Transcript
QuickSpecs
HP StorageWorks MSL5000 SDLT Tape Library Family
Overview
HP StorageWorks MSL5000 SDLT Tape Library Family The HP StorageWorks MSL5026S2 and MSL5052S2 Tape Libraries provide a high performance mission critical automated midrange backup and restore solution using HP StorageWorks SDLT 320 GB tape drives in a compact 5U (MSL5026S2) or 10U (MSL5052S2) form factor, for direct-SCSI-attached and SAN environments. It provides unique investment protection with multi-unit scalability and a PCI backplane for future feature expansion. The MSL5000 SDLT Tape Library Family defines a new segment in the mid-range segment, with high availability features normally found on enterprise libraries.
HP StorageWorks MSL5052S2 Tape Library
HP StorageWorks MSL5026S2 Tape Library
What's New MSL5000 Tape Libraries now support SDLT 600 tape drives with drive upgrade kits.
DA - 11965
Worldwide — Version 7 — April 8, 2005
Page 1
QuickSpecs
HP StorageWorks MSL5000 SDLT Tape Library Family
Models HP StorageWorks NOTE: The HP StorageWorks MSL5052S2 Tape Library comes with 52 media slots (including two mail MSL5052S2 Tape Library slots) and up to four HP StorageWorks SDLT Tape Drives (number of drives determined by SKU chosen). Models MSL5052S2, 0 DRV, SDLT RM Library 255102-B21 NOTE: 0D1 will appear after this part number on your sales order if factory integration is indicated. MSL5052S2, 2 DRV, SDLT 320, RM Library 293474-B21 MSL5052S2, 2 DRV, SDLT 320, RM Library with embedded FC router option 293474-B24 NOTE: Each library installation will require, (1) library system, (1) geographically specific power cord, (1) SCSI cable for each SDLT 320 drive pair, and SDLT media with bar code labels for each MSL5052S2. Multiple configurations will require additional pass-through kits. NOTE: The minimum orderable configuration consists of a single library system (for instances where customer already has the necessary SCSI cables, power cord pair, and media). NOTE: Installation services may also be ordered for customers who want to have a certified HewlettPackard Engineer perform an onsite library installation.
HP StorageWorks NOTE: The HP StorageWorks MSL5026S2 Tape Library comes with 26 media slots (including one mail MSL5026S2 Tape Library slot) and one or two HP StorageWorks SDLT 320 Tape Drives (number of drives determined by SKU Models chosen). MSL5026S2, 0 DRV, RM Library 293472-B21 NOTE: 0D1 will appear after this part number on your sales order if factory integration is indicated. MSL5026S2, 1 DRV, SDLT 320, RM Library 293472-B22 MSL5026S2, 2 DRV, SDLT 320, RM Library 293472-B23 MSL5026S2, 1 DRV, SDLT 320, RM Library with embedded FC router option 293472-B24 MSL5026S2, 2 DRV, SDLT 320, RM Library with embedded FC router option 293472-B25 NOTE: Each library installation will require, (1) library system, (1) geographically specific power cord, (1) iSCSI cable for each SDLT drive pair, and up to 26 pieces of SDLT media with Bar Code Labels for each MSL5026S2. Multiple configurations will require additional pass-through kits. The minimum orderable configuration consists of a single library system (for instances where customer already has the necessary SCSI cables, power cord, and media). NOTE: Installation services may also be ordered for customers who want to have a certified HewlettPackard Engineer perform an on-site library installation.
DA - 11965
Worldwide — Version 7 — April 8, 2005
Page 2
QuickSpecs
HP StorageWorks MSL5000 SDLT Tape Library Family
Standard Features MSL5000 SDLT Tape Library Customer benefits
High availability feature for minimum downtime. Reliable, cost effective backup, restoration and archival solution that fits a growing companies storage needs. High storage capacity to backup large amounts of data in a small backup window. Easy to operate which equates to lower cost of ownership. Compressed form factor only taking 5U of rack space with a single module Removable magazines for off-site backup storage. Multi-unit scalability for future growth and investment protection. Compatible with a wide variety of operating systems, software applications, and server platforms.
Key Features
Dual redundant power supplies to provide higher level of availability and reliability are available on the MSL5052 models. Ultra2 LVD SCSI Interface. Two (MSL5026S2) or five (MSL5052S2) cPCI slots for added functionality through add-on cards in future. GUI based touch screen panel for easy library operation. Available as a rack-mount configuration. Multi-unit modular scalability, up to eight units, for future growth and investment protection. In addition, the MSL5052S2 can also scale with the MSL5026S2 library using the pass-through mechanism.
DA - 11965
Worldwide — Version 7 — April 8, 2005
Page 3
QuickSpecs
HP StorageWorks MSL5000 SDLT Tape Library Family
Product Highlights Multi-unit Modular Scalability
The HP StorageWorks MSL5026S2 Tape Library has the capability for multi-unit scalability; up to eight modules can be scaled together in a virtual library. The first two modules are linked using the MSL5000 universal pass-through mechanism, which has the elevator mechanism for tape movement. Additions of subsequent modules require the MSL5000 5U pass-through extender (one for each additional module). The MSL5052S2 also has the capability for multi-unit scalability - up to four modules can be scaled together in a virtual library. The first two modules are linked using pass-through mechanism, which has the elevator mechanism for tape movement and an MSL5000 10U pass-through extender. Additions of subsequent modules require additional MSL5000 10U pass-through extenders (one for each additional module).
Remote Management Interface
Web-based management is included to allow monitoring and managing the library from across the room or across the globe. Many of the functions that are available on the front panel are included in the remote management interface. These include, but are not limited to, library and drive status, moving media, load/unload tape drives, access to diagnostics, library configuration, library statistics, inventory check, and security settings.
HP StorageWorks Library The MSL5000 SDLT Tape Library Family configurations are supported on HP's industry-leading and Tape Tools (L&TT) diagnostic tool - HP StorageWorks Library and Tape Tools (L&TT). L&TT is a single, convenient program that's a snap to install and simple to operate. L&TT's intuitive user interface eliminates the need for training and deploys in less than five minutes. This robust diagnostic tool is designed for both the experienced professional and the untrained administrator. It ensures product integrity through selfdiagnostics and fast resolution to device concerns. Additional information on L&TT plus download information can be found at: http://www.hp.com/support/tapetools.
Manageability
The HP StorageWorks MSL5000 SDLT Tape Library Family configurations are fully supported through Insight Manager v7.0, providing information to administrators for robotic status, tape status changes and fault status. HP's TSMC (tape storage management console) software provides diagnostics and easy firmware upgrade capabilities.
Proven Reliability
Using SDLT tape drives, and proven library robotics with a rating of 2,000,000 robot load/unload cycles, the MSL5000 SDLT Tape Library Family provides the necessary high reliability for today's demanding environment.
Embedded Fibre to SCSI router Option
The MSL5000 SDLT Tape Library Family can optionally configure embedded Fibre to SCSI router for easy connection to a FC SAN, thus enabling direct Fibre connection to the library.
Investment Protection
The MSL5000 SDLT Tape Library Family can be upgraded to SDLT 600 or to Ultrium technology in 3 easy steps: 1. Remove the existing tape drives and replace them with the new tape drives 2. Upgrade the library firmware 3. Load the new media type into the library NOTE: When doing this, the library MUST be configured with one (1) drive per SCSI bus.
DA - 11965
Worldwide — Version 7 — April 8, 2005
Page 4
QuickSpecs
HP StorageWorks MSL5000 SDLT Tape Library Family
Product Highlights DLT/SDLT Technology
Digital Linear Tape uses a proven linear recording technology, a highly accurate tape guide system, and a read-after-write correction system to provide high-capacity and high reliability data backup and restore. DLT has fast become the industry-standard secondary storage tape format for departmental and enterprise backup. The new generations of SDLT tape drive, in addition to enhanced capacity and backup performance, provide several new features such as Laser Guided Magnetic Recording (LGMR) technology, Pivoting Optical Servo (POS), Magneto-Resistive Cluster Heads (MRC), Partial Response Maximum Likelihood (PRML) channel technology and backward read compatibility with earlier generations of DLT drives, to be able to read media written in DLT IV format.
Server Support
The HP StorageWorks MSL5000 SDLT Tape Library Family are supported on the following classes of HP systems: HP ProLiant servers HP UX Servers HP AlphaServers NOTE: For details of which models work with which systems, including third-party systems, visit http://www.hp.com/go/ebs for the latest hardware compatibility information.
Application Support
Automation and Network Utilities HP StorageWorks Library and Tape Tools v2.9 HP Tape Storage Management Console v2.3 (NT/2000) and 2.0 (NetWare) MRU (media robot utility) v1.4 HP Insight Manager v7.0
ISV/OS Support
For the most up-to-date ISV & OS support please consult the Enterprise Backup Solutions Compatibility Matrix at http://www.hp.com/go/ebs.
Media Partitioning Support
Media partitioning is the capability to create logical pools or partitions in a tape library. The MSL tape libraries media partitioning capability supports multiple drives types within a single library or in a multiunit stack. For current software supported, please consult the Enterprise Backup Solutions Compatibility Matrix at http://www.hp.com/go/ebs.
DA - 11965
Worldwide — Version 7 — April 8, 2005
Page 5
QuickSpecs
HP StorageWorks MSL5000 SDLT Tape Library Family
Service and Support, HP Care Pack, and Warranty Information Warranty
One-year warranty, one-year onsite next day service. Additional warranty protection can be purchased for all MSL5000 SDLT Tape Library Family products. NOTE: Certain restrictions and exclusions apply. Consult the Hewlett-Packard Customer Support Center for details.
Warranty Upgrade Options
Response - Upgrade on-site response from next business day to same day 4-hours Coverage - Extend hours of coverage from 5 days x 9 hours to 7 days x 24 hours Duration - Select duration of coverage for a minimum period of 1 year or multiple years
HP Care Pack Information HP Care Pack is defined as an upgrade to the product warranty attribute, available for a specific duration and hours of coverage. HP Care Pack is not available for less than the products warranty duration. HP Care Pack is available for sale anytime during the warranty period for most products, but the commencement date will be the same as the warranty start date (delivery date to end user customer). Proof of purchase may be required. HP Care Pack services are prepaid. For additional HP Care Pack (hardware & software) information, as well as orderable part numbers, please refer to the URL listed below: http://h18005.www1.hp.com/services/carepaq/index.html
Software Product Services Standalone telephone support Rights to new license version Media and documentation updates
Hardware Product Services
Installation services On-site maintenance (includes warranty support) Response time upgrades during the warranty period Post-warranty coverage For additional hardware installation and maintenance information please refer to the URLs listed below: http://h18005.www1.hp.com/services/carepaq/us/install/cp_storage.html http://h18005.www1.hp.com/services/carepaq/us/hardware/cp_storage.html
DA - 11965
Worldwide — Version 7 — April 8, 2005
Page 6
QuickSpecs
HP StorageWorks MSL5000 SDLT Tape Library Family
Service and Support, HP Care Pack, and Warranty Information HP Care Pack PS Information for EMEA
HP Care Pack Priority Services brings a totally new approach that removes the complexity from evaluating, planning and purchasing services on Hewlett-Packard Alpha and Storage platforms. HP Care Pack Priority Services are easy to purchase and easy to use and cover all external storage products not covered under server-based HP Care Pack services. Standard Offerings: HP Care Pack Priority Services provide an integrated hardware and software support that ensure consistent coverage across storage configurations. HP Care Pack Priority Service offers a rapid four-hour response with guaranteed work-through to completion for three years. HP Care Pack Priority Services have a standard call window of Monday to Friday 08:00 - 17:00 with uplifts to full 24x7 over three years with four-hour response time and work through to completion. HP Care Pack Priority Services also provide software support, with a two-hour response time for telephone access to highly trained support personnel. For more information on how to order HP Care Pack Priority Services in EMEA please contact you local Certified Integration Partner or Authorized Reseller. Customized Installation Services (including installation of vendor backup software) and contract based support services are available by contacting your local Services department.
Support Services
HP Services provides up to a three-year, limited warranty, fully supported by a worldwide network of resellers and service providers and 9x5 hardware technical phone support during the warranty period. In addition, available service offerings include a full range of optional packaged hardware and software services: Installation and start up Extended coverage hours and enhanced response times System management and performance services Availability and recovery services
Components
The following brick level options/components do not have individual HP Care Pack Services. These items will be included in product HP Care Pack Services into which they are installed. Tape Drives Power Supplies Cabling Adapters Fans
DA - 11965
Worldwide — Version 7 — April 8, 2005
Page 7
QuickSpecs
HP StorageWorks MSL5000 SDLT Tape Library Family
Kit Contents Model MSL5052S2 Library System
MSL5026S2 Library System
Description MSL5052S2, 0 DRV, SDLT 320, RM Library NOTE: 0D1 will appear after this part number on your sales order if factory integration is indicated. MSL5052S2, 2 DRV, SDLT 320, RM Library MSL5052S2, 2 DRV, SDLT 320, RM Library with embedded FC router option MSL5026S2, 0 DRV, SDLT RM Library NOTE: 0D1 will appear after this part number on your sales order if factory integration is indicated. MSL5026S2, 1 DRV, SDLT 320, RM Library MSL5026S2, 2 DRV, SDLT 320, RM Library MSL5026S2, 1 DRV, SDLT 320, RM Library with embedded FC router option MSL5026S2, 2 DRV, SDLT 320, RM Library with embedded FC router option MSL5026S2, 2 DRV, SDLT 320, TT Library Supplied with each Library Unit Library Unit (pre-configured with drives) Documentation Kit EFIJS Translation CD Users Guide Diagnostic diskette/Software Guide Warranty Card Safety Card Driver CD SCSI Terminators (1 per drive) SCSI Jumper Cable VHDCI Diagnostic Cable (for PC attach) Software: Tape Storage Management Console Media Robot Utility Mounting Slides for HP 9000/10000/11000 Rack (RM only)
DA - 11965
Worldwide — Version 7 — April 8, 2005
Part Number 255102-B21
293474-B21 293474-B24 293472-B21
293472-B22 293472-B23 293472-B24 293472-B25 293473-B22
Page 8
QuickSpecs
HP StorageWorks MSL5000 SDLT Tape Library Family
Related Options Upgrade Accessories
MSL5000 SDLT 320 upgrade drive NOTE: 0D1 will appear after this part number on your sales order if factory integration is indicated. MSL6000 SDLT 600 upgrade drive NOTE: The MSL6000 SDLT 600 upgrade drive can be used in either the MSL5000 or MSL6000 tape libraries. Please reference the Business Class Library Upgrade Matrix for complete upgrade requirements at: http://h18006.www1.hp.com/products/storageworks/tapecompatibility.html
293475-B21
Pass-through Mechanism MSL5000 Universal pass-through mechanism base unit Hardware NOTE: Includes elevator mechanism and router, required to connect first two units in a stack (capable of handling both SDLT and LTO media). MSL5000 10U pass-through extender NOTE: Supported by the MSL 10U Tape Libraries only. NOTE: Required one for each 10U unit connected to the stack, for third and additional units. MSL5000 5U pass-through extender NOTE: Supported by the MSL 5U Tape Libraries only. NOTE: Required one for each 5U unit connected to the stack, for third and additional units.
304825-B21
Rack-mounting Kits
MSL5000 system/e bracket Kit (HP racks) MSL5000 TT-RM KIT, ProLiant Rack MSL5000 TT-RM KIT, Alpha/HP Rack Alpha Rail Kit
304826-B21 231894-B22 231894-B21 254795-001
Power Cord
Power Cord, US/Canada/Mexico NOTE: Shipped with all units. Order Local power cords separately. Power Cord, (Australia/China/New Zealand) Power Cord, (South East Asia/India) Power Cord, (Central Europe) Power Cord, (United Kingdom/Hong Kong/Singapore) Power Cord, (Switzerland) Power Cord, (Italy) Power Cord, (Denmark) Power Cord, (Japan) NOTE: US/Canada/Mexico power cords are shipped with all models. Order geographically specific power cords as needed. (Unit requires 2 power cords - one for each power supply.)
227099-001
DA - 11965
Worldwide — Version 7 — April 8, 2005
AD589A
231824-B23
231824-B22
227098-011 157220-AR1 157215-021 157216-031 157219-111 157217-061 157218-081 139867-006
Page 9
QuickSpecs
HP StorageWorks MSL5000 SDLT Tape Library Family
Related Options WARNING: Use of a non-HP approved Power Cord may result in (1) use of a power cord that does not meet individual country specific safety requirements; (2) a power cord with insufficient conductor ampacity that could result in overheating with potential personal injury and/or property damage; and/or (3) an unapproved power cord could fracture resulting in the internal contacts being exposed which potentially cold subject the user to a shock hazard. Use ONLY an HP approved power cord for your particular country. HP disclaims all liability in the event a non-HP approved power cord is used.
SCSI Host Cables
Auto Power-On
SCSI Cable, VHDCI, 6 feet SCSI Cable, VHDCI/VHDCI, 12 feet SCSI Cable, VHDCI/Wide, 6 feet SCSI Cable, VHDCI/Wide, 12 feet
NOTE: NOTE Check the cable-adapter matrix for tape libraries on: ftp://ftp.compaq.com/pub/products/storageworks/tape-and-optical-storage/adapter-cable-matrix.pdf Auto Power-On for MSL5026 (Installation Band 5AU) HA124A1 Auto Power-On for MSL5052 (Installation Band 5AW) HA124A1 NOTE: The Auto Power-On feature allows the library to reboot in the event of a power failure without operator intervention; feature must be installed by an authorized service technician.
FC Host Bus Adapters
For more information on FC HBAs please consult the EBS connectivity matrix at http://www.hp.com/go/ebs
SCSI Host Bus Adapters
For more information on FC HBAs please consult the EBS connectivity matrix at http://www.hp.com/go/ebs
Interface Cards
Embedded FC Network Storage Routers to connect SCSI library to Fibre Channel hub/switch. Network Storage Router e1200-160 - Fibre Channel to SCSI Router NOTE: Configured in the Compact PCI (cPCI) slot within the MSL library.
Media
HP Care Pack Services
341174-B21 341175-B21 341176-B21 341177-B21
MSL5000 dual magazine pack DLT/SDLT NOTE: Two 13 slot magazines, left and right. HP SDLT 320 GB Data Cartridge HP SDLT 600 GB Data Cartridge HP SDLT Cleaning Cartridge HP SDLT Bar Code Labels NOTE: Option Kit ships with 24 data labels and 2 cleaning labels. Pre-labeled Media HP SDLT 220-320 pre-labeled data cartridge, 20 pack NOTE: This sku is only currently available in the US and through HP Direct Channels.
330728-B21
232136-B21 C7980A Q2020A C7982A Q2003A
C7980AL
NOTE: 'A' signifies a physical HP Care Pack; 'E" signifies an electronic HP Care Pack.
DA - 11965
Worldwide — Version 7 — April 8, 2005
Page 10
QuickSpecs
HP StorageWorks MSL5000 SDLT Tape Library Family
Related Options MSL5026S2 Fixed Care Packs Installation Installation (electronic) HW, 3-year, next-day, onsite HW, 3-year, next-day, onsite (electronic) HW, 3-year, next-day, 13x5, 4 hour response, onsite HW, 3-year, next-day, 13x5, 4 hour response, onsite (electronic) HW, 3-year, next-day, 24x7, 4 hour response, onsite HW, 3-year, next-day, 24x7, 4 hour response, onsite (electronic) HW, 3-year, next-day, 6 hour call to repair, onsite HW, 3-year, next-day, 6 hour call to repair, onsite (electronic) Band For Library MSL5026S2 Flexible Care Packs Initial Tape Library Installation 463 Initial Tape Library Implementation Into SAN 463 Subsequent Tape Drive Installation N/A HW, 3-year, next-day, on-site 463 HW, 3-year, 4-hour, 13 x 5, on-site 463 HW, 3-year, 4-hour, 24 x 7, on-site 463 Support plus, 3-year* 463 Support plus 24, 3-year* 463 MSL5052S2 Fixed Care Packs Installation Installation (electronic) HW, 3-year, next-day, onsite HW, 3-year, next-day, onsite (electronic) HW, 3-year, next-day, 13x5, 4 hour response, onsite HW, 3-year, next-day, 13x5, 4 hour response, onsite (electronic) HW, 3-year, next-day, 24x7, 4 hour response, onsite HW, 3-year, next-day, 24x7, 4 hour response, onsite (electronic) HW, 3-year, next-day, 6 hour call to repair, onsite HW, 3-year, next-day, 6 hour call to repair, onsite (electronic) Band For MSL5052S2 Flexible Care Packs Library Initial Tape Library Installation 464 Initial Tape Library Implementation Into SAN 464 Subsequent Tape Drive Installation N/A HW, 3-year, next-day, on-site 464 HW, 3-year, 4-hour, 13 x 5, on-site 464 HW, 3-year, 4-hour, 24 x 7, on-site 464 Support plus, 3-year* 464 Support plus 24, 3-year* 464
U4823A U4823E U2859A U2859E U2860A U2860E U2861A U2861E U9287A U9287E Installation Band 5DR 5DR 5DU N/A N/A N/A N/A N/A
HA113A1 HA114A1 HA113A1 HA101A3 HA103A3 HA104A3 HA109A3 HA110A3 U4824A U4824E U2862A U2862E U2863A U2863E U2864A U2864E U9288A U9288E
Installation Band 5DS 5DS 5DU N/A N/A N/A N/A N/A
HA113A1 HA114A1 HA113A1 HA101A3 HA103A3 HA104A3 HA109A3 HA110A3
* Support Plus covers Hardware support only. DA - 11965
Worldwide — Version 7 — April 8, 2005
Page 11
QuickSpecs
HP StorageWorks MSL5000 SDLT Tape Library Family
Related Options Hewlett Packard also offers 1-year options for the services quoted above. Due to the complexities involved with the initial installation of an enterprise Library into a SAN environment, Hewlett Packard recommends that customers take advantage of the SAN Implementation Service (HA114A1). This service covers pre-installation preparation activities, installation and configuration of the library and router, configuration of hosts and switches, verification testing and customer orientation. In order to maximize ROI and product uptime, and minimize the cost of ownership, Hewlett-Packard recommends the 3-year, 24 x 7 service options. These offerings will ensure that any product issue can be tackled when they occur (most back up issues will occur outside standard business hours) and that the service coverage regarding period, covers the minimum expected life of the host system.
DA - 11965
Worldwide — Version 7 — April 8, 2005
Page 12
QuickSpecs
HP StorageWorks MSL5000 SDLT Tape Library Family
Technical Specifications Dimensions Form Factor Out of box, 0 Drive, RM Out of box, 1 Drive, RM Out of box, 2 Drive, RM Shipping, 0 Drive, RM Shipping, 1 Drive, RM Shipping, 2 Drive, RM
Weight Out of box, 0 Drive, RM Out of box, 1 Drive, RM Out of box, 2 Drive, RM Shipping, 0 Drive, RM Shipping, 1 Drive, RM Shipping, 2 Drive, RM
MSL5026S2 Tape Library 5U Rack-mount 8.75 x 17.00 x 30.00 in (22.20 x 43.20 x 76.20 cm) 8.75 x 17.00 x 31.50 in (22.20 x 43.20 x 80.00 cm) 8.75 x 17.00 x 31.50 in (22.20 x 43.20 x 80.00 cm) 15.25 x 23.00 x 38.25 in (38.70 x 58.40 x 97.20 cm) 15.25 x 23.00 x 38.25 in (38.70 x 58.40 x 97.20 cm) 15.25 x 23.00 x 38.25 in (38.70 x 58.40 x 97.20 cm)
MSL5052S2 Tape Library 10U Rack-mount 17.50 x 17.00 x 30.00 in (44.50 x 43.20 x 76.20 cm) N/A
MSL5026S2 Tape Library 43.00 lb (19.5 kg) 52.00 lb (23.60 kg) 61.00 lb (27.70 kg) 75.00 lb (34.00 kg) 84.00 lb (38.10 kg) 93.00 lb (42.20 kg)
MSL5052S2 Tape Library 95.00 lb (43.10 kg) N/A 109.0 lb (49.40 kg) 147.00 lb (66.70 kg) N/A 161.00 lb (73.00 kg)
Control Panel
Library and Drive Status Move tape cartridges Load/Unload tape drives Maintenance (diagnostics) Library Configuration Statistics Inventory Check Security level set: operator, user, service Mail slot access Offline/Online Status Magazine removal/replacement
SCSI Interface Capacity(native) Capacity SDLT 320 (native) SDLT 600 (native)
Ultra2 LVD SCSI, VHDCI interconnect MSL5052S2 Tape Library MSL5026S2 Tape Library 4.16 TB 8.32 TB 7.8 GB 15.6 TB
DA - 11965
Worldwide — Version 7 — April 8, 2005
17.50 x 17.00 x 31.50 in (44.50 x 43.20 x 80.00 cm) 33.00 x 47.00 x 31.00 in (83.80 x 119.40 x 78.70 cm) N/A 33.00 x 47.00 x 31.00 in (83.80 x 119.40 x 78.70 cm)
Page 13
QuickSpecs
HP StorageWorks MSL5000 SDLT Tape Library Family
Technical Specifications SDLT 600 Performance (native)
MSL5026S2 Tape Library 36 MB/s per drive Supports 1 or 2 HP StorageWorks SDLT 600 Tape Drives for native transfer rates up to 259 GB/hr
MSL5052S2 Tape Library 36 MB/s per drive Supports up to 4 HP StorageWorks SDLT 600 GB drives for native transfer rates up to 518 GB/hr Supports up to 16 HP Supports up to 16 HP StorageWorks SDLT 600 Tape StorageWorks SDLT 600 GB Drives for native transfer rates up drives for native transfer rates up to 2.7 TB/hr (8 modules with to 2.7 TB/hour (4 modules with multi-unit scalability) multi-unit scalability)
Transfer Rate Base unit
Maximum configuration
SDLT 320 Performance (native)
MSL5026S2 Tape Library 16 MB/s per drive Supports 1 or 2 HP StorageWorks SDLT 320 Tape Drives for native transfer rates up to 115.2 GB/hr
SDLT 320 Transfer Rate Base unit
Maximum configuration
SDLT 600 Storage Capacity (compressed @ SDLT 600 Cartridge Capacity 2:1) SDLT 600 Transfer Rate Base Unit
Maximum configuration
SDLT 320 Storage Capacity (compressed @ Per Cartridge 2:1) Base Unit
Maximum configuration
Power Consumption Base unit Voltage Power Requirement (typical) Power requirement (maximum) Heat dissipation (typical)
DA - 11965
Supports up to 16 HP StorageWorks SDLT 320 Tape Drives for native transfer rates up to 921.6 GB/hr (8 modules with multi-unit scalability) MSL5026S2 Tape Library 600 GB per cartridge 36 MB/s per drive 26 slots (including one mail slot), for compressed (2:1) capacity up to 15.6 TB 208 slots, for compressed (2:1) capacity up to 124.8 TB (8 modules with multi-unit scalability) MSL5026S2 Tape Library 320 GB per cartridge 26 slots (including one mail slot), for compressed (2:1) capacity up to 8.32 TB Eight 26 slots, for compressed (2:1) capacity up to 66.56 TB (8 modules with multi-unit scalability)
MSL5052S2 Tape Library 16 MB/s per drive Supports up to 4 HP StorageWorks SDLT 320 GB drives for native transfer rates up to 230.4 GB/hr Supports up to 16 HP StorageWorks SDLT 320 GB drives for native transfer rates up to 921.6 GB/hour (4 modules with multi-unit scalability) MSL5052S2 Tape Library 600 GB per cartridge 36 MB/s per drive 52 slots (including two mail slots), for capacity of 31.2 TB (2:1 compressed) 208 slots, for capacity up to 124.8 TB (2:1 compressed) (4 modules with multi-unit scalability) MSL5052S2 Tape Library 320 GB per cartridge 52 slots (including two mail slots), for capacity of 16.64 TB (2:1 compressed) 208 slots, for capacity up to 66.56TB (2:1 compressed) (4 modules with multi-unit scalability)
MSL6030 Tape Library 90 to 140V AC @47 to 63 Hz 176 to 259V AC @47 to 63 Hz 180 Watts 200 Watts 612 BTU's/hour
MSL6060 Tape Library 90 to 132V AC @ 47 to 63Hz 180 to 264V AC @ 47 to 63Hz 300 Watts 360 Watts 1020 BTU's/hour
Worldwide — Version 7 — April 8, 2005
Page 14
QuickSpecs
HP StorageWorks MSL5000 SDLT Tape Library Family
Technical Specifications Acoustic Noise Robotics Performance
Reliability Environmental
Heat dissipation (maximum) Noise Power Emission Level Average sound pressure level Initialization time Inventory time Cartridge swap (drive to slot) MTBF MSBF Temperature range Humidity (wet bulb)
671 BTU's/hour 8 bels, maximum 52 dBA 100 sec 60 sec 15 sec average
1224 BTU's/hour 8 bels, maximum 52 dBA 240 sec 110 sec 22 sec average
250,000 hours (100% duty cycle) (excludes drives) 2,000,000 robot load/unload cycles Operating 50° to 95° F (10° to 35° C) Storage -40° to 140° F (-40° to 60° C) Operating 10 to 80% @ 82° F (28° C) Storage
10 to 90% @ 82° F (28° C)
Worldwide Product Safety Safety: IEC 60950 and EMC Approvals EMC: CISPR 22/class A, CISPR 24 For country specific compliance contact your local sales representative. Regulatory Model Number: ED1005 (One stack unit); ED1005A (Two stack unit)
© Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Windows NT is a US registered trademark of Microsoft Corporation. Unix is a registered trademark of The Open Group. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
DA - 11965
Worldwide — Version 7 — April 8, 2005
Page 15