Transcript
HR 12-270W High Rate Series SLA Battery RANGE SUMMARY By combining proprietary high rate plate design with low internal resistance AGM separators, BSB created the innovative High Rate range of batteries. This range offers extremely high power output at 15 minutes backup time with 12 years design life and is highly suited to high rate UPS and power switchgear applications.
Application Alarm System Cable Televison Communication Equipment Control Equipment
Security System Medical Equipment Toys UPS Emergency Power System
General Features · Sealed and maintenance free operation. · Non-Spillable construction design. · ABS containers and covers(UL94 V0, optional). · Safety valve installation for explosion proof. · High quality and high reliability. · Exceptional deep discharge recovery performance. · Low self discharge characteristic. · Flexible design for multiple installation positions.
3mm (0.12inch)
14mm (0.55inch)
M6mm (0.24inch)
Construction Positive ...... Negative ...... Container ...... ...... Cover Sealant ......
Lead dioxide Lead ABS ABS Epoxy Resin
Safety valve Terminal Separator Electrolyte
...... ...... ...... ......
EPDR Copper AGM Sulfuric acid
214mm(8.43inch)
168mm(6.61inch)
211mm(8.31inch)
260mm(10.2inch)
Terminal Dimensions
Battery Model
HR12-270 (270W to 1.67V, 15min)
Designed Floating Life
12 Years
Capacity(20oC)
Dimensions
20HR(4.5A,1.80V)
10HR(8.5A,1.80V)
5HR(15.2A,1.75V)
90AH
85AH
76AH
Length
Width
Height
Total Height
260mm(10.2inch)
168mm(6.62inch)
211mm(8.31inch)
214mm(8.43inch)
60AH
Approx. Weight
25Kg (55.1 lbs)
Internal Resistance
Full charged at 20oC: 0.006 Ohm
Self Discharge
3% of capacity declined per month at (20oC)
Capacity Affected by Temp.(20HR) Charge Voltage(20oC)
1HR(60.4A,1.60V)
40oC
20oC
0oC
-15oC
102%
100%
85%
65%
Cycle use 14.4-14.8V(-30mV/ oC), max. Current: 21A
Page 1 of 2
Float use 13.6-13.8V(-20mV/ oC)
HR 12-270W
Charge Voltage
Constant Charge At 0.25CA-2.30V (20 C)
(CA) (V/Cell)
100 80
0.25
Charge Capacity
Charge Voltage
2.17 100%Discharge
0.20
60
2.00
50%Discharge
0.15
40
0.10 20
1.83
0.05
0
0
Charge Current
0
2
4
6
8
10
2.17 2.00 1.83 0.25CA 0.1CA 0.05CA
1.67 1.60
3CA
2CA
1CA
6
12
30
0.6CA
1.33 0
12
2
60
3
Min
Time(hour)
10 Hour
20
Self Discharge Characteristics
Relationship of OCV and state of charge 110 105
2.25
2.17
Capacity (%)
Battery Voltage (V/Cell)
o
(20 C)
o
120 2.33
Discharge Characteristic
Charge Characteristic Discharge Voltage (V/Cell)
(%)
Current
Charge
Charge Capacity
High Rate Series SLA Battery
2.08
2.00
100 95 90 85 80 75 70 65 60 55 50
1.92
o
0
10
20
30
40
50
60
70
80
90
100
40
0
1
2
20oC
o
40 C
45
1.83
30 C 3
4
5
6
7 8
9 10 11 12 13 14 15 16 17 18 19 20
Storage time:months
Remained Capacity(%)
Constant current discharge ratings-amperes at 20oC F. V/ Tim e
5M I N
1 0MI N
15 MI N
30 MI N
1 HR
3HR
5 HR
10 HR
2 0HR
1 .6 0V
3 19
19 9
1 50
91 . 3
6 0. 4
26 . 5
1 6. 2
8. 8 3
5 . 01
1 .6 7V
2 99
18 8
1 44
87 . 4
5 9. 6
25 . 5
1 5. 9
8. 7 4
4 . 83
1 .7 0V
2 74
18 2
1 41
79 . 4
5 7. 8
23 . 8
1 5. 5
8. 7 1
4 . 76
1 .7 5V
2 69
17 6
1 36
75 . 4
5 5. 1
23 . 0
1 5. 2
8. 6 7
4 . 63
1 .8 0V
2 41
16 8
1 24
69 . 9
5 1. 6
22 . 1
1 4. 3
8. 5 0
4 . 50
1 .8 5V
2 12
16 0
1 11
64 . 3
4 8. 1
21 . 3
1 3. 4
8. 3 8
4 . 38
Constant power discharge ratings-watts at 20oC F. V/ Tim e
5M I N
1 0MI N
15 MI N
30 MI N
1 HR
3HR
5 HR
10 HR
2 0HR
1 .6 0V
5 60
35 8
2 73
16 4
1 09
47 . 0
2 7. 4
18 . 1
9 . 52
1 .6 7V
5 40
34 9
2 70
16 1
1 08 .3
45 . 6
2 7. 3
18 . 0
9 . 18
1 .7 0V
5 09
34 6
2 68
15 1
1 06 .3
43 . 5
2 6. 9
17 . 9
9 . 07
1 .7 5V
5 12
34 5
2 65
14 6
1 04 .5
42 . 5
2 6. 7
17 . 6
8 . 84
1 .8 0V
4 68
34 0
2 46
14 0
9 8. 5
41 . 3
2 5. 9
16 . 6
8 . 61
1 .8 5V
4 25
32 2
2 23
13 1
9 2. 6
40 . 0
2 5. 0
16 . 4
8 . 33
ISO9001