Preview only show first 10 pages with watermark. For full document please download

Hr12 55w

   EMBED


Share

Transcript

HR 12-55W High Rate Series SLA Battery RANGE SUMMARY By combining proprietary high rate plate design with low internal resistance AGM separators, BSB created the innovative High Rate range of batteries. This range offers extremely high power output at 15 minutes backup time with 12 years design life and is highly suited to high rate UPS and power switchgear applications. Application Alarm System Cable Televison Communication Equipment Control Equipment Security System Medical Equipment Toys UPS Emergency Power System General Features · Sealed and maintenance free operation. · Non-Spillable construction design. · ABS containers and covers(UL94 V0, optional). · Safety valve installation for explosion proof. · High quality and high reliability. · Exceptional deep discharge recovery performance. · Low self discharge characteristic. · Flexible design for multiple installation positions. Safety valve Terminal Separator Electrolyte ...... ...... ...... ...... EPDR Copper AGM Sulfuric acid Terminal Dimensions 95mm(3.74inch) 101mm(3.98inch) Lead dioxide Lead ABS ABS Epoxy Resin 151mm(3.86inch) 98mm(3.86inch) Battery Model HR12-55W Designed Floating Life Capacity(20oC,at 1.67Vpc) Dimensions 3.15mm(0.124inch) 6.35mm(0.250inch) Construction Positive ...... Negative ...... Container ...... ...... Cover Sealant ...... 12 Years 10min 15min 30min 1h 71Wpc 55Wpc 32.8Wpc 16.6Wpc Length Width Height Total Height 151mm(5.94inch) 98mm(3.86inch) 95mm(3.74inch) 101mm(3.98inch) Approx. Weight 4.0Kg (8.82 lbs) Internal Resistance Full charged at 20oC: 0.021 Ohm Self Discharge 3% of capacity declined per month at (20oC) Capacity Affected by Temp.(20HR) Charge Voltage(20oC) 0.8mm(0.031inch) 6.35mm(0.250inch) 40oC 109% 20oC 0oC -15oC 100% 85% 65% Cycle use 14.4-14.8V(-30mV/ oC), max. Current: 3.9A Page 1 of 2 Float use 13.6-13.8V(-18mV/ oC) HR 12-55W Charge Voltage (CA) (V/Cell) (%) 120 100 0.25 o Constant Charge at 0.25CA-2.40V (20 C) Charge Capacity Charge Voltage 2.40 80 2.20 100%Discharge 0.20 60 2.00 50%Discharge 0.15 40 0.10 20 1.80 0.05 0 0 Discharge Characteristic (20oC) Charge Characteristic Charge Current 0 2 4 6 8 10 Discharge Voltage (V/Cell) Current Charge Charge Capacity High Rate Series SLA Battery 2.17 2.00 1.83 0.25CA 1.67 3CA 1.50 0 12 2 6 2.25 110 105 2.17 100 95 90 Capacity (%) Battery Voltage (V/Cell) 30 0.6CA 60 3 10 Hour 20 Self Discharge Characteristics Relationship of OCV and state of charge 2.00 12 1CA Min Time(hour) 2.08 2CA 0.1CA 0.05CA 85 80 75 70 65 60 55 50 1.92 1.83 45 0 10 20 30 40 50 60 70 80 90 100 40 0 o 1 2 20oC o 40 C 30 C 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Storage time:months Remained Capacity(%) Constant current discharge ratings-amperes at 20oC F .V /Tim e 1.6 0 V 1.6 7 V 1.7 0 V 1.7 5 V 1.8 0 V 1.8 5 V 5m in 65 .0 61 .0 55 .9 54 .8 49 .0 43 .3 10 m in 40 .4 38 .4 37 .0 35 .8 34 .2 32 .6 1 5m in 3 0.5 2 9.3 2 8.7 2 7.7 2 5.2 2 2.6 3 0m in 1 8 .6 1 7 .8 1 6 .2 1 5 .4 1 4 .2 1 3 .1 4 5 m in 1 2 .4 1 2 .0 1 1 .3 1 0 .7 1 0 .0 9 .26 1h 9 .2 3 9 .1 1 8 .8 3 8 .4 2 7 .8 8 7 .3 4 1 .5h 6.6 4 6.5 0 6.2 3 5.9 6 5.6 3 5.3 0 2h 5.3 5 5.2 0 4.9 3 4.7 4 4.5 0 4.2 8 3h 4 .05 3 .90 3 .64 3 .51 3 .38 3 .26 4 5 m in 2 2 .3 2 2 .0 2 1 .1 2 0 .6 1 9 .5 1 8 .3 1h 16 .7 16 .6 16 .2 16 .0 15 .0 14 .1 1 .5h 4.4 7 4.4 1 4.2 9 4.2 1 4.0 0 3.8 0 2h 9 .5 5 9 .3 6 9 .0 5 8 .8 6 8 .4 9 8 .1 2 3h 7 .19 6 .96 6 .65 6 .49 6 .30 6 .11 Constant power discharge ratings-watts at 20oC F .V /Tim e 1 .6 0 V 1 .6 7 V 1 .7 0 V 1 .7 5 V 1 .8 0 V 1 .8 5 V 5 m in 1 14 1 10 1 04 99 .6 95 .4 86 .5 10 m in 7 3.0 7 1.2 7 0.5 7 0.0 6 9.2 6 5.7 1 5m in 5 5.7 5 5.0 5 4.5 5 4.1 5 0.1 4 5.5 3 0m in 3 3 .5 3 2 .8 3 0 .7 2 9 .8 2 8 .4 2 6 .6 ISO9001 COPYRIGHT BSB POWER COMPANY LIMITED Page 2 of 2 (Updated: 1-Nov-2010)