Preview only show first 10 pages with watermark. For full document please download

Hp0 S11

   EMBED


Share

Transcript

http://www.TwPass.com HP0-S11 HP Integrating and Managing HP ProLiant ML/DL Servers in the Enterprise http://www.twpass.com/twpass.com/exam.aspx?eCode= HP0-S11 The HP0-S11 practice exam is written and formatted by Certified Senior IT Professionals working in today's prospering companies and data centers all over the world! The HP0-S11 Practice Test covers all the exam topics and objectives and will prepare you for success quickly and efficiently. The HP0-S11 exam is very challenging, but with our HP0-S11 questions and answers practice exam, you can feel confident in obtaining your success on the HP0-S11 exam on your FIRST TRY! HP HP0-S11 Exam Features - Detailed questions and answers for HP0-S11 exam - Try a demo before buying any HP exam - HP0-S11 questions and answers, updated regularly - Verified HP0-S11 answers by Experts and bear almost 100% accuracy - HP0-S11 tested and verified before publishing - HP0-S11 exam questions with exhibits - HP0-S11 same questions as real exam with multiple choice options Acquiring HP certifications are becoming a huge task in the field of I.T. More over these exams like HP0-S11 exam are now continuously updating and accepting this challenge is itself a task. This HP0-S11 test is an important part of HP certifications. We have the resources to prepare you for this. The HP0-S11 exam is essential and core part of HP certifications and once you clear the exam you will be able to solve the real life problems yourself.Want to take advantage of the Real HP0-S11 Test and save time and money while developing your skills to pass your HP HP0-S11 Exam? Let us help you climb that ladder of success and pass your HP0-S11 now! HP0-S11 QUESTION: 1 Which ProLiant Essentials product uses Virus Throttle to prevent the spread of viruses and worms? A. Intelligent Networking Pack B. Insight Control Linux Edition C. iLO Advanced Feature Pack D. Performance Management Pack Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=1 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 2 Your customer has an MSA30 set up in a single-bus configuration and wants to change it to a dual-bus configuration. How do you accomplish this? A. It is not possible to configure the MSA30 in a dual-bus configuration. B. You replace the single-port SCSI I/O module with a dual-port SCSI I/Omodul E. C. You set the Bus Configuration switch to dual-bus mode on the back of the MSA30 unit. D. You reconfigure the properties of the MSA30 controller using Array Configuration Utility (ACU). Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=2 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 3 You are performing capacity planning for an active/active cluster. Which factors are most important for you to consider? (Select two.) A. bandwidth of the cluster interconnect B. cluster node processor requirements C. memory requirements of each cluster node D. maximum number of concurrent user connections E. bandwidth between the cluster nodes and the shared storage Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=3 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 4 Click the Exhibit button. A customer requires your assistance in designing the database server shown in the attached exhibit. The database will have a large volume of writes to the log files and heavy read/write use of the data files. Which RAID configuration would provide the best performance? A. log files: RAID 5 data files: RAID 5 B. log files: RAID 5 data files: RAID 6 (ADG) C. log files: RAID 1+0 data files: RAID 5 D. log files: RAID 1+0 data files: RAID 6 (ADG) E. log files: RAID 6 (ADG) Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=4 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 5 You need to install an MSA50 enclosure in an HP rack but the enclosure unit is not available at the planned installation timE. Therefore, you need to allocate the required space in the rack and plan the installation once the enclosure is availablE. What is the EIA unit height of the MSA50 enclosure? A. 1U B. 2U C. 3U D. 4U Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=5 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 6 Which HP Systems Insight Manager task enables the administrator to gather information from a newly discovered network device? A. polling B. discovery C. identification D. data collection Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=6 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 7 Which software should be used to configure the write cache setting in the MSA1500cs? A. Array Diagnostic Utility B. Array Configuration Utility C. Resource Partition Manager D. Network Configuration Utility Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=7 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 8 A customer wants to order 20 ProLiant DL380 G5 Servers to be shipped to a field location with no IT support. The servers should be already racked, cabled, and have an operating system loaded when they are delivered to the field location. Which HP service is best suited for this situation? A. HP Factory Express B. HP Consulting Services C. HP Care Pack Installation Service D. HP Care Pack Next Business Day hardware support Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=8 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 9 Click the Exhibit button. Which systems are currently not monitored or licensed for performance monitoring using HP Systems Insight Manager? (Select two.) A. server sgh70413xa B. server sgh70413xb C. server sgh70413wy D. server home-ews3047277 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=9 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 10 You have a few ProLiant servers running Microsoft Windows Server 2003 that have the Emergency Management Services (EMS) enableD. Using the Special Administration Console (SAC), which command limits the memory usage of a process? A. k B. r C. m D. lock Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=10 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 11 Click the Exhibit button. From the screen shown, click the Array Configuration Utility (ACU). The ACU shows the Smart Array controller, but not the MSA1000 attached to the Linux server. The Linux server can access and use the LUNs on the MSA1000. What should you do to allow the ACU to configure the MSA1000? A. Install thehpacucli packag E. B. Install thecpqacuxe packag E. C. Install theProLiant Support Pack. D. Install theProLiant Integration Module Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=11 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 12 Which types of migration can be performed by HP Virtualization Management Software? (Select three. ) A. Virtual to Virtual migration B. Virtual to Physical migration C. Physical to Virtual migration D. ProLiant to Integrity migration E. Physical toProLiant migration Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=12 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 13 Which component license involves a communications protocol that provides direct transmission of data from the memory of one computer to the memory of another with minimal demands on the host CPU? A. AcceleratediSCSI Pack B. Virtual Connect Enterprise Manager C. InfiniBand Teaming Networking Pack D. RDMA Pack for Multifunction Gigabit Server Adapter Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=13 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 14 Which parameters have an effect on the amount of time required to perform an online capacity expansion? (Select two.) A. logical drive size B. amount of other I/O work the server is processing C. amount of physical memory installed in the system D. priority level of the rebuild operation set in the Array Configuration Utility (ACU) Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=14 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 15 Which processor currently uses 64-bit x86 based architecture and HyperTransport technology? A. AMDAthlon B. Intel Itanium2 C. AMDOpteron D. Intel Pentium IV Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=15 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 16 What is required to enable online spare memory on a ProLiant DL-series server? A. All processor sockets must be populated and the spare VRM must beinstalle D. B. All memory banks available in the server must be populated with DIMMs of the samesiz E. C. The DIMMs in the spare bank must be the same size or larger than those in the other banks. D. ProLiant Essentials must be installed on the system where online spare memory will be enableD. Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=16 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 17 Which advantage do AMD Opteron processors offer over Intel Pentium Xeon processors used in HP ProLiant servers? A. AMDOpteron processors use Burst Mode Memory technology. B. AMDOpteron-based memory is connected to each processor via a South Bridge chip. C. AMDOpteron-based system memory modules are controlled and managed by the processor they are attached to. D. AMDOpteron processors use the MemBus architecture that interconnects all installed processors and memory modules. Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=17 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 18 In a Fibre Channel fabric network, which network service is responsible for registering and maintaining a valid logical network address database that is used for LUN masking and zoning? A. Time Services B. CHAP Services C. Name Server Services D. Secured Fabric Services Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=18 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 19 Which address syntax is valid for iSCSI addressing? A. iqn.0202.hpstorag E. hp.com B. fqdn.2007.03.iSCSI.hp.com C. iqn.2006.02.com.hp:hpstorage D. iee E. iSCSI.ifqdn.2006.03.com.hp:hpstorage Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=19 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 20 Which technology in Ethernet switches ensures loop-free connectivity? A. Spanning Tree Protocol B. Spanning Topology Recovery C. Uplink Trunk Blocking Protocol D. Layer 2 Loop Broadcast Recovery Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=20 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 21 What is an example of a shared everything cluster model? A. HP IntegrityNonStop B. HPServiceguard for Linux C. Novell Netware Cluster Services D. Microsoft Windows 2003 Server Cluster Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=21 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 22 What is an example of a shared everything cluster model? A. Oracle RAC B. HP IntegrityNonStop C. Microsoft Windows 2003 Server Cluster D. HPServiceguard services on Linux Server Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=22 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 23 Which HP server uses HyperTransport architecture? A. BL20p B. DL140 C. DL385 D. ML370 E. rx2620 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=23 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 24 Which HP servers use HyperTransport architecture? (Select two.) A. BL480c B. ML150 C. DL365 D. ML570 E. DL320 F. DL585 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=24 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 25 By default with any addition pack installed, which file formats are available for reports generated from HP Systems Insight Manager? (Select threE. ) A. .txt B. .pdf C. .xml D. .prn E. .csv F. .html Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=25 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 26 Which type of task allows you to update software and firmware of several ProLiant Servers using HP Systems Insight Manager? A. Control B. Polling C. Distribution D. Management Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=26 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 27 After initial HP Systems Insight Manager v5.x discovery and type identification, a comprehensive data collection is attempted on all newly discovered devices. It will the store the details in the database on the Centralized Management Server (CMS). Which protocols are used in this comprehensive data collection? (Select threE. ) A. Cisco Discovery Protocol (CDP) B. Distributed Management Interface (DMI) C. Internet Group Management Protocol (IGMP) D. Web-Based Enterprise Management (WBEM) E. Simple Network Management Protocol (SNMP) Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=27 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 28 Which ProLiant Essentials product monitors and graphs the air temperature as it enters a server? A. HP Onboard Administrator B. HP Insight Power Manager C. HP Insight Control Linux Edition D. HPiLO Power Management Pack Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=28 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 29 A data center administrator wants to measure the BTU/hr generated by all the current ProLiant 380 G5 servers. The administrator wants to use this information to accommodate more servers without making changes to the data center cooling system. Which HP Essential product should the administrator use to accomplish this? A. HP Insight Power Manager B. HP Rack and Power Manager C. HP Insight Control Linux Edition D. HP Insight Control Environment forProLiant ML/DL E. HP Insight Control Environment for HPBladeSystem Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=29 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 30 Which ProLiant Essentials product erases the entire system during its installation process? A. HP Insight Control Environment B. HP Insight Control Linux Edition C. HP Virtual Machine Management Pack D. HP Insight Control Data Center Edition Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=30 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 31 Which file systems can be migrated using ProLiant Essentials Server Migration Pack - Physical to ProLiant? (Select two.) A. CIFS B. EXT3 C. NTFS D. VMFS E. FAT32 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=31 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 32 Which server subsystems can be managed using ProLiant Essentials Workload Management Pack? (Select two.) A. disks B. memory C. processors D. array controllers E. network adapters Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=32 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 33 Prior to performing a Virtual-to-Virtual (V2V) migration using ProLiant Essentials Virtualization Management Software, which licenses must be applied to the hosts involved? (Select two.) A. both virtual machine hosts must be licensed with VMM license B. both virtual machine hosts must be licensed with SMP license C. the source virtual machine host must be licensed with SMP license D. both the virtual machine and source hosts must be licensed with VMM, SMP and PMP license Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=33 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 34 You want to perform a Virtual-to-Virtual (V2V) migration using ProLiant Essentials Virtualization Management Software. Before performing this migration, which licenses must be applied to the hosts involved? (Select two.) A. The VMM license must be applied to both virtual machine hosts. B. The SMP license must be applied to both virtual machine hosts. C. The SMP license must be applied to the source virtual machine host. D. VMM, SMP and PMP licenses must be applied to both virtual machines and the source host. E. VMM, SMP and PMP licenses must be applied to the virtual machines, but not the source host. Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=34 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 35 Which packages are installed and used by default with the HP Rapid Deployment Pack Windows Edition 3? (Select two.) A. Kickstart B. MS-DOS 6.0 C. Microsoft Windows 98 D. LinuxPreinstallation Environment E. Microsoft Windows XP Professional F. Windows Preinstallation Environment Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=35 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 36 Which operating systems can be patched by HP Vulnerability and Patch Management Pack? (Select two.) A. Sun Solaris B. VMware ESX Server C. Novell NetWare Server D. Red Hat Enterprise Linux E. Microsoft Windows Server 2003 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=36 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 37 When using HP Vulnerability and Patch Management Pack integrated with HP SIM, which operating systems can be patched? (Select two.) A. HP-UX 11i v3 B. OpenVMS 8.3 C. Sun Solaris 9 D. VMware ESX Server 3.x E. Red Hat Enterprise Linux 9 F. Microsoft Windows Server 2003 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=37 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 38 What are software prerequisites for installing the HP ProLiant Essentials Virtual Machine Management Pack onto a Window-based Centralized Management Server (CMS)? (Select two.) A. OpenSSH B. SFTP client C. VMWare Virtual Infrastructure Client D. Windows Server 2003 Service Pack 2 E. Windows Management Instrumentation (WMI) Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=38 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 39 You are planning to use the HP Essentials Server Migration Pack to execute a V2V (Virtual-toVirtual) migration from one virtual machine host server to a new virtual machine host. HP SIM displays the following status icons in the VM column for each machine: Which action must be taken to allow the migration to proceed? A. install the VMM Agent on the target virtual machine host server B. install the VMM Agent on the source virtual machine host server C. apply the VMM Pack license to the target virtual machine host server D. apply the VMM Pack license to the source virtual machine host server Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=39 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 40 Which feature is exclusive to the HP Insight Diagnostics Offline Edition compared to the Online Edition? A. scheduling survey captures B. testing allProLiant Server subsystems C. printing multiple copies of the diagnostic results D. creating up to five hardware configuration snapshots Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=40 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 41 Which features are exclusive to the HP Insight Diagnostics Online Edition when compared to the Offline Edition? (Select threE. ) A. scheduling survey captures B. survey history and comparison C. testing allProLiant Server subsystems D. ability to view Integrated Management Logs (IMLs) E. creation of up to five hardware configuration snapshots Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=41 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 42 Which management solution enables the network administrator to deploy, manage, and monitor actual power utilization of HP ProLiant Servers in the data center? A. HP Insight Power Manager B. HP Insight Control Environment C. HP Insight Control Linux Edition D. HP Insight Control Data Center Edition Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=42 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 43 A network administrator wants to perform the following administrative tasks on HP ProLiant Servers in the data center: Deploy new servers Manage servers Monitor actual power utilization Which management solution enables the network administrator to accomplish this? A. HP Insight Power Manager B. HP Rapid Deployment Pack C. HP Insight Control Environment D. HP System Management Homepage E. HP Insight Control Data Center Edition Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=43 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 44 Which advanced feature of the iLO 2 should an administrator use to troubleshoot the root cause of faults, after a server has been restored to production service? A. mounting virtual media B. remote console sharing C. replay last boot or last fault sequence D. Active Directory integration for authentication Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=44 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 45 Which technology in the HP ProLiant Multifunction Gigabit Server Adapters requires per-port licensing? A. IP-based Storage (iSCSI) B. TCP/IP Offload Engine (TOE) C. Switch Assisted Load Balancing (SLB) D. Remote Direct Memory Access (RDMA) Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=45 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 46 Which statement is true about the HP StorageWorks MSA SAN Switch 2/8? A. It is mounted inside the MSA1000 enclosure I/O slot. B. It is only usable with MSA1000 and MSA1500cs storage solutions. C. It is not able to connect to other Brocade-series or Cisco-series Fabric switches. D. It has the Port-on-Demand feature, which enables port license activation whenneedeD. Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=46 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 47 The IT manager requests that you set up a server to attach to an external disk array that has the following features: a single shelf that only consumes 2U of rack space uses both SFF (Small Form Factor) SAS and SATA disk drives supports cascading to a second MSA for future expansion Which HP Modular Storage Array product meets these requirements? A. MSA20 B. MSA30 C. MSA50 D. MSA60 E. MSA70 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=47 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 48 What is required if you have two standalone Red Hat Enterprise Linux servers and a Microsoft Windows Server 2003 2-node cluster connected and sharing an active-active, dual-controller HP StorageWorks MSA1000? (Select two.) A. configure Arbitrated Loop Protocol on Linux servers HBAs B. use MPIO Full Features for MSA on both Windows 2003 servers C. use active-standby setting for all Red Hat Enterprise Linux server HBAs D. implement Selective Storage Presentation (SSP) for both Linux and Windows servers E. use HP Storage Mirroring on both Windows servers to replicate shared storage data to both servers local storage Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=48 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 49 Which type of clustering model is the Oracle Real Application Cluster (RAC)? A. shared-disk B. shared-nothing C. shared-memory D. shared-everything Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=49 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 50 A customer wants to implement a clustered database system in which all cluster nodes have simultaneous access to the data files. Which cluster model should the customer choose? A. shared disk B. shared nothing C. shared memory D. shared everything Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=50 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 51 Which HP clustering solution provides support for up to eight cluster nodes based on Windows Server 2003, StorageWorks Continuous Access Enterprise Virtual Array (EVA), and ProLiant ML/DL Servers? A. HPProLiant Cluster F200 B. HPProLiant Cluster F500 C. HP Cluster Platform 3000 D. HP Cluster Platform 4000 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=51 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 52 Your customer wants to implement a cluster solution that supports up to six cluster nodes. The customer wants it to run Microsoft Windows Server 2003 and use HP StorageWorks Continuous Access Enterprise Virtual Array (EVA) and ProLiant ML/DL Servers. Which cluster solution meets these requirements? A. HPProLiant Cluster F200 B. HPProLiant Cluster F500 C. HP Cluster Platform 3000 D. HP Cluster Platform 4000 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=52 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 53 Which HP clustering solution is correct for a customer designing a High-Performance Computing (HPC) environment consisting of AMD Opteron processor-based ProLiant Servers, Linux, and InfiniBand cluster interconnect? A. HPProLiant Cluster F200 B. HPProLiant Cluster F500 C. HP Cluster Platform 3000 D. HP Cluster Platform 4000 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=53 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 54 Your customer wants to implement a High-Performance Computing (HPC) environment consisting of AMD Opteron processor-based ProLiant Servers. The customer wants it to run a Linux OS and take advantage of the HP InfiniBand cluster interconnect. Which cluster solution meets these requirements? A. HPProLiant Cluster F200 B. HPProLiant Cluster F500 C. HP Cluster Platform 3000 D. HP Cluster Platform 4000 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=54 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 55 What does the Cluster Services for Microsoft Windows Server 2003 Enterprise Edition require? (Select two.) A. basic disks B. SecurePath C. dynamic disks D. NTFS partitions E. FAT32 partitions Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=55 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 56 You are performing a new installation of HP Rapid Deployment Pack Windows Edition 3. Where are the VMware ESX server installation files stored? A. on a separate NFS server in a virtual directory namedosdist B. in the MSDE or Microsoft SQL Server database named images C. on the deployment server in the ....\Altiris\eXpress\Deployment Server\images folder D. on the deployment server in the ....\Altiris\eXpress\Deployment Server\lib\osdist folder Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=56 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 57 You have completed the installation of HP Rapid Deployment Pack Windows Edition 3 onto your existing CMS server. Where are the Windows Server 2003 OS installation files stored? A. on a separate NFS server in a virtual directory namedosdist B. on the SAN in a folder named by the administrator at installation time C. on the deployment server in a folder named by the administrator at installation time D. on the deployment server in the ....\Altiris\eXpress\Deployment Server\images folder E. on the deployment server in the ....\Altiris\eXpress\Deployment Server\lib\osdist folder Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=57 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 58 Which component is no longer required by HP Rapid Deployment Pack Windows Edition 3.0 and later? A. ProLiant Integration Module B. dedicated MSDE or SQL Server database C. Rapid Deployment Pack SIM Integration Module D. separate NFS server for Linux scripted deployments Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=58 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 59 You have upgraded from HP Rapid Deployment Pack Windows Edition 2.x to 3.0. What is the major change introduced in RDP Windows Edition 3.0? A. ProLiant Integration Module is no longer require D. B. The MSDE or SQL Server database can beshare D. C. Linux scripted deployments no longer require a separate NFS server. D. The Rapid Deployment Pack SIM Integration Module is no longerrequireD. Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=59 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 60 You are planning for seven sets of two-node Microsoft Windows Server 2003 high-availability clusters using a single MSA1500 FC SAN disk array. What is the limiting factor in terms of scalability? A. inter-cluster heartbeat connection limitation B. storage capacity for the cluster quorum disks C. concurrent failover capabilities of the seven sets of clusters D. maximum logical drives supported on the MSA1500 controllers Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=60 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 61 Which storage component is required to support the 2km radius between the nodes and the shared storage of an HP Serviceguard for Linux cluster? A. HPStorageWorks MSA1510i B. HPStorageWorks MSA1500 C. HPStorageWorks Business Copy EVA D. HPStorageWorks Continuous Access EVA Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=61 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 62 What is the most important consideration when performing capacity planning for an active/active cluster? A. bandwidth of the public network B. bandwidth of the cluster interconnect C. maximum number of concurrent user connections D. processor and memory requirements of each cluster node E. bandwidth between the cluster nodes and the shared storage Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=62 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 63 What is required for the cluster interconnect by Microsoft Cluster Server? A. SNMP B. DCOM C. TCP/IP D. NetBEUI E. MSDTC Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=63 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 64 Which protocol is used by Microsoft Cluster Services (MSCS) for proper cluster heartbeat communication? A. SMTP B. SNMP C. DCOM D. TCP/IP E. MSDTC Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=64 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 65 Which HP clustering solution provides support for Quadrics interconnects? A. HPProLiant Cluster F200 B. HPProLiant Cluster F500 C. HP Cluster Platform 3000 D. HP Cluster Platform 4000 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=65 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 66 Your customer is considering implementing one of the following HP cluster offerings: HP ProLiant Cluster F200 HP ProLiant Cluster F500 HP Cluster Platform 3000 HP Cluster Platform 4000 Which unique feature does the HP Cluster Platform 4000 offer? A. Myrinet interconnect support B. Quadrics interconnect support C. InfiniBand interconnect support D. ProLiant servers using Intel Xeon CPUs E. ProLiant servers using AMD Opteron CPUs Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=66 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 67 With which ProLiant Essentials product must you exercise caution, as it can erase the entire system during its installation process? A. HP Insight Power Manager B. HP Insight Control Environment C. HP Insight Control Linux Edition D. HP Insight Control Data Center Edition Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=67 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 68 A customer wants to use the Deployment Server Web Console of RDP Windows Edition 3.x to deploy Red Hat and SuSE Linux. Which component is required for the Web Console to function properly? A. File Transfer Protocol (FTP) service B. Apache Tomcat Service for Windows C. Internet Information Server (IIS) with ASP.NET D. Dynamic Host Configuration Protocol (DHCP) service Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=68 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 69 Which component is required for the Altiris Deployment Server Web Console to properly deploy Red Hat and SuSE Linux? A. File Transfer Protocol (FTP) service B. Apache Tomcat Service for Windows C. Internet Information Server (IIS) with ASP.NET D. Dynamic Host Configuration Protocol (DHCP) service Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=69 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 70 Where does HP Rapid Deployment Pack Windows Edition 3.x store Linux installation files for scripted deployments? A. on a separate NFS server B. in the MSDE or SQL Server database C. on the deployment server in the SYSPREP share D. on the deployment server in the DSLIB virtual directory. Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=70 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 71 Where on the deployment server does HP Rapid Deployment Pack Windows Edition 3.7 store Linux installation files for scripted deployments? A. on a network share B. on the PXE server C. in the SYSPREP share D. in the DSLIB virtual directory E. in the DEPLOY virtual directory Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=71 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 72 When installing HP Rapid Deployment Pack Windows Edition 3.7, which component is automatically installed if an existing SQL database is not available, either remotely or locally? A. MSDE 2000 B. MSDE 2005 C. SQL Server 2005 Express D. SQL Server 2005 Standard E. Oracle 10g Windows Edition Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=72 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 73 When designing an active/active cluster, what should you consider when planning for cluster failover? A. capacity of shared storage B. data integrity between both nodes C. data transfer speed of shared storage D. heartbeat communications speed between nodes E. failover resource requirements on the surviving node Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=73 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 74 What is a key feature of Instant Support Enterprise Edition (ISEE)? A. management of patches and software updates B. ability to search technical knowledge databases C. provide 4-hour response to critical support calls D. continual monitoring of a heterogeneous data center Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=74 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 75 Click the Exhibit button. You are designing an HP RDP WE 3.x environment (as shown in the exhibit). The customer will use server images for all new server installations. Which component must have adequate disk storage to hold all these operating system images? A. FTP Server B. DHCP Server C. Database Server D. Deployment Server Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=75 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 76 A customer wants to expand the shared storage for the Microsoft Windows Cluster Servers online without having to use diskpart or convert the shared storage to a dynamic disk. Which HP software enables you to design such a solution? A. Storage Mirroring B. Business Copy EVA C. Storage Volume Growth D. Continuous Access EVA Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=76 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 77 You have a Microsoft Windows Server 2003 Enterprise two-node cluster with shared storage volumes. Two of the volumes consistently run out of free space on the disk, requiring periodic clean up. Which HP software can you use to expand the shared storage for the Cluster Servers online without having to use diskpart or convert the shared storage to a dynamic disk? A. Storage Mirroring B. Storage Expander C. Business Copy EVA D. Storage Volume Growth E. Continuous Access EVA Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=77 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 78 Click the Exhibit button. Which RAID configuration provides best performance for a customer designing a database server with a large volume of writes to the log files and heavy read/write use of the data files? A. log files: RAID 5; data files: RAID 5 B. log files: RAID 1+0; data files: RAID 5 C. log files: RAID 1+0; data files: RAID 6 (ADG) D. log files: RAID 6 (ADG); data files: RAID 6 (ADG) Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=78 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 79 Which Array Accelerator configuration provides best performance for a customer who needs a high-performance database server with heavy random reads and writes across data files? A. disabled B. 100% read caching C. 100% write caching D. 50% read and 50% write caching Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=79 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 80 You are estimating the number of disk drives to recommend to a customer for a database server. The customer collected and provided the following parameters. The disk subsystem must handle 1000 logical I/O requests per seconD. The ratio of logical reads to writes is 4:1. The number of physical I/O requests per second, per disk cannot exceed 100. All data files must reside on RAID 5 volumes. What is the least number of disk drives for the data files that satisfies the customer s performance requirement? A. 10 B. 12 C. 16 D. 24 E. 36 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=80 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 81 Your customer requires a disk subsystem that can handle 1000 logical I/O requests per seconD. Each disk must not perform more than 100 physical I/Os per seconD. The ratio of logical reads to writes is 4:1 and all data files must reside on RAID 5 volumes. In order to meet these performance requirements, what is the fewest number of disk drives that can be used for the data files? A. 12 B. 16 C. 20 D. 22 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=81 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 82 You are designing a disaster recovery scenario for a remote branch office using HP Storage Mirroring. You want a point-in-time identical copy of the source server s data captured to a central facility that will provide centralized DR in addition to the local tape backup solution at the branch officE. This backup process will be resynchronized at weekly intervals to minimize the impact on limited bandwidth from the branch office. Which operation within HP Storage Mirroring should you configure? A. mirroring B. replication C. restoration D. failure monitoring and fail-over Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=82 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 83 You are designing a disaster recovery plan for a remote branch office using HP Storage Mirroring. You want the source server s data captured to a central facility from the branch office as data on the source server changes. Which operation within HP Storage Mirroring should you configure? A. mirroring B. replication C. restoration D. failure monitoring and fail-over Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=83 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 84 You are designing a high-availability cluster and need the ability to replicate data to an off-site disaster recovery location in near real-timE. The solution must be implemented over existing WAN as there is no budget for installing expensive Fiber Channel infrastructurE. Which component allows remote data replication across TCP/IP networking? A. HP Virtual Replicator B. HP Storage Mirroring C. HP Cluster Replication D. HP Storage Volume Growth Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=84 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 85 What is the maximum cooling capacity of the HP Modular Cooling System? A. 5kW B. 10kW C. 20kW D. 30kW E. 40kW Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=85 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 86 You are installing multiple DL585 servers into the HP Modular Cooling System (MCS). How much power workload can the MCS handle? A. 20kW-25kW B. 30kW-35kW C. 60kW-70kW D. 70kW - 80kW Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=86 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 87 Which data center design services are offered by HP? (Select two.) A. analysis of financial affairs B. analysis of layout and placement C. analysis of performance management D. analysis of heating and cooling sources Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=87 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 88 A customer is designing a new data center. Which type of analysis should be included in the design? (Select two.) A. financial B. rack layout and placement C. heating and cooling sources D. system performance management Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=88 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 89 Which controller is required to connect an HP ProLiant DL380 G5 Server to an HP StorageWorks 70 Modular Smart Array (MSA) enclosure? A. Smart Array 642 B. Smart Array 6404 C. Smart Array E200 D. Smart Array P800 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=89 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 90 You are installing an external MSA70 direct-attached storage enclosure to expand the storage on a ProLiant DL385 server. Which Smart Array controller can you use? A. Smart Array 642 B. Smart Array 6404 C. Smart Array P800 D. Smart Array E200 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=90 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 91 How many 3.5" Universal hot-pluggable SAS or SATA drives can be installed in an HP StorageWorks 60 Modular Smart Array enclosure? A. 10 B. 12 C. 14 D. 25 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=91 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 92 Which configuration in an HP StorageWorks 1500cs Modular Smart Array solution has the largest number of physical disk drives installed? A. 8 units of MSA20 B. 4 units of MSA30 C. 8 units of MSA70 D. 4 units of MSA50 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=92 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 93 You are installing HP StorageWorks MSA1500cs SAN for a ProLiant clustering solution. How many units of external disk storage enclosure can be connected to the MSA1500cs? A. 8 units of MSA20 B. 4 units of MSA30 C. 6 units of MSA60 D. 4 units of MSA70 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=93 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 94 What is the EIA unit height of an HP StorageWorks Modular Smart Array 50 enclosure? A. 1U B. 2U C. 3U D. 4U Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=94 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 95 Which hardware support services are offered by HP Care Packs? (Select two.) A. 2nd-Day Service B. Pick-up and Return C. Next Day Exchange D. 2-Hour Call-to-Repair E. 6-Hour Call-to-Repair Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=95 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 96 When using Array Configuration Utility (ACU) to secure logical drives in an MSA1500cs, what allows you to mask the logical drive (LUN) to a specific server WWN? A. Secure Manager B. Host Presentation C. Storage Presenter D. Selective Storage Presentation Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=96 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 97 You are troubleshooting a ProLiant Server problem. The ProLiant Server is unable to PXE boot into HP Rapid Deployment (RDP) to deploy a new operating system from the HP RDP consolE. Which task enables you to configure the server so that it can be deployed using HP RDP? A. Reset the server PXE NIC using RBSU. B. Reset the systemiLO 2 using the HP SmartStart C D. C. Reset theiLO 2 and Smart Array controller using the HP SmartStart C D. D. Reset the system using RBSU Advanced Option - Erase NVRAM and disk. Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=97 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 98 You are redeploying an existing ProLiant DL server using HP Insight Control Environment for ProLiant ML\DL. The server is not able to boot to PXE and execute the deployment scripts from the Rapid Deployment Server (RDP). From the iLO 2 remote access, what do you do to resolve this problem? A. reset the systemiLO 2 using the HP SmartStart for ProLiant CD B. reset the system using RBSU Advanced Option - Erase system NVRAM and disk C. reset the server using the Erase System utility from HPSmartStart for ProLiant CD D. reset theiLO 2 and Smart Array controller using the HP SmartStart for ProLiant CD Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=98 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 99 When you activate iLO 2 with the Advanced License, you enable a new feature that helps the system administrator to troubleshoot and maintain records of tasks executed on the server consolE. This feature is introduced with iLO 2 firmware 1.30 or newer. What is this feature? A. iLO 2 Console Replay B. iLO 2 MP4 Capture & Player C. iLO 2 Console WMA Recorder D. iLO 2 Advanced Console Mode Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=99 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 100 Which ProLiant solutions can deploy operating systems, server applications, and operating system patches? (Select two.) A. HPSmartStart CD B. HP Insight Control Linux Edition C. HP Rapid Deployment Pack Windows Edition 3.x D. HP Server Migration Pack - Physical toProLiant (P2P) Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=100 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 101 Which ProLiant software solution is capable of scripting the deployment of new operating systems and patches to hundreds of units of ProLiant ML\DL servers in a network environment? A. HPSmartStart for ProLiant ML\DL B. HP Rapid Deployment Pack (RDP) C. HP Systems Insight Manager (HP SIM) D. HP Server Migration Pack - Physical toProLiant (P2P) Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=101 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 102 Which components make up the HP Rapid Deployment Pack Windows Edition 3.x solution? (Select threE. ) A. Altiris Deployment Server B. HP Systems Insight Manager C. HP Integrity Integration Module D. HPProLiant Integration Module E. HP Virtualization Management Software Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=102 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 103 Which components are selected and installed when executing HP Rapid Deployment Pack setup? (Select threE. ) A. Altiris Deployment Server B. HP Integrity Integration Module C. HPProLiant Integration Module D. HP Server Migration Pack - Universal Edition E. HP Insight Control Environment forProLiant ML\DL Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=103 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 104 What is the disk space requirement on the deployment server if you set up the deployment environment to deploy Microsoft Windows Server 2003 Enterprise Edition, Red Hat Enterprise Linux, SuSE Linux Enterprise Server and VMware ESX? A. 2GB B. 4GB C. 5GB D. 6GB Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=104 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 105 In the HP Rapid Deployment Pack Windows Edition, the Array Configuration Replicator (ACR) utility captures the array configuration of a reference server. Which settings can you modify in the captured configuration file? (Select four.) A. stripe size B. rebuild priority C. RAID set name D. logical partitions E. logical drive size F. read/write cache Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=105 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 106 Using HP Rapid Deployment Pack, you can use the Array Configuration Utility (hpacubin) to read the array configuration from an existing server. In the captured configuration file (plcapturE. ini), you can modify the stripe size and logical drive sizE. Which other settings can be modified in the captured configuration file (pl-capturE. ini)? (Select two.) A. rebuild priority B. RAID set name C. logical partitions D. read/write cache Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=106 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 107 Which utility is used by HP Rapid Deployment Pack Windows Edition to generate the array configuration file? A. ACUREP B. CONREP C. Array Configuration Utility D. Array Configuration Replicator Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=107 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 108 When using HP Rapid Deployment Pack version 3.5 or newer, which type of network services are required to deploy a Linux-based operating system? A. FTP services B. NFS services C. iSCSI services D. SAMBA services Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=108 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 109 HP Systems Insight Manager is unable to communicate and monitor a newly deployed HP ProLiant Server. The server was detected as an unknown devicE. Which component might be missing? A. HP Version Control Agent B. HPProLiant Support Pack C. HPProLiant Integration Module D. HP System Management Homepage Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=109 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 110 A customer has just successfully deployed a ProLiant DL380 server using Microsoft Windows Server 2003 CD mediA. When the customer tries to include the server in HP Systems Insight Manager - Remote Support Pack management, the server is detected as an unknown devicE. Which component might be missing? A. HP Instant Support Agent B. HP Version Control Agent C. HPProLiant Support Pack D. HP Remote Support Pack Agent Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=110 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 111 In HP Systems Insight Manager, which task enables the administrator to gather information from a newly discovered network device? A. query B. polling C. discovery D. identification E. data collection Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=111 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 112 Which tasks can be performed against groups of managed systems or events in HP Systems Insight Manager? (Select threE. ) A. reset task B. polling task C. control task D. inventory task E. discovery task F. notification task Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=112 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 113 Which software component within HP Insight Control Environment for ProLiant ML\DL is responsible for software management and update, contract and warranty management and escalating support tickets to the HP Support Center? A. Insight Power Manager B. iLO Power Management Pack C. Virtualization Management Suite D. Service Essentials Remote Support Pack Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=113 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 114 How does HP Systems Insight Manager gather details about a newly discovered network device? A. uses SSH and HTTPS methods to query and identify the new target features B. uses WBEM/SNMP to query the newly discovered device for more information C. uses polling methods to detect how a new device responds and to obtain information about the response TCP port D. uses the HP SIM built-in TCP port scanner to scan for active ports on the new device and list the services available Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=114 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 115 Which combinations form the data scalability cluster? (Select two.) A. SCO UNIX + Sybase B. Microsoft Windows + SQL C. Microsoft Windows + Oracle D. Microsoft Windows + Sybase E. Oracle Enterprise Linux + Oracle Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=115 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 116 What forms a data scalability cluster solution? (Select two.) A. IBM DB2 B. PostgreSQL C. Oracle RAC database D. Microsoft SQL Server 2005 E. Microsoft Windows Server 2003 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=116 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 117 Which components are necessary to build the HP Cluster Platform 3000/4000 architecture? (Select three. ) A. server nodes B. wireless router C. memory channel D. cluster software E. network connectivity F. wireless network address translator ANSWER: ADE wireless network address translator ANSWER: ADE Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=117 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 118 A customer wants to build and use a high performance technical computing platform. In reviewing the solutions available from HP, the customer expresses an interest in the HP Cluster Platform 3000. What are the basic components needed to build this architecture? (Select four.) A. wireless network address translator ANSWER: ADE wireless network address translator ANSWER: ADE B. virtualization nodes for high performance 3D graphics C. network connectivity such asInfiniBand or Gigabit Ethernet D. compute nodes such asProLiant DL140 or DL145 servers E. direct processor access bus network using HP Virtual Connect Ethernet solution F. direct memory access bus network (as remote storage) using HP Virtual ConnectFibre Channel Solution G. cluster management software such as XC System Software and HP Message Passing Interface (HP-MPI) Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=118 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 119 What are examples of HP Care Pack service offerings? (Select two.) A. HP One Time Replacement B. HP Gold level hardware support C. HP 2 Business Day parts exchange D. HP Mission Critical 3-hour response E. HP Mission Critical - proactive support Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=119 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 120 Which network services are required when setting up a 2-node Microsoft Windows Server Cluster? (Select two.) A. Microsoft Windows DHCP service B. Microsoft Windows Operation Center C. Microsoft Windows Server DNS service D. Microsoft Windows Computer Browser service E. Microsoft Windows Active Directory Domain Controller Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=120 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 121 Which type of configuration is required when setting up a two-node Microsoft Windows Server Cluster using the Quorum Disk model? (Select two.) A. InfiniBand heartbeat Link B. Microsoft Windows WINS service C. Microsoft Windows Computer Browser service D. shared storage on SCSI orFibre Channel adapter E. inter-cluster heartbeat Network Interface Card (NIC) Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=121 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 122 Which utility monitors and logs a logical processor s performance on a Windows Server 2003 System? A. Performance Monitor (perfmon.exe) B. Windows Task Manager (taskmgr.exe) C. Compute Configuration Utility (ccu.exe) D. Processor Configuration Utility (pcu.exe) E. Virtualization Management Software (vms.com) Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=122 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 123 Which tool provides processor utilization information on a Linux operating system? A. iostat B. vmstat C. monitor D. topmon E. perfmon Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=123 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 124 Where can you find processor utilization information on a ProLiant server running SUSE Linux Enterprise Server 10? A. iostat B. vmstat C. monitor D. topmon E. cpustat Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=124 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 125 Which software component can configure the Battery Backed Write Cache (BBWC) setting of a RAID 5 array set in the HP StorageWorks Modular Storage Array 1500? A. CommandView SDM B. Array Diagnostic Utility C. Array Configuration Utility D. Performance Management Pack E. Insight Control Data Center Edition Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=125 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 126 What is the minimum charge for a Modular Smart Array 1000 controller to reactivate the Array Accelerator after the battery was discharged? A. 80% B. 85% C. 90% D. 95% Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=126 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 127 The SAN storage performance of your ProLiant server to MSA1500cs is degrading. After reviewing the status using the appropriate utility, you notice the cache battery in the MSA1500cs was discharged and array acceleration was disable. What is the minimum charge level required to reactivate the Array Accelerator? A. 80% B. 85% C. 90% D. 95% Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=127 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 128 Which configuration benefits most from using HP ProLiant Multifunction Gigabit Server Adapters? A. HPProLiant Server connecting to EVA3000 storage array B. HPProLiant Server connecting to MSA1500i storage array C. HPProLiant Server connecting to ESA12000 storage array D. HPProLiant Server connecting to MSA1500cs storage array Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=128 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 129 Which storage connectivity configuration benefits most from using HP ProLiant Multifunction Gigabit Server Adapters? A. MSA70 storage array connectivity B. MSA1000 storage array connectivity C. MSA1510i storage array connectivity D. MSA1500cs storage array connectivity Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=129 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 130 Which ProLiant Essentials Value Packs allow you to monitor and manage the performance of Microsoft Virtual Server 2005 and VMware Infrastructure in the data center? (Select two.) A. Rapid Deployment Pack B. Intelligent Networking Pack C. Workload Management Pack D. Performance Management Pack E. Virtualization Management Software Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=130 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 131 Which HP Essentials software enables status and performance monitoring of ProLiant servers hosting virtual machines? (Select two.) A. Rapid Deployment Pack B. Performance Management Pack C. Virtual Center Management Server D. Virtualization Management Software E. Server Migration Pack - Universal Edition Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=131 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 132 Which option enables a customer to increase the performance of a Windows-based, multithreaded application on an HP ProLiant Server with minimum incremental cost? A. Install additional physical memory. B. Use TCP/IP Offload Engine adapter. C. Enable memory interleaving support. D. EnableHyperThreading in the system. E. Install a newer generation second processor. Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=132 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 133 What can a customer do to increase the performance of a Windows-based, multithreaded application on an HP ProLiant Server with minimal cost? A. use Mirrored Memory configuration B. upgrade to high speed DIMM modules C. enableHyperThreading in the system D. upgrade the system front side bus (FSB) Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=133 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 134 How many concurrent threads can a fully populated, dual-socket, single-core, HP ProLiant DL Server execute with HyperThreading enabled? A. 1 B. 2 C. 4 D. 8 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=134 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 135 How many concurrent threads can a fully populated, dual-socket, quad-core, HP ProLiant DL 380 G5 Server execute with HyperThreading disabled? A. 1 B. 2 C. 4 D. 8 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=135 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 136 Which ProLiant Essential solution enables consolidation of multiple applications onto a single server with service level policies and dynamic resource allocation? A. Rapid Deployment Pack B. Workload Management Pack C. Virtual to Physical Migration Pack D. Physical toProLiant Migration Pack Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=136 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 137 Which factors are affected when enabling the read-ahead cache setting in an MSA1500 disk array? (Select two.) A. increases random I/O read performance B. increases random I/O write performance C. decreases random I/O read performance D. decreases random I/O write performance E. increases performance of sequential transfers F. decreases performance of sequential transfers Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=137 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 138 How does someone claim the standard HP pre-failure warranty provided for ProLiant Servers? A. download and use special pre-failure diagnostic tools from HP to generate a prefailure diagnostic Report. B. use the system EMS option to diagnose and generate a pre-failure replacement report from the system RBSU C. use the replacement alert of a defective part covered by pre-failure warranty from HP Systems Insight Manager events report D. count the total alerts received in a five minute period, and call HP Services for parts replacement if the total is more than three and less than five alerts Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=138 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 139 Which components are covered by HP pre-failure notification on ProLiant servers? (Select threE. ) A. installed system VRM B. installed DIMM modules C. installed processors modules D. intelligent system power supply module E. dynamic system fan module installed in primary slots F. SAS and SCSI hard drives connected to a Smart Array controller Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=139 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 140 Which HP Care Pack Services are available for deployment support? (Select two.) A. software product updates B. proactive software support C. installation of HP hardware D. technology-specific education E. 6-hour call to repair for HP hardware Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=140 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 141 Click the Exhibit button. Which systems have been licensed with HP Performance Management Pack and has captured system performance? (Select two.) A. system sgh70413wy B. system sgh70413xa C. system sgh70413xb D. system home-ews3047277 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=141 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 142 What does the HP Pre-failure warranty provide for ProLiant Server customers? A. 6-hour call to repair of any defective part identified by HP SIM B. repair or replacement of any defective part identified by HP SIM C. repair or replacement of predefined defective parts identified by HP SIM D. replacement of a defective server identified by HP Systems Insight Manager (HP SIM) Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=142 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 143 Click the Exhibit button. Which type of performance analysis is shown in the exhibit? A. HP Operation Center Offline Analysis B. HP Performance Insight Offline Analysis C. HP Performance Insight Online Analysis D. HP Performance Management Pack Offline Analysis E. HP Performance Management Pack Online Analysis Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=143 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 144 Which reports can be generated from the performance information captured by HP Performance Management Pack? (Select three. ) A. Static Analysis Report B. Server Availability Report C. SQL Query Table Report D. System Summary Report E. Power-Performance Relationship Report F. Processor-Core System Bus Performance Relative Report Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=144 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 145 Which tool sets disk thresholds for monitoring and alerting on multiple ProLiant Servers? A. HP Array Diagnostic Utility B. HP Array Configuration Utility C. HP Systems Insight Manager D. HP Performance Management Pack Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=145 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 146 You need to monitor the usable disk capacity on multiple ProLiant servers. Which HP tool enables you to set the thresholds and consolidate the alerts notifications? A. Array Diagnostic Utility B. Systems Insight Manager C. Array Configuration Utility D. System Management Homepage Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=146 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 147 You want to deploy an offline System ROMpaq to a ProLiant Server. Which HP component should you use to accomplish this? A. HBAnywhere Utility B. ROM-based Setup Utility C. HP Command View Utility D. Remote Deployment Utility E. iLO with Virtual Media enabled Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=147 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 148 How does the standard warranty on a ProLiant ML110 Server differ from that of a ProLiant DL380 Server? A. ML110 and DL380 carry the same warranty terms B. 1 year parts and onsite labor for ML110 versus 3 years parts and onsite labor for DL380 C. 3 years parts and onsite labor for ML110 versus 1 year parts and onsite labor for DL380 D. 2 years parts and onsite labor for ML110 versus 3 years parts and onsite labor for DL380 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=148 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 149 How does the standard warranty on a ProLiant DL140 Server differ from that of a ProLiant DL365 Server? A. There is no difference in warranty terms between the DL140 and DL365. B. 1 year parts only for DL140; 3 years parts and onsite labor for DL365 C. 3 years parts only for DL140; 1 year parts and onsite labor for DL365 D. 1 year parts and onsite labor for DL140; 3 years parts and onsite labor for DL365 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=149 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 150 What does the HP Pre-failure warranty provide for ProLiant Server customers? A. 6-hour call to repair of any defective part identified by HP SIM B. repair or replacement of any defective part identified by HP SIM C. repair or replacement of predefined defective parts identified by HP SIM D. replacement of a defective server identified by HP Systems Insight Manager (HP SIM) Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=150 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 151 You are deploying both HP Systems Insight Manager (SIM) and HP Rapid Deployment Pack (RDP) solutions on a single server. After completing the installation, you notice the server and application performance is relatively slow. How can you dynamically optimize the performance and resource utilization of HP SIM and RDP? A. Use HP Performance Management Pack to monitor the bottleneck on that server. B. Use VMware Virtual Infrastructure 3 to isolate the three applications into three virtual machines. C. Use HP Workload Management Pack to partition the resources for HP SIM, RDP, and the database server. D. Use Microsoft Virtual Server to create three separate virtual machines for each HP SIM, RDP, and database server. Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=151 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 152 What is the maximum recommended disk queue length for a RAID 6 (ADG) logical drive from an array set of six physical SAS drives? A. 6 B. 12 C. 24 D. 36 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=152 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 153 You are configuring an external MSA enclosure using a RAID 6 (ADG) configuration. What would be the maximum recommended disk queue length for the logical drive if it has an array set of six physical SAS drives? A. 6 B. 12 C. 18 D. 24 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=153 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 154 Where can you change the HP Performance Management Pack (PMP) data collection interval (sample rate)? A. on the SNMP/Insight Agent Settings page iniLO/iLO 2 of each target server B. on the System Properties page in the HP SIM interface of the Central Management Server C. on the Monitoring Administration page in the PMP interface of the Central Management Server D. on the HP Management Agents Configuration page on the System Management Homepage of the target server Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=154 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 155 You are implementing a performance monitoring solution using HP Systems Insight Manager- Performance Management Pack (PMP) for 350 servers. All the ProLiant servers have ProLiant Support Pack installeD. Prior to deploying the solution, you need to change the data capture interval to every 5 minutes. How do you change that parameter? A. Access each serveriLO 2 and change the parameter in the Insight Agent Setting. B. Access each server RBSU manually and change the hardware data capture parameter. C. Ese iLO 2 scripting and deploy the iLO 2 data interval parameter change script using Rapid Deployment Pack to all the servers. D. Access each server s HP SNMP Management Agents Configuration page on the System Management Homepage and change the data collection parameter. Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=155 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 156 Click the Exhibit button. Given the current settings displayed in the exhibit, when will HP Performance Management Pack (PMP) provide the first performance analysis results after you restart the monitoring of the target server? A. 2 minutes B. 5 minutes C. 10 minutes D. 12 minutes Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=156 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 157 Click the Exhibit button. Based on the information provided in the exhibit, how long must the administrator wait to view the system performance information? A. 12 seconds B. 1 minute C. 2 minutes D. 10 minutes Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=157 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 158 You access a ProLiant DL380 G5 server and change the ProLiant Power Regulator setting to HP Static Lower Power Mode. Which statement is true about this system after the power cycle? A. The processor core speed is clocked down. B. The storage I/O speed is reduced by half, and the hard drives spin at half the rotationalspee D. C. The processor core only switches to low voltage mode if the running operating system supports the power management feature. D. The server must have dual power supply module in order to use this feature; the second power supply module is put into standby mode. Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=158 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 159 How does the standard warranty on a ProLiant ML110 Server differ from that of a ProLiant DL380 Server? A. ML110 and DL380 carry the same warranty terms B. 1 year parts and onsite labor for ML110 versus 3 years parts and onsite labor for DL380 C. 3 years parts and onsite labor for ML110 versus 1 year parts and onsite labor for DL380 D. 2 years parts and onsite labor for ML110 versus 3 years parts and onsite labor for DL380 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=159 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 160 How does the standard warranty on a ProLiant DL140 Server differ from that of a ProLiant DL365 Server? A. There is no difference in warranty terms between the DL140 and DL365. B. 1 year parts only for DL140; 3 years parts and onsite labor for DL365 C. 3 years parts only for DL140; 1 year parts and onsite labor for DL365 D. 1 year parts and onsite labor for DL140; 3 years parts and onsite labor for DL365 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=160 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 161 What does the HP Pre-failure warranty provide for ProLiant Server customers? A. 6-hour call to repair of any defective part identified by HP SIM B. repair or replacement of any defective part identified by HP SIM C. repair or replacement of predefined defective parts identified by HP SIM D. replacement of a defective server identified by HP Systems Insight Manager (HP SIM) Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=161 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 162 A Windows system is considered to have a processor bottleneck if the processor usage is permanently at or above which percentage? A. 75% B. 80% C. 85% D. 90% Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=162 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 163 Using Windows Performance Monitor, what is an indication that Windows Server 2003 has a processor performance bottleneck? A. Processor usage on any core is above 85%. B. Processor usage is permanently at 80% or higher. C. Processor usage on any two processor cores is above 90%. D. Total processor usage hits 75% and sustains for up to 5 seconds. Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=163 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 164 A customer has a RAID 5 disk set consisting of four ULTRA320 disks. At which value does the physical disk:average disk queue length counter indicate a performance bottleneck? A. 2 B. 4 C. 6 D. 8 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=164 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 165 A customer has a SmartArray 6402 RAID 5 array set with eight physical ULTRA320 hot swappable disks. You are monitoring the logical drive performance. Which physical disk:average disk queue length counter value indicates a performance bottleneck? A. 8 B. 12 C. 16 D. 32 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=165 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 166 Which tool establishes a baseline on Windows servers? A. vmstat B. taskmgr C. sysmon D. perfmon Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=166 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 167 Which HP Smart Array utility is designed specifically for Novell NetWare servers? A. CPQONLIN B. CPQDPLOY C. Array Configuration Utility (ACU) D. Option ROM Configuration Utility (ORCA) Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=167 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 168 Which NetWare Loadable Module establishes a baseline on NetWare servers? A. PERF.NLM B. SYSTAT.NLM C. MONITOR.NLM D. PERFMON.NLM Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=168 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 169 Which tool establishes a baseline on Linux servers? A. iostat B. systat C. monitor D. perfrec E. perfmon Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=169 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 170 You deployed a virtualization solution using Microsoft Virtual Server 2005 on a ProLiant server. Each hosting servers has five virtual servers running. You need to capture the new performance baselinE. Which tool provides you this information? A. vmstat B. perfmon C. sysmon D. taskmgr Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=170 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 171 You deploy VMware Server on a Red Hat Enterprise Linux server. Which tool can you use to capture and establish a baseline before setting up any virtual servers? A. systat B. perfrec C. vmmstat D. memstat Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=171 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 172 Which utility stresses the Fibre Channel storage volume to determine the maximum workload it can handle? A. Iiometer B. Array Diagnostic Utility C. Workload Management Pack D. Performance Management Pack Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=172 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 173 Your ProLiant cluster server is connected to an external SAN storage array. You want to verify the SAN storage volume performance approximates your design calculation. Which utility do you use to perform and measure the maximum read/write load to the SAN volume? A. IO meter utility B. EVAPerf Utility C. HBAnywhere Utility D. Array Diagnostic Utility Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=173 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 174 During troubleshooting of an HP solution, what is the next step after developing an action plan to resolve the problem? A. CollectdatA. B. Execute the action plan. C. Implement preventative measures. D. Determine whether the problem issolveD. Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=174 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 175 Which step in the HP Troubleshooting Methodology identifies the cause of failure? A. CollectdatA. B. EvaluatedatA. C. Execute the action plan. D. Develop an optimized action plan. E. Implement preventative measures. F. Determine whether the problem issolveD. Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=175 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 176 You want to deploy an offline System ROMpaq to a ProLiant Server. Which HP component should you use to accomplish this? A. HBAnywhere Utility B. ROM-based Setup Utility C. HP Command View Utility D. Remote Deployment Utility E. iLO with Virtual Media enabled Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=176 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 177 Which URL is used to access data from the Insight Agents version 5.0 running on a remote ProLiant Server with the Windows Server 2003 operating system? A. http://server01.company.com:2301 B. http://server01.company.com:2381 C. https://server01.company.com:2301 D. https://server01.company.com:2381 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=177 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 178 Which URL is used to access data from the Insight Agents version 5.0 running on a remote ProLiant Server with the HP-UX 11 operating system? A. http://server01.company.com:2301 B. http://server01.company.com:2381 C. https://server01.company.com:2301 D. https://server01.company.com:2381 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=178 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 179 Which method allows you to access the Array Diagnostics Utility (ADU)? A. Boot fromSmartStart C D. B. Launch fromProLiant Integration Modul E. C. Boot from Insight Control Data Center Edition DV D. D. Launch from Online Array Configuration Utility (ACU). Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=179 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 180 Which tool runs nonintrusive tests on the drives connected to a Smart Array controller while the operating system is running? A. Fibre Channel Diagnostic Utility B. Array Configuration Utility (ACU) C. Insight Diagnostics Online Edition D. Option ROM Configuration Array (ORCA) Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=180 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 181 Which tool quickly identifies inappropriate error rates on hot-plug hard drives? A. Array Diagnostics Utility (ADU) B. Array Configuration Utility (ACU) C. Fibre Channel Diagnostics Utility D. Option ROM Configuration Array (ORCA) Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=181 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 182 Which utilities can be used to set the unit identification (UID) LED state on a ProLiant Server running Linux? (Select three. ) A. hpuid B. hpasmcli C. /proc/proliant/led D. Array Diagnostics Utility E. Array Configuration Utility F. System Management Homepage Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=182 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 183 You have just established a performance baseline on a problematic server. Which step of the HP Troubleshooting Methodology are you performing? A. collect data B. evaluate data C. execute the action plan D. implement preventive measures E. develop an appropriate action plan F. determine if fault has been resolved Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=183 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 184 What does the Insight Diagnostics Offline Edition provide? (Select two.) A. diagnostic tests B. historical configurations C. operating system status D. information from installed software E. component firmware revision levels Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=184 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 185 Which troubleshooting functions are available only in the Insight Diagnostics Online Edition? (Select two.) A. survey history B. diagnostic tests C. survey historical comparisons D. component firmware revisions E. integrated management logs (IML) Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=185 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 186 Using Insight Diagnostics Online Edition, which tab flashes the LEDs of a failed drive? A. Log B. Help C. Status D. Survey E. Diagnose Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=186 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 187 From a Performance Management Pack (PMP) report, a server administrator notices that the application server s disk queue is saturated. Which part of the HP Troubleshooting Methodology does this reflect? A. CollectdatA. B. Execute plan. C. EvaluatedatA. D. Develop an optimized plan. E. Implement preventative measures. F. Determine if the problem isresolveD. Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=187 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 188 A server administrator is reviewing a Performance Management Pack (PMP) report and finds the application server s disk queue is saturated. This is an example of which step of the HP Troubleshooting Methodology? A. Collect data B. Execute plan C. Evaluate data D. Determine if the problem is resolved Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=188 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 189 You are troubleshooting performance problems on several of ProLiant servers. You have run the Windows perform tool and the processor:processor time counter has produced abnormally high results. You run more tests adding the system:processor queue length counter. From the perfmon results, which systems indicate higher than average processor queue length? (Select three. ) A. system01: 2 processor cores -- average processor queue length = 5 B. system02: 2 processor cores -- average processor queue length = 6 C. system03: 4 processor cores -- average processor queue length = 6 D. system04: 4 processor cores -- average processor queue length = 7 E. system05: 4 processor cores -- average processor queue length = 9 F. system06: 8 processor cores -- average processor queue length = 13 G. system07: 8 processor cores -- average processor queue length = 15 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=189 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 190 You are presenting a comprehensive proposal to replace certain components one by one in order to resolve a problem that appears to be with the disk subsystem on a problematic server. Which step of the HP Troubleshooting Methodology are you performing? A. collect data B. evaluate data C. execute action plan D. implement preventive measures E. develop an appropriate action plan F. determine if fault has been resolved Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=190 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 191 How does Dynamic Sector Repair (DSR) protect against bad sectors? A. DSR uses drive subsystem fault tolerance to replace a bad sector with a spare sector in the same track on the same drive. B. DSR uses drive subsystem fault tolerance to replace a bad sector with a spare sector in a different track on the same drive. C. DSR uses drive subsystem fault tolerance to replace a bad sector with a spare sector in the same track on a different drive. D. DSR uses drive subsystem fault tolerance to replace a bad sector with a spare sector in a different track on a different drive. Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=191 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 192 Which tasks are part of the Execute the Action Plan step of the HP Troubleshooting methodology? (Select three. ) A. understanding the mode of failure B. apply one change or solution at a time C. determine the root cause of the problem D. observe and record the results of each step E. determine proactive steps to prevent further recurrence of the failure F. evaluate information gathered from the implementation of the action plan G. keep your customer informed as to which actions you are taking while executing the action plan Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=192 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 193 You are evaluating the information gathered from the implementation of your action plan on a customer s server. Which step of the HP Troubleshooting Methodology are you performing? A. collect data B. valuate data C. execute action plan D. implement preventive measures E. develop an appropriate action plan F. determine if fault has been resolved Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=193 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 194 How can you avoid HP SIM discovering an orphan_nnn system in a Windows environment? A. Set HP SIM to automatic discovery. B. In HP SIM, configure the web agent to exclude the discovery of orphan systems. C. Delete the registry key entry, HKEY_LOCAL_MACHINE\Software\Compaq\CIMAgent\GUI D. D. Delete the registry key entry, HKEY_LOCAL_MACHINE\Software\Compaq\CIMAgent\Webagent. Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=194 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 195 Which tasks are part of the Implement Preventive Measures step of the HP Troubleshooting Methodology? (Select three. ) A. understanding the mode of failure B. determine the root cause of the problem C. apply one change or one solution at a time D. observe and record the results of each step E. add fault tolerant elements to critical subsystems, where applicable F. determine proactive steps to prevent further recurrence of the failure G. evaluate information gathered from the implementation of the action plan Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=195 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 196 You have finalized a report detailing the root cause of a mode of failure experienced by a customer. Which step of the HP Troubleshooting Methodology have you just completed? A. collect data B. evaluate data C. execute action plan D. implement preventive measures E. develop an appropriate action plan F. determine if fault has been resolved Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=196 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 197 Which networking protocols are used by HP Systems Insight Manager (HP SIM) to identify network devices and gather detailed information from them? (Select four.) A. DMI B. FTP C. SSH D. TFTP E. HTTP F. SNMP G. WBEM Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=197 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 198 When HP Systems Insight Manager (HP SIM) performs network discovery and gathers information from the discovered devices, which protocols are used? (Select four.) A. DMI B. SSH C. Telnet D. HTTP E. SNMP F. WBEM Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=198 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 199 Which protocol obtains the operating system type and version information on a Windows server when you use HP Systems Insight Manager (HP SIM) to gather and manage your network devices? A. DMI B. SSH C. DCOM D. WBEM Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=199 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 200 An HP Systems Insight Manager (HP SIM) performs system query on a Windows-based server and is not able to gather the operating system type and version information. Which service or protocol needs to be enabled on the Windows-based server? A. SSH B. TFTP C. DCOM D. WBEM Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=200 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 201 Click the Exhibit button. You are trying to execute the find command to a remote ProLiant Linux server using the Secure Task Execution option in HP Systems Insight Manager (HP SIM). However, the task cannot be completed by HP SIM. Which component is missing between the Linux server and HP SIM? A. DMI B. FTP C. SSH D. WBEM Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=201 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 202 Click the Exhibit button. Which component is required in order to execute the find command to a remote ProLiant server running a Linux operating system? A. SSH B. Tomcat C. Apache D. WBEM Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=202 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 203 Which component can be integrated with HP Systems Insight Manager for Windows to provide complete end-to-end storage environment management including provisioning, capacity management, and monitoring of the SAN? A. SANSurfer B. CommandView EVA and XP C. CommandView ESL and VLS D. Storage Essentials Enterprise Edition Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=203 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 204 You need a complete end-to-end unified infrastructure management solution that enables proactive management of servers and storage in the data center. Which components enable provisioning, capacity management and health monitoring of the servers and storage arrays? (Select two.) A. SANSurfer B. CommandView C. Storage Essentials D. Systems Insight Manager E. Reference Information Storage System Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=204 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 205 Which functionalities can the combination of HP Virtual Machine Management and Server Migration Pack perform to simplify the server consolidation process? (Select three. ) A. Virtual to Virtual migration B. Physical to Virtual migration C. Virtual to Physical migration D. ProLiant to Integrity migration E. Physical toProLiant migration Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=205 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 206 Which component must be deployed to the managed server to discover and manage relationships between Virtual Machines and Virtual Machine Hosts within HP Systems Insight Manager? A. Server Migration Pack Agent B. Virtual Server Environment Agent C. Virtual Machine Management Agent D. HP Systems Insight Management Agent Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=206 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 207 Which component must be deployed to the target virtual machine host server to migrate legacy servers into a virtual machine using HP Systems Insight Manager solution? A. VMtool kit B. Server Migration tool kit C. Virtual Machine Management Agent D. HP Systems Insight Management Agent Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=207 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 208 You are not able to detect all the virtual machine guest systems in an VMware ESX host. What must be installed to establish a relationship to HP Systems Insight Manager? A. Server Migration Pack Agent B. Virtual Server Environment Agent C. Virtual Machine Management Agent D. HP Systems Insight Management Agent Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=208 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 209 You are performing a migration from a ProLiant DL380 G2 server to a Virtual Machine (guest) hosted on VMware ESX server. Which component must be deployed in the ESX server? A. VMware tool kit B. Server Migration tool kit C. Virtual Machine Management Agent D. HP Systems Insight Management Agent Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=209 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 210 A customer escalated a performance issue with HP ProLiant DL380 Servers after upgrading memory and additional network adapters. Which tools enable you to capture, monitor, and analyze server performance and identify why the server is slow after the upgrade? (Select two.) A. HP Systems Insight Manager B. HP Upgrade Management Pack C. HP Performance Management Pack D. HP Insight Power Management Pack E. HP Vulnerability and Patch Management Pack Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=210 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 211 Which tools are required to capture and analyze the utilization of a DL380 server system bus and I/O after performing a system memory upgrade? (Select two.) A. HP Systems Insight Manager B. HP Upgrade Management Pack C. HP Performance Management Pack D. HP Insight Power Management Pack E. HP Vulnerability and Patch Management Pack Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=211 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 212 Which HP component remotely deploys an offline System ROMpaq update to a ProLiant Server? A. ROM-based Setup Utility B. Remote Deployment Utility C. Insight Control Linux Edition D. iLO with Virtual Media enabled Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=212 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 213 Which types of move operations can be performed when using HP Virtual Machine Management Pack together with VMware Virtual Infrastructure 3 as a complete solution? (Select threE. ) A. live B. SAN C. NFS D. CIFS E. offline Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=213 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 214 Which component is required to perform the data copy and migration of a legacy source server to a ProLiant Server using HP Server Migration Pack - Physical to ProLiant Edition solution? A. MicrosoftiSCSI Initiator software B. HPStorageWorks EVA iSCSI gateway C. anyiSCSI networked storage disk array D. HPProLiant Storage Server with iSCSI Features Pack Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=214 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 215 Which component is responsible for the data copy process from a legacy source server to a new ProLiant Server using HP Server Migration Pack? A. Microsoft MPIO software B. MicrosoftiSCSI software C. HPSecurePath software D. HPProLiant Storage Server with iSCSI Features Pack Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=215 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 216 Which component functions as the management console for HP Workload Management Pack on a ProLiant Server running Microsoft Windows Server 2003? A. HP Partitioning Manager B. HP Systems Insight Manager C. Resource Partitioning Manager D. Microsoft Management Console Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=216 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 217 Which types of resources can you allocate to each partition when using HP Workload Management Pack on a ProLiant Server running Microsoft Windows Server 2003? (Select two.) A. disk resources B. memory resources C. processor resources D. Array Accelerator allocation E. network adapters teaming bandwidth Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=217 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 218 How does HP Virus Throttle prevent viruses from quickly spreading from the infected server? A. It monitors network traffic for large UDP inbound networktraffi C. B. It detects network traffic packets for specific virus binary signatures. C. It analyzes network packets for jumbounicast and multicast packet traffi C. D. It monitors network traffic for abnormal behavior in outbound TCP connection request. Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=218 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 219 Which components are required to implement the HP Insight Power Management Solution? (Select three. ) A. HPiLO Select Pack B. HPiLO Advanced Pack C. HP Insight Power Manager D. HP Systems Insight Manager E. HP Intelligent Networking Pack F. HP Performance Management Pack Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=219 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 220 Which licensed components are included when you install the HP iLO Power Management Pack? (Select three. ) A. HPiLO Select Pack B. HPiLO Advanced Pack C. HP Server Migration Pack D. HP Insight Power Manager E. HP Systems Insight Manager F. HP Performance Management Pack Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=220 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 221 Which HP Essential Pack enables direct memory communication between two servers using the Multifunction NIC on a ProLiant Server or BladeSystem mezzanine card with minimal demand on the host processor? A. RDMA Pack B. Virtual Connect Pack C. iSCSI Acceleration Pack D. InfiniBand Networking Pack Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=221 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 222 Which component is required for a complete integration of HP Systems Insight Manager and HP Virtual Management Software (VMM and SMP) with a VMware Infrastructure 3 solution such as VMotion? A. VMware Virtual Center Server B. Microsoft Management Console C. VMware Virtual Infrastructure Client D. Red Hat Enterprise Linux Virtual Console Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=222 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 223 Which component is required for a complete integration of HP Systems Insight Manager and HP Virtual Management Software (VMM and SMP) with a VMware Infrastructure 3 solution such as VMotion? A. VMware Virtual Center Server B. VMware Consolidated Backup C. Microsoft Virtual Machine Converter D. Microsoft System Center Operation Manager Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=223 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 224 Click the Exhibit button. Which statement correctly describes the end result when the Rapid Deployment job in the Exhibit completes? A. The deployed server will be part of the HPTRNG workgroup. B. The deployed server will automatically join the Active Directory it firstdetecte D. C. The deployed server will join the default Windows Active Directory defined in the DNS entry. D. The deployed server will require the default Administrator to log in and set the workgroup or Active Directory settings. Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=224 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 225 Click the Exhibit button. What happens when the Rapid Deployment job shown in the exhibit completes? A. The deployed server will have SNMP and WBEMenable D. B. The deployed server will automatically join the HPTRNG Active Directory domain. C. The deployed server will join the first default Windows Active Directory defined in the DNS entry. D. The deployed server will require the administrator to enter the default password during installation. Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=225 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 226 When deploying an HP Virtual Machine Management Pack solution, you use OpenSSH communication between HP Systems Insight Manager and the Windows hosts. What does OpenSSH provide between these two systems? A. a broadcast type network that uses encryption between the systems B. encryption of online traffic which helps eliminate network-level attacks C. a secure, encrypted and fault tolerance network VLAN between the systems D. a multicast type network communication that has fault tolerance and high performance Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=226 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 227 Which types of licensing options are available for HP Virtualization Management Software? (Select three. ) A. Tracking license B. Single-server license C. Flexible-quantity license D. Corporate Value License E. Try-Buy 24-hours license F. Instant On-Demand license Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=227 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 228 Which Virtual Machine Management tasks can be initiated from the HP Systems Insight Manager toolbar? (Select three. ) A. copying a virtual machine guest B. restoring a virtual machine guest backup C. creating a virtual machine guest template D. performing image backup of a virtual machine guest E. instant halting of a virtual machine guest operating system Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=228 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 229 What is a "template" in the Virtual Machine Management solution? A. an image of a complete virtual machine host B. an image of a complete virtual machine guest C. a guideline that contains virtual machine disk information without an operating system D. a configuration file containing information such as UUID and MAC address of a new virtual machine guest Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=229 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 230 You have a VMware Virtual Infrastructure 3 solution that uses HP Systems Insight Manager and HP Virtualization Management Solution. Which types of virtual machine migration can you perform? (Select threE. ) A. VMotion B. Cold migrate C. Snap migrate D. StorageVMotion E. VM backup migrate Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=230 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 231 Click the Exhibit button. Which components within the HP ProLiant Essentials solution provide the report shown in the exhibit? (Select two.) A. HP Systems Insight Manager B. HP Remote Support Services C. HP Patch Management Reporter D. HP Client Patch Control Manager E. HP Version Control Repository Manager Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=231 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 232 Click the Exhibit button. Which components version control and upgrades are managed by the services shown in the exhibit? (Select two.) A. HP Systems Insight Manager B. HP Remote Support Services C. HP Patch Management Reporter D. HP Client Patch Control Manager E. HP Version Control Repository Manager Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=232 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 233 Click the Exhibit button. Which component within the HP Systems Insight Management solution enables the proactive support and notification of component failure to HP Support so the component covered under the warrantee is replaced as soon as possible? A. HP Auto Support Caller B. Proactive Notification Engine C. Open Service Event Manager D. Properties Scanner Extension Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=233 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 234 Click the Exhibit button. Which component, which is part of HP Insight Control Environment installation provides proactive support, notification to HP Support and enables tracking of hardware covered under warranty? A. HP Auto Support Caller B. Open Service Event Manager C. Proactive Notification Engine D. Properties Scanner Extension Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=234 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 235 What is the maximum number of logical drives that can be configured on a Smart Array controller using the Array Configuration Utility (ACU)? A. 4 B. 8 C. 16 D. 32 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=235 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 236 Your customer wants to add 14 new logical drives to an existing MSA1500 that contains 20 logical drives. How many logical drives must the customer remove in order to meet the maximum number of logical drives that can be configured on a single Smart Array controller using the Array Configuration Utility (ACU)? A. 2 B. 4 C. 6 D. 8 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=236 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 237 You have a ProLiant Server with a single MSA1500cs storagE. The system is currently configured for 8 logical drives. What is the maximum number of logical drives that can be added? A. 6 B. 8 C. 16 D. 24 Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=237 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 238 You are planning an upgrade to the capacity of online storagE. Which parameters must you consider because they have an effect on the amount of time required? (Select two.) A. logical drive size B. amount of other I/O work the server is processing C. amount of physical memory installed in the system D. priority level of the rebuild operation set in the Array Configuration Utility (ACU) Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=238 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 239 What are possible causes of an unknown status icon on the Version Control Agent (VCA) homepage? (Select two.) A. Port 21 is being blocked by a firewall. B. The VCRM password is casesensitiv E. C. The VCA does not have a VCRMconfigure D. D. The VCRM does not respond to FTP requests. E. The Version Control Repository Manager (VCRM) user id is casesensitivE. Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=239 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 240 When viewing the Version Control Agent (VCA) homepage, what can cause an unknown status icon to appear? (Select two.) A. a case sensitive VCRM user ID B. port 21 being blocked by a firewall C. the VCRM not responding to HTTP requests D. an incorrect VCRM password entered in VCA E. not configuring VCRM in the VCA on the server that is displaying the unknown status Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=240 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 241 Which method restricts logical drive access on an MSA1500cs? A. port-based zoning B. Selective Volume Presentation (SVP) C. Selective Storage Presentation (SSP) D. World Wide Name based (WWN-based) zoning Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=241 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 242 A junior administrator asks for assistance in restricting access to a logical drive on an MSA1510 so that only one server can access a logical disk. What should the administrator use to accomplish this? A. port-based zoning B. Selective Volume Presentation (SVP) C. Selective Storage Presentation (SSP) D. World Wide Name based (WWN-based) zoning Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=242 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 243 When performing an online drive firmware upgrade, at which point is the firmware on the drive actually upgraded? A. during the next reboot B. immediately as part of the upgrade process C. during a period of low I/O activity on the drive D. during a period of low I/O activity on the controller Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=243 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 244 You are performing an online drive firmware upgrade on a set of RAID 1 mirrored disks. When is the firmware on each drive actually upgraded? A. during the next reboot B. when there is low I/O activity on the drive C. immediately as part of the upgrade process D. when there is low I/O activity on the controller E. after the drive is taken out of the mirror, upgraded and returned to the mirror set Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=244 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 245 What is required to connect a ProLiant Windows 2003 Server to both an MSA1500 active/active and an EVA8000? A. HPAutopath installed on the host B. MPIO Full Feature installed on the host C. MPIO Basic and HP Secure Path installed on the host D. MPIO Full Feature and MPIO Basic installed on the host Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=245 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 246 In order to connect to an MSA1500 active/active and an EVA8000 storage array, which software must be installed on a ProLiant server running Windows Server 2003? A. HPAutopath B. MPIO Full Feature C. MPIO Basic and HPSecurePath D. MPIO Full Feature and MPIO Basic Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=246 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 247 Starting with the ProLiant Support Pack (PSP) 7.20 and higher, which predeployment requirement changed? A. Componentpreconfiguration is optional. B. You must specify a user id and password for the VCA. C. You must specify the Version Control Agent (VCA) IP address. D. You must specify the Version Control Repository Manager (VCRM) servernamE. Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=247 ------------------------------------------------------------------------------------------------------------------------------------- QUESTION: 248 Which predeployment requirement change was introduced in ProLiant Support Pack (PSP) 7.20? A. Preconfiguration of components was no longer mandatory. B. An IP address must be specified for the Version Control Agent (VCA). C. A user ID and password must be specified for the Version Control Agent (VCA). D. The Version Control Repository Manager (VCRM) server name must bespecifieD. Answer: http://www.twpass.com/twpass.com/exam.aspx?ecode=HP0-S11&qno=248 ------------------------------------------------------------------------------------------------------------------------------------- TwPass Certification Exam Features; - TwPass offers over 2500 Certification exams for professionals. More than 98,800 Satisfied Customers Worldwide. Average 99.8% Success Rate. Over 120 Global Certification Vendors Covered. Services of Professional & Certified Experts available via support. Free 90 days updates to match real exam scenarios. Instant Download Access! No Setup required. Price as low as $19, which is 80% more cost effective than others. Verified answers researched by industry experts. Study Material updated on regular basis. Questions / Answers are downloadable in PDF format. Mobile Device Supported (Android, iPhone, iPod, iPad) No authorization code required to open exam. Portable anywhere. Guaranteed Success. Fast, helpful support 24x7. View list of All Exams (AE); http://www.twpass.com/twpass.com/vendors.aspx Download Any Certication Exam DEMO. http://www.twpass.com/twpass.com/vendors.aspx To purchase Full version of exam click below; http://www.TwPass.com/