Transcript
HSB Battery Charger Part #100482 This automatic battery charger is an intelligent module which maintains lead acid batteries at a full charge, when the HSB has been properly installed. Continual monitoring and maintenance will promote long battery life. In accordance with the principle of high efficiency, at Full Load, >85% of efficiency is achieved. This charger is a maintenance battery charger. If the battery voltage falls below 6V, the charger will not re-change the batteries. To properly maintain battery efficiency you must follow the battery manufacturer’s safety instructions, warnings and proper maintenance procedures. Feature benefits include: reverse polarity protection, short circuit protection, overload protection, over voltage, over current, floating charging system, constant voltage output and a rugged design for industrial environments. This charger is for lead acid batteries only. All adjustments are preset at the factory. The automatic battery charger has five (5) built in LEDs that display the following, viewing from left to right:
Power Small Bar Middle Bar Large Bar
No Charge
Lit to indicate the battery is fully charged. Lit to indicate the battery is receiving a trickle charge. Lit to indicate current output is near 50%. Lit to indicate the charger is operating above 50% capacity. Lit to indicate a battery charging problem. If this LED is lit, the LED on the Engine Controller module, “LOW BATTERY” will also be lit.
The battery(s) might be discharged to a level that is too low to re-charged with this charger (battery voltage below 6V). If this is the case, the batteries will need to be charged individually. Remove all battery cables from the batteries and follow the battery manufacturers’ instructions on properly servicing/charging the batteries. Be careful to avoid corrosion on the battery post(s). Corrosion can have the effect of creating an insulation between the post(s) and the cable(s), this will severely affect the performance of the battery. Follow battery manufacturers’ instructions on proper maintenance, service or replacement. The correct wire lands are read left to right, 6 land points: Wire Land #1
Ground
G (Green)
Wire Land #2
L1
P (Pink)
Wire Land #3
N
W (White)
Wire Land #4
Not Connected
Empty
Wire Land #5
B-
B (Black)
Wire Land #6
B+
R (Red)
Champion Power Equipment 12039 Smith Ave. Santa Fe Springs, CA 90670 "MANY PRETENDERS, SOME CONTENDERS, ONE CHAMPION"