Preview only show first 10 pages with watermark. For full document please download

Hr12 270w

   EMBED


Share

Transcript

HR 12-270W High Rate Series SLA Battery RANGE SUMMARY By combining proprietary high rate plate design with low internal resistance AGM separators, BSB created the innovative High Rate range of batteries. This range offers extremely high power output at 15 minutes backup time with 12 years design life and is highly suited to high rate UPS and power switchgear applications. Application Alarm System Cable Televison Communication Equipment Control Equipment Security System Medical Equipment Toys UPS Emergency Power System General Features · Sealed and maintenance free operation. · Non-Spillable construction design. · ABS containers and covers(UL94 V0, optional). · Safety valve installation for explosion proof. · High quality and high reliability. · Exceptional deep discharge recovery performance. · Low self discharge characteristic. · Flexible design for multiple installation positions. 3mm (0.12inch) 14mm (0.55inch) M6mm (0.24inch) Construction Positive ...... Negative ...... Container ...... ...... Cover Sealant ...... Lead dioxide Lead ABS ABS Epoxy Resin Safety valve Terminal Separator Electrolyte ...... ...... ...... ...... EPDR Copper AGM Sulfuric acid 214mm(8.43inch) 168mm(6.61inch) 211mm(8.31inch) 260mm(10.2inch) Terminal Dimensions Battery Model HR12-270 (270W to 1.67V, 15min) Designed Floating Life 12 Years Capacity(20oC) Dimensions 20HR(4.5A,1.80V) 10HR(8.5A,1.80V) 5HR(15.2A,1.75V) 90AH 85AH 76AH Length Width Height Total Height 260mm(10.2inch) 168mm(6.62inch) 211mm(8.31inch) 214mm(8.43inch) 60AH Approx. Weight 25Kg (55.1 lbs) Internal Resistance Full charged at 20oC: 0.006 Ohm Self Discharge 3% of capacity declined per month at (20oC) Capacity Affected by Temp.(20HR) Charge Voltage(20oC) 1HR(60.4A,1.60V) 40oC 20oC 0oC -15oC 102% 100% 85% 65% Cycle use 14.4-14.8V(-30mV/ oC), max. Current: 21A Page 1 of 2 Float use 13.6-13.8V(-20mV/ oC) HR 12-270W Charge Voltage Constant Charge At 0.25CA-2.30V (20 C) (CA) (V/Cell) 100 80 0.25 Charge Capacity Charge Voltage 2.17 100%Discharge 0.20 60 2.00 50%Discharge 0.15 40 0.10 20 1.83 0.05 0 0 Charge Current 0 2 4 6 8 10 2.17 2.00 1.83 0.25CA 0.1CA 0.05CA 1.67 1.60 3CA 2CA 1CA 6 12 30 0.6CA 1.33 0 12 2 60 3 Min Time(hour) 10 Hour 20 Self Discharge Characteristics Relationship of OCV and state of charge 110 105 2.25 2.17 Capacity (%) Battery Voltage (V/Cell) o (20 C) o 120 2.33 Discharge Characteristic Charge Characteristic Discharge Voltage (V/Cell) (%) Current Charge Charge Capacity High Rate Series SLA Battery 2.08 2.00 100 95 90 85 80 75 70 65 60 55 50 1.92 o 0 10 20 30 40 50 60 70 80 90 100 40 0 1 2 20oC o 40 C 45 1.83 30 C 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Storage time:months Remained Capacity(%) Constant current discharge ratings-amperes at 20oC F. V/ Tim e 5M I N 1 0MI N 15 MI N 30 MI N 1 HR 3HR 5 HR 10 HR 2 0HR 1 .6 0V 3 19 19 9 1 50 91 . 3 6 0. 4 26 . 5 1 6. 2 8. 8 3 5 . 01 1 .6 7V 2 99 18 8 1 44 87 . 4 5 9. 6 25 . 5 1 5. 9 8. 7 4 4 . 83 1 .7 0V 2 74 18 2 1 41 79 . 4 5 7. 8 23 . 8 1 5. 5 8. 7 1 4 . 76 1 .7 5V 2 69 17 6 1 36 75 . 4 5 5. 1 23 . 0 1 5. 2 8. 6 7 4 . 63 1 .8 0V 2 41 16 8 1 24 69 . 9 5 1. 6 22 . 1 1 4. 3 8. 5 0 4 . 50 1 .8 5V 2 12 16 0 1 11 64 . 3 4 8. 1 21 . 3 1 3. 4 8. 3 8 4 . 38 Constant power discharge ratings-watts at 20oC F. V/ Tim e 5M I N 1 0MI N 15 MI N 30 MI N 1 HR 3HR 5 HR 10 HR 2 0HR 1 .6 0V 5 60 35 8 2 73 16 4 1 09 47 . 0 2 7. 4 18 . 1 9 . 52 1 .6 7V 5 40 34 9 2 70 16 1 1 08 .3 45 . 6 2 7. 3 18 . 0 9 . 18 1 .7 0V 5 09 34 6 2 68 15 1 1 06 .3 43 . 5 2 6. 9 17 . 9 9 . 07 1 .7 5V 5 12 34 5 2 65 14 6 1 04 .5 42 . 5 2 6. 7 17 . 6 8 . 84 1 .8 0V 4 68 34 0 2 46 14 0 9 8. 5 41 . 3 2 5. 9 16 . 6 8 . 61 1 .8 5V 4 25 32 2 2 23 13 1 9 2. 6 40 . 0 2 5. 0 16 . 4 8 . 33 ISO9001 COPYRIGHT BSB POWER COMPANY LIMITED Page 2 of 2