Valve Regulated Lead-Acid Rechargeable Battery HR50-12 (200W/Cell 15Min Rate) For High Rate Discharge The battery is constructed by plates, separators, safety valves and container. Since the electrolyte is held by a glass-mat separator and plates, the battery can be used in any direction and position without leakage. PERFORMANCE SPECIFICATIONS Nominal Voltage(V).........................................................................................12 volts(6cells in series) Nominal Capacity(Ah) 10 Hour rate F.V.(1.75V/cell) (4.80A to 10.50volts)..................................................................48.0Ah 15 Min rate F.V.(1.30V/cell) (1200W to 7.80volts) ...................................................................25.0Ah Approximate Weight ................................................................................................15.3Kg(33.74lbs.) Terminal Standard.............................................................................................................................Type B2 Optional...........................................................................................................................Type I1, I2 Internal Resistance (Fully Charged Battery).................................................................................<5m Maximum Discharge Current For 5 sec.(A)....................................................................................600A Maximum Charge Current(A)......................................................................................................14.4A Ambient Temperature Charge........................................................................................................0 OC(32 OF)~40 OC(104 OF) Discharge..................................................................................................-20 OC(-4 OF)~50 OC(122 OF) storage......................................................................................................-20 OC(-4 OF)~40 OC(104 OF) Vibration test: Frequency: 16.7HZ Amplitude: 4mm vibrate the battery horizontally or vertically for 60 minutes. The battery have no abnormality. Case............................................................................................................................................ABS Dimension(mm/inch) Length 1.5mm.....................................................................................................197/7.76 Width 1.5mm.....................................................................................................165/6.50 Container Height 1.5mm.....................................................................................................171/6.73 Total Height 1.5mm.....................................................................................................171/6.73 Application.............................................................................................UPS, Wheelchairs, Golf-Carts. HR50-12 Battery discharge characteristics (25 OC/77 OF) Battery Charging Characteristics (Typical example of the charge characteristic for the standby use) 15.0 12.0 120 0.18 14.0 11.0 100 0.15 13.0 8.16A 4.8A 12A 10.0 28.8A 9.0 8.0 240A 192A 144A 96A 7.0 1 2 3 5 10 80 60 40 0.12 0.09 0.06 20 0.03 0 0 Charge voltage(V) 0.21 Charge current(CA) 140 Charge volume(%) Terminal voltage(V) 13.0 Charge voltage C ha rg e 12.0 11.0 10.0 48A 20 30 vo lu m e 1 Discharge 100 %(0.1CAx 10h) 50 %(0.1CAx 5h) 2 Constant voltage charging Charge voltage:2.275V/cell Charge current:0.1CA O O 3 Temperature 20 C(68 F) Charge current 60 3 10 5 0 20 0 10 5 20 25 Charge time (hr) Hr Min 15 DISCHARGE TIME Effect of Temperature on Long Term Float Life 10 Charging Procedure Charging method Constant For standby voltage & power Source Constant current charging For (with current cycle service restriction) Temperature compensation coefficient of charging voltage o (mV/C /cell) 2.25~2.30 Max. charging current (CA) -3 2.40~2.50 100% discharge 50% discharge 24 0.3 -4 Charging time o 0.1CA, 20C (h) 0.3 20 16 6 5 Life expectancy(year) Application Charging Voltage o at 20C (V/cell) 8 Charging voltage : 2.275V/cell 4 3 2 1 10 0.5 20 68 30 86 40 104 50 122 o C F o Battery temperature OUTER DIMENSIONS TERMINAL TYPE Constant power discharge characteristics at 25OC/77 OF mm(inch) Terminal B2 Terminal I1 5.5(0.22) 17.0(0.67) 7.5(0.30) 5.2(0.20) [M5 BOLT & NUT] 197 1.5(7.76 0.06) 2.0(0.08) Discharge time 15.0(0.59) M5 Final Voltage 5Min 10Min 15Min 20Min 30Min 40Min 50Min 60Min Battery output power(W) [M5 BOLT & NUT] 10.80V 2050 1400 1014 865 658 500 418 368 10.20V 2450 1563 1103 916 685 519 431 376 9.60V 2625 1644 1153 950 700 531 440 383 9.00V 2700 1675 1178 965 709 538 445 386 8.40V 2750 1698 1191 974 714 541 449 389 7.80V 2775 1713 1200 980 718 544 451 390 Terminal I2 165 1.5(6.50 0.06) USA: B&B BATTERY(USA) INC. 6415 RANDOLPH ST.COMMERCE, CA,90040 U.S.A. TEL:1-323-278-1900.1-800-278-8599 FAX:1-323-278-1268 E-Mail:[email protected] EUROPE: B&B BATTERY(EUROPE) B.V. 3 WIJNGAARDVELD, 9300 AALST,BELGIUM TEL:(00)32-53781567 FAX:(00)32-53781567 E-Mail:[email protected] 2.0(0.08) 171 1.5(6.73 0.06) M6 TERMINAL POSITION [M6 BOLT] RAOPING, GUANG DONG,CHINA,515700 TEL:86-768-7601001-2 FAX:86-768-7601469 E-Mail:[email protected] JAPAN: B&B BATTERY(JAPAN) CO., LTD. 1375-11 NARAHARA-MACHI,HACHIOJI, TOKYO 193-0803,JAPAN. TEL:81-426-25-6375 FAX:81-426-25-6375 E-Mail:[email protected] HONG KONG: NATIONAL TRADING LTD. TEL:852-2301-3800 FAX:852-2739-1182 E-Mail:[email protected] TAIWAN: B.B. BATTERY(TAIWAN) CO., LTD. TEL:886-6-502-5150 FAX:886-6-589-8087 E-Mail:[email protected] CHINA FACTORY: All data shall be changed without prior notice, BB reserves the right to explain and update the information contained hereinto. REV. May. 2006