Transcript
HR 12-88W High Rate Series SLA Battery RANGE SUMMARY By combining proprietary high rate plate design with low internal resistance AGM separators, BSB created the innovative High Rate range of batteries. This range offers extremely high power output at 15 minutes backup time with 12 years design life and is highly suited to high rate UPS and power switchgear applications.
Application Alarm System Cable Televison Communication Equipment Control Equipment
Security System Medical Equipment Toys UPS Emergency Power System
General Features
14mm(0.55inch)
Construction Lead dioxide Lead ABS ABS Epoxy Resin
Safety valve Terminal Separator Electrolyte
...... ...... ...... ......
EPDR Copper AGM Sulfuric acid
Terminal Dimensions
167mm(6.57inch)
Positive ...... Negative ...... Container ...... ...... Cover Sealant ......
2mm(0.08inch)
5.5mm(0.22inch)
12mm(0.39inch)
5mm(0.20inch)
· Sealed and maintenance free operation. · Non-Spillable construction design. · ABS containers and covers(UL94 V0, optional). · Safety valve installation for explosion proof. · High quality and high reliability. · Exceptional deep discharge recovery performance. · Low self discharge characteristic. · Flexible design for multiple installation positions.
76mm(2.99inch)
181mm(7.13inch)
HR12-88W (88W to 1.67V, 15min)
Battery Model Designed Floating Life Capacity(20oC)
12 Years 20HR(1.1A,1.80V) 22AH
Dimensions
10HR(2.20A,1.80V)
5HR(3.93A,1.75V)
1HR(15.6A,1.60V)
22.0AH
19.7AH
15.6AH
Length
Width
Height
Total Height
181mm(7.13inch)
76mm(2.99inch)
167mm(6.57inch)
167mm(6.57inch)
Approx. Weight
6.2Kg (13.7 lbs)
Internal Resistance
Full charged at 20oC: 0.0088 Ohm
Self Discharge
3% of capacity declined per month at (20oC)
Capacity Affected by Temp.(20HR) Charge Voltage(20oC)
40oC 102%
20oC
0oC
100%
85%
Cycle use 14.4-14.8V(-30mV/ oC), max. Current: 6.6A
Page 1 of 2
-15oC 65% Float use 13.6-13.8V(-20mV/ oC)
HR 12-88W
Charge Voltage
Constant Charge At 0.25CA-2.30V (20 C)
(CA) (V/Cell)
80
0.25
Charge Capacity
Charge Voltage
100 2.17
100%Discharge
0.20
60
2.00
50%Discharge
0.15
40
0.10 20
1.83
0.05
0
0
Charge Current
0
2
4
6
8
10
2.17 2.00 1.83 0.25CA 0.1CA 0.05CA
1.67 1.60
3CA
2CA
1CA
6
12
30
0.6CA
1.33 0
12
2
60
3
Min
Time(hour)
10 Hour
20
Self Discharge Characteristics
Relationship of OCV and state of charge 110 105
2.25
2.17
Capacity (%)
Battery Voltage (V/Cell)
(20 C)
o
120 2.33
o
Discharge Characteristic
Charge Characteristic Discharge Voltage (V/Cell)
(%)
Current
Charge
Charge Capacity
High Rate Series SLA Battery
2.08
2.00
100 95 90 85 80 75 70 65 60 55 50
1.92
o
0
10
20
30
40
50
60
70
80
90
100
40
0
1
2
20oC
o
40 C
45
1.83
30 C 3
4
5
6
7 8
9 10 11 12 13 14 15 16 17 18 19 20
Storage time:months
Remained Capacity(%)
Constant current discharge ratings-amperes at 20oC F . V/Time
5MIN
10MIN
15MIN
30MIN
1HR
3HR
5HR
10HR
20HR
1. 60V
104
64. 7
48. 8
29. 8
15. 6
6. 86
4. 19
2. 28
1. 29
1. 67V
97. 6
61. 4
47. 0
28. 5
15. 4
6. 60
4. 11
2. 26
1. 25
1. 70V
89. 4
59. 2
45. 8
25. 9
15. 0
6. 16
4. 02
2. 25
1. 23
1. 75V
87. 7
57. 3
44. 4
24. 6
14. 3
5. 95
3. 93
2. 25
1. 19
1. 80V
78. 4
54. 7
40. 3
22. 8
13. 3
5. 72
3. 70
2. 20
1. 16
1. 85V
69. 2
52. 1
36. 2
21. 0
12. 4
5. 51
3. 46
2. 17
1. 13
Constant power discharge ratings-watts at 20oC F. V/Time
5MIN
10MIN
15MIN
30MIN
1HR
3HR
5HR
10HR
20HR
1. 60V
182
117
89. 1
53. 6
29. 5
12. 7
7. 41
4. 91
2. 58
1. 67V
176
114
88. 0
52. 5
29. 3
12. 3
7. 38
4. 88
2. 48
1. 70V
166
113
87. 3
49. 2
28. 8
11. 8
7. 28
4. 85
2. 45
1. 75V
167
112
86. 5
47. 7
28. 3
11. 5
7. 22
4. 78
2. 39
1. 80V
153
111
80. 2
45. 5
26. 6
11. 2
7. 00
4. 72
2. 33
1. 85V
138
105
72. 8
42. 6
25. 1
10. 8
6. 77
4. 66
2. 24
ISO9001
COPYRIGHT BSB POWER COMPANY LIMITED Page 2 of 2