Transcript
HR 12-55W High Rate Series SLA Battery RANGE SUMMARY By combining proprietary high rate plate design with low internal resistance AGM separators, BSB created the innovative High Rate range of batteries. This range offers extremely high power output at 15 minutes backup time with 12 years design life and is highly suited to high rate UPS and power switchgear applications.
Application Alarm System Cable Televison Communication Equipment Control Equipment
Security System Medical Equipment Toys UPS Emergency Power System
General Features · Sealed and maintenance free operation. · Non-Spillable construction design. · ABS containers and covers(UL94 V0, optional). · Safety valve installation for explosion proof. · High quality and high reliability. · Exceptional deep discharge recovery performance. · Low self discharge characteristic. · Flexible design for multiple installation positions.
Safety valve Terminal Separator Electrolyte
...... ...... ...... ......
EPDR Copper AGM Sulfuric acid
Terminal Dimensions
95mm(3.74inch)
101mm(3.98inch)
Lead dioxide Lead ABS ABS Epoxy Resin
151mm(3.86inch)
98mm(3.86inch)
Battery Model
HR12-55W
Designed Floating Life Capacity(20oC,at 1.67Vpc)
Dimensions
3.15mm(0.124inch)
6.35mm(0.250inch)
Construction Positive ...... Negative ...... Container ...... ...... Cover Sealant ......
12 Years 10min
15min
30min
1h
71Wpc
55Wpc
32.8Wpc
16.6Wpc
Length
Width
Height
Total Height
151mm(5.94inch)
98mm(3.86inch)
95mm(3.74inch)
101mm(3.98inch)
Approx. Weight
4.0Kg (8.82 lbs)
Internal Resistance
Full charged at 20oC: 0.021 Ohm
Self Discharge
3% of capacity declined per month at (20oC)
Capacity Affected by Temp.(20HR) Charge Voltage(20oC)
0.8mm(0.031inch)
6.35mm(0.250inch)
40oC 109%
20oC
0oC
-15oC
100%
85%
65%
Cycle use 14.4-14.8V(-30mV/ oC), max. Current: 3.9A
Page 1 of 2
Float use 13.6-13.8V(-18mV/ oC)
HR 12-55W
Charge Voltage
(CA) (V/Cell)
(%) 120 100
0.25
o
Constant Charge at 0.25CA-2.40V (20 C) Charge Capacity
Charge Voltage
2.40 80
2.20 100%Discharge
0.20
60
2.00
50%Discharge
0.15
40
0.10 20
1.80
0.05
0
0
Discharge Characteristic (20oC)
Charge Characteristic
Charge Current
0
2
4
6
8
10
Discharge Voltage (V/Cell)
Current
Charge
Charge Capacity
High Rate Series SLA Battery
2.17 2.00 1.83 0.25CA
1.67 3CA
1.50
0
12
2
6
2.25
110 105
2.17
100 95 90
Capacity (%)
Battery Voltage (V/Cell)
30
0.6CA
60
3
10 Hour
20
Self Discharge Characteristics
Relationship of OCV and state of charge
2.00
12
1CA
Min
Time(hour)
2.08
2CA
0.1CA 0.05CA
85 80 75 70 65 60 55 50
1.92
1.83
45
0
10
20
30
40
50
60
70
80
90
100
40 0
o
1
2
20oC
o
40 C
30 C 3 4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20
Storage time:months
Remained Capacity(%)
Constant current discharge ratings-amperes at 20oC
F .V /Tim e 1.6 0 V 1.6 7 V 1.7 0 V 1.7 5 V 1.8 0 V 1.8 5 V
5m in 65 .0 61 .0 55 .9 54 .8 49 .0 43 .3
10 m in 40 .4 38 .4 37 .0 35 .8 34 .2 32 .6
1 5m in 3 0.5 2 9.3 2 8.7 2 7.7 2 5.2 2 2.6
3 0m in 1 8 .6 1 7 .8 1 6 .2 1 5 .4 1 4 .2 1 3 .1
4 5 m in 1 2 .4 1 2 .0 1 1 .3 1 0 .7 1 0 .0 9 .26
1h 9 .2 3 9 .1 1 8 .8 3 8 .4 2 7 .8 8 7 .3 4
1 .5h 6.6 4 6.5 0 6.2 3 5.9 6 5.6 3 5.3 0
2h 5.3 5 5.2 0 4.9 3 4.7 4 4.5 0 4.2 8
3h 4 .05 3 .90 3 .64 3 .51 3 .38 3 .26
4 5 m in 2 2 .3 2 2 .0 2 1 .1 2 0 .6 1 9 .5 1 8 .3
1h 16 .7 16 .6 16 .2 16 .0 15 .0 14 .1
1 .5h 4.4 7 4.4 1 4.2 9 4.2 1 4.0 0 3.8 0
2h 9 .5 5 9 .3 6 9 .0 5 8 .8 6 8 .4 9 8 .1 2
3h 7 .19 6 .96 6 .65 6 .49 6 .30 6 .11
Constant power discharge ratings-watts at 20oC
F .V /Tim e 1 .6 0 V 1 .6 7 V 1 .7 0 V 1 .7 5 V 1 .8 0 V 1 .8 5 V
5 m in 1 14 1 10 1 04 99 .6 95 .4 86 .5
10 m in 7 3.0 7 1.2 7 0.5 7 0.0 6 9.2 6 5.7
1 5m in 5 5.7 5 5.0 5 4.5 5 4.1 5 0.1 4 5.5
3 0m in 3 3 .5 3 2 .8 3 0 .7 2 9 .8 2 8 .4 2 6 .6
ISO9001
COPYRIGHT BSB POWER COMPANY LIMITED Page 2 of 2
(Updated: 1-Nov-2010)