Hpa 4 Centrifugal

   EMBED


Share

Transcript

Product Specification 930091-0016 HPA4 (60 Hz) Air Source Heat Pump For Water Heating General - Colmac HPA heat pumps can be successfully applied wherever there is a need for large amounts of hot water and there is a source of warm air available. The Colmac HPA is best suited for supplying hot water in facilities where demands for hot water and space cooling are concurrent. Apartments, Condominiums, Hotels, Hospitals, Dormitories, Restaurants, Nursing Homes, Laundries, Kitchens, Food Processing Plants, and Photographic Processing Plants located in warm climates are a few of the possible heat sources that can be utilized by the HPA heat pump. Depending on the temperature of the waste heat source, the HPA can produce potable hot water for as little as 1/4 the energy used by a conventional boiler or electric resistance heater. These packaged air source water heating pumps are factory wired, charged, and tested. Low operating noise levels, high capacity, high efficiency, and environmentally safe refrigerants are integrated into this new design. General Specifications:     Water Heating Capacity *: Cooling Capacity *: Heating COP *: Cooling COP *: 66.1 MBH 52.6 MBH 4.9 3.9 * 70°F Potable Water Inlet, 140°F Potable Water Outlet, 75°F Entering Air Wet Bulb Standard Features:          Environmentally friendly R134a refrigerant. Copeland scroll compressor. Vented double wall, stainless steel, brazed plate condensers (potable water). Adjustable TXV, moisture indicating sight glass, liquid line filter drier. Bronze hot water circulating pump (potable water). TM Electronic temperature control valve (e-TCV ) Factory built and tested copper tube, aluminum fin evaporators. Automatic controls include high and low pressure cutouts, compressor time delay relay, normal run and fault indicating lights, phase failure relay. Fully enclosed cabinets are offered in mill finish aluminum, galvanized steel, 304 SST, and 316 SST. Performance Data 100 F LWT 120 F LWT 140 F LWT 160 F LWT 85 80 75 70 65 60 55 50 45 40 120 F LWT 140 F LWT 160 F LWT 80 70 60 50 40 30 20 40 60 80 40 100 HPA4 Heating COP vs. Entering Air Temperature 100 F LWT 80 HPA4 Cooling COP vs. Entering Air Temperature 120 F LWT 140 F LWT 160 F LWT 9.5 60 100 Entering Air Wet Bulb ( F) Entering Air Wet Bulb ( F) 100 F LWT 120 F LWT 140 F LWT 160 F LWT 8 8.5 7 7.5 Cooling COP Heating COP 100 F LWT HPA4 Cooling Capacity vs. Entering Air Temperature Cooling Capacity (MBH) Heating Capacity (MBH) HPA4 Heating Capacity vs. Entering Air Temperature COLMAC WaterHeat 6.5 5.5 4.5 3.5 6 5 4 3 2 2.5 1.5 1 40 60 80 100 40 Entering Air Wet Bulb ( F) 60 80 Entering Air Wet Bulb ( F) Note: Based on entering potable water temperature of 70°F. 930091-0016 100 COLMAC WaterHeat Unit Dimensions 24 [610] 24 [610] 24 [610] 24 [610] SERVICE CLEARANCE AIR FLOW AIR FLOW 33 3/4 [857] 41 3/4 [1060] MECHANICAL ACCESS 20 3/4 [526] ELECTRICAL ACCESS Unit Weight Dry Weight: Crated Weight: 361 Lbs. 390 Lbs. Electrical Data Line Voltage Rated Load Amps (RLA) Locked Rotor Amps (LRA) 208-230/60/1 208-230/60/3 460/60/3 27.7 A 22.6 A 11.7 A 144 A 128 A 63 A 930091-0016 COLMAC WaterHeat Colmac reserves the right to change product design and specifications without notice. For more information on Colmac products call us at 1-800-926-5622 or visit us online at: WWW.COLMACWATERHEAT.COM 930091-0016