HR 12-88W High Rate Series SLA Battery RANGE SUMMARY By combining proprietary high rate plate design with low internal resistance AGM separators, BSB created the innovative High Rate range of batteries. This range offers extremely high power output at 15 minutes backup time with 12 years design life and is highly suited to high rate UPS and power switchgear applications. Application Alarm System Cable Televison Communication Equipment Control Equipment Security System Medical Equipment Toys UPS Emergency Power System General Features 14mm(0.55inch) Construction Lead dioxide Lead ABS ABS Epoxy Resin Safety valve Terminal Separator Electrolyte ...... ...... ...... ...... EPDR Copper AGM Sulfuric acid Terminal Dimensions 167mm(6.57inch) Positive ...... Negative ...... Container ...... ...... Cover Sealant ...... 2mm(0.08inch) 5.5mm(0.22inch) 12mm(0.39inch) 5mm(0.20inch) · Sealed and maintenance free operation. · Non-Spillable construction design. · ABS containers and covers(UL94 V0, optional). · Safety valve installation for explosion proof. · High quality and high reliability. · Exceptional deep discharge recovery performance. · Low self discharge characteristic. · Flexible design for multiple installation positions. 76mm(2.99inch) 181mm(7.13inch) HR12-88W (88W to 1.67V, 15min) Battery Model Designed Floating Life Capacity(20oC) 12 Years 20HR(1.1A,1.80V) 22AH Dimensions 10HR(2.20A,1.80V) 5HR(3.93A,1.75V) 1HR(15.6A,1.60V) 22.0AH 19.7AH 15.6AH Length Width Height Total Height 181mm(7.13inch) 76mm(2.99inch) 167mm(6.57inch) 167mm(6.57inch) Approx. Weight 6.2Kg (13.7 lbs) Internal Resistance Full charged at 20oC: 0.0088 Ohm Self Discharge 3% of capacity declined per month at (20oC) Capacity Affected by Temp.(20HR) Charge Voltage(20oC) 40oC 102% 20oC 0oC 100% 85% Cycle use 14.4-14.8V(-30mV/ oC), max. Current: 6.6A Page 1 of 2 -15oC 65% Float use 13.6-13.8V(-20mV/ oC) HR 12-88W Charge Voltage Constant Charge At 0.25CA-2.30V (20 C) (CA) (V/Cell) 80 0.25 Charge Capacity Charge Voltage 100 2.17 100%Discharge 0.20 60 2.00 50%Discharge 0.15 40 0.10 20 1.83 0.05 0 0 Charge Current 0 2 4 6 8 10 2.17 2.00 1.83 0.25CA 0.1CA 0.05CA 1.67 1.60 3CA 2CA 1CA 6 12 30 0.6CA 1.33 0 12 2 60 3 Min Time(hour) 10 Hour 20 Self Discharge Characteristics Relationship of OCV and state of charge 110 105 2.25 2.17 Capacity (%) Battery Voltage (V/Cell) (20 C) o 120 2.33 o Discharge Characteristic Charge Characteristic Discharge Voltage (V/Cell) (%) Current Charge Charge Capacity High Rate Series SLA Battery 2.08 2.00 100 95 90 85 80 75 70 65 60 55 50 1.92 o 0 10 20 30 40 50 60 70 80 90 100 40 0 1 2 20oC o 40 C 45 1.83 30 C 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Storage time:months Remained Capacity(%) Constant current discharge ratings-amperes at 20oC F . V/Time 5MIN 10MIN 15MIN 30MIN 1HR 3HR 5HR 10HR 20HR 1. 60V 104 64. 7 48. 8 29. 8 15. 6 6. 86 4. 19 2. 28 1. 29 1. 67V 97. 6 61. 4 47. 0 28. 5 15. 4 6. 60 4. 11 2. 26 1. 25 1. 70V 89. 4 59. 2 45. 8 25. 9 15. 0 6. 16 4. 02 2. 25 1. 23 1. 75V 87. 7 57. 3 44. 4 24. 6 14. 3 5. 95 3. 93 2. 25 1. 19 1. 80V 78. 4 54. 7 40. 3 22. 8 13. 3 5. 72 3. 70 2. 20 1. 16 1. 85V 69. 2 52. 1 36. 2 21. 0 12. 4 5. 51 3. 46 2. 17 1. 13 Constant power discharge ratings-watts at 20oC F. V/Time 5MIN 10MIN 15MIN 30MIN 1HR 3HR 5HR 10HR 20HR 1. 60V 182 117 89. 1 53. 6 29. 5 12. 7 7. 41 4. 91 2. 58 1. 67V 176 114 88. 0 52. 5 29. 3 12. 3 7. 38 4. 88 2. 48 1. 70V 166 113 87. 3 49. 2 28. 8 11. 8 7. 28 4. 85 2. 45 1. 75V 167 112 86. 5 47. 7 28. 3 11. 5 7. 22 4. 78 2. 39 1. 80V 153 111 80. 2 45. 5 26. 6 11. 2 7. 00 4. 72 2. 33 1. 85V 138 105 72. 8 42. 6 25. 1 10. 8 6. 77 4. 66 2. 24 ISO9001 COPYRIGHT BSB POWER COMPANY LIMITED Page 2 of 2