Transcript
ENGLISH
ALPHA PROFILE 1500 ALPHA PROFILE 1500 ST
C61330 C61331
INSTRUCTION MANUAL
INDEX Page Contents 2 4 6 8 10
Safety Information EN Informazioni di sicurezza IT Consignes de sécurité FR Informationen zur Sicherheit Informaciones de suguridad
12
Unpacking and preparation
13
Installation and start-up
14
Control panel
16
Menu setting
25
Maintenance
33
Technical information
33
Cause and solution of problems
34
Channel functions
DE ES
Congratulations on choosing a Clay Paky product! We thank you for your custom. Please note that this product, as all the others in the rich Clay Paky range, has been designed and made with total quality to ensure excellent performance and best meet your expectations and requirements. Carefully read this instruction manual in its entirety and keep it safe for future reference. It is essential to know the information and comply with the instructions given in this manual to ensure the fitting is installed, used and serviced correctly and safely. CLAY PAKY S.p.A. disclaims all liability for damage to the fitting or to other property or persons deriving from installation, use and maintenance that have not been carried out in conformity with this instruction manual, which must always accompany the fitting. CLAY PAKY S.p.A. reserves the right to modify the characteristics stated in this instruction manual at any time and without prior notice.
1
SAFETY INFORMATION
EN
• Installation Make sure all parts for fixing the projector are in a good state of repair. Make sure the point of anchorage is stable before positioning the projector. The safety chain must be properly hooked onto the fitting and secured to the framework, so that, if the primary support system fails, the fitting falls as little as possible. If the safety chain gets used, it needs to be replaced with a genuine spare.
1500W
• Minimum distance of illuminated objects The projector needs to be positioned so that the objects hit by the beam of light are at least 5 metres (16'5'') from the lens of the projector.
5
• Minimum distance from flammable materials The projector must be positioned so that any flammable materials are at least 0.20 metres (8") from every point on the surface of the fitting.
ta 40°C IP20
• Maximum ambient temperature Do not operate the fixture if the ambient temperature (Ta) exceeds 40° C (104° F). • IP20 protection rating The fitting is protected against penetration by solid bodies of over 12mm (0.47”) in diameter (first digit 2), but not against dripping water, rain, splashes or jets of water (second digit 0). • Protection against electrical shock Connection must be made to a power supply system fitted with efficient earthing (Class I appliance according to standard EN 60598-1). It is, moreover, recommended to protect the supply lines of the projectors from indirect contact and/or shorting to earth by using appropriately sized residual current devices. • Connection to mains supply Connection to the electricity mains must be carried out by a qualified electrical installer. Check that the mains frequency and voltage correspond to those for which the projector is designed as given on the electrical data label. This label also gives the input power to which you need to refer to evaluate the maximum number of fittings to connect to the electricity line, in order to avoid overloading. IMPORTANT: to prevent EMI disturbances, in some condition it might be necessary to clip around the DMX and the Ethernet cable, as close as possible to the projector, an appropriate ferrite bead. Shielded cables must always be used.
tc 150°C
• Temperature of the external surface The maximum temperature that can be reached on the external surface of the fitting, in a thermally steady state, is 150°C (302°F). • Maintenance Before starting any maintenance work or cleaning the projector, cut off power from the mains supply. After switching off, do not remove any parts of the fitting for at least 10 minutes. After this time the likelihood of the lamp exploding is virtually nill. If it is necessary to replace the lamp, wait for another 20 minutes to avoid getting burnt. The fitting is designed to hold in any splinters produced by a lamp exploding. The lenses must be mounted and, if visibly damaged, they have to be replaced with genuine spares. • Lamp The fitting mounts a high-pressure lamp that needs an external igniter. This igniter is fitted onto the apparatus. - Carefully read the "operating instructions" provided by the lamp manufacturer. - Immediately replace the lamp if damaged or deformed by heat.
Risk Group 2 According to EN 62471
• Photobiological Safety CAUTION. Possibly hazardous optical radiation emitted from this product. Do not stare at operating lamp. May be harmful to the eyes.
This product is intended for the following areas of application: studios, stages, theaters, exhibitions, trade fairs, events, theme parks, entertainment venues, architectural lighting and similar ALPHA PROFILE 1500 & ST
2
Not suitable for household illumination
Not for residential use
LiFePO4 Pb
• Battery This product contains a rechargeable lead-acid or lithium iron tetraphosphate battery. To preserve the environment, please dispose the battery at the end of its life according to the regulation in force.
Disposing This product is supplied in compliance with European Directive 2012/19/EU - Waste Electrical and Electronic Equipment (WEEE). To preserve the environment please dispose/recycle this product at the end of its life according to the local regulation.
The products to which this manual refers comply with the European Directives pursuant to: • 2006/95/EC - Safety of electrical equipment supplied at low voltage (LVD) • 2004/108/EC - Electromagnetic Compatibility (EMC) • 2011/65/EU - Restriction of the use of certain hazardous substances (RoHS) • 2009/125/EC - EcoDesign requirements for Energy-related Products (ErP)
ALPHA PROFILE 1500 & ST
3
IT
INFORMAZIONI DI SICUREZZA
• Installazione Assicurarsi che tutte le parti per il fissaggio del proiettore siano in buona condizione. Assicurarsi della stabilità del punto di ancoraggio prima di posizionare il proiettore. La fune di sicurezza, debitamente agganciata all’apparecchio e fissata alla struttura di sostegno, deve essere installata in modo che, in caso di cedimento del sistema di supporto primario, si abbia la minor caduta possibile dell’apparecchio. Dopo un eventuale intervento la fune di sicurezza deve essere sostituita con il ricambio originale.
1500W
• Distanza minima degli oggetti illuminati Il proiettore deve essere posizionato in modo tale che gli oggetti colpiti dal fascio luminoso siano distanti almeno 5 metri dall’obiettivo del proiettore stesso.
5
• Distanza minima dei materiali infiammabili Il proiettore deve essere posizionato in modo tale che i materiali infiammabili siano distanti almeno 0,20 metri da ogni punto della superficie dell’apparecchio.
ta 40°C IP20
• Massima temperatura ambiente Non utilizzare il proiettiore se la temperatura ambiente (Ta) supera i 40°C. • Grado di protezione IP20 L’apparecchio è protetto contro la penetrazione di corpi solidi di dimensione superiore a 12mm (prima cifra 2), mentre teme lo stillicidio, la pioggia, gli spruzzi e i getti d’acqua (seconda cifra 0). • Protezione contro la scossa elettrica È obbligatorio effettuare il collegamento ad un impianto di alimentazione dotato di un’efficiente messa a terra (apparecchio di Classe I secondo la norma EN 60598-1). Si raccomanda, inoltre, di proteggere le linee di alimentazione dei proiettori dai contatti indiretti e/o cortocircuiti verso massa tramite l’uso di interruttori differenziali opportunamente dimensionati. • Collegamento alla rete di alimentazione Le operazioni di collegamento alla rete di distribuzione dell’energia elettrica devono essere effettuate da un installatore elettrico qualificato. Verificare che frequenza e tensione della rete corrispondano alla frequenza ed alla tensione per cui il proiettore è predisposto ed indicate sulla targhetta dei dati elettrici. Sulla medesima targhetta è pure indicata la potenza assorbita. Fare riferimento a quest’ultima per valutare il numero massimo di apparecchi da collegare alla linea elettrica, al fine di evitare sovraccarichi. IMPORTANTE: per evitare l'insorgere di interferenze elettromagnetiche, in alcune situazioni può rendersi necessario avvolgere attorno al cavo DMX ed al cavo Ethernet, il più possibile vicino al proiettore, una ferrite appropriata. Usare sempre cavi schermati.
tc 150°C
• Temperatura della superficie esterna La temperatura massima raggiungibile sulla superficie esterna dell’apparecchio, in condizioni di regime termico, è di 150°C. • Manutenzione Prima di iniziare qualsiasi operazione di manutenzione o pulizia sul proiettore togliere la tensione dalla rete di alimentazione. Dopo lo spegnimento non rimuovere alcuna parte dell’apparecchio per 10 minuti. Trascorso tale tempo la probabilità di esplosione della lampada è praticamente nulla. Se è necessario sostituire la lampada, aspettare ulteriori 20 minuti per evitare scottature. L’apparecchio è progettato in modo da trattenere le schegge prodotte dall’eventuale scoppio della lampada. Le lenti devono essere obbligatoriamente montate; devono inoltre, se visibilmente danneggiate, essere sostituite con ricambi originali. • Lampada L’apparecchio monta una lampada ad alta pressione che richiede un accenditore esterno. Tale accenditore è incorporato nell’apparecchio. - Leggere attentamente le “istruzioni d’uso” fornite dal costruttore della lampada. - Sostituire immediatamente la lampada se danneggiata o deformata dal calore.
Gruppo di rischio 2 Secondo la norma EN 62471
ALPHA PROFILE 1500 & ST
• Sicurezza fotobiologica ATTENZIONE: Possibile radiazione ottica rischiosa emessa da questo prodotto. Non fissare la lampada in funzione. Può essere pericoloso per gli occhi.
4
Il prodotto è concepito per essere utilizzato nei seguenti ambiti: studi, palchi, teatri, esposizioni, fiere, eventi, parchi a tema, locali di intrattenimento, illuminazione architetturale e simili
Non adatto all'illuminazione domestica
Non per uso residenziale
LiFePO4 Pb
• Batteria Questo prodotto contiene una batteria ricaricabile piombo-acido o Litio Ferro Tetrafosfato. A tutela dell'ambiente si prega di smaltire la batteria a fine vita in conformità alla normativa vigente.
Smaltimento Questo dispositivo è conforme alla Direttiva Europea 2012/19/UE - Rifiuti di apparecchiature elettriche ed elettroniche (RAEE). Nel rispetto dell'ambiente, smaltire/riciclare il prodotto al termine del suo ciclo di vita secondo le disposizioni di legge locali.
I prodotti a cui questo manuale si riferisce sono conformi alle Direttive Europee di cui sono oggetto: • 2006/95/CE - Sicurezza delle apparecchiature alimentate in Bassa Tensione (LVD) • 2004/108/CE - Compatibilità Elettromagnetica (EMC) • 2011/65/UE - Restrizione d’uso di determinate sostanze pericolose (RoHS) • 2009/125/CE - Specifiche per la progettazione ecocompatibile dei prodotti connessi all’energia (ErP)
ALPHA PROFILE 1500 & ST
5
FR
CONSIGNES DE SÉCURITÉ
• Installation S’assurer que toutes les pièces pour la fixation du projecteur sont en bon état. S’assurer de la stabilité du point d’ancrage avant de positionner le projecteur. Le câble de sécurité, à fixer correctement à l’appareil et à la structure de support, doit être installé de façon à ce que, en cas de rupture du système de support principal, la chute de l’appareil soit la plus limitée possible. Après une éventuelle intervention du câble de sécurité suite à une chute, il faut le remplacer par une pièce de rechange d’origine.
1500W
• Distance minimum des objets éclairés Le projecteur doit être positionné de façon à ce que les objets éclairés par le faisceau lumineux soient à une distance d’au moins 5 mètres de l’objectif du projecteur.
5
• Distance minimum des substances inflammables Le projecteur doit être positionné de façon à ce qu’il y ait une distance d’au moins 0,20 mètre entre toute substance inflammable et tout point de sa surface.
ta 40°C IP20
• Température ambiante maximum Ne pas utiliser le projecteur quand la température ambiante (Ta) dépasse 40°C. • Degré de protection IP20 L’appareil est protégé contre la pénétration de corps solides de dimension supérieure à 12 mm (premier chiffre 2), tandis qu’il craint les gouttes d’eau, la pluie et les projections d’eau (deuxième chiffre 0). • Protection contre l’électrisation L’appareil doit obligatoirement être branché à une installation d’alimentation équipée d’une mise à la terre efficace (appareil de Classe I selon la norme EN 60598-1). Nous recommandons également de protéger les lignes d’alimentation des projecteurs contre les contacts indirects et/ou les courts-circuits vers la masse en utilisant des interrupteurs différentiels de sensibilité adéquate. • Branchement au réseau d’alimentation Les opérations de branchement au réseau de distribution de l’énergie électrique doivent être exécutées par un installateur électrique qualifié. Contrôler que la fréquence et la tension de réseau correspondent à la fréquence et à la tension pour lesquelles le projecteur est prévu ; ces données sont indiquées sur la plaquette des données électriques. Cette même plaquette reporte également la puissance absorbée. Afin d’éviter des surcharges, se référer à celle-ci pour évaluer le nombre maximum d’appareils à brancher à la ligne électrique. IMPORTANT : afin d’empêcher l’apparition de perturbations électromagnétiques, il peut s’avérer nécessaire dans certains cas d'accrocher autour du DMX et du câble Ethernet, le plus près possible du projecteur, un manchon de ferrite approprié. Toujours utiliser des câbles blindés.
tc 150°C
• Température de la surface extérieure La température maximum qui peut être atteinte sur la surface extérieure de l’appareil, en conditions de régime thermique, est de 150°C. • Entretien Avant de procéder à toute opération d’entretien ou de nettoyage sur le projecteur, couper la tension d’alimentation. Après avoir éteint le projecteur, ne démonter aucun élément de l’appareil pendant les 10 minutes qui suivent. Une fois ce temps écoulé, la probabilité d’explosion de la lampe est quasiment nulle. S’il faut remplacer la lampe, attendre encore 20 minutes afin d’éviter tout risque de brûlures. L’appareil a été conçu de façon à retenir les éclats produits en cas d’explosion de la lampe. Les lentilles doivent obligatoirement être montées sur l’appareil et doivent être remplacées par des pièces d’origine dès qu’elles sont visiblement endommagées. • Lampe L’appareil fonctionne avec une lampe haute pression avec ballast externe. Ce dernier est incorporé dans l’appareil. - Lire avec attention les « instructions d’utilisation » fournies par le fabricant de la lampe. - Remplacer la lampe dès qu’elle est endommagée ou déformée par la chaleur
Classe de dangerosité 2 Selon la norme EN 62471 ALPHA PROFILE 1500 & ST
• Sécurité photobiologique ATTENTION : Possible radiation optique émise par ce produit. Ne pas fixer la lampe lorsqu’elle est allumée. Peut être dangereux pour les yeux.
6
Le produit est conçu pour être utilisé dans les milieux suivants : studios, scènes, théâtres, expositions, salons, événements, parcs à thème, lieux de divertissement, éclairage architectural et similaires
Non adapté à l’éclairage domestique
Non indiqué pour un utilization résidentiel
LiFePO4 Pb
• Batterie Ce produit contient une batterie rechargeable au plomb-acide ou tétraphosphate de fer au lithium. Une fois la batterie arrivée à la fin de sa durée de vie, procéder à son élimination conformément à la norme en vigueur de manière à éviter toute pollution.
Élimination Ce dispositif est conforme à la Directive Européenne 2012/19/UE – Déchets d’équipements électriques et électroniques (DEEE). Dans le respect de l’environnement, écouler/recycler le produit à la fin de son cycle de vie selon les dispositions légales locales.
The products to which this manual refers comply with the European Directives pursuant to: • 2006/95/EC - Safety of electrical equipment supplied at low voltage (LVD) • 2004/108/EC - Electromagnetic Compatibility (EMC) • 2011/65/EU - Restriction of the use of certain hazardous substances (RoHS) • 2009/125/EC - EcoDesign requirements for Energy-related Products (ErP)
ALPHA PROFILE 1500 & ST
7
DE
INFORMATIONEN ZUR SICHERHEIT
• Installation Sicherstellen, dass alle Teile für die Befestigung des Projektors in einwandfreiem Zustand sind. Vor der Installation des Projektors die Stabilität der Verankerungsstelle überprüfen. Das korrekt am Gerät eingehakte und an der Haltestruktur befestigte Sicherheitsseil muss so installiert werden, dass bei einem Nachgeben der Haupthalterung die Fallhöhe des Gerätes so gering wie möglich ist. Nach einem eventuellen Einsatz muss das Sicherheitsseil durch ein Originalersatzteil ersetzt werden.
1500W
• Mindestabstand zu beleuchteten Objekten Der Projektor muss so installiert werden, dass der Abstand zwischen den vom Lichtstrahl beleuchteten Objekten und dem Objektiv des Projektors mindestens 5 Meter beträgt.
5
• Mindestabstand zu entzündbaren Materialien Der Projektor muss so installiert werden, dass entzündbare Materialien mindestens 0,20 Meter von jedem Punkt der Geräteoberfläche entfernt sind.
ta 40°C
IP20
• Max. Raumtemperatur Den Projektor nicht verwenden, wenn die Raumtemperatur (RT) 40°C überschreitet. • Schutzart IP20 Das Gerät ist gegen das Eindringen von festen Fremdkörpern mit Durchmesser über 12 mm (erste Kennziffer 2) geschützt, während es gegen Tropf,- Regen- und Spritzwasser sowie Wasserstrahlen (zweite Kennziffer 0) empfindlich ist. • Schutz gegen Stromschlag Es ist Pflicht, das Gerät an eine Stromversorgungsanlage anzuschließen, die mit einer leistungsfähigen Erdung ausgestattet ist (Gerät der Klasse I gemäß Richtlinie EN 60598-1). Darüber hinaus wird empfohlen, die Zuleitungen der Projektoren mit korrekt bemessenen Fehlerstromschutzschaltern vor indirekten Kontakten und/oder Kurzschlüssen zu schützen. • Netzanschluss Der Anschluss an das Stromnetz muss von einem kompetenten Elektroinstallateur ausgeführt werden. Vergewissern Sie sich, dass Spannung und Frequenz der Netzversorgung mit den Werten übereinstimmen, für die der Projektor ausgelegt ist und die auf dem Typenschild angegeben sind. Ebenfalls auf dem Typenschild ist die Leistungsaufnahme angegeben. Um zu beurteilen, wie viele Geräte maximal an die Stromleitung angeschlossen werden können, ist auf diese Angaben Bezug zu nehmen, damit Überlastungen vermieden werden. WICHTIG: Um das Auftreten von EMI-Störungen zu vermeiden, kann es in einigen Situationen notwendig werden, möglichst nahe am Scheinwerfer um die DMX und das Ethernet-Kabel eine geeignete Ferritperle anzubringen. Immer abgeschirmte Kabel verwenden.
tc 150°C
• Temperatur der Außenfläche Die Außenfläche des Geräts kann im Wärmebetrieb eine Höchsttemperatur von 150°C erreichen. • Wartung Vor Beginn von Wartungs- oder Reinigungsarbeiten am Projektor stets die Stromversorgung abschalten. Nach dem Abschalten 10 Minuten lang keine Geräteteile abnehmen. Nach Ablauf dieser Zeit besteht praktisch keine Gefahr mehr, dass die Lampe birst. Falls die Lampe ersetzt werden muss, weitere 20 Minuten warten, um Verbrennungsgefahr zu vermeiden. Das Gerät wurde so konzipiert, dass es die Splitter bei einem eventuellen Bersten der Lampe zurückhält. Die Montage der Linsen ist obligatorisch vorgeschrieben; des Weiteren müssen sie bei sichtbarer Beschädigung durch Originalersatzteile ersetzt werden. • Lampe Das Gerät ist mit einer Hochdrucklampe bestückt, die eine externe Zündeinheit verlangt. Diese Zündeinheit ist in das Gerät eingebaut. - Lesen Sie die vom Lampenhersteller gelieferte "Bedienungsanleitung" aufmerksam durch. - Eine beschädigte oder von der Hitze verformte Lampe muss sofort ersetzt werden.
Gefahrenklasse 2 Gemäß Norm EN 62471
ALPHA PROFILE 1500 & ST
• Photobiologische Sicherheit ACHTUNG: Mögliche riskante optische Strahlung wird von diesem Produkt abgegeben. Nicht die Lampe fixieren, wenn sie in Betrieb ist. Kann für die Augen gefährlich sein.
8
Das Produkt wurde für die Verwendung in den folgenden Bereichen entwickelt: Studios, Bühnen, Theater, Ausstellungen, Messen, Veranstaltungen, Themenparks, Unterhaltungslokale, Architekturbeleuchtung oder ähnliches
Nicht für Haushaltsbeleuchtung geeignet
Nicht für den häuslichen Gebrauch
LiFePO4 Pb
• Batterie Dieses Produkt enthält eine wiederaufladbare Blei-Säure-Batterie oder Lithium-Eisen-tetraphosphat. Zum Schutz der Umwelt bitten wir Sie, diese Batterie, nachdem sie verbraucht ist, gemäß den geltenden Vorschriften zu entsorgen.
Entsorgung Diese Vorrichtung entspricht der Europäischen Richtlinie 2012/19/UE - Abfall von elektrischen und elektronischen Gerätschaften (RAEE). Das Produkt am Ende seines Lebenszyklus unter Berücksichtigung der Umwelt nach den lokalen Gesetzesvorschriften entsorgen/recyceln.
The products to which this manual refers comply with the European Directives pursuant to: • 2006/95/EC - Safety of electrical equipment supplied at low voltage (LVD) • 2004/108/EC - Electromagnetic Compatibility (EMC) • 2011/65/EU - Restriction of the use of certain hazardous substances (RoHS) • 2009/125/EC - EcoDesign requirements for Energy-related Products (ErP)
ALPHA PROFILE 1500 & ST
9
ES
INFORMACIONES DE SEGURIDAD
• Instalación Asegúrese de que todos los elementos de fijación del proyector estén en buenas condiciones. Controle la estabilidad del punto de anclaje antes de instalar el proyector. La cuerda de seguridad, correctamente enganchada al aparato y fijada a la estructura de soporte, debe colocarse de modo que, si el soporte principal cede, el aparato sufra la menor caída posible. En caso de desgaste de la cuerda de seguridad, sustitúyala por el recambio original.
1500W
• Distancia mínima de los objetos iluminados El proyector debe ser posicionado de modo tal que los objetos tocados por el haz luminoso tengan una distancia de al menos 5 metros del objetivo del mismo proyector.
5
• Distancia mínima de los materiales inflamables El proyector debe ser posicionado de modo tal que los materiales inflamables tengan una distancia de al menos 0,20 metros de cada punto de la superficie del aparato.
ta 40°C IP20
• Máxima temperatura ambiente No utilice el proyector si la temperatura ambiente (ta) supera los 40°C. • Grado de protección IP20 El aparato está protegido contra la penetración de cuerpos sólidos de dimensiones superiores a 12 mm (primer dígito 2), pero no contra el goteo, la lluvia, las salpicaduras y los chorros de agua (segundo dígito 0). • Protección contra descargas eléctricas Es obligatorio efectuar la conexión a una instalación de alimentación dotada de una eficiente puesta a tierra (aparato de Clase I según la norma EN 60598-1). Además, se recomienda proteger las líneas de alimentación de los proyectores de los contactos indirectos y/o cortocircuitos hacia masa, mediante el uso de interruptores diferenciales dimensionados oportunamente. • Conexión a la red de alimentación Las operaciones de conexión a la red de distribución de la energía eléctrica deben ser efectuadas por un instalador eléctrico cualificado. Constate que los valores de frecuencia y tensión de la red sean iguales a los que figuran en la placa de los datos eléctricos del proyector. En la misma placa está indicada la potencia absorbida. Hacer referencia a esta última para valorar el número máximo de aparatos que conectar a la línea eléctrica, con el fin de evitar sobrecargas. IMPORTANTE: para evitar que surjan interferencias electromagnéticas, en algunas situaciones puede ser necesario enganchar alrededor de la DMX y al cable Ethernet, lo más cerca posible del proyector, un apropiado manguito de ferrita. Usar siempre cables blindados.
tc 150°C
• Temperatura de la superficie externa La temperatura máxima que puede alcanzar la superficie externa del aparato, en condiciones de régimen térmico, es de 150°C. • Mantenimiento Antes de iniciar cualquier operación de mantenimiento o limpieza del proyector desconecte el aparato de la alimentación eléctrica. Después del apagado no extraiga ninguna parte del aparato durante 10 minutos. Transcurrido dicho tiempo la probabilidad de que la lámpara explote es prácticamente nula. Si fuera necesario cambiar la lámpara, espere 20 minutos más para evitar quemarse. El aparato está proyectado para retener las astillas producidas por el posible estallido de la lámpara. Las lentes deben montarse obligatoriamente; además, si estuvieran dañadas, deberán ser sustituidas por recambios originales. • Lámpara El aparato utiliza una lámpara de alta presión que requiere un arrancador externo. Dicho arrancador está incorporado en el aparato. - Leer atentamente las "instrucciones de uso" suministradas por el fabricante de la lámpara. - Sustituir la lámpara inmediatamente si estuviera dañada o deformada por el calor.
Clase de peligrosidad 2 Según la norma EN 62471
ALPHA PROFILE 1500 & ST
• Seguridad fotobiológica ATENCIÓN: Posible radiación óptica arriesgada emitida por este producto. No fije la lámpara en funcionamiento. Puede ser peligroso para los ojos.
10
El producto es concebido para ser utilizado en los siguientes ambientes: estudios, palcos, teatros, exposiciones, ferias, eventos, parques temáticos locales de entretenimiento, iluminación de arquitecturas y similares
No es apropiado para la iluminación doméstica
No para uso residencial
LiFePO4 Pb
• Batería Este producto contiene una batería recargable plomo-ácido o de litio tetrafosfato Hierro. Para proteger el ambiente se ruega eliminar la batería conforme a la normativa vigente.
Eliminación Este dispositivo es conforme a la Directiva Europea 2012/19/UE - Residuos de equipos eléctricos y electrónicos (RAEE). Con el fin de respetar el ambiente, eliminar/reciclar el producto al final de su ciclo de vida según las disposiciones de ley locales.
The products to which this manual refers comply with the European Directives pursuant to: • 2006/95/EC - Safety of electrical equipment supplied at low voltage (LVD) • 2004/108/EC - Electromagnetic Compatibility (EMC) • 2011/65/EU - Restriction of the use of certain hazardous substances (RoHS) • 2009/125/EC - EcoDesign requirements for Energy-related Products (ErP)
ALPHA PROFILE 1500 & ST
11
UNPACKING AND PREPARATION 1
0 FILE 150 "Q" 0 ALPHA PRO FILE 150 ALPHA PRO
ITALIANO
®
MANUALE
INDICE Contenu
Pag.
to
di sicurezza Informazioni sizione e predispo Disimballo
2 3
e messa Installazione
4
Pannello
5
in funzione
di controllo
ione menu Impostaz
7
Manutenzione
14 22 22 23
Dati tecnici Causa e
soluzione
Funzioni
dei problemi
C61330 C61335
IST00F/001
ZIONI DI ISTRU
Paky! prodotto Clay o che anche scelto un per aver a e La informiam Clay Paky, preferenz Complimenti ricca gamma per mo per la gli altri della della qualità, re La ringrazia come tutti nel segno ni e risponde questo prodotto, o e realizzato prestazio progettat za delle è stato . manuale sempre l’eccellen e ed esigenze garantirLe il presente Sue aspettativ tutte le sue parti ti futuri. La in meglio alle per riferimen ni attentamente accuratamente delle prescrizio rlo Leggere e conserva ed il rispetto li per garantire d’istruzioni delle informazioni essenzia one, uso za ione sono conoscen pubblicaz ni di installazi in questa delle operazio contenute danni za e la sicurezza recchio. bilità per la correttez da dell’appa responsa zione ogni derivanti e manuten S.p.A. declina cose o persone, in conformità non CLAY PAKY o ad altre effettuate , che deve all’apparecchiouso e manutenzione di istruzioni manuale presente installazione, e, in riportato sul chio. modificar con quanto gnare l’apparec la facoltà di tiche si riserva sempre accompa o, le caratteris S.p.A. preavvis . e senza CLAY PAKY e momento manuale di istruzioni qualunqu te nel presente menziona
Lampada 1500W (installata nel proiettore)
2 x 183102/805
canali 1
Packing contents - Fig. 1
2
3 45°
45°
45°
45°
45°
UNLOCKED
45°
LOCKED
LOCKED UNLOCKED 90 ° °
90
°
90
°
90
PAN Mechanism Lock and Release (every 90°) - Fig. 2 TILT Mechanism Lock and Release (every 45°) - Fig. 3
ALPHA PROFILE 1500 & ST
12
INSTALLATION AND START-UP 4
Installing the projector - Fig. 4 The projector can be installed on the floor resting on special rubber feet, on a truss or on the ceiling or wall. WARNING: with the exception of when the projector is positioned on the floor, the safety cable must be fitted. (Cod. 105041/003 available on request). This must be securely fixed to the support structure of the projector and then connected to the fixing point at the centre of the base.
5
1
2 2 1
Connecting and disconnecting power cable - Fig. 5
ALPHA PROFILE 1500 & ST
13
3
CONTROL PANEL 6
Mains
L N
Connecting to the mains supply - Fig. 6
7
DMX 512 5 PIN 5 4
3
1 2
SCREEN SIGNAL SIGNAL
DMX 512 DMX 512 3 PIN SIGNAL
2
SCREEN
1 3
SIGNAL
Connecting to the control signal line (DMX) - Fig. 7 Use a cable conforming to specifications EIA RS-485: 2-pole twisted, shielded, 120Ohm characteristic impedance, 22-24 AWG, low capacity. Do not use microphone cable or other cable with characteristics differing from those specified. The end connections must be made using XLR type 3 or 5-pin male/female connectors. A terminating plug must be inserted into the last projector with a resistance of 120Ohm (minimum 1/4 W) between terminals 2 and 3. IMPORTANT: The wires must not make contact with each other or with the metal casing of the connectors. The casing itself must be connected to the shield braid and to pin 1 of the connectors.
8 Fixture ID
Dmx Address
2
1
MAINS
Warning Message
Switching on the projector - Fig. 8 Press the switch. The projector starts resetting the effects. At the same time, the following information scrolls on the display: Model Alpha PROFILE 1500
Firmware Version X.X.X Date - Hour
xxx (Fixture ID) Dmx Address xxx
System errors E: ......................... W: .........................
On conclusion of resetting in case of absence of dmx signal, Pan and Tilt move to the “Home” position (Pan 50% - Tilt 50%). The control panel (Fig. 8) has a display and buttons for the complete programming and management of the projector menu. The display can be in one of two conditions: rest status and setting status. When it is in the rest status, the display shows the projector’s DMX address and the Fixture ID address (if set). During menu setting status, after a wait time (about 30 seconds) without any key having been pressed, the display automatically returns to rest status. It should be noted than when this condition occurs, any possible value that has been modified but not yet confirmed with the key will be cancelled.
F
ALPHA PROFILE 1500 & ST
14
9
28
28
Reversal of the display - Fig. 9 To activate this function, press UP and DOWN keys simultaneously while the display is in the rest mode. This status will be memorised and maintained even for the next time it will be switched on. To return to the initial state, repeat the operation all over again. Setting the projector starting address On each projector, the starting address must be set for the control signal (addresses from 1 to 512). The address can also be set with the projector switched off. Setting the address: see pag. 8. Setting the projector Fixture ID On each projector, the Fixture ID address must be set for an easy identification of the fixtures in an installation (ID from 1 to 255). The Fixture ID address can be set with the projector switched off. Setting the Fixture ID: see pag. 8.
B
C
Functions of the buttons - Using the menu
F C
Confirms the displayed value, or activates the displayed function, or enters the successive menu.
Decreases the value displayed (with auto-repetitions) or passes to the next item in the menu.
DOWN
B
Increases the value displayed (with auto-repetitions) or passes to the previous item in a menu.
UP
D
Return to the top level
E
Commute from units, tens, hundreds, in the "Address", "Fixture ID" and "Calibration" menù.
LEFT
RIGHT
USING THE MENU: once – “Main Menu” appears on the display. 1) Press 2) Use the UP and DOWN keys to select the menu to be used: • Setup (Setup Menu): To set the setting options. • Option (Option Menu): To set the operating options. • Informations (Informations Menu): To read the counters, software version and other information. • Manual Control (Manual control Menu): To trigger the test and manual control functions. • Test (Test Menu): To check the proper functionning of effects. • Advanced (Advanced Menu): Access to the “Advanced menu” is recommended for a trained technical personnel. To enable the “Advanced” see pag.15 3) Press to display the first item in the selected menu. 4) Use the UP and DOWN keys to select the MENU items.
F
F
B
C
B
C
Setting addresses and options with the projector disconnected The projector’s DMX address, as well as other possible operating options, can also be set when the appliance is disconnected from the electricity supply. All that is needed is to press to momentarily activate the display and thus access the settings. Once the required operations have been carried out, the display will switch off again after a wait time of 30 seconds.
F
ALPHA PROFILE 1500 & ST
15
MENU SETTING
1
2 Set Up
Dmx Address
Channel Mode
3 Option
Lamp Dmx
Pan / Tilt
Information Invert Pan
System Errors
Fixture Hours
Invert Tilt Fixture ID
Lamp Hours
Swap Pan-Tilt
Ethernet Interface
Lamp Strikes
Encoder Pan-Tilt P/T Homing Mode
Option
System Version
Pan Home Def Pos Information
Board diagnostic
Tilt Home Def Pos
Manual Control
Color
Color Mixing
Dmx Monitor
Fixed Wheel Shortcut
Test
Fans Monitor
Macro Color Adjustment Advanced Shutter
Sensor Status
Shutter On Error
Dimmer On Shutter
4
Autofocus Mode Manual Control
Network parameters
Limited Zoom Range Complete Zoom Range
Lamp Macro Effects
Macro group size
Reset Macro fixture Id Channel
Silent Mode
Standard
Quiet Lamp Dimming
5
1500W800W 1500W1200W
Power Mode Test
Pan / Tilt
1500-1200 Full fan speed
6 Advanced
Access code 1234
1200 Low fan speed Colour
Beam
Gobo
1500-1200 Auto fan speed
Upload Firmware
Default Preset
Setup Model
Display
Setting
User Preset 1 User Preset 2 All
ALPHA PROFILE 1500 & ST
UserPreset 3
16
Calibration
NOTE: On grey the default options
Set Up
Dmx Address
SET UP MENU DMX ADDRESS NOTE: without the DMX signal the Address (XXX) flashing Allows you to select the DMX ADDRESS 1) Press - the current DMX Adress appear on the display. keys to plan the DMX Address. 2) Use the UP , DOWN , RIGHT 3) Press to confirm the selection or LEFT to keep current settings.
Address xxx
F B F
Channel Mode
C
E
CHANNEL MODE Allows you to select a channel arrangement from the two available. 1) Press - the current settings appear on the display (Standard or Vector). 2) Use the UP and DOWN keys to select one of the following settings: - Standard - Vector 3) Press to confirm the selection or LEFT to keep current settings.
Standard
F
B
Vector
C
F
Fixture Id
D
FIXTURE ID Allows you to select the FIXTURE ID 1) Press - the current Fixture ID appear on the display. 2) Use the UP , DOWN , RIGHT keys to plan the Fixture ID. 3) Press to confirm the selection or LEFT to keep current settings.
Value xxx
F
F
B
C
E
D
ETHERNET INTERFACE It lets you set the Ethernet settings to be attributed to the projector. 1) Premere . 2) Use the UP and DOWN keys to select the “Ethernet Interface” options to set:
Ethernet Interface
F B
C
Control Protocol It lets you select the “Control Protocol” Art-net to assign according to the control unit used: 1) Press the current setting appears on the display. 2) Use the UP and DOWN keys to select one of the following settings: - Disabled - Art-net on IP 2 - Art-net on IP 10 3) Press to confirm the selection or LEFT to keep the current setting.
Control Protocol
F
B
C
F
D
Repeat on DMX It lets you enable the transmission of the Ethernet protocol by DMX signal to all the connected projectors. 1) Press the current setting appears on the display. 2) Use the UP and DOWN keys to select one of the following settings: - Disabled: DMX transmission disabled. - Enabled on primary: DMX transmission enabled. 3) Press to confirm the selection or LEFT to keep the current setting.
Repeat on DMX
F
B
C
F
D
Universe It lets you assign the “Universe” number to be assigned to a series of projectors. 1) Press – the current Universe address appears on the display. 2) Use the UP , DOWN , RIGHT keys to set the Universe address. 3) Press to confirm the selection or LEFT to keep the current setting.
Universe
F B F
ALPHA PROFILE 1500 & ST
D
C
E
D
Custom IP address
Custom IP address Allows you to set the IP address manually by the user default.
Custom IP mask
Custom IP mask Allows you to set manually the Subnet Mask by the user default.
17
Continue
➔
OPTIONS MENU On Option
LAMP DMX Used for enabling lamp remote control channel. 1) Press - the current settings appear on the display (On or Off). keys to enable (On) or disable (Off) the 2) Use the UP and DOWN lamp remote control channel. 3) Press to confirm the selection or LEFT to keep current settings.
Lamp Dmx Off
F
B
C
F
Pan / Tilt
Invert Pan
D
PAN / TILT Invert pan Used for reversing Pan movement. 1) Press - the current settings appear on the display (On or Off). 2) Use the UP and DOWN keys to enable (On) or disable (Off) PAN inversion. 3) Press to confirm the selection or LEFT to keep current settings.
On Off
F
B
C
F
Invert Tilt
D
Invert tilt Used for reversing tilt movement. 1) Press - the current settings appear on the display (On or Off). 2) Use the UP and DOWN keys to enable (On) or disable (Off) Tilt inversion. 3) Press to confirm the selection or LEFT to keep current settings.
On
F
Off
B
C
F
Swap Pan-Tilt
D
Swap Pan-Tilt Used for swapping Pan and Tilt channels (as well as Pan fine and Tilt fine). 1) Press - the current settings appear on the display (On or Off). 2) Use the UP and DOWN keys to enable (On) or disable (Off) Pan and Tilt channel swap. 3) Press to confirm the selection or LEFT tto keep current settings.
On
F
Off
B
C
F
Encoder Pan-Tilt
D
Encoder Pan-Tilt Used for enabling the Pan / Tilt encoders. 1) Press - the current settings appear on the display (On or Off). 2) Use the UP and DOWN keys to enable (On) or disable (Off) Pan / Tilt encoders. 3) Press to confirm the selection or LEFT to keep current settings. You can quickly disable the Pan and Tilt Encoder by simultaneously pressing the UP and DOWN keys in the ''Main Menu''.
On
F
Off
B
C
F
D
B
P/T Homing Mode
C
P/T Homing Mode Lets you set the initial projector Reset mode. 1) Press , the current setting appears on the display. 2) Use the UP and DOWN keys to select one of the following settings: Standard: Pan & Tilt are simultaneously reset. Sequenced: Tilt is reset first followed by Pan. 3) Press to confirm the selection or LEFT to keep the current setting.
Standard
F
Sequenced
B
C
F
Pan Home Def Pos Lets you assign the Pan channel “home” position at the end of Reset, without a DMX input signal. 1) Press , the current setting appears on the display. 2) Use the UP and DOWN keys to select one of the following settings: 0 degree 90 degrees 180 degrees 270 degrees (default) 3) Press to confirm the selection or LEFT to keep the current setting.
Pan Home Def Pos
F
F
ALPHA PROFILE 1500 & ST
D
18
B
C
D
Tilt Home Def Pos Lets you assign the Tilt channel “home” position at the end of Reset, without a DMX input signal. 1) Press , the current setting appears on the display. 2) Use the UP and DOWN keys to select one of the following settings: 0% 12.5% 25% 50% (default) 75% 87.5% 100% 3) Press to confirm the selection or LEFT to keep the current setting.
Tilt Home Def Pos
F
B
C
F
Color
Color Mixing
D
COLOR Color mixing Used for reversing the CMY color mixing system. 1) Press - the current settings appear on the display (On or Off). 2) Use the UP and DOWN keys select one of the following settings: RGB color mixing mode CMY color mixing mode 3) Press to confirm the selection or LEFT to keep current settings.
RGB CMY
F
B
C
F
Fixwheel Shortcut
D
Fixed wheel short-cut Used for optimizing color change time so that the disc turns in the direction that requires shorter movement. 1) Press – the current settings appear on the display (On or Off). 2) Use the UP and DOWN keys to enable (On) or disable (Off) color change optimization. 3) Press to confirm the selection, or LEFT to keep current settings.
On Off
F
B
C
F
Macro Color Adjustment
On
D
Macro color adjustment It lets you enable the overwriting of a “Macro Colour” with the Cyan, Magenta, Yellow, CTO and Colour wheel channels. Press the current setting appears on the display. 1) Use the UP and DOWN keys to enable (On) or disable (Off) the overwriting. 2) Press to confirm the selection or LEFT to keep the current setting.
Off
F
B
C
F
Shutter
Shutter On Error
D
SHUTTER Shutter on error Used for automatically closing the stop/strobe in the event of Pan/Tilt position error. 1) Press - the current settings appear on the display (On or Off). 2) Use the UP and DOWN keys to enable (On) or disable (Off) automatic stop/strobe closing in the event of Pan/Tilt position error. 3) Press to confirm the selection, or LEFT to keep current settings.
On Off
F
B
C
F
Dimmer On Shutter
D
Dimmer on Shutter Enables automatic closing of the dimmer when the strobe is completely closed. 1) Press – the current settings appear on the display (On or Off). 2) Use the UP and DOWN keys to enable (On) or disable (Off) the automatic closing of the dimmer. 3) Press to confirm the selection or LEFT to keep current settings.
On Off
F
B
C
F
Auto-focus Mode
AUTO-FOCUS MODE It lets you select the “Auto-focus Mode” from the two available. 1) Press the current setting appears on the display. 2) Use the UP and DOWN keys to select one of the following settings: Limited Zoom Range: The “Autofocus” works only in the optical run that was specifically designed for the projector in question. Complete Zoom Range: The “Autofocus” also works in overrun 3) Press to confirm the selection or LEFT to keep the current setting.
Limited Zoom Range
F
Complete Zoom Range
F
ALPHA PROFILE 1500 & ST
D
19
B
C
D
Continue
➔
MACRO EFFECTS It lets you select the “Macro Effects” from the two available. the current setting appears on the display. 1) Press and DOWN keys to select one of the following settings: 2) Use the UP
Macro Effects
F
Macro group size
B
C
Macro group size It lets you set the number of projectors to be included in the macro mode operation. 1) Press 2) Use the UP , DOWN , RIGHT keys to set the number of projectors to be included in the “Macro Effect” operation. to keep the current setting. 3) Press to confirm the selection or LEFT
F
B
C
F
Macro fixture Id
D
Macro fixture Id It lets you attribute an ID address to the projector for the phase displacement for the scene’s starting time in Macro mode. 1) Press 2) Use the UP and DOWN keys to select one of the following settings: Fixed to X. (to assign to all the projectors to be included in the Macro operation). Auto by DMX Address: According to the DMX address, it automatically detects the starting sequence of the scene in the Macro mode (to assign to all the projectors to be included in the Macro operation). to keep the current setting. 3) Press to confirm the selection or LEFT
F
B
C
F
Silent Mode
D
SILENT MODE It lets you select the “Silent Mode” from the two available. the current setting appears on the display. 1) Press 2) Use the UP and DOWN keys to select one of the following settings: Standard: Maximum speed and consequently maximum effects noise level. Quiet: reduces the speed of some effects, thereby reducing their noise level. 3) Press to confirm the selection or LEFT to keep the current setting.
Standard
F
Quiet
B
C
F
Lamp Dimming
LAMP DIMMING This lets you select the lamp “dimmer” mode, selecting one of the two available modes: • 1500W-800W: Default settings, the lamp electronically "dims” from 1500W to 800W and mechanically dims from 800W to 0. Visually, the Dimmer curve is high performance but a slight flicker is noted in some dimming positions. • 1500W-1200W: The lamp electronically “dims” from 1500W to 1200W and mechanically dims from 1200W to 0. No lamp flicker is visible when this option is selected. The "dimmer" blades are subject to higher thermal stress. Thus, more frequent "dimmer" blade maintenance may be required.
1500W800W 1500W1200W
POWER MODE Allows you to select a Power Mode from the three available. - the current settings appear on the display. 1) Press 2) Use the UP and DOWN keys to select one of the following settings: -1500-1200W Full fan speed: Lamp can change from full-power (1500W) to half-power (1200W) using the LAMP CONTROL channel. Fans always work at Full speed -1200W Low fan speed: Lamp constantly works in half-power mode (1200W) while the Fan always works at Low speed. With LAMP CONTROL channel you can only switch the lamp ON and OFF. -1500-1200W Auto fan speed: Lamp can change from full-power (1500W) to half-power (1200W) using the LAMP CONTROL channel. Automatically the fans switch from Full speed to Low speed respectively. to confirm the selection or LEFT to keep current setting. 3) Press
Power Mode
F
1500-1200 Full fan speed
1200 Low fan speed
1500-1200 Auto fan speed
F
ALPHA PROFILE 1500 & ST
D
20
B
C
D
DISPLAY Used for automatically reduce brightness on the display after about 30 seconds in idle. - the current settings appear on the display (On or Off). 1) Press keys to enable (On) or disable (Off) the 2) Use the UP and DOWN decreasing of display brightness. 3) Press to confirm the selection or LEFT to keep current settings.
On Display Off
F
B
C
F
Setting
Default Preset
SETTING Used to save 3 different settings of the items in the options menu and relative submenus. 1) Press - “Default preset” appears on the display. 2) Use the UP and DOWN keys to select one of the following configurations: - Default preset (*) - User preset 1 - User preset 2 - User Preset 3 3) Press - “Load preset X” appears on the display. 4) Use the UP and DOWN keys to select: - Load preset X to recall a previously stored configuration. - Save to preset X to store the current configuration. a confirmation message (Are you sure?) appears on the display. 5) Select YES to confirm the selection or NO to keep the current setting and return to the next higher level. (*) DEFAULT PRESET By pressing the RIGHT key and the LEFT key simultaneously once entered in the "main menu" it is possible to quickly (short cut) reset the default settings (DEFAULT PRESET). Used for restoring default values on all options menu items and relevant submenus. 1) Press , a confirmation message (Are you sure?) appears on the display. 2) Select YES to confirm the selction or NO to keep current setting. OPTION DEFAULT Lamp DMX On Invert Pan Off Invert Tilt Off Swap Pan-Tilt Off Encoder Pan-Tilt On P/T Homing Mode Standard Pan Home Def Pos 270 degrees Tilt Home Def Pos 50% Colour mixing CMY Fixed Wheel Shortcut On Macro Color Adjustment On Shutter on error Off Dimmer on Shutter Off Auto-focus mode Limited zoom range Silent mode Standard Power mode 1500-1200w full fan speed Display On
Reset To Dafault Go Back
User Preset 1
F
Load Preset 1 Save To Preset 1
User Preset 2
Load Preset 2
F
Save To Preset 2
User Preset 3
D
Load Preset 3 Save To Preset 3
B
C
B
C
E
D
F
ALPHA PROFILE 1500 & ST
21
Continue
➔
INFORMATION MENU Information
SYSTEM ERRORS Shows a list of warnings and messages relevant to errors occurred since the fixtures switching-on. 1) Pressing you are allowed to reset the SYSTEM ERRORS list. A confirmation message (Are you sure you want to clear error list ?) appears on the display. 2) Select YES to reset the list or NO to go back.
System Errors
F
Fixture Hours
FIXTURE HOURS Used for displaying projector operating hours (total and partial). 1) Press - Hours total and partial appears on the display. Total counter Counts the number of projector working life hours (from manufacture to date). Partial counter Counts the number of partial projector working life hours since the last reset to date. 2) Press to reset partial projector working hours a confirmation message (Are you sure?) appears on the display. 3) Select YES to reset partial projectors counter or NO to keep the current setting and return to the top menu level.
Total XXX Partial XXX
F
Reset...
F
Lamp Hours
LAMP HOURS Used for displaying the lamp working hours (total and partial). 1) Press - Hours total and partial appears on the display. Total counter Counts the number of projector working hours with the lamp on (from manufacture to date). Partial counter Counts the number of lamp working hours since the last reset to date. to reset partial lamp working hours, a confirmation message 2) Press (Are you sure ?) appears on the display. 3) Select YES to reset partial counter or NO to keep the current setting and return to the top menu level
Total XXX Partial XXX
F
Reset...
F
Lamp Strikes
LAMP STRIKES Used for displaying the number of times the lamp was turned on (total and partial). 1) Press - the number of times the lamp was turned on (total and partial) appears on the display. Total counter Counts the number of times the lamp was turned on (from manufacture to date). Partial counter Counts the number of times the lamp was turned on since the last reset to date. to reset partial lamp strikes hours, a confirmation message 2) Press (Are you sure ?) appears on the display. 3) Select YES to reset partial counter or NO to keep the current setting and return to the top menu level
Total XXX Partial XXX Reset...
F
F
System Version
ALPHA PROFILE 1500 & ST
Board CPU brd com.dev 0: PT-3f 1: 8-Ch 2: 6-Ch 3: 8-Ch 4: 6-Ch
Revis. x.x.x x.x x.x x.x x.x x.x. x.x.
SISTEM VERSION Used for displaying the software and hardware version of each board installed in the projector. CPU brd (CPU board) 0: PT-3f (Pan / Tilt board) 1: 8-Ch (8 channel board) 2: 6-Ch (6 channel board) 3: 8-Ch (8 channel board) 4: 6-Ch (6 channel board)
Hw.rv. x.x x.x x.x x.x x.x x.x
22
Board Diagnost.
Board 0:PT-3f 1:8-Ch 2:6-Ch 3:8-Ch 4:6-Ch
Status Good Good Good Good Good
BOARD DIAGNOSTIC Used for displaying the status error of each board installed in the projector: 0: PT-3f (Pan / Tilt board) 1: 8-Ch (8 channel board) 2: 6-Ch (6 channel board) 3: 8-Ch (8 channel board) 4: 6-Ch (6 channel board)
Err% 0.00 0.00 0.00 0.00 0.00
DMX MONITOR Used for displaying the projector DMX channel level in bit (Val) and in percentage (Perc).
Dmx Monitor
Fans Monitor
Fan Pwr.Sup Ball.In. Ball.Out Eff.In Eff.Out Lamp Lamp Gobo Board
FANS MONITOR Used for displaying the speed of each fan installed in the projector: Pwr.Sup (Power supply Fan) Ball. IN (Ballast IN Fan) Ball. Out (Ballast OUT Fan) Eff.IN (Effects IN Fan) Eff.OUT (Effects OUT Fan) Lamp (Lamp Fan) Lamp (Lamp Fan) Gobo (Gobo Fan) Board (Yoke Board Fan)
Speed (RPM) XXXX XXXX XXXX XXXX XXXX XXXX XXXX XXXX XXXX
SENSOR STATUS It lets you check the correct operations of each "sensor” installed in the projector, each channel is associated with one of the following three parameters: • n.a.= sensor not available • ON= sensor working • OFF= sensor defective
Sensor Status
NETWORK PARAMS Allows the "Network" parameters of the projector to be displayed or: IP address: Internet Protocol address (two projectors must not have the same IP address) IP mask: 255.0.0.0 Mac address: Media Access Control: the projector’s Ethernet Address.
Network params
MANUAL CONTROL Manual Control
On
LAMP Used for turning lamp on and off from the projector control panel. 1) Press - the current settings appear on the display (On or Off). 2) Use the UP and DOWN keys to turn the lamp on (On) or off (Off) 3) Press to confirm the selection or LEFT to keep current settings and return to the top level.
Lamp Off
F B F
No
D
RESET Used for resetting the projector. 1) Press to reset the projectors, a confirmation message (Are you sure ?) appears on the display. 2) Select YES to starting reset the fixture or NO to keep the current setting and return to the top menu level.
Reset Yes
F
CHANNEL Used for setting channel levels from the projector control panel. 1) Press - the first channel appears on the display. 2) Use the UP and DOWN keys to select the required channel: 3) Press and use the UP and DOWN keys to select the required DMX level (value between 0 and 255). 4) Press LEFT to return to the top menu level.
Channel
F B F D
ALPHA PROFILE 1500 & ST
C
23
C B
C
Continue
➔
TEST MENU Test
AUTOTEST Allows you to check the proper functioning of effects. 1) Press . and DOWN keys to select the required test. 2) Use the UP 3) Press to confirm the selection or LEFT to return to the top menu level.
Pan-Tilt Colour Beam Gobo All
F
F
B
C
D
Test sequence: Pan - Tilt effects (Pan & Tilt) Colour effects (CMY, colour wheel, CTO) Beam effects (Stopper-Strobe / Dimmer / Iris / Prism / Frost, Focus, Zoom, Animation disk) Gobo effects (Fixed gobo / Rotating gobo) All effects
ADVANCED MENU Advanced
Code 1234
To enable the "Advanced Menu" set up the "Access code" (1234) using the UP , DOWN , RIGHT keys. Press - "Menu advanced" appears on the display
B F
Upload Firmware
Transfer the firmware on all the connected fixtures ? Are you sure ? Yes/No
Setup Model
Changing to a wrong model may damage the fixture. Are you sure ? Yes/No
C
UPLOAD FIRMWARE Allows you to transfer the firmware from 1 fixture to all the connected fixtures. 1) Press , a confirmation message appears on the display. 2) Select YES to start the firmware loading or NO to keep the current setting and return to the top menu level
F
SETUP MODEL Allows you to change the default model of projector. 1) Press a confirmation message appears on the display. 2) Select YES to define the model of projector or NO to keep the current setting and return to the top menu level.
F
CALIBRATION Allows you to adjust effects from the control panel to obtain perfect uniformity between the projectors. 1) Press - “channels” appears on the display. 2) Using the UP and DOWN keys, select the effect you wish to regulate. 3) Press and use the RIGHT , UP and DOWN buttons to make the adjustment by setting a value between 0 and 255. 4) Press to confirm the selection or LEFT to keep current settings and return to the top level.
Calibration
F
F
F
B
C
E B
C
D
FACTORY DEFAULT Allows you to restore default values of all channels (128). 1) Press – a confirmation message appears on the display (Reset calibration to factory default ?). 2) Select YES to reset calibration to factory default or NO to keep the current setting and return to the top menu level.
Factory Default
F
ALPHA PROFILE 1500 & ST
E
24
MAINTENANCE 11
12
3
1
2 2 1
1/4 Turn
4
1
1/4 Turn
5
Locking and releasing Pan and Tilt movements - Refer to the instructions in the UNPACKING AND PREPARATION section. Opening the head covers - Fig. 11. Closing the head covers - Fig. 12.
ALPHA PROFILE 1500 & ST
25
Continue
➔
13
14
1
1 2 Lamp change - Fig 14 Take the new lamp out of its package and insert in the fitting. WARNING: do not touch the lamp’s envelope with bare hands. Should this happen, clean the bulb with a cloth soaked in alcohol and dry it with a clean, dry cloth.
2
15
Lamp regulation - Fig. 15 To centre the lamp, turn the three adjusting screws as shown in the figure. CAUTION: Fast lamp ON-OFF cycles (for example 10 minutes ON / 10 minutes OFF) will reduce the lamp life.
Opening and closing lamp compartment - Fig. 13
16
Lower Side
1
2
Fan support plate opening and closing (Lower side) - Fig. 16 ALPHA PROFILE 1500 & ST
26
17
Upper Side
1
2
Fan support plate opening and closing (Upper side) - Fig. 17
18
Lower Side
2
1
085908/001
085904/001
085912/001
085906/001
085907/001
085903/001
085911/001
085901/001
Replacing fixed gobos (ø 31.5 mm - max 25 mm image - thickness max 1 mm) - Fig. 18 IMPORTANT: Please contact CLAY PAKY before using customized gobos. ALPHA PROFILE 1500 & ST
27
Continue
➔
19
Lower Side
1
2
Bearing group replacement - Fig. 19
20 GOBO ROTATION
1
084630/001
105115/802
2
084632/001
084625/001
084626/001 GOBO INDEX
084628/001
Replacing rotating gobos (ø 37.5 mm - max 25 mm image – thickness 1 mm) - Fig. 20 IMPORTANT: Please contact CLAY PAKY before using customized gobos. IMPORTANT: Use only glass gobos on the rotating gobos wheels.
21
COATED GLASS GOBOS TYPE 1
COATED GLASS GOBOS TYPE 2 Coated side towards lamp
Grey/Black side away from lamp
Coated side
Uncoated side Reflective side towards lamp
Uncoated side To determine which side of a godo is coated, hold an odject up to it. On the uncoated side, there is a space between the object and its reflection.
Gobo orientation - Fig. 21 The pictures shown the correct gobos orientation. ALPHA PROFILE 1500 & ST
28
22 Upper Side
Lower Side
Periodical cleaning - Fig. 22 To ensure optimal operation and performance for a long time it is essential to periodically clean the parts subject to dust and grease deposits. The frequency with which the following operations are to be carried out depends on various factors, such as the amount of the effects and the quality of the working environment (air humidity, presence of dust, salinity, etc.). Use a soft cloth dampened with any detergent liquid for cleaning glass to remove the dirt from the reflectors, from the lenses and filters. It is recommended that the projector undergoes an annual service by a qualified technician for special maintenance involving at least the following operations: • General cleaning of internal parts. • Restoring lubrication of all parts subject to friction, using lubricants specifically supplied by Clay Paky. • General visual check of the internal components, cabling, mechanical parts, etc. • Electrical, photometric and functional checks; eventual repairs.
23 1
Thermostat
2
7
Lower Side
3
6 4
5
Extraction of the effect modules: Preliminary operations - Fig. 23
ALPHA PROFILE 1500 & ST
29
Continue
➔
24
Lower Side
7
6
1 2 8 4
9
5
3
Upper Side
Upper Side
14 11 10
12 13
Extraction of the effect modules - Fig. 24 IMPORTANT: Grasp the modules using the support structure and not the details which could get damaged. Insertion of the effect modules: Repeat the operations indicated in Fig. 24 and 25 in reverse order
ALPHA PROFILE 1500 & ST
30
25 Lower Side
Upper Side
5 3
1
2
4
Upper Side
5
Upper Side
2
1
4 3
Extraction of the effect modules - Fig 25 IMPORTANT: Grasp the modules using the support structure and not the details which could get damaged. Insertion of the effect modules: Repeat the operations indicated in Fig. 24 and 25 in reverse order
ALPHA PROFILE 1500 & ST
31
Continue
➔
26
2 1
3
6
5
4
Battery removal - Fig. 26 This product contains a rechargeable lead-acid or lithium iron tetraphosphate battery. To preserve the environment, please dispose the battery at the end of its life according to the regulation in force. LiFePO4 Pb
ALPHA PROFILE 1500 & ST
32
TECHNICAL INFORMATION Power supplies available 200-240V 50/60Hz 740 (29.13")
Input power 2000VA a 230V 50Hz.
Safety Devices • Bipolar circuit breaker with thermal protection. • Automatic break in power supply in case of overheating or failed operation of cooling system.
Total output Profile 1500: Max 27000 lumens. Profile 1500 ST: 24400 lumens.
628 (24.72")
660 (25.98")
Lamp Discharge lamp. Type HTI 1500W/60/P50-L Lok-it Osram (L10102) - Cap PGJ50 - Colour temperature 6000 K - Luminous flux 135000 lm - Average life 750 h - Any working position
Cooling Forced ventilation with axial fans.
Motors 31 stepper motors, operating with microsteps, totally microprocessor controlled.
Working position Functioning in any position.
Body • Aluminium structure with die-cast plastic cover. • Two side handles for transportation. • Device locking PAN and TILT mechanisms for transportation and maintenance.
Weights 50.35 Kg (110lbs, 12ozs).
Optical unit Elliptic reflector with high luminous efficiency
232 (9.13")
Channels Max 41 control channels.
843 (33.19")
Inputs • DMX 512 • Ethernet
500 (19.69")
Movable body • Movement by means of two stepper motors, controlled by microprocessor. • Automatic repositioning of PAN and TILT after accidental movement not controlled by control unit. • Travel: - PAN = 540° - TILT = 252° • Maximum speeds: - PAN = 4.0 sec (360°) - TILT = 3.2 sec (252°) • Resolution: - PAN = 2.11° - PAN FINE = 0.008° - TILT = 0.98° - TILT FINE = 0.004°
480 (18.90")
488 (19.21")
IP20 protection rating • Protected against the entry of solid bodies larger than 12mm (0.47”). • No protection against the entry of liquids.
CAUSE AND SOLUTION OF PROBLEMS THE PROJECTOR WILL NOT SWITCH ON ELECTRONICS NON-OPERATIONAL
PROBLEMS
DEFECTIVE PROJECTION REDUCED LUMINOSITY
POSSIBLE CAUSES No mains supply. Lamp exhausted or defective. Signal transmission cable faulty or disconnected. Incorrect addressing. Fault in the electronic circuits. Lenses or reflector broken Dust or grease deposited.
ALPHA PROFILE 1500 & ST
CHECKS AND REMEDIES Check the power supply voltage. Replace the lamp. (See instructions). Replace the cables. Check addresses (see instructions). Call an authorised technician. Call an authorised technician. Clean (see instructions).
33
CHANNEL FUNCTION NB: To prevent accidental breakage of the effects, which could collide with each other during transport, before switching the projector OFF check that all the projector Channels have been excluded (DMX level = 0%).
ALPHA PROFILE 1500 CHANNEL MODE
CHANNEL
STANDARD
VECTOR
1
CYAN
CYAN
2
MAGENTA
MAGENTA
3
YELLOW
YELLOW
4
C.T.O
C.T.O
5
COLOUR WHEEL
COLOUR WHEEL
6
MACRO COLOURS
MACRO COLOURS
7
STOP/STROBE
STOP/STROBE
8
DIMMER
DIMMER
9
DIMMER FINE
DIMMER FINE
10
IRIS
IRIS
11
STATIC GOBO CHANGE
STATIC GOBO CHANGE
12
ROTATING GOBO CHANGE
ROTATING GOBO CHANGE
13
GOBO ROTATION
GOBO ROTATION
14
GOBO FINE
GOBO FINE
15
ROTATING PRISM CHANGE
ROTATING PRISM CHANGE
16
PRISM ROTATION
PRISM ROTATION
17
FROST INSERTION
FROST INSERTION
18
BLADE UP1
BLADE UP1
19
BLADE UP2
BLADE UP2
20
BLADE DW1
BLADE DW1
21
BLADE DW2
BLADE DW2
22
BLADE RG1
BLADE RG1
23
BLADE RG2
BLADE RG2
24
BLADE LF1
BLADE LF1
25
BLADE LF2
BLADE LF2
26
FRAMING ROTATION
FRAMING ROTATION
27
FOCUS
FOCUS
28
FOCUS FINE
FOCUS FINE
29
ZOOM
ZOOM
30
AUTOFOCUS DISTANCE
AUTOFOCUS DISTANCE
31
AUTOFOCUS ADJUSTMENT
AUTOFOCUS ADJUSTMENT
32
MACRO EFFECTS
MACRO EFFECTS
33
PAN
PAN
34
PAN FINE
PAN FINE
35
TILT
TILT
36
TILT FINE
TILT FINE
37
FUNCTION
FUNCTION
38
RESET
RESET
39
LAMP CONTROL (with Option "Lamp DMX" ON)
LAMP CONTROL (with Option "Lamp DMX" ON)
40
PAN-TILT TIME
41
COLOUR TIME
42
BEAM TIME
43
GOBO TIME
ALPHA PROFILE 1500 & ST
34
NOTE: On conclusion of resetting in case of absence of DMX signal, Pan & Tilt move to the "Home" position (Pan 128 bit - Tilt 128 bit) all the others channels stay at 0 bit. • COLOUR MIXING - channel 1 - 2 - 3
• MACRO COLOURS - channel 6
Operation with option color mixing: RGB CHANNEL 1
CHANNEL 2 CHANNEL 3
BIT 255
CYAN
MAGENTA
YELLOW
0
COLOR NAME
EFFECT
Unused Range Half CT straw Lighter blue Glacier blue Fuschia pink Mallard green Jade 3/4 CT Orange 3/4 CTB Half minus green Minus green 1/4 CTO 1/2 CTO Full CT Orange 1/4 CTB 1/2 CTB Full CTB Alice Blue Congo Blue Dark Lavender Chrome Orange Lagoon blue Deep Lavender Liliac tint Daylight Blue Flame red Bastard amber Deep Orange Pink Pale rose Pale Gold Bright rose Apricot Bright Blue Primary green Light green Pale green Special Lavender Pale Lavender Deep golden amber Golden amber Medium blue Marine blue Bright pink Mauve Fern Green Leaf green Deep Blue Dark blue Light blue Steel blue Medium blue green Peacock blue Dark pink Light Salmon English rose Light rose Primary red Orange Deep amber Straw Light amber Yellow Spring yellow Dark Yellow Green Lime green Just Blue Tokyo Blue Sky blue Pale blue Lavender Bright Red Med Yellow Med bastard amber Random Macro Color (only for Macro effects) Unused Range
COLOUR INSERTED
IMPORTANT: The lamp dim to half power 1 second after all the 3 channels stay at 0 bit level. The lamp goes back to full power when the channels level is put higher than 0 bit. Operation with option color mixing: CMY CHANNEL 1 CHANNEL 2 CHANNEL 3
CYAN
MAGENTA
YELLOW
BIT
EFFECT
255
COLOUR INSERTED
0
COLOUR EXCLUDED
IMPORTANT: The lamp dim to half power 1 second after all the 3 channels stay at 255 bit level. The lamp goes back to full power when the channels level is put lower than 255 bit. • C.T.O. - channel 4 CHANNEL 4
CTO
BIT
EFFECT
255
FILTER INSERTED
0
FILTER EXCLUDED
• COLOUR WHEEL - channel 5 BIT
ALPHA PROFILE 1500 & ST
BIT 148-255 146-147 144-145 142-143 140-141 138-139 136-137 134-135 132-133 130-131 128-129 126-127 124-125 122-123 120-121 118-119 116-117 114-115 112-113 110-111 108-109 106-107 104-105 102-103 100-101 98-99 96-97 94-95 92-93 90-91 88-89 86-87 84-85 82-83 80-81 78-79 76-77 74-75 72-73 70-71 68-69 66-67 64-65 62-63 60-61 58-59 56-57 54-55 52-53 50-51 48-49 46-47 44-45 42-43 40-41 38-39 36-37 34-35 32-33 30-31 28-29 26-27 24-25 22-23 20-21 18-19 16-17 14-15 12-13 10-11 8-9 6-7 4-5 2-3
ROSCO CODE 442 353 352 345 325 323 285 281 248 247 206 205 204 203 202 201 197 181 180 179 172 170 169 165 164 162 158 157 154 152 148 147 141 139 121 138 137 136 135 134 132 131 128 126 122 121 120 119 118 117 116 115 111 109 108 107 106 105 104 103 102 101 100 90 88 79 71 068 063 058 026 010 004
LEE CODE 442 353 352 345 325 323 285 281 248 247 206 205 204 203 202 201 197 181 180 179 172 170 169 165 164 162 158 157 154 152 148 147 141 139 121 138 137 136 135 134 132 131 128 126 122 121 120 119 118 117 116 115 111 109 108 107 182 105 104 103 102 101 100 90 88 79 71 068 063 058 026 010 004
CYAN BIT 0 226 220 109 255 127 0 85 60 60 62 25 0 75 85 94 236 251 195 0 224 100 41 210 0 0 0 0 0 0 0 0 182 0 0 105 97 73 0 0 255 60 0 0 173 136 255 255 245 167 189 136 0 50 0 0 0 0 0 58 0 0 80 255 118 255 255 245 122 165 0 48 0
1
-
-
-
-
0
-
-
-
-
COLOUR EXCLUDED
EFFECT
255
FAST ROTATION 160 rpm
128
SLOW ROTATION 0.2rpm
117
BLUE
97
ORANGE
77
AQUAMARINE
58
GREEN
39
PINK
20
RED
0
WHITE
35
MAGENTA YELLOW BIT BIT 0 34 0 149 0 129 186 77 0 0 0 162 36 61 79 87 19 86 71 86 71 123 26 45 44 58 54 91 71 84 79 80 51 0 241 0 170 0 98 255 0 121 129 77 59 39 73 105 255 227 26 0 148 255 159 0 48 0 60 98 255 0 81 55 0 99 0 0 0 255 0 179 105 72 102 44 255 255 142 234 152 127 0 106 255 0 255 0 0 235 0 241 229 58 161 0 0 145 0 141 0 157 0 128 139 0 121 58 62 0 95 0 0 0 182 255 26 199 17 104 0 171 0 255 0 227 0 255 0 241 77 0 255 0 77 64 0 112 186 77 255 0 0 239 62 78
CTO BIT 190 138 138 120 236 0 217 54 75 75 122 131 234 109 89 0 205 255 160 255 40 120 120 88 255 199 255 255 189 138 255 255 92 231 0 100 90 120 255 110 0 73 197 255 89 64 128 0 138 165 91 91 220 230 247 220 0 76 223 176 193 149 157 204 124 204 180 173 127 0 255 115 159
WHEEL BIT 0 0 0 0 58 77 0 0 39 39 0 0 0 0 0 0 0 0 0 0 79 0 0 0 97 0 0 0 0 0 0 0 77 58 77 0 0 0 0 0 77 77 0 74 0 0 77 77 0 0 77 77 0 0 0 0 20 0 0 0 0 0 0 0 0 0 77 0 0 0 21 0 0
-
-
-
-
-
-
Continue
➔
• STATIC GOBO CHANGE - channel 11 BIT
EFFECT
252 - 255 239 - 251 226 - 238 213 - 225 208 - 212 207
OPEN RANDOM FAST STROBE RANDOM MEDIUM STROBE RANDOM SLOW STROBE OPEN FAST PULSATION
108 104 - 107 103
4 0-3
MACRO
MACRO
• STOP / STROBE - channel 7
SLOW PULSATION OPEN FAST STROBE (12 flash/sec)
SLOW STROBE (1 flash/sec) CLOSED
IMPORTANT: The lamp dim to half power 1 second after the channel stay at 0 bit level. The lamp goes back to full power when the channel level is put higher than 0 bit. • DIMMER - channel 8 BIT
BIT
EFFECT
255
GOBO 8 SHAKE, FAST SPEED
244 243
GOBO 8 SHAKE, SLOW SPEED GOBO 7 SHAKE, FAST SPEED
232 231
GOBO 7 SHAKE, SLOW SPEED GOBO 6 SHAKE, FAST SPEED
220 219
GOBO 6 SHAKE, SLOW SPEED GOBO 5 SHAKE, FAST SPEED
208 207
GOBO 5 SHAKE, SLOW SPEED GOBO 4 SHAKE, FAST SPEED
196 195
GOBO 4 SHAKE, SLOW SPEED GOBO 3 SHAKE, FAST SPEED
184 183
GOBO 3 SHAKE, SLOW SPEED GOBO 2 SHAKE, FAST SPEED
172 171
GOBO 2 SHAKE, SLOW SPEED GOBO 1 SHAKE, FAST SPEED
160 159
GOBO 1 SHAKE, SLOW SPEED FAST ROTATION (100 rpm)
EFFECT
255
0
The lamp is linearly dimmed from full power to half power electronicaly and mechanically from half power to off.
118 114 - 117 113
SLOW ROTATION (5 rpm) STOP SLOW ROTATION (5 rpm)
72
FAST ROTATION (100 rpm)
64 - 71
GOBO 8
56 - 63
GOBO 7
48 - 55
GOBO 6
40 - 47
GOBO 5
32 - 39
GOBO 4
24 - 31
GOBO 3
16 - 23
GOBO 2
8 - 15
GOBO 1
0-7
WHITE
• ROTATING GOBO CHANGE - channel 12
• DIMMER FINE - channel 9 BIT
EFFECT
MACRO
255
BIT
EFFECT
255
GOBO 6 SHAKE, FAST SPEED
235 234
GOBO 6 SHAKE, SLOW SPEED GOBO 5 SHAKE, FAST SPEED
214 213
GOBO 5 SHAKE, SLOW SPEED GOBO 4 SHAKE, FAST SPEED
193 192
GOBO 4 SHAKE, SLOW SPEED GOBO 3 SHAKE, FAST SPEED
172 171
GOBO 3 SHAKE, SLOW SPEED GOBO 2 SHAKE, FAST SPEED
151 150
GOBO 2 SHAKE, SLOW SPEED GOBO 1 SHAKE, FAST SPEED
130 112-129
GOBO 1 SHAKE, SLOW SPEED GOBO 6
93-111
GOBO 5
75-92
GOBO 4
56-74
GOBO 3
38-55
GOBO 2
19-37
GOBO 1
0-18
WHITE
0
MACRO
• IRIS - channel 10 BIT
EFFECT
252 - 255 251
MAXIMUM APERTURE FAST PULSATION, FAST CLOSING
212 211
SLOW PULSATION, FAST CLOSING FAST PULSATION, FAST OPENING
172 171
SLOW PULSATION, FAST OPENING FAST PULSATION
132 128 - 131
0
ALPHA PROFILE 1500 & ST
SLOW PULSATION MAXIMUM APERTURE
MINIMUM APERTURE
36
• GOBO ROTATION - channel 13
STOP
540°
360°
0°
• FROST - channel 17 BIT
EFFECT
255
FAST ROTATION (150 rpm)
193 191 - 192 190
SLOW ROTATION (2,2 rph) STOP SLOW ROTATION (2,2 rph)
128 127
FAST ROTATION (150 rpm) 540° POSITION
105
450° POSITION
84
360° POSITION
63
270° POSITION
42
180° POSITION
21
90° POSITION
0
0° POSITION
BIT
• GOBO FINE - channel 14
EFFECT
255
FROST INSERTED
0
FROST EXCLUDED
• BLADE UP 1 - channel: 18
BIT
BIT
255
255
EFFECT BLADE IN
127 127
0
BLADE OUT
0
• BLADE UP 2 - channel: 19
• PRISM INSERTION - channel 15
BIT
BIT
EFFECT
255
255
EFFECT BLADE IN
PRISM INSERTED
127
128 127
PRISM EXCLUDED
0
BLADE OUT
0
• BLADE DW 1 - channel: 20
• PRISM ROTATION - channel 16 BIT
EFFECT
255
FAST ROTATION (120 rpm)
BIT 255
193 191 - 192 190
STOP
128 127
540°
360°
0°
ALPHA PROFILE 1500 & ST
EFFECT BLADE IN
SLOW ROTATION (3 rph) STOP SLOW ROTATION (3 rph)
127
FAST ROTATION (120 rpm) POSITION 540°
105
POSITION 450°
84
POSITION 360°
63
POSITION 270°
42
POSITION 180°
21
POSITION 90°
0
POSITION 0°
0
37
BLADE OUT
Continue
➔
• BLADE DW 2 - channel: 21
• BLADE LF 2 - channel: 25 BIT 255
BIT
EFFECT
255
BLADE IN
127
127
0
EFFECT BLADE IN
0
BLADE OUT
BLADE OUT
Important: The lamp automatically dim to half power in any condition in which the blades completely shut the light beam.
• BLADE RG 1 - channel: 22
• FRAMING ROTATION - channel: 26
BIT 255
EFFECT
BIT
BLADE IN
255
127
0
127
0
BLADE OUT
• BLADE RG 2 - channel: 23
• FOCUS - channel 27 BIT
BIT 255
255
EFFECT
EFFECT NEAR
BLADE IN
127
0
BLADE OUT 0
• BLADE LF 1 - channel: 24
DISTANT
• FOCUS FINE - channel 28 BIT
BIT 255
EFFECT
255
EFFECT NEAR
BLADE IN
127
0
BLADE OUT 0
ALPHA PROFILE 1500 & ST
38
DISTANT
• ZOOM - channel: 29
• PAN - channel 33 Operation with option InvertPan Off (Tilt conventionally represented at 35 bit and option Invert Tilt
G
BIT 255
EFFECT NARROW BEAM
GOff)
BIT 255
WIDE BEAM
0
0
G
• AUTOFOCUS DISTANCE - channel 30 AUTOFOCUS priority: 1 - Blades 2 - Rotating Gobo 3 - Static Gobo 4 - Iris
Operation with option InvertPan On (Tilt conventionally represented at 35 bit and option Invert Tilt BIT 255
GOff)
EFFECT BIT
100 METRES
255
128
50 METRES
102
40 METRES
77
30 METRES
51
20 METRES
26
10 METRES
7
3 METRES
0-6
0
AUTOFOCUS OFF
• AUTOFOCUS ADJUSTMENT - channel 31 BIT 255
• PAN FINE - channel 34 Operation with option InvertPan Off (Tilt conventionally represented at 35 bit and option Invert Tilt
G
EFFECT
GOff)
FOCUS FINE
BIT 255
128
0
FOCUS FINE 0
G
Operation with option InvertPan On (Tilt conventionally represented at 35 bit and option Invert Tilt
• MACRO EFFECTS - channel 32 BIT 232-255
STAND BY BLACK
220-231
RANDOM MACRO 8
208-219
RANDOM MACRO 7
196-207
RANDOM MACRO 6
184-195
RANDOM MACRO 5
172-183
RANDOM MACRO 4
160-171
RANDOM MACRO 3
148-159
RANDOM MACRO 2
136-147
RANDOM MACRO 1
112-135
STAND BY BLACK
100-111
MACRO 8
88-99
MACRO 7
76-87
ALPHA PROFILE 1500 & ST
BIT 255
MACRO 6
64-75
MACRO 5
52-63
MACRO 4
40-51
MACRO 3
28-39
GOff)
EFFECT
MACRO 2
16-27
MACRO 1
12-15
STAND BY BLACK
8-11
STAND BY
0-7
MACRO OFF
0
39
Continue
➔
• FUNCTION - channel: 37
• TILT - channel 35 Operation with option Invert Tilt Off (Pan conventionally represented at 0 bit and option Invert Pan
G
GOff)
BIT
EFFECT
255
BIT 255
SE
UNUSED RANGE
L
TX D MX
S
E
63 51-62
LINEAR (Default)
38-50
CONVENTIONAL
25-37
NORMAL
12-24
FAST (Default)
DIMMER CURVE FUNCTION
128
SEL
TX DMX
S
E
0-11
TX DMX
E
G
• RESET - channel: 38
Operation with option Invert Tilt On (Pan conventionally represented at 0 bit and option Invert Pan
GOff)
BIT 255
BIT
EFFECT COMPLETE RESET Complete reset is activated passing throug the unused range and staying 5 seconds in complete reset levels.
255
128 127
SEL
TX DMX
S
UNUSED RANGE
The functions are actived passing through unused range and staying 5 seconds in necessary level.
0 SEL
S
PAN-TILT FUNCTION
E
COMPLETE RESET PAN / TILT RESET Pan / Tilt reset is activated passing throug the unused range and staying 5 seconds in Pan / Tilt reset levels.
128
77 76
Effects reset is activated passing throug the unused range and staying 5 seconds in Effects reset levels.
S EL TX DMX
S
PAN / TILT RESET EFFECTS RESET
E
26 25
EFFECTS RESET UNUSED RANGE
0 0
The functions are actived passing through unused range and staying 5 seconds in necessary level.
SEL TX DMX
S
E
• TILT FINE - channel 36 Operation with option Invert Tilt Off (Pan conventionally represented at 0 bit and option Invert Pan
G
• LAMP CONTROL (only with option LAMP DMX On) - channel: 39
GOff)
IMPORTANT: Alpha Profile 1500 is not provided with hot restrike igniter
BIT
BIT
255
255
ON
EFFECT LAMP ON (1500W)
Lamp ignition after 5 s in full power levels. Immediate transition from half to full power.
SE
L
TX DMX
S
E
ON ON
180 179
LAMP ON (1500W) LAMP ON (1200W)
Immediate transition from full to half power. Lamp ignition not allowed in half power.
ON OFF
101 100
LAMP ON (1200W) LAMP OFF Lamp switch off passing throug the unused range and staying 5 s in Lamp OFF levels.
OFF 0
SEL
26 25 0
TX
LAMP OFF UNUSED RANGE
DMX
S
E
G
The functions are actived passing through unused range and staying 5 seconds in necessary level.
Operation with option Invert Tilt On (Pan conventionally represented at 0 bit and option Invert Pan
GOff)
BIT 255
SEL
TX DMX
S
E
S
E
SEL
TX DMX
ALPHA PROFILE 1500 & ST
0
40
TIMING CHANNELS
Timing Channel
Channel function
40
Pan - Tilt time
Pan – Tilt – Pan Fine – Tilt Fine
41
Colour time
Cyan - Magenta - Yellow – C.T.O. – Color wheel
42
Beam time
Dimmer – Zoom – Focus – Frost/Prism – Iris - Framing Rotation
43
Gobo time
Fix Gobo –Rotating Gobo change
TIME TABLE
BIT 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
Seconds Full 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 2.2 2.4 2.6 2.8 3 3.2 3.4 3.6 3.8 4 4.2 4.4 4.6 4.8 5 5.2 5.4 5.6 5.8 6 6.2 6.4 6.6 6.8 7 7.2 7.4 7.6 7.8 8 8.2 8.4
ALPHA PROFILE 1500 & ST
BIT 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85
Seconds 8.6 8.8 9 9.2 9.4 9.6 9.8 10 10.2 10.4 10.6 11 12 13 14 15 16 17 18 19 20
21 22 23
BIT 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128
Seconds
BIT 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171
24 25 26 27 28 29
30 31 32 33 34 35 36 37 38
39 40
41
Seconds 41 42 43 44 45 46 47 48 49
50 51 52 53 54 55 56 57
BIT 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215
Seconds 58
59 60 65 70 75 80 85 90 95 100 110
120 130 140 150
BIT 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255
160
Seconds 170 180 190 200
210 220 230 240 250 260 270 280 290 300
310 Follow cue Data
IST00F/001 – EN - Rev.D 05/2015
CLAY PAKY S.p.A. - Via Pastrengo, 3/b - 24068 Seriate (BG) Italy - Tel. +39-035-654311 - Fax +39-035-301876 - www.claypaky.it