating mode display The current operating status is shown continuously with text on the control panel display and by different LED colours. Service reminder The reminder interval for service can be set from 3–12 months. Alarms In the event of operating disturbances an alarm is given through a flashing red LED and an error message in plain text on the control panel’s display. Overheating protection Automatic protection that stops motors and an electric air heater, if installed, in the event of a high temperature. Anti-frost protection R series: The speed of the supply air fan is lowered in the event of a risk of freezing in the heat exchanger. W series: The electric air heater is enabled to preheat input air and the speed of the supply air fan is lowered in the event of a risk of freezing in the heat exchanger. Communication Communication and remote control can take place via a Modbus gateway (accessory) where all control functions can be made available via Modbus RTU. Communication can also take place via external equipment through connection to the inputs and outputs on the unit’s DDC terminal block, which makes it possible to read the operating status and control the fans and temperature 0-10 Volt. Installation & Service Menu for settings and adjustment of the unit’s functions. Swegon reserves the right to alter specifications. 11 Swegon CASA Quick Guide Mechanical accessories Component R85 R120 W80 W100 W130 W230 Stainless steel: PR085B6R White: PR085B6V (included as standard, but can be ordered as a spare part) – – – – – 500 W Can be ordered factory fitted 800 W Can be ordered factory fitted Included as standard Included as standard Included as standard Included as standard Wall mounting bracket Included as standard Included as standard PW080SAT Included as standard – – Roof mounting frame Right: PR085RKA Left: PR085LKA 10212KA PW080KA PW100KA – – Cover plate for the front panel Electric air heater for reheating Floor base – – – – 10213J 10223J Water trap for the condensation water drain UVL UVL UVL UVL UVL UVL Mounting frame with vapour barrier PR085YP 10212YP PW080YP PW100YP 10213YP – Replacement filter, kit PR085FS 10212RSS PW080FS PW080FS 102W13SS 102W23SS Electronic accessories Component Application area Premium control panel Accessories for R85 and W80. In apartment buildings and terrace house developments and if R85/W80 are controlled from the cooker hood, it is sufficient with one control panel located in the building manager’s office in order to make settings and adjustments. One control panel is included as standard with other units, but if necessary extra control panels can be installed, for example, one on each floor in two-storey apartments. For recessed mounting. Can also be surface mounted with the mounting frame accessory (102PAK). A 20 m long modular cable is included. Differential pressure sensor 20-200 Pa for use in the extract air duct for central vacuum cleaner or cooker hoods that do not have indication of the unit’s function for negative pressure compensation. Also see the section about “Negative pressure compensation” in the description of standard control functions. The sensor detects a rise in humidity and automatically increases the fan speed. Suitable for areas such as saunas, bathrooms, utility rooms, etc. The sensor detects a rise in carbon dioxide content and automatically increases the fan speed. Suitable in areas where the number of occupants varies. Can be used with 0-10 Volt signal for two limit values and two increases in fan speed or with the relay function for one limit value and one increase in fan speed. The sensor detects movement and automatically increases the fan speed. Suitable for areas that are not used regularly. Timer for the control of operating times. Suitable if you do not wish to use the unit’s integrated time control. For recessed mounting. Sensor for optional placement that replaces the unit’s integrated extract air temperature sensor. Suitable if the unit’s integrated extract air temperature sensor does not provide representative values. Pushbutton that can be used as an extra fireplace switch. For recessed mounting. Manual pushbutton with a timer that raises the fan speed during the selected time (15, 30 min, 1, 2, 4, 8 hours). Suitable for areas such as saunas, bathrooms, utility rooms, etc. For recessed mounting. Gateway for communication and remote control of the unit via the Modbus protocol. Differential pressure sensor 117PK2 Humidity sensor 117KKH Carbon dioxide sensor 117HDL Presence detector 102LT Timer, digital 105A1 Room temperature sensor PRTG Extra fireplace switch 102TKC Pushbutton with timer 105TK Modbus Gateway P-MB Modular cable P-MK20 12 20 m modular cable with RJ9 connectors and a connector, which permits an extension, or a further modular cable (20 m long modular cable included as standard with the Premium control panel). Swegon reserves the right to alter specifications. Swegon CASA Quick Guide Cooker hoods Classic Design hoods Blues / Pop Salsa Tango Jazz Swing Rock Classic is a series of modern and efficient cooker hoods without fans with different mounting options. The grease filter is made of metal and cooker hoods have a dimmable LED lighting. All cooker hoods have Ø125 mm duct connections. The cooker hoods Blues and Jazz can be selected with SAFERA stove guard that shuts off the power to the stove if it has been left on. The stove guard also has a lock function that prevents unauthorized persons switching on the power to the stove. Versions • For use together with CASA ventilation units with Premium control technology: Blues, Salsa, Tango. • For use mounted directly under ventilation unit CASA R85: Jazz • For use together with CASA ventilation units with ILVA control technology: Blues, Salsa, Tango. • For use together with a central power roof ventilator: Blues/Pop, Salsa, Tango. Elegant and efficient stainless steel designer hoods without fan for installation against the wall or suspended above a kitchen island. The grease filter is made of metal and the designer hoods have halogen lighting. Available in 600 mm or 900 mm widths and can be connected with 125 mm or 160 mm ducts. The designer hoods can control 3 fan speeds on CASA ventilation units with Premium control technology. The designer hoods have a motor controlled damper with selectable opening time. Specific characteristics Blues For cabinet integration White or stainless steel. With 500 or 600 mm. With motor controlled damper and touch panel. Can be selected with SAFERA stove guard. Pop: For cabinet integration White. With 500 or 600 mm. Without damper and control, only lighting. Salsa: For cabinet integration Slide-in White or silver coloured With 500 or 600 mm. With motor controlled damper and touch panel. Tango: For recessed mounting. White. With extendible hood supplied with cabinet door that matches the kitchen cabinets. Equipped with gas cartridge for easy opening. With 500 or 600 mm. With motor controlled damper and touch panel. Jazz: Mounted directly under the ventilation unit CASA R85. White or stainless steel. Width 600 mm. With motor controlled damper and touch panel. Can be selected with SAFERA stove guard. Swegon reserves the right to alter specifications. 13 Swegon CASA Quick Guide Duct products Supply air diffuser DOMO Extract air diffuser EXC Sound attenuator CLA-A Penetration seal Product Rectangular supply air diffusers for wall or ceiling mounting. Circular extract air registers for wall or ceiling mounting. Effective sound attenuator with very small inset dimensions and low pressure drop. Penetration seal for ducts that creates a sealed penetration through the roof and vapour barrier. Material Bottom section of magnesium and front of ABS plastic. Interior components of PP plastic and galvanized sheet steel. Enamelled sheet steel Outer casing of galvanized sheet steel, environment class M2. Inside filled with mineral wool covered with self-supporting outer surface that is type approved regarding cleaning, fibre migration, age resistance and emissions. Plastic duct sleeves Cell rubber Colour White, RAL 9010 (correWhite, RAL 9010 (corresponds to NCS S0502-Y) sponds to NCS S0502-Y) Alternative colours available Alternative colours available at extra cost. at extra cost. Untreated Black Ductwork leakage class D. Type-approved fire-resistance class EI30. CLA-a-100-500: Ø100 mm, length 500, width 208, height 152 mm. Static integral attenuation 26 dB at 500 Hz. Max 90 l/s, pressure drop 8 Pa at 40 l/s. CLA-a-100-1000: Ø100 mm, length 1000, width 208, height 152 mm. Static integral attenuation 44 dB at 500 Hz. Max 90 l/s, pressure drop 8 Pa at 40 l/s. Larger sizes are available. Available in sets of 3. Design and capacity 14 Adjustable air distribution pattern Regulated flow. DOMO-b-100: Ø100 mm, 22 l/s at 30 db(A) and 30 Pa Regulated flow. EXC-a-100: Ø100 mm, 17 l/s at 30 db(A) and 100 Pa. EXC-a-125: Ø125 mm, 33 l/s at 30 db(A) and 100 Pa. Larger sizes are available. 102CLT10: For 100 mm duct 102CLT12: For 125 mm duct 102CLT16: For 160 mm duct Swegon reserves the right to alter specifications. Swegon CASA Swegon CASA is suitable for all types of residences Swegon reserves the right to alter specifications. 15 www.swegon.com EN-Swegon CASA overview. 11/01/2014