Preview only show first 10 pages with watermark. For full document please download

Hp Storageworks Msa2000 G2 Installation Instructions

   EMBED


Share

Transcript

Connecting remote management hosts One server connected to a MSA2000i G2 enclosure About this document The management host directly manages systems out-of-band over an Ethernet network. A: One server/single path requires one (1) Ethernet cable. This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes that you are qualified in the servicing and installation of computer equipment, and are trained in recognizing hazards in products and hazardous energy levels. For complete information on installing and configuring your MSA product, please see the user guide provided with your MSA2000 G2. The latest version of this guide can be downloaded at: http:// www.hp.com/support/manuals. 1. Connect an Ethernet cable to the Ethernet management port on each controller. 2. Connect the other end of each Ethernet cable to a network that your management host can access (preferably on the same subnet). HP StorageWorks MSA2000 G2 installation instructions This document contains installation and configuration for the following MSA2000 G2 models: MSA2000 G2 direct-connect configurations • MSA2000i G2 The MSA2000i G2 supports up to four direct connect server connections, two per controller. The MSA2000sa G2 supports up to eight direct connect server connections, four per controller. Connect cables from the servers' HBAs to the controller ports as shown in the following illustrations. For installation and configuration information specific to the MSA2000fc G2, see the HP StorageWorks MSA2312/2324fc installation instructions and the HP StorageWorks MSA2312/2324fc Configuration Poster. Any number or combination of LUNs can be shared among a maximum of 32 servers as long as the total adds up to no more than 511 LUNs per MSA2000sa G2 or 512 LUNs per MSA2000i G2. • MSA2000sa G2 Step 1: Install and secure equipment into the rack A + B: One server/dual path requires two (2) Ethernet cables. Two servers connected to a MSA2000i G2 enclosure Two servers/dual path requires four (4) Ethernet cables. One server connected to a MSA2000sa G2 enclosure A: One server/single path requires one (1) mini-SAS 4x cable. A + B: One server/dual path requires two (2) mini-SAS 4x cables. Use the rack installation poster provided with your MSA2000 G2 array enclosure to install the array into the rack. MSA2000sa G2 switch-connect configurations IMPORTANT: • Any number or combination of LUNs can be shared among a maximum of 32 servers as long as the total adds up to no more than 511 LUNs per MSA2000sa G2 or 512 LUNs per MSA2000i G2. Site requirements © Copyright 2009 Hewlett-Packard Development Company, L.P. Detailed site requirements are provided on the back of the rack installation poster and in the user guide located on the Software Support/Documentation CD. First edition: June 2009 The information in this document is subject to change without notice. Rack planning Printed in China For information about setting up the rack, including the appropriate warnings and cautions, refer to the documentation that came with your rack. Updated rack information can be downloaded at: http:// www.hp.com/products/racks. www.hp.com Two servers connected to a MSA2000sa G2 enclosure Two servers/dual path requires four (4) mini-SAS 4x cables. Step 3: Connect cables Common cable configurations are included here. For the complete list of supported cable/controller configurations, see the HP StorageWorks MSA2000 G2 cable configuration guide which can be downloaded at http://www.hp.com/support/manuals. *515941-002* • Dual density configurations support four 3Gb SAS BL Switches per blade enclosure. • Only use supported mini-SAS 4x cables with 3Gb connectors. Blade enclosures — blade servers/two 3Gb SAS BL switches Step 2: Install hardware options For information on installing hard drives and other options, see the installation instructions provided with your option or on the Software Support/Documentation CD. • Single density configurations support two 3Gb SAS BL Switches per blade enclosure. Cables required: four (4) mini-SAS 4x cables. Four servers connected to a MSA2000sa G2 enclosure Four servers/dual path requires eight (8) mini-SAS 4x cables. MSA2000 3.5” 12–drive I/O module MSA2000 G2 Controller MSA70 I/O module mini-SAS to SAS** mini-SAS to SAS* MSA2000 3.5” 12–drive I/O module SAS to SAS* * For these connections, 0.6m cables are recommended. ** For these connections, 0.5 cables are recommended. mini-SAS to SAS cables must be purchased separately. MSA2000 3.5" 12-drive enclosure cable options NOTE: The following figures show only the MSA2000sa G2 enclosure. Cabling configurations and requirements for connecting the MSA2000i G2 to MSA2000 3.5” 12–drive enclosures are identical. Additional drive enclosure cable requirements IMPORTANT: • When installing SAS cables, only use supported SAS 4x cables with 3Gb connectors. • SAS to SAS 0.6m cables are provided with the MSA2000 3.5" 12-drive enclosure (one per controller). MSA2000 G2 enclosure connected to three MSA70 drive enclosures Connecting a MSA2000 G2 array enclosure to three MSA70 drive enclosures requires six (6) mini-SAS to mini-SAS cables. MSA2000 G2 enclosure connected to one MSA2000 3.5” 12-drive enclosure A: Connecting a MSA2000 G2 single-controller array enclosure to a MSA2000 3.5” 12–drive enclosure with a single I/O module requires one (1) mini-SAS to SAS cable. A + B: Connecting a MSA2000 G2 dual-controller array enclosure to a MSA2000 3.5” 12–drive enclosure with dual I/O modules requires two (2) mini-SAS to SAS cables. • mini-SAS to mini-SAS 0.5m cables are provided with the MSA70 drive enclosure (one per controller). • The maximum length cable allowed in any configuration is 2m. • If additional or longer cables are required they must be purchased separately. See the MSA2000 G2 Quick Specs for details. MSA70 drive enclosure cable options • When expanding storage, a maximum of five (5) enclosures (including the array enclosure) OR ninety-nine (99) drives are allowed in the array. IMPORTANT: • The HP MSA70 drive enclosure requires firmware version 2.18 or later to be supported with the MSA2000 G2. • The following figures show only the MSA2000sa G2 array enclosure. Cabling configurations and requirements for connecting the MSA2000i G2 to MSA70 drive enclosures are identical. MSA2000 G2 cable requirements The following table provides SAS cable requirements for MSA controllers and drive enclosures connection combinations. MSA2000 G2 enclosure connected to one MSA70 drive enclosure Table 1 SAS cable requirements MSA2000 G2 Controller MSA70 I/O module MSA2000 3.5” 12–drive I/O module MSA2000 G2 Controller N/A mini-SAS to mini-SAS** mini-SAS to SAS** MSA70 I/O module mini-SAS to mini-SAS** mini-SAS to mini-SAS* mini-SAS to SAS* MSA2000 G2 enclosure connected to three MSA2000 3.5" 12-drive enclosures A: Connecting a MSA2000 G2 single-controller array enclosure to a MSA70 drive enclosure with a single I/O module requires one (1) mini-SAS to mini-SAS cable. Connecting a MSA2000 G2 array enclosure to three MSA2000 3.5" 12-drive enclosures requires two (2) mini-SAS to SAS cables and four (4) HP Ext. SAS cables. A + B: Connecting a MSA2000 G2 dual-controller array enclosure to a MSA70 drive enclosure with dual I/O modules requires two (2) mini-SAS to mini-SAS cables. Mixed drive enclosure cable options The following figure shows a MSA2000sa G2 array controller connected to a mixed configuration of MSA70 drive enclosures and MSA2000 3.5” 12–drive enclosures. This configuration requires seven (7) mini-SAS to SAS cables and one (1) mini-SAS to mini-SAS cable. Other mixed configurations might require different cables. Refer to “MSA2000 G2 cable requirements” on page 2 for more information. 3. Connect the primary power cords from the rack to separate external power sources. 4. Power on any attached MSA2000 3.5" 12-drive and MSA70 drive enclosures. 5. Power on the MSA2000 G2 array controller. 6. Power on servers (if they are powered down for maintenance purposes). To power on the system: 1. Press the power switches on the back of each drive enclosure to the On position. Wait several minutes to ensure that all drives can be recognized by the array controller. 2. Press the power switches on the back of the array controller enclosure to the On position. Step 5: Configure your MSA Refer to the user guide provided with your MSA2000 G2 for complete configuration and setup information. The latest version of the user guide is available at: http://www.hp.com/support/manuals. Additional resources HP product manuals: http://www.hp.com/support/manuals MSA products: http://www.hp.com/go/msa Storage products: http://www.hp.com/storage Servers: http://www.hp.com/go/servers SAN infrastructure: http://www.hp.com/go/san Ethernet NICs: http://www.hp.com/servers/networking Web Based Enterprise Services: http://h18023.www1.hp.com/support/ svctools/webes/index.html Step 4: Power on the components IMPORTANT: • Important safety information about power cords can be found on the Software Support/Documentation CD provided with your MSA chassis. To locate this information look for the Safety and Disposal guide located on the Documents tab. • Power on the enclosures and associated server(s) in the order documented below. 1. Verify that all power switches are off. 2. Using the provided AC power cords, connect each power supply module to one power source in the rack.